CAEN RFID srl CAENRFID010 Low Power OEM UHF Compact RFID Reader User Manual easy2read protocol

CAEN RFID srl Low Power OEM UHF Compact RFID Reader easy2read protocol

Users Manual II

     CAEN UHF RFID READERS      COMMUNICATION PROTOCOL                                Technical Information Manual  Revision n. 12 14/01/2011
 CAEN UHF RFID Readers Communication Protocol – Technical Information Manual 2 Scope of Manual The goal of this manual is to provide the basic information to work with the CAEN UHF RFID READERS Communication Protocol.   Reference Document [RD1] Reader Protocol 1.0 – Working Draft Version of 25 August 2004 – Document revision 33 - EPCGlobal [RD2] EPC  Radio  Frequency Identity  Protocols  Class-1  Generation-2  UHF  RFID  Protocol  for  Communications  at 860MHz – 960MHz – Version 1.0.9 – EPCGlobal [RD3] ISO/IEC  FDIS  18000-6:2003(E)  –  Information  technology  automatic  identification  and  data  capture techniques – Radio frequency identification for item management air interface – Part 6: Parameters for air interface communication at 860-960 MHz    CAEN RFID srl Via Vetraia, 11 55049 Viareggio (LU) - ITALY Tel. +39.0584.388.398  Fax +39.0584.388.959 info@caenrfid.it  www.caenrfid.it    © CAEN RFID srl – 2010 Disclaimer No  part  of  this  manual  may  be  reproduced  in  any  form  or  by  any  means,  electronic,  mechanical,  recording,  or otherwise, without the prior written permission of CAEN RFID. The information contained herein has been carefully checked and is believed to be accurate; however, no responsibility is  assumed  for  inaccuracies.  CAEN  RFID  reserves  the  right  to  modify  its  products  specifications  without  giving  any notice; for up to date information please visit www.caenrfid.it.   Federal Communications Commission (FCC) Notice (Preliminary) 1 This device was tested and found to comply with the limits set forth in Part 15 of the FCC Rules. Operation is subject to the  following  conditions:  (1)  this  device  may  not  cause  harmful  interference,  and  (2)  this  device  must  accept  any interference received including interference that may cause undesired operation. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.   This device generates, uses, and can radiate radio frequency energy. If not installed and used in accordance with the instruction manual, the product may cause harmful interference to radio communications. Operation of this product in a residential area is likely to cause harmful interference, in which case, the user is required to correct the interference at their own expense. The authority to operate this product is conditioned by the requirements that no modifications be made to the equipment unless the changes or modifications are expressly approved by CAEN RFID.                                                         1 This declaration only applies to FCC readers A828US, A829US, A528, R1230CB, R1260I.
 CAEN UHF RFID Readers Communication Protocol - Technical Information Manual 3 Index Scope of Manual .......................................................................................................................... 2 Reference Document ................................................................................................................... 2 Index.......................................................................................................................................... 3 List of Tables .............................................................................................................................. 3 1 Introduction ....................................................................................................................... 4 General Information .................................................................................................................... 5 2 Protocol Specification ......................................................................................................... 6 Attribute types ............................................................................................................................. 8 Command codes ........................................................................................................................ 12 3 ASYNCHRONOUS NOTIFICATION:  PROTOCOL SPECIFICATION ........................................... 21 4 DEFAULT CONFIGURATION ............................................................................................... 23 5 EXAMPLES ........................................................................................................................ 25 Set Protocol Command .............................................................................................................. 26 Inventory Command .................................................................................................................. 27  List of Tables Tab. 2.1: Attribute types .................................................................................................................... 11 Tab. 2.2: Command codes .................................................................................................................. 20 Tab. 3.1: Attribute types: Notification AVP List. ................................................................................ 22 Tab. 4.1: A928EUEU and A948EUEU Configuration parameters default values ............................... 24 Tab. 4.2: A928EUEU and A948EUEU Default composition of sources .............................................. 24 Tab. 4.3: A828EU A828AEUEU, A829EUEU, A946EUEU and A949EUEU Configuration parameters default values ............................................................................................................................. 24 Tab. 4.4: A828EU A828AEUEU, A829EUEU, A946EUEU and A949EUEU Default composition of sources ....................................................................................................................................... 24
 CAEN UHF RFID Readers Communication Protocol – Technical Information Manual 4 1 Introduction
 CAEN UHF RFID Readers Communication Protocol - Technical Information Manual 5 General Information This document describes the message format of the communication protocol used by the host and the reader in order to issuing commands and reply with responses. The protocol is based on the Attribute Value Pair (AVP) schema and foresees a message header in order to identify the message scope.  The command set and the firmware architecture draw inspiration from the Reader Protocol 1.0 specification draft from EPCGlobal but, at now, this protocol is not fully compatible with the same last specifications. Message fields are described left to right, with the most significant byte on the left and the least on the right.
 CAEN UHF RFID Readers Communication Protocol – Technical Information Manual 6 2 Protocol Specification
 CAEN UHF RFID Readers Communication Protocol - Technical Information Manual 7 CAEN UHF RFID Reader protocol uses two logical communication channels: one for synchronous commands and one for  asynchronous  notifications.  Command  channel  is  mandatory  and,  at  now,  it  is  implemented  on  top  of  a  TCP/IP socket (port 1000) and on RS232 while notification channels are implemented only with sockets. All the messages (commands, responses and notifications) are composed by a header and a body. In all cases the body of the message is a list of attribute-value pairs. Responses always echo the Command AVP sent by the host.  All the packets for the control and notification channel share a common header format:                       1                   2                   3    0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 +-------------------------------+------------------------------+ |             FIXED             |          Message ID          | +-------------------------------+------------------------------+ |                           Vendor ID                          | +-------------------------------+------------------------------+ |            Length             |  +-------------------------------+   FIXED: Must be 0x8001 for commands and 0x0001 for responses. Message  ID:  Id  of  the  message.  It  is  a  sequence  number  used  to  map  requests  to  its  responses:  a  request  and  its corresponding response have the same message ID (the id is local to the channel). Vendor ID: Must be 21336: the IANA “SMI Network Management Private Enterprise Code” assigned to CAEN SpA. Length: Encodes the length of the message (in bytes) including the header.  The header is followed by a list of AVPs the number of which depends on the command. Each AVP have the following format:                       1                   2                   3    0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 +-------------------------------+------------------------------+ |           RESERVED            |           Length             | +-------------------------------+------------------------------+ |        Attribute Type         |       Attribute Value ………    | +-------------------------------+------------------------------+ |              ………[ until length is reached ]………               | +--------------------------------------------------------------+  RESERVED: The first 16 bits are reserved for future extensions. All reserved bits must be set to 0 on outgoing messages and ignored on incoming messages. Length: Encodes the length of the AVP packet including the length and the reserved fields. Attribute type: A 2 byte code identifying the attribute type. Attribute value: The actual attribute value according to the type. It follows immediately after the Attribute Type field and runs for the remaining bytes indicated in the Length (i.e. Length minus 6 bytes of header).
 CAEN UHF RFID Readers Communication Protocol – Technical Information Manual 8 Attribute types Code Description 0x01 CommandName: the command to be executed. All the commands are specified in the relevant table. Attribute value is 2 bytes long. 0x02 ResultCode: a code representing an indication on the result of the command. All the commands are specified in the relevant table. Attribute value is 2 bytes long. 0x0E EventType: the type of the notified event. Attribute value is 4 bytes long and  can assume the following values:  0x00 = Unknown Event 0x01 = Tag glimpsed 0x02 = Tag New 0x03 = Tag Observed 0x04 = Tag Lost 0x05 = Tag Purged 0x0F TagIDLen: the length of the tag ID. Attribute value is 2 bytes long. 0x10 TimeStamp: an indication of the time. Attribute is 8 bytes long and must be interpreted as follow: - the 4 least significant bytes are the seconds elapsed from the 1 January 1970. - the 4 most significant bytes are the micro-seconds. 0x11 TagID: the ID read from the tag. Attribute value has a maximum length of 12 bytes. For ISO18000 tags only the first 8 bytes are significant while for EPC tags all the 12 bytes are significant. 0x12 TagType: the tag’s type. Attribute value is 2 bytes long and  can assume the following values: 0x00 = ISO18KB 0x01 = EPCC1G1 0x02 = ISO18KA 0x03 = EPCC1G2 0x05 = EPC119 0x1E ChannelName: the name of the notification channel. Attribute value has a maximum length of 30 bytes. 0x1F ChannelAddress: the address of the notification channel. Attribute value has a maximum length of 30 bytes. 0x20 TriggerName: the name of the trigger. Attribute value has a maximum length of 30 bytes. 0x21 TriggerType: the type of the trigger. Attribute value has a maximum length of 30 bytes. 0x22 ReadPointName: a string representing the name of the read point. Attribute value has a maximum length of 5 bytes and can assume the following values: “Ant0”, “Ant1”, “Ant2”, “Ant3” 0x4D TagValue: data read from the tag memory (when applicable). Attribute value has a maximum length of 128 bytes. 0x4E TagAddress: the memory location address of the tag where read or write data (when applicable). Attribute value is 2 bytes long. 0x4F RESERVED. 0x50 Length: a value representing the length of a parameter. Attribute value is 2 bytes long.  0x51 BitRate: a value representing the RF BitRate. Attribute value is 2 bytes long and can assume the following values: 0x0 – Transmit : DSB ASK 10kbit,  Receive : FM0 10kbit 0x1 – Transmit : DSB ASK 10kbit,  Receive : FM0 40kbit 0x2 – Transmit : DSB ASK 40kbit,  Receive : FM0 40kbit 0x3 – Transmit : DSB ASK 40kbit,  Receive : FM0 160kbit   0x4 – Transmit : DSB ASK 160kbit, Receive : FM0 400kbit   0x5 – Transmit : DSB ASK 40kbit,   Receive : Miller M=2 160kbit   0x6 – Transmit : PR ASK 40kbit,     Receive : Miller M=4  250kbit   0x7 – Transmit : PR ASK 40kbit,     Receive : Miller M=4  300kbit   0x8 – Transmit : PR ASK 40kbit,     Receive : Miller M=2  250kbit Note: not all the value are supported by all the readers. For the list of mode supported by each reader please refer to the reader’s user manual.   0x52 PowerGet: a value representing the RF power. Attribute value is 4 bytes long. (used for read the current setting)
 CAEN UHF RFID Readers Communication Protocol - Technical Information Manual 9 Code Description 0x53 RESERVED. 0x54 Protocol: a value representing the air protocol. Attribute value is 4 bytes long and can assume the following values:  0x00 = ISO18000-6B 0x01 = EPCC1G1 0x02 = ISO18000-6A 0x03 = EPCC1G2 0x56 ReadPointStatus: a value representing the antenna’s status. Attribute value is 4 bytes long and can assume the following values: 0x00 = Bad: antenna is not connected or broken. 0x01 = Poor: antenna has a low quality connection. 0x02 = Good: antenna is well connected. 0x57 Boolean: a value representing a boolean data.  Attribute value is 2 bytes long and can assume the following values: 0x00 = FALSE. Not 0x00 = TRUE. 0x58 IPAddress: a string representing an IP address formatted with the standard IP dotted decimal format. Attribute value has a maximum length of 30 bytes. 0x59 IPNetMask: a string representing an IP netmask formatted with the standard IP dotted decimal format. Attribute value has a maximum length of 30 bytes. 0x5A IPGateway: a string representing an IP address formatted with the standard IP dotted decimal format. Attribute value has a maximum length of 30 bytes. 0x5B DESBEnable: used to enable/disable the Data Exchange Status Bit handling for ISO18000-6b and EPC 1.19 anti-collision algorithm. Attribute value is 2 bytes long and can assume the following values: 0x00 = Disable the DESB handling. Not 0x00 = Enable the DESB handling. 0x5C FWRelease: a string representing the device’s firmware revision. Attribute value has a maximum length of 200 bytes. 0x5D DESBStatus: used to check the Data Exchange Status Bit handling for ISO18000-6b and EPC 1.19 anti-collision algorithm. Attribute value is 2 bytes long and can assume the following values: 0x00 = DESB handling is not enabled. Not 0x00 = DESB handling is enabled. 0x5E EPCPWD: a value representing an EPC tag password. Attribute value is 2 bytes long. 0x5F RFOnOff: used to start the generation of a continuous wave for test purposes. Attribute value is 2 bytes long and can assume the following vaules: 0x00 = Stop the wave generation. Not 0x00 = Start the wave generation. 0x60 BaudRate: a value representing the baudrate setting of serial port. Attribute value is 4 bytes long. 0x61 DataBits: a value representing the databits setting of serial port. Attribute value is 4 bytes long. 0x62 StopBits: a value representing the stopbits setting of serial port. Attribute value is 4 bytes long. 0x63 Parity: a value representing the parity setting of serial port. Attribute value is 4 bytes long and can assume the following values: 0x00 = No parity 0x01 = Odd parity 0x02 = Even parity 0x64 FlowCtrl: a value representing the flow control setting of serial port. Attribute value is 4 bytes long and can assume the following values: 0x00 = No flow control 0x01 = Hardware flow control 0x02 = Software flow control (not yet implemented) 0x65 DateTime: a value representing a date and time. Attribute value has a maximum length of 30 bytes. The data format is: YYYY–MM–DD HH:MM:SS
 CAEN UHF RFID Readers Communication Protocol – Technical Information Manual 10 Code Description 0x66 SelUnselOp: a value representing the tag selection operation defined by the ISO18000-6B protocol. Attribute value is 2 bytes long and can assume the following values: 0x00 = select equal 0x01 = select not equal 0x02 = select greater than 0x03 = select lower than 0x04 = unselect equal 0x05 = unselect not equal 0x06 = unselect greater than 0x07 = unselect lower than 0x67 Bitmask: a value representing the bitmask parameter of tag selection operations defined by the ISO18000-6B protocol. Attribute value is 2 bytes long (only 8 least significant bits are used). 0x68 REESERVED.  0x69 IORegister: a value representing the status of the I/O lines of the reader. Where input lines are separated from output ones, input lines are mapped on the less significant bits while outputs are mapped on the most significant. Attribute value is 4 bytes long (effective used bits depend on the reader model). 0x6A ConfigParameter: a value representing a configuration parameter. Attribute value is 4 bytes long and can assume the following values: 0x00 = ReadCycle configuration 0x01 = Observed Threshold configuation 0x02 = Lost Threshold configuration 0x03 = Starting Q value (Valid values : 0  15 ). EPC C1GEN2 Protocol only. 0x04 = Session (Valid values : 0  3 ). EPC C1GEN2 protocol only. 0x05 = Target (Valid values : 0  1 ).  EPC C1GEN2 protocol only. 0x06 = Selected  (Valid values : 0  1 ).  EPC C1GEN2 protocol only. 0x07 = Data Exchange Status B (Valid values : 0  1 ).  ISO 18000-6B protocol only. 0x08 = Antenna dwell time during inventory (msec). A528 only. 0x09 = Inventory type (Valid values : 0  3 ).  A528 only. 0x6B ConfigValue: a value for the configuration parameter. Attribute value is 4 bytes long. 0x6C NoOfTriggers: a value representing the number of triggers. Attribute value is 2 bytes long. 0x6D NoOfChannels: a value representing the number of channels. Attribute value is 2 bytes long. 0x6E EventMode: a value representing the event handling mode. Attribute value is 2 bytes long and can assume the following values: 0x00 = ReadCycle mode 0x01 = Time Mode 0x02 = No Event Mode 0x6F UpgradeType: a value representing the type of upgrade to perform. Attribute value is 2 bytes long and can assume the following values: 0x01 = TFTP firmware upgrade. 0x70 UpgradeArgument: a value representing the argument for the requested upgrade. Attribute value has a maximum length of 255 bytes. For TFTP upgrade (code 0x01) the string has the form: ‘<tftpserverip>:<filename>’. 0x71 MemoryBank: a value representing the memory bank of a EPC Class 1 Generation 2 tag. Attribute value is 2 bytes long and can assume the following values: 0x00 = Reserved Memory Bank 0x01 = EPC Memory Bank 0x02 = TID Memory Bank 0x03 = User Memory Bank 0x72 Payload: a value representing the payload parameter for the EPC Class 1 Gen 2 lock command (see the EPC Gen2 specification for details). Attribute value is 4 bytes long. 0x73 G2Password: a value representing the Acess / Kill password parameter for the EPC Class 1 Gen 2 commands (see the EPC Gen2 specification for details). Attribute value is 4 bytes long. 0x74 G2NSI: a value representing the numbering system identifier for the EPC Class 1 Gen 2 tags’ id (see the EPC Gen2 specification for details). Attribute value is 2 bytes long. 0x75 QParameter: a value representing the initial value for the Q parameter involved in the EPC Class 1 Gen 2 anticollision algorithm (see the EPC Gen2 specification for details). Attribute value is 2 bytes long. 0x76 ReaderInfo: a string indicating the model and the serial number of the reader.
 CAEN UHF RFID Readers Communication Protocol - Technical Information Manual 11 Code Description 0x77 RFRegulation: a value representing the RF regulation to use. Attribute value is 2 bytes long and can assume the following values: 0x00 = ETSI EN 302 208 0x01 = ETSI EN 300 220 0x02 = FCC 0x03  = Malaysia 0x04  = Japan       0x05  = Korea       0x06  = Australia   0x07  = China       Note: not all the value are supported by all the readers. For the list of RF regulation supported by each reader please refer to the reader’s user manual.   0x78 RFChannel: a value representing the RF channel to use. Attribute value is 2 bytes long and can assume values in the range 0 … 9. Channels are referred to the ETSI EN 302 208 regulation.  0x7A RSSI: a value representing the backscattered RF field strenght. Attribute value is 2 bytes long. 0x96 PowerSet: a value representing the RF power emitted during the communication with tags. Attribute value is 4 bytes long. (used to set a new current value). 0xFB SourceName: a string representing the name of the data source. Attribute value has a maximum length of 30 bytes and can assume the following values: “Source_0”, “Source_1”, “Source_2”, “Source_3” Tab. 2.1: Attribute types
 CAEN UHF RFID Readers Communication Protocol – Technical Information Manual 12 Command codes  Code Description Comp. 0x12 RawReadIDs: permits to get all the tag’s Ids that are under the RF field of the selected source (Deprecated).  Parameters: SourceNameIn: [in] the name of the source to use. SourceNameOut: [out] the name of the source used. ReadPointName: [out] the name of the readpoint. TimeStamp: [out] the time at which the tags are detected. TagIDLen: [out] the ID length of the tags detected. ListOfIDs: [out] the list of Ids detected from the source. ResultCode: [out] the result code.  Note: out parameters are repeated for each readpoint in the source. A928EU A948EU A828EU A828AEU A829EU A949EU  0x13 NewRawReadIDs: permits to get all the tag’s Ids that are under the RF field of the selected source.  Parameters: SourceNameIn: [in] the name of the source to use (optional). Length: [in] Filter Mask Lenght (optional). TagID: [in] the Filter Mask Value (optional). TagAddress: [in] Filter Mask Start Address (optional) Bitmask: [in] Inventory Flags. When set to 1 for each tag detected the RSSI value is returned. Default value 0. (optional, A528 only).  For each tag detected the parameters returned by the command are:   SourceNameOut: [out] the name of the source used  ReadPointName: [out] the name of the readpoint. TimeStamp: [out] the time at which the tags are detected. TagType: *out+ the tag’s type. TagIDLen: [out] the ID length of the tags detected. TagID: *out+ the tag’s id. RSSI: [out] the tag’s backscattered field strength (optional, A528 only) ResultCode: [out] the result code.  Note: out parameters are repeated for each readpoint in the source. A928EU A948EU A828EU A828AEU A829EU A949EU A528 R1230CB R1260I 0x3F AddReadTrigger: permits to add a trigger to a source.  Parameters: SourceName: [in] the name of the source. TriggerName: [in] the name of the trigger. ResultCode: [out] the result code. A928EU A948EU 0x40 AddNotifyTrigger: permits to add a trigger to a notification channel.  Parameters: ChannelName: [in] the name of the channel. TriggerName: [in] the name of the trigger. ResultCode: [out] the result code. A928EU A948EU 0x41 RemoveReadTrigger: permits to remove a trigger from a source.  Parameters: SourceName: [in] the name of the source. TriggerName: [in] the name of the trigger. ResultCode: [out] the result code. A928EU A948EU 0x42 RemoveNotifyTrigger: permits to remove a trigger from a notification channel. Parameters: ChannelName: [in] the name of the channel. TriggerName: [in] the name of the trigger. ResultCode: [out] the result code. A928EU A948EU
 CAEN UHF RFID Readers Communication Protocol - Technical Information Manual 13 Code Description Comp. 0x49 AllocateTrigger: permits to create a new trigger. Parameters: TriggerName: [in] the name of the trigger. TriggerType: [in] the type of the trigger. ResultCode: [out] the result code. A928EU A948EU 0x4A DeallocateTrigger: permits to destroy an existing trigger. Parameters: TriggerName: [in] the name of the trigger. ResultCode: [out] the result code. A928EU A948EU 0x53 AllocateChannel: permits to create a notification channel. Parameters: ChannelName: [in] the name of the channel. ChannelAddress: [in] the address of the channel. ResultCode: [out] the result code. A928EU A948EU 0x54 DeallocateChannel: permits to destroy a notification channel. Parameters: ChannelName: [in] the name of the channel. ResultCode: [out] the result code. A928EU A948EU 0x5D AddSourceToChannel: permits to add a source to a notification channel. Parameters: SourceName: [in] the name of the source. ChannelName: [in] the name of the channel. ResultCode: [out] the result code. A928EU A948EU 0x5E RemoveSourceFromChannel: permits to remove a source from a notification channel. Parameters: SourceName: [in] the name of the source. ChannelName: [in] the name of the channel. ResultCode: [out] the result code. A928EU A948EU 0x5F AddReadPointToSource: permits to add a readpoint to a source. Parameters: SourceName: [in] the name of the source. ReadPointName: [in] the name of the readpoint. ResultCode: [out] the result code. A928EU A948EU A528 R1230CB R1260I 0x60 RemoveReadPointFromSource: permits to remove a readpoint from a source. Parameters: SourceName: [in] the name of the source. ReadPointName: [in] the name of the readpoint. ResultCode: [out] the result code. A928EU A948EU A528 R1230CB R1260I 0x64 SetPower: permits to set the RF power level. Parameters: PowerSet: [in] the power level to set. ResultCode: [out] the result code.  A928EU A948EU A949EU A528 A828AEU R1230CB R1260I 0x6E ReadTagData: permits to read data from the tag memory. Parameters: SourceName: [in] the name of the source to use. TagIDLen: [in] the ID length of the tag. TagID: [in] the ID of the tag. TagAddress: [in] the address from which read the data. Length: [in] the number of bytes to read. TagValue: [out] the data read from the tag memory. ResultCode: [out] the result code. A928EU A948EU A828EU A828AEU A829EU A949EU R1230CB R1260I
 CAEN UHF RFID Readers Communication Protocol – Technical Information Manual 14 Code Description Comp. 0x6F WriteTagData: permits to write data to the tag memory. Parameters: SourceName: [in] the name of the source to use. TagIDLen: [in] the ID length of the tag. TagID: [in] the ID of the tag. TagAddress: [in] the address where to write the data. Length: [in] the number of bytes to write. TagValue: [in] the data to write to the tag memory. ResultCode: [out] the result code. A928EU A948EU A828EU A828AEU A829EU A949EU R1230CB R1260I  0x70 LockTag: permits to lock data into the tag memory. Parameters: SourceName: [in] the name of the source to use. TagIDLen: [in] the ID length of the tag. TagID: [in] the ID of the tag. TagAddress: [in] the address where to write the data. ResultCode: [out] the result code. A928EU A948EU A828EU A828AEU A829EU A949EU R1230CB R1260I  0x71 RESERVED  0x72 SetBitRate: permits to set the BitRate to use. Parameters: BitRate: [in] the BitRate to set. ResultCode: [out] the result code. A928EU A948EU A828EU A828AEU A829EU A949EU A528 R1230CB R1260I 0x73 GetPower: permits to get the current RF power level. Parameters: PowerGet: [out] the current power level. ResultCode: [out] the result code. A928EU A948EU A949EU A528 R1230CB R1260I 0x74 SetProtocol: permits to set the protocol to use. Parameters: Protocol: [in] the protocol to use. ResultCode: [out] the result code. A928EU A948EU A828EU A828AEU A829EU A949EU A528 R1230CB R1260I 0x75 RESERVED  0x76 CheckReadPointStatus: permits to check the quality of the antenna connection. Parameters: ReadPointName: [in] the name of the readpoint. ReadPointStatus: [out] the quality of the connection. ResultCode: [out] the result code. A928EU A948EU A949EU 0x77 CheckSourceInChannel: permits to verify if a source is assigned to a notify channel. Parameters: SourceName: [in] the name of the source. ChannelName: [in] the name of the channel. Value: [out] a Boolean value meaning the belonging to the source. ResultCode: [out] the result code. A928EU A948EU
 CAEN UHF RFID Readers Communication Protocol - Technical Information Manual 15 Code Description Comp. 0x78 CheckReadPointInSource: permits to verify if a readpoint belongs to a givens source. Parameters: ReadPointName: [in] the name of the readpoint. SourceName: [in] the name of the source. Value: [out] a Boolean value meaning the belonging to the source. ResultCode: [out] the result code. A928EU A948EU A949EU A528 R1230CB R1260I 0x79 GetProtocol: permits to get the protocol in use. Parameters: Protocol: [out] the protocol in use. ResultCode: [out] the result code. A928EU A948EU A828EU A828AEU A829EU A949EU A528 R1230CB R1260I 0x7A SetNetwork: permits to set up the network configuration. Parameters: IPAddress: [in] the IP address to set. IPNetMask: [in] the IP netmask to set. IPGateway: [in] the IP gateway to set. ResultCode: [out] the result code. A928EU A948EU 0x7B SetDESB: permits to enable or disable the “Data Exchange Status Bit” handling during the anti-collision algorithm when ISO 18000-6b air protocol is in use. Parameters: DESBEnable: [in] enable/disable value. ResultCode: [out] the result code. A928EU A948EU A828EU A828AEU A829EU A949EU  0x7C GetFirmwareRelease: permits to get the firmware revision. Parameters: FWRelease: [in] the firmware release. ResultCode: [out] the result code. A928EU A948EU A828EU A828AEU A829EU A949EU A528 R1230CB R1260I 0x7D GetDESB: permits to get the current setting of the “Data Exchange Status Bit” handling. Parameters: DESBStatus: [in] enabled/disabled value. ResultCode: [out] the result code. A928EU A948EU A828EU A828AEU A829EU A949EU  0x7E ProgramID: permits to program the ID in the EPC Class 1 Gen 1 tags. Parameters: SourceName: [in] the name of the source. TagIDLen: [in] the ID length of the tag. TagID: [in] the ID of the tag. EPCPWD: [in] the EPC password to set. Lock: [in] a Boolean value; TRUE = lock the ID. FALSE = do not lock. ResultCode: [out] the result code. A928EU A948EU  0x7F KillTag: permits to kill a EPC Class 1 Gen 1 tag. Parameters: SourceName: [in] the name of the source. TagIDLen: [in] the ID length of the tag. TagID: [in] the ID of the tag. EPCPWD: [in] the EPC password. ResultCode: [out] the result code. A928EU A948EU
 CAEN UHF RFID Readers Communication Protocol – Technical Information Manual 16 Code Description Comp. 0x80 RFOnOff: permits to start/stop the generation of a continuous wave. Used only for test and measurements purposes. Parameters: RFOnOff: [in] = 0  stop; != 0  start  ResultCode: [out] the result code. A928EU A948EU A828EU A828AEU A829EU A949EU A528 R1230CB R1260I 0x81 GetBitRate: permits to get the BitRate in use. Parameters: BitRate: [out] the BitRate in. ResultCode: [out] the result code. A928EU A948EU A828EU A828AEU A829EU A949EU A528 R1230CB R1260I 0x82 BlockWriteTag: permits to write data to the tag memory. This function uses the ISO18000-6b Write4Byte command to speed up the writing of large amount of data at one time.  Parameters: SourceName: [in] the name of the source to use. TagIDLen: [in] the ID length of the tag. TagID: [in] the ID of the tag. TagAddress: [in] the address where to write the data. Length: [in] the number of bytes to write. TagValue: [in] the data to write to the tag memory. ResultCode: [out] the result code. A928EU A948EU A828EU A828AEU A829EU A949EU  0x83 SetRS232: permits to modify the settings of the serial port.  Parameters: Baudrate: [in] the baud rate value. Databits: [in] the data bits setting. Stopbits: [in] the stop bits setting. Parity: [in] the parity setting. Flowctrl: [in] the flow control setting. ResultCode: [out] the result code. A928EU A948EU A828EU A828AEU A829EU A949EU A528 R1230CB R1260I 0x84 SetDateTime: permits to modify date and time.  Parameters: Datetime: [in] the date and time to set up. ResultCode: [out] the result code. A928EU A948EU A828EU A828AEU A829EU A949EU  0x85 GroupSelectUnselect: permits to execute the tag selection commands defined by the ISO18000-6B protocol.  Parameters: SourceName: [in, optional] the name of the source to use. Operation: [in] the tag selection operation. Bytemask: [in] the byte mask as defined by the protocol.  TagAddress: [in] the address where to compare the data. TagValue: [in] the data to compare with the tag memory. TagID: [out] the ID of the tag. ResultCode: [out] the result code. A928EU A948EU A828EU A828AEU A829EU A949EU
 CAEN UHF RFID Readers Communication Protocol - Technical Information Manual 17 Code Description Comp. 0x86 GetIO: permits to read the current status of the I/O lines. Parameters: IORegister: [out] the status of the I/O lines. ResultCode: [out] the result code. A928EU A948EU A828EU A828AEU A829EU A949EU A528 R1230CB R1260I 0x87 SetIO: permits to set the level of the output lines. Parameters: IORegister: [in] the value to set to the output lines. ResultCode: [out] the result code. A928EU A948EU A828EU A828AEU A829EU A949EU A528 R1230CB R1260I 0x88 SetIODirection: permits to define the direction of the I/O lines.  (0 = input; 1 = output) Parameters: IORegister: [in] the direction to set to the I/O lines. ResultCode: [out] the result code. A828EU A828AEU A829EU A949EU A528 R1230CB R1260I 0x89 GetIODirection: permits to read the current status of the I/O lines. (0 = input; 1 = output) Parameters: IORegister: [out] the direction of the I/O lines. ResultCode: [out] the result code. A828EU A828AEU A829EU A949EU A528 R1230CB R1260I 0x8A SetSourceConfig: permits to set a configure parameter for a logical source. Parameters: SourceName: [in] the name of the source to configure. ConfigParameter: [in] the code of the parameter. ConfigValue: [in] the value for the parameter. ResultCode: [out] the result code. A928EU A948EU A528 R1230CB R1260I 0x8B GetSourceConfig: permits to read a configure parameter for a logical source. Parameters: SourceName: [in] the name of the source to configure. ConfigParameter: [in] the code of the parameter. ConfigValue: [out] the value for the parameter. ResultCode: [out] the result code. A928EU A948EU A528 R1230CB R1260I 0x8C GetTriggers: permits to read the names of the allocated triggers. Parameters: NoOfTriggers: [out] the number of allocated triggers. ListOfTriggerNames: [in] a list containing the names of the allocated triggers. ResultCode: [out] the result code. A928EU A948EU 0x8D GetChannels: permits to read the names of the allocated notification channels. Parameters: NoOfChannels: [out] the number of allocated channels. ListOfChannelNames: [in] a list containing the names of the allocated channels. ResultCode: [out] the result code. A928EU A948EU
 CAEN UHF RFID Readers Communication Protocol – Technical Information Manual 18 Code Description Comp. 0x8E CheckSourceInTrigger: permits to verify if the specified logical source is associated to the specified trigger.  Parameters: SourceName: [in] the name of the source. TriggerName: [in] the name of the trigger. Boolean: [out] 0 if they are associated, ≠0 if not. ResultCode: [out] the result code. A928EU A948EU 0x8F CheckTriggerInChannel: permits to verify if the specified trigger is associated to the specified channel.  Parameters: ChannelName: [in] the name of the source. TriggerName: [in] the name of the trigger. Boolean: [out] 0 if they are associated, ≠0 if not. ResultCode: [out] the result code. A928EU A948EU 0x90 CheckChannelInTrigger: permits to verify if the specified channel is associated to the specified trigger.  Parameters: ChannelName: [in] the name of the source. TriggerName: [in] the name of the trigger. Boolean: [out] 0 if they are associated, ≠0 if not. ResultCode: [out] the result code. A928EU A948EU 0x91 SetEventMode: permits to set the event generation mode for the reader notification channels. Parameters: EventMode: [in] the event mode. ResultCode: [out] the result code. A928EU A948EU 0x92 GetEventMode: permits to read the event generation mode for the reader notification channels. Parameters: EventMode: [out] the event mode. ResultCode: [out] the result code. A928EU A948EU 0x93 FirmwareUpgrade: permits to upgrade the reader firmware. Parameters: UpgradeType: [in] the type of the upgrade. UpgradeArg: [in] the argument needed by the upgrade procedure. ResultCode: [out] the result code. A928EU A948EU 0x94 E119ProgramID: permits to write the EPC into a EPC1.19 tag. Parameters: SourceName: [in] the name of the source to use. TagID: [in] the old EPC of the tag. TagValue: [in] the EPC to write into the tag memory. ResultCode: [out] the result code. A928EU A948EU A828EU A828AEU A829EU A949EU  0x95 G2ProgramID: permits to write the EPC in a Class 1 Gen 2 tag. Parameters: SourceName: [in] the name of the source to use. TagIDLen: [in] the ID length of the tag (must be an even number). TagID: [in] the EPC to write into the tag memory. G2NSI: [in] the EPC numbering system. G2Password: [in] the EPC Access password (optional). ResultCode: [out] the result code. A928EU A948EU A828EU A828AEU A829EU A949EU A528 R1230CB R1260I
 CAEN UHF RFID Readers Communication Protocol - Technical Information Manual 19 Code Description Comp. 0x96 G2Read: permits to read data from anyone of the Gen2 tag memory banks. Parameters: SourceName: [in, optional] the name of the source to use. TagIDLen: [in] the ID length of the tag. TagID: [in] the ID of the tag. MemoryBank: [in] the memory bank.  TagAddress: [in] the address where to read the data. Length: [in] the number of bytes to read (must be an even number). TagValue: [out] the data read from the tag memory. G2Password: [in] the EPC Access password (optional). ResultCode: [out] the result code. A928EU A948EU A828EU A828AEU A829EU A949EU A528 R1230CB R1260I 0x97 G2Write: permits to write data into anyone of the Gen2 tag memory banks. Parameters: SourceName: [in, optional] the name of the source to use. TagIDLen: [in] the ID length of the tag. TagID: [in] the ID of the tag. MemoryBank: [in] the memory bank.  TagAddress: [in] the address where to write the data. Length: [in] the number of bytes to write (must be an even number). TagValue: [in] the data to write to the tag memory. G2Password: [in] the EPC Access password (optional). ResultCode: [out] the result code. A928EU A948EU A828EU A828AEU A829EU A949EU A528 R1230CB R1260I 0x98 G2Lock: permits to execute the tag lock command defined by the EPC Class 1 Gen 2 protocol. Parameters: SourceName: [in, optional] the name of the source to use. TagIDLen: [in] the ID length of the tag. TagID: [in] the ID of the tag. G2Payload: [in] the lock payload.  G2Password: [in] the EPC Access password (optional). ResultCode: [out] the result code. A928EU A948EU A828EU A828AEU A829EU A949EU A528 R1230CB R1260I 0x99 G2Kill: permits to execute the tag kill command defined by the EPC Class 1 Gen 2 protocol. Parameters: SourceName: [in, optional] the name of the source to use. TagIDLen: [in] the ID length of the tag. TagID: [in] the ID of the tag. G2Password: [in] the kill password.  ResultCode: [out] the result code. A928EU A948EU A828EU A828AEU A829EU A949EU A528 R1230CB R1260I 0x9A G2Query: permits to execute the tag query command defined by the EPC Class 1 Gen 2 protocol. If a tag is in the field result code is ERROR_SUCCESS (0x00) else result code is ERROR_TAGNOTPRESENT (0xCA). Parameters: SourceName: [in] the name of the source to use. ResultCode: [out] the result code. A928EU A948EU A828EU A828AEU A829EU A949EU A528 R1230CB R1260I  0x9B G2SetQ: permits to change the initial value of the Q parameter used in the Gen2 anticollision algorithm. Parameters: QParameter: [in] the value of the Q parameter. ResultCode: [out] the result code. A928EU A948EU A828EU A828AEU A829EU A949EU A528 R1230CB R1260I
 CAEN UHF RFID Readers Communication Protocol – Technical Information Manual 20 Code Description Comp. 0x9C G2GetQ: permits to read the initial value of the Q parameter used in the Gen2 anticollision algorithm. Parameters: QParameter: [out] the value of the Q parameter. ResultCode: [out] the result code. A928EU A948EU A828EU A828AEU A829EU A949EU A528 R1230CB R1260I 0x9D G2QueryAck: permits to execute the tag query and ack command defined by the EPC Class 1 Gen 2 protocol. If a tag is in the field result code is ERROR_SUCCESS (0x00) and the command returns the EPC code stored in the tag  else the result code is ERROR_TAGNOTPRESENT (0xCA). Parameters: SourceName: [in] the name of the source to use. TagID: [out] the ID of the tag. ResultCode: [out] the result code. A928EU A948EU A828EU A828AEU A829EU A949EU A528 R1230CB R1260I  0x9E GetReaderInfo: permits to read some information about the reader itself. Parameters: ReaderInfo: [out] a string with information about the reader. ResultCode: [out] the result code. A928EU A948EU A828EU A828AEU A829EU A949EU A528 R1230CB R1260I 0x9F SetLBTMode: permits to enable or disable the Listen Before Talk capability on ETSI EN 302 208 compatible readers. Parameters: Boolean: [in] 0 to disable LBT and ≠0 to enable LBT. ResultCode: [out] the result code. A948EU A949EU A528 R1230CB R1260I 0xA0 GetLBTMode: permits to read the current setting for the Listen Before Talk capability on ETSI EN 302 208 compatible readers. Parameters: Boolean: [out] 0 if LBT is disabled, ≠0 if LBT is enabled. ResultCode: [out] the result code. A948EU A949EU A528 R1230CB R1260I 0xA1 SetRFRegulation: permits to change the RF regulation used by the reader. Parameters: RFRegulation: [in] the desired RF regulation. ResultCode: [out] the result code. A948EU A949EU A528 R1230CB R1260I 0xA2 GetRFRegulation: permits to read the RF regulation used by the reader. Parameters: RFRegulation: [out] the desired RF regulation. ResultCode: [out] the result code. A948EU A949EU A528 R1230CB R1260I 0xA3 SetRFChannel: permits to set the RF channel where the reader emits the RF field. Parameters: RFChannel: [in] the RF channel. ResultCode: [out] the result code. A948EU A949EU A528 R1230CB R1260I 0xA4 GetRFChannel: permits to read the RF channel currently in use. Parameters: RFChannel: [out] the RF channel. ResultCode: [out] the result code.  A948EU A949EU A528 R1230CB R1260I 0xFFFF RESERVED  Tab. 2.2: Command codes
 CAEN UHF RFID Readers Communication Protocol - Technical Information Manual 21 3 ASYNCHRONOUS NOTIFICATION:  PROTOCOL SPECIFICATION
 CAEN UHF RFID Readers Communication Protocol – Technical Information Manual 22 The notification channels are implemented only with sockets. All the messages notifications are composed by a header and a body. In all cases the body of the message is a list of attribute-value pairs. The first AVP of the body is fixed and called NotifyMessage.  All the packets for notification channel share the same header format of other packet as described at § 3.  The first AVP (NotifyMessage) is followed by a list of AVPs, the number of which depends on how many tags should be notified. Each AVP has the same format of the AVP described in § 3.  The NotifyMessage has the following fixed format:                       1                   2                   3    0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 +-------------------------------+------------------------------+ |           RESERVED            |           8                  | +-------------------------------+------------------------------+ |         CommandName    |        ReportBuffer       | +-------------------------------+------------------------------+  After the NotifyMessage AVP we can receive:  a) a list of AVPs (as described in table 3) followed by an AVP with ‘Attribute Type’  ResultCode  b) a single AVP called KillMessage with the following fixed format:                       1                   2                   3    0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 +-------------------------------+------------------------------+ |           RESERVED            |           8                  | +-------------------------------+------------------------------+ |         KillCommand    |        KillCommand       | +-------------------------------+------------------------------+   Description TimeStamp: the timestamp of the notification TagIDLen: the ID length of the tag. TagID: the ID of the tag. SourceName: the name of the source to use. EventType: the type of the notified event Tab. 3.1: Attribute types: Notification AVP List.
 CAEN UHF RFID Readers Communication Protocol - Technical Information Manual 23 4 DEFAULT CONFIGURATION
 CAEN UHF RFID Readers Communication Protocol – Technical Information Manual 24 CAEN A928EUEU and A948EUEU UHF RFID Reader protocol has various configuration parameters; in the following table are summarized the default values.  Parameter Default value IP Address 192.168.0.125 IP Netmask 255.255.255.0 IP Gateway 192.168.0.1 Sources “Source_0”, “Source_1”, “Source_2”, “Source_3”  Readpoints “Ant0”, “Ant1”, “Ant2”, “Ant3” Baud Rate 115200 Data Bits 8 Stop Bits 1 Parity None Flow Control None Tab. 4.1: A928EUEU and A948EUEU Configuration parameters default values The default composition of sources for A928EUEU and A948EUEU reader is the following:  Source Readpoints Source_0 Ant0 Source_1 Ant1 Source_2 Ant2 Source_3 Ant3 Tab. 4.2: A928EUEU and A948EUEU Default composition of sources CAEN A828EU A828AEUEU, A829EUEU, A946EUEU and A949EUEU UHF RFID Reader protocol has various configuration parameters; in the following table are summarized the default values.  Parameter Default value Sources “Source_0”  Readpoints “Ant0” Baud Rate 115200 Data Bits 8 Stop Bits 1 Parity None Flow Control None Tab. 4.3: A828EU A828AEUEU, A829EUEU, A946EUEU and A949EUEU Configuration parameters default values The default composition of sources for the A828EU A828AEUEU, A829EUEU, A946EUEU and A949EUEU reader is the following:  Source Readpoints Source_0 Ant0 Tab. 4.4: A828EU A828AEUEU, A829EUEU, A946EUEU and A949EUEU Default composition of sources
5 EXAMPLES
 CAEN UHF RFID Readers Communication Protocol – Technical Information Manual 26 Set Protocol Command  Action: Set Reader Protocol to EPC C1G2 Result: Reader select EPC C1G2 protocol. Command sent: 0x8001      (Fixed) 0x0000      (Message ID) 0x00005358       (Vendor ID = CAEN SpA) 0x001C      (Message Length)  0x0000      (Reserved) 0x0008      (AVP Length) 0x0001      (AVP Type = CommandName) 0x0074      (AVP Value = SetProtocol)  0x0000      (Reserved) 0x000A      (AVP Length) 0x0054      (AVP Type = Protocol) 0x00000003      (AVP Value = EPC C1G2)  Response received: 0x0001      (Fixed) 0x0000      (Message ID) 0x00005358      (Vendor ID = CAEN SpA) 0x001A      (Overall Message Length)  0x0000      (Reserved) 0x0008      (AVP Length) 0x0001      (AVP Type = CommandName) 0x0074      (AVP Value = NewRawReadIDs)  0x0000      (Reserved) 0x0008      (AVP Length) 0x0002      (AVP Type = ResultCode) 0x0000      (AVP Value = Success)
 CAEN UHF RFID Readers Communication Protocol - Technical Information Manual 27 Inventory Command  Action: Execute an inventory cycle on the logical source Source0 Result: Two EPCC1G2 tags are returned as being inventory by the reader on Ant0.     Tag1 Id = 010203040506070809101112131415161718191920 (160 bit)     Tag2  Id =  300833B2DDD9014035050000 (96 bit) Command sent: 0x8001      (Fixed) 0x0000      (Message ID) 0x00005358       (Vendor ID = CAEN SpA) 0x0021      (Message Length)  0x0000      (Reserved) 0x0008      (AVP Length) 0x0001      (AVP Type = CommandName) 0x0013      (AVP Value = NewRawReadIDs)  0x0000      (Reserved) 0x000F      (AVP Length) 0x00FB      (AVP Type = SourceName) 0x536F757263655F3000    (AVP Value = “Source_0”)    Response received: 0x0001      (Fixed) 0x0000      (Message ID) 0x00005358      (Vendor ID = CAEN SpA) 0x00B6      (Overall Message Length)  0x0000      (Reserved) 0x0008      (AVP Length) 0x0001      (AVP Type = CommandName) 0x0013      (AVP Value = NewRawReadIDs)  0x0000      (Reserved) 0x000F      (AVP Length) 0x00FB      (AVP Type = SourceName) 0x536F757263655F3000  (AVP Value = “Source_0”)  0x0000      (Reserved) 0x000B      (AVP Length) 0x0022      (AVP Type = ReadPointName) 416E743000      (AVP Value = “Ant0”)  0x0000      (Reserved) 0x000E      (AVP Length) 0x0010      (AVP Type = TimeStamp) 0x00000578          (AVP Value = Thu Jan  1 01:23:20 1970) 0x00000000      (AVP Value)  0x0000      (Reserved) 0x0008      (AVP Length) 0x0012              (AVP Type = TagType) 0x0003              (AVP Value = EPCC1G2)  0x0000      (Reserved) 0x0008      (AVP Length) 0x000F      (AVP Type = TagIDLen) 0x0014      (AVP Value = 160 bit)  0x0000      (Reserved) 0x001A      (AVP Length) 0x0011      (AVP Type = TagID) 0x010203040506070809101112131415161718191920      0x0000      (Reserved) 0x000F      (AVP Length) 0x00FB      (AVP Type = SourceName)
 CAEN UHF RFID Readers Communication Protocol – Technical Information Manual 28 0x536F757263655F3000  (AVP Value)  0x0000      (Reserved) 0x000B      (AVP Length) 0x0022      (AVP Type = ReadPointName) 0x416E743000     (AVP Value = “Ant0”)  0x0000      (Reserved) 0x000E      (AVP Length) 0x0010      (AVP Type = TimeStamp) 0x00000578          (AVP Value = Thu Jan  1 01:23:20 1970) 0x00000000      (AVP Value)  0x0000      (Reserved) 0x0008      (AVP Length) 0x0012              (AVP Type = TagType) 0x0003              (AVP Value = EPCC1G2)  0x0000      (Reserved) 0x0008      (AVP Length) 0x000F      (AVP Type = TagIDLen) 0x000C      (AVP Value = 96 bit)  0x0000      (Reserved) 0x0012      (AVP Length) 0x0011      (AVP Type = TagID) 0x300833B2DDD9014035050000  0x0000      (Reserved) 0x0008      (AVP Length) 0x0002      (AVP Type = ResultCode) 0x0000      (AVP Value = Success)