  8F., No.192, Sec. 2, Zhongxing Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.). TEL: + 886-2-2914-5665            FAX: + 886-2-2918-6731, +886-2-2918-2895 www.billion.com  - 2 -  Revision History Document   Release Date  Modification  Initials  Approved Version 0.1  2014/03/28  1.  First release  Shengyen. Fan  Ivan. Chen Version 0.2  2014/09/18  1.  Recommended design PCIE LTE connect maximum power Vic. Lee  Ivan. Chen Version 0.3  2014/12/01  1.  Band 41 only  Vic. Lee  Ivan. Chen
  8F., No.192, Sec. 2, Zhongxing Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.). TEL: + 886-2-2914-5665            FAX: + 886-2-2918-6731, +886-2-2918-2895 www.billion.com  - 3 -  1.  General Description 1-1. Product Overview and Functional Description Billion Electric Co., Ltd. WW-ML067 is a (4G) LTE mini-PCIE module. It implements 3GPP release 9 modem on a mini-PCI Express card. It supports next-generation LTE standards with Category 4 150Mbps for DL and 50 Mbps for UL (megabits-per-second) throughput. User can surf internet by WW-ML067 in anywhere  and  anytime  where  4G  TD-LTE  (Band  41)  networks  covered.  WW-ML067  is  designed  to provide fast, reliable and easy user experience.      WW-ML067 uses Marvell PXA1802 communications processor. The PXA1802 is an advanced, highly integrated  Long-Term  Evolution  (LTE)  modem  for  multimedia-centric  handsets.  The  PXA1802  solution incorporates mature and proves LTE technology to provide Mobile handset platform.  <FCC Part 15.21 statement>   ‧Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.   ‧This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter.   <FCC Part 15.105 statement> Note: This equipment has been tested  and found to comply with the limits for  a class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference  in  a  residential installation. This equipment  generates  uses  and can radiate  radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this  equipments does cause harmful interference or television reception, which can  be  determined  by  turning  the  equipment  off  and  on,  the  user  is  encouraged  to  try  to  correct  the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. A simplified block diagram of the WW-ML067 module is depicted in the figure below.
  8F., No.192, Sec. 2, Zhongxing Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.). TEL: + 886-2-2914-5665            FAX: + 886-2-2918-6731, +886-2-2918-2895 www.billion.com  - 4 -  RF exposure statements: Information to OEM integrator The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module in the user manual of the end product. The user manual which is provided by OEM integrators for end users must include the following information in a prominent location. 1. To comply with FCC RF exposure compliance requirements, the antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. 2. Only those antennas with same type and lesser gain filed under this FCC ID number can be used with this device. 3. The regulatory label on the final system must include the statement: “Contains FCC ID: xxxx or using electronic labeling method as documented in KDB 784748. 4. The final system integrator must ensure there is no instruction provided in the user manual or customer documentation indicating how to install or remove the transmitter module except such device has implemented two ways authentication between module and the host system. This module can't be used on radio system and operation individually. Using others antenna must be re-testing and certification.
  8F., No.192, Sec. 2, Zhongxing Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.). TEL: + 886-2-2914-5665            FAX: + 886-2-2918-6731, +886-2-2918-2895 www.billion.com  - 5 -  1-2. Antenna Description 1.) Type #1 Dipole:   2.) Type #2 Dipole:
  8F., No.192, Sec. 2, Zhongxing Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.). TEL: + 886-2-2914-5665            FAX: + 886-2-2918-6731, +886-2-2918-2895 www.billion.com  - 6 -  3.) Type #3 Patch antenna:  RF Specification Frequency range  2500-2700 MHz Polarization  Linear, Vertical / Horizontal HPBW/Horizontal  Port 1:22∘∘∘∘/ Port 2:21∘∘∘∘ HPBW/Vertical  Port 1:23∘∘∘∘/ Port 2:22∘∘∘∘ Peak Gain  11.5 dBi (Cable Loss Included) VSWR  2.0 max:1 Isolation  20 dB typ. Power handing  2W (cw) Impedance  50 Ohms Cable  Ф1.37, 250mm (Port1: Gray; Port2: White) Connector  U.FL x2  4.) Type #4   Dipole (全頻全頻全頻全頻)
  8F., No.192, Sec. 2, Zhongxing Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.). TEL: + 886-2-2914-5665            FAX: + 886-2-2918-6731, +886-2-2918-2895 www.billion.com  - 7 -    Figure 1. WW-ML067 Mini-PCIE Module Block Diagram  1-2. Key Features   Supported Frequency Bands TDD-LTE Band 41  Supported Network Modes Time Division Long Term Evolution (TDD-LTE)  Provided Services High-speed LTE packet data service of up to 150 Mbit/s  *Maximum data rate is subject to 4G services provided by network operators  1-3. Main Features  Supported Features Downlink LTE packet data service of up to 150 Mbit/s   Uplink LTE packet data service of up to 50 Mbit/s   Packet switched (PS) domain data service based on LTE   Linux 2.6.29 and later
  8F., No.192, Sec. 2, Zhongxing Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.). TEL: + 886-2-2914-5665            FAX: + 886-2-2918-6731, +886-2-2918-2895 www.billion.com  - 8 -  2.  Technical Specifications Table  2-1Hardware Model Name  WW-ML067 Product Description  Specifications Major Chipset Marvell PXA1802 Standards Compliance LTE 3GPP Release 9 compliant WAN: LTE Band 41  External Interfaces Supporting USB 2.0 high speed Standard 6-pin SIM card interface  Operating Conditions Voltage  3.3 V Current(peak)  1.6±±±±0.2 A Ambient Temperature Operating: Operating::::-10  to +55℃℃℃℃ ℃℃℃℃ Storage: -20℃℃℃℃  to +70℃℃℃℃ Dimension  Dimensions (L × W × H)::::50.95mm x 30mm x 4.82mm Weight  About 12g Electrical Specifications Operating Frequency TDD-LTE::::  Band 41 (2496 MHz ~ 2690 MHz) Maximum transmit power  TDD-LTE: 23  ±±±±2 dBm (Power Class 3) Antenna Embedded  TDD -LTE: Main antenna connector.  TDD -LTE: Receive diversity antenna connector. Receiver Sensitivity  TDD-LTE: compliant with Category 4
  8F., No.192, Sec. 2, Zhongxing Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.). TEL: + 886-2-2914-5665            FAX: + 886-2-2918-6731, +886-2-2918-2895 www.billion.com  - 9 -  2-2 Software  Others   Network connection:    Automatic network selection and registration    Manual network selection and registration    Optional network connection types, for example:    4G only  PIN management:  Edit    Enable/Disable    Verify
  8F., No.192, Sec. 2, Zhongxing Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.). TEL: + 886-2-2914-5665            FAX: + 886-2-2918-6731, +886-2-2918-2895 www.billion.com  - 10 -  3.  Electrical Characteristics  3-1. Recommended DC power supply for Micro USB   Power  Tolerance  Units 3.3V ±5%  V  3-2. Recommended design PCIE LTE connect peak current Band  Current  Units LTE 1.6±0.2  A
  8F., No.192, Sec. 2, Zhongxing Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.). TEL: + 886-2-2914-5665            FAX: + 886-2-2918-6731, +886-2-2918-2895 www.billion.com  - 11 -  4.  Mechanical drawing
  8F., No.192, Sec. 2, Zhongxing Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.). TEL: + 886-2-2914-5665            FAX: + 886-2-2918-6731, +886-2-2918-2895 www.billion.com  - 12 -  5.  Pin Definition Pin Assignment   Pin No Definition  Basic Description  Type   1  NC  NC    2  VCC3P3  +3.3V power supply  I  Power 3  JTAG TRST_N  JTAG TRST_N    4  GND-4  GND    5  JTAG TDI  JTAG TDI    6  JTAG TDO  JTAG TDO    7  NC NC    8  USIM_PWR VCC USIM    9  GND-9  GND    10  USIM_DATA USIM DATA    11  JTAG TMS  JTAG TMS    12  USIM_CLK USIM CLK    13  JTAG_TCK JTAG TCK    14  USIM_RESET USIM_ RESET    15  GND-15  GND    16  NC NC    17  UART_RXD UART_RXD    18  GND-18  GND    19  UART_TXD UART_TXD    20  W_Disable WWAN DISABLE    21  GND-21  GND    22  PERSTn  WWAN RESET    23  NC NC    24  VCC3P3  +3.3V power supply    25  NC NC    26  GND-26  GND    27  GND-27  GND    28  NC NC    29  GND-29  GND    30  I2C_SCL I2C_SCL    31  NC NC   *
  8F., No.192, Sec. 2, Zhongxing Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.). TEL: + 886-2-2914-5665            FAX: + 886-2-2918-6731, +886-2-2918-2895 www.billion.com  - 13 -  Pin No Definition  Basic Description  Type   32  I2C_SDA I2C_SDA    33  Module Enable Module Enable  I   34  GND-34  GND    35  GND-35  GND    36  USB_D-  USB_DMNS  I/O  37  GND-37 GND    38  USB_D+  USB_DPLS  I/O  39  VCC3P3  +3.3V power supply  I  Power 40  GND-40  GND    41  VCC3P3  +3.3V power supply  I  Power 42  WWAN_LED WWAN_LED    43  GND-43  GND    44  NC NC    45  NC  NC    46  NC NC    47  NC  NC    48  NC NC    49  NC NC    50  GND-50  GND    51  NC NC    52  VCC3P3  +3.3V power supply  I  Power
  8F., No.192, Sec. 2, Zhongxing Rd., Xindian Dist., New Taipei City 231, Taiwan (R.O.C.). TEL: + 886-2-2914-5665            FAX: + 886-2-2918-6731, +886-2-2918-2895 www.billion.com  - 14 -  6.  Power Delivery Requirements Requirement  Description Supply Voltage  3.3V within 5% tolerance on the motherboard. Peak Current The host board shall provide 2.5 A peak current. Max in-rush Current The Module boots maximum in-rush current of 6 A will be supported. Power Stability  Use tantalum value more than 1000uF for power input (3.3V).  7.  Minimum Rx Sensitivity – LTE LTE Band  Duplex    Modulation  Bandwidth(MHz)  Rx Sensitivity(dBm) 41  TDD  QPSK  20 -95±±±±1

Navigation menu