1/19Dear Bioland Blood Glucose Monitoring System Owner: Thankyouforchoosingthissystem!Thismanualcontainsimportantinformationyoumustknowaboutthesystem.Pleasereaditthoroughlyandcarefully.ThesystemprovidesNoCodefunctionwhichmeansthatyoudon'tneedtocalibrateyourmetermakingiteasierfortheusertomonitorbloodglucoseathome.IMPORTANT SAFETY INSTRUCTIONS Themeterandlancingdeviceareforsinglepatientuse.Donotsharethemwithanyoneincludingotherfamilymember!Donotuseonmultiplepatients!AlIpartsofthekitareconsideredbiohazardousandcanpotentiallytransmitinfectiousdiseasesevenafteryouhaveperformedcleaninganddisinfection.Changesormodificationsnotexpresslyapprovedbythepartyresponsibleforcompliancecouldvoidtheuser’sauthoritytooperatetheequipment.ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttothefollowingtwoconditions:(1)thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperation.ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates,usesandcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.ThisequipmentcomplieswithFCCradiationexposurelimitssetforthforanuncontrolledenvironment.EndusermustfollowthespecificoperatinginstructionsforsatisfyingRFexposurecompliance.Thistransmittermustnotbeco‐locatedoroperatinginconjunctionwithanyotherantennaortransmitter.TheportabledeviceisdesignedtomeettherequirementsforexposuretoradiowavesestablishedbytheFederalCommunicationsCommission(USA).TheserequirementssetaSARlimitof1.6W/kgaveragedoveronegramoftissue.ThehighestSARvaluereportedunderthisstandardduringproductcertificationforusewhenproperlywornonthebodyIfthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipmentoffandon,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthefollowingmeasures:‐‐Reorientorrelocatethereceivingantenna.‐‐Increasetheseparationbetweentheequipmentandreceiver.‐‐Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiver
2/19isconnected.‐‐Consultthedealeroranexperiencedradio/TVtechnicianforhelp.READ THIS BEFORE USING DANGER‐Misuseofthiselectricaldevicecancauseelectrocution,burns,fireandotherHAZARDS.Basicsafetyprecautionsshouldalwaysbetaken,includingallthoselistedbelow.Closesupervisionisnecessarywhenequipmentisusedby,on,ornearchildren,handicappedpersonsorinvalids.Thefollowingbasicsafetynoticeshouldalwaysbetaken:1.Donotplacethedeviceinliquid,norputitwhereitcouldfallintoliquid.2.Thefollowingbasicsafetynoticeshouldalwaysbetaken.3.Usethedeviceonlyfortheintendedusedescribedinthismanual.4.Donotuseadjunctwhicharenotsuppliedbytheproducer.5.Donotmakethedevicecomeintocontactwithsurfaceswhicharetoohottotouch.6.Donotusethedevicewhereaerosolspraysarebeingused.7.Donotusethedeviceifitisnotworkingproperly,orifithasbeendamaged.8.Readallthemanual,andpracticethetest,andthenusetheproducttotestyourbloodglucose.Doallqualitycontrolchecksasdirectedandconsultwithadiabetesexpert.KEEPTHESEINSTRUCTIONINASAFEPLACE
3/19         Table of Contents BEFOREYOURBEGIN.........................................................................................................................4INTRODUCTIONTOTHESYSTEM.......................................................................................................4IndicationsforUse....................................................................................................................4Caution......................................................................................................................................5Testprinciple.............................................................................................................................5ABOUTALTERNATIVESITETESTING(AST).........................................................................................5CONTENTSOFTHEKITS.....................................................................................................................6BloodGlucoseMeter.................................................................................................................7MeterScreenDisplayMessage.................................................................................................7TestStrip....................................................................................................................................8SETTINGTHEMETERANDDELETINGTHEMEMORY........................................................................8THETWOMEASURINGMODES.......................................................................................................10TESTINGWITHBLOODSAMPLE......................................................................................................10OverviewoftheLancingDevice..............................................................................................10SettingUptheLancingDevice.................................................................................................11Preparingthepuncturesite....................................................................................................12PerformingaBloodGlucoseTest ............................................................................................12ComparingMeterandLaboratoryResults..............................................................................14CONTROLSOLUTIONTEST...............................................................................................................14VIEWINGRESULTSONTHEMETER.................................................................................................15CAREANDSTORAGEFORYOURSYSTEM........................................................................................16CleaningandDisinfection........................................................................................................16METERSPECIFICATION....................................................................................................................17Limitationsofuse:...................................................................................................................17DISPLAYMESSAGE...........................................................................................................................18Problems.................................................................................................................................19
4/19BEFOREYOURBEGINInstallingthebattery1.Openthebatterycoveronthebackofmeter.2.Ifreplacingthebatteries,pleaseremovetheusedbatteries.3.Insert2new(AAA)batterieswithcorrect+/‐direction.4.Closethebatterycover.EnvironmentProtection–Wasteelectricalproductsshouldnotbedisposedofwithhouseholdwaste.Pleaserecyclewherefacilitiesexist.CheckwithyourlocalAuthorityorretailerforrecyclingadvice.INTRODUCTIONTOTHESYSTEMIndicationsforUseTheBloodGlucoseMonitoringSystemisintendedtobeusedforthequantitativemeasurementofglucose(sugar)infreshcapillarywholebloodsamplesdrawnfromthefingertip.TheBloodGlucoseMonitoringSystemisintendedtobeusedbyasinglepatientandshouldnotbeshared.TheBloodGlucoseMonitoringSystemisintendedforself‐testingoutsidethebody(invitrodiagnosticuse)bypeoplewithdiabetesathomeasanaidtomonitortheeffectivenessofdiabetescontrol.TheBloodGlucoseMonitoringSystemisnottobeusedforthediagnosisoforscreeningofdiabetes,orforneonataluse.TheTestStripsareforusewiththeBloodGlucoseMetertoquantitativelymeasureglucosedrawnfromthefingertips.
5/19Caution Thesystemisintendedforuseoutsidethebody(invitrodiagnosticuse).Itisforsingle‐patientuse.Itshouldbeusedonlyfortestingglucose(sugar)andonlywithfreshcapillarywholebloodsamplestakenfromthefingerandthealternativesitesincludingthepalm,theforearm,theupperarm,thecalfandthethigh.Thesystemisintendedforuseathome.Itshouldnotbeusedforthediagnosisofdiabetesorforthetestingofnewborns. TheSystemistobeusedbyasinglepersonandshouldnotbeshared. TheSystemisintendedforself‐testingoutsidethebody(invitrodiagnosticuse)bypeoplewithdiabetesathomeasanaidtomonitortheeffectivenessofdiabetescontrol.Alternativesitetestingshouldbedoneonlyduringsteady–statetimes(whenglucoseisnotchangingrapidly). The“Bioland”TestStripsareforusewiththeBloodGlucoseMetertoquantitativelymeasureglucoseinfreshcapillarywholebloodsamplesdrawnfromthefingertips,palm,forearm,upperarm,calfandthigh. TheBiolandcontrolsolutionsisintendedforusewiththeSystem,tocheckthattheglucosemeterandteststripsareworkingproperlyandthatyouaredoingthetestcorrectly.Thesesolutionscontainaknownrangeofglucose,asindicatedonthestripsvialbottles. Thisdeviceisnotintendedforuseinhealthcareorassisted‐usesettingssuchashospitals,physician’soffices,orlong‐termcarefacilitiesbecauseithasnotbeendeterminedtobesafeandeffectiveforuseinthesesettings,includingforroutineassistedtestingoraspartofglycemiccontrolprocedures. UseofthisdeviceonmultiplepatientsmayleadtotransmissionofHumanImmunodeficiencyVirus(HIV),HepatitisCVirus(HCV),HepatitisBVirus(HBV),orotherbloodbornepathogens.ASTinthissystemcanbeusedonlyduringsteady‐statebloodglucoseconditionsdescribedinthesectionof“AboutAST”.TestprincipleThetestisbasedonthemeasurementofelectricalcurrentgeneratedbythereactionofglucosewiththereagentofthestrip.Themetermeasuresthecurrentanddisplaysthecorrespondingbloodglucoselevel.Thestrengthofthecurrentproducedbythereactiondependsontheamountofglucoseinthebloodsample. ABOUTALTERNATIVESITETESTING(AST)Important.TherearelimitationsfordoingAST.PleaseconsultyourhealthcareprofessionalbeforeyoudoAST.
6/19WhatisAST?Alternativesitetesting(AST)meansthatpeopleusepartsofthebodyotherthanthefingertipstochecktheirbloodglucoselevels.Thissystemallowsyoutotestonthepalm,theforearm,theupperarm,thecalf,orthethighwiththeequivalentresultstofingertipstesting.What’stheadvantage?Fingertipsfeelpainmorereadilybecausetheyarefullofnerveendings(receptors).Atotherbodysites,sincenerveendingsarenotsocondensed,youwillnotfeelasmuchpainasatthefingertip.WhentouseAST?Food,medication,illness,stressandexercisecanaffectbloodglucoselevels.Capillarybloodatfingertipreflectsthesechangesfasterthancapillarybloodatothersites.Thereforewhentestingbloodglucoseduringorimmediatelyaftermeal,physicalexercise,oranyotherevent,takeabloodsamplefromyourfingeronly.YoudoASTonlyinthefollowinginstances: Inapre‐mealorfastingstate(morethan2hourssincethelastmeal). Twohoursormoreaftertakinginsulin. Twohoursormoreafterexercising.NOTE: Alternativesitetesting(AST)shouldnotbeusedtocalibratecontinuousglucosemonitoringsystems(CGMs). Resultsfromalternativesitetestingshouldnotbeusedininsulindosescalculations.DoNOTuseASTif: Youthinkyourbloodglucoseislow. Youareunawareofhypoglycemia. Youaretestingforhyperglycemia. YourASTresultsdonotmatchthewayyoufeel. Yourroutineglucoseresultsareoftenfluctuating.CONTENTSOFTHEKITS AMeter Owner’sManual TestStrips(Optional) LancingDevice SterileLancet(Optional) ControlSolution(Optional)NOTE: TheLancingDevicecanbeusedforseveraltimeshoweverthelancetshouldbechangedaftereachuse. Sterilelancetandcontrolsolutionarenotincludedinthestandardkit.
7/19 Therearethreelevelsforthecontrolsolutions:low,normalandhighavailable,pleasecontacttheplaceofpurchaseformoreinformation. Ifanyitemsaremissingfromyourkitoropenedpriortouse,pleasecontactlocalcustomerservicesorplaceofpurchaseforassistance.BloodGlucoseMeter1.STRIPPORT:Whereyouinserttheteststrip.Themeterwillturnonautomatically2.STRIPEJECTOR:Slideforwardtoejecttheteststripaftertest3.LCDDISPLAY:Itguidesyouthroughthetestusingsymbolsandsimplemessages4."M"BUTTON:Itisusedtoturnonthemeterenterthememorymode5."S"BUTTON:ItisusedtosetupthemeterMeterScreenDisplayMessage1) BLOODDROPSYMBOL:Flasheswhenitisreadytoapplythebloodsample2) TESTSTRIPSSYMBOL:Appearswhenthemeteristurnedon3) LOWBATTERYSYMBOL:Appearswhenthebatterypowerislow4) MEASUREMENTUNIT:Appearswiththetestresultinmg/Mlormmol/L5) TRANSMISSIONSTATE:Appearswhenthedatetransmitting,transmissionsuccessandtransmissionfail6) MEMORYSYMBOL:Appearswhenyoureviewthememory7) KETONEWARNING:Appearswhenyourresult≧13.3mmol/L(240mg/dl)8) TIME9) DATE10) TESTRESULTAREA:Displaysglucoseresults11) GSMSignalStrength
8/19TestStripEachstripcanbeusedonlyonce.Theteststripconsistsofthefollowingparts:1‐AbsorbentholeApplyadropofbloodhere.Thebloodwillbedrawninautomatically.2‐ConfirmationwindowThisiswhereyouconfirmifenoughbloodhasbeendrawnintotheabsorbentholeofthestrip.3‐TeststriphandleHoldthisparttoinserttheteststripintotheslot.4‐ContactbarsInsertthisendoftheteststripintothemeter.Pushitinfirmlyuntilitwillgonofurther.Attention!TestresultsmightbewrongifthecontactBarisnotfullyinsertedintothetestslot.Thefrontsideoftheteststripshouldfaceupwheninsertingtheteststrip.SETTINGTHEMETERANDDELETINGTHEMEMORY 1.Settingthedateandtime1.1SettingtheYearPressandHold“S”buttonfor3seconds,untilthelasttwodigitsoftheyearwillflashonthescreen(forexample,“14”equals2014).Press“M”buttonuntilthecorrectyearappears.Press“S”.1.2SettingthemonthWiththemonthflashing,press“M”untilthecorrectmonthappears.Press“S”.1.3SettingthedayWiththedayflashing,Press“M”untilthecorrectdayappears.Press“S”.1.4SettingthehourWiththehourflashing,Press“M”untilthecorrecthourappears.PressS“.
9/191.5SettingtheminuteWiththeminuteflashing,Press“M”untilthecorrectminuteappears.Press“S”.2.DeletingtheMemoryPress“S”then” ”and“dEL”willdisplaywithflashing“no”or“yES”.ORPress“M”until“yES”flashing,Pressthe“S”buttontodeleteallmemory.Themeterthendisplays“OK”,whichmeansthatthememoryisdeleted.Ifyoudon’twanttodeletethememory,when“no”flashing,pressthe“S”buttontoskipthisstep.3.SettingtheAlarmYoumaysetupanyorallofthealarms(1~4).Whenthemeterisdisplaying“On”or“OFF”,pressthe“M”buttontoturnonorturnoffthefirstalarm.Pressthe“S”buttontoselect“On”,thentosetthehour.Whenthehourisflashing,pressthe“M”buttontoaddanhour.Whenthecorrecthourisset,pressthe“S”buttontoconfirmandgotosettheminutes.Pressthe“M”buttontoaddoneminute.Whenthecorrectminuteisset,pressthe“S”buttontoconfirmandgotothenextalarmsetting.Ifyouwanttoturnoffanalarm,pressthe“S”buttontofindtherightalarmnumberandpressthe“M”buttontochangefrom“On”to“OFF”.NOTE: Thedate,time,unitandmemorydeletioncanONLYbesetinthesettingmode. Whenthemeterisinsettingmode,ifnobuttonispressedwithin3minutes,themeterwillturnoff.
10/19THETWOMEASURINGMODESThemeterprovidesyouwithtwomodesformeasuring,GeneralandCTL.TheCTLmodeshouldbeusedwhenacontrolsolutionisbeingtested.Seethetablebelow.ModesUsewhenGeneraltest(notdisplay)AnytimeofdaywithoutregardtotimesincelastmealCTLTestingwiththecontrolsolutionYoucanswitchbetweeneachmodeby:1.Startwiththemeterturnedoff.Insertateststriptoturnonthemeter,thescreenwilldisplayaflashingblooddrop. 2.PressMtoselectGeneralorCTLmode.TESTINGWITHBLOODSAMPLECAUTION:Toreducethechancesofinfection: Chooseaclean,dryworksurface. Neversharealancingdeviceandlancetwithanotherperson. Alwaysuseanewandsterilelancet.Lancetsareforsingleuseonly. Alwaysuseanewteststrip.Teststripareforsingleuseonly. Avoidgettinglotion,oils,dirtordebrisinoronthelancetandlancingdevice.Note:Beforetesting,pleasereadthefollowingstepsthoroughlyandcarefully,pleaserelaxanddotheteststepbystep.Simplifyingorchangingthetestproceduremayproduceinaccurateresults.OverviewoftheLancingDeviceA.DeviceCapB.HandleC.NeedleCapD.NeedleHolderE.DeviceBodyF.ConnectingCollarG.AdjustabletipH.ReleaseButton
11/19I.EjectionButtonJ.DevicecontrolcapOnthelancetsandthelancingdevice.Ifyourlancingdevicediffersfromtheoneshownhere,pleaserefertothemanufacturer’smanualtoensureproperusage.NOTE:Toreducethechanceofinfection:●Neversharealancetorthelancingdevice.●Alwaysuseanew,sterilelancet.Lancetsareforsingleuseonly.●Avoidgenghandloon,oils,dirt,ordebriswhenhandlingthelancets.SettingUptheLancingDevice1.Screwthelancingdevicecapoff.Insertaneedleintothelancetholderandpushdownfirmlyuntilitisfullyinplace.2.Screwtheneedlecapandplaceitinappropriatelocationtouseagainafterfinishblood‐taking.3.Replacethelancingdevicecap.Turnthecapuntilitissnugbutnottootight.AndthenAdjusttheadjustabletiptoproperlevel.NOTE:Theadjustabletipoffers5levelsofskinpenetration.Twisttheadjustabletiptotheproperlevel:1‐2levelforsoftorthinskin3levelforaverageskin4‐5levelforthickorcallousedskin4.Pullthedevicecontrolcapuntilitclicks.Ifnotclicks,checktheneedleisinstalledappropriately.5.Aimingatthesterilizedpartforblood‐taking,pressthereleasekeytofinishblood‐taking.6.Screwthedevicecap.Pushtheexposedneedleintotheneedlecap,andthenpushtheejectionbuttontodiscardtheusedneedlein
12/19appropriatecontainer.Coverthedevicecapatlast.PreparingthepuncturesiteStimulatingbloodperfusionbyrubbingthepuncturesitepriortobloodextractionhasasignificantinfluenceontheglucosevalueobtained.Bloodfromasitethathasnotbeenrubbedexhibitsameasurablydifferentglucoseconcentrationthanbloodfromthefinger.Whenthepuncturesitewasrubbedpriortobloodextraction,thedifferencewassignificantlyreduced.Pleasefollowthesuggestionsbelowbeforeobtainingadropofblood: Rubthepuncturesiteforabout20secondsbeforepenetration. Selectthepuncturesiteeitheratthefingertipsoranotherbodypart(pleaseseesection“AlternativeSiteTesting ”(AST)onhowtoselecttheappropriatesites). Cleanthepuncturesiteusingcottonmoistenedwith70%alcoholandletitairdry.FingertiptestingHoldthelancingdevicefirmlyagainstthesideofyourfinger.Pressthereleasekey.Youwillhearaclick,indicatingthatthepunctureiscomplete.NOTE: Chooseadifferentspoteachtimeyoutest.Repeatedpuncturesatthesamespotmaycausesorenessandcalluses. PleaseconsultyourhealthcareprofessionalbeforeyoubeginAST. Itisrecommendedtodiscardthefirstdropofbloodasitmightcontaintissuefluid,whichmayaffectthetestresult.PerformingaBloodGlucoseTestStep1.Washhandswithsoapandwarmwater.Step2.Removeateststripfromitsvial.Withclean,dryhands,youmaytouchtheteststripanywhereonitssurface.Donotbend,cutormodifytheteststripsinanyway.Removetheteststripfromthevialanduseitinstantly.Step3.Inserttheteststripintothemeter'stestportandthemeteristurnedon.Thetimeanddateappearsonthescreen.NOTE:Besuretouse“Bioland”teststrips,otherteststripsmaynotproduceaccurateresults.
13/19Step4Whentheblooddropsymbolflashesonthescreen,youmayselecttheappropriatemeasurementmode,forselectingthemeasurementmodeofControl(CTL)orGeneral,pleaserefertothe“THETWOMEASURINGMODES”section.Step5Applyyourbloodtotheabsorbentholeoftheteststrip.Step6Assoonasenoughbloodhasfilledtheconfirmationwindowoftheteststrip,youwillhearabeeplettingyouknowthetesthasbegun.Acountdownof5secondsstarts.Note:makesuretheconfirmationwindowoftheTestStripiscompletelyfilledwithyourbloodsample.Step7Yourbloodglucoselevel,alongdateandtimeappearsonthedisplay.Bloodglucoseresultsareautomaticallystoredinthememory. When GSM connected, GSMsymbolflashing,andthetestresultsdatawilltransmissiontotheCloudsystemautomatically.NOTE:Theresultsobtainedfromthismeterareplasma‐calibrated.Thishelpsyouandyourphysicianorotherqualifiedhealthcareprovidertocompareyourmeterresultswithlaboratorytests.Referencetotheinstructionsgivenbyyourphysicianorotherqualifiedhealthcareprovider,donotdeviatefromtheseinstructionsonthebasisoftheresultwithoutfirstconsultingyourphysician.Step8Ejecttheusedteststripandremovethelancet.Toejecttheteststrip,pointthestripatadisposalcontainerforsharpobjects.Themeterwillswitchitselfoffautomaticallyaftertheteststripisejected.Pleasewashhandsthoroughlywithsoapandwaterafterhandlingthemeter,lancingdevice,orteststrips.Referencevalue:TimeofdayNormalplasmaglucoserangforpeoplewithout
14/19Beforebreakfast(fasting)<100mg/dLTwohoursaftermeals<140mg/dLSource:AmericanDiabetesAssociation.StandardsofMedicalCareinDiabetes‐2012.DiabetesCare2012,35(Suppl.1)S11‐S63.Pleaseworkwithyourdoctortodetermineatargetrangethatworksbestforyou.ComparingMeterandLaboratoryResultsThemeterprovidesyouwithwholebloodequivalentresults.Theresultyouobtainfromyourmetermaydiffersomewhatfromyourlaboratoryresultduetonormalvariation.Meterresultscanbeaffectedbyfactorsandconditionsthatdonotaffectlaboratoryresultsinthesameway.Tomakeanaccuratecomparisonbetweenmeterandlaboratoryresults,followtheguidelinesbelow.Beforegoingtothelab:■Doacontrolsoluontesttomakesurethatthemeterisworkingproperly.■Fastforatleasteighthoursandthendocomparisontests,ifpossible.■Takeyourmeterwithyoutothelab.Whilestayingatthelab:Makesurethatthesamplesforbothtestsaretakenandtestedwithin15minutesofeachother.■Washyourhandsandthenobtainabloodsample■Neveruseyourmeterwithbloodthathasbeencollectedinagraytoptesttube.■Usefreshcapillarybloodonly.CONTROLSOLUTIONTESTMaterialneeded:●GlucoseMeter●Teststrips●ControlsoluonWhentodoacontrolsolutiontest:◆Whenyoususpectthatthemeterorteststripsarenotworkingproperly.◆Ifyourbloodglucosetestresultsarenotconsistentwithhowyoufeel.◆Aftertheteststripsareexposedtoextremeconditions.◆Afterdroppingthemeter.Thecontrolsolutionistocheckthatthemeterandtheteststripscanworktogetherasasystemandworkcorrectly.Step1Inserttheteststriptoturnonthemeter.Inserttheteststripintothemeter.Waitforthemetertodisplaythedropsymbol.Step2
15/19Youmaypress“M”buttontoselectCTLmode,forselectingtheCTLmode,pleaserefertothe“THETWOMEASURINGMODES”section.Step3ApplythecontrolsolutionShakethecontrolsolutionvialthoroughlybeforeuse.Squeezeoutadropandwipeitoff,thensqueezeanotherdropandplaceitonthetipofthevialcap.Holdthemetertomovetheabsorbentholeofteststripsoittouchesthedrop.Oncetheconfirmationwindowfillscompletely,themeterwillbegincountingdown.Toavoidcontaminatingthecontrolsolution,donotdirectlyapplycontrolsolutionontoastrip.Step4Theresultofthecontrolsolutionstestappearsonthedisplay.TheresultwillnotbestoredunderCTLmode.Theresultofthecontrolsolutionstestshouldbewithintherangeprintedontheteststripviallabel.Ifthetestresultsfallsoutsidethespecifiedrangeprintedonteststripviallabel,repeatthetest.Resultsfallingoutsidethespecifiedrangemaybecausedby:■Errorinperformingthetest■ExpiredorcontaminatedControlSolution■ExpiredorcontaminatedTestStrip■MalfunconofyourMeterIfyoucontinuetogetcontrolsolutiontestresultsthatfalloutsideoftherangeprintedonthevial,thesystemmaynotbeworkingproperly,Donotusethemeter.PleasecontactyourcustomersupportimmediatelyNOTE:Donotusetheexpiredcontrolsolution.VIEWINGRESULTSONTHEMETERYourmeterstoresthe500mostrecentbloodglucosetestresultswithdatesandtimes.Italsoprovides7‐,14‐,21‐,28‐,60‐and90‐dayaveragesofyourbloodglucosetestresults.Note:Thecontrolsolutionreadingsarenotincludedintheaverageofyourresults.RecallingtheStoredTestResults1.Startwiththemeteroff,pressthe“M”buttontoturnonthemeter.The“”symbolwillflashwiththetimeanddatedisplayedonthescreen.2.Press“M”again,themostrecenttestresultswithdateandtimewilldisplay.Press“M”oncemoreandthenextmostrecenttestresultswillappear.Eachtimeyoupressandrelease“M”,themeterwillrecalluptoyourlast500testresultsinorder.Pressthe“S”toturnoffthemeter.Whenthememoryisfull,theoldestresultisdroppedandthenewestresultis
16/19added.ReadingtheAverageofBloodGlucoseResultsWhenthemeterisoff,pressandholdthe“M”buttonuntiltheDAYAVGflashing,releasebuttonthen7‐dayaverageresultsappearwith“n024”(means24recordstobeaveraged)onthescreen.Pressthe“M”buttontoreviewthe14‐,21‐,28‐,60‐and90‐daygeneralaverages.Pressthe“S”buttontoturnoffthemeter.Note:Thecontrolsolutionreadingsarenotincludedintheaverageofyourresults.CAREANDSTORAGEFORYOURSYSTEM◆Handlethemeterwithcare.Droppingorthrowingthemetermaycausedamagetothedevice.◆Don'texposetheBloodGlucoseMonitoringSystem,Teststrip,andControlSolution,toextremeconditions,suchashighhumidity,heat,freezingcoldordust.Thestorageconditionsfortheteststripsare39℉~86℉,Humidity<80%RH.Storageconditionsforthemeterare‐40℉~131℉,Humidity<80%RH.◆AlwayswashyourhandswithsoapandwaterandrinseanddrycompletelybeforehandlingtheBloodGlucoseMonitoringsystemandTeststrip.◆UseCaviWipes(seebelow)tocleantheBloodGlucoseMonitoringSystem.◆Discardtheusedlancetintoacontainerforsharpobjects.CleaningandDisinfectionThecleaninganddisinfectionisabsolutelynecessaryforthetestprocedure,becausecleaningcaninsurethemeterworkswell(forexample,displaywillbecleartoseeaftercleaning);anddisinfectioncanavoidtheinfectiontoyouortotheotherpeople,andthecross‐infection.Westronglywarnthatthedeviceshouldbecleanedanddisinfectedfollowinguseoneverypatient.Andwesuggestyouusethefollowingproduct:CaviWipes(EPAregistrationnumber:46781‐8).Youcanpurchasethisproductaccordingtothefollowinginformation:visitthewebsite:www.metrex.comorcontactMetrexat800‐841‐1428forproductortechnicalinformation.CaviWipesarealsoavailableatwww.amazon.comorviaaGooglesearch.Themeterforsingle‐patientuseandthelancingdevicesmaybecleaned5‐6timesperday(Test5‐6timeseveryday),sothemeterwillbecleanedanddisinfectabout11000cyclesthatincludecleaningsplusdisinfections(1cycle=1cleaning+1disinfection)duringits5yearslifecycle.1.Beforethetest,theusershouldcleanandwashhands.Ifyouareacaregiver,(notthepatient),pleaseusedisposablegloves.2.Aftertest,takeonewipetocleanthemeter’shousing,buttons,lens,mark,usbcoverandsupportblock,includingitsfrontandbackfor10secondsforcleaninguntilthereisnosoilonthesurface.Thendisinfectthemeter’shousing,buttons,lens,mark,usbcoverandsupportblockuseanotherwipefor2min,keepthesurfacewetfor2min.3.Takeofftheglove;discardcarefullyaccordingtoyourhealth‐careprovider’sinstruction.
17/19Note:1.Eachdisinfectionsteprequiresapre‐cleaningstep.2.Ifthemeterisbeingoperatedbyasecondpersonwhoisprovidingtestingassistancetotheuser,themeterandlancingdeviceshallbecleanedanddisinfectedfirst.3.Theusersshouldwashhandsthoroughlywithsoapandwaterafterhandlingthemeter,lancingdevice,orteststrips.METERSPECIFICATIONModelG‐427G(with“Bioland”teststripandcontrolsolution)Machinesize104mm(L)×54mm(W)×24mm(H)Weight64g(excludingbattery)MeasuringmethodAmperometrictechnologyusingglucoseoxidaseMeasuringrange20mg/dL~600mg/dLBloodSourceFreshcapillarywholebloodBloodVolumeAround0.7uLMemory500bloodglucosetestsDisplayLCDdisplaywithbacklightPowersourceDC3.7V(Litium‐ionbattery)BatteryLifeApprox.400charge‐discharecyclesOperatingconditions50℉~104℉,Humidity:25%~80%RH860hPa~1060hPaStorageCondition(system:meterandteststrips)39℉~104℉andbelow80%relativehumidity700hPa~1060hPaStorageCondition(meter)‐40℉~131℉,Humidity<80%RH,700hPa~1060hPaUselifeFiveyearsLimitationsofuse:※ThebloodMonitoringSystemisnotintendedforuseonneonates.※ThebloodMonitoringSystemisnotintendedforuseonarteryblood,neonates’serumandplasma.※TheBloodGlucoseMetershouldbeusedwith“Bioland”teststrip.※Thesystemcanbeuseduptoanaltudeof10744feet.※Thefollowingsubstancesatlevelsgreaterthannormalortherapeuclevelsmaycausesignificantinterference(affecttheresultbygreaterthan10%)resultinginaninaccurateresult:ascorbicacid,uricacid,hemoglobin,acetaminophen,Dopamine,L‐dopa,L‐dopaandTolbutamideetc.Thesesub‐stancesdonotaffecttestresultsinnormalconcentrationbutmayaffecttestresultsinhighconcentration.Donotusehaemolysissample,icterussampleorhighlipemiasamples.
18/19※Thefollowingcompounds,whendeterminedtoinexcessoftheirlimitaon,mayproduceinaccurateresults:Compound LimitationAscorbicacid >2mg/dLUricacid>10mg/dLAcetaminophen >5mg/dLBilirubin>15mg/dLDopamine>0.03mg/dLL‐dopa>0.45mg/dLMethyldopa>0.75mg/dLTolbutamide >24mg/dLTriglycerides >2000mg/dLHemoglobin >250mg/dL※Paentsundergoingoxygentherapymayyieldfalselylowerresults.※Notforuseforpatientsinahyperglycemic‐hyperosmolarstate,withorwithoutketosis.※Notforuseoncricallyillpaents.※Nottobeusedforpaentswhoaredehydrated,hypertensive,hypotensiveorinshock.※Verylow(lessthan20%)orveryhigh(morethan60%)redbloodcellcount(hematocrit)canleadtoincorrecttestresults.Ifyoudonotknowyourhemarocritlevel,pleaseconsultyourhealthcareprovider.DISPLAYMESSAGEMESSAGEWHATITMEANSACTIONBloodglucoselevelislowerthan20mg/dl(1.1mmol/L)Themessageindicatesverylowbloodsugar.Youshouldconsultwithyourhealthcareprofessional.Bloodglucoselevelishigherthan600mg/dl(33.3mmol/L)Thisindicatesseverhyperglycemia(highbloodglucose).Youshouldseekimme‐diatemedicalassistance.MeterisreadytotestcontrolsolutionundertheCTLstate.Pleaseplaceadropofcontrolsolutionontothetestwellofteststrip.Batterypowerislow.Pleasechangethebattery.MESSAGEWHATITMEANSACTIONUseausedteststripPleaseuseanewstripandre‐test
19/19ErrormassageindicatesthatyoumayremovethestripafeterapplyingbloodtotheabsorbentholeTryagainwithanewteststripProblemwiththemeterRe‐testwithanewteststrip.Iftheproblemisstillunsolved,pleasecallthecustomercarelineforhelp.Environmentaltemperatureislowerthan50℉~104℉Pleasetestatanenvironmentaltemperaturewithin50℉~104℉operationrangeProblemsProblemsCausesSolutionsDisplayremainsblankaftertheteststriphasbeeninsertedintotheMeter.1.Batterypoweristoolowforuse.2.ToomuchtimehaspassedbetweeninsertingtheTestStripandperfor‐mingthetest.3.TestStriphasnotbeenfullyinsertedintotheMeter.1.Rechargethebatterybeforeuse.3.ReinserttheTestStripintotheMeter.4.ReinserttheTestStripintotheMeter.TestresultsareinconsistentorControlSolutiontestresultsarenotwithinthespecifiedrange.1.NotenoughsampleintheTestStrip.2.TestStriporControlSolutionhasexpired.3.TestStriphasbeendamagedduetoheatorhumiditysothatsamplecannotbeappliedorthespeedofapplyingsampleistooslow.4.Systemisnotper‐formingduetotheenvironmentbeingaboveorbelowroomtemperature.1.Redotestwithnewteststripandmakesurethatenoughsamplehasbeenadded.2.Redotestwithnewteststrip.3.PerformaControlSolutiontestusinganewTest Strip.Ifresultsarestilloutofrange,replacewithnewvialofTestStrips.4.BringSystemtoaroomtemperatureenvironmentandwaitapproximately30minutesbeforeper‐forminganewtest.TheMeterco‐untdowndidnotstart.TestStriphasnotbeeninsertedcorrectly.UseanewTestStripandredothetest.   Bioland Technology LTD. No. A6B7 (Block G) ShangRong Industrial Zone No. 5 Baolong Road, Baolong Community Longgang District 518116, Shenzhen, Guangdong PEOPLE’S REPUBLIC OF CHINA