Boston Scientific CRM312005 Model 3120 User Manual Draft Literature Labeling Review

Boston Scientific Corporation Model 3120 Draft Literature Labeling Review

Users Manual

Draft Literature/Labeling Review002169 Rev CYou are being asked to review product literature/labeling because of your particular expertise. To minimize the number of review cycles, please review the attached draft thoroughly and provide any comments, changes, or concerns at this time. • Please provide any comments on the attached draft by the due date indicated above.• A non-response will be taken to mean that you accept the draft content "as is." • Use the grid on the reverse side of this form to help focus your review efforts. • Your signature is not required.Note: After receiving comments and making any revisions that are required, Technical Communications will useWindchill to route a final version of this literature/labeling to obtain required electronic signatures. Reviewers are accountable for ensuring that they are trained on 028886, Cross-Functional Product Labeling Reviews, before reviewing and approving labeling. We appreciate your efforts and value your feedback. Thank you!Reason for review / Writer’s comments:Here is the updated ZOOM LATITUDE operator’s manual (US). The only changes since the last draft are as follows:•Pages 20: Moved paragraph and caution back to here; should not have moved with standards (Tech Comm).•Page 22: Added clarifying text to “printing stops” issue (Rick Stein, Engineering, and SCR 7048).•Page 34–35: Made title more generic, deleted introductory sentence since it is repeated below but with qualifiers, added subheads for each standard, moved notes up to the EMC section, deleted sections that belong elsewhere (paragraph and caution on page 20 and notes in EMC section), and changed FCC to subhead so it now falls under the Compliance Standards section (Tech Comm). Also, changed “applicable EMC standards” to “applicable por-tions of the electromagnetic compatibility (EMC) standards” for clarity (Rick Stein, Engineering); had to write out “EMC” because this is now first use of the acronym (Tech Comm).ProjectZOOM LATITUDE operator’s manual (US) - 357043-001 (dual antenna)Date sent: 2/28/05Date due: Tuesday, 3/01/05, 12:00 noonDraft Review Return to:Kathleen BriggsMail Stop:Department Mail StopReviewers For Tech Comm Use Only FYI Reviewers(Return not necessary)Mail StopRec’d OK Chgs TransEngineering Richard SteinEngineering Holli PheilEngineering Yogendra ShahEngineering Robert BartlowMarketing Amy GaalRegulatory Karen AlsopLegal Susan Thompson
Instructions For Review The table below was designed to help streamline the literature review process, to reduce the number of reviews per piece of literature, to reduce the amount of time you need to spend reviewing each piece, and to help you focus your attention while reviewing literature.Suggested Areas of Focus Legal Engineering Regulatory Affairs Marketing Clinical ProgramsTechnical ServicesReview cautions, warnings and notes. Are they appropriate, and are there any that are missing? xx x x xReview labeling for liability issues based on claims made in the labeling. x x xReview warranty information. x xReview labeling for any missing legal requirements. xReview copyright and trademark notations. x xReview product description, product handling (sterilization, shipping, storage, biological testing). xReview product specifications and units of measure (in tables and throughout text). xReview product features. Are the appropriate features highlighted and described correctly? xx xxReview illustrations. Are they appropriate to the corresponding text and labeled correctly? xxxReview tables and text relating to parameters, programmable values, nominal settings, tolerances, and product functions. xReview equipment hook-up procedures, lead-to-PG connections, etc. x x x xVerify that all references to other Guidant products are still correct and relevant. xx xxReview labeling for missing information (features, specifications, government requirements, legal requirements). xx xVerify the list of items packaged with the product. x xCompare the labeling to the system requirements specification, hazard analysis, and any labeling-related SCRs or change issues. xVerify the labeling against the clinical protocol and clinical study results. x xReview labeling for references to other products that affect other submissions. xProduct naming and description xDevice longevity and warranty information xReview that implant procedures are described correctly. xxVerify that information provided in the labeling is consistent with other related literature. xReview the risk section. Are all applicable risks listed? xReview labeling for clarity in device description and instructions for use. xReview tables and text relating to parameters, programmable values, nominal settings, tolerances, and product functions. x
Operator’s ManualZOOM® LATITUDE™Programming SystemMODEL 3120RESTRICTED DEVICE: Federal law (USA) restricts the sale, distribution, or use of this device to, by, or on the lawful order of a physician.Programmer/Recorder/Monitor (PRM)
CONTENTSDESCRIPTION AND USE   . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1Intended Use   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1Contraindications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1Adverse Effects   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2SYSTEM FEATURES  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2System Accessories  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3Optional External Printer   . . . . . . . . . . . . . . . . . . . . . . . . . .  3Optional External Monitor  . . . . . . . . . . . . . . . . . . . . . . . . . .  4PREPARING THE PRM FOR USE . . . . . . . . . . . . . . . . . . . . . .  4Prepare the Telemetry Wand  . . . . . . . . . . . . . . . . . . . . . . .  4Make External Cable Connections  . . . . . . . . . . . . . . . . . . .  5Start the PRM  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  6USING THE PRM  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7Startup Screen  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7Touchscreen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7Indicator Lights  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8ECG Display  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8Keys  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  9Monitoring/Recording Functions . . . . . . . . . . . . . . . . . . . .  11Using an External Recorder  . . . . . . . . . . . . . . . . . . . . . . .  12Using an External Printer  . . . . . . . . . . . . . . . . . . . . . . . . .  12Quick Start  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12The Utilities Menu on the Startup Screen . . . . . . . . . . . . .  13The Select PG Option on the Startup Screen . . . . . . . . . .  14Changing Parameter Values   . . . . . . . . . . . . . . . . . . . . . .  15MAINTENANCE AND HANDLING  . . . . . . . . . . . . . . . . . . . . .  16Loading the Paper   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  16Thermal Paper Storage   . . . . . . . . . . . . . . . . . . . . . . . . . .  17Cleaning the PRM   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  17Patient Data Disk  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  18Operation and Storage Conditions  . . . . . . . . . . . . . . . . . .  19PRM Storage   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  20Preventive Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . .  20
SERVICE   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  20ENVIRONMENTAL PROTECTION . . . . . . . . . . . . . . . . . . . . .  21WARRANTY INFORMATION  . . . . . . . . . . . . . . . . . . . . . . . . .  21ORDERING ACCESSORIES  . . . . . . . . . . . . . . . . . . . . . . . . .  21TROUBLESHOOTING  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  22EXTERNAL CABLE CONNECTIONS . . . . . . . . . . . . . . . . . . .  25Surface ECG Connections  . . . . . . . . . . . . . . . . . . . . . . . .  26Patient–Recorder–PRM Connection   . . . . . . . . . . . . . . . .  27Patient–PRM–Recorder Connection   . . . . . . . . . . . . . . . .  28Parallel Connection   . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  29Suggested Electrode Locations  . . . . . . . . . . . . . . . . . . . .  30LABEL SYMBOLS   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  31SAFETY AND ELECTROMAGNETIC COMPATIBILITY COMPLIANCE STANDARDS  . . . . . . . . . . . . . . . . . . . . . . . . .  34Safety Standards   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  34Electromagnetic Compability Standards . . . . . . . . . . . . . .  34Medical Device Directive   . . . . . . . . . . . . . . . . . . . . . . . . .  34Federal Communications Commission (FCC)   . . . . . . . . .  35ELECTROMAGNETIC EMISSIONS AND IMMUNITY  . . . . . .  36SPECIFICATIONS (Nominal)  . . . . . . . . . . . . . . . . . . . . . . . . .  40
1DESCRIPTION AND USEThe ZOOM® LATITUDE™ Programming System, which includes the Model 3120 Programmer/Recorder/Monitor (PRM), is a portable cardiac rhythm management system designed to be used with Guidant implantable pulse generators.Intended UseThe Model 3120 PRM is intended to be used as a complete system to communicate with Guidant implantable pulse generators. The software in use controls all communication functions for the pulse generator. For detailed software application instructions, refer to the System Guide for the Guidant pulse generator being interrogated. ContraindicationsThe Model 3120 PRM is contraindicated for use with any pulse generator other than a Guidant device.For contraindications for use related to the Guidant pulse generator, refer to the System Guide for the Guidant pulse generator being interrograted.PrecautionsGeneral• Use only the appropriate Guidant programmers equipped with the appropriate software to program Guidant pulse generators.• The Model 3120 PRM is designed to be used only with the Model 6577 Sterilizable Telemetry Wand. Do not use the Model 6575 Telemetry Wand with the Model 3120 PRM.• Use the supplied stylus with the Model 3120 PRM; the use of any other object could damage the touchscreen.NOTE:  Use of the stylus is recommended for accuracy.Preparation for Use• Remove the telemetry wand from all packaging material before sterilizing it.• Avoid establishing telemetry communication between the PRM and the pulse generator when the PRM is in close proximity to monitors, high-frequency electrosurgical equipment, and strong magnetic fields, such as magnetic resonance imaging (MRI) devices. The telemetry link may be impaired and, in the case of MRI, may interfere with the PRM.Maintenance and Handling• Do not use an abrasive cloth or volatile solvents to clean any portion of the PRM.• Keep disks away from magnets and magnetized objects, including telephones, power-supply adapters, and monitors.• Do not place a magnet on the PRM.
2• The PRM is not water-proof or explosion-proof. It should not be used in the presence of flammable gas mixtures including anesthetic mixture with air, oxygen, or nitrous oxide.Adverse EffectsNone known.SYSTEM FEATURESThe PRM communicates with Guidant pulse generators via telemetry using the Guidant Model 6577 Sterilizable Telemetry Wand to perform the following functions:• Interrogates the programmable pulse generator.• Programs detection and therapy parameters for an implantable Guidant pulse generator.• Displays, records, and stores patient data and allows the physician to evaluate alternative prescription modes.• Stores patient data that can be recalled later in the patient session for analysis. (For certain applications only)• Stores patient data on a disk that can be accessed at later sessions.• Generates printed reports that detail pulse generator functions, stored patient data, and test results.• Allows the physician to perform tests in an electrophysiology (EP) laboratory, in an operating room, in an emergency room, or at a patient’s bedside.In addition, the PRM has the following capabilities:• Provides a direct interface between an external stimulator and an implanted Guidant pulse generator for programmed electrical stimulation (PES) during EP studies.• Provides use without device telemetry as an electrocardiogram (ECG) display and recorder. • Simultaneously prints real-time surface ECG and telemetered signals (intracardiac electrograms and event markers) via the internal printer/recorder.The PRM is equipped with the following features:• PRM function keys, including PROGRAM, STAT PACE, STAT SHOCK, DIVERT THERAPY, and INTERROGATE.• Printer/recorder function keys, including paper speed, calibrate, zero to baseline, and paper feed.• Touchscreen with tethered stylus.• Color display screen.• One floppy disk drive.• Internal hard drive.
3• High-speed four-inch (110 mm) thermal printer/recorder.• Connections for slaved stimulation via an external signal source. (For certain applications only)• Connection for recording data on an external FM tape recorder or strip chart recorder or both.• Connection for an optional external printer.• USB port for software installation by Guidant personnel.•ZIP telemetry, which is a wandless, two-way radio frequency (RF) communication option that allows the PRM system to communicate with the pulse generator.NOTE:  This feature is not available for all pulse generators. For more information, refer to the System Guide for the Guidant pulse generator being interrogated.System AccessoriesThe ZOOM LATITUDE Programming System consists of the Model 3120 PRM.Other accessories for use with the PRM that can be ordered from Guidant include the following:• Model 3122 Antenna• Model 3130 Accessory Kit• Model 2902 AC Power Cord• Model 6577 Sterilizable Telemetry Wand• Model 6627 Patient Data Disks (10)• Model 6750 Surface ECG Patient Cable• Model 6979 Printer Paper (4)• Model 6809 Accessory Kit• Model 6892 Controller-Stimulator Cable• Model 6924 External Recorder Cable• Model 6629 ECG–BNC Slave Cable• Model 6930 Stimulation Input Cable Adapters• Model 6934 Phono-BNC Adapters• Model 6977 VGA Extension CableWARNING:  The use of any cables or accessories with the Model 3120 PRM other than those specified by Guidant in this manual may result in increased emissions or decreased immunity of the Model 3120 PRM.Optional External PrinterThe use of an external printer is optional. Only compatible external printers that have been tested and qualified for use should be used with the Model 3120 PRM. Contact your Guidant sales representative to determine which printer(s) can be used. CAUTION:  Although the external printer meets leakage-current requirements for commercial products, it may not meet the reduced
4leakage requirements for medical products. Consequently, the external printer must be kept outside the patient environment (at least 4.9 feet [1.5 meters] away from the patient).Optional External MonitorThe use of an external monitor is optional. Contact your Guidant sales representative to determine which monitor(s) can be used.CAUTION:  Although the external monitor meets leakage-current requirements for commercial products, it may not meet the reduced leakage requirements for medical products. Consequently, the external monitor must be kept outside the patient environment (at least 4.9 feet [1.5 meters] away from the patient).PREPARING THE PRM FOR USEPrepare the Telemetry Wand1. If the telemetry wand is to be used in a sterile field when using the PRM, it first must be sterilized with ethylene oxide or steam. To sterilize it, follow the instructions in the product literature for the wand. CAUTION:  Remove the telemetry wand from all packaging material before sterilizing it.2. Plug the telemetry wand into the connector on the right side panel of the PRM (Figure 1).CAUTION:  Avoid establishing telemetry communication between the PRM and the pulse generator when the PRM is in close proximity to monitors, high-frequency electrosurgical equipment, and strong magnetic fields, such as MRI devices. The telemetry link may be impaired and, in the case of MRI, may interfere with the PRM.Figure 1. Right side panel of the PRM.ECG ConnectorTelemetry Wand ConnectorAnalog Output ChannelStimulator Inputs Air IntakeAntenna for ZIP telemetry
5WARNING:  The Model 3120 PRM may be interfered with by other equipment, even if that other equipment complies with the International Special Committee on Radio Interference (CISPR) emission requirements.Make External Cable Connections1. Connect the Model 6750 Surface ECG Patient Cable to the ECG connector on the right side of the PRM (Figure 1). This patient connection is electrically isolated. Attach the surface electrodes to the patient in a standard three-wire or five-wire configuration.NOTE:  The ECG subsystem may be sensitive to high-frequency ambient noise when the ECG inputs are not terminated.2. Connect the Model 6924 External Recorder Cable to the analog output channel on the right side of the PRM (Figure 1). Connect the other end to the multichannel recorder or external strip chart recorder. The Model 3120 PRM has high-level analog outputs.3. Connect the Model 6892 Controller-Stimulator Cable to the pacing stimulation source connector marked “Stimulator Input” on the right side of the PRM (Figure 1) and then into the corresponding terminal on the electrical stimulation source.4. (Optional) Connect the external printer to the PRM using the parallel cable provided with the printer (Figure 2). The external printer must be connected and activated to allow external reports to be printed.5. (Optional) Connect the external monitor to the PRM using a standard VGA cable (Figure 2). The Model 6977 VGA Extension Cable is available from Guidant as an accessory.NOTE:  If the PRM is in close proximity to high-frequency electrosurgical equipment, the surface ECG traces may exhibit noise interference. Refer to “TROUBLESHOOTING” on page 22 for corrective action.
6Start the PRMPerform the following steps to start the PRM:1. Connect the power cord into the alternating current (AC) connector on the rear panel (Figure 3).2. Plug the power cord into the appropriate AC outlet.3. Raise the screen to a comfortable viewing angle.4. Press the On/Off button (Figure 2).5. Wait for the Guidant startup screen (Figure 4) to appear.WARNING:  The Model 3120 PRM should not be used adjacent to or stacked with other equipment. If adjacent or stacked use is necessary, the Model 3120 PRM should be checked for normal operation in that configuration.Figure 2. Left side panel of the PRM.Figure 3. Rear panel of the PRM.On/Off ButtonExternal VGA Monitor ConnectorExternal Printer ConnectorUSB PortsGrounding Connector AC Connector
7USING THE PRMStartup ScreenThe startup screen (Figure 4) displays the following information:• The Utilities button allows access to programmer information and setup functions prior to accessing the application software.• The Select PG button allows the desired application to be chosen and started.• The ECG icon changes the screen display to an ECG display available for patient diagnosis.• The heart-rate indicator displays the intrinsic ventricular rate of the patient.•The Quick Start® button is an automated method for starting the appropriate application.• The bottom left corner of the screen displays the date, time, and programmer information.TouchscreenThe Model 3120 PRM has a touchscreen. You can select a button or icon on the touchscreen by touching the desired item with the stylus attached to the PRM and lifting the stylus from the screen. Only one button or icon may be selected at a time. Menu and parameter selection buttons will activate when selected; the buttons in the parameter value palettes will activate when the stylus is lifted from the screen. CAUTION:  Use the supplied stylus with the Model 3120 PRM; the use of any other object could damage the touchscreen.Figure 4. The startup screen is displayed when the programmer is powered On.ButtonsHeart-rateIndicatorECG Icon
8NOTE:  Use of the stylus is recommended for accuracy.Indicator LightsThe Model 3120 PRM has three indicator lights on the upper left corner, above the screen:ECG DisplayTo display surface ECG signals on the PRM without device interrogation, select the ECG icon on the startup screen (Figure 5). Connect the patient leads; for instructions on proper patient cable connections, refer to “EXTERNAL CABLE CONNECTIONS” on page 25. The PRM can display three surface traces of up to six limb leads or one chest lead. The top displayed lead will be annotated with the pacing spike marker if that feature is selected. To display the pacing spike markers correctly, the Lead II electrodes must be connected to the patient regardless of which lead is displayed. The heart-rate indicator in the upper-right corner of the startup screen will display the intrinsic ventricular rate as the trace runs.WARNING:  Operation of the Model 3120 PRM with physiological signals that are lower than the minimum detectable amplitude may cause inaccurate results. For details about the minimum amplitude, see Table 8 on page 40.Symbol Indicator Light FunctionZIP telemetryLit when ZIP telemetry has been established and interrogation or programming of ZIP-enabled PGs is occurring.Inductive telemetryLit when inductive, wanded telemetry has been established and interrogation or programming is occurring.On Lit when the PRM is On.
9The following screen buttons can be used to change the values and appearance of the traces:•Lead Selection Buttons—Select the lead traces to be displayed.•Speed Buttons—Select the desired speed button on the ECG display: Pause (||) (to freeze the trace), Play (>), or Fast-Forward (>>).•Printed Surface Gain—Select the appropriate value to adjust the surface gain of the traces that are captured on printouts.•Filter—Select On to minimize noise on the surface ECG.•Pacing Spike Display—Select On to show detected pacing spikes, annotated by a marker on the top waveform.NOTE:  The values as set up on the startup screen will be the defaults used for the application traces. The corresponding values can be changed from the Trace Selections screen while in the application. For detailed application programming instructions, refer to the System Guide for the Guidant pulse generator being interrogated.KeysFor specific instructions on how to operate the PRM keys and use the telemetry wand, refer to the System Guide for the Guidant pulse generator being interrogated. General key functions are summarized below in Table 1. The key pad on the right side of the PRM is shown in Figure 6.Figure 5. The ECG screen, as accessed from the startup screen.Speed ButtonsLead Selection ButtonsHeart-Rate IndicatorMenu Buttons             ECG Icon
10Table 1.  Key FunctionsLeft side of key pad:0 (stop), 10, 25, 50, and 100 mm/sec (paper-speed keys)Press the speed keys to specify the paper speed for the internal printer/recorder. The printout will show the date and time, lead(s) being printed, gain setting, chart speed, and filter setting. To stop the printer/recorder, press the speed key labeled “0” (zero).Press the paper-feed key to scroll the printer paper on the internal printer/recorder.Press this key to cause the internal printer/recorder to print a one-mV calibration pulse.Press this key to force the trace back to the baseline after a defibrillation shock.Right side of key padPress STAT PACE when in telemetry communication with the pulse generator to program predetermined parameters for emergency bradycardia pacing.Press DIVERT THERAPY when in telemetry communication with the pulse generator to divert tachycardia therapy delivery.Press STAT SHOCK when in telemetry communication with the pulse generator to program predetermined high-energy parameters for emergency shock delivery.STAT PACEDIVERT THERAPYSTAT SHOCK
11Monitoring/Recording FunctionsSurface ECGPressing any speed key will run a surface ECG if the surface ECG patient cable is connected to the PRM and electrodes are attached to the patient (unless a report is being printed). For detailed instructions, refer to “ECG Display” on page 8.Intracardiac ElectrogramIntracardiac electrograms may be printed or displayed and event markers may be printed by the PRM. For detailed instructions, refer to the System Guide for the Guidant pulse generator being interrogated.Press PROGRAM when in telemetry communication with the pulse generator to transmit new parameter values to the pulse generator.Press INTERROGATE when in telemetry communication with the pulse generator to obtain information stored in the pulse generator’s memory.Figure 6. Model 3120 PRM right-side keypad.Table 1.  Key FunctionsPROGRAMINTERROGATESTAT PACE STAT SHOCKDIVERT THERAPYPROGRAM INTERROGATE
12Using an External RecorderTo view the surface ECG traces on an external recorder, press the desired speed key on the external printer/recorder while the traces are displayed on the PRM screen. See “EXTERNAL CABLE CONNECTIONS” on page 25 for instructions on connecting the PRM to the external recorder. Refer to the external recorder manual for instructions specific to its operation.Using an External PrinterIf supported by the software application currently running, an optional external printer can be used. To print reports to an external printer, first connect the printer to the Model 3120 PRM using the parallel cable. The cable connects the external printer to the PRM via the external printer connector (Figure 2). The external printer must be connected and activated to allow external reports to be printed. For more information, see “Optional External Printer” on page 3.NOTE:  Equipment connected to the serial port and other external connections must comply with the respective IEC standards (e.g. IEC 950 for data processing equipment and IEC 601-1 for medical equipment). Furthermore all configurations shall comply with the system standard IEC 601-1-1. Everybody who connects additional equipment to the signal input part or signal output part configures a medical system, and is therefore responsible that the system complies with the requirements of the system standard IEC 601-1-1. If in doubt, consult Guidant Technical Services or your local Guidant sales representative.Quick StartThe Quick Start button is used to automatically identify and interrogate the implanted pulse generator. Place the telemetry wand over the pulse generator, and select the Quick Start button. A message window will appear, indicating one of the following conditions, based on the implanted device:•Application Startup in Progress—If the software for the implanted device is installed on the PRM, the PRM will identify the device, open the correct application, and automatically interrogate the pulse generator.•Software not installed—If the software application for the implanted device is available for the PRM but not installed on it, a message window will appear, identifying the device and stating that the software is not installed on the PRM.•Software not available on PRM—If an older model of Guidant device is identified, a message window will appear, informing the user that he or she must use a Model 2035 or 2901 programmer to interrogate and/or program the device. The model number of the software module or application will also be identified.
13•PG not identified—If a non-Guidant or one of certain older models of Guidant pulse generators is implanted, a message window will appear, notifying the user that the wand is out of range, telemetry noise is present, or the device is not identified.To access the demonstration (DEMO) mode (or the Read Disk feature, which is available in some applications), use the Select PG button at the top of the screen to choose the pulse generator family instead of using the Quick Start button.The Utilities Menu on the Startup ScreenIf desired, before accessing the pulse generator software application, the version numbers of the system software and installed software applications can be displayed, the programmer clock can be modified, the institution name can be changed, and data disks can be copied and formatted. (To access the startup screen from within a software application, select the Quit option from the Utilities button to exit the software application and return to the startup screen.)1. On the startup screen, select the Utilities button.2. Select the About option to view the version numbers of the system software and application software residing on the programmer.3. Select the Set Programmer Clock option to change the programmer date and time (24-hour clock), which is displayed in the lower left corner of the startup screen. The Set Date and Time window will appear (Figure 7).a. Change the values by selecting an up or down arrow. b. To reset the seconds display to zero, select the box containing two digits (shown as 00 in Figure 7). c. When the desired values are displayed, select the Set Programmer Clock button to confirm the new date and time. (To cancel any changes prior to confirming the new values, select the Cancel button; the window will close without changing the values.)NOTE:  The programmer and pulse generator clocks may be synchronized once the application is accessed. Refer to the “Set Figure 7. The Set Date and Time window.
14Clock” section in the System Guide for the Guidant pulse generator being interrograted.4. Select the About option to update the institution name. If the programmer has been moved to a different institution, the name of the institution as it appears on the startup screen can be changed. For instructions on entering new data, refer to “Changing Parameter Values” on page 15.NOTE:  The institution name also is displayed in the heading of printed reports.5. Select the Format Disk option to erase all data from a Model 6627 Patient Data Disk and reformat it so new data can be saved on the disk. Follow the directions displayed in the message windows. 6. Select the Copy Disk option to copy patient data from one disk (the source disk) to another (the destination disk). Do not use a destination disk that contains patient data, because the existing data will be lost. Follow the directions displayed in the message windows. (This function performs in the same manner as the Copy Disk function of the software application; refer to the System Guide for the Guidant pulse generator being interrogated.)The Select PG Option on the Startup ScreenThis option allows the software application to be selected manually. Use this option to access the DEMO mode (or the Read Disk feature, which is available in some applications). (You can also use this option to interrogate a pulse generator, but you may find it more convenient to use the Quick Start feature described earlier in this manual.)1. To access the desired software application without using the Quick Start feature, select the Select PG button.2. The names of the available software applications will appear. Select the applicable software application. Each application communicates with its pulse-generator family.3. A screen will appear with options to interrogate the pulse generator or use the DEMO mode. (Some applications will also display the option to read a patient data disk.)4. To become familiar with the software without interrogating a pulse generator, select the DEMO button; the main application screen will be displayed and the DEMO logo will appear at the top of the screen. The screens displayed during the DEMO mode reflect the software application family’s device features and programmable values.NOTE:  STAT PACE, STAT SHOCK, and DIVERT THERAPY commands are functional in DEMO mode only if the telemetry wand is positioned over the pulse generator.5. To exit the DEMO mode, depending on which application you are using, select the New Patient or Quit options from either the Utilities
15button or the Exit button. For more information about these options, refer to the System Guide for the Guidant pulse generator being interrogated.6. To proceed with an interrogation session or read data from a patient data disk (which is a feature that is available in some applications), refer to the System Guide for the Guidant pulse generator being interrogated.Changing Parameter ValuesThe screens for many of the features contain parameter information, including parameter names, values for the present parameter settings, value boxes to accommodate value changes, and buttons to cancel changes. Many screens display two columns next to the parameter names: the Present column and the Change column. The Present column displays the currently programmed value for each parameter, and the Change column displays value boxes that allow the clinician to make changes to the parameters. If a particular parameter is not applicable in the current mode, dashes will be displayed in the Present column. If a particular parameter is not applicable to the mode in the Change column, that parameter’s value box is not displayed.Palette Window: To change the parameter values, first select the appropriate parameter’s value box in the Change column. A palette window will appear (as shown in Figure 8). Select a value from the palette window (by touching the desired value and lifting the stylus from the screen). Touching the screen outside a window will close it without making a selection. When changes have been made to parameter values, the data appear in the Change box until programmed into the pulse generator.In some screens (e.g., Patient Data screens), data are not displayed in Present and Change columns. These screens display value boxes that Figure 8. Types of windows enabling value changes.Palette Window Keyboard Window
16require unique data to be entered. Typically, the data are entered from a keyboard window (as shown in Figure 8). The values entered will remain in the value boxes when programmed; they will not move from a Change column to a Present column.Keyboard Window: Touch the first character of the new value; it will appear in the data-entry box in the graphic keyboard. Continue until the entire new entry appears in the box. To delete one character at a time, starting with the last character, select the left arrow key on the graphic keyboard. Each time the left arrow key is selected, a character will be deleted in the box. To cancel any deletions or additions just made, select the Cancel Changes button. When all the appropriate characters have been selected, select the Close button on the graphic keyboard.NOTE:   If, when the graphic keyboard initially appears, it contains data in the value box, select the Clear button to delete all the characters in the value box.Copy button: On screens that contain a Copy button, you can simply copy parameter values from one screen to another. Select the Copy button. A window will appear with a Copy From column and a Copy To column, with buttons below the columns. Select the desired buttons in both columns, and then select the Copy button.To program the device, follow the instructions in the System Guide for the Guidant pulse generator being interrogated.NOTE:  If additional parameters require reprogramming, repeat these steps. Multiple parameter changes can be programmed at one time (batch programming).MAINTENANCE AND HANDLINGLoading the PaperThe internal printer/recorder uses four-inch wide (110 mm) thermosensitive printing paper. Model 6979 Printer Paper refills can be ordered from Guidant.Use the following procedure to load paper into the internal printer/recorder:1. Open the printer door.2. If any sheets from the previous pack remain but did not feed, remove them and rotate the roller with clean fingertips to remove any small pieces of paper still under the printhead.3. If the paper is still enclosed in its original plastic packaging, remove this covering from the pack.4. Orient the pack such that the pagination mark (which is the small black box that is visible inside the pack if you lift up the top sheet of paper) is located nearest to the front of the programmer. (For a visual
17of how to orient the paper, refer to the paper liner inside the PRM.) Insert the pack into the printer/recorder.NOTE:  You must use paper with pagination markings. Paper will not paginate properly if paper does not have markings.5. Unfold one sheet of paper, and allow the unfolded sheet to lie flat across the well of the stylus.6. Close the printer door completely. The printer/recorder will automatically begin the paper-loading sequence and will stop at the first pagination mark after paper is detected. If the paper’s edges are wrinkled, wait for four or five pages to feed through the printer. The printer will self-align the paper to its proper position.The printer/recorder is now ready to resume printing.For information regarding loading paper into the optional external printer, refer to the user manual for the printer.Thermal Paper StorageStore the heat-sensitive paper for the internal printer/recorder in a cool, dark environment. Do not attempt to erase the printer/recorder paper. Printed paper will last approximately 30 days under direct fluorescent light. To ensure the permanence of a patient’s record, store the printed paper away from direct sunlight, heat, or fumes from organic compounds. Storage temperatures above 149°F (65°C), sustained exposure to direct sunlight, or exposure to high humidity, acetone, ammonia, alcohols, or other organic compounds may cause the paper to discolor.NOTES:  • If printed reports are to be kept for prolonged periods, you must make a photocopy of the thermosensitive paper as this paper is not intended for long-term retention and will lose legibility over time. • Some brands of adhesive tape applied to a printed report will fade the printing after 30 days.Cleaning the PRMClean the housing and touchscreen of the PRM with a soft cloth lightly dampened with water.Clean the printer/recorder with a dry, soft brush to eliminate dust and particles that may accumulate during printing and storage.CAUTION:  Do not use an abrasive cloth or volatile solvents to clean any portion of the PRM. The cables used with the PRM are not sterile when packaged. When necessary, clean the cables with a soft cloth dampened with a mild cleaning solution (e.g., Liqui-nox for the sterilizable telemetry wand; Borax or a 1:10 bleach solution for other cables). Using the same method,
18wipe them completely with sterile water and towel- or air-dry. DO NOT use an ultrasonic cleaner NOR immerse the cables. Clean the sterilizable telemetry wand in the same manner, allowing no fluids to enter the wand cavity. See “Prepare the Telemetry Wand” on page 4 for sterilization instructions.Patient Data DiskThe Model 6627 Patient Data Disk must be inserted with the arrow on the top left side and pointing into the disk drive (Figure 9).Be certain that the write-protect tab is closed on the disk (Figure 10). Insert a patient data disk firmly into the disk drive on the right side of the PRM until the disk ejection button protrudes.NOTE:  For complete instructions on using the patient data disk, refer to the System Guide for the Guidant pulse generator being interrogated.Caring for DisksFloppy disks can be damaged easily, making them unusable. To prevent damage to the disks:• Write on labels before applying them to disks.• Use only a felt-tipped pen to write on a label that is already applied to a disk.• Keep food and beverages away from disks and away from the PRM.Figure 9. Disk drive on the right side of the PRM.Figure 10. Patient Data Disk with write-protect tab closed.Arrow on top and pointing to the disk driveDisk Drive Disk Ejection ButtonPatient Data Disk Write-protect tab closed(black tab covering hole)Sliding Shutter
19• Keep disks away from heat or direct sunlight. Disks should be stored at temperatures between 5°C and 60°C (41°F and 140°F).• Keep disks dry and stored in a dry area (with a relative humidity between 8 percent and 80 percent).• Do not bend disks.• Do not attach paper clips, staples, or rubber bands to disks.• Do not try to open the sliding shutter that covers the disks (Figure 10).• Never touch the exposed disk area beneath the sliding shutter.NOTE:  The write-protect tab must be closed in order to record data to the disk and to print reports. If data cannot be recorded to the disk, check to see that the tab is positioned to cover the hole (Figure 10).CAUTION:  Keep disks away from magnets and magnetized objects, including telephones, power supply adapters, and monitors.Operation and Storage ConditionsThe Model 3120 PRM requires careful handling. The hard-disk drive and the floppy-disk drive must be protected from abusive handling. To protect the PRM from damage:• Do not turn off the PRM while the drive is accessing data.• Do not subject the PRM to abusive shocks or vibrations.• When transporting the PRM from a cold environment to a warm environment, allow the PRM to warm to ambient temperature before use.• Do not place heavy objects on the PRM surface when closed or when in operation.• Do not place a magnet on the PRM.• Do not pour or splash liquid into or onto the PRM.• Do not strike, scratch, nick or otherwise abuse the touchscreen surface.• Do not disassemble the PRM.• Remove any disks from the drive prior to transporting the PRM.• Turn off the PRM, close all covers and doors and put down the antenna prior to transporting the PRM. • Unplug all external cables and cords prior to transporting the PRM.Operate the PRM within a temperature range of 50°F to 95°F(10°C to 35°C) and a humidity between 25 percent and 95 percent. Transport and store the PRM at temperatures between –40°F and 158°F (–40°C and 70°C), humidity of 25 percent to 95 percent, and pressure of 7.252 psi to 15.374 psi (50 kPa to 106 kPa). If the PRM has been stored in cold conditions (less than 50°F [10°C]), turn it on and let the fan run for at least one hour before use.
20The PRM is capable of continuous operation and will not shut off automatically if it is unused for an extended time or if it runs out of paper. Keep the air intake and outlet free from obstruction.CAUTION:  The PRM is not water-proof or explosion-proof. It should not be used in the presence of flammable gas mixtures including anesthetic mixture with air, oxygen, or nitrous oxide.PRM Storage1. If using a patient data disk, remove disk from the disk drive by pressing the disk ejection button (Figure 9), and store the disk in a safe place.2. Exit the current software application.3. Press the On/Off button to turn off the power (Figure 2).NOTE:  Before unplugging the power cord to move the PRM, always exit the software application and press the On/Off button to turn off the PRM. 4. Unplug the power cord from the wall.5. Unplug the cables from the back and side panels and other equipment.6. Lower the screen until the front latch locks in place.NOTE:  The programmer is not intended to be rested or stored in an upright position (resting on rear panel with handle on top).Preventive MaintenanceThe user should inspect and/or test the following at regular intervals:• Mechanical and functional integrity of cables and accessories.• Mechanical and functional integrity of the PRM.• Legibility and adherence of the PRM’s labels.• Earth resistance to 0.1 ohms.• Earth leakage current to 500 microamperes, NC; 1,000 microamperes, SFC.• Patient leakage current to 10 microamperes, NC; 50 microamperes, SFC (per EN 60601-1 as referenced earlier in this manual).• Startup screen appears a few seconds after the user turns on the PRM.The PRM contains no user-accessible fuses or batteries.SERVICEFor questions regarding operation or repair of the PRM, call the nearest Guidant representative or call Guidant Technical Services at the phone number on the back cover of this manual. The PRM must be serviced by Guidant personnel only.This section should not have moved with the standards.
21If the Guidant PRM malfunctions and requires repair, help to ensure efficient service by following these guidelines:1. Leave the configuration of the instrument exactly as it was at the time of malfunction. Contact the nearest Guidant representative or call Guidant Technical Services at the phone number on the back cover of this manual.2. Write a detailed description of the malfunction(s).3. Save printouts or other materials that illustrate the problem.4. If the PRM must be returned to Guidant for service, pack it in the shipping container in which it was received or in a shipping container provided by Guidant.5. Send the PRM to Guidant at the address on the back cover of this manual.For problems or questions that arise regarding operation or repair of the optional external printer, contact the printer manufacturer or agent.ENVIRONMENTAL PROTECTIONReturn the programmer to Guidant at the end of its useful life for appropriate disposal.WARRANTY INFORMATIONA limited one-year warranty and a warranty registration card for the Guidant PRM is packaged with the PRM. Unless otherwise agreed, the PRM remains the property of Guidant and Guidant must perform all necessary servicing and repair work.ORDERING ACCESSORIESTo order accessories, contact the nearest Guidant sales representative or contact Guidant Corporation at the address or phone number on the back cover of this manual.
22TROUBLESHOOTINGIf the PRM does not operate properly, check that electrical cords and cables are securely connected and that cords and cables are in good working order (i.e., free of visible defects). Table 2 indicates possible causes and corrective actions for PRM problems. For external printer problems, refer to the manual for the external printer.Table 2.  Possible Causes and Corrective Actions for PRM ProblemsSymptom Possible Cause Corrective ActionInternal printer/recorder does not functionNo AC line voltageCheck that power cord is plugged securely into the rear panel of the PRM.Change to a different electrical outlet.Paper jam Clear paper path of any obstruction.No paper Add paper.Internal printer/recorder: paper-feed problemsPaper misaligned Reload paper.Paper-feedobstruction Clear obstruction from around the paper supply.Internal printer/recorder: no print visiblePaper loaded upside downReload paper. (See “Loading the Paper” on page 16.)Internal printer/recorder: printing stopsApplication did not handle print requestIf the touchscreen is responsive, select the Utilities button. From the Utilities menu, select Quit. In the window that appears, select Cancel Printing and then select Close. Turn on the programmer and try printing any incomplete items again.If the touchscreen is not responsive, turn off the programmer. Turn on the programmer and try printing any incomplete items again.External printer does not functionNo paper, paper jam, printer door open, toner cartridge not installed properly, printer power not On, printer not connectedConsult the manual for the external printer to determine the issue.
23No analog outputUsing incorrect output port and/or connectionsRecheck connection of the Model 6924 External Recorder Cable.Patient data disk errorUsing disk created for a previous model of PRM or unformatted floppy diskUse only Guidant Model 6627 Patient Data Disks.Write-protect tab open Close write-protect tab.Noise problems: ECGImproper patient connectionsRecheck patient leads for adequate skin contact and correct limb lead placement.Excessive radio emissions from equipmentCheck surrounding area for electrical equipment that is powered on and not needed. Move unneeded equipment away from patient and/or PRM, or turn off unneeded equipment. Consult ECG textbooks for additonal ECG techniques.Telemetry: no communicationIncorrect application software or incorrect PRM for pulse generatorInstall proper application software for pulse generator in use.Incomplete telemetry communicationReposition wand over the device; repeat interrogation.Te l em e tr y:  intermittent communicationIncorrect telemetry wandUse only the Guidant Model 6577 Sterilizable Telemetry Wand.Excessive radio emissions from equipmentCheck surrounding area for electrical equipment that is powered on and not needed. Move unneeded equipment away from patient and/or PRM, or turn off unneeded equipment.Incomplete telemetry communicationReposition wand over the device; repeat interrogation.Displayed clock does not consistently keep time after settingLow battery Return to Guidant for replacement of clock battery.Table 2.  Possible Causes and Corrective Actions for PRM ProblemsSymptom Possible Cause Corrective Action
24Programmer not respondingProgrammer not functioningTurn off programmer, and then turn on programmer. If this does not correct the issue, contact Guidant Technical Services at the phone number on the back cover of this manual.Table 2.  Possible Causes and Corrective Actions for PRM ProblemsSymptom Possible Cause Corrective Action
25EXTERNAL CABLE CONNECTIONSThe following cables are required for use with the Model 3120 Programmer/ Recorder/Monitor when using the configurations described in this section.• Model 6924 External Recorder Cable: a six-channel DIN – six BNC cables (color-coded and numbered) for connection of the PRM analog output signals to another strip chart recorder or monitor.• Model 6750 Surface ECG Patient Cable: a six-pin amphenol ECG cable for connecting the patient directly to the PRM.• Model 6629 ECG–BNC Slave Cable: used for input of patient ECG signals to the PRM from an external monitor or recorder.• Model 6577 Sterilizable Telemetry Wand.The PRM also has two adapter kits that adapt cables with BNC connectors to fit other sockets:• Model 6930:  BNC–dual banana plug                      BNC–pin tip                      BNC–alligator clip adapters• Model 6934:  BNC–phono adapterRefer to Figure 11 for cable connections.Figure 11. Cable connections for the Model 3120 PRM (right side panel).123456External Recorder Cable:Channel 1 (red) - surface ECGChannel 2 (orange) - telemetered signal 1Channel 3 (green) - telemetered signal 2Channels 4, 5, 6 - not activeTelemetry Wand ConnectorPatient ECG Cable orECG–BNC Slave CableTelemetry Wand Analog Output Channel ECG Connector
26Surface ECG ConnectionsThree cable–electrode configurations frequently used to generate surface ECGs include the following:• Patient to external recorder to PRM (Figure 12)• Patient to PRM to external recorder (Figure 13)• Simultaneous connections from patient to PRM and patient to external recorder (Figure 14)NOTE:  Annotated event markers cannot be sent to an external recorder.Also, suggested electrode locations on a patient are shown (Figure 15).
27Patient–Recorder–PRM ConnectionTo display a tracing on an external recorder and the PRM without using the patient ECG cable, set up equipment as shown in Figure 12.1. Connect the external recorder’s patient ECG leads to the appropriate electrodes.2. Route the surface ECG channel to the PRM using the ECG–BNC slave cable. (Use the Model 6930 or 6934 adapter cables, if necessary.)3. Connect the orange and green connectors of the external recorder cable to the external recorder for telemetered signals.4. Adjust gain and filters on the external recorder.5. Connect the telemetry wand and verify proper position. Make sure the wand cord does not cross other cables.Setup is now complete.Figure 12. External recorder gets surface signal and sends it to the PRM. PRM sends electrograms to the external recorder.PATIENT > RECORDER > PRMTelemetry WandPatient ECG CableExternal RecorderECG–BNC Slave CableExternal Recorder CablePRMConnectorsECG INWandINAnalogOUTSurface INSurface OUTChannels 2 and 3(orange and green)
28Patient–PRM–Recorder ConnectionTo display a tracing on the PRM and an external strip chart recorder using the patient ECG cables, set up equipment as shown in Figure 13.1. Connect the external recorder cable from the PRM to the external recorder input ports.• Channel 1 (red) for a surface trace• Channel 2 (orange) for telemetered signal 1• Channel 3 (green) for telemetered signal 22. Connect the patient ECG cable to the patient electrodes.3. Verify proper telemetry wand position.Setup is now complete.Figure 13. PRM receives surface signal via the patient cable and then sends surface and telemetered channels to the external strip chart recorder.Telemetry WandPatient ECG CableExternal RecorderExternal Recorder CablePATIENT > PRM > RECORDERChannel 1 (red)PRMConnectorsECGINWandINAnalogOUTSurface INChannels 2 and 3 (orange and green)
29Parallel ConnectionTo display traces on both PRM and ECG recorders using two different patient ECG leads, set up the equipment as shown in Figure 14.1. Connect the external recorder patient ECG leads to the appropriate limb electrodes.2. Connect the patient ECG cable to the patient electrode.3. Connect the external recorder cable from the PRM to the external recorder.NOTE:  This configuration will add the most noise to the tracings of the two PRM–recorder configurations.4. Adjust gain and filters on the external recorder.Setup is now complete.NOTE:  The right leg electrode conductor on the patient ECG cable is a driven ground. When connecting the PRM and an external ECG monitor in parallel, the driven grounds for the two instruments must be connected to the same patient limb (e.g., right leg electrode); otherwise, noise problems will occur.Figure 14. Parallel connection of PRM surface leads and external surface monitor.Telemetry WandPatient ECG CableExternal RecorderExternal Recorder CablePRMConnectorsECGINWandINAnalogOUTSurface INPatient ECG CablePATIENT > RECORDERPATIENT > PRMChannels 2 and 3 (orange and green)
30Suggested Electrode LocationsFigure 15 describes suggested locations for electrodes.Figure 15. Suggested electrode locations.Patient ECG Cable PATIENT > ECG CABLE > PRMApprox. area for C, V1–V6 (Brown)Telemetry WandECGINWandINPrimary LL (Red)Alternate LL (Red)Primary RL(Green)Alternate RL(Green)RA (White)LA (Black)KeyRA (Right Arm)LA (Left Arm)RL (Right Leg)LL (Left Leg)C (Chest)
31LABEL SYMBOLSTable 3 illustrates the symbols used on the Model 3120 PRM and includes an explanation of each symbol.Table 3. Label Symbols and Their MeaningsSymbol MeaningAlternating currentOn/Off buttonUSBParallel connector for printerVGA output for external monitorAnalog outputTelemetry wand inputIndicates defibrillator-proof CF-type patient ECG cable connectorPaper form feedCalibration pulseBring trace to baselineMark for nationally recognized testing for safety standards
32See instruction manualRadio, Telecommunications and Terminal Equipment (RTTE) symbol. Indicates that device does not operate in a harmonized bandwidthAttention (ECG and Telemetry connectors)Dangerous voltage. Refer servicing to GuidantIndicates the risk of electric shock; do not remove the cover (or back). Refer servicing to GuidantWaste, Electrical, and Electronic Equipment (WEEE) symbol. Indicates separate collection for electrical and electronic equipment (i.e., do not throw this device in the trash)ZIP telemetry indicator lightInductive telemetry indicator lightOn indicator lightVVoltageS/N Serial numberA/N Assembly numberThis side upTable 3. Label Symbols and Their MeaningsSymbol Meaning
33Fragile, handle with careKeep dryDo not use hooksTemperature limitationsHumidity limitationsAtmospheric pressure limitationsTable 3. Label Symbols and Their MeaningsSymbol Meaning
34SAFETY AND ELECTROMAGNETIC COMPATIBILITY COMPLIANCE STANDARDSThis equipment complies with the safety, electromagnetic compatibility (EMC), and medical safety requirements.Safety StandardsThis equipment has been tested and found to comply with applicable safety portions of the following standards: • EN 60601-1:1990 + A1:1993 + A2:1995• UL 60601-1:2003• CAN/CSA-C22.2 No. 601.1-M90Electromagnetic Compability StandardsThis equipment has been tested and found to comply with the applicable portions of the electromagnetic compatibility (EMC) standards:• FCC Part 15.209:2004 + 15.207:2004 + 15.249:2004• EN 300 330-2 V1.1.1:2000• EN 300 220-1 V1.3.1:2000• EN 301 489-1 V1.4.1:2002NOTES:  • Use special precautions regarding EMC during the installation and the use of the Model 3120 PRM, according to the EMC instructions given throughout this manual. Table 4 on page 36 and Table 5 on page 37 provide details about the PRM’s electromagnetic emissions and immunity.• Use caution when using RF portable and mobile equipment in close proximity to the Model 3120 PRM. Table 6 on page 38 and Table 7 on page 39 provide details about the PRM’s electromagnetic immunity.Medical Device DirectiveThis equipment has been tested and found to comply with the applicable limits for medical devices to IEC 60601-1-2:2001 [or EN 60601-1-2:2001 or Medical Device Directive 93/42/EEC]. This testing shows the device provides reasonable protection against harmful interference in a typical medical installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to other devices or is negatively impacted by other devices, the user is encouraged to try to correct the interference by one or more of the following measures:• Reorient or relocate the devices.• Increase the separation between the devices.• Connect the equipment to an outlet on a different circuit.• Consult the manufacturer or field service technician for help.These notes belong with the EMC section, not the MDD section.
35The PRM is capable of continuous operation and will not shut off automatically if it is unused for an extended time or if it runs out of paper. Keep the air intake and outlet free from obstruction.CAUTION:  The PRM is not water-proof or explosion-proof. It should not be used in the presence of flammable gas mixtures including anesthetic mixture with air, oxygen, or nitrous oxide.NOTES:  •Use special precautions regarding EMC during the installation and the use of the Model 3120 PRM, according to the EMC instructions given throughout this manual. Table 4 on page 36 and Table 5 on page 37 provide details about the PRM’s electromagnetic emissions and immunity.•Use caution when using RF portable and mobile equipment in close proximity to the Model 3120 PRM. Table 6 on page 38 and Table 7 on page 39 provide details about the PRM’s electromagnetic immunity.Federal Communications Commission (FCC)This device complies with Title 47, Part 15, of the FCC rules. Operation is subject to the following two conditions:1. This device may not cause harmful interference, and2. This device must accept any interference received, including interference that may cause undesired operation.CAUTION:  Changes or modifications not expressly approved by Guidant could void the user’s authority to operate the equipment.These sections moved to more appropriate locations.Changed to subhead that now falls under the Compliance Standards section
36ELECTROMAGNETIC EMISSIONS AND IMMUNITYTable 4.  Guidance and Manufacturer’s Declaration – Electromagnetic Emissions – for all Equipment and Systemsaa.  The Model 3120 PRM is intended for use in the electromagnetic environment specified above. The customer or the user of the Model 3120 PRM should assure that it is used in such an environment.Emissions test Compliance Electromagnetic environment – guidanceRF emissions (CISPR 11) Group 1The Model 3120 PRM uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment.RF emissions (CISPR 11) Class AThe Model 3120 PRM is suitable for use in all establishments other than domestic and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes.Harmonic emissions (IEC 61000-3-2) Class AVoltage fluctuations/flicker emissions (IEC 61000-3-3) Complies
37Table 5.  Guidance and Manufacturer’s Declaration – Electromagnetic Immunity – for all Equipment and Systemsaa.  The Model 3120 PRM is intended for use in the electromagnetic environment specified above. The customer or the user of the Model 3120 PRM should assure that it is used in such an environment.Immunity test IEC 60601test levelCompliance levelElectromagnetic environment – guidanceElectrostatic discharge (ESD) (IEC 61000-4-2)±6 kV contact±8 kV air±6 kV contact±8 kV airFloors should be wood, concrete, or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30 percent.Electrical fast transient/burst (IEC 61000-4-4)±2 kV for power-supply lines±1 kV for input/output lines±2 kV for power-supply lines±1 kV for input/output linesMains power quality should be that of a typical commercial or hospital environment.Surge (IEC 61000-4-5)±1 kV differential mode±2 kV common mode±1 kV differential mode±2 kV common modeMains power quality should be that of a typical commercial or hospital environment.Voltage dips, short interruptions, and voltage variations on power-supply input lines (IEC 61000-4-11)<5% UTb(>95% dip in UT) for 0.5 cycle 40% UT(60% dip in UT) for 5 cycles 70% UT(30% dip in UT) for 25 cycles <5% UT(>95% dip in UT) for 5 secb.  UT is the AC mains voltage prior to application of the test level.<5% UT(>95% dip in UT) for 0.5 cycle 40% UT(60% dip in UT) for 5 cycles 70% UT(30% dip in UT) for 25 cycles <5% UT(>95% dip in UT) for 5 secMains power quality should be that of a typical commercial or hospital environment. If the user of the Model 3120 PRM requires continued operation during power mains interruptions, it is recommended that the Model 3120 PRM be powered from an uninterruptible power supply or a battery.Power frequency (50/60 Hz) magnetic field (IEC 61000-4-8)3 A/m 3 A/mPower frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment.
38Table 6.  Guidance and Manufacturer’s Declaration – Electromagnetic Immunity – for Equipment and Systems That are not Life-Supportinga, b, ca.  The Model 3120 PRM is intended for use in the electromagnetic environment specified above. The customer or the user of the Model 3120 PRM should assure that it is used in such an environment.b.  At 80 MHz and 800 MHz, the higher frequency range applies.c.  These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects, and people.Immunity test IEC 60601test levelCompliance levelElectromagnetic environment – guidancePortable and mobile RF communications equipment should be used no closer to any part of the Model 3120 PRM, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.Recommended separation distanceConducted RF (IEC 61000-4-6)3Vrms150 kHz to 80 MHz 3VRadiated RF (IEC 61000-4-3)3V/m80 MHz to 2.5 GHz 3V/mwhere P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters (m).Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey,d should be less than the compliance level in each frequency range.eInterference may occur in the vicinity of equipment marked with the following symbol:d.  Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast, and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the Model 3120 PRM is used exceeds the applicable RF compliance level above, the Model 3120 PRM should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the Model 3120 PRM.e.  Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.d1.17 P=d1.17 P=(80MHz to 800MHz)d2.33 P=(800 MHz to 2.5 GHz)
39Table 7.  Recommended Separation Distances between Portable and Mobile RF Communications Equipment and the Model 3120 PRMa, b, c, da.  The Model 3120 PRM is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the Model 3120 PRM can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the Model 3120 PRM as recommended above, according to the maximum output power of the communications equipment.b.  For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.c.  At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.d.  These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects, and people.Rated maximum output power of transmitterWSeparation distance according to frequency of transmitterm150 kHz to 80 MHz80 MHz to 800 MHz800 MHz to 2.5 GHz0.01 0.12 0.12 0.230.1 0.370.370.741 1.171.172.3310 3.70 3.70 7.38100 11.70 11.70 23.33d1.17 P=d1.17 P=d2.33 P=
40SPECIFICATIONS (Nominal)Table 8. Nominal SpecificationsSafety classification Class I, Type CF, Defibrillation protectedDimensions 18.5 in (47 cm) deep, 14.5 in (36.8 cm) wide, 4.75 in (12.1 cm) highWeight (approximate) 21.5 lb (9.8 kg)Power rating 100–240 V, 50/60 Hz, 3.8/1.9 APower cord8 ft (2.4 m), 100–240 V. Reliable grounding is achieved only when equipment is connected to receptacle marked with “Hospital only” or “Hospital grade.”Operating temperature 50°F to 105°F (10°C to 35°C)Transport and storage temperature –40°F to 160°F (–40°C to 70°C)Operating, transport, and storage humidity 25% to 95%Atmospheric pressure 7.252 psi to 15.374 psi (50 kPa to 106 kPa)External printer support DB 25 parallel port connectorExternal monitor support DB 15 VGA port connectorAnalog output + 1 V output via seven-pin DIN connectorECG performance• Minimum amplitude detected 4.56 µV• Lead selection I, II, III, aVR, aVL, aVF, V• Intrinsic ventricular rate display 30 bpm to 240 bpm + 6 bpm• Input impedance > 2.5 M Ω• Electrode offset tolerance 300 mV• Storage resolution 800 samples/sec, 4.56 µV• Filter settings ON: 0.5 Hz to 25 Hz, + 0.2 dB; OFF: 0.05 Hz to 100 Hz, + 0.2 dB• Gain settings 1, 2, 5, 10, 20 mm/mV + 25%Wanded telemetry• Frequency Transmit: 69 kHzReceive: 0–100 kHz• Bandwidth 100 kHz• Modulation OOK• Effective radiated power –1.2 dBµV/mZIP telemetry
41• Frequency band ISM (902 to 928 MHz)• Bandwidth < 1 MHz• Modulation ASK/OOK• Effective radiated power –1.3 dBmInternal printer• Paper type Thermo-sensitive• Paper width 4 in (110 mm) • Chart speed 10, 25, 50, 100 mm/secBattery type DL 2450 or equivalentSafety features• Leakage current < 10 µA (patient); < 100 µA (chassis)• Defibrillator protection to 5,000 V, 400 J
42
Guidant Corporation 4100 Hamline Avenue NorthSt. Paul, MN 55112-5798  USATel: 651.582.4000 Fax: 651.582.4166Medical Professionals: 1.800.CARDIAC (227.3422) Toll FreePatients and Families: 1.866.GUIDANT  (484.3268) Toll Freewww.guidant.com© 2005 Guidant CorporationAll rights reserved.  357043-001  A  US  02/05FCC ID: ESCCRM312005*357043-001*

Navigation menu