Banner Engineering Q120RAUS R-Gage Radar Sensors User Manual

Banner Engineering Corporation R-Gage Radar Sensors

User Manual

Rhein Tech Laboratories, Inc. Client:  Banner Engineering, Inc. 360 Herndon Parkway Model:  Q120RA-US Suite 1400 Standard:  FCC 15.245 Herndon, VA 20170    FCC ID:  UE3Q120RAUS http://www.rheintech.com Report #:  2012355   Page 21 of 27  Appendix H:  Manual  Please refer to the following pages.
Radar-Based Dual-Zone Narrow-Beam Sensors for Detection of Moving and Stationary TargetsFor complete technical information about this product, including dimensions, accessories, and specifications, see www.BannerEngineering.com and search 157494_web  CAUTION: Make No Modifications to this ProductAny modifications to this product not expressly approved by Banner Engineeringcould void the user's authority to operate the product. Contact the Factory formore information.WARNING: Not To Be Used for Personnel ProtectionNever use this product as a sensing device for personnel protection. Doingso could lead to serious injury or death. This product does NOT include the self-checking redundant circuitry necessary to allow its use in personnel safety applica-tions. A sensor failure or malfunction can cause either an energized or de-energizedsensor output condition.ModelsModel SensingRangeConnection Supply Voltage Telecom Approval OutputQ120RA-US-AF2 Two independ-ent sensingzones; 1 to 40+meters (131 ft)5-wire 2 m (6.5 ft)Integral cable 12 to 30V dcPending approval for United StatesDIP-switch-selectable NPN orPNP; N.O. or N.C.Q120RA-EU-AF2 Pending approval for Europe (exceptUK) and ChinaQ120RA-UK-AF2 Pending approval for UKCabled models only are listed. For integral 5-pin Euro-style (M12) quick-disconnect fitting, add suffix "Q" to the model number (e.g., Q120RA-xx-AF2Q). *QD modelsrequire a mating cordset.Sensor ConfigurationThe sensitivity, and output configuration can be selected via the DIP switches on the side of the sensor.Use the included spanner to open the screw-off cover on the side of the sensor and access the DIP switches.Important: Tighten the DIP switch cover a full quarter turn after contact to maintain the watertight seal.DIP Switch FunctionsSwitches FunctionA1, A2, A3, A4 Zone 1 Distance (detects objects from sensor face to this point)A5, A6, A7 Zone 2 Distance, Offset from Zone 1A8 PolarityB1, B2, B3 Sensitivity (higher sensitivity sees weaker objects and has a larger beam pattern)B4, B5, B6 Response SpeedB7 Normally Open/Normally Closed output functionalityB8 Not UsedDIP switch 1 is on the left and DIP switch 8 is on the right.R-GAGE™ Q120RA-AF2 Sensor    P/N 157494 Rev. C8/21/20120 157494 8
Distance Settings* Default settingsZone 1 DistanceA1 A2 A3 A4DistanceEU US, UK0 0 0 0 2 m (6.6 ft) 3.5 m (11.5 ft)0 0 0 1 2.5 m (8.2 ft) 4 m (13.1 ft)0 0 1 0 3 m (9.8 ft) 4.5 m (14.8 ft)0 0 1 1 3.5 m (11.5 ft) 5 m (16.4 ft)0 1 0 0 4 m (13.1 ft) 5.5 m (18.0 ft)0 1 0 1 5 m (16.4 ft) 6 m (19.7 ft)0 1 1 0 6 m (19.7 ft) 6.5 m (21.3 ft)0 1 1 1 7 m (23.0 ft) 7 m (23.0 ft)1* 0* 0* 0* 8 m (26.2 ft) 8 m (26.2 ft)1 0 0 1 10 m (32.8 ft) 10 m (32.8 ft)1 0 1 0 12 m (39.4 ft) 12 m (39.4 ft)1 0 1 1 14 m (45.9 ft) 14 m (45.9 ft)1 1 0 0 16 m (52.5 ft) 16 m (52.5 ft)1 1 0 1 20 m (65.6 ft) 20 m (65.6 ft)1 1 1 0 25 m (82.0 ft) 25 m (82.0 ft)1 1 1 1 30 m (98.4 ft) 30 m (98.4 ft)Zone 2 Distance Offset from Zone 1A5 A6 A7 Offset0 0 0 2 m (6.6 ft)0 0 1 4 m (13.1 ft)0 1 0 6 m (19.7 ft)0* 1* 1* 8 m (26.2 ft)1 0 0 10 m (32.8 ft)1 0 1 15 m (49.2 ft)1 1 0 20 m (65.6 ft)1 1 1 25 m (82.0 ft)NOTE: Highest sensitivity is achieved only if the sensing distance is 36 m (118.1 ft) or less.    R-GAGE™ Q120RA-AF2 Sensor2 www.bannerengineering.com - tel: 763-544-3164 P/N 157494 Rev. C
Sensitivity Selection* Default settingsB1 B2 B3 Sensitivity0* 0* 0* 8 (Highest)0 0 1 7...0 1 0 6 (High)0 1 1 5...1 0 0 4 (Medium)1 0 1 3...1 1 0 2 (Low)1 1 1 1 (Lowest)NOTE: Operation at a high sensitivity not guaranteed for a zone set beyond 45 m (147.6 ft)Response Speed* Default settingsB4 B5 B6 ON Total OFF Total Total0 0 0 15 15 300 0 1 30 70 1000 1 0 30 120 1500* 1* 1* 50 300 3501 0 0 50 600 6501 0 1 30 1000 10301 1 0 120 600 7201 1 1 120 6000 6120Output Configuration* Default settingsA8 NPN / PNP0* NPN1 PNPB7 Normally Open / Closed0* NO1 NCR-GAGE™ Q120RA-AF2 Sensor    P/N 157494 Rev. Cwww.bannerengineering.com - tel: 763-544-3164 3
SpecificationsRangeThe sensor is able to detect a proper object (see Detectable Objects)from 1 to 40+ m (3.3 to 131.2+ ft), depending on targetDetectable ObjectsObjects containing metal, water, or similar high-dielectric materialsOperating PrincipleFrequency modulated continuous-wave (FMCW) radarOperating Frequency24.00 to 24.25 GHz, ISM Band (varies slightly with model, depending onnational telecom regulations)Supply Voltage12 to 30V dc, less than 100 mA, exclusive of loadSupply Protection CircuitryProtected against reverse polarity and transient overvoltagesDelay at Power-upLess than 2 secondsOutput ConfigurationDIP-Switch A8 selects Dual NPN (default) or PNP; DIP-Switch B7 se-lects N.O. (default) or N.C. operation; 150mA each•Zone 1 output: white wire•Zone 2 output: black wireOutput ProtectionProtected against short circuit conditionsResponse TimeDIP-Switch-configurable ON/OFF response timeIndicatorsPower LED: Green (power ON)Signal Strength LED: Red, flashes in proportion to signal strength.Steady on at 4x excess gain. Only indicates signal amplitude, not targetdistance.Output LEDs: Yellow (output energized) / Red (configuration)AdjustmentsDIP-switch-configurable sensing distance, sensitivity, response time, andoutput configurationConstructionHousing: ABS/polycarbonateLightpipes: AcrylicAccess Cap: PolyesterOperating Temperature– 40° to + 65° C (– 40° to + 149° F)Environmental RatingIP67ConnectionsIntegral 5-wire 2 m (6.5 ft) cable or M12 Euro-style QD fitting. QD modelsrequire a mating cordsetCertificationsTelecom approvals pendingWindowsThe R-GAGE sensor can be placed behind a glass or a plastic window, but the configuration must be tested and the distance from the sensor to the window must bedetermined and controlled prior to installation. There is typically a 20% signal reduction when the sensor is placed behind a window.Polycarbonate at 4mm thickness performs well in most situations, but the performance depends on filler materials. Thinner (1 to 3 mm) windows have high reflection. Theamount of reflection depends on the material, thickness, and distance from the sensor to the window.Locate the sensor in a position of minimum reflection from the window, which will repeat every 6.1 mm of distance between the sensor and the window. The positions ofmaximum reflection from the window repeat between the minimums, and decrease in effect until the window is approximately 150 mm (5.9 in) away. Consult the factory forpre-tested window materials which can be used at any distance without issue.Additionally, the face of the window should be protected from flowing water and ice by use of a flow diverter or hood directly above the window. Falling rain or snow in theair in front of the window, light water mist, or small beads on the face of the window are typically not an issue. However, a thick, continuous surface of water or ice directlyon the face of the window can be detected as a dielectric boundary.Hookupshield (QD cordset)3124512-30V dcLoad 1Load 2+–Wiring Key:1 = Brown2 = White3 = Blue4 = Black5 = Gray (Do not connect)NOTE: Banner recommends that the shield wire (QD cordsets only) be connected to earth ground or dc common. Shielded cordsets arerecommended for all QD models.    R-GAGE™ Q120RA-AF2 Sensor4 www.bannerengineering.com - tel: 763-544-3164 P/N 157494 Rev. CFCC ID: UE3Q120RAUS—This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmfulinterference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Banner Engineering Corp Limited WarrantyBanner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp.will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warrantyperiod. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION,ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE,COURSE OF DEALING OR TRADE USAGE.This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BELIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSE-QUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARIS-ING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any productpreviously manufactured by Banner Engineering Corp.    R-GAGE™ Q120RA-AF2 Sensor