Bosch Security Systems DCNM-IDESKX DCNM-IDESK, DCNM-IDESKVID User Manual DCN HW en part 2

Bosch Security Systems BV DCNM-IDESK, DCNM-IDESKVID DCN HW en part 2

Contents

DCN_HW_en part 2

DICENTIS Installation material and tools | en 37Bosch Security Systems B.V. Hardware Installation Manual 2018.09 | V1.8 |DCNM-CB02-IDCNM-CB02-IDCNM-(A)PSCAT-5E cableDCNM-CB02-IDCNM-CB02-ICable coupler used as interface
38 en | Installation material and tools DICENTIS2018.09 | V1.8 | Hardware Installation Manual Bosch Security Systems B.V.Figure5.3: Creating a tension relief, tie wrap prevents the power cables from being pulled out accidentally.5.5.4 Using a cable coupler to insert power locallyThe cable coupler can be used to insert a local power supply, enabling you to place a third-party 48VDC power close to the participant devices.To set this up:1. Open the housing of the cable coupler.2. Connect the power cables to the screw terminals + and -.3. Remove the break-out of the housing to guide the power cables through.4. Create a tension release.!Warning!Risk of electric shock. Exposed power cables are a potential hazard. Make sure all powercables are securely fastened by fixing them with a tie wrap on the inside of the box (seedrawing ‘Creating a tension relief’).5. Close the housing and fix the screw with torque 0.4Nm.Note:– Requirements for the power supply:– nominal output of 48VDC (ranging from 47-49VDC)– the ripple should be less than 200 mV pk-pk– maximum output current should not exceed 3.0A (or limited to 3.0A, becauseDICENTIS cables and devices have a maximum rating for this current)– Advice– It is strongly advised that the power supply has its own short circuit protection witha short circuit output current ranging from 4.3 to 5.0A.– When the power supply has an automatic restart after a short circuit, this restartfunction should have an interval time of 3 to 4 seconds and should have no morethan 4 restart attempts.– Upon powering off the power supply, the output should be less than 9V, 1mA.– The maximum distance between the (A)PS and the conference device is limited to 100mdue to the Ethernet properties.
DICENTIS Installation material and tools | en 39Bosch Security Systems B.V. Hardware Installation Manual 2018.09 | V1.8 |DCNM-(A)PSCAT-5E cableDCNM-CB02-I  48 VDC, 3Apower supplyCAT-5E cableDCNM-CB02-I  48 VDC, 3Apower supplyTransporting the power via cableFigure5.4: Creating a tension relief, tie wrap prevents the power cables from being pulled out accidentally.
40 en | Mechanical installation of Central Equipment DICENTIS2018.09 | V1.8 | Hardware Installation Manual Bosch Security Systems B.V.6 Mechanical installation of Central Equipment6.1 Audio processor and powering switch and Powering switchThe Audio processor and powering switch is used:– to control system audio signals,– to route audio signals to/from devices,– to supply power to devices,– as an Ethernet switch to connect the PC and DICENTIS devices (DCNM-D / DCNM-DVT /DCNM-DSL / DCNM-DE / DCNM-MMD / DCNM-MMD2).The Powering switch is used to:– supply power to devices.Scope of deliveryThe Audio processor and powering switch and Powering switch are shipped with the followingparts:– 1x Mains power cord.– 1x Safety instructions.– 1x Set of 19 inch mounting brackets.– 4x bottom feet.– 1x DVD containing manuals and software (only with Audio processor and poweringswitch).Front view1 2 2 13Figure6.1: Audio processor and powering switch / Powering switchItem Description1 19“ mounting brackets.2 Ventilation inlet.3Indication LED:Off: Switched off.Green: Switched on.Amber: Standby.Blinking: Services on the server PC are not running.Alternating green amber: When a software download is required.
DICENTIS Mechanical installation of Central Equipment | en 41Bosch Security Systems B.V. Hardware Installation Manual 2018.09 | V1.8 |Rear view10 12 13 15 17 1911 14 16 18 201 2 3 4 5 6 7 8 9Figure6.2: Audio processor and powering switch10 12 13 15 1714 16 1819209Figure6.3: Powering switchItem Description1, 5 XLR line outputs 1 and 2.2, 6 RCA line outputs 1 and 2.3, 7 XLR line inputs 1 and 2.4, 8 RCA line inputs 1 and 2.9 Mains inlet, mains switch and fuse holder.10 Reset button.11 Ground switch (grounded or floating).12 Socket 1 without power.13 Socket 2 low power.15, 17, 19 Socket 3, 4, 5 high power.14, 16, 18, 20 Overload LED for sockets 2‑5:Green: Power OK.Red: Overload. Remove cable and wait a few seconds for the system toreset the overload.
42 en | Mechanical installation of Central Equipment DICENTIS2018.09 | V1.8 | Hardware Installation Manual Bosch Security Systems B.V.How to install1. Install the Audio processor and powering switch or Powering switch in a 19 inch devicerack system or on a flat surface. Two 19 inch mounting brackets and four bottom feet aresupplied with the Audio processor and powering switch and Powering switch. Refer tothe following illustration.2. Connect all required cabling.3. Connect the mains supply.123Figure6.4: 19 inch rack, flat surface and feet mountingItem Description1 19 inch rack mounting (bracket)2 Flat surface mounting (bracket)3 Feet mountingNotice!The unit extends 30mm in front of the 19” mounting brackets when installed in a 19” racksystem.!Caution!Do not obstruct the airflow vents on the front side and rear left and right sides.
DICENTIS Mechanical installation of Contribution Devices | en 43Bosch Security Systems B.V. Hardware Installation Manual 2018.09 | V1.8 |7 Mechanical installation of Contribution Devices7.1 DICENTIS devicesThe DICENTIS devices (DCNM-D, DCNM-DVT, DCNM-DSL, DCNM-DE, DCNM-MMD, DCNM-MMD2) are used to:– participate in a meeting or conference.– monitor and control a meeting or conference (chairperson use, depending on theconfiguration).DCNM-MMD / DCNM-MMD214578 691032Figure7.1: Front, top, rear and side viewsItem Description1 7” capacitive touch screen.2 LED strip.3 Two‑way loudspeaker.4 3.5 mm stereo jack for headphone or headset with integrated microphone.5 Headphone volume control.6 Microphone request button.7 Chairperson priority or microphone mute button.8 Near Field Communication (NFC) reader (DCNM-MMD2 only).9 Cable guides.10 Microphone input connector.– DCNM-MMD2 is compliant with the Radio Equipment Directive (RED) 2014/53/EU.– Operating frequency is 13.56 MHz. Maximum field strength is 8.05 dBµA/m @ 3m.!Warning!This equipment is compliant with Class A of CISPR 32. In a residential environment thisequipment may cause radio interference. This equipment is intended for environment Class A.
44 en | Mechanical installation of Contribution Devices DICENTIS2018.09 | V1.8 | Hardware Installation Manual Bosch Security Systems B.V.DCNM-D / DCNM-DVT / DCNM-DSL / DCNM-DEFigure7.2: Front, top, rear and side viewsItem Description1 Two‑way loudspeaker.2 Near Field Communication (NFC) reader.3 Chairperson priority button, microphone mute button, or microphone requestbutton for second participant.4 Microphone request button.5 Voting buttons.6 Language selection buttons.7 Language display.8 4.3” capacitive touch screen.9 3.5 mm stereo jack for headphone or headset with integrated microphone.10 Headphone volume control.11 Microphone input connector.12 Cable guides.– DCNM-DE, DCNM-DVT and DCNM-DSL are compliant with the Radio Equipment Directive(RED) 2014/53/EU.– Operating frequency is 13.56 MHz. Maximum field strength is -8.4 dBµA/m @ 10m.
DICENTIS Mechanical installation of Contribution Devices | en 45Bosch Security Systems B.V. Hardware Installation Manual 2018.09 | V1.8 |Connecting DICENTIS devicesThe DICENTIS Conference System can be quickly and easily configured as a daisy‑chainconfiguration or as a star configuration:–Daisy‑chain configuration: Uses dedicated cabling, consisting of CAT‑5e cables includingtwo additional power conductors (see Typical system setup, page 10).–Star configuration: Each DICENTIS device is connected with an individual standardCAT‑5e cable. An Ethernet switch is also required for providing Power over Ethernet(PoE).Notice!When Power over Ethernet is used, DICENTIS devices cannot be daisy‑chained. Please useunshielded cable for the DICENTIS discussion devices.The star configuration makes use of connectors underneath the devices, ensuring for a neat,tidy system installation, especially advantageous for TV coverage.To connect the system network cables to the DICENTIS devices (refer to the following figure):1. Insert the system network cable/connector (2).2. Lead the system network cable through the cable guides (3).Installing DICENTIS devicesThe DICENTIS devices can be free-standing or fixed in more permanent installations usingmounting screws.1. The distance between the centres of the screw inserts (1) on the bottom is 100mm.2. Use M4 type of screws with a device screw insert length of maximum 5mm whenattaching the device to the bottom of the recess (1).3 4112Figure7.3: Bottom view discussion DICENTIS devices (DCNM-MMD / DCNM-MMD2)
46 en | Mechanical installation of Contribution Devices DICENTIS2018.09 | V1.8 | Hardware Installation Manual Bosch Security Systems B.V.1 132Figure7.4: Bottom view DICENTIS devices (DCNM-D / DCNM-DVT / DCNM-DSL / DCNM-DE)Item Description1 Screw insert for fixed installation.2 2x RJ45 connection input/output for system power cable.3 Cable guides.4 USB connector, for future use (DCNM-MMD / DCNM-MMD2 only).See also– DICENTIS System Cable Assemblies, page 31– DCNM-CB250-I System Installation Cable, page 347.2 DCNMM-IDESK / DCNM-IDESKVID Interpreter deskThe Interpreter desks (DCNM-IDESK and DCNM-IDESKVID) are used to:– interpret the floor language (channel A) in a meeting or conference,– relay the interpretation to various target languages via channel selection (channel B or C).123456 710118912 13b BItem Description1Loudspeaker volume knob - Adjusts the volume level of the signal that is sent tothe loudspeaker of the interpreter desk.2Treble knob - Adjusts the level of the treble of the signal that is sent to theheadphones.3Bass knob - Adjusts the level of the bass of the signal that is sent to theheadphones.
DICENTIS Mechanical installation of Contribution Devices | en 47Bosch Security Systems B.V. Hardware Installation Manual 2018.09 | V1.8 |Item Description4Headphones volume knob - Adjusts the volume level of the signal that is sent tothe headphones.5Menu knob -Rotary control with integrated push button to configure and operatethe interpreter desk.6Pre-select buttons - Allows the interpreters to select a channel from which theycan render an interpretation (input).7Output buttons - Sets the output the target language will be sent to (A, B, C).8b - B buttons - Press these 2 buttons (with a small raised dash) at the same timeto enter the installation mode and assign the device to a booth and desk. See“DICENTIS Software manual”, chapter 9 on how to configure the interpreterdesk.9Assignable buttons - 3 buttons that can be freely assigned10 Display - Shows the configuration, user menus and provides user feedback.11 Floor/Auto-relay button - Sets the source of the interpretation.12 Microphone button - Enables or disables the microphone. The microphonebutton has a red LED that comes on when the microphone is enabled (on-air). Agreen LED shows that the booth is not in use.13 Mute button - Temporarily disables the microphone.Connecting Interpreter desksTwo RJ45 compatible connections for system communication and power are available forquick and easy connection of the interpreter desks. Loop-through cabling can be applied byusing DICENTIS System cables or star cabling using standard CAT-5e cables and PoE switches.Installing Interpreter desksThe interpreter desks can be installed free-standing or fixed in more permanent installations(table-top) using mounting screws.!Warning!The screws must be M3 and should not be screwed in deeper than 5 mm (0.2 inches) to avoiddamaging the device.112 34Figure7.5: DCNM-IDESK / DCNM-IDESKVID bottom view
48 en | Mechanical installation of Contribution Devices DICENTIS2018.09 | V1.8 | Hardware Installation Manual Bosch Security Systems B.V.Item Description1 Screw insert for fixed installation2 2 x RJ45 connection input/output for system power cable3 HDMI video output (DCNM-IDESKVID only)4 USB connector for the DCNM-IDESKINT On-air & telephone interface DCNM-IDESK. Refer to section 7.6
DICENTIS Mechanical installation of Contribution Devices | en 49Bosch Security Systems B.V. Hardware Installation Manual 2018.09 | V1.8 |7.3 DICENTIS MicrophonesBoth the DCNM‑HDMIC High Directive Microphone and DCNM-MICL/S Stem Microphone aretypically used with the DICENTIS devices.3647125826471258Figure7.6: DCNM‑HDMIC and DCNM‑MICS/DCNM‑MICL front and bottom viewNumber Description1 LED indicator.2 Microphone grill.3 Adjustable stem (DCNM‑MICS/DCNM‑MICL).4 Connection guidance.5 Slider guidance.6 Connector plug.7 Lock-slider for lock release (Press and shift to release).8 Lock.9 Device female connector (see following figure).How to connect or remove the microphoneThe microphone can be easily connected to the DICENTIS devices:
50 en | Mechanical installation of Contribution Devices DICENTIS2018.09 | V1.8 | Hardware Installation Manual Bosch Security Systems B.V.964857Figure7.7: DCNM‑HDMIC or DCNM-MICS/DCNM-MICL connectionTo do so:1. Gently guide the connection guidance (4) into the DICENTIS device microphoneconnector (9).2. Gently push the connector plug (6) into the device microphone connector (9) until theconnection lock (5) fits/click into place.3. To remove the microphone from the device: Shift lockslider (7) towards the device andhold in place lock release (8) and pull out the microphone.See also– DICENTIS devices, page 43
DICENTIS Mechanical installation of Contribution Devices | en 51Bosch Security Systems B.V. Hardware Installation Manual 2018.09 | V1.8 |7.4 DCNM-MMDSP Anti-reflection foilThe DICENTIS anti‑reflection foil can be used to protect the tempered glass screen of aDICENTIS multimedia Device.Installation procedure1. Use the included alcohol swab and the microfiber fabric to clean the device LCD screenbefore installation.2. Peel the positioning adhesive release paper from the rear of anti‑reflection foil.3. Position the anti‑reflection foil on the device LCD screen, and then fix the positioningadhesive to the side of the device.4. Open the anti‑reflection foil, and use the “cleaning stick” to clean surface dust from theLCD screen.5. Peel the protective film from the other side of the anti‑reflection foil.6. Lightly press the anti‑reflection foil on to the LCD screen. If air bubbles are trapped underthe anti‑reflection foil, use the “squeegee” to remove them.7.5 DCNM-NCH Name Card HolderThe name card holder (1) can be used to permanently display the participant’s name on therear of a DICENTIS multimedia Device. The name card holder has two magnets (2) that allow itto be easily attached to, and removed from, the rear of the device.122Figure7.8: DCNM‑NCH assemblyItem Description1 Name card holder.2 Magnets.Notice!A paper insert template is included on the DVD that can be downloaded at: https://licensing.boschsecurity.com/software
52 en | Mechanical installation of Contribution Devices DICENTIS2018.09 | V1.8 | Hardware Installation Manual Bosch Security Systems B.V.7.6 DCNM-IDESKINT On-air & telephone interface DCNM-IDESKThis interface is used to control a booth on-air light and to show a telephone ringing indicator.The interface is connected to the USB port of one of the DCNM-IDESK devices inside thebooth.The USB cable must be purchased separately.
DICENTIS Installation Test | en 53Bosch Security Systems B.V. Hardware Installation Manual 2018.09 | V1.8 |8 Installation TestAn installation test is needed to prevent connection mismatches and find potential productdefects at an early stage. Not to do so could result in a system malfunctioning.Each DICENTIS device has its own built‑in diagnostics, which can be used for faultfinding. Thediagnostics starts as soon the DICENTIS device is powered on. The DICENTIS ConferenceSystem does not have to be configured with, and connected to, the system controller PC.Preconditions1. All system network cables are connected to the devices.2. The Audio processor and powering switch and Powering switch(es) are installed.Start the testPower on the Audio processor and powering switches and Powering switches used in thesystem: Each connected device powers on and initializes.1. After the DICENTIS multimedia Device / the DICENTIS discussion Extended haveinitialized, the diagnostic screen is shown.2. If the text “Link down” is shown:– The network cable is not connected or defective.– The device is only connected with one system network cable (“Link down” is shownon the side where the device is not connected).3. If the system network cable is correctly connected to the network, the network speed isshown.4. If the DICENTIS multimedia Device / the DICENTIS discussion Extended are connected toan Audio processor and powering switch, Powering switch or another multimedia device,and 100Mb is shown:– Not all wiring inside the system network cable connector is correctly connected orbroken. You need to check the wiring and connector.– If the cable is connected to a 100Mb switch, it is correct.5. Click the info button to see additional information of the multimedia device.6. When everything is correctly connected, and the device does not have the applicationsoftware, it shows the text “Please download software”.7. Now the device can be downloaded:
54 en | Installation Test DICENTIS2018.09 | V1.8 | Hardware Installation Manual Bosch Security Systems B.V.– Downloading devices is not covered in this manual. Refer to the DICENTISconfiguration manual on how to download the devices.Customer serviceIf a fault cannot be resolved, please contact your supplier or system integrator, or go directlyto your Bosch representative.
Bosch Security Systems B.V.Torenallee 495617 BA EindhovenNetherlandswww.boschsecurity.com© Bosch Security Systems B.V., 2018

Navigation menu