Installation material and toolsThis section describes installation material such as cables, connectors and tools.Recommedations– Always use manufacturer specified installation products, materials and tools.– In general, use different cable ducts for the system network cables, audio cables andmains supply cables.– In public areas where people can touch or move above the connectors and cables, usemetal protection covers.!Warning!Do not exceed the bend limitations of system network cables (DCNM‑CBxxx):The minimum bend radius of the system network cable is 50 mm radius. System Network CableThe system network cables, terminated with connectors on both ends, are available indifferent lengths and are used to connect DICENTIS devices to each other. The cable consistsof four CAT‑5e twisted pairs to transmit data and two copper wires to supply the power.Ordering number Cable lengths m ftDCNM-CB02 2 6.56DCNM-CB05 5 16.40DCNM-CB10 10 32.81DCNM-CB25 25 82.02Table 5.1: Cable types and lengths Figure 5.1: DCNM-CBxx cable and connector view 5 5.126 en | Installation material and tools DICENTIS2016.07 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V.
System Cable ConnectorsThe connectors are used to make your own system network cables or to replace a connector.Two types of system cable connectors are available: DCNM-CBCON-I Installation CableConnectors, page 28 and DCNM-CBCON-N Network Cable Connectors, page 28.!Caution!Both connector types look similar but are different! So, only use the right type of connectorwith the right type of system cable. 1235798644315679812357986443156798Figure 5.2: DCNM-CBCON Front and exploded viewItem Description1 Strain relief boot2 Ferrule3 Plug connector shield4 Power contacts (Qty: 2)5 Load bar6 Power contact cavity (2 places)7 Housing8 Locking latch9 Signal contact cavity (8 Places)See also–System Network Cable, page 26–DCNM-CB250 System Installation Cable, page 30–DCNM-CBTK System Network Cable Toolkit, page 295.2 DICENTIS Installation material and tools | en 27Bosch Security Systems B.V. Hardware Installation Manual 2016.07 | V1.4 |
DCNM-CBCON-I Installation Cable ConnectorsThe DICENTIS 50 Installation Cable Connectors DCNM‑CBCON‑I can only be used with the theDCNM-CB250 System Installation Cable, page 30 by using the DCNM-CBTK System NetworkCable Toolkit, page 29.DCNM-CBCON-N Network Cable ConnectorsThe DICENTIS 50 Network Cable Connectors DCNM‑CBCON‑N can only be used with theSystem Network Cable, page 26 by using the DCNM-CBTK System Network Cable Toolkit, page29. 5.2.15.2.228 en | Installation material and tools DICENTIS2016.07 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V.
DCNM-CBTK System Network Cable ToolkitThe system network cable toolkit is used to connect the System Cable Connectors, page 27 tothe DCNM-CB250 System Installation Cable, page 30 or System Network Cable, page 26.21Item Description1 Power wiring tool.2 Signal wiring tool.Table 5.2: Toolkit contentNotice!Please consult the “custom length for system network cables” section on the DVD, which canbe downloaded at: https://licensing.boschsecurity.com/software 5.3 DICENTIS Installation material and tools | en 29Bosch Security Systems B.V. Hardware Installation Manual 2016.07 | V1.4 |
DCNM-CB250 System Installation CableThe system installation cable, without connectors, is available in a length of 250 meters and isused for making your own system network cable. Refer also to the sections System CableConnectors, page 27, DCNM-CBCON-I Installation Cable Connectors, page 28 and DCNM-CBTKSystem Network Cable Toolkit, page 29.Notice!The maximum system network cable length is: 100 m / 328,9 ft. Notice!Please consult the “custom length for system network cables” section on the DVD, which canbe downloaded at: https://licensing.boschsecurity.com/softwareSee also–System Cable Connectors, page 27 5.4  30 en | Installation material and tools DICENTIS2016.07 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V.
Mechanical installation of Central EquipmentAudio Powering Switch and Powering SwitchThe Audio Powering Switch is used:– to control system audio signals,– to route audio signals to/from devices,– to supply power to devices,– as an Ethernet switch to connect the PC and DICENTIS devices (DCNM-D / DCNM-DVT /DCNM-DSL / DCNM-DE / DCNM-MMD / DCNM-MMD2).The Powering Switch is used to:– supply power to devices.Scope of deliveryThe Audio Powering Switch and Powering Switch are shipped with the following parts:– 1x Mains power cord.– 1x Safety instructions.– 1x Set of 19 inch mounting brackets.– 4x bottom feet.– 1x DVD containing manuals and software (only with Audio Powering Switch). Front view1 2 2 13Figure 6.1: Audio Powering Switch / Powering SwitchItem Description1 19“ mounting brackets.2 Ventilation inlet.3Indication LED:Off: Switched off.Green: Switched on.Amber: Standby.Blinking: Services on the server PC are not running.Alternating green amber: When a software download is required. 66.1DICENTIS Mechanical installation of Central Equipment | en 31Bosch Security Systems B.V. Hardware Installation Manual 2016.07 | V1.4 |
Rear view10 12 13 15 17 1911 14 16 18 201 2 3 4 5 6 7 8 9Figure 6.2: Audio Powering Switch10 12 13 15 1714 16 1819209Figure 6.3: Powering Switch Item Description1, 5 XLR line outputs 1 and 2.2, 6 RCA line outputs 1 and 2.3, 7 XLR line inputs 1 and 2.4, 8 RCA line inputs 1 and 2.9 Mains inlet, mains switch and fuse holder.10 Reset button.11 Ground switch (grounded or floating).12 Socket 1 without power.13 Socket 2 low power.15, 17, 19 Socket 3, 4, 5 high power.14, 16, 18, 20 Overload LED for sockets 2‑5:Green: Power OK.Red: Overload. Remove cable and wait a few seconds for the system toreset the overload. 32 en | Mechanical installation of Central Equipment DICENTIS2016.07 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V.
How to install1. Install the Audio Powering Switch or Powering Switch in a 19 inch device rack system oron a flat surface. Two 19 inch mounting brackets and four bottom feet are supplied withthe Audio Powering Switch and Powering Switch. Refer to the following illustration.2. Connect all required cabling.3. Connect the mains supply.123Figure 6.4: 19 inch rack, flat surface and feet mountingItem Description1 19 inch rack mounting (bracket)2 Flat surface mounting (bracket)3 Feet mounting Notice!The unit extends 30 mm in front of the 19” mounting brackets when installed in a 19” racksystem. !Caution!Do not obstruct the airflow vents on the front side and rear left and right sides.   DICENTIS Mechanical installation of Central Equipment | en 33Bosch Security Systems B.V. Hardware Installation Manual 2016.07 | V1.4 |
Mechanical installation of Contribution DevicesDICENTIS devicesThe DICENTIS devices (DCNM-D, DCNM-DVT, DCNM-DSL, DCNM-DE, DCNM-MMD, DCNM-MMD2) are used to:– participate in a meeting or conference.– monitor and control a meeting or conference (chairperson use, depending on theconfiguration).DCNM-MMD / DCNM-MMD214578 691032Figure 7.1: Front, top, rear and side viewsItem Description1 7” capacitive touch screen.2 LED strip.3 Two‑way loudspeaker.4 3.5 mm stereo jack for headphone or headset with integrated microphone.5 Headphone volume control.6 Microphone request button.7 Chairperson priority or microphone mute button.8 Near Field Communication (NFC) reader (DCNM-MMD2 only).9 Cable guides.10 Microphone input connector. 77.134 en | Mechanical installation of Contribution Devices DICENTIS2016.07 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V.
DCNM-D / DCNM-DVT / DCNM-DSL / DCNM-DE Figure 7.2: Front, top, rear and side viewsItem Description1 Two‑way loudspeaker.2 Near Field Communication (NFC) reader.3 Chairperson priority button, microphone mute button, or microphone requestbutton for second participant.4 Microphone request button.5 Voting buttons.6 Language selection buttons.7 Language display.8 4.3” capacitive touch screen.9 3.5 mm stereo jack for headphone or headset with integrated microphone.10 Headphone volume control.11 Microphone input connector.12 Cable guides.  DICENTIS Mechanical installation of Contribution Devices | en 35Bosch Security Systems B.V. Hardware Installation Manual 2016.07 | V1.4 |
Connecting DICENTIS devicesThe DICENTIS Conference System can be quickly and easily configured as a daisy‑chainconfiguration or as a star configuration:–Daisy‑chain configuration: Uses dedicated cabling, consisting of CAT‑5e cables includingtwo additional power conductors (see Typical system setup, page 8).–Star configuration: Each DICENTIS device is connected with an individual standardCAT‑5e cable. An Ethernet switch is also required for providing Power over Ethernet(PoE).Notice!When Power over Ethernet is used, DICENTIS devices cannot be daisy‑chained. The star configuration makes use of connectors underneath the devices, ensuring for a neat,tidy system installation, especially advantageous for TV coverage.To connect the system network cables to the DICENTIS devices (refer to the following figure):1. Insert the system network cable/connector (2).2. Lead the system network cable through the cable guides (3). Installing DICENTIS devicesThe DICENTIS devices can be free-standing or fixed in more permanent installations usingmounting screws.1. The distance between the centres of the screw inserts (1) on the bottom is 100 mm.2. Use M4 type of screws with a device screw insert length of maximum 5 mm whenattaching the device to the bottom of the recess (1).3 4112Figure 7.3: Bottom view discussion DICENTIS devices (DCNM-MMD / DCNM-MMD2)  36 en | Mechanical installation of Contribution Devices DICENTIS2016.07 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V.
1 132Figure 7.4: Bottom view DICENTIS devices (DCNM-D / DCNM-DVT / DCNM-DSL / DCNM-DE)Item Description1 Screw insert for fixed installation.2 2x RJ45 connection input/output for system power cable.3 Cable guides.4 USB connector, for future use (DCNM-MMD / DCNM-MMD2 only). See also–System Network Cable, page 26–DCNM-CB250 System Installation Cable, page 30 DICENTIS Mechanical installation of Contribution Devices | en 37Bosch Security Systems B.V. Hardware Installation Manual 2016.07 | V1.4 |
DICENTIS MicrophonesBoth the DCNM‑HDMIC High Directive Microphone and DCNM-MICL/S Stem Microphone aretypically used with the DICENTIS devices.3647125826471258Figure 7.5: DCNM‑HDMIC and DCNM‑MICS / DCNM‑MICL front and bottom viewNumber Description1 LED indicator.2 Microphone grill.3 Adjustable stem (DCNM‑MICS / DCNM‑MICL).4 Connection guidance.5 Slider guidance.6 Connector plug.7 Lock-slider for lock release (Press and shift to release).8 Lock.9 Device female connector (see following figure). 7.238 en | Mechanical installation of Contribution Devices DICENTIS2016.07 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V.
How to connect or remove the microphoneThe microphone can be easily connected to the DICENTIS devices:964857Figure 7.6: DCNM‑HDMIC or DCNM-MICS / DCNM-MICL connection To do so:1. Gently guide the connection guidance (4) into the DICENTIS device microphoneconnector (9).2. Gently push the connector plug (6) into the device microphone connector (9) until theconnection lock (5) fits/click into place.3. To remove the microphone from the device: Shift lockslider (7) towards the device andhold in place lock release (8) and pull out the microphone.See also–DICENTIS devices, page 34 DICENTIS Mechanical installation of Contribution Devices | en 39Bosch Security Systems B.V. Hardware Installation Manual 2016.07 | V1.4 |
DCNM-MMDSP Anti-reflection foilThe DICENTIS anti‑reflection foil can be used to protect the tempered glass screen of aDICENTIS multimedia Device. Installation procedure1. Use the included alcohol swab and the microfiber fabric to clean the device LCD screenbefore installation.2. Peel the positioning adhesive release paper from the rear of anti‑reflection foil.3. Position the anti‑reflection foil on the device LCD screen, and then fix the positioningadhesive to the side of the device.4. Open the anti‑reflection foil, and use the “cleaning stick” to clean surface dust from theLCD screen.5. Peel the protective film from the other side of the anti‑reflection foil.6. Lightly press the anti‑reflection foil on to the LCD screen. If air bubbles are trapped underthe anti‑reflection foil, use the “squeegee” to remove them.DCNM-NCH Name Card HolderThe name card holder (1) can be used to permanently display the participant’s name on therear of a DICENTIS multimedia Device. The name card holder has two magnets (2) that allow itto be easily attached to, and removed from, the rear of the device.122Figure 7.7: DCNM‑NCH assemblyItem Description1 Name card holder.2 Magnets. Notice!A paper insert template is included on the DVD that can be downloaded at: https://licensing.boschsecurity.com/software 7.37.4 40 en | Mechanical installation of Contribution Devices DICENTIS2016.07 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V.
Installation TestAn installation test is needed to prevent connection mismatches and find potential productdefects at an early stage. Not to do so could result in a system malfunctioning.Each DICENTIS device has its own built‑in diagnostics, which can be used for faultfinding. Thediagnostics starts as soon the DICENTIS device is powered on. The DICENTIS ConferenceSystem does not have to be configured with, and connected to, the system controller PC.Preconditions1. All system network cables are connected to the devices.2. The Audio Powering Switch and Powering Switch(es) are installed.Start the testPower on the Audio Powering Switches and Powering Switches used in the system: Eachconnected device powers on and initializes.   1. After the DICENTIS multimedia Device and the DICENTIS discussion Extended haveinitialized, the diagnostic screen is shown.2. If the text “Link down” is shown:– The network cable is not connected or defective.– The device is only connected with one system network cable (“Link down” is shownon the side where the device is not connected).3. If the system network cable is correctly connected to the network, the network speed isshown.4. If the DICENTIS multimedia Device and the DICENTIS discussion Extended are connectedto an Audio Powering Switch, Powering Switch or another multimedia device, and 100 Mbis shown:– Not all wiring inside the system network cable connector is correctly connected orbroken. You need to check the wiring and connector.– If the cable is connected to a 100 Mb switch, it is correct.5. Click the info button to see additional information of the multimedia device.6. When everything is correctly connected, and the device does not have the applicationsoftware, it shows the text “Please download software”.7. Now the device can be downloaded:8DICENTIS Installation Test | en 41Bosch Security Systems B.V. Hardware Installation Manual 2016.07 | V1.4 |
– Downloading devices is not covered in this manual. Refer to the DICENTISconfiguration manual on how to download the devices. Customer serviceIf a fault cannot be resolved, please contact your supplier or system integrator, or go directlyto your Bosch representative.42 en | Installation Test DICENTIS2016.07 | V1.4 | Hardware Installation Manual Bosch Security Systems B.V.
  Bosch Security Systems B.V.Torenallee 495617 BA EindhovenNetherlandswww.boschsecurity.com© Bosch Security Systems B.V., 2016