Bosch Security Systems CRS-NC-IS76 IS76 Person Detection System User Manual Installation Manual

Bosch Security Systems GMBH IS76 Person Detection System Installation Manual

Installation Manual

  __________________________________________________________________________________________________________________ Edition: July 2009 Document N°: 953-26b    Page 1 of 10               IS76 Beacon with Ferrite Antenna  Installation Manual
  __________________________________________________________________________________________________________________ Edition: September 2011 Document N°: 953-26b    Page 2 of 10  Document No 953.26b  IS76 Beacon with Ferrite Antenna: Installation Manual Edition: September 2011 Editor: TeleAlarm SA All rights reserved.  TeleAlarm SA reserves the right to make changes to the information contained in this document at any time without prior notice. Great care has been given to the contents of this document; however TeleAlarm SA cannot be held liable for the consequences of any errors or omissions contained herein or for consequential or incidental damages incurred as a result of acting on information contained in the document.  TeleAlarm SA Bosch Group Administration, R&D and Aftersale Rue du Pont 23 CH-2300 la Chaux-de-Fonds Switzerland Phone +41 (0)32 911 11 11 Fax  +41 (0)32 911 11 00 www.telealarm.com  Bosch Sicherheitssysteme GmbH Haus-ServiceRuf Ingersheimer Straße 16 D-70499 Stuttgart Germany Phone 0711 3653 1000 Fax  0711 811 5125 294 Haus-Service.Ruf@de.bosch.com www.bosch-sicherheitsprodukte.de Bosch Security Systems Ltd Broadwater Park North Orbital Road Denham UB9 5HN United Kingdom Phone 01895-878088 Fax 01895-878089 uk.securitysystems@bosch.com www.boschsecurity.co.uk Bosch Security Systems France Atlantic 361 361, avenue du Général de Gaulle F-92147 Clamart France Phone + 33 (0)825 12 8000  (0,15 € TTC/Min) Fax  + 33 (0)820 900 960  (0,12 € TTC/Min) fr.securitysystems@bosch.com www.boschsecurity.fr Bosch Security Systems BV Postbus 80002 NL-5600 JB Eindhoven Netherlands Phone  +31 40 25 77 200 Fax  +31 40 25 77 202 nl.securitysystems@bosch.com www.boschsecurity.nl Bosch Security Systems nv/sa Torkonjestraat 21F B-8510 Marke Belgium Phone +32 (0)56 20 02 40 Fax  +32 (0)56 20 26 75 be.securitysystems@bosch.com www.boschsecurity.be Bosch Security Systems AB Vestagatan 2 SE-416 64 Göteborg Sweden Phone  +46 (0)31 722 5300 Fax  +46 (0)31 722 5340 se.securitysystems@bosch.com www.boschsecurity.se
  __________________________________________________________________________________________________________________ Edition: July 2009 Document N°: 953-26b    Page 3 of 10   Content  Locator Function .............................................................................................................. 4 IS76 Beacon with Ferrite Antenna .................................................................................... 4 IS76 Ferrite Antenna .................................................................................................... 4 IS76 Ferrite Beacon Controller...................................................................................... 5 System Supervision...................................................................................................... 5 Features of the IS76 Beacon System ............................................................................... 5 IS76 Ferrite Antenna........................................................................................................ 6 IS76 Beacon Controller .................................................................................................... 6 Connection Compartment ................................................................................................ 7 Enable Locator Function in NurseCall System .................................................................. 7 Configuration and Wiring.................................................................................................. 8 Ferrite Beacon Antenna ................................................................................................... 9 Ferrite Beacon Controller ................................................................................................. 9
  __________________________________________________________________________________________________________________ Edition: September 2011 Document N°: 953-26b    Page 4 of 10  Locator Function The NurseCall system can be set to handle a Locator function. For this purpose, beacon modules and antennas of type IS75 or IS76 need to be installed on doors or corridors in the building you want to supervise. When passing one of these modules the Wristband Transmit-ters of type S37L or the Pendant Transmitters of type S35L refresh the position information that is stored into them. When triggering an Alarm, the transmitters S37L and S35L do not only transmit the identification (who sent the alarm), but also the position of the last passed module (where has the alarm been triggered).  At the arrival of a call, the information of the actual position is indicated additionally on the NurseCall units. This information can be made visible by pressing the yellow button on the NurseCall Main- or Relay Unit.   “Locator” information block:      255 positions (POS: 000 - 254) can be differentiated. When passing beacon modules with position numbers 231 - 254 the transmitters S37L and S35L can send a call for help auto-matically without manual activation (wandering). Fixed transmitters that do not handle a   Locator function (N46) are always indicated with the position 000.  IS76 Beacon with Ferrite Antenna  The IS76 Beacon system consists of two elements:   The IS76 Ferrite Antenna  The IS76 Ferrite Beacon Controller IS76 Ferrite Antenna   The IS76 Ferrite antenna has to be mounted on the place that has to be identified with a  location beacon code. The antenna is well suited to be mounted in a vertical position on (or next to) a door frame. In some circumstances it may also be mounted horizontally. The IS76 Ferrite Antenna can be placed outdoors as well as indoors.   HELP                          A03  POS: 077
  __________________________________________________________________________________________________________________ Edition: July 2009 Document N°: 953-26b    Page 5 of 10   IS76 Ferrite Beacon Controller  The IS76 Ferrite Beacon Controller is necessary to drive the IS76 Ferrite Antenna. It con-nects to the mains power via an external power supply. Up to two IS76 Ferrite Antennas may be connected to the IS76 Beacon Controller, depending on the size of the passage that has to be covered with the beacon. The beacon location code is set-up on the IS76 Ferrite     Beacon Controller. Contrary to the ferrite antenna, the IS76 Ferrite Beacon Controller has to be mounted indoors, in a well ventilated cool place.  Connection compartment SupervisionSignal lamp(LED):  Figure 1 System Supervision  The operation of the IS76 Beacon system is supervised. An eventual operation failure     (broken wire or overload) is indicated by the front panel LED and by the opening of a       "normally closed" relay contact that is accessible from the terminal block. The supervision output may be connected to an RAC-type alarm transmitter which would transmit the beacon operation failure to the NurseCall System.   Features of the IS76 Beacon System   Ferrite antenna offers a better defined capture range that is less dependent on the      surrounding building material  The antenna may be installed in or outdoors  Up to 230 user selectable position (location) codes (001 to 230)  Up to 24 user selectable "Wandering" codes (231 to 254)  Supervision of the beacon functionality
  __________________________________________________________________________________________________________________ Edition: September 2011 Document N°: 953-26b    Page 6 of 10  IS76 Ferrite Antenna  The Antenna is best fitted to be mounted vertically on a door's frame. In any case, the middle of the antenna should be at a height of 1 meter from the floor. The antenna has to be fixed by two screws, according to the figure below.            Figure 2  Remove the cover caps at both ends of the antenna by sliding them against the outside  Secure the antenna against the wall with both screws  Replace the cover caps by sliding them over the housing  Note: Even if the functionality of the Ferrite Beacon System is not affected by the presence of metallic items, it is not recommended to fix the antenna directly against such items. In order to avoid overheating of the IS76 Beacon Controller, install the antenna at least 1.5 cm away from metallic frames or surfaces.   IS76 Beacon Controller  The IS76 Beacon Controller can be fixed with two to five screws on the wall. Two holes at 60 mm interval are provided for direct mounting on connection boxes. The three upper holes are used for positioning the device and cannot be reached from the Connection Compartment. Two of the lower holes can be reached from outside and thus used for fixing the device.  FCC Statement  Note: This device complies with Part 15 of the FCC Rules [and with RSS-210 of Industry Canada]. Operation is subject to the following two conditions: (1)  this device may not cause harmful interference, and  (2)  this device must accept any interference received, including interference that may cause undesired operation.  Note: Changes or modifications made to this equipment not expressly approved by (manufacturer name) may void the FCC authorization to operate this equipment. 30mm +/- 1mm  540mm +/- 1mm       2 X D 5.5mm 600mm 0/-10mm
  __________________________________________________________________________________________________________________ Edition: July 2009 Document N°: 953-26b    Page 7 of 10  53.88013113.1Ø7.559.918.13.72263.716276.6 Figure 3 Important Note:  In order to ensure proper cooling of the Beacon Controller, the unit needs to be in-stalled vertically in a well ventilated place (avoid to mount it in sealed boxes).  Connection Compartment  All of the wiring and configuration functions such as:   Connection of the IS76 Ferrite Antenna(s)   Connection of the wired supervision output  Setting of the Location identification code  Can be carried out in the connection compartment. It is reached by taking off the lower part of the housing (see). This can be done even if the device is fixed on the wall.  The connection cables can be channelled towards the outside through the hole next to the terminal blocks or downwards by breaking off part of the rear housing.  Connection of the power supply can be done without taking off the lower part of the housing. Enable Locator Function in NurseCall System  In order to be operational, the Locator function has to be enabled in the NurseCall Main Unit (refer to section "Selection Locate Function YES or No" in the NurseCall User Manual)
  __________________________________________________________________________________________________________________ Edition: September 2011 Document N°: 953-26b    Page 8 of 10  Configuration and Wiring ON++++++++12864321684211x1281x641x321x161x80x40x22480x1++++++=+Position number:Supervision Signal Lamp:Green: okRed: operation failure Ferrite Beacon Antenna AFerrite Beacon Antenna B*Supervision OutputPower Supply 24 VDCSupervision ofBeacon A:Supervision ofBeacon B:EnabledDisabled  *Antenna B is optionalIt is used to extend thecapture range on large(double) doorsRAC(optional) Blue*Blue*White*White**Polarity ofthe antennaand the wiring has tobe respectedwhen twoantennas areused for thesame beaconlocation  AB*Example above:
  __________________________________________________________________________________________________________________ Edition: July 2009 Document N°: 953-26b    Page 9 of 10   Ferrite Beacon Antenna  Housing Plastic case ASA for wall mounting  L x H x P  600 x 30 x 30 mm  Weight  about 700 g   Connecting cable     2 m "twisted pair"   (may be extended up to 10 m)   Operation Range1 typ. 2.6 m typ. 3.6 m Antenna1 When used in conjunction with S37L Wristband Transmitters of REV B and higher.   Ferrite Beacon Controller  Housing Plastic case ASA  For wall mounting (L x H x P)    133 x 82 x 26 mm Weight      about 200 g  AC Power supply (included)    100 – 240 VAC   DC Power supply    22 - 24 VDC / max. 400 mA (1 antenna)           Max. 800 mA (2 antennas)  Frequency    68 kHz  Supervision Output Relay Max. Switching power    125 VA  / 60 W Max. Switching voltage    40 V DC Max. switching current    2 A      Technical data is subject to changes.
  __________________________________________________________________________________________________________________ Edition: September 2011 Document N°: 953-26b    Page 10 of 10   FCC Statement for Class B digital device  Note: This equipment has been tested and found to comply with the limits for a Class B digital de-vice, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equip-ment does cause harmful interference to radio or television reception, which can be deter-mined by turning the equipment off and on, the user is encouraged to try to correct the inter-ference by one or more of the following measures: •  Reorient or relocate the receiving antenna. •  Increase the separation between the equipment and receiver. •  Connect the equipment into an outlet on a circuit different from that to which the re-ceiver is connected. •  Consult the dealer or an experienced radio/TV technician for help.

Navigation menu