CARRIN ELECTRONICS KW9177T THERMO SENSOR User Manual

CARRIN ELECTRONICS COMPANY LIMITED THERMO SENSOR

User manual

KW9075RFwithoutdoorcableprobe  WWVB1.Features:zRadiocontrolledclockwithWWVBsignal.z433MHzRFreceivingfrequency.zPerpetualCalendarUptoYear2099.z12/24Hourtimedisplayselectable.zDailysnoozealarmfunctionzIndoorTemperaturemeasurement:range32F~122FOutdoorTemperaturemeasurement:range58F~+158F2.MainUnitAppearance:PARTA: A1:RadioControlledTime.A2:RadioControlledIconA3:AlarmIconA4:SecondA5:IndoorTemperatureA6:Date&DayofWeekA7:OutdoorTemperaturePARTB:B1:“SNOOZE”ButtonB2:“+/12/24”ButtonB3:“MODE/SET”ButtonB4:“/C/F/  “ButtonB5:“RESET”ButtonB6:“ALON/OFF”ButtonB7:“ALERT”ButtonB8:“SEARCH”ButtonPARTC433.92MHz RF receiving frequency.
C1:WallMountHole C2:BatteryCompartmentCover C3:Stand3.OutdoorSensorAppearance. D1:TransmissionIndicationLEDD2:OutdoorTemperatureD3:BatteryCompartmentD4:WallMountHoleD5:“RESET”button D6:°C/°F”button D7:StandD8:Cableprobe4.GettingStarted:4.1MainUnit:zOpenmainunitbatterycompartmentcover[C2]zInsert3xCsizebatteriesobservingpolarity[“+”and“–“marks]zReplacemainunitbatterycompartmentcover[C2]zUseapintopresstheRESET[B5]buttonontherearofthemainunit,themainunitisnowreadyforuse4.2OutdoorThermoSensorzBattery compartment (D3) of thermo sensor is locating behind the back cover,unscrewsthebatteriescovertoopen.zInsert2xAAAbatteriesobservingpolarity[“+”and“–“marks]5.Installation5.1MainUnitThemainunitcanbeplacedontoanyflatsurface(C3),orwallmountedbythehanginghole(C1)atthebackoftheunit. 
5.2OutdoorThermosensorTheremotesensorshouldbesecurelymountedontoahorizontalsurface. Note:Transmissionsbetweenreceiverandtransmittercanreachupto100minopenarea.  OpenArea:therearenointerferingobstaclessuchasbuildings,trees,vehicles,highvoltagelines,etc.6.RFTransmissionzThemainunitautomaticallystartsreceivingtransmissionfromoutdoorthermosensorforoutdoortemperatureafterbatteriesinserted.RFicon“ ”flashesontheLCD.zThe thermo sensor unit will automatically transmit temperature signal to themainunitafterbatteriesinserted. zIfmainunitfailedtoreceivetransmissionfromoutdoorthermosensorinfirst3minutesafterthebatteriesinserted,“.–”displayontheLCD.zHold“SEARCH”button(B8)for3secondstoreceivetransmissionmanually. zPress “C/F” button (D5) on thermo sensor unit to select temperature to bedisplayedinCelsiusmodeorFahrenheitmode.7.TimeandAlarmSetting7.1RadioControlledClock:zAfter batteries inserted and main unit finishes receiving the transmission fromoutdoor thermo sensor, the clock automatically starts to scan the WWVB timesignal.RadioControlIcon“ ”flashesontheLCD.flashes,IndicatingnowisreceivingWWVBsignalturnson,Indicatingsignalreceivedsuccessfully disappear,IndicatingsignalreceptionfailedzTheclockautomaticallyscansthetimesignalat2.00a.m.everydaytomaintainaccurate timing. If reception fail, scanning stops (“ ” on LCD disappear) andrepeatsagainat3.00a.m.,4.00a.m.and5.00am.zTheclockcanbesettoscanthetimesignalmanuallybyholding“  ”button(B4)for 3 seconds. Each reception takes around several minutes. If receptions fail,scanningstops.(“ ”onLCDdisappear)andrepeatsagainonnextfullhour.E.g.scanningfailedat8:20a.m.Itwillscanagainat9:00a.m.
zStopscanningbyholding“ ”button(B4)for3seconds.7.2ManualTimeSetting:zIn time display mode, hold “MODE” button (B3) for 3 seconds to enterClock/CalendarsettingMode.zPress“+”(B2)or“”(B4)buttontoadjustthesettingandpress“MODE”button(B3)toconfirmeachsetting.(Bykeepingthe“+”(B2)or“”(B4)buttonpressed,couldacceleratetheprocessandreachthedesiredvaluemorequickly)zThesettingsequenceisshownasfollow:Hour,Minute,Second,Year,Month/Daysequence,Month,Date,DSTNote: (1) All Setting mode will automatically exit in around 15 seconds without anyadjustment(2) For Time Zone: the default setting is zone “E”. By holding “+” (B2) button for 3secondstoadjusttootherzones“P”“M”or“C”.(3) DST:WhenDSTfunctionisactivated,andit’sinDaylightSavingMode(RCCsignalwithDST)“DST”wouldbeshownontheLCD.7.3DailyAlarmFunction:zPress “MODE” button (B3) to select to view alarm Time, “AL” shown on thedisplayzWhenviewingtheAlarmTime,hold“MODE”button(B3)for3secondstoenterAlarm Time setting. Press “+” (B2)or “” (B4) button to adjust thealarm time.Press“MODE”button(B3)toconfirmthesetting.7.4SnoozeAlarmFunction:zPress“ALON/OFF”Button(B6)toactivateordeactivatethealarm.Ifthealarmison,alarmicon"  "appearsonthedisplay.zWhenalarmalerts,except“SNOOZE”button,pressanybuttontostopthealarm.Otherwise, the alarm signal sounds for about2 minutes, then stopsautomatically.zPress“SNOOZE”(B1)buttonwhenalarmalerts.Thealarmsnoozesforaround5minutes, then it alerts again. “ ” flashes on the LCD during the snooze time.Thisprocesscanberepeated7times. 7.5  12/24HourDisplaymode:
zPress“12/24”(B2)buttontoselect12or24hoursmode. 8.Thermometer8.1TemperaturedisplayzPress “°C/°F” (B4) button to select Temperature in Celsius mode/ Fahrenheitmode.zIf the temperature is out of the measurable range, LL.L (beyond the minimumtemperature)orHH.H(beyondthemaximumtemperature)willbeshownontheLCD.8.2TemperatureAlertfunctionzPress“ALERT”button(B7)tosettheOutdoorTemperatureAlertfunction onoroff,“ ”appearsontheLCDiftemperaturealertfunctionisactivated.zHold “ALERT” button (B7) for 3 seconds to enter outdoor temperature alertsetting,upperlimiticon“ ”flashonthedisplay.zPress“+”(B2)or“”(B4)buttontosettheupper” ”andlower“ ”limitoftheoutdoortemperature.Press“ALERT”button(B7)toconfirmthesetting.9. The use of temperature probe zInsert the probe plug (D8) to the jack on the right hand side of the ThermoSensorUnit.zPuttheprobeoutsideandleavethethermosensorunitinindoorareatoavoidfreezingupthebatterywhentheoutdoortemperatureisbelow4F.Alwaysusethetemperatureprobetosensethetemperaturewhenthetemperatureisbetweenthefollowingrange:58F~4Fand+122F~+158F10.Low battery indication: Thelowbatteryicon“ ”turns onthe display(besidetheoutdoortemperaturedigit), indicatingthatthermosensorinlowbatterystatus.Thebatteriesshouldbereplaced. 11.PrecautionszUseapintopresstheresetbutton(B5)iftheUnitdoesnotworkproperly.zAllSettingModeswillautomaticallyexitin15secondswithoutanyadjustment.zTheclocklosesitstimeinformationwhenthebatteryisremoved.
zAvoidplacingtheclocknearinterferencesources/metalframessuchascomputerorTVsets.zDonotexposeittodirectsunlight,heavyheat,cold,highhumidityorwetareaszThe outdoor sensor must not be set up and installed under water. Set it up inawaydirectsunlightandRain zNevercleanthedeviceusingabrasiveorcorrosivematerialsorproducts.AbrasivecleaningagentsmayscratchplasticpartsandcorrodeelectroniccircuitsChanges or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment.

Navigation menu