Banner Engineering QT50RUS Field Disturbance Sensor User Manual users manual

Banner Engineering Corporation Field Disturbance Sensor users manual

users manual

Printed in USA            08/06   P/N 124617 rev. CR-GAGE™ QT50R Series SensorRadar-Based Vehicle Detection SensorWARNING . . .  Not To Be Used for Personnel ProtectionNever use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death.These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Consult your current Banner Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for personnel protection.Features•   Reliably detects vehicles and trains based on frequency-modulated continuous-wave (FMCW) radar technology•   Detects objects up to 7.2 m (24') away using a fixed background reference target up to 8 m (26') away•  Detection is unaffected by wind or changing air temperatures•  Easy to set up using sealed push button or remote wire•   Operates in Industrial, Scientific, and Medical (ISM) telecommunication band; no special license required• 15 to 30V dc operation•  Rugged IP67 housing for harsh environmentsModelsModels* Sensing Range Cable Telecom Approval OutputQT50RObjects: 0.5 to 7.2 m (1.6' to 24')Background: 4 to 8 m (13' to 26')5-wire, 2 m (6.5') cable ETSI/EN 300 440 (EU except UK and France)Bipolar NPN and PNPQT50RQ 5-pin Euro-style integral QDQT50RUS 5-wire, 2 m (6.5') cable FCC Part 15 (USA)QT50RUSQ 5-pin Euro-style integral QD* For 9 m cable, add suffix “W/30” to the model number of the cabled sensor (e.g., QT50R W/30). A QD model requires a mating cable. See page 7.
R-GAGE™ QT50R Series Sensors2   P/N 124617 rev. C Banner Engineering Corp. • Minneapolis, MN U.S.A.www.bannerengineering.com  •  Tel: 763.544.3164Figure 1. R-GAGE featuresOverviewThe R-GAGE sensor emits high-frequency radio waves from an internal antenna, which forms a well-defined beam. Some of this emitted energy is reflected back to the receiving antenna. Signal processing electronics determine the distance from the sensor to the vehicle based on the time delay of the return signal. The sensor is configured to operate like a retroreflective photoelectric sensor. See Figure 3.Figure 3.  Threshold automatically placed at 90% of distance to background target that is taughtNOTE:  The MODE button on this model is not functional.Background Range 4 to 8 m (13' to 26')Dead Zone 0.5 m (1.6')Background TargetDetection Range 0.5 to 7.2 m (1.6' to 24') R-GAGE Sensor  (not shown to scale)Threshold Range (90% of Taught Background Range)Threshold45° 45°Figure 2. R-GAGE field of view
R-GAGE™ QT50R Series Sensors    P/N  124617 rev. C    3 Banner Engineering Corp. • Minneapolis, MN U.S.A.www.bannerengineering.com  •  Tel: 763.544.3164Sensor Programming1.  Mount the sensor securely. Align the sensor with the background target, making the face of the Sensor as parallel as possible to the background target.   In programming mode (only after the TEACH push button is pressed), the red Signal LED will flash faster as the alignment improves; solid ON is best. If the red Signal LED does not flash, then the background target is not sufficient and a different target must be used, such as a metal plate or a corner cube reflector.2.  Verify that the area between the sensor and the background is clear, and follow the programming procedure in the table below.General Notes on Programming•   Once the sensor enters TEACH mode, it will default to the previous settings and exit TEACH mode after one minute.•   To exit TEACH mode and return to the previous settings, push and hold the TEACH push button (or pulse the remote line) for more than two seconds.4ProcedureResultPush Button Remote Line 0.02 sec. < T < 0.8 sec. Programming Mode•  Push and hold TEACH push button until Output LEDs turn ON Red•  No action required; sensor is ready to be aligned and programmedPower LED: OFF Output LEDs: ON Red Signal LED:  Flashes faster as background signal strength increases (i.e., as alignment improves); solid ON is bestTEACH Background Reference Target•  Press and release TEACH push button • Pulse the remote lineTeach AcceptedPower LED: ON Output LEDs: OFF Signal LED: ON solidTeach UnacceptablePower LED: OFF Output LEDs: ON Sensor defaults to program mode.
R-GAGE™ QT50R Series Sensors4   P/N 124617 rev. C Banner Engineering Corp. • Minneapolis, MN U.S.A.www.bannerengineering.com  •  Tel: 763.544.3164Figure 4. Setup for tunnel train detection4 to 8 m (13' to 26') YXSetup Procedure for Tunnel Train Detection1.  Mount the sensor such that Y is 1/3 of X, and align the sensor so the center of the beam strikes the corner of the tunnel beyond the far rail, as shown in Figure 4.2.  Make sure the area between the sensor and the background is clear, and press the TEACH button until the Output LEDs turn ON red. 3.  Align the sensor. The red Signal LED will flash faster as alignment improves; solid ON is best.4.  Press the TEACH button again. The Output LEDs turn OFF, and the red Signal LED turns ON.5. Verify proper setup by blocking the beam. The Output LEDs should turn ON yellow.
R-GAGE™ QT50R Series Sensors    P/N  124617 rev. C    5 Banner Engineering Corp. • Minneapolis, MN U.S.A.www.bannerengineering.com  •  Tel: 763.544.3164SpecificationsSpecifications are subject to change without notice.Range Sensor will detect a 1 m x 1 m metal plate at a distance of up to 7.2 m (24') when set up with a suitable background target.Detectable Objects Objects containing metal or other high-dielectric materialOperating Principle Frequency-modulated continuous-wave (FMCW) radar Operating Frequency 24.05 to 24.25 GHz, ISM Band (varies slightly with national telecom regulations)Supply Voltage 15 to 30V dcSupply Protection Circuitry Protected against reverse polarity and transient overvoltagesDelay at Power-up Less than 1.5 secondsOutput Configuration Bipolar NPN and PNP outputs, 150 mA (derate 1 mA per °C above 25° C)Output Protection Protected against short circuit conditionsIndicators Power LED: Green Signal Strength LED: Red Output LEDs: Yellow/Red See “Status Indicators” above.Adjustments TEACH programming button for setting background referenceOperating Temperature -20° to 55° C (-4° to 131° F)Environmental Rating IEC IP67; NEMA 6Connections 2 m (6.5') or 9 m (30') 5-conductor, shielded, PVC-jacketed attached cable or integral 5-pin Euro-style QDCertifications   and ETSI/EN 300 440 or FCC Part 15, depending on modelStatus IndicatorsPower LED IndicatesOFF Power is OFF.ON Green Power is ON.Signal LED IndicatesTEACH Mode (signal strength indicator for background)OFF Background target is not sufficient; use a different target.ON Red (flashing) Frequency of flash indicates alignment. LED flashes faster as alignment improves; solid ON indicates best alignment.RUN Mode (alignment indicator for background target taught)OFF Background target is not being sensed.ON Red (flashing) Frequency of flash is proportional to background target taught; solid ON indicates best alignment.Output LEDs IndicateON Red In TEACH mode.ON Yellow In RUN mode; target is sensed and outputs are conducting.CAUTION . . . Make No Modifications to this SensorAny modifications to this sensor not expressly approved by Banner Engineering could void the user’s authority to operate the sensor. Contact the Factory for more information.
R-GAGE™ QT50R Series Sensors6   P/N 124617 rev. C Banner Engineering Corp. • Minneapolis, MN U.S.A.www.bannerengineering.com  •  Tel: 763.544.3164HookupNOTES: • Cable and QD hookups are functionally identical.•  It is recommended that the shield wire be connected to earth ground or dc common. Shielded cordsets are recommended for all QD models.bkgybnbuwh+15 - 30V dcshield0 - 2V dcLoad 1Load 2Dimensions38.1 mm(1.50")46.1 mm(1.82")R45.0 mm(R1.77")66.0 mm(2.60")84.2 mm(3.31")33.0 mm(1.30")37.0 mm(1.46")74.1 mm(2.92")50.8 mm(2.00")50.8 mm(2.00")19.7 mm (0.78")37.0 mm(1.46")M30 X 1.5 ISO-6g4X Ø4.4 mm(Ø 0.17")34.2 mm(1.35")Cabled Models QD Models
R-GAGE™ QT50R Series Sensors    P/N  124617 rev. C    7 Banner Engineering Corp. • Minneapolis, MN U.S.A.www.bannerengineering.com  •  Tel: 763.544.3164Mounting BracketsQuick-Disconnect (QD) Cables Style Model Length Dimensions Pinout5-Pin Euro-style Straight with shieldMQDEC2-506 MQDEC2-515 MQDEC2-5302 m (6.5') 5 m (15') 9 m (30')5-Pin Euro-style Right-angle with shieldMQDEC2-506RAMQDEC2-515RA MQDEC2-530RA2 m (6.5') 5 m (15') 9 m (30')SMB30SC•   30 mm split clamp with swivel, black reinforced thermoplastic polyester•   Stainless steel hardware includedSMB30MM•   30 mm, 11-gauge, stainless steel bracket with curved mounting slots for versatile orientation•   Clearance for M6 (1/4") hardware50.8 mm(2.00")58.7 mm(2.31")66.5 mm(2.62")30.0 mm(1.18")30 x 1.5 mminternal thread29.0 mm(1.14")12.7 mm(0.50")35.1 mm(1.38")35.1 mm(1.38")69.9 mm(2.75")7.1 mm0.28 x 90 (2 Slots)R 25.4 mm(1.00")ø30.1 mm(1.19")57.2 mm(2.25")25.4 mm(1.00")25.4 mm(1.00")ø 6.4 mm(0.25" dia.)57.2 mm(2.25")M12 x 1ø 15 mm(0.6")44 mm max.(1.7")38 mm max.(1.5")M12 x 1ø 15 mm(0.6")38 mm max.(1.5")White WireBlue WireBlack WireBrown WireGray Wire
R-GAGE™ QT50R Series SensorsBanner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN USA 55441 • Phone: 763.544.3164 • www.bannerengineering.com • Email: sensors@bannerengineering.comP/N 124617 rev. CWARRANTY:  Banner Engineering Corp. warrants its products to be free from defects for one year. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period. This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any other warranty either expressed or implied.

Navigation menu