Bosch Connected Devices and Solutions CISS Connected Industrial Sensor Solution User Manual CISS v1 3 2017 05 10 indd

Bosch Connected Devices and Solutions GmbH Connected Industrial Sensor Solution CISS v1 3 2017 05 10 indd

User Manual

Connected Industrial Sensor Solution(CISS)Robert Bosch GmbHTübinger Straße 12372762 ReutlingenGermanyTelephone +49 711 35 0Fax +49 711 35 1689www.bosch.comPrinted in Germany100 % chlorine free paperde Bedienungsanleitungen  Operating Instructions 0274VM0944 v1.3
Revision HistoryIssue Date Description of Amendment1.0 11.04.2016 Initial Version1.1 26.06.2016 First Release1.2 29.01.2017Update sensors AKU removed, Charging temperature addedDoC 2014/53/EU removed 1.3 24.01.2017 FCC Statement of Conformity added2 | CISS-R2 deutsch CISS-R2 | 3Robert Bosch GmbH 0274VM0944 v1.3 | 01.2017
1.6 Technische DatenBezeichnung WertTemperaturbereich (im Betrieb) -20 – 60 °C (mit Akku); -20 – 85 °C (ohne Akku)Temperatur (beim Laden)    0 – 40 °CLagertemperaturbereich -20 – 60 °C Luftdruck 50 – 110 kPa (mit Akku); 30 – 110 kPa (ohne Akku)Luftfeuchte 10 – 90 %, nicht kondensierendSchutzklasse IP 54 nach IEC 60529Betriebsspannung 5 V GleichspannungStromaufnahme 150 mA maximalSendeleistung 2,5 mW maximalBLE-Frequenzband 2,402 – 2,480 GHz1 ÜberblickMitgeltendes Dokument: User Manual 0274Y05390 1. 1 Einsatzzweck der CISSDie CISS (Connected Industrial Sensor Solution) ist eine drahtlose Multisensorplattform für „Industrie 4.0“- Anwendungen. Die CISS überträgt Sensordaten an ein Gateway (WebApp), einen PC oder eine Mobile App. 1.2 Lieferumfang•  4x Connected Industrial Sensor Solution (CISS) mit vorinstallier-    ter Software (Akku bzw. DAE-Folie sind optional)• 4x Lade- und Kommunikationskabel• Installationsanleitung (User Manual 0274Y05390  als PDF    auf Gateway verfügbar)•  Befestigungsmaterial (je CISS 2 Schrauben, Scheiben und Magnet-    füße)1.3 Spannungsversorgung• Über USB, 5 V, max. 150 mA Stromaufnahme1.4 Sensorik•  Beschleunigung•  Drehrate•  Magnetfeld•  Feuchtigkeit/Luftdruck/Temperatur•  Umgebungslicht1.5 Kommunikation• USB für Firmwareupdates und Messdatenübertragung•  Bluetooth Low Energy (Bluetooth 4.0) für Konfiguration und Mess-  datenübertragung  4 | CISS-R2 deutsch deutsch CISS-R2 | 50274VM0944 v1.3 | 01.2017 Robert Bosch GmbH Robert Bosch GmbH 0274VM0944 v1.3 | 01.2017Kurzschlussgefahr!Eindringende Flüssigkeit kann das Gerät beschädigen und Kurz-schlüsse auslösen. In diesem Fall besteht Brandgefahr.• Lassen Sie keine Flüssigkeiten in die CISS eindringen.• Betreiben Sie das Gerät nur innerhalb der angegebenen Spezifikationen.HinweisLithium-Ionen-Akku!Das Gerät enthält einen Lithium-Ionen-Akku. Unsachgemäße Behandlung kann zu einem Brand führen.• Schützen Sie die CISS vor Schlägen oder Stößen.• Beachten Sie gegebenenfalls die geltenden Transportvorschriften.HinweisGarantieverlust!Durch unbefugtes Öffnen des Gehäuses können Gefahren für den Benutzer entstehen. Der Garantieanspruch, soweit vorhanden, erlischt.• Öffnen Sie das Gehäuse nicht.• Verwenden Sie nur originales oder freigegebenes Zubehör.HinweisFunktionseinschränkungen!Das Gerät kann beeinträchtigt oder beschädigt werden, wenn die Anschlüsse nicht korrekt verbunden werden.• Verwenden Sie ausschließlich das Original-Anschlusskabel.• Verwenden Sie ausschließlich eine 5 V DC USB-Spannungsquelle.Hinweis
2  Anschluss und Inbetriebnahme2.1. Befestigung Die CISS ist in einem Automotivegehäuse verbaut.  Verwenden Sie für die Befestigung die mitgelieferten Schrauben und Scheiben. Wenn Sie die mitgelieferten Magnetfüße verwenden wollen, verschrau- ben Sie die mitgelieferten Füße mit den vorhandenen Schrauben auf der Unterseite der CISS. Setzen Sie anschließend die CISS auf eine magnetisch anziehende Oberfläche auf.2.2. InbetriebnahmeVerbinden Sie das mitgelieferte USB-Verbindungskabel mit der CISS und einer USB-Spannungsquelle (z.B. PC oder Netzteil). Die CISS ist nun betriebsbereit. Die Datenlogger-Anwendung ist bereits vorinstalliert und kann über die WebApp des Gateways konfiguriert werden (s. 2.3.2 bzw. User Guide). Für jede Anwendung der CISS ist eine entsprechende Firmware nötig, die bei Auslieferung vorinstalliert ist. Ein Wechsel der Anwendung erfordert ein Firmwareupdate (s. 2.3.4 bzw. User Guide).2.3. DatenaustauschDer Datenaustausch kann über drei Wege erfolgen:•  Mobile App (nur Anzeige)•  Gateway (Raspberry Pi) •  PC2.3.1 Mobile App (Beta-Version)Kommunikationsweg: Bluetooth Low EnergyOptionen: Konfiguration2.3.2 Gateway Kommunikationsweg: Bluetooth Low EnergyOptionen: Konfiguration der CISS, Messdatentransfer zum Gate-way und Übertragung in die Sensor Cloud 6 | CISS-R2  deutsch deutsch   CISS-R2  | 70274VM0944 v1.3 | 01.2017 Robert Bosch GmbH  Robert Bosch GmbH 0274VM0944 v1.3 | 01.20172.3.3 PCKommunikationsweg: USBOptionen: Firmware-Update, Messdatenübertragung2.3.4 FirmwareupdateFür jede Anwendung der CISS ist eine entsprechende Firmware- datei nötig. Diese Datei (*.cis) enthält die Binärdatei für den Micro- Controller der CISS sowie die Authentifizierung und die Prüfsum-men, um ein korrektes Firmwareupdate zu gewährleisten.Führen Sie die folgenden Schritte für ein Firmwareupdate durch:• Verbinden Sie das mitgelieferte Kommunikationskabel mit einem      PC und der CISS. Der PC erkennt die CISS als Wechseldatenträ-    ger. •  Kopieren Sie die Firmwaredatei (*.cis) direkt, d.h. ohne Unterordner    auf die CISS. Verwenden Sie nur eine von Bosch bereitgestellte   Firmwaredatei.•  Verwenden Sie die Funktion „Hardware sicher entfernen“ und tren-     nen Sie die CISS vom PC. Das Firmwareupdate wird automatisch durchgeführt. Die auf die CISS kopierte Firmwaredatei wird bei erfolgreichem Update in *.old um- benannt. Bei nicht erfolgtem Update wird die Firmwaredatei in *.err umbenannt. Falls die Firmwaredatei korrumpiert ist, wird dies durch *.inv kenntlich gemacht.Entsorgungshinweis gemäß ElektroG und WEEE Richtlinie 2012/19/EUDie CISS sowie sämtliche Einzelteile dürfen nicht im Hausmüll entsorgt werden. Sie sind verpflichtet, die CISS sowie sämtliche Einzelteile nach Gebrauch einer Rückgabestelle oder einer Sammlung für die An- nahme und das Recycling von elektrischen und elektronischen Altgeräten zuzuführen.
9 | CISS-R2  englishRobert Bosch GmbH 0274VM0944 v1.3 | 01.2017deutsch 6 I CISS-R20274VM0944 v1.3 | 01.2017 Robert Bosch GmbHEG-KonformitätserklärungHersteller:     Robert Bosch GmbH    Tübinger Straße 123  72762 ReutlingenProdukttyp:   Connected Industry Sensor SolutionBezeichnung: CISS-R2Hiermit erklären wir, in alleiniger Verantwortung, dass das oben genannte Produkt den einschlägigen Bestimmungen der nachfolgenden Richtlinien entspricht: Richtlinie 1999/5/EG über Funkanlagen und Telekommunikationsendeinrichtungen  Richtlinie 2011/65/EU zur Beschränkung der Verwendung bestimmter gefährlicher Stoffe in Elektro- und ElektronikgerätenBei einer nicht mit uns abgestimmten Änderung des Produkts verliert diese Erklärung ihre Gültigkeit.Die folgenden harmoniserten Normen wurden angewandt:EN 60950-1:2006+A11:2009+A1:2010+AC:2011+A12:2011EN 300 328      V1.9.1:2015-02 EN 301 489-1   V1.9.2:2011-09 EN 301 489-17 V2.2.1:2012-09EN 62479:2011-09Reutlingen, 24.01.2017                                     Karsten Neurohr (AE/PJ-I40)1 OverviewSupplementary document: user manual 0274Y053901. 1 Intended UseThe CISS (Connected Industrial Sensor Solution) is a wireless multi- sensor platform for Industry 4.0 applications. The CISS transmits sensor data to a gateway (WebApp), a PC, or a mobile app.1.2 Included in Delivery•  4x Connected Industry Sensor Solution (CISS) with pre-installed     software (battery and PCS film optional)•  4x Charging and communication cable•  Installation instructions (user manual 0274Y05390 in PDF format     available on the gateway)• Fasteners (for each CISS: 2 screws, 2 washers, and 2 magnetic     bases)1.3 Power Supply• Via USB, 5 V, up to 150 mA current consumption1.4 Sensors• Accelerometer• Gyroscope• Digital compass• Environment sensor for humidity/barometric pressure/tempe-  rature• Ambient light sensor1.5 Communication• USB for firmware updates and measurement data transmission• Bluetooth Low Energy (Bluetooth 4.0) for configuration and    measurement data transmissionenglish   CISS-R2  | 9
1.6 Technical SpecificationsName ValueTemperature (operating) -20 – 60 °C (with battery); -20 – 85 °C (without battery)Temperature (charging)    0 – 40 °CStorage Temperature Range -20 – 60 °CHumidity 10 – 90 %, non-condensingAir Pressure 50 – 110 kPa (with battery); 30 – 110 kPa (without battery)IP Rating IP 54 (IEC 60529)Voltage 5 V DCCurrent Consumption up to 150 mATransmitting Power 2.5 mWBLE Frequency Band 2.402 – 2.480 GHz11 | CISS-R2  englishRobert Bosch GmbH 0274VM0944 v1.3 | 01.2017english10 | CISS-R20274VM0944 v1.3 | 01.2017 Robert Bosch GmbH2  Connection and Putting into Operation2.1. Attachment  The CISS is built into an automotive housing.Use the screws and washers included in delivery to mount the CISS to the desired position.If a magnetic mounting is required, apply the included screws to the bottom of the CISS. With these screws applied, the CISS can be moun-ted to any magnetic surface.2.2. Putting into OperationConnect the USB cable included in delivery to the CISS and to the USB power supply (such as a PC or a power adapter). The CISS is now ready to be put into operation:The data logger application is pre-installed and can be configured in the WebApp of the gateway (see 2.3.2 or the user guide).Corresponding firmware is required for each CISS application. This firmware is pre-installed when delivered. A change of the application requires a firmware update (see 2.3.4 or the user guide).2.3. Data TransferData can be transferred in three ways:•  Mobile app (data display only)•  Gateway (Raspberry Pi) •  PC2.3.1 Mobile App (Beta Version)Communication channel: Bluetooth Low EnergyOptions: Configuration2.3.2 Gateway Communication channel: Bluetooth Low EnergyOptions: Configuration, measurement data transmission to the gateway and transfer to the Sensor CloudRisk of Short Circuits!Liquid which enters the device can damage the device due to short    circuits. This causes the risk of fire. • Do not allow any fluids to enter the CISS.• Use the device only as specified.  NoticeLithium-Ion Battery!The device contains a lithium-ion battery. Incorrect handling of the battery causes the risk of fire. • Protect the CISS from mechanical shocks and impacts.• Read and follow the valid transportation regulations, if necessary.NoticeVoiding the Warranty!Opening of the housing without authorisation causes risk to the user and will void the warranty.• Do not open the housing. • Use only original or approved accessories.NoticeFunctional Limitations!The device can be impaired or damaged if the connections are not connected correctly.• Use only the delivered connection cable.• Use only 5 V DC USB power supply.Noticeenglish   CISS-R2  | 11
Robert Bosch GmbH 0274VM0944 v1.3 | 01.2017english12| CISS-R20274VM0944 v1.3 | 01.2017 Robert Bosch GmbH2.3.3 PCCommunication channel: USBOptions: Firmware update, measurement data transmission2.3.4 Firmware UpdateA corresponding firmware file is necessary for each CISS applica-tion. This file (*.cis) contains the binary data for the microcontrol-ler in the CISS as well as for both the authentication and the check- sums needed to guarantee that the firmware is updated correctly.Perform the following steps to update the firmware:• Connect the communication cable included in delivery to a PC     and the CISS. The PC detects the CISS as a mass storage device. •  Copy the firmware file (*.cis) directly (that means without a folder)    to the CISS. Use only firmware files provided by Bosch.• Use the “Remove hardware safely” function and unplug the CISS     from the PC.The firmware is updated automatically. If the update is successful, the firmware file copied to the CISS mass storage device is renamed to *.old. If the update is not successful, the firmware file is renamed to *.err. If the firmware file is corrupt, the file extension is changed  to *.inv.  Disposal according to the WEEE Directive 2012/19/EUThe unit, accessories and packaging should be sorted for environmental-friendly recycling. Do not dispose of the device into household waste! According to the European Guideline 2012/19/EU, electric and electronic devices that are no longer usable must be collected separately and disposed of in an environmentally correct manner.Declaration of ConformityManufacturer:   Robert Bosch GmbH    Tübinger Straße 123  72762 Reutlingen  GermanyProduct Type:  Connected Industry Sensor SolutionProduct Name:  CISS-R2 We hereby declare under our sole responsibility that the product described above complies with the relevant clauses of the following directives: Directive 1999/5/EC on radio equipment and telecommunications terminal equipment Directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment  Any modification to the product not expressly approved by the manufacturer shall void the validity of this declaration.The following harmonised standards have been applied:EN 60950-1:2006+A11:2009+A1:2010+AC:2011+A12:2011EN 300 328      V1.9.1:2015-02 EN 301 489-1   V1.9.2:2011-09 EN 301 489-17 V2.2.1:2012-09EN 62479:2011-09Reutlingen, 24.01.2017                                                Karsten Neurohr (AE/PJ-I40)english   CISS-R2  | 13
english14| CISS-R20274VM0944 v1.3 | 01.2017 Robert Bosch GmbHFCC Statement of ConformityNOTICE:This device complies with Part 15 of the FCC Rules.Operation is subject to the following two conditions:(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference         that may cause undesired operation. NOTICE: Changes or modifications made to this equipment not expressly approved by (manufacturer name) may void the FCC authorization to operate this equipment.Radiofrequency radiation exposure Information:This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body.This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. NOTE:  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.  However, there is no guarantee that interference will not occur in a particu-lar installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:•  Reorient or relocate the receiving antenna.•  Increase the separation between the equipment and receiver.•  Connect the equipment into an outlet on a circuit different from that    to which the receiver is connected.•  Consult the dealer or an experienced radio/TV technician for help.english   CISS-R2  | 15

Navigation menu