Barco N V ST150B01 Panel PC User Manual

Barco N.V. Panel PC

User manual

ST-150BUser guideK5903075/01AD16/01/2014
Barco nvPresident Kennedypark 35, 8500 Kortrijk, BelgiumPhone: +32 56.23.32.11Fax: +32 56.26.22.62Support: www.barco.com/esupportVisit us at the web: www.barco.comPrintedinBelgium
Table of contentsTABLE OF CONTENTS1. Welcome! .......................................................................................... 31.1 About the product ............................................................................................. 31.2 What’s in the box.............................................................................................. 32. Parts, controls and connectors ............................................................... 52.1 System setup.................................................................................................. 53. System installation .............................................................................. 113.1 Mounting .......................................................................................................113.2 Installation .....................................................................................................113.3 Installation of HDD, SSD (optional) .........................................................................123.4 Running the BIOS setup program...........................................................................123.5 Installing system software....................................................................................123.6 Installing the drivers ..........................................................................................134. System operation ................................................................................ 154.1 Frequently used functions....................................................................................155. Maintenance ....................................................................................... 175.1 Cleaning instructions .........................................................................................176. Important information ........................................................................... 196.1 Safety information.............................................................................................196.2 Environmental information ...................................................................................216.3 Regulatory compliance information .........................................................................236.4 EMC notice ....................................................................................................236.5 Explanation of symbols.......................................................................................276.6 Legal disclaimer...............................................................................................296.7 Technical specifications ......................................................................................29K5903075 ST-150B 16/01/2014 1
Table of contents2K5903075 ST-150B 16/01/2014
1. Welcome!1. WELCOME!1.1 About the productSmart TerminalThe ST-150B is a multimedia Intel® Atom processor-based computer that is designed to serve as a Pointof Care (POC) and Point of Information terminal (POI) within healthcare applications. It is a PC basedsystem with 15" color TFT LCD display, Gigabit Ethernet, multi-COM port and USB 2.0 interfaces andHigh Definition Audio codec.The ST-150B Smart Terminal™ is as compact and user-friendly as a notebook computer. This simple,complete and highly integrated multimedia system lets system integrators easily build the ST-150B SmartTerminal™ into their applications.The device is not intended to be used in patient monitoring, diagnosis,treatment,alle-viation or prevention of diseases, injuries and handicaps.CAUTION:Read all the important safety information before installing and operating yourST-150B. Please refer to the dedicated chapter in this user guide.1.2 What’s in the boxOverviewYour ST-150B comes with:• PSU & Power cord — USA, European, UK types (where applicable)• Handset & Coiled Cable (where applicable)• Accessories for the ST-150B (where applicable)Keep your original packaging. It is designed for this terminal and is the ideal protection during transportand storage.WARNING:To prevent electric shock, DO NOT remove covers. No user serviceableparts inside, refer servicing to qualified personnel.K5903075 ST-150B 16/01/2014 3
1. Welcome!4K5903075 ST-150B 16/01/2014
2. Parts, controls and connectors2. PARTS, CONTROLS ANDCONNECTORS2.1 System setupBecome familiarBefore you set up the ST-150B, take a moment to become familiar with the locations and purposes of thecontrols, drives, connections and ports, which are illustrated in the figures below.FrontWhen you place the ST-150B upright on the desktop, its front panel appears as shown in the figure below.12Image 2-1Front view of the ST-150B1Membrane which contains functions: Power, Volume Up/Down, Backward/Forward, Stop,Play/Pause and Channel Up/Down2WebcamK5903075 ST-150B 16/01/2014 5
2. Parts, controls and connectorsLeft, RightWhen you look at the left side of the ST-150B, you will see a handset, fitted to the left docking port. At theright side of the terminal, you will see an MSR reader, fitted to the right docking port.1 2Image 2-2Side views of the ST-150B1Handset (optional)2MSR Reader (Mag Stripe Reader) (optional)BottomOn the bottom side of the ST-150B you will findaSmartCardReaderandanI/Oarea,asshowninthefigure below.1 2Image 2-3Bottom view of the ST-150B1SCR (Smart Card Reader)2I/O area bottom6K5903075 ST-150B 16/01/2014
2. Parts, controls and connectorsRearOn the rear of the ST-150B you will find the two removable access doors located left and right of theterminal. The right-hand cover provides access to the system DDR memory and a mini PCIe slot, and theleft-hand cover provides access to the HDD, as shown in the figure below.123Image 2-4Rear view of the ST-150B1Access door to HDD*2I/O area rear3Access door to System DDR memory and mini PCIe slot*CAUTION:* The access doors may only be opened by qualified service personal, nouser serviceable parts inside.K5903075 ST-150B 16/01/2014 7
2. Parts, controls and connectorsIO areasThere are two I/O areas in the ST-150B; one is at the back and the other one is at the bottom. The figuresbelow indicate the various ports of these two areas.1 2 3 4 5Image 2-5I/O ports at the back of the ST-150B18P8C handset connector +Fin Service Call Connector2RJ 45 Shielded Gigabit Ethernet Connector3USB Connector4USB Connector5Power Connector1 2 3 4 5Image 2-6I/O ports at the bottom of the ST-150B1USB Connector (2x)2Microphone Jack3Headset Jack (2x)4DVI-I Connector526-Way MDR Connector (for optional remote control or a Service Call device)The RJ9 socket is for handset connection only.8K5903075 ST-150B 16/01/2014
2. Parts, controls and connectorsLabel location2134Image 2-7Label location1Intel® label2FCC label WiFi module3FCC label Bluetooth4Rating labelK5903075 ST-150B 16/01/2014 9
2. Parts, controls and connectors10 K5903075 ST-150B 16/01/2014
3. System installation3. SYSTEM INSTALLATION3.1 MountingFixing the terminal to a mounting solutionThe terminal is foreseen from a mounting anchor that can be used for different mounting solutions (arms,desk stands, ...).To install the terminal, please follow the detailed mounting instructions in the user guide, which is deliveredwith the mounting solution you have chosen for your terminal.3.2 InstallationConnecting the power cableAlways handle the power cable by holding the plug end only. Follow these steps:1. Connect the male end of the power supply DIN cable to the DC inlet of the ST-150B, see figure below.2. Connect the male plug of the power supply to an electrical outlet.Image 3-1Connecting the power cableConnecting USB keyboard and mouse1. Connect the keyboard and mouse to the USB ports located on the bottom cover of the ST-150B, seefigure below.Image 3-2Connecting the keyboard and mouseSwitching on the power1. Switch on the ST-150B via the power switch on the front cover, see figure below.K5903075 ST-150B 16/01/2014 11
3. System installationImage 3-3Switching on the power3.3 Installation of HDD, SSD (optional)CAUTION:The installation of the optional HDD and/or SSD drive should be carried outby a professional technician. Only UL-certified hard disks may be installed!Please contact a service technician or your reseller if you need this service.3.4 Running the BIOS setup programBIOS setupYour ST-150B is likely to have been properly set up and configured by your dealer prior to delivery. Ifyou still find it necessary to use the BIOS (Basic Input-Output System) setup program to change systemconfiguration information please contact Barco for support.The settings you specify with the setup program are recorded in a special area of memory called CMOSRAM. This memory is backed up by a battery so that it will not be erased when you turn off or resetthe system. Whenever you turn on the power, the system reads the settings stored in CMOS RAM andcompares them to the equipment check conducted during the power on self-test (POST). If an error occurs,an error message will be displayed on screen, and you will be prompted to run the setup program.3.5 Installing system softwareSetup and installation instructionsRecent releases of operating systems from major vendors include setup programs which load automati-cally and guide you through hard disk preparation and operating system installation. The guidelines belowwill help you determine the steps necessary to install your operating system on the ST-150B. If required,insert your operating system’s installation or setup disc into a portable optical drive and plug into one ofthe ST-150B USB ports.Some distributors and system integrators may have already pre-installed system soft-ware prior to shipment of your ST-150B.If you are presented with a setup/installation screen then carefully follow the instructions. The setup pro-gram will guide you through preparation of your hard drive, and installation of the operating system.12 K5903075 ST-150B 16/01/2014
3. System installation3.6 Installing the driversDriversAfter installing the system software, you will be able to install the necessary drivers. All the ST-150Bdrivers and updates can be obtained from Barco.The drivers and utilities used for the ST-150B are subject to change without notice. Ifin doubt, check with your local Barco office or contact our application engineers for thelatest information regarding drivers and utilities.K5903075 ST-150B 16/01/2014 13
3. System installation14 K5903075 ST-150B 16/01/2014
4. System operation4. SYSTEM OPERATION4.1 Frequently used functionsUsing the Smart Card Reader (SCR)1. Insert the card firmly into the allocated slot with the chip facing towards the front of the terminal. (Seefigure below). The Smart Card will be recognized by the terminal.Image 4-1Using the Smart Card Reader (SCR)Using the RFID Reader1. Present the card to the reader by tapping and holding it brieflyonto the clearly reader-marked area untilthe card is read.Image 4-2Using the RFID readerUsing the MagStripe Reader (MSR)1. Insert the card firmly into the allocated slot with the chip facing towards the side of the terminal. (Seefigure below). The Magnetic Stripe Card will be recognized by the terminal.K5903075 ST-150B 16/01/2014 15
4. System operationImage 4-3Using the Magnetic Stripe Reader (MSR)16 K5903075 ST-150B 16/01/2014
5. Maintenance5. MAINTENANCEThis device does not require any scheduled maintenance activities. In case of a defect,return the device to a Barco approved maintenance organization. In any case of doubts,contact the Barco Healthcare Division5.1 Cleaning instructionsCleaning is no mandatory maintenance activity for the ST-150B.During normal use, the ST-150B surfaces may become soiled. If you should like to cleanthem, follow the detailed cleaning instructions in the below paragraph.To clean the terminalExamples of approved cleaning agents:• Green tinctured soap and Enzymatic detergents• Mediwipes• Vernacare wipes1. Prepare agent per manufacturer’s instructions or hospital protocol.2. Wipe the ST-150B with a clean cloth that has been moistened in the cleaning solution.3. Wipe thoroughly with a clean cloth.The ST-150B’s surfaces are resistant to the following cleaning materials:• Isopropyl alcohol• Ammonia-based glass cleaners• Turpentine• Mineral spiritsCAUTION:Do not immerse or rinse the ST-150B and its peripherals. If you acciden-tally spill liquid on the device, disconnect the unit from the power source. Contact yourBiomed regarding the continued safety of the unit before placing it back in operation.Do not spray cleaning agent on the chassis.Do not use disinfectants that contain phenol. Do not autoclave or clean the ST-150B orits peripherals with strong aromatic, chlorinated, ketone, ether, or ester solvents, sharptools or abrasives. Never immerse electrical connectors in water or other liquids.In environments where specific chemicals or cleaning agents are required to be used,please contact Barco.K5903075 ST-150B 16/01/2014 17
5. Maintenance18 K5903075 ST-150B 16/01/2014
6. Important information6. IMPORTANT INFORMATION6.1 Safety informationGeneral recommendationsRead the safety and operating instructions before operating the device.Retain safety and operating instructions for future reference.Adhere to all warnings on the device and in the operating instructions manual.Follow all instructions for operation and use.Electrical Shock or Fire HazardTo prevent electric shock or fire hazard, do not remove cover.No serviceable parts inside. Refer servicing to qualified personnel.Do not expose this apparatus to rain or moisture.Safety instructions• Do not modify this equipment without authorization of the manufacturer.• The equipment must be powered using the delivered medical approved DC power supply only.• The medical approved DC power supply must be powered by the AC mains voltage (protective earthterminal).To avoid the risk of electric shock, this equipment must only be connected to a supplymains with protective earth.• Make sure the voltage of the power source is correct before connecting the equipment to the poweroutlet.• Position the power cord so that it is not a hazard. Do not place anything over the power cord.• If the equipment is out of use for an extended period, make sure to disconnect it from the power sourceto avoid damage in the event of a power surge.• Earth the ST-150B by connecting the protective earth pin to a grounded outlet by means of the suppliedwire.• If one of the following situations arises, ensure you get the equipment checked by service personnel:a) The power cord or plug is damaged.b) The equipment has been exposed to moisture.c) The equipment is not functioning properly, or you cannot get it to work according to the user manual.d) The equipment has been dropped and damaged.e) The equipment has obvious signs of breakage.• To disconnect the device: Remove the rear power supply power connection.• If your computer is losing time or the BIOS configuration resets to default settings, the battery mostlikely has no power.• Do not replace the battery yourself. Please contact a qualified technician or your supplier of theST-150B. The ST-150B is provided with a battery-powered real-time clock circuit. There is a dangerof leakage or explosion if the battery is incorrectly replaced. Replace only with same or equivalenttype recommended by the manufacturer. Discard used batteries according to the manufacturer’s in-structions.K5903075 ST-150B 16/01/2014 19
6. Important information•Warning: if the equipment is not used for a long time, please make sure that the battery is removedfrom the equipment.• Place the terminal on a stable surface that can support the weight of at least 4 terminals or hang froma reliable structure during installation. Dropping the equipment is likely to cause serious injury to achild or adult, and serious damage to the equipment.• Improper installation of VESA mounting can result in serious personal injury! Use a VESA mountingsolution that can support a weight of at least 10kg. VESA mount installation should be carried out by aprofessional technician. Please contact the service technician or your reseller if you need this service.• Keep this equipment away from excessive humidity.• Do not pour any liquid into the vents on the terminal. This may cause fire or electrical shock.• The vents on the enclosure are for air convection and protect the equipment from overheating. Do notcover the vents.When installing the terminal in a cupboard or another closed location, heed the necessary space be-tween the set and the sides of the cupboard.• Do not leave this equipment in an uncontrolled environment where the storage temperature is below-20 °C or above 60°C. This may damage the equipment.• Equipment not suitable for use in the presence of a flammable anesthetic mixture with air or withoxygen or nitrous oxide.• For more information about recycling of this product, please contact your local city office, your munic-ipal waste disposal service or the shop where you purchased the product.• This equipment is not intended to be used in life support systems, operating rooms or for diagnosticpurposes.• External connections to model ST-150B (I/O, LAN, etc) shall be in compliance with the requirementsfor medical electrical systems as stated in chapter 16 of the standard for medical electrical equipmentIEC 60601-1: 2005.• Accessory equipment connected to the analog and digital interfaces must be in compliance with therespective nationally harmonized IEC standards (i.e. IEC 60601 for data processing equipment). If indoubt, consult the technical services department or your local representative.Type of protection (electrical):Display with external power supply: Class I equipment.Degree of safety (flammable anesthetic mixture):Equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygenor nitrous oxide.Non-patient care equipment• Equipment primarily for use in a health care facility that is intended for use where contact with a patientis unlikely (no applied part).• The equipment may not be used with life support equipment.• The user is not supposed to touch SIP/SOPs and the patient at the same time.Power connection – Equipment with external 19 VDC power supply• Power requirements: The equipment must be powered using the delivered medical approved 19 VDC() power supply.• The medical approved DC ( ) power supply must be powered by the AC mains voltage.• The power supply is specified as a part of the ME equipment or combination is specified as a MEsystem.• To avoid the risk of electric shock, this equipment must only be connected to a supply mains withprotective earth.• The equipment should be installed near an easily accessible outlet.• The equipment is intended for continuous operation.20 K5903075 ST-150B 16/01/2014
6. Important informationTransient over-voltageIf the device is not used for a long time, disconnect it from the AC inlet to avoid damage by transientover-voltage.To fully disengage the power to the device, please disconnect the power cord from the AC inlet.Power cords:• Utilize a UL-listed detachable power cord, 3-wire, type SJ or equivalent, 18 AWG min., rated 250 Vmin., provided with a hospital-grade type plug 5-15P configuration for 120V application, or 6-15P for240V application.• Do not overload wall outlets and extension cords as this may result in fire or electric shock.• Mains lead protection (U.S.: Power cord): Power cords should be routed so that they are not likely tobe walked upon or pinched by items placed upon or against them, paying particular attention to cordsat plugs and receptacles.• The power supply cord should be replaced by the designated operator only at all time.• Use a power cord that matches the voltage of the power outlet, which has been approved and complieswith the safety standard of your particular country.VentilationDo not cover or block any ventilation openings in the cover of the set. When installing the device in acupboard or another closed location, heed the necessary space between the set and the sides of thecupboard.This apparatus conforms to:ANSI/AAMI ES 60601-1:2005; CAN/CSA-C22.2 No.60601-1:08; FCC-Class A; CE6.2 Environmental informationDisposal InformationWaste Electrical and Electronic EquipmentThis symbol on the product indicates that, under the European Directive 2012/19/EU governingwaste from electrical and electronic equipment, this product must not be disposed of with other municipalwaste. Please dispose of your waste equipment by handing it over to a designated collection point for therecycling of waste electrical and electronic equipment. To prevent possible harm to the environment orhuman health from uncontrolled waste disposal, please separate these items from other types of wasteand recycle them responsibly to promote the sustainable reuse of material resources.For more information about recycling of this product, please contact your local city office or your municipalwaste disposal service.For details, please visit the Barco website at: http://www.barco.com/en/AboutBarco/weeeDisposal of batteries in the productThis product contains batteries covered by the Directive 2006/66/EC which must be collected anddisposed of separately from municipal waste.If the battery contains more than the specified values of lead (Pb), mercury (Hg) or cadmium (Cd), thesechemical symbols will appear below the crossed-out wheeled bin symbol.K5903075 ST-150B 16/01/2014 21
6. Important informationBy participating in separate collection of batteries, you will help to ensure proper disposal and to preventpotential negative effects on the environment and human health.Turkey RoHS complianceTürkiye Cumhuriyeti: AEEE Yönetmeliğine Uygundur.[Republic of Turkey: In conformity with the WEEE Regulation]中国大陆RoHSChinese Mainland RoHS根据中国大陆《电子信息产品污染控制管理办法》(也称为中国大陆RoHS), 以下部分列出了Barco产品中可能包含的有毒和/或有害物质的名称和含量。中国大陆RoHS指令包含在中国信息产业部MCV标准:“电子信息产品中有毒物质的限量要求”中。According to the “China Administration on Control of Pollution Caused by Electronic Information Products”(Also called RoHS of Chinese Mainland), the table below lists the names and contents of toxic and/orhazardous substances that Barco’s product may contain. The RoHS of Chinese Mainland is included inthe MCV standard of the Ministry of Information Industry of China, in the section “Limit Requirements oftoxic substances in Electronic Information Products”.零件项目(名称)Component name有毒有害物质或元素Hazardous substances and elements铅Pb汞Hg镉Cd六价铬Cr6+多溴联苯PBB多溴二苯醚PBDE印制电路配件Printed Circuit Assembliesxooo oo外接电(线)缆External Cablesxooo oo內部线路Internal wiringoo oo oo塑胶外壳Plastic enclosureoo oo oo电源供应器Power Supply Unitxooo oo风扇Fanoo oo oo文件说明书Paper Manualsoo oo oo光盘说明书CD manualoo oo ooO: 表示该有毒有害物质在该部件所有均质材料中的含量均在 SJ/T 11363-2006 标准规定的限量要求以下.O: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials forthis part is below the limit requirement in SJ/T11363-2006.X: 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 SJ/T 11363-2006 标准规定的限量要求.X: Indicates that this toxic or hazardous substance contained in at least one of the homogeneousmaterials used for this part is above the limit requirement in SJ/T11363-200622 K5903075 ST-150B 16/01/2014
6. Important information在中国大陆销售的相应电子信息产品(EIP)都必须遵照中国大陆《电子信息产品污染控制标识要求》标准贴上环保使用期限(EFUP)标签。Barco产品所采用的EFUP标签(请参阅实例,徽标内部的编号使用于制定产品)基于中国大陆的《电子信息产品环保使用期限通则》标准。All Electronic Information Products (EIP) that are sold within Chinese Mainland must comply with the“Electronic Information Products Pollution Control Labeling Standard” of Chinese Mainland, marked withthe Environmental Friendly Use Period (EFUP) logo. The number inside the EFUP logo that Barco uses(please refer to the photo) is based on the “Standard of Electronic Information Products EnvironmentalFriendly Use Period” of Chinese Mainland.106.3 Regulatory compliance informationIndications for useThe ST-150B is not intended to be used in patient monitoring, diagnosis, treatment, alleviation or preven-tion of diseases, injuries and handicaps.RF exposure warningThis equipment must be installed and operated in accordance with provided instructions and the an-tenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cmfrom all persons and must not be co-located or operating in conjunction with any other antenna or trans-mitter. End-users and installers must be provided with antenna installation instructions and transmitteroperating conditions for satisfying RF exposure compliance.FCC class AThis equipment has been tested and found to comply with the limits for a Class A digital device, pursuantto part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmfulinterference when the equipment is operated in a commercial environment. This equipment generates,uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruc-tion manual, may cause harmful interference to radio communications. Operation of this equipment in aresidential area is likely to cause harmful interference in which case the user will be required to correctthe interference at his own expense.Changes or modifications not expressly approved by the party responsible for compliance could void theuser’s authority to operate the equipment.6.4 EMC noticeGeneral informationNo specific requirement on the use of external cables or other accessories except power supply.K5903075 ST-150B 16/01/2014 23
6. Important informationWith the installation of the device, use only the delivered power supply or a spare part provided by thelegal manufacturer. Using another can result in a decrease of the immunity level of the device.Electromagnetic emissionsThe ST-150B is intended for use in the electromagnetic environment specified below. The customer orthe user of the ST-150B should assure that it is used in such an environment.Emissions test Compliance Electromagnetic environment –GuidanceRF emissionsCISPR 11Group 1 The ST-150B uses RF energyonly for its internal function.Therefore, its RF emissions arevery low and are not likely tocause any interference in nearbyelectronic equipment.RF emissionsCISPR 11Class AHarmonic emissionsIEC 61000-3-2Class DVoltage fluctuations/ flickeremissionsIEC 61000-3-3CompliesThe ST-150B is suitable for usein all establishments, includingdomestic establishments andthose directly connected to thepublic low-voltage power supplynetwork that supplies buildingsused for domestic purposes.This ST-150B complies with appropriate medical EMC standards on emissions to, and interference fromsurrounding equipment. Operation is subject to the following two conditions: (1) this device may not causeharmful interference, and (2) this device must accept any interference received, including interference thatmay cause undesired operation.Interference can be determined by turning the equipment off and on.If this equipment does cause harmful interference to, or suffer from harmful interference of, surroundingequipment, the user is encouraged to try to correct the interference by one or more of the following mea-sures:• Reorient or relocate the receiving antenna or equipment.• Increase the separation between the equipment and receiver.• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.• Consult the dealer or an experienced technician for help.Electromagnetic immunityThe ST-150B is intended for use in the electromagnetic environment specified below. The customer orthe user of the ST-150B should assure that it is used in such an environment.Immunity test IEC 60601Test levelsCompliance level Electromagneticenvironment –guidanceElectrostatic discharge(ESD)IEC 61000-4-2± 6kV contact±8kVair± 6kV contact±8kVairFloors should be wood,concrete or ceramic tile.If floors are covered withsynthetic material, therelative humidity shouldbe at least 30%Electrical fasttransient/burstIEC 61000-4-4± 2kV for power supplylines± 1kV for input/ outputlines± 2kV for power supplylines± 1kV for input/ outputlinesMains power qualityshould be that of a typicalcommercial or hospitalenvironment24 K5903075 ST-150B 16/01/2014
6. Important informationImmunity test IEC 60601Test levelsCompliance level Electromagneticenvironment –guidanceSurgeIEC61000-4-5± 1 kV line(s) to line(s)± 2 kV line(s) to earth± 1 kV line(s) to line(s)±2kVline(s)toearthMains power qualityshould be that of a typicalcommercial or hospitalenvironmentVoltage dips, shortinterruptions and voltagevariations on powersupply input linesIEC 61000-4-11<5%UT1(> 95% dip inUT) for 0.5 cycle40% UT(60%dipinUT)for 5 cycles70% UT(30%dipinUT)for 25 cycles<5%UT(>95% dip inUT) for 5s<5%UT(> 95% dip inUT) for 0.5 cycle40% UT(60% dip in UT)for 5 cycles70% UT(30% dip in UT)for 25 cycles<5%UT(>95% dip inUT)for5sMains power qualityshould by that of a typicalcommercial or hospitalenvironment. If theuser of the ST-150Brequires continuedoperation during powermains interruptions, it isrecommended that theST-150B be poweredfrom an uninterruptiblepower supply or a battery.Power frequency (50/60Hz) magnetic fieldIEC 61000-4-83A/m Not applicable Power frequencymagnetic fields shouldbe at levels characteristicof a typical location ina typical commercial orhospital environment.Conducted RFIEC 61000-4-6Radiated RFIEC 61000-4-33Vrms150 kHz to 80 MHz3V/m80 MHz to 2.5 GHz3V3V/mPortable and mobileRF communicationsequipment should beused no closer to anypart of the ST-150B,including cables, thanthe recommendedseparation distancecalculated from theequation applicableto the frequencyof the transmitter.Recommendedseparation distanced=1.2√Pd=1.2√P80 MHz to 800MHzd=2.3√P800 MHz to 2.5GhzWhere P is the maximumoutput power ratingof the transmitter inwatts (W) accordingto the transmittermanufacturer and dis the recommendedseparation distance inmeters (m).Field strengths fromfixed RF transmitters,as determined by an1. is the a.c. mains voltage prior to application of the test level.K5903075 ST-150B 16/01/2014 25
6. Important informationImmunity test IEC 60601Test levelsCompliance level Electromagneticenvironment –guidanceelectromagnetic sitesurvey,2should be lessthan the compliancelevel in each frequencyrange.3Interference may occur inthe vicinity of equipmentmarked with symbol:At 80 MHz and 800 MHz, the higher frequency range applies.These guidelines may not apply in all situations. Electromagnetic propagation is af-fected by absorption and reflection from structures, objects and people.Recommended separation distanceThe ST-150B is intended for use in an electromagnetic environment in which radiated RF disturbancesare controlled. The customer of the user of the ST-150B can help prevent electromagnetic interferenceby maintaining a minimum distance between portable and mobile RF communications equipment (trans-mitters) and the ST-150B as recommended below, according to the maximum output power of the com-munications equipment.Separation distance according to frequency of transmitterRated maximum outputpower of transmitter 4W150kHz to 80MHzd=1.2√P80MHz to 800MHzd=1.2√P800MHz to 2.5GHzd=2.3√P0.01 0.12 0.12 0.230.1 0.38 0.38 0.731 1.2 1.2 2.310 3.8 3.8 7.3100121223At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.2. Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateurradio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagneticenvironment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in thelocation in which the ST-150B is used exceeds the applicable RF compliance level above, the ST-150B should be observed to verifynormal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocatingthe ST-150B.3. Over the frequency range 150 kHz to 80 MHz, field strengths should be less than3V/m.4. For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can beestimated using the equation applicable to the frequency of the transmitter. Where P is the maximum output power rating of thetransmitter in watts (W) according to the transmitter manufacturer.26 K5903075 ST-150B 16/01/2014
6. Important informationThese guidelines may not apply in all situations. Electromagnetic propagation is af-fected by absorption and reflection form structures, object and people.6.5 Explanation of symbolsSymbols on the deviceOn the device or power supply, you may find the following symbols (nonrestrictive list):Indicates the device meets the requirements of the applicable EC directives.Indicates compliance with Part 15 of the FCC rules (Class A or Class B)Indicates the device is approved according to the UL Recognition regulationsIndicates the device is approved according to the UL Demko regulationsIndicates the device is approved according to the CCC regulationsIndicates the device is approved according to the VCCI regulationsIndicates the device is approved according to the KC regulationsIndicates the device is approved according to the BSMI regulationsIndicates the USB connectors on the deviceIndicates the DisplayPort connectors on the deviceIndicates the manufacturing dateIndicates the temperature limitations5for the device to safely operate within specs.5. Values for xx and yy can be found in the technical specifications paragraph.K5903075 ST-150B 16/01/2014 27
6. Important informationIndicates the device serial noWarning: dangerous voltageCautionConsult the operating instructionsIndicates this device must not be thrown in the trash but must be recycled,according to the European WEEE (Waste Electrical and Electronic Equipment)directiveIndicates Direct Current (DC)Indicates Alternating Current (AC)Stand-bySymbols on the boxOn the box of the device, you may find the following symbols (nonrestrictive list):Indicates a device that can be broken or damaged if not handled carefully whenbeing stored.Indicates a device that needs to be protected from moisture when being stored.Indicates the storage direction of the box. The box must be transported, handledand stored in such a way that the arrows always point upwards.15ornIndicates the maximum number of identical boxes which may be stacked on eachother, where “n” is the limiting number.20 - 30 KgIndicates that the box should be carried with two persons.Indicates that the box should not be cut with a knife, a cutter or any other sharpobject.-20 °C+60 °CxxyyIndicates the temperature limits6to which the device can be safely exposed whenbeing stored.28 K5903075 ST-150B 16/01/2014
6. Important information85 %5 %xyy Indicates the range6of humidity to which the device can be safely exposed whenbeing stored.106 kPa50 kPaxxyyy Indicates the range6of atmospheric pressure to which the device can be safelyexposed when being stored.6.6 Legal disclaimerDisclaimer noticeAlthough every attempt has been made to achieve technical accuracy in this document, we assume noresponsibility for errors that may be found. Our goal is to provide you with the most accurate and usabledocumentation possible; if you discover errors, please let us know.Barco software products are the property of Barco. They are distributed under copyright by Barco N.V. orBarco, Inc., for use only under the specific terms of a software license agreement between Barco N.V. orBarco Inc. and the licensee. No other use, duplication, or disclosure of a Barco software product, in anyform, is authorized.The specifications of Barco products are subject to change without notice.TrademarksAll trademarks and registered trademarks are property of their respective owners.Copyright noticeThis document is copyrighted. All rights are reserved. Neither this document, nor any part of it, maybe reproduced or copied in any form or by any means - graphical, electronic, or mechanical includingphotocopying, taping or information storage and retrieval systems - without written permission of Barco.© 2014 Barco N.V. All rights reserved.6.7 Technical specificationsTechnical specifications for the ST-150BDisplay LED, 15" SXGA (1024 x 768)Processor Intel Atom Cedar Trail D2550 – 1.86 GhzSystem chip set Intel NM10BIOS AMI 16M-bit SPI UFEI BIOSRTC battery CR2032Storage Optional 2.5” HDD or SSD (Standard - no storage installed)Required rating: 5Vdc, max 2AHDD drive 320 GB (optional)SSD drive 8, 16, or 32 GB (optional)6. Values for xx and yy can be found in the technical specifications paragraph.K5903075 ST-150B 16/01/2014 29
6. Important informationSystem memory DDR3 10662or4GBOperating system LinuxWindows® XP EmbeddedWindows® XP Professional for Embedded SystemsWindows® 7 EmbeddedConnectivity LAN (x1)USB 2.0 (x4)Headphone jack (x2)Microphone jack (x1)Handset connectorDVI outProgrammable GPIOService Call (optional)User interface 5-wire resistive touch-screenOn screen keyboardMembrane keypadOn/Off switchLED call warning lightsWebcam Integrated, with privacy shutterHD720PAudio 2 off 2 Watt integral speakersInternal microphoneWarning / ring tonesMedical EnvironmentConsiderationsAntibacterial coatingFanless coolingCertifications EN/UL60601, FCC-Class A, CE??????????????????Power requirements 19V DC, 4.74ADevice is intended to be supplied with a PSU with rated output of 19V,4.74A,Dimensions (mm) 384 x 354 x 70 (without handset, MSR)Weight 4.0 kgInternal optionsSmart Card Reader (SCR) √Combined SCR and RFIDreader√WiFi Mini PCe 802.11b/g/n Wireless LAN ModuleBluetooth USB Bluetooth ModuleExternal optionsAnalogue handset √30 K5903075 ST-150B 16/01/2014
6. Important informationMagStripe Reader (MSR) √(right side only)Wired remote (RIMO) √Headphone hanger √Operating temperature 0°C to 40°CStorage & transporttemperature-20°C to 60°COperating humidity 20% - 90% (non-condensing)Storage & transport humidity 10% - 80% (non-condensing)Operating atmosphericpressure50 - 106 kPaStorage and transportatmospheric pressure50 - 106 kPaK5903075 ST-150B 16/01/2014 31

Navigation menu