CADENACIO  User  Manual  www.bioinsec.com 2    Contents  1. Before You Begin .................................................................................................................... 5 1. Safety Precautions / Emergency Measures ........................................................................ 5 2.  Proper Way to Input Fingerprint ......................................................................................... 7 3.  Product Introduction .......................................................................................................... 7 4. Product Diagram ............................................................................................................... 9 5.  Icon Information .............................................................................................................. 10 6.  Product Features ............................................................................................................ 11 7.  Terminal Menu ................................................................................................................ 14 2. User Management(Registration/Edit/Delete) Menu ................................................................. 19 1.  Administrator Password Registration ............................................................................... 19 2.  Enroll User ...................................................................................................................... 20 ①  Fingerprint Registration ............................................................................................... 20 ②  Card Registration ........................................................................................................ 21 ③ Password Registration ................................................................................................. 22 ④  When setting with Fingerprint or Card ........................................................................ 22 3.  Edit User......................................................................................................................... 23 4.  Delete User .................................................................................................................... 24 3. Mode Setup (Access Control/Time & Attendance Setup/Meals Setup) ............................ 24 1.  Access Control Setup (Access Control) ............................................................................ 24 2.  Attendance Management Setup ....................................................................................... 25 < Reporting Time Auto Setup> ............................................................................................. 26 3.  Meals Mode ................................................................................................................... 27 4.  Prevention of Unnecessary Events in Attendance / Meal Counting Mode........................... 28 4. Access Door Setup ................................................................................................................ 29 1.  Use of I/O MAN ............................................................................................................. 29 2.  Link to Speed Gate (Change of Door Opening Time) ........................................................ 29 5. Network ................................................................................................................................ 30 1.  Terminal ID ..................................................................................................................... 30 2.  TCP/IP Network Connection ........................................................................................... 30 3.  RS485 Network Connection ............................................................................................ 32 6. Camera Setup ...................................................................................................................... 33
CADENACIO  User  Manual  www.bioinsec.com 3  1.  Camera Operation Mode Setup ...................................................................................... 33 2.  Viewing with Camera ...................................................................................................... 34 7. Display ................................................................................................................................. 35 1.  Lighting Hours ................................................................................................................ 35 2.  Contrast ......................................................................................................................... 36 3.  Brightness ...................................................................................................................... 36 4.  Black / White Mode (Daylight Mode) ............................................................................. 37 5.  Set Time ......................................................................................................................... 37 6.  Set Date ......................................................................................................................... 38 7.  Language ....................................................................................................................... 39 8. SD Memory Backup & Restore ........................................................................................... 39 1.  SD Memory Function ..................................................................................................... 40 2.  Auto Log Data Backup Function ..................................................................................... 40 3.  Import from SD memory ................................................................................................ 40 4.  Export to SD Memory .................................................................................................... 41 5.  How to Update Firmware ............................................................................................... 42 9. Initialization ......................................................................................................................... 42 10. Q&A ..................................................................................................................................... 43 1.  I cannot view the LCD from outdoors. ............................................................................ 44 2.  Card is not authorized when using Serial PC Device. ...................................................... 44 3.  I want to know the Card Number. .................................................................................. 45 4.  The fingerprint registered on the USB Fingerprint Device ............................................... 45 is not properly recognized. .................................................................................................... 45 5.  The LCD screen keeps turning off and giving out a ‘beep beep’ sound. ......................... 46
CADENACIO  User  Manual  www.bioinsec.com 4  FCC Information to User This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is con-nected. • Consult the dealer or an experienced radio/TV technician for help.  Caution Modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.  FCC Compliance Information : This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation
CADENACIO  User  Manual  www.bioinsec.com 5     Revision History Version  Date  Description Ver 1.0.0  April 26, 2010  Release Cadenacio          1. Before You Begin 1. Safety Precautions / Emergency Measures  Do not turn on the power when water or foreign substances went into the power supply.  Do not touch the power with wet hands. Please use the power on the specification. Do not install in places where electricity (voltage/current) flows or leaks. Please do not install in places where there is oil smoke, flammability, explosives, humidity, lots of dust, and places where water(rainwater) splashes.  Do not place candle light or cigarette light on top of the product, or install the product near heating equipment.   Please take care when a customer personally installs or relocates the product. Do not install in places where there is a lot of direct sunlight or moisture, dust or soot. There is the cause of electric leakage or electric shock, and it may become the cause of malfunction.     Regarding the location of installation, it is a general rule to install the product indoors. In case of inevitably installing the product outdoors, please make and use a supportive box that can protect the device.   For device installation and wiring, please refer to the attached wiring diagram.  Please install the device and register the administrator ID and administrator fingerprint.   Please do not put foreign substances such as water, benzene, paint thinner, alcohol, adhesive substance, other pins and needles, and other metal substances.    Be careful not to let fluids such as water, beverage, and chemicals inside the terminal.
CADENACIO  User  Manual  www.bioinsec.com 6  Do not drop the product or give strong impact. When cleaning, do not spray water on the product and wipe with soft cloth or washcloth.  Do not disassemble, repair or remodel the product on one’s own accord.  ※ We shall not be held liable for accidents and damages arising from not using the product as directed in the user manual.          Things you must do before installing the product for the first time 1-1.   Please change the system password. There may be security problems because the password is temporarily set to ‘1111’ when CADENACI is shipped out from the plant.  1-2.   Please connect the cable when the power is not authorized.   When fingerprint is not properly recognized  -  Please try again after removing moisture or foreign substances from the user’s fingerprint.   -  When entering fingerprint, enter the fingerprint by pressing the tip of the finger onto the sensor.   -  Please be careful not to move the finger during fingerprint recognition. -  When the fingerprint image is not clear, please adjust the exposure value of the fingerprint sensor.    When Cadenacio does not function properly -  Try again after initializing Cadenacio by pressing the Reset switch. -  If the problem is not solved with the method above, please make an inquiry to our customer service center.
CADENACIO  User  Manual  www.bioinsec.com 7  2.  Proper Way to Input Fingerprint    Fingerprint Input Location               Fingerprint Contact Method           3. Product Introduction  BIOINSEC’s CADENACIO model is a fingerprint recognition access control system applicable to all areas requiring personal authentication such as access control, attendance management, membership management, and academic affairs management. This product recognizes a person and saves the image at the point of recognition using a fingerprint. By doing so, it solves problems such as piracy due to illegal use and loss by an agent, which occur in existing terminals using ID cards or keypads.   A fingerprint is characterized by inalterability and uniqueness. It is the area most widely used in biometrics due to its inexpensive price. CADENACIO is a product using BIOINSEC’s world renowned optical fingerprint sensor. It boasts excellent performance due to its durability and stability.
CADENACIO  User  Manual  www.bioinsec.com 8  CADENACIO has already been recognized for its reliability by being supplied to many places such as government offices, large corporations, and academic institutes.  CADENACIO  has improved its performance by implementing camera function with a camera directly built into the mainboard. Through this, it has added video storage function upon recognition success or failure, and remote visitor image identification function. In addition to this, it has allowed the user to personally send one’s WAV file to the terminal so it can generate a desired voice by applying AC97 voice codec for high quality voice support.    CADENACIO has its own door open relay, and I/O MAN(controller) can be added in places requiring higher security. It offers the optimum solution for access control using various I/O of IOMAN.  The CPU speed of the terminal is a very fast 400 MHz, and through this, high speed calculation and authentication speed was maximized.  Furthermore, by modulizing the LAN card and camera that may cause problems, user convenience was maximized to enable the use of the terminal body just by replacing the card when a problem occurs.  On top of that, storage capability was enhanced to enable the loading of 1~2GByte Micro SD Memory Card (T Flash) for storing user videos when the terminal is used as a single unit due to disconnection with a network.    Using various functions like this, it can be used for multi-purpose in places requiring personal authentification such as time & attendance management and academic affairs management as well as being able to conduct access control in highly secure areas.
CADENACIO  User  Manual  www.bioinsec.com 9  4. Product Diagram                    Speaker Voice GuideFingerprint Built-in Camera LCD Proximity Sensor MicrophonCall ButtonKeypad Keypad -Up/Down Arrow Key Menu Clear ButtonEnter Reset Hole  Mifare(13.56KHz)
CADENACIO  User  Manual  www.bioinsec.com 10  5. Icon Information   Normal Network icon appearing when communication with the server is normal  Icon showing when communication with the server is cut off  DHCP mode setting in progress  No Camera Icon  Camera Off  Camera Auto/On  SD Memory Card recognized  Serial disconnected  Serial normal  Door Closed  Door Open  Force Locked Door
CADENACIO  User  Manual  www.bioinsec.com 11   Force Open Door  Locked by Door Schedule  Open by Door Schedule  Lock Down (Forced lock locking device)  Lock Open (Forced open locking device)   6. Product Features   High Performance CPU  -  Capable of high speed authentication by using 32Bit 400Mhz ARM CPU    Large Built-in Memory -  It has a 128 Mbyte NAND Flash memory built into the device. -  It can additionally load a Mini SD memory. (Supports only 1GB, 2GB) SD memory is used for log and user backup.  Capable of mounting various external RF reader -  It can mount external RF readers such as MIFARE. -  It can connect RF of other companies through 1 Wiegand Input Port.   Camera Function (Option) -  Image is saved upon authentication/failure due to built-in camera. -  Capable of remote monitoring. -  When a visitor calls, you can see the face of the visitor. -  When DVR is connected via NTSC port, you can save images.  Proximity Sensor (Included in Camera Option) -  When a user approaches, the camera turns on and gives out a greeting message.
CADENACIO  User  Manual  www.bioinsec.com 12   Links with Speed Gate -  You can set the door open time in units of 1/10 second. When you set the door open time in minimum units of 0.5 seconds, it can be linked up to Speed Gate.    Built-in Key Phone Function (Option Board) -  It is capable of interphone call by linking up with a private switchboard inside a company. The door can be opened by pressing a password using a dial of the telephone while talking over the phone.   AC97 Voice Play (Wav File Play Function) -  The product supports high quality sound, and the desired sound source can be personally produced by the user, and sent to and played through the terminal.   Multi-Language Support  -  Languages such as English, Italian etc. can be set in the menu, and voice can be recorded and replaced with the desired language.   I/O Man mounted for Access Control and I/O Expansion  - Engages in encrypted data communication for high-security  -  Capable of RS485 communication for remote communication -  Supports fire alarm connection and various I/O. -  Provides 2 relay contact points as basic option.  High Reliability using Fingerprint -  It has solved security problems due to card duplication, loss, and distribution arising from Card System or Key Pad System with a fingerprint.  Various Solution -  It can be applied to various areas such as access control, time & attendance management, overtime work management, parking management, speed gate etc.  Built-in TCP/IP - TCP/IP is built into the terminal board, and multiple terminals can be managed via LAN.   Function capable of flexible implementation of Time & Attendance Management -  Functions including 4 programmable function keys and up to 9 time & attendance classification codes supports a more efficient time & attendance management. You can apply various types of functions with one terminal.  Capable of Management with Low Budget -  When ID Card is used, there is a cost for reissuing of a card when there is a new user or when a card is lost. The fingerprint recognition system can simply manage with a terminal without any additional cost.  Built-in RF Card Reader -  According to the type of reader, EM Card, Mifare(13.56MHz,  1443A)  Card,  and  Transportation  Card  can  be  used.
CADENACIO  User  Manual  www.bioinsec.com 13   Capable of Independent Use or Use in connection with a Server -  BIOINSEC’s fingerprint recognition system can be used independently or linked up with a server via TCP/IP communication. Furthermore, it can be directly connected to the independent program using SDK provided as a bundle. CADENACIO can conduct time & attendance management with its own RTC and Log management function.    Setting & Viewing of User Time Zone -  It can be controlled by groups through a combination of 32 time zones and 32 schedules, and this can be sent to the terminal.  Log Automatic Transfer -  A log is automatically sent when a terminal communicates with a server, and the sent log can be deleted from the terminal.
CADENACIO  User  Manual  www.bioinsec.com 14  7. Terminal Menu  ①  How to Use Menu  < Menu Setting Button >  4 buttons below the LCD     This is the up and down arrow keys used for moving the cursor up and down or left and right in all menus.      This switches to previous or next menu.  This cancels a task.  This completes a task and saves it.  This goes back to the previous menu.    < Keypad Setting Button >    You can select the check box ( )  upon  user  registration.  It is hereinafter referred to as “Star Button.”    When deleting the input value, it is used for the same purpose as a Back Space key. It is hereinafter referred to as “Sharp Button.”       This is used when a visitor makes a call. It is hereinafter referred to as “Call Button.”   This is pressed when going into a menu.  It is hereinafter referred to as “Menu Button.”       This is used when cancelling a task. It is hereinafter referred to as “Cancel Button.”
CADENACIO  User  Manual  www.bioinsec.com 15      This is used to complete or save a task. It is hereinafter referred to as “Enter Button.”
CADENACIO  User  Manual  www.bioinsec.com 16  ②  Entire Menu Tree The terminal is set as example menu tree when it left the factory. If user changes the value set as factory next tree menu process will be changed with your purpose.  1. User  2. Access Control 3. Network 4. Configuration 5. System                 1. User
CADENACIO  User  Manual  www.bioinsec.com 17           2. Access Control
CADENACIO  User  Manual  www.bioinsec.com 18        3. Network 4. Setup
CADENACIO  User  Manual  www.bioinsec.com 19       * If user changes the value set as factory, next tree menu process will be changed with your purpose.   2.  User Management(Registration/Edit/Delete) Menu  1. Administrator Password Registration  In order to go into the menu, administrator password must be registered. The password when the product was shipped out is “1111,” and you must change the password.  I. Button  →  Admin  password(Default  value  :  1111)  →   button II.  Setup  →   Administrator  →    Button  (Delete  Existing Password)  →  Enter  New Password  →    Button(Switchover to new line)  →  Check Password (Reenter New Password)   5. System
CADENACIO  User  Manual  www.bioinsec.com 20  III.   Button  →  Finish  : Please change the administrator password. If you wish to go into the desired menu fast, once you press the number relevant to the menu, it is immediately applied.        2. Enroll  User  ① Fingerprint  Registration  I. Button  →  Enter  Password(Default  Value  :  1111)  →   Button II. User  →   Enroll User → Enter User ID (Number)  →    Button   III.    FP  Check  (Once    is  pressed,  Repeat  Check/Uncheck)  →   Button IV. Register  FP  1  (Register  the  same  finger  twice)  →  Register  FP  2 (Register the same finger twice)   V.   Button  →  Finish  → Enter Password →   →   →   →   (Delete  Existing Password)  →  Input  New  Password  →  (Switchover  to  new  line)  → Password Check Reinput →  →  Completion
CADENACIO  User  Manual  www.bioinsec.com 21   When changing the access mode, once you press the relevant number, you can check or uncheck it.  ② Card  Registration  I.  Button  →  Enter  Password(Default  Value:1111)  →   Button II.  User →   Enroll User → Enter User ID (Number)  →    Button   III.    Card  Check  (If  you  press   Repeat  Check/Uncheck)  →   Button  →  Card gets close to number key  →  Button   IV.   Button  →  Completed   When changing the access mode, once you press the relevant number, you can check or uncheck it.    → Enter Password →   →   →   → Input User ID  (Number) →   → Check    Card →   → Approach  with  Card  Number  Key  →   →  Finish →  Enter  Password  →   →   →   → Enter  User  ID  (Number) →   → Check   FP  →   → Register  FP 1 (Register the same finger twice)  →  Register FP 2 (Register the same finger twice)  →   → Completion
CADENACIO  User  Manual  www.bioinsec.com 22  ③ Password Registration  I. Button  →  Enter  Password(Default  Value  :1111)  →   Button II.  User →   Enroll User → Enter User ID (Number)  →    Button   IV.   PIN Check (If you press    Repeat  Check/Uncheck)  →   Button  →  Enter  New Password  →  Button(Switchover  to new line)  →  Check Password (Reenter New Password) III.   Button  →  Finish  When changing the access mode, once you press the relevant number, you can check or uncheck it.  ※    Please enter the password in 4~8 digits in order to prevent its leakage.       ④ When  setting  with  Fingerprint  or  Card  When you have registered numerous fingerprints and cards and only want to authenticate one of them, check fingerprint, card or password as shown below, and then, authorize only one of them.   1.  FP 2.  CARD 3.  PIN →  Enter  Password  →   →    →   →  Input  User  ID(Number) →     →  Check    PIN →   →  Input  Password    →   (Switchover to new line)  →  Check Password (Reinput)  →    →  Finish
CADENACIO  User  Manual  www.bioinsec.com 23  What is the difference between ‘Card + Fingerprint’? When selecting ‘   Card + FP’ in access mode, both the card and the fingerprint must match in order to authorize.       3.  Edit User  In User Change, it is impossible to change the access mode. If you want to change the access mode, reregister after deleting a user.   I. Button  →  Enter  Password(Default  Value  :1111)  →   Button II.  User →    Edit User  →  Enter User ID (Number)  →    Button   V. Enter Date to Change(Impossible to change already registered access mode) →   Button   III.   Button  →  Finish  If you want to view the user list, press  (star) button in the User ID input window.  ※ If you want to quickly access the desire menu, once you press the number relevant to the menu, it is immediately applied.       → Enter Password →   →    →   →  Input  User ID (Number) →    → Input Data to Change →   →    →  Finish
CADENACIO  User  Manual  www.bioinsec.com 24  4.   Delete  User  I. Button  →  Enter  Password(Default  Value:1111)  →   Button II.  User →    Delete User  →  Enter User ID (Number)     III.   Button  →  Finish   When deleting all the users, once you press    (star) button in the User ID input window, the total number of registered users is displayed and they can be deleted together.   3. Mode  Setup  (Access  Control/Time  &  Attendance  Setup/Meals  Setup)  1. Access Control Setup (Access Control)  When using Access Control and Time & Attendance Management, please select 1. Access Control as Operation Mode.  I. Button  →  Enter  Password(Default  Value  :1111)  →    → Enter Password →   →    →   →  Input  User ID (Number) →    →  Finish
CADENACIO  User  Manual  www.bioinsec.com 25  Button II.   Access  Control  →    Operation  Mode  →   Mode  Select  →   Access Control Mode III.   Button  →  Finish     2.  Attendance Management Setup  Attendance Management can only be used when Operation Mode is ‘1. Access Control.’ (Impossible to use in ‘2. Meal Mode’) ① Key It selects a button for using attendance code.  Select time & attendance code with arrow keys or select using F1, F2, F3, and F4 as fixed keys.  1. Up/Down key : Change Time & Attendance Button (Use Over 4 Time & Attendance Code) 2. F1-F2-F3-F4    :  Fix  Time  &  Attendance  Button  (Fix  Below  4 Time & Attendance Code)   I. Button  →  Enter  Password(Default  Value  :1111)  →   →  Enter Password  →   →   →   →   →   →    →  Finish
CADENACIO  User  Manual  www.bioinsec.com 26  Button II.   Access  Control  →   Operation Mode →    Time  &  Attend  Setup →   Key → Select (   or   )  III.    Button  →  Finish   ② Item Select time & attendance code and name.   1 => F0    Access Mode(Deactivated if unnecessary) 2 => F1    Sign In (Attendance)    Capable of Auto Setup of Time 3 => F2    Sign Out (After School)    Capable of Auto Setup of Time 4 => F3    Out (Early Leave)     5 => F4    Return (Return) 6 => F5   7 => F6   8 => F7 9 => F8 1 (F0) is access mode, the default value. When access mode is unnecessary in time & attendance, please deactivate it.    <  Reporting  Time  Auto  Setup>   → Enter Password →   →   →   →   →   →   →   Yes →   →   IN →    →  Input  Time  Slot  (00:00-00:00)  →   →   → →  Enter  Password  →   →    →   →   →    → (   or   )→   →  Finish
CADENACIO  User  Manual  www.bioinsec.com 27  ※ Sign in is F1, and Sign out F2 code is fixed. After setup, sign in/sign out code is automatically changed by time slot.  (Sharp) button has the same function as Back Space (←) which deletes data.   3. Meals  Mode  When setting up meals mode, only meals function is supported. Access control and time & attendance function cannot be used.  I. Button  →  Enter  Password(Default  Value  :  1111)  →   Button II.   Access  Control  →    Operation  Mode  →   Mode  Select  →   Meal Mode   III.   Button  →  Finish  ① Meal Setup It can be set in the time slot in the order of breakfast, lunch, dinner, late-night meal, and snack. You can also set the number of menus by time slots. The terminal is not authorized outside the set time slot.  If overlapping prevention is selected, the same time slot is authorized only once.    (Sharp) Button :  (Sharp) button has the same function as Back Space (←) which deletes data            Button : Line Switchover   I. Button  →  Enter  Password(Default  Value:  1111)  →
CADENACIO  User  Manual  www.bioinsec.com 28  Button II.   Access  Control  →    Operation  Mode  →   Meals  Mode  → Breakfast/Lunch/Dinner/Late  Supper/Snack  Time  Slot  &  No.  of Menus Setup →  → Select Overlapping Prohibited (  or  )     III.   Button  →  Finish ※ It is authorized in only the set time. Time besides that is not authorized by the terminal. The number indicated on the screen is the count number authorized by the current time slot. It is not saved and automatically deleted when it is changed to the next time slot.     4. Prevention of Unnecessary Events in Attendance / Meal Counting Mode  Event prevention is a setup menu for preventing the occurrence of unnecessary log data, which can reduce the amount of data. For example, it is the log data on door open in time & attendance/ meals mode. It is unnecessary in time & attendance and meals mode.     When selecting lock event prevention, event on door open/close does not occur.    I. Button  →  Enter  Password(Default  Value  :  1111)  →   Button II.   Access  Control  →    Event  Setup  →   Mask  Event  →   Lock Event  →   Yes  III.   Button  →  Change Complete
CADENACIO  User  Manual  www.bioinsec.com 29     4. Access Door Setup  1. Use of I/O MAN  Select only when I/O MAN is used.  I. Button  →  Enter  Password(Default  Value  :1111)  →   Button II.   Access Control  →   Use I/O MAN →   Yes   III.   Button  →  Change Complete   ※  Please refer to installation manual on How to connect I/O MAN.    2. Link to Speed Gate (Change of Door Opening Time)  Set door opening time to 0.5 seconds when using the device for controlling speed gate.  The default value is set to 5 seconds.   I. Button  →  Enter  Password(Default  Value  :  1111)  →   Button →  Enter Password  →   →   →   →   →    →  Finish  → Enter Password →   →   →   →   →   →   →   →
CADENACIO  User  Manual  www.bioinsec.com 30  II.   Access Control  →   Reader →   Relay On Time → Input ‘5’   III.   Button  →  Finish  You can control the door opening time from 0.5 ~ 25.5 seconds, and the entered 5 appears as 0.5 seconds.    5. Network  1. Terminal  ID    Terminal ID is the identification number by terminal which must not be overlapped. Upon network connection, it is connected only when IP address and terminal ID matches.    I. Button  →  Enter  Password(Default  Value  :1111)  →   Button II.  Network →   Terminal ID → Input Terminal ID (1~999)   III.   Button  →  Change Complete   : Terminal ID must not be overlapped.   ※  1~999 can be used as terminal ID.    2. TCP/IP Network Connection   → Enter Password →   →   →   →  Input  Terminal  ID (1~999)  →    →  Finish →  Enter  Password  →   →    →   →   →  Input ‘5’ →  →
CADENACIO  User  Manual  www.bioinsec.com 31  ① Terminal IP Setup  I. Button  →  Enter  Password(Default  Value:1111)  →   Button II.  Network →    Network Mode  →  Input   TCP/IP   III.   Button  →  Finish IV.   Setting IP Address  →   Yes →  →    Button  →  Finish  <Normal Input Checking Procedure> I.   IP Address Setup  →   Yes →    II. 1Automatic  address  receiving  is  successful  when  address  is  like 92.168.2.XXX   III. When . . .   is  displayed,  select  ‘   IP  address  setup  →  No, Input Manually.   : When the automatically received terminal IP address is displayed as ‘0.0.0.0’, it is  a  network  environment  unable  to  automatically  receive  IP  address.  You must input manually.    →   →   →    →  Finish  → Enter Password →   →   →   →   →    →  Finish
CADENACIO  User  Manual  www.bioinsec.com 32  ② Server Setup  I. Button  →  Enter  Password(Default  Value  :1111)  →   Button II.  Network →    Network Mode  →  Select   TCP/IP   III.   Server Setup  →  Input Server Computer IP Address   IV.   Button  →  Finish   < Check Network Connection with Server Computer >   Reply OK : No problem in communiction from terminal to server computer  Time out : No communication between terminal and server computer  : If ‘Time out’ appears, there is a problem in network setting or physical connection. You must check the status of connection.   3. RS485  Network  Connection  I. Button  →  Enter  Password(Default  Value  :1111)  →   →  Enter Password  →   →    →   →  Input Server Computer IP Address →   →  Finish →  Enter  Password  →   →    →   →   →   →  Input  Server Computer IP Address →   →  Finish
CADENACIO  User  Manual  www.bioinsec.com 33  Button II.  Network →    Network Mode  →   Serial   III.   Button  →  Finish IV.  Serial Speed → Set Same as Computer Program Setup Speed →   →  Finish V.  Serial Port  →    Port 0(RS-485)  →    →  Finish     ※  For the Serial Speed, you must enter the same speed as the serial port speed of BioManager program.   ※  For how to connect to RS485, please refer to installation manual.  6. Camera  Setup  Camera is optional, and does not apply to products without camera.  1. Camera  Operation  Mode  Setup  1. Auto : Camera automatically turns on when a user approaches. It automatically turns off when there is no user.   2. On : Always on ( Used when recording with DVR or used when always monitoring )  →   →    →  Finish  →  Same as PC Program Serial Speed  →    →  Finish  → Enter Password →   →   →   →   →    →  Finish
CADENACIO  User  Manual  www.bioinsec.com 34  3. Off : Camera not used   I. Button  →  Enter  Password(Default  Value:  1111)  →   Button II.  Setup →    Camera  →   Camera Mode  →  Select    Automatic (or  On)   III.   Button  →  Finish IV.  Camera Channel  →   0 Channel →    →  Finish  ※ ‘1.Auto’ is recommended for camera operation mode.    2. Viewing  with  Camera  Check if camera is properly working from the terminal.  I. Button  →  Enter  Password(Default  Value:  1111)  →   Button II.  Setup →    Camera  →   Camera View   III.   Button  →  Finish  →  Enter  Password  →   →   →   →   → (   or   ) →   →  Finish  →   →    →  Finish
CADENACIO  User  Manual  www.bioinsec.com 35   ※  Screen is normal if it is showing the screen in the direction of 90 degrees to the right.   : If an image does not appear on the screen, the camera is not properly working. Please inquire the dealer.       7. Display  This is the LCD setup menu.    1. Lighting  Hours  Proximity sensor works in the terminal with camera option.    Default value is 10 seconds. If a person approaches the camera, it turns on in 10 seconds and automatically turns off after 10 seconds.   I. Button  →  Enter  Password(Default  Value:  1111)  →   Button II.  Setup  →    Monitor  →   BackLight Time → Input Desired Lighting Hours (0=Always On, 1~255 seconds)  III.   Button  →  Finish →  Enter Password  →   →   →   →   →    →  Finish
CADENACIO  User  Manual  www.bioinsec.com 36   LCD Always On Setup => Input ‘0’ as Lighting Hour   2.   Contrast  I. Button  →  Enter  Password(Default  Value:  1111)  →   Button II.  Setup →    Monitor  →   LCD  Contrast  →  Change  with   Button III.   Button  →  Finish   3.   Brightness  I. Button  →  Enter  Password(Default  Value:  1111)  →   Button II.  Setup →    Monitor  →   LCD Brightness  →  Change with   Button III.   Button  →  Finish  → Enter Password →   →   →   →   →   →   →  → Enter Password →   →   →   →   →  Input  Lighting Hours    (0=Always On, 1~255 seconds)  →    →  Finish
CADENACIO  User  Manual  www.bioinsec.com 37     4. Black  /  White  Mode  (Daylight  Mode)  Due to the characteristic of color LCD, it cannot be viewed well under daylight. In this case, if you select black/white mode, the main screen turns to black & white screen.   I. Button  →  Enter  Password(Default  Value:  1111)  →   Button II.  Setup →    Monitor  →    Black / White Mode  →  Select   Yes  III.   Button  →  Finish ※  While the authorization screen changes to black & white mode, the menu does not change.  5. Set  Time  This is the menu for setting the time indication format.   1. 12 hour : Displays time in AM/PM with 12 hour format. (  예  07:00PM  ) 2. 24 hour : Displays time in 24 hour format. (Ex) 19:00    )  I. Button  →  Enter  Password(Default  Value  :1111)  →    → Enter Password →   →    →   →    →   →    →  Finish  → Enter Password →   →   →   →   → Change   →    →  Finish
CADENACIO  User  Manual  www.bioinsec.com 38  Button II.  Setup →    Monitor  →    Set  Time  →  Select    12  Hours  (or   24 Hours)   III.   Button  →  Finish     6. Set  Date  This is the menu for setting the date format on the screen.     1. No : Screen is not displayed 2. MM/DD : Displays the date in the format of ‘8/13 FRI’   3. DD MON : Displays the date in the format of ’13 AUG FRI’    I. Button  →  Enter  Password(Default  Value  :1111)  →   Button II.  Setup →    Monitor  →   Set  Date  →  Select    MM/DD  (or    MM month DD date )   III.   Button  →  Finish   →  Enter  Password  →   → Select   →   →   → (   or   ) →    →  Finish
CADENACIO  User  Manual  www.bioinsec.com 39      7.   Language  For language, it only supports English and Korean. If the language changes, voice also automatically changes.  I. Button  →  Enter  Password(Default  Value:  1111)  →   Button II.  Setup →    Language  →  Select   English   III.   Button  →  Finish  ※  Only English and Korean is supported.    8. SD  Memory  Backup  &  Restore  Micro  SD Memory size supported is  only  1GB or  2GB.  (Unable to support more than 2GB) The function is supported only when the following folders are created in the SD memory card.  Please inquire the dealer for contents going into each folder.   → Enter Password →   →   →   →   →    →  Finish    → Enter Password →   → Select   →   →   → (   or   ) →    →  Finish
CADENACIO  User  Manual  www.bioinsec.com 40  Firmware   Icon   Ment   User    1. SD  Memory  Function  1. Auto log data backup function(in text format) 2. Store Camera Capture Image(Up to 10,000 images) 3. User Data Backup and Recovery 4. Terminal Setup Information Backup and Recovery 5. Firmware Update 6. Import Resource Files(Voice & Icon Files)    2. Auto  Log  Data  Backup  Function  Once you insert the SD memory into the terminal, text files are automatically created for each month, and are automatically saved without any setup process.   Log data : Save log data to SD memory  Image data : Save image data to SD memory ( Max 10K )    3. Import from SD memory  This function which allows you to save the SD memory data to terminal. The SD memory data includes a firmware, resources files(Voices, Icons), Customer value, User Files and Setup Files.     2. Resources(Voices, Icons) : Voice and Icon files 3. Customer  Value  :  T&A  Item  name,  Printer  setup  value(Meal  Model),  Mifare key value
CADENACIO  User  Manual  www.bioinsec.com 41  4. User Files : User data saved in terminal 5. Setup Files : Terminal setting value       I. Button  →  Enter  Password(Default  Value:  1111)  →   Button II.  System  →   Import from SD Memory → (  Import  Resources (Voices, Icons) /   Customer Value /    User Files /    Setup Files) III.   Button  →  Finish  Data in the terminal:  User ID, Fingerprint/Card/Password (Name and company number can be checked only in the program)  4. Export to SD Memory  This is a function which allows you to backup user data and terminal setup value saved in the terminal to SD memory.  1. User Files : User data saved in SD memory 2. Setup Files : Terminal setup value in SD memory   I. Button  →  Enter  Password(Default  Value  :1111)  →   →  Enter  Password  →   →   →   →  (  Resources  /   Customer Value /    User Files /    Setup Files )  →    →  Finish
CADENACIO  User  Manual  www.bioinsec.com 42  Button II.  System →    Export to SD Memory  →  (  User Files /    Setup Files)   III.   Button  →  Finish    5. How to Update Firmware   Firmware update is used only when there are some problems in operating the terminal or when there is an upgraded version. If the version is different, the registered data can be deleted.    I. Menu  →  Enter  Password(Default  Value:  1111)  →   Button II.  System →    Import from SD Memory  →    Firmware   III.  Button → System Reboot → Finish  When there is a different version, setup values and data may be initialized. Please inquire the dealer about which version it is.   9. Initialization   → Enter Password →   →   →   →   →   → Reboot →  → Enter Password →   →   →   → (   :  User  Files  /   : Setup Files)  →    →  Finish
CADENACIO  User  Manual  www.bioinsec.com 43  1. Init Event : Deletes only long event data 2. Init Setup : Resets only terminal setting to default values. 3. Init Factory : Deletes all the user, log, and setup values, and resets to default values.  I. Button  →  Enter  Password(Default  Value:  1111)  →   Button II.  System →    Initialize  →  Select out of (  Init Event /    Init Setup /  Init Factory)  III.   Button  →  System Reboot IV.  Button  →  Enter  Password(Default  Value  :1111)  →   Button V.  Setup →    Language  →   Korean  VI.   Button  →  Finish   10. Q&A  1. I cannot view the LCD screen from outdoors 2. Card is not authorized when using Serial PC device. 3. I want to know the Card number. 4. The fingerprint registered on the USB Fingerprint Device is not properly recognized.  → Enter Password →   →   →   → Select (  : Init Event /   Init Setup /   Init Factory)  →   → Reboot →   → Enter Password →   →   →   →   →  →  Finish
CADENACIO  User  Manual  www.bioinsec.com 44  5. The LCD screen keeps turning off and giving out a ‘beep beep’ sound.  1.  I cannot view the LCD from outdoors.  Color LCD is not very visible under daylight conditions. It is just as a cellphone screen not visible outdoors.  If you set the main screen to black & white mode, the letters and time becomes a bit clearer.  I. Button  →  Enter  Password(Default  Value:  1111)  →   Button II.  Setup →   Screen →    Black / White Mode  →   Yes III.   Button  →  Finish   2. Card  is  not  authorized  when  using  Serial  PC  Device.  When using a Serial PC device, because the card data value and the terminal default value is different, you have to set options.  I. Button  →  Enter  Password(Default  Value  :1111)  →   Button II.   Access  Control  →    Readers  Setup→    Mifare  Card  Reader  →   Serial Number  →    Reverse order   III.   Button  →  Finish  → Enter Password →   →   →   →   →   →    →  Finish
CADENACIO  User  Manual  www.bioinsec.com 45    3. I want to know the Card Number.  When you want to check the card number registered in the terminal, you can easily view it if you use View Card Number in the menu.    I. Button  →  Enter  Password(Default  Value:  1111)  →   Button II.   Access  Control  →    Readers  Setup  →    Mifare  Card  Reader  →   Reading Card → Hold card close to keypad (or fingerprint sensor) (Wiegand  리더기일  경우, Wiegand  리더기  안에  카드보기  메뉴가  있음) III.   Button  →  Finish   4. The  fingerprint  registered  on  the  USB  Fingerprint  Device   is not properly recognized.  When registering a fingerprint, the fingerprint core must be in the taken image. Please re-register. In addition, if there is difference in the level of exposure between the USB fingerprint device and the  → Enter Password →   →   →   →   →   →Touch Card →   →  Finish  → Enter Password →   →   →   →   →   →   →   → Finish
CADENACIO  User  Manual  www.bioinsec.com 46  terminal, this may occur.   Please change the fingerprint sensor exposure value in the menu to ‘5.’    I. Button  →  Enter  Password(Default  Value:  1111)  →   Button II.   Access  Control  →    Readers  Setup  →   FP Reader →    Exposure →  Set to ‘5’     III.   Button  →  Finish   5. The  LCD  screen  keeps  turning  off  and  giving  out  a  ‘beep beep’  sound.  This may happen if the proximity sensor is activated or if the terminal without a built-in proximity sensor is set to use proximity sensor. Enter lighting hours to ‘0.’    I. Button  →  Enter  Password(Default  Value  :1111)  →   Button II.  Setup →    Monitor  →    BackLight Time  →  Enter ‘0’    III.   Button  →  Finish  → Enter Password →   →   →   →   →   fingerprint exposure level  →  Set to ‘5’  →    →  Finish
CADENACIO  User  Manual  www.bioinsec.com 47     → Enter Password →   →   →   →   → Enter  ‘0’    →   →  Finish
CADENACIO  User  Manual  www.bioinsec.com 48  GLOSSARY  □ Administrator -  The administrator has the authority to modify or set all setup values of the terminal, and register or delete new users. - The first ID of the administrator is the number ‘0,’ and the first password of the terminal is ‘1111.’   A NEW ADMINISTRATOR MUST CHANGE THIS VALUE.    □ 1 to 1 Verification   -  This is a way to compare fingerprints among fingerprint recognition methods. It pre-selects a user’s fingerprint with an ID or card and compares the fingerprints.     □ 1 to N Identification   -  This is a method in which all the fingerprints registered in the terminal searches for the user by comparing all fingerprints with fingerprints of an individual.   □ Authentication Grade - This is a standard grade for determining the authentication according to the similarity of fingerprints when comparing fingerprints. Generally, it is suitable to set it to ‘normal.’ □ Authentication Method -  This is a method of identifying a user using a fingerprint, password, and RF card. There are various combinations from authenticating with each respective method to a method of final authentication only when all the fingerprint, password, and RF card are authenticated.    □ Function Key - This refers to a key setting the current mode such as sign in, sign out, outing, and returning to office upon user authentication in time & attendance mode.   Each function key is set from the menu. Furthermore, you can have this setting displayed on the basic screen in the format of ‘F1' and ‘F2,’ or ‘sign in,’ and ‘sign out.’  □ IOMAN (optional)
CADENACIO  User  Manual  www.bioinsec.com 49  - When connecting additional I/O to Cadenacio, I/O MAN is connected. It is safe due to encrypted communication with the terminal, and it can be interlinked with additional I/O such as locks and fire sensors.   □   Link up with Key Phone (optional)  -  This is a module installed inside the terminal. Once you install this board and connect to the in-company key phone, you can connect to a phone by pressing the extension number and have a phone conversation. It also has a function allowing the user to open the door during a phone conversation using a dial button on the phone.         □   Camera (optional)  - This is a camera module built into Cadenacio. It takes photos when somebody attempts to authenticate with a fingerprint, card, or password, and sends it to a server. When a visitor rings the bell, you can check the person’s face with the program. Because there is a NTSC camera port, it can be linked up to a DVR. □ Proximity Sensor (included in camera option)   -  It is a sensor built into the front side of the terminal. If a person approaches from a distance of more than 1m, it sends up a signal to light up the LCD screen and automatically activate the camera.
CADENACIO  User  Manual  www.bioinsec.com 50  PRODUCT SPECIFICATION CPU    32bit Micro processor,    400MHz   Memory    NAND Flash 128Mbyte, 64Mbyte RAM   Backup Memory(optional)  Mini SD Memory 1Gbyte   LCD    2.8” color LCD   Sensor    Optic, 500 DPI   NTSC Camera(optional)    Built-in Focal length : 3.7mm   Iris : fixed   Angle Of view : 92˚(D)   Proximity Sensor(optional)  Camera automatically turns on in proximity Size    (W)149mm X (L)132mm X (D)52mm   Fingerprint data size    512 byte   Registered Personnel    1:N user: 3,000 persons   RF card : 10,000 persons   Log data : 100,000 data   IN/OUT port    Input : Door sensor, Lock sensor   Output : Lock relay, Exit button   *When linked up to I/O MAN Lock 2 port , Exit button, Fire alarm, Door sensor,   Lock sensor, Output 2 port, Spare I/O 5 port   Communication  TCP/IP     Language/Voice    Korea/ English (Support multi languages)   User can change voice file (Wave File only)   Key phone(option)    Capable  of  extension  call  linked  up  with  internal switchboard(Key phone) Power consumption    400mA   Built-in RF  Mifare(13.56MHz, ISO14443A) Built-in option    Camera, Keyphone Call Other option    I/O MAN