RC66 Radio Receiver  focus on productivity    Radio transmission  for touch probes                                     Installation instructions  English  Type  P03.6600-010
 Content   by Blum-Novotest 2010 3 1. Safety Rules ................................................................................... 4 2. System Overview .......................................................................... 4 2.1 Description ....................................................................................................... 4 2.2 Display Elements ............................................................................................. 6 2.3 Technical Data................................................................................................ 6 2.4 Area of Work ................................................................................................... 7 2.5 Complete System ........................................................................................... 7 3. Mechanical Installation ............................................................... 8 3.1 Mounting Variants........................................................................................... 9 4. Electrical Connection ................................................................ 12 5. Maintenance .............................................................................. 12 6. Order Numbers ........................................................................... 12 7. Radio Approval .......................................................................... 13   Installation instructions interface IF59-A2    (P03.5900-000.011)  Keys:  CAUTION  Important advice for appliance protection   Advice to secondary literature   Additional advice  Tip     LED shines  LED flashes   Green  Red  Blue  Orange  Violet   Abbreviations: Md Tightening Torque  P03.6600-000.011 306600011_EN.docx 02.05.2011    version: V1A Original operating instructions Subject to technical change without any notice    GN GN GN VT OG BU RD
Safety Rules  4  by Blum-Novotest 2010 1. Safety Rules  CAUTION  Risk of short-circuit Please separate connecting cable resp. plug connection off circuit only.   2. System Overview 2.1 Description The radio receiver is compatible with the BLUM measuring devices TC series (radio probes TC60, TC63-30). The receiver enables wireless communication between the measuring devices and the NC control. Data transfer to the NC control via IF59-A2 interface.   Fig. 2.1  (1a) LED mode  (2)  cable (1b) LED battery  (3)  for mounting screws (1c) LED status  (4)  seal insert + O-Ring  (1d) LED receive     (at horizontal cable outgoing) (1e) LED transmit           90°ModeRC66IF59-A2P03.5900-010-A2341a1b1c1d1e2
 System Overview   by Blum-Novotest 2010 5   Fig. 2.2 Modemax.Ø38min. Ø203042Ø 449,5Ø 3,3Ø 63,2M4373745Ø 6,3
System Overview  6  by Blum-Novotest 2010 2.2 Display Elements  LED  LED colour function MODE (1a)    Standby   Mode TC1 … TC6  Pairing procedure Battery (1b)    Battery o.k.      Battery low Status (1c)      Initial position      Probe deflected Receive (1d)  off  No reception    Reception o.k. Transmit (1e)   Send command Tab. 2.1    2.3  Technical Data  Protection class  IP68 Power supply  12 V DC / 100 mA via IF59-A2 Weight  600 g Signal transmisson  Radio transmission Frequency band:  2,400 – 2,4835 GHz Transmission power  0 dBm Transmitter / receiver range 15 m, see chap. 2.4 Minimum bending radius  60 mm (application: flexible) Max. cable length  50 m Storage temperature  -20 °C ... +70 °C Operating temperature   +5 °C ... +50 °C  Tab. 2.2 ModeModeBU RD GN GN RD OG BU VT GN GN
 System Overview   by Blum-Novotest 2010 7 2.4 Area of Work    TC60 Area of work:  RC66 Transmitter / receiver range:  Fig. 2.3      2.5 Complete System   Fig. 2.4  ⇒ Switch ON/OFF via radio signal ⇒ Signal transmission for TC series   0°0°15°30°45°60°75°15°30°45°60°75°90°16141210615°30°45°60°75°15°30°45°60°75° 90°8240°15°30°45°60°75°90°1614121015°30°45°60°75° 90°8246RC66TC60IF59 - A2Z-NanoAuxTC63-30
Mechanical Installation  8  by Blum-Novotest 2010 3. Mechanical Installation  CAUTION  Risk of short-circuit Damage by chips Never install cables and hoses without protection. Cables and hoses must always be protected against chips (protective hose, protection spring, cover etc.). CAUTION  Risk of short-circuit Damage of the cable by sharp edges Pls. deburr the sharp edges on the cable bushing and mount edge protection! CAUTION  • The system should be placed protected from coolant and chips.  • Distance between probe and receiver:  Pay attention to chap. 2.4 • Keep distance to other radio systems
 Mechanical Installation   by Blum-Novotest 2010 9 3.1 Mounting Variants  Cable outgoing horizontal:    Pollution of the system Mount gasket (9a) and O-ring (9b)         Fig.  3.1    Cable outgoing vertical:                                   Fig.  3.2   4a 4b
Mechanical Installation  10  by Blum-Novotest 2010 Variant 1                                                 Variant 2                    Variant 3 (option)   Fig.  3.3  (4a)  seal insert (4b)  O-Ring  (5)  universal holder (option)    Tightening torque: DIN912 M3x10:   Md =   1,3 Nm (max.) DIN912 M4x10:   Md =   3,0 Nm (max.) DIN912 M6x12:   Md = 10,5 Nm (max.)  Drilling template (scope of delivery)  M3 M4 M64aP03.5600-010.25454bP03.5600-010.080
 Mechanical Installation   by Blum-Novotest 2010 11 Variant 3 Option Universal Holder  Fig.  3.4   Variant 4:   Option Front-Kit        Pls. refer to the appropriate data sheet   1622 M6Ø5,2Klemmschraubeclamping screwDIN913 M4 (2x)Md = 1,5 NmSchwenkbereichswivel range8,5271960°P03.5600-010.080P03.6600-010.250
Electrical Connection  12  by Blum-Novotest 2010 4. Electrical Connection  See installation instructions IF59-A2    5. Maintenance The receiver needs minimum maintenance only. Keep the receiver clean and free from chips.   6. Order Numbers       Radio receiver RC66  - Cable length   L = 10 m   PUR   L = 20 m   PUR   (8 wires)    P03.6600-010-A2-10 P03.6600-010-A2-20            Front-kit P03.6600-010.250            Universal holder  P03.5600-010.080            Heavy Duty Kit Protection spring 1m incl. screwing P03.5600-010.254            Interface IF59-A2  P03.5900-010-A2
 Radio Approval   by Blum-Novotest 2010 13  7. Radio Approval  Area:  Radio Approval:        Regulations: Europe:         0681        EN 300 328 V1.4.1,            EN 301 489-17 V1.2.1,            EN 60950-1:2001 Japan:    R  202WW10568412       “This device has been granted a designation number by Ministry of Internal Affairs and Communications under „Ordinance concerning Technical Regulations Conformity Certification etc. of Specified Radio Equipment (特定無線設備の技術基準適合証明等に関する規則)“ Article 2-1-19.  USA:  FCC ID: ZCQRCA        FCC Part 15 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.   Canada:  IC:9570A-RCA     Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter.  This equipment complies with IC Canada RF radiation exposure limits set forth for an uncontrolled environment as per RSS-102 Issue 4.
  14  by Blum-Novotest 2010 EC Declaration of Incorporation  acc. to the EC Machine Regulations 2006/42/EC in the edition from 17 May.2006     We  hereby  confirm  that  the  subsequently  following  components  are  defined  for  the installation  into  other  machines  and  that  they  are  in  accordance  with  the  following safety requirements of the EC regulations.  Commissioning  is  not  allowed  until  it  is  ascertained  that  the  machines,  in  which  the components are installed, are in accordance with the EC regulations 2006/42/EC.  The relevant technical information is compiled acc. to annex VII part B and, where appropriate, we will send the information concerning the components to the different countries. The industrial property rights of Blum-Novotest GmbH will remain unaffected.   Component name:  P03.6600     Radio receiver Safety requirements 2006/42/EG, Annex I  1.5.1  Applied standards: EC-Regulations:  2004/108/EG   2006/95/EG   1999/5/EG  Applied harmonized standards:  EN61000-6   EN60204-1   EN ISO 12100   EN 300 328   EN 301 489-17   EN 60950-1:2001   Applied national standards:  DIN VDE 0100   DIN VDE 0113  Authorised presentative for technical information:  Blum-Novotest GmbH   Kaufstr. 14   88287 Gruenkraut, Germany
   by Blum-Novotest 2010 15 Service Order  Please fill out completely this repair order and attach it to the system. This will save you and us costs due to time-consuming inquiries and ensures a quick repair.  Blum-Novotest GmbH Kaufstr. 14,  88287 Gruenkraut/Gullen - Germany Tel.  +49 751 6008-0,   Fax. +49 751 6008-156  Company:  Department:  Contact:  Address:  Phone:  Fax:  Email:  Probe Type, Serial No.:  Machine Type, Manufacturer:  Description of Defect:
    focus on productivityfocus on productivity Blum-Novotest GmbH  Kaufstr. 14  88287 Gruenkraut, Germany Tel.:+49 751 6008-0 Fax:+49 751 6008-156 www.blum-novotest.com vk@blum-novotest.com   Hotline:  Vertrieb/sales:  Tel.:+49 751 6008-200 Service LaserControl :   Tel.:+49 751 6008-202 Service Messtaster/probes: Tel.:+49 751 6008-203   Blum-Novotest GmbH Prüftechnik  KK Blum Laser Measuring Technology Willich, Germany  Nagoya, Japan Tel. +49 2154 921970  Tel. +81 568 74-5311  Blum-Novotest Srl  Blum-Novotest Como, Italy  Shanghai, China Tel. +39 031 283 955  Tel. +86 21 52080480  Blum-Novotest Ltd.  Blum Production Metrology Co., Ltd. Birmingham, England  Taichung, Taiwan Tel. +44 1543 257111  Tel. +886 4 2358 3900  Blum Laser Measuring Technology Inc.  Blum Production Metrology Pte. Ltd. Cincinnati, USA  Singapore, Singapore Tel. +1 859 3446789  Tel. +65 62720998  Blum-Novotest Sarl  Blum-Novotest Ltd. Bordeaux, France  Soul, Republic of Korea Tel. +33 55702 0135  Tel. +82 2 2026-1300  Blum-Novotest s.r.o. Kroměříž, Czech Republic Tel. +420 573 330373   Support