=3 | Bracket mount (optional)Changes or modifi cations not expressly approved by Bosch Security Systems, Inc. can void the user’s authority to operate the equipment.UL/C-ULUse only a Listed Class 2 limited-power source.Standby power: The Listed control unit or a Listed burglary power supply must provide 4 hours of standby power.Install the unit in accordance with National Electrical Code NFPA 70 and Part 1 of the Canadian Electrical code CSA C22.1.Models ISC-CDL1-W15H & ISC-CDL1-W15K are not UL or C-UL Listed.12B328B338B335FCCThis device complies with part 15 of the FCC Rules. and  Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d’un type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité nécessaire à l’établissement d’une communication satisfaisante.This product is intended for use in the following countries within the European Union and in other countries outside the European Union:ISC-CDL1-W15G (10.525 GHz):   Austria, Belgium, Denmark, Finland, Greece, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden.ISC-CDL1-W15H (10.588 GHz):  France, United KingdomISC-CDL1-W15K (9.35 GHz):  Germany2 |  Surface mount1 |  Unlock and open2,3m - 2,75 m(7.5 ft - 9 ft)Test yearlyOptional Brackets: B328, B338, B335A mounting bracket can reduce the detector’s range and create dead zones. Not investigated by UL. Not EN50131 compliant. La certifi cazione IMQ decade nel caso di installazione del rilevatore con gli snodi opzionali.
Bosch Security Systems, Inc. F.01U.304.624 | 03 | 2015.01 | 27b | Double EOL resistors7a |  Single EOL resistor7 | Wiring 6 | Leveling5 |  Wire knock-out options12122.2 k1.0 k2.2 k33 k1.0 kNC    NCT      T       NC NC TT129 to 15 VDCTT2NC NC TT122.2 k1.0 k2.2 k33 k1.0 k122.2 k1.0 k2.2 k33 k1.0 k122.2 k1.0 k2.2 k33 k1.0 kNCNC122.2 k1.0 k2.2 k33 k1.0 k122.2 k1.0 k2.2 k33 k1.0 kNC NC TTTT21NC    NC4 | Terminal block removal12
Bosch Security Systems, Inc. F.01U.304.624 | 03 | 2015.01 | 37c |  No EOL resistorsHILOLEDPIR1      2     ONEN Grade 21      2   ON9 | Look-down feature8 |  DIP switches10b |  Microwave adjustment10a |  Walk test2 min2 s 2 s1321210c | Repeat walk test2 min2 s 2 s132NC NC TT122.2 k1.0 k2.2 k33 k1.0 k
Bosch Security Systems, Inc.130 Perinton ParkwayFairport, NY 14450USAwww.boschsecurity.comen   Installation GuideCommercial Series TriTech detectors  ISC-CDL1-W15G,ISC-CDL1-W15H, ISC-CDL1-W15K© 2015 Bosch Security Systems, Inc.     F.01U.304.624 | 03 | 2015.01Bosch Sicherheitssysteme GmbHRobert-Bosch-Ring 585630 GrasbrunnGermanyVoltage (operating)9 to 15 VDC, 9-15 V9-15 Vccde 10 à 15 mA @ 12 Vcc en veille/en alarme, source limitée en puissance, ondulation résiduelle 1 V.Current (maximum)<35 mAAlarm relay /Tamper<100 mA, 25 V  , 2.5W         Operating temperature-30°C to +55°C (-22°F to +130°F)UL 0°C to +49°C (+32°F to +120°F)AFNOR/CNPP -10°C to +55°CRelative humidity95% non-condensingUL and C-UL 93%CopyrightThis document is the intellectual property of Bosch Security Systems, Inc. and is protected by copyright. All rights reserved.TrademarksAll hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly.Bosch Security Systems, Inc. product manufacturing datesUse the serial number located on the product label and refer to the Bosch Security Systems, Inc. website at http://www.boschsecurity.com/datecodes/.0 m 2 m 4 m 6 m 8 m 10 m15 m0 ft 7 ft 13 ft 20 ft 26 ft 33 ft50 ft0 m7.5 m6 m4 m2 m0 m2 m4 m6 m7.5 m0 ft25 ft20 ft13 ft7 ft0 ft7 ft13 ft20 ft25 ft≥2.3 m ≥7.5 ft≤2.75 m ≤9 ft12 m39 ft14 m46 ft90°Region Agency Certifi cationUS FCC FCC Part 15 Class BUL -W15G: Intrusion Detection Unit Type: SCanada CUL -W15G: Intrusion Detection Unit Type: SIC 1249A-CDL1Europe CENELEC EN 50131-2-4EN 50130-5Environmental Class II, Grade 2 / IP41 / IK04 (EN60529, EN 62262)France AFNOR/CNPPNF&A2P (ISC-CDL1-W15H seulement)ISC-CDL1-WA15H Cert # xxxxxxxxxxxxRTC 50131-2-4NF-324-H58 2 boucliers – 110P2AFNOR Certifi cation:  www.afnor.orgCNPP Cert.:  www.cnpp.comAutosurveillance à l’ouverture Immunité champ magnétiqueGermany VdS VdS GxxxxxxClass B2110EN Enviromental Class 2Belgium ANPI/INCERTINCERT B-509-00xx/a:  (ISC-CDL1-W15G)Australia ACMA RCMItaly IMQ Certifi cato IMQ sistemi di sicurezza 3° livello di prestazione secondo CEI79-2:1998 + Ab:2000 (modello W15G)Sweden SBSC For svensk installationsanvisning se www.boschsecurity.se11 | Certifi cations  12 | Specifi cations 13 | Coverage pattern

Navigation menu