BQT Solutions MIP5 Contactless Smartcard Reader User Manual APPENDIX K INS Man

BQT Solutions (Australia) Pty Ltd Contactless Smartcard Reader APPENDIX K INS Man

users manual

FCC ID: QVL-MIP5                                                                                              Page 1 of 7EMC Technologies Pty Ltd 3/87 Station Rd Seven Hills NSW 2147 Australia Tel: +61 2  9624 2777  Fax: +61 2  9838 4050APPENDIX JINSTALLATION MANUAL
For further information or to find out more about our range of smart card and biometric solutions, visit BQT Solutions on the web at:www.bqtsolutions.comAlternatively you can contact us at one of our global locations.mmiiP5MIFARE PROXIMITY READERINSTALLATION GUIDEmiP5- Wiegand UnitVersion 1.1 Designed & Manufactured in AustraliaAUSTRALIA & ASIA PACIFIC UNITED KINGDOM & EMEALevel 4, 65 Epping Road Global House,1 Ashley Avenue, EpsomNorth Ryde NSW 2113 Australia Surrey  KT 18  5AD United Kingdomphone: +61 (0)2 8817 2800      phone:  + 44 (0)20 8823 9350             fax: +61 (0)2 8817 2811 fax: + 44 (0)20 8823 9001email:  info@bqtsolutions.com email: info@bqtsolutions.co.ukAMERICAS CHINA15030 Ventura Blvd., Ste. 19-798 Suite 1208-1209, Offshore Oil TowerSherman Oaks, CA 91403 583 LingLing Rad, ZuHui DistrictUnited States of America Shanghai, P.R. CHINA 20030phone: +1 818 994 6888                     phone: +86 (21) 5425 5935 fax: +1 818 994 0225 fax: +86 (21) 5425 5936email: infousa@bqtsolutions.com   email: china@bqtsolutions.com For Technical Support, email:techsupport@bqtsolutions.comNOTE: Information contained in this document is subject to change without notice.Copyright © 2004 BQT Solutions Limited. All rights reserved.BQT Solutions and the BQT Solutions logo are registered trademarks of BQT Solutions (Australia) Pty Ltd. Mifare is a registered trademark of Philips Electronics.miP5_8wire_v1.1: Last revised April 2005
WIRING SCHEMATICNOTE: The 0V or GND reference cable shall be included within the controller cable. The 12Vdc power cable shall NOT be included in the controller Cable.REGULATORY INFORMATIONCE MarkThe miP5 has passed all relevant tests and obtained CE approval. C TickThe miP5 has passed all relevant requirements for application of C Tick.FCCThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) thisdevice must accept any interference received, including interference that may cause undesired operation.NOTE:This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to providereasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installedand used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in aparticular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, theuser is encouraged to try to correct the interference by one or more of the following measures:- Reorient or relocate the receiving antenna- Increase the separation between the equipment and receiver- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected- Consult the dealer or an experienced radio/TV technician for helpAny changes or modifications not expressively approved by BQT Solutions could void the user's authority to operate this equipment. Designed & Manufactured in AustraliaRED +12VdcBLACK GNDYELLOW BUZORANGE LEDGREEN W0WHITE W1BROWN/W* T1BROWN/W* T2GNDBUZLEDReaderConnectionPowerSupplyController+12Vdc0VPower CableController CableW0NOTE: If used with a shielded cable, the shield is connected to Building GND.W1* Tamper cable connection is optional.INTRODUCTIONThank you for purchasing the miP5 Mifare®Contactless Smart Card Proximity Reader.The miP5 is used in security applications and interfaces into Wiegand applications. The miP5 is preset with BQT’s proximity 'Keys' and valid smart cards are issued with corresponding 'Keys' thusensuring that the system cannot be compromised.The reader incorporates a LED to provide feedback to a person wishing to enter. The LED is controlled by the securitysystem.The miP5 is low profile and can be installed in new installations or as an upgraded reader in existing proximityaccess control systems.INSTALLATIONRemove the cover by holding the unit by the rim and pushing the reader out with your thumbs.- 1 - - 10 -
If necessary, drill holes for the mounting screws in the wall or mounting box on which the reader unit will beplaced. Use the template provided.1. Place the controller and power supply cable through the Grommit hole.2. Drill the holes as indicated by the arrows.NOTE:  Make sure that you don't drill through the cable.Check your circuit diagram for the colour coding of the circuit wiring. The reader can be damaged beyond repair ifthe wiring is connected incorrectly. Read the instructions on the next page first.**NNOOTTEE::Tamper cable connection is optional.3030WARRANTYThe miP5 comes with a 5 year warranty from the date of dispatch from BQT Solutions. The warranty is void if theinstructions contained within this manual have not been adhered to. See the BQT Solutions website for further termsand conditions.SPECIFICATIONSReader Output  Wiegand  Power requirements  12Vdc Current Consumption    Normal  110mA  Activated  120mA Read range  20 - 60mm (0.8” – 2.4”)(typically) Operating temperature  -10ºC to +55ºC (14ºF to 131ºF) Relative humidity  90% max, operating non-condensing Reader dimensions  90mm x 90mm x 20mm (3.54" x 3.54" x 0.79") Status LED’s  Green and Red Audible tone  Tone on matching software key and wired external buzzer control Colour  Charcoal & Ivory IP rating  IP 67 Wall ViewRED +12VdcBLACK GNDYELLOW BUZORANGE LEDGREEN W0WHITE W1BROWN/W* TAMPER1BROWN/W* TAMPER2- 9 - - 2 -
EXTERNAL USEMount the reader on a suitable external single gang surface mount box.Make sure that the wire bundle to the miP5 has an IP rating of at least IP67.Use warming pads if the temperature of the reader is expected to fall below -10ºC (14ºF).HANDLINGHandle the miP5 with care. Do not damage/drop unit before installation. The reader unit will not be waterproof if the casing is damaged. Replace the reader if the casing is damaged.MAINTENANCEOnce installed the miP5 requires no maintenance. TROUBLESHOOTINGIf the reader doesn't respond when a valid smart card is presented, check the following.If the problem still exists then uninstall the reader and send it back to BQT Solutions (address details on the backof this manual). If the reader is within the warranty period then another will be sent free of charge. Symptom  Possible cause  Check  LED is not lit  No power to the reader  Check the power supply to the reader. LED is Orange or Buzzer sounds low  Voltage to the reader is below 10V  Check the power supply to the reader Reader doesn’t respond  Invalid card or card is faulty  Check reader with another valid smartcard Wiring to the controller faulty.  Check the wiring to the controller  Reader beeps but lock doesn’t open NOTE: If reader beeps when a valid smart card is presented then the reader is functioning. 1. Connect the 0V Reference and 0V (if provided in the power supply) to Ground (GND).2. Connect the Wiegand signal cables.3. Connect the Buzzer and the LED cables.4. Attach the 12Vdc wire last.OPTIONAL: Connect the Tamper cables.5. Place the reader on the wall (Make sure the wires are not crushed)6. Insert and hand tighten the screws.7. Check that the reader is level before tightening the screws.NOTE:  Excessive tightening of screws may deform the casing, resulting in a damaged unit. THIS WILL VOID THE WARRANTY.8. Replace the cover.9. Power up the reader.NOTE: The unit needs approximately 13 seconds to set up before it can respond to a valid smart card.!If the reader has the same power supply as the door latch relay, make sure that the relayis protected by a fast Schottky diode (Part number: Philips BYV10-20). If the relay is notprotected reader operation will be affected.- 3 - - 8 -
DRILLING TEMPLATEFOR miP5Carefully remove this middle section of themanual to use as a drilling guide.THIS PAGE LEFT BLANKINTENTIONALLY- 4 -- 7 -
DRILLING TEMPLATEFOR miP520mm (0.79”) hole for wire entry2mm x 4 mm (0.08” x 0.16”) holes for mounting screwsMinimum outer dimension is90 mm x 90 mm (3.54” x 3.54”) so as not to interfere with any other components- 5 - - 6 -