Brooks Automation TLG Transponder Reader System User Manual A5 E 2 2

Brooks Automation (Germany) GmbH RFID Division Transponder Reader System A5 E 2 2

Users manual

Page 1 of 222000-01-11Release 2.2LON Transponder ReaderTechnical  Reports
Hermos Technical ReportsRelease 2.1 Page 2 of 221SYSTEM DESCRIPTION 32IMPORTANT NOTES: 43HARDWARE 53.1 CONSTRUCTION 53.2 STANDARD HOUSING 73.3 TERMINAL CONNECTION 84TECHNICAL DATA 104.1 POWER SUPPLY AND CURRENT INPUT 114.2 ADDITIONAL INSTRUCTION FOR USE 115INSTALLATION DESCRIPTION OF THE LON-NETWORK 125.1 TRANSMISSION MEDIUM 125.2 NETWORK TOPOLOGY 126LICENSES AND CERTIFCATES 147WARRANTY AND LIABILITY 158READING AND WRITING RANGES 168.1 READING RANGE STICK ANTENNA 168.2 WRITING RANGE STICK ANTENNA 178.3 READING RANGE MICRO ANTENNA 188.4 WRITING RANGE MICRO ANTENNA 198.5 READING RANGE FRAME ANTENNA 208.6 WRITING RANGE FRAME ANTENNA 219ACCESSORIES 229.1 CABLING OF POWER AND LON 229.2 CONNECTION OF THE EXTERNAL SENSOR/ACTOR 229.3 POWER SUPPLY 22
Hermos Technical ReportsRelease 2.1 Page 3 of 221 System DescriptionThe HERMOS transponder reader system is used in the semiconductor industry forthe identification of the wafer-carrier. It is a high frequency identification systemusing the FM-transmission.The basic item is a transponder working as a forgery-proof electronic identity disc.The reader of the system sends an energy impulse via the antenna. The capacitorof the passive, battery-less transponder is charged by this impulse. After that, thetransponder returns a signal with the stored data.The total reading cycle takes less than 100 ms.As a sight-connection between transponder and reader is not absolutely necessary,the transponder can also be identified through non-metallic material.The HERMOS transponder reading unit is a LON-node. LON is a control networkfor distributed systems and has been developed by the US company Echelon. TheLONWORKS-technology corresponds to the SEMI (Semiconductor EquipmentMaterials International)-Standard (E54.6).The data received by the transponder reader are transmitted to equipment,terminalserver or host systems by the LON-network.
Hermos Technical ReportsRelease 2.1 Page 4 of 222 Important Notes:This device complies with Part 15 of the FCC Rules. Operation is subject to thefollowing two conditions:1) this device may not cause harmful interference , and2) this device must accept any interference received, including interference thatmay cause undesired operation.CAUTION:Changes or modifications not expressly approved by the party responsible forcompliance could void the user’s authority to operate the equipment.NOTE:This equipment has been tested and found to comply with the limits for a Class Bdigital device, pursuant to part 15 of the FCC Rules. These limits are designed toprovide reasonable protection against harmful interference in a residentialinstallation.This equipment generates, uses and can radiate radio frequency energy and, if notinstalled and used in accordance with the instructions,may cause harmfulinterference to radio communications. However, there is no guarantee thatinterference will not occur in a particular installation. If this equip-ment does causeharmful interference to radio or television reception, which can be determined byturning the equipment off and on, the user is encouraged to try to correct theinterference by one or more of the following measures:—Reorient or relocate the receiving antenna.—Increase the separation between the equip-ment and receiver.—Connect the equipment into an outlet on a circuit different from that to    which the receiver is connected.—Consult the dealer or an experienced radio/TV technician for help.
Hermos Technical ReportsRelease 2.1 Page 5 of 223  Hardware3.1 ConstructionSERVICE-key FuseControl-LEDred:SERVICEgreen:  READControl-moduleConnectionterminalScrew connectionfor antennaShield connectionfor antenna leadHF-moduleExternal input andoutputAttention:ALL ANTENNA RESONANT CIRCUIT COMPONENTS CAN CARRY HIGHVOLTAGE!Connection for ext.input and outputConncection forpower and LON-busOutput for antenna   C   C   S     -    +SXS1 XS2
Hermos Technical ReportsRelease 2.1 Page 6 of 22Control-LEDThe two-coloured control-LED (red/green) shows the actual operation status of thedevice.Red: The control-LED glows shortly red, if the SERVICE-button had been pushed.If the LED blinks red or glows red continuously, the device is unconfigured orapplicationless. In this case, please contact the manufacturer.Green: The control-LED glows shortly green, if the device tries to read or write. SERVICE-buttonThe SERVICE-button can be used to install the reader into the network.Terminal screw for antenna shieldingThe shield of the antenna has to be sticked on the terminal screw.Control-moduleThe control-module is the control unit of the device. On the module, there is thecontroller (Neuron-chip), a plug-in program memory (FlashEEPROM) and theFTT10-A transceiver for the communication on the LON-bus.HF-moduleThe HF-module is the analog part of the device. It triggers the antenna andtransmits the received data to the control-module.
Hermos Technical ReportsRelease 2.1 Page 7 of 223.2 Standard Housing
Hermos Technical ReportsRelease 2.1 Page 8 of 223.3 Terminal ConnectionBuilt-in male plug, plastic (supply and LON)PIN signal1+24V20V3LON4LON5shieldUp to serial-no. TLG-00-1999: Pin 5 (shield) has to be connected!Option: built-in female plug, metal (external sensor/actor)PIN signal1+24V Output20V3IN NPN4+5V5OUT LED12  345Sensor is not connected.34512positive logic                              negative logic+ 10..30VDC0 VType: NPNOutput Q+ 10..30VDC0 VType: NPNOutput QPlease advise in your order whichsensor logic will be used!
Hermos Technical ReportsRelease 2.1 Page 9 of 22For the actor signal a LED without a shunt (connection to PIN 4 and 5) is required.For the sensor a potential free contact (connection to PIN 2 and 3) or a 24V-sensor (3 wire version with npn-output, connection to PIN 1 to 3) is required.Important:Up to serial-no: TLG-00-1999For devices which have been delivered before the end of November 1998,please pay attention to the following when selecting the 24V-sensor:In open wiring condition, maximally +5V may be applied to the npn-output!
Hermos Technical ReportsRelease 2.1 Page 10 of 224 Technical DataParameter ValueOperation temperature 0 to +50°CStock temperature -25 to +70 °CPermissible humidity @ 50C° 25 - 80 %Transmitter frequency 134.2 kHzMax. transmitting level in 3m distance 104 dBµV/mTyp. period of charging impulse 50msMax. repeat of reading 4/sMax. repeat of program 1/sProtection mode IP 40Housing ABS or PPWeight (with rod antenna and presence sensor) about 440gFuse type TR4 500mA (T)
Hermos Technical ReportsRelease 2.1 Page 11 of 224.1 Power Supply and Current InputDescription min type max unitVoltage (proof against connecting tothe wrong terminal) 18 24 30 VDCCurrent with/without presence sensor(starting process excluded) 30 / 55 mAReading/writing impulserod antenna without/with presencesensormicro antenna without/with presencesensor160 / 185140 / 165mAmARemark to the power supply:During the starting process (charging of the capacitor in the input filter of thedevice), you have to ensure that the power supply does not cut off the outputcurrent. We recommend to use a power supply with stable current characteristicup to 0V output voltage (for example our part-no. SVG2,5).4.2 Additional Instruction for UseNever expose the device to a intense change in temperature. Otherwise, water ofcondensation can develop inside the device what can lead to damages.Never bend or extend the antenna cable or expose it to other mechanical loads.
Hermos Technical ReportsRelease 2.1 Page 12 of 225 Installation Description of the LON-NetworkThe installation can be carried out with the cables and distributors pre-manu-factured by HERMOS (see 6. Accessories). Your own cabling is also possiblewhen the following points are noticed.5.1 Transmission MediumThe bus cable is realized through an economy-priced twisted pair cable. Withcarried along operation voltage with 4 cores.For shielded cables, the shield has to be connected on both sides.Realization with optical fibre, radio and infrared is also possible.5.2 Network TopologyThere are two possiblities of network topology:-Free topology-Bus-topologyThe free topology allows a constellation in line-, star, ring- or tree-structure.So it is able to correspond to the geometrical demands.A mixed architecture is also possible.Only one connector is required.On account of the mode of transmission, it cannot be connected the wrong wayround.TReader or gatewayTerminator (bus terminationConnection cable (bus + power supply)T
Hermos Technical ReportsRelease 2.1 Page 13 of 22In the standard version, the devices are equipped with a FFT-10A transceiver.For the transceiver FTT-10 following data are applied:Cable type Max. length of node to nodeBelden 85102 500mBelden 8471 400mLevel IV, 22AWG 400mJY (St) Y 2x2x0,8 320mThe bus-topology consists of a main cable on which the individual nodes will beconnected with short stub lines. Terminators have to be connected on both ends ofthe cable.For the transceivers FTT-10 following bus lengthes are applied:Cable type Max. length of main cableBelden 85102 2700mBelden 8471 2700mLevel IV, 22AWG 1400mJY (St) Y 2x2x0,8 900mThe maximal length of a stub line is 3m.T TReader or gatewayTerminator (bus termination)Connection cable (bus + power supply)T
Hermos Technical ReportsRelease 2.1 Page 14 of 226 Licenses and Certifcates• BZT Number: G750733J• EC-Type Certification Registration Number: B132424J• FCC ID: N5GTLG
Hermos Technical ReportsRelease 2.1 Page 15 of 227 Warranty and LiabilityThe warranty period is 6 months and starts with the moment of the delivery of thedevice which has to be proved by invoice or other documents.The warranty includes the repair of all damages of the device, occurring within thewarranty period, which are evidently caused by faults of the material or productionaldefects.Not included into the warranty are damages caused by not prescribed connection,inappropriate handling and non-observance of the technical reports.
Hermos Technical ReportsRelease 2.1 Page 16 of 228 Reading and Writing RangesThese diagrams have been taken at optimal conditions.8.1 Reading Range Stick AntennaTransponder: 32 mm multipage glass transponderAntenna: HERMOS stick antenna________ Transponder parallel to antenna- - - - - - - -  Transponder 90° to antenna
Hermos Technical ReportsRelease 2.1 Page 17 of 228.2 Writing Range Stick AntennaTransponder: 32 mm multipage glass transponderAntenna: HERMOS stick antenna________ Transponder parallel to antenna- - - - - - - -  Transponder 90° to antenna
Hermos Technical ReportsRelease 2.1 Page 18 of 228.3 Reading Range Micro AntennaTransponder: 32 mm multipage glass transponderAntenna: HERMOS micro antenna________ Transponder parallel to antenna- - - - - - - -  Transponder 90° to antenna
Hermos Technical ReportsRelease 2.1 Page 19 of 228.4 Writing Range Micro AntennaTransponder: 32 mm multipage glass transponderAntenna: HERMOS micro antenna________ Transponder parallel to antenna- - - - - - - -  Transponder 90° to antenna
Hermos Technical ReportsRelease 2.1 Page 20 of 228.5 Reading Range Frame AntennaTransponder: 32 mm multipage glass transponderAntenna: HERMOS frame antenna________ Transponder parallel to antenna- - - - - - - -  Transponder 90° to antenna
Hermos Technical ReportsRelease 2.1 Page 21 of 228.6 Writing Range Frame AntennaTransponder: 32 mm multipage glass transponderAntenna: HERMOS frame antenna________ Transponder parallel to antenna- - - - - - - -  Transponder 90° to antenna
Hermos Technical ReportsRelease 2.1 Page 22 of 229 Accessories9.1 Cabling of Power and LON• Female plug, straight :  KBV-GK• Female plug, angled :  KBV-WK• Male plug, straight :  KSS-GK• Current connector with two cores:  KBV24• Bus-cable connector with two male plugs, 0.2m :  KVSS02• Bus-cable with two female plugs (0.5m, 1m, 2m, 4m, 6m, 8m, 10m) :BZK05, BZK10, BZK20, BZK40, BZK60, BZK80, BZK100• Y-cable: one female plug, two male plugs :  YKB2KS• Bus-cable with 1 female plug (0.5m, 1m, 2m, 4m, 6m, 8m, 10m) :BEK05, BEK10, BEK20, BEK40, BEK60, BEK80, BEK1009.2 Connection of the external Sensor/Actor• Male plug, metal :  KSS-GM• Angled male plug, metal :  KSS-WM• External optical coupler for top-hat rail installation (can be connected directly onthe LED, output data: 48V DC 100mA ) :  LDOP9.3 Power Supply• Power supply, input: AC 120-230 V, output: DC 24 V / 2.5 A:SVG2,5• Power supply, input: AC 120-230 V, output: DC 24 V / 4 A:SVG4Hermos Informatik GmbH Tel. +49-9279/991-910Gartenstrasse 19, D-95490 Mistelgau Fax +49-9279/991-900