Bosch Security Systems 0407-6 User Manual Prog

Bosch Security Systems Inc Prog

manual

Installation InstructionsRF835 TriTech®Microwave/PIR Intrusion Detectorwith Pet Immunity7/99Copyright © 1999 Detection Systems, Inc.RF835 Installation Instructions P/N 40142ADetection Systems, Inc., 130 Perinton ParkwayFairport, New York, USA 14450-9199(716) 223-4060 • (800) 289-0096 • Fax: (716) 223-91801.0  OverviewThe RF835 TriTech® detector uses passive infrared technology, Micro-wave technology, and artificial intelligence to detect motion and pro-vides freedom from false alarms.  When motion is detected the unitsends an alarm signal to the control panel.2.0  SpecificationsGeneral•Power supplied by four 1.5V AA Alkaline Batteries.•Typical current draw is 100 micro-amps with LED disabled.•Typical battery life is two to three years (has not been verified byUnderwriters Laboratories).•Operating temperature range of +32°F to +120°F (0°C to +49°C)•Microwave Frequency: 10.525 Ghz (U.L. Listed)•RF Transmit Frequency: 304.00 MHz•Options: Low Profile Swivel Mount Bracket (use of this bracket mayreduce range and dead zone areas).3.0 InstallationTriTech Motion Sensor•Coverage area 35 ft. by 35 ft. (10.7 m by 10.7 m)•Internal coverage pointability -6°  to -10° Vertical and ±10° Horizontal.•Masking kit provided to block portions of coverage area.•Field selectable sensitivity options of Standard and Intermediate.•Three minute transmitter lockout time after alarm extends battery life.•Timed Walk Test Mode automatically disables LED after setup to extendbattery life.•Cover activated Tamper indication. Optional wall activated Tamper isincluded.•Pet Immunity capabilities have not been verified by UL.RF Transmitter•Integral RF transmitter capable of transmitting 500 feet open air.  (Actualacceptable transmitter range should be verified for each installation).•Transmits low battery report (trouble) to the control panel.•Transmits tamper•Transmits supervisory signal to the control panel every 64 minutes.3.1  Open the cover 3.2  Open base 3.3  REMOVE BATTERY PLUG3.5 Observe the Pet Immunity mounting recommendations6.5 Ft(2 M)Mount the detector 6 1/2 feet(2 meters) above the floorNODon'tpointatstairsDon'tpointwherepetscanclimbNO3.6 Avoid:Hot or cold airdirected ontosensorDirect orreflectedsunlightMoving objectsMoisture3.7  Observe the Pet Immune  Area 3.8 Observe Receiver RangeUpperareasarenotpetimmunePet Immune AreaOKNO500’ max(300 meters)Panel ReceiverInsert four (4)size AA Alkalinebatteries in thebattery holder perthe guides imprintedon the holderNotchesInsertscrewdriverinto notchesand gentlytwist to open3.4  Select a mount-ing locationDO NOT MOUNTOUTDOORSPRELIMINARY
 Page 2                                                                       Copyright © 1998 Detection Systems, Inc.                               RF835 TriTech Installation Instructions3.9  Mount the Detector 3.10  Set the Vertical Adjust 3.11  Set the PIR Sensitivity3.14  Adjust the Microwave3.16  CoveragePatternsFeet0 5 10 15 20 25 30 350510152051015200Meters1.6 3.2 4.8 6.4 8 9.6 11.2BCDEHIJKNOPQRSTUWXTOP VIEWLZFGLZ100Feet0 5 10 15 20 25 30-5°SIDE VIEW0Meters1.6 3.2 4.8 6.489.6351Remove masking for Look Down zone.B-LN-QR-U,ZW-XLZBCDEFGHIJKLNRWSOZPTXUQRF835 TriTech LensPattern Testing in Walk Test ModeRemoving and replacing the cover will start a 90 second WalkTest Mode. During this Test Mode, any activity in the sensor’s cov-erage pattern will cause a transmitted alarm and LED activation.Each alarm will also extend the Test Mode for an additional 90seconds.6.0  Other InformationMaintenance:  At least once a month, the range and coverageshould be verified using the walk test mode.  To ensure continualdaily operation, the end user should be instructed to walk throughthe far end of the coverage pattern.  This ensures an alarm outputprior to arming the system.Pattern Masking:  The PIR coverage pattern may be maskedusing the masking stickers provided with the unit.NOTE: Masking only eliminates the PIR portion of the coverageand has no effect on the Microwave pattern.U.S. Patent Numbers: #4,660,024, #4,764,755, #5,077,548,#5,208,567, #5,262,783, and #5,450,062. Other patents pending.FCC NoticeThis device complies with Part 15 of the FCC Rules and with RSS-210 ofIndustry and Science Canada. Operation is subject to the following two con-ditions: (1) this device may not cause harmful interference, and (2) thisdevice must accept any interference received, including interference thatmay cause undesirable operation.  Changes or modifications not expresslyapproved by Detection Systems, Inc. can void the user's authority to operatethe equipment.Mounting RangeHeight 20 ft. (6.1 m) 35 ft. (10.7 m)6.5 ft. (2 m)* -7 -5*7.0 ft. (2.1 m) -9 -68.0 ft. (2.4 m) -10 -7* Required for pet immunity.4.0  ProgrammingSee your Control Panel Programming Guide for information.5.0  Setup for Non-Pet ApplicationsSelect the vertical starting angle from the chart.  To adjust the verticalstarting angle for the desired mounting height and range, loosenthe vertical adjust screw and slide the board up, to point the PIRpattern down.  Note the settings on the vertical adjust scale (Figure3.9).NOTE: The vertical angle must be set at -5° for installations contain-ing pets.NOTE:During the warm-up period, the tricolor LED will flash red untilthe unit has stabilized (approximately 30 minutes) and hasseen no movement for two seconds. When the LED stops flash-ing, the detector is ready to be tested. With no motion in theprotection area, the LED should be OFF. If the LED is on, re-check the protection area for disturbances affecting the Micro-wave (yellow) or PIR (green) technologies. (See Figure 3.11.)3.15  Uncover Look Down Lens3.12  LED OperationLED Condition CauseSteady Red Unit AlarmSteady yellow Microwave Activation (walk test)Steady Green PIR Activation (walk test)Flashing Red Warmup Period After Power-UpFlashing Red (four-pulse sequence) Microwave or PIR failure.Replace Unit.3.13  Walk TestGreen =PIR detectYellow =MW detectRed =AlarmReplace coverWait 30 minutes after installingbatteries to begin Walk test.INTSTD- 6- 10MWMINMAXPIRSensitivitySelection PinsFor pet applications,set jumper to STD.INTSTDINTSTDINTSTDINTSTD- 6- 10MWMINMAX Peel awaythe maskIn non-pet applications only, if look-down isdesired, peel away thelook-down mask.Do not removethe clearplasticlens.INTSTDMINMAX MINMAXSet Microwave to MINIf necessary,adjust the MicrowaveSet as lowas possible fornormal operationLoosenthe VerticalAdjust Screw.Adjust the board to - 5(Refer to section 5.0)INTSTDVertical Adjust Screw- 6- 10- 6- 10MWMINMAXThinwallbreakaway forwall tamperswitchFlush mountCorner mountCorner mount

Navigation menu