BodyMedia 908901PROD2 Physiological monitoring device User Manual Summary operating manual

BodyMedia, Inc. Physiological monitoring device Summary operating manual

Summary operating manual

body monitoring systemInstructions For UseSenseWear® softwareSenseWear® Professional softwareSenseWear® armbandand data collection
Introduction ........................................................2Important Information About the SenseWear® armband ............................3Retrieving armband Data to Your Computer   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Viewing and Analyzing the Data ..........................................13Viewing and Editing Health Indicators  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Advanced Graphing of the Data  ..........................................18Annotating the Data  ..................................................20Creating Reports  ....................................................22Exporting Data  .....................................................24Application Preferences  ...............................................24Using the Software to Congure an armband and display ..........................28Features of the SenseWear® armband .......................................32Important Troubleshooting Information  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43NOTE:Read these instructions and the Warnings and Cautions on pages 2-6 before using the Body Monitoring System.TABLE OF CONTENTS
2This manual will instruct you in the use of the SenseWear® Body Monitoring System™. It covers the routine operations and frequently-used  features of the SenseWear® software, SenseWear® Professional software and the  SenseWear® armband.If you have not done so already, please refer to the Getting Started Guide included in the System box to install the SenseWear software or SenseWear Professional software and congure the armband. After completing the initial set-up  (Step 3), you may proceed with this manual.     IMPORTANTTo run the SenseWear software or SenseWear Professional software, the minimum requirements for your PC are Pentium III or higher, with at least 256 MB of RAM, Windows 2000 SP3 or later/XP/Vista and a USB port for the armband connection. For the SenseWear Professional you will need an additional USB port to accommodate the license key. Intended UseThe SenseWear® armband can be used as a monitor for applications such as: nutritional diagnos-tics, metabolic diseases, pediatrics, pulmonary and cardiac studies, geriatrics, internal medi-cine, occupational medicine, neurology, psychiatrics, sleep screening, and in general anywhere it is necessary to monitor caloric and energy consumption, movement, physical activity, quality of life, lifestyle, behavior and/or stress.Important Information About the SenseWear® armbandIntroduction     WARNINGSThis product complies with the general requirements for a safe medical device under applicable directives. However, this product alone is not meant to substitute for proper medical diagnosis, care, or treatment. Clinicians should not make drastic changes to a user’s lifestyle based solely on data from the armband. The Body Monitoring System has been clinically validated for sub-jects between 7 and 65 years of age who are engaged in resting, ambulatory, stationary biking, motoring and weight-lifting activities, etc. Due to metabolic variations, subjects who are 1) out-
3     WARNINGSside this age range or 2) engaged in alternate or obscure activities may see decreased accuracy in the data. Any decisions based on the data from this device should be made only by medical or paramedic personnel and should consider the condition and lifestyle of the subject tested. The SenseWear® armband should not be used for life critical applications; improper usage may result in harm or even death to the wearer.This product is non-debrillation proof.Do not get the device close to other devices that can cause electromagnetic interferences of  any nature.EQUIPMENT not suitable for use in the presence of a FLAMMABLE ANAESTHETIC MIXTURE WITH AIR or WITH OXYGEN OR NITROUS OXIDE.Please be sure to verify equipment is connected and used compliant to UL1950.Medical electrical equipment needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided on pages 7-10. Portable and mobile RF communications equipment can affect medical electrical equipment.The equipment or system should not be used adjacent to or stacked with other equipment and if adjacent or stacked use is necessary, the equipment or system should be observed to verify normal operation in the conguration in which it will be used.The SenseWear® wireless communicator should not be used in airplanes, hospitals or locations where cellular telephones or electronic devices are prohibited.Keep the SenseWear® armband and wireless communicator out of reach of children. Both prod-ucts contain smaller, removable parts which can become chocking hazards.Important Information About the SenseWear® armband
4     WARNINGSImportant Information About the SenseWear® armbandWear comfortably Be careful not to over-tighten the armband while on your arm. If, at any time, you feel constric-tion or loss of circulation, simply loosen the adjustable strap and re-fasten it to a more comfort-able setting. Be sure that both your arm and the sensors on the back of the armband are cleaned daily. To clean the sensors, wipe with a soft, damp cloth. If you develop a rash where the armband comes in contact with your skin, discontinue use and consult your physician before continuing regular use of the armband. The design of the armband involved many materials experts, physicians, and suppliers who are familiar with wearable materials and products. Each material was chosen for its precedent in other skin contact products or has been independently approved for skin contact. However, everyone’s skin is different and wearers with very sensitive skin may experi-ence irritation or redness after wearing the armband. If this occurs, discontinue use and consult your physician. If you have known metals allergies, you should consult your physician prior to wearing. Do not wear armband when open sores are present Check armband for sharp edges or damage before each use. There have been reports of scratches/cuts associated with the Velcro tab of the strap. Also, excessively hot armbands, such as those left in a car in the summer, may cause skin burns if they are not allowed to cool before use.When the armband is on the arm, DO NOT connect it to the USB cable.Users with sensitive skin should avoid wearing the armband excessively. If you have sensitive skin, remove the armband 1 hour for every 24 hours of wear time to reduce potential for skin irritation.
5Water resistance DO NOT IMMERSE THE ARMBAND IN WATER. The monitor is not designed to be used underwater or to come in continuous contact with water. To prevent a shock hazard, never use the armband in water environments (e.g., in the shower, swimming pool, or rain). IPX0 classied. Ordinary Protection, not protected against ingress to moisture.Batteries Batteries may explode or leak and can cause burn injury if recharged, disposed of in re, or dis-assembled. Do not remove the battery label. Dispose of properly. For further information about the disposal of the battery, please follow manufacturer’s instructions.  Batteries may present a choking hazard for small children.Remove battery if armband will not be used for over 30 days.Handling Though the SenseWear® armband was designed for wearability and long-term use, it is a sensi-tive monitoring device. Rough handling can break internal components. Never drop or shock the armband and always store it in a safe place when not in use. Avoid exposing the armband to extreme temperatures, direct sunlight, moisture, sand, dust, or mechanical shock. To prevent possible damage to the USB cable, grasp the plug end when disconnecting the USB cable. Replace the cable if it becomes frayed.      WARNINGSImportant Information About the SenseWear® armband     CAUTIONS
6     CAUTIONSImportant Information About the SenseWear® armbandDispose of device in accordance with local, state, federal, or country specic regulations.  Maintenance Do not attempt to open the armband yourself. It contains no user-serviceable parts. Refer all servicing to qualied Service Personnel. Opening the armband yourself will void the warranty. Changes or modications to this equipment not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.If the armband is dropped, ensure that it is working properly and not physically damaged before relying on readings.Cleaning Always clean and dry the armband after vigorous sweating activities or when it becomes notice-ably moist or dirty. Failure to keep the armband clean, or improper cleaning, may irritate the skin and affect the sensor performance. Moisten a soft cloth or towel with mild disinfectant soap and water. Wipe and dry the skin-touch-ing side of the Armband. Never use solvents to clean the armband, only for disinfecting (see be-low). The adjustable strap should be hand-washed with mild soap and warm water, then air-dried. Machine drying may affect the performance and lifespan of the strap. Disinfecting Wipe back of armband with soft cloth dampened with 70% isopropyl alcohol. Allow armband to dry for 5-10 minutes before wearing DO NOT STERILIZE THIS UNIT.
7Flicker IEC 6100-3-3N/AHarmonics  IEC 6100-3-2N/A The 908901PROD2 is suitable for use in all establishments, including domestic, and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes.RF Emissions CISPR 11 Class B, Group 1 The 908901PROD2 uses RF energy only for its inernal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment.The 908901PROD2 (SenseWear® armband) is intended for use in the electromagnetic environment specified below. The customer or user of the 908901PROD2 should ensure that it is used in such an environment. Guidance and Manufacturer’s Declaration - EmissionsEmissions Test Compliance Electromagnetic Environment - GuidanceImportant Information About the SenseWear® armbandComputer and Wireless Communicator1.5mDiagram not to scale.1.5m 1.5m2.5mPatient Environment
83A/m Power frequency magnetic fields should be that of a typical commercial or hospital environment.Power  Frequency 50/60HzMagnetic FieldIEC 61000-4-8 3A/mN/A Mains power quality should be that of a typical commercial or hospital environment. If the user of the 908901PROD2 requires continued operation during power mains interruptions, it is recommended that 908901PROD2 be powered from an uniterruptible power supply or battery.Voltage Dips/DropoutIEC 61000-4-11>95% Dip for 0.5 Cycles60% Dip for 5 Cycles30% Dip for 25 Cycles>95% Dip for 5 SecondsN/ASurge IEC 61000-4-11±1kV Differential ±2kV Common Mains power quality should be that of a typical commercial or hospital environment.N/AEFT IEC 61000-4-4±2kV Mains ±1kV I/Os ±6kV Contact ±8kV AirFloors should be wood, concrete, or ceramic tile. If floors are synthetic, the r/h should be at least 30%.ESDIEC 61000-4-2±6kV Contact ±8kV AirThe 908901PROD2 (SenseWear® armband) is intended for use in the electromagnetic environment specified below. The customer or user of the 908901PROD2 should ensure that it is used in such an environment. Guidance and Manufacturer’s Declaration - ImmunityImmunity Test IEC 60601 Test LevelCompliance LevelElectromagnetic Environment - GuidanceImportant Information About the SenseWear® armband
9Important Information About the SenseWear® armband3 Vrms  150 kHz to  80 MHz3 V/m 80 MHz to 2.5 GHz3 Vrms  150 kHz to  80 MHz3 V/m 80MHz to  2.5 GHzPortable and mobile communications equipment should be separated from 908901PROD2 by no less than the distances calculated/listed below: D=(3.5/V1)(Sqrt P)   D=(3.5/E1)(Sqrt P)   80 to 800 MHz  D=(7/EI)(Sqrt P)   800 MHz to 2.5 GHz Where P is the max power in watts and D is the recommended separation distance in meters.FIeld strengths from fixed transmitters, as deter-mined by an electromagnetic site survey, should be less than the compliance levels (V1 and E1).Interference may occur in the vicinity of equip-ment containing a transmitter.•••Conducted RF IEC 61000-4-6  Radiated RF IEC 61000-4-3The 908901PROD2 (SenseWear® armband) is intended for use in the electromagnetic environment specified below. The customer or user of the 908901PROD2 should ensure that it is used in such an environment. Guidance and Manufacturer’s Declaration - EmissionsIEC 60601 Test LevelCompliance LevelElectromagnetic Environment - GuidanceImmunity Test
10Important Information About the SenseWear® armband0.1 0.3689 0.3689 0.7378The 908901PROD2 (SenseWear® armband) is intended for use in the electromagnetic environment specified below. The customer or user of the 908901PROD2 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF Communications Equipment and the 908901PROD2 as recommended below, according to the maximum output power of the communications equipment. Recommended Separations Distances for the 908901PROD20.01 0.1166 0.1166 0.2333Separation (m) 150kHz to 80MHzD=(3.5/V1)(Sqrt P)Separation (m)80 to 800MHzD=(3.5/V1)(Sqrt P)Separation (m)800MHz to 2.5GHzD=(7/E1)(Sqrt P)Max Output Power (Watts)1 1.1666 1.1666 2.333310 3.6893 3.6893 7.3786100 11.6666 11.6666 23.3333
11Retrieving armband Data to Your ComputerTo start the program, double-click on the SenseWear® software or SenseWear® Professional* software icon on your desktop. The main screen (gure 1) will appear as shown. There are three buttons at the top under the menu bar: Retrieve Armband Data, View & Annotate Armband Data and Congure Armband. Retrieve Armband Data will already be selected. gure 1Connect the USB cable to the armband and to one of your computer’s USB ports. Then click Retrieve to transfer data from the armband to your PC. A window will pop up (gure 2), requesting you to enter a le name. Enter a name and click Continue. The data le will be saved in your default directory.If you want to change the location of your default directory, click Browse and select a new destination directory. *SenseWear Professional software requires the License Key to be inserted into a USB port.gure 2     TIPWhen naming your les use numbers rather than names to protect your patients’ identities. For example, Patient1234.     IMPORTANTAfter the armband data has been successfully retrieved and saved to a data le, the data is cleared from the armband. If you want the data to remain on the armband then unselect the Clear armband for next use… checkbox before clicking Continue.
12Retrieving armband Data to Your ComputerIf the armband was not congured prior to wearing, you will receive a pop up window (gure 3) after the data has been retrieved. The window will prompt you to enter the wearer’s Subject Info and other important information needed to derive accurate lifestyle information. The subject information MUST be entered to ensure that the software can ac-curately analyze the raw data collected by the armband. (see Getting Started Guide, Step 2, Conguration).The software lets you know that you have successfully retrieved the data by a pop up message that appears on your screen (gure 4). The newly retrieved data will be displayed automatically.gure 3     TIPA new AAA battery can collect up to 14 days of continuous data. Keep in mind that the bat-tery life is reduced under colder conditions. To avoid losing data or interrupting a longer continuous data collection, pay particular attention to the battery level after retrieval (gure 4). As a rule of thumb, 50% battery life will last about 7 days and 25% battery life will last approximately 3 days. See page 32 for more information about battery life and how to check the level from the armband.gure 4
13Viewing & Analyzing the DataIf you have just retrieved data from the armband, then the data le will already be displayed. If you would like to view a previ-ously saved data le, go to File on your menu bar and select Open Data File. A window (gure 5) will open up to your default direc-tory. Double click on the data le you wish to open.gure 5On the View & Annotate Armband Data screen (gure 6), the total duration of the le and on-body data collection times is indicated on the interactive time selector (gure 7) on the upper right of your screen. The bottom half of the screen is a summary of the Lifestyle Indicators and Health Indica-tors. By default, the Lifestyle Indicators tab will be selected, displaying a summary of the derived armband data for the entire duration of the collected data le. Clicking on the Health Indicators tab will display a graph of any available biometric data (blood glucose, blood pressure, or weight) retrieved from the armband.     IMPORTANTSenseWear® software and SenseWear®  Professional software v. 6.0 are de-signed to work with SenseWear Pro2 and Pro3 armbands. The software does not support earlier armbands or data les by earlier armbands. gure 6
14Viewing & Analyzing the DataThe date and time located to the left and right just above the selector indicate the total duration of the data le. Inside the rectangle itself, the beginning of each day (midnight) within this duration is marked by the date and a thin vertical white line. Solid-colored areas show periods when the armband was on-body and collecting data. Thin horizontal grey lines show periods when the armband was off-body and not collect-ing data. The shorter dark blue vertical lines indicate that the Timestamp/Status button was pressed. You can highlight different time periods with-in the entire duration of the collected data with the time selector. To select only one day from the time selector, click anywhere on the day you wish to view. The selector will automatically select that day (midnight to midnight). To select multiple complete days click on the rst day you would like to view and shift-click on the nal day you want displayed. gure 7Start12:00 AMEnd12:00 AM     TIPTo select only one day from the interac-tive time selector (Figure 7), simply position your mouse on top of the day you wish to view and click. You can then drag the selected area to move this 24 hour time period. To select start and end times, drag the time selectors below the horizontal box. You can then move the selected time period by dragging the bar between the widgets. All values for these selected times will automatically update on the right.Click the Show Sessions and Timestamps checkbox under the Subject ID on the upper left of your screen for a chronological list of all on-body sessions and Timestamps. The list will appear in the window below the Subject ID. Clicking on a specic day or time on the list will also high-light that item in the interactive time selector.
30The armband Parameters tab (gure 27) allows you to verify the date and time of the armband clock. It also allows you to check the hardware version, serial num-ber, battery level, and memory capacity.Using the Software to Configure an armband and displaygure 27     IMPORTANTIf the armband clock is not synchronized with your PC clock, a message may suggest that you synchronize the clocks. If your PC clock time is the correct time, we recommend doing this by clicking the Apply button.     IMPORTANTIf using the optional SenseWear® display, be sure to have your PC clock set with the same time zone of the location you will be wearing the display. Because data is displayed in 24 hour increments, this will ensure the accuracy of your data. Please refer the SenseWear® display Operating Manual for proper usage.
31The SenseWear® Professional software includes the Data Channels tab (gure 22) feature. This tab lets you congure the data channels to be collected and the sampling rates used by each channel.If you are not familiar with the low-level physiological parameters the device collects, we strongly recommend not changing this section.gure 28Using the Software to Configure an armband and displayIf you need to clear memory from an armband, select Armband Maintenance (gure 23) from the menu bar at the top of your screen and select the appropriate command from the list.gure 29     IMPORTANTDo not select Reboot Armband unless instructed to do so by a BodyMedia representative or Technical Support Specialist. Unnecessary reboots of the device can result in data loss.SenseWear® Professional software
32BatteryThe armband is powered by one AAA battery. During continuous use (24/7), it will last approxi-mately 14 days. To check the status of the battery, remove the armband and press the Timestamp/Status button. The light above the word “battery” will turn on as follows: Green (solid) = More than 24 hours of battery life remains. Amber (ashing) = Less than 24 hours of battery life remains. Red (ashing) = Battery life is very low and the armband will not collect data. Change the battery before continuing use. If you are wearing the armband, a subtle vibration and sound will alert you when there is less than 24 hours of battery life remaining. When the battery is too low to operate, the alert will become more urgent. In addition to the battery status light on the armband, you can also view how much battery life is left every time you retrieve your data (Figure 4). •••To replace the battery, lift and rotate the top hatch counterclockwise. Remove the drained AAA battery and replace it with a new AAA battery immediately. Ensure proper disposal of batteries. Features of the SenseWear® armband+–     WARNINGOnce you remove the AAA battery, you have 30 seconds to replace it with the new one. Failure to do so may lead to loss of data.
33Memory Under default congurations, the armband has approximately 10 days of data collection mem-ory. To check the memory status, remove the armband and press the Timestamp/Status button. The light above the word “memory” will turn on as follows: Green (solid) = More than 24 hours of memory remains. Amber (ashing) = Less than 24 hours of memory life remains. Red (ashing) = Available memory is low and the armband will not collect data. Retrieve your data before continuing use. If you are wearing the armband, a subtle vibration and sound will alert you when there is less than 24 hours of memory life remaining. When the memory is full, the alert will become more urgent. Wearing your armband The SenseWear® armband is designed to be worn on the back of the upper right arm (the tri-ceps), touching the skin. Make sure that your upper right arm is clean and dry. You should not wear any lotion  or body oil where the armband will come in contact with your skin. Slide the armband onto the back of your upper right arm with the SenseWear logo  facing up. Adjust the strap so that it ts on your arm comfortably, then secure the oval pull-tab.  Flex the arm a few times to make sure that the strap is neither too tight nor too loose.  It should be snug, but comfortable. You do not need to adjust the strap again in the  future; just slide it on and off.•••1.2.3.Features of the SenseWear® armband     WARNINGBe careful not to overtighten the armband. If, at any time, you feel constriction or loss  of circulation, simply loosen the adjustable strap and refasten it to a more  comfortable setting.
34Features of the SenseWear® armbandThreading your adjustable strap Your SenseWear® armband comes with two identical adjustable straps. One strap comes at-tached to the armband and the other is a spare to be used if you’re cleaning the rst one. See the Cleaning section (page 6) of this manual for information on cleaning your adjustable strap. Follow these steps to thread your adjustable strap into your armband.Hold the armband upright with the sensors facing you. Take the square end of the adjust-able strap with the two Velcro® pads and thread it through the narrow, vertical slot in the wing. The Velcro® pads should be facing you, with the edge of the wing in between the two pads.Fold over the end of the strap and press the Velcro® pads together.Take the other end of the adjustable strap with the oval pull tab and thread it through the narrow, vertical slot in the other wing. The Velcro® side of the oval pull tab should be facing you.Pull the strap through the slot in the wing and press the oval pull tab against the adjust-able band. Create a space that is approximately the size of the circumference of your upper arm.When completed, the square end of the strap should be on the inside of the band and the oval pull tab should be on the outside of band. Use the oval pull tab to adjust the size of the strap while on your arm.1.2.3.4.5.Two AAA Batteries (Part No.###)     WARNINGDo not use unapproved accessories with the armband.
35Features of the SenseWear® armbandSenseWear® armband - Part No.100156 (US), 100153 (Europe-Italian),  100154 (Europe-English).Wearable body monitor with multi-sensor array collects data directly off skin  of the wearer’s arm. SenseWear® wireless communicator - Part No.100155 (US) and 100158 (Europe)Directly connects to computer to wirelessly retrieve data off of armband. USB Cable - Part No.100108 (US/Europe-English) and 100128 (Europe-Italian)Connects wireless communicator or armband to computer. SenseWear® armband Strap - Part No.100114 (Sm), 100115 (Med), 100116 (L)Spare strap for armband. Two AAA Batteries••••ABCDEBACED
36Features of the SenseWear® armbandArmband featuresGathers raw physiological data, including movement, heat ux, skin  temperature, near body temperature, and galvanic skin response. Battery lasts approximately 14 days when worn continuously. Stores approximately 10 days of continuous physiological and lifestyle data with default conguration. Product specications Sensors:  Accelerometer (2-axis) Heat Flux Skin Temperature Near Body Temperature Galvanic Skin ResponseMaterials: Monitor: ABS, urethane, FDA approved co-polyester, hypo-allergenic grade  stainless steel Wireless Station: ABS Adjustable Strap: Nylon, polyester, polyisoprene (no latex content) Battery type: 1 AAA battery Battery power: about 14 days under continuous use (24/7) Memory capacity: about 10 days under continuous use (24/7) with default congurations. Monitor size (without wings): (l) 85.3mm x (w) 53.4mm x (h) 19.5mm; [(l) 3.4 in x (w) 2.1 in x (h) 0.8 in] Monitor weight (with adjustable strap): 2.8 oz (79 g) Water resistance: splash-resistant Operating temperature/humidity: 0° C to +45° C (32° F to 113° F)/100% RH  non-condensing Storage temperature/humidity: 0° C to +45° C (32° F to 113° F)/100% RH non-condensingDesign and specications are subject to change without notice. ••••–––––•–––••••••••
37Features of the SenseWear® armbandSensor AccuracyAccelerometer(2-axis)Absolute range is +/- 2.00gThe minimum resolution is 0.01gA two-standard-deviation range of +/-0.05g, up to 1.00g on longitudinal axisA two-standard-deviation range of +/-12.00% of expected value otherwise on the longitudinal axisA two-standard-deviation range of +/-0.06g up to 1.00g on the transverse axisA two-standard-deviation range of +/-12.00% of expected value otherwise on transverse axis.••••••Heat Flux Range is from 0.00 W/m2 to 300.00W/m2A minimum resolution of 1.00W/m2A two-standard-deviation range of +/-10.00W/m2 at heat ux less than 50W/m2A two-standard-deviation range of +/-35.00% of expected value otherwise••••Galvanic Skin ResponseRange is from 56KW to 20MW  (50.00 nSiemens – 17.00 uSiemens)A two-standard-deviation range of +/- 7.00 nSiemen up to 233.34 nSiemens reading A  two-standard-deviation range of +/- 3.00% of expected value otherwise•••Skin Temperature Range is from 20.00ºC to 40.00ºCA minimum resolution of 0.05ºCA 2 standard deviation range of +/- 0.80°C across the  temperature range•••
38Features of the SenseWear® armbandFollow operating instructions. Caution TYPE B APPLIED PARTThe Waste Electrical and Electronic Equipment Regulations indicates  separate collection for electrical and electronic equipment.Tested to applicable safety standards.Identication code of Notied Body involved: 0051.Classication of the device, as per 93/42 directives : IIa (rule 10)Certication procedure : 93/42/EEC, Annex VI, VII.Identication code of Notied Body involved: 0051Transmit Power Class 8 - Less than 10mW output powerDuty Cycle Class 4 - permitted to operate at 100% duty cycle Receiver Class 3 - Standard reliable SRD communication media
39Features of the SenseWear® armbandFCC statementNOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit separate from  the receiver. Consult the dealer or an experienced radio/TV technician for help. CAUTION: Changes or modications to this equipment not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.FCC 47CFR 15C TCB - 47 CFR Part 15 Subpart C Intentional Radiator  Certication TestFCC 47CFR 15B clA - 47 CFR Part 15 Subpart B Unintentional Radiators Class A VericationUL 60601-1 - UL Standard for Safety Medical Electrical Equipment, Part 1:  General Requirements for Safety First EditionCENELEC EN 60601-1-2 - 2001 - Medical Electrical Equipment Part 1-2: General Requirements for Safety - Collateral Standard: Electromagnetic Compatibility - Requirements and Tests IEC 60601-1-2: 2001•••••
40Features of the SenseWear® armbandCENELEC EN 60601-1-1 - Medical Electrical Equipment - Part 1: General Requirements for Safety - Collateral Standard: Safety Requirements for Medical Electrical Systems.CAN/CSA-C22.2 No.606.1-M90ETSI EN 301 489-1 - Electromagnetic Compatibility and Radio Spectrum Matters (ERM); Elec-troMagnetic Compatibility (EMC) Standard for Radio Equipment and Services; Part 1: Common Technical Requirements V1.3.1 ETSI EN 301 489-3 - (Draft) Electromagnetic Compat. and Radio Spectrum Matters (ERM); Har-monized EN for ElectroMag. Compatibility (EMC) of Radio Comms. Equip. & Srvs.; Pt. 3: Specic Conditions for Short-Range Devices (SRD) Operating on Freqs Between 9 KHz and 40 GHz V1.3.1ETSI EN 300 440-1 V1.3.1 (2001-07)  Electromagnetic compatibility and Radio spectrum Matters (ERM);Short range devices; Radio equipment to be used in the 1 GHz to 40 GHz frequency range