Bosch Security Systems 012 RADION Door Window Sensor ZB User Manual

Bosch Security Systems, Inc. RADION Door Window Sensor ZB Users Manual

Users Manual

The detector requires 1 battery to operate, which is pre-installed in the detector. Powering up the detector:• Remove the battery isolation pull tab from theback of the detector. The detector powers up,and the green LED lights. The detector enterspairing mode when the green LED beginsflashing 3 times every 5 seconds. Continuewith Section 4.1, Pairing process.4 | InstallationThe LED provides feedback during installation or test mode.4.2 | LED behaviorLED ConditionFlashing • Flashes at a variable rate indicatesmagnetic field strength• Flashes 3 times every 5 secondsduring a 2 minute intervalindicates pairing modeGreen Good wireless signal strength performance Red Poor wireless signal strength performance Off • Normal operation and use• Optimal magnet gap distance• 90 seconds of inactivity duringtest mode4.1 | Pairing processNOTICE!Verify that the home automation or security system is powered up and operating. Then, put the system or control panel into pairing mode. Pairing the detector with the controller:1. With the detector in pairing mode (green LEDflashing after powering up), go to the homeautomation or security system and completethe pairing process according to the systemmanufacturer’s instructions. The manufacturerenrollment process might require additionaltime for discovery, moving the magnet, ortampering the detector (open and closedetector cover) to trip the detector and re-enterpairing.2. When pairing is complete, the detector enterstest mode, and is ready for installation.Identify and test desired mounting locations before you permanently install the detector and magnet. Refer to Section 3 for installation guidelines. Mounting the detector and magnet:1. Ensure the detector is in test mode.2. Select a location for the detector on astationary surface of an interior door orwindow frame.4.3 | Mounting and testing Figure 4.1: Correct alignment and placementFigure 4.2: Detector and magnet mounting with screws4.5 | Thin window mountingUse this procedure for special applications, such as thin windows where the magnet cover may prevent the window from opening.Installing on thin windows:1. Remove the base of the magnet by insertinga small flat head screwdriver or similar tool inthe slots on either end of the magnet base andcarefully pry off.2. Pry out the enclosed magnets from the magnetcover using a small flat head screwdriver orsimilar tool. See Figure 4.4.4.4 | Bracket mountingThe mounting bracket allows mounting of the magnet on its left or right side (90°), instead of its base. For example, use the mounting bracket for installations where the detector is mounted to the inside of a door frame. Refer to Figure 4.3. Using the mounting bracket:1. Remove the base of the magnet by insertinga small flat head screwdriver or similar toolin the slots on either end of the magnet baseand carefully pry off.2. Push the magnet cover onto the bracket.3. Add a tape strip to the bottom of the bracket4. If using screws, mount the bracket first, thenreplace the magnet cover. Refer to Figure 4.3.The exception is double hung windows, where the detector is mounted to a moving sash. Temporarily mount the detector.  3. Place the magnet near the detector and moveit to the desired mounting location, makingsure the alignment marks on the detectorand magnet align. Place the magnet anddetector side by side, and as close togetheras possible. The LED flash rate indicates thestrength of the magnetic field. The LED turnsoff at the optimal placement of the magnet tothe detector. Temporarily mount the magnet.The recommended magnet gap distance is0.75 inches (19.05 mm).4. To verify proper wireless signal strength, openthe door or window and check the color of theLED. If the LED is green, the signal strengthis acceptable. If the LED is red, reposition themagnet and detector, then recheck the LEDcolor. When the device RSSI (Received SignalStrength Indicator) or LQI (Linked QualityIndicator) level is poor, the LED is red. Referto Section 4.2, LED Behavior.5. Open the door or window to test for properclearance, and alarm operation. When thedistance between the detector and magnet isgreater than or equal to 1.3 inches (33 mm),the alarm triggers.6. When the location is acceptable, permanentlymount the detector and magnet using thedouble-sided tape on the base. If using screwsfor mounting, remove the detector and magnetcovers to access the mounting holes. You mayhave to remove the tape on the bottom of thedetector and magnet bases to mount flushon the surface. Refer to Figure 4.2 for surfacemounting, Section 4.4, and Section 5 forremoving the magnet and detector covers. Foradditional security, use an adhesive with thescrews when mounting.Figure 4.3: Mounting bracket using screws</= 3.0 cm(1.3 in)3. Remove the round perforated section of tapefrom the base of the detector.4. Attach the round section of tape to 1 magnetand place the magnet on the window oppositethe detector. Use the alignment mark on thedetector to align and center the magnet withthe detector.Figure 4.4: Remove magnet from magnet coverNOTICE!If the system does not discover the detector within 2 minutes, the detector exits pairing mode. Restart pairing mode by either opening/closing the detector cover, moving the magnet, or powering the detector off, then on.Figure 3.1: Door/window installation locations3 | Installation considerations – Suitable flat surfaces for installation include wood, metal, vinyl, glass, and painted surfaces. – Installation on metal surfaces can affect the wireless propagation pattern of the radio transceiver. – Verify proper clearance with the latch of the window or door and the detector. Failure to do so might make it difficult to access and open the detector for maintenance. – Moving the home automation or security system may improve wireless communication range performance. In some instances, installing another device, such as a repeater, might be required. 2 | Product contentsThe product box contains: – 2 detectors with installed batteries  – 2 magnets – 2 mounting brackets  – 2 tape strips for mounting brackets – Installation instructionsThe RADION contact ZB Door Window Detector is a surface-mount wireless detector for monitoring door or window position (open or closed). The ZigBee® compatible radio allows connection to a security or home automation system. The detector also monitors temperature, and includes tamper detection.1 | Overview PRELIMINARY
© 2017 Bosch Security Systems, Inc. F.01U.330.365 | 00e | 2017.03en  Installation Manual fr   Guide de l’installateurBosch Security Systems, Inc.130 Perinton ParkwayFairport, NY 14450USAwww.boschsecurity.comBosch Sicherheitssysteme GmbHRobert-Bosch-Ring 585630 GrasbrunnGermanyRADIONcontact ZB Door Window Detector RFDW-ZBMSCopyrightThis document is the intellectual property of Bosch Security Systems, Inc. and is protected by copyright. All rights reserved.TrademarksAll hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly.Bosch Security Systems, Inc. product manufacturing datesUse the serial number located on the product label and refer to the Bosch Security Systems, Inc. website at http://www.boschsecurity.com/datecodes/.FCCThis device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: – Reorient or relocate the receiving antenna. – Increase the separation between the equipment and receiver. – Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. – Consult the dealer or an experienced radio/TV technician for help.ICUnder Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d’un type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité nécessaire à l’établissement d’une communication satisfaisante.9 | SpecificationsFrequency (operating)2.4 GHzMax power transmitted 20 dBmBattery replacement         (1 per detector)3 VDC  ≥ 750mAh Energizer CR2 Lithium Duracell Ultra CR2 Lithium Panasonic CR2 Lithium Sanyo CR2 LithiumBattery life ≥ 5  years with 16 open/close alarm events per dayDimensions (detector)1.8 in. x 0.92 in. x 0.79 in. (46.0 mm x 23.5 mm x 20.3 mm)Dimensions (magnet)1.8 in. x 0.32 in. x 0.79 in. (46.0 mm x 8.3 mm x 20.3 mm)Temperature (operating)-4°F to +122°F(-20°C to +50°C)Storage temperature14°F to +131°F (-10°C to +55°C)Relative humidity5% to 93% at +32°C (+90°F)Magnet gap break distance≥ 1.3 in. (33 mm) mounted to metal, vinyl, or woodAgency CertificationControl No.3170792Conforms to ANSI/UL Std. 634 ULC/ORD-C634-86FCC FCC ID: T3X-012IC IC ID: 1249A-012This ZigBee® Certified product works in global 2.4 GHz networks supporting ZigBee HA 1.2.1. ZigBee® Certified is a registered trademark of the ZigBee Alliance.ZigBee® Cert No.xxx8 | Certifications7 | TroubleshootingA trouble status reported on the controller might be the result of low batteries on the detector. To trouble-shoot the condition, begin by replacing the batteries. Refer to Section 5 for replacing the batteries.Monitor the LED for issues when pairing or mounting the detector and magnet. The LED flashing pattern indicates wireless strength or magnetic field strength depending on color. Refer to Section 4.2 for LED behavior._+CR2 Figure 6.1: Tamper switch and battery orientation in detectorResetting the detector:1. Open the detector and remove the battery.Refer to Section 5 for opening the detector.2. Push and hold the tamper switch, and reinsertthe battery. When the green LED turns on,release the tamper switch before the greenLED turns off (within 4 seconds). Refer toFigure 6.1.3. The LED turns off, then turns on for 2seconds, and starts the pairing sequence(indicated by 3 LED flashes). The detector isnow reset to factory defaults. See Section 4.1for pairing process.4. Close the cover. Refer to Section 5 for closingthe detector.6 | Resetting the detectorNOTICE!You can reset the detector remotely using the supporting controller.NOTICE!Bosch is committed to responsible environmental stewardship. Please dispose of batteries in accordance with local laws and regulations in your area. Contact your local waste disposal authorities or consult  www.ecyclingcentral.com to find an electronics recycling center near you.Replacing the battery:1. Open the detector by pushing in the 2 buttonson both sides of the cover, while pulling thebase.2. Remove the old battery.3. Refer to the diagram on the inside cover forcorrect polarity orientation, then insert thenew battery. The green LED lights. Refer toFigure 6.1.4. Close the detector by pushing the detectorcover onto the detector base until the buttons“click” into place and secure the cover.5 | Battery replacementPRELIMINARY

Navigation menu