BQT Solutions BT900A CONTACTLESS SMARTCARD READER User Manual USERS MANUAL

BQT Solutions (Australia) Pty Ltd CONTACTLESS SMARTCARD READER USERS MANUAL

USERS MANUAL

 Page 1 of 3   EMC TechnologiesABN 82 057 105 549 Unit 3/87 Station Road Seven Hills NSW 2147 Au Telephone      +61 2 9624Facsimile       +61 2 9838Email         syd@emctechwww.emctech.com.au  Melbourne 57 Assembly Drive Tullamarine Vic 3043 Tel:   +61 3 9335 3333 Fax:  +61 3 9338 9260 Sydney Unit 3/87 Station Road Seven Hills NSW 2147 Tel:   +61 2 9624 2777 Fax:  +61 2 9838 4050 Brisbane 1/15 Success Street Acacia Ridge Qld 4110 Tel:   +61 7 3875 2455 Fax:  +61 7 3875 2466 Auckland (NZ) 47 MacKelvie Street Grey Lynn Auckland Tel:   +64 9 360 0862 Fax:  +64 9 360 0861        APPENDIX L OF TEST REPORT T 60822_F   USER MANUAL     FCC ID:  QVL-BT900A Manufacturer:  BQT Solutions (Australia) Pty Ltd Test Sample:  Contactless Smart Card Reader Model:   BT900-WG Serial Number:  None   Date:  4th September 2006
9 series_v2.9 Sep06 Drilling Template  Copyright © 2006 BQT Solutions Limited. BQT Solutions and the BQT Solutions logo are registered trademarks of BQT Solutions (Australia) Pty Ltd.   Mifare is a registered trademark of Philips Electronics.   Specifications Output protocols   Wiegand 26-199 bit, RS485 or custom configurations (model dependent)   Power requirements  12Vdc Current consumption       Normal   120mA   Activated   140mA  Read range   20 - 60mm (0.8” – 2.4”)(typically)  Operating temperature   -25ºC to +65ºC (-13ºF to 149ºF)  Relative humidity   90% max, operating  non-condensing Reader dimensions  140mm (L) x 45mm (W) x 32mm (D) (5.51” x 1.77” x 1.26”) Status LED’s   Green & Red Audible tone   Internal or external buzzer control Colour   Two toned – Silver & Charcoal IP rating   IP 67  Information contained in this document is subject to change without notice.  For further technical information visit our website at www.bqtsolutions.com or email techsupport@bqtsolutions.com.   Alternatively contact us at one of our global locations UNITED KINGDOM & EMEA Global House, 1 Ashley Avenue, Epsom Surrey KT 18 5AD United Kingdom Phone: + 44 (0)20 8823 9350  Fax: + 44 (0)20 8823 9001  AMERICA 30021 Tomas Street, Suite 300 Rancho Santa Margarita CA 92688 United States of America Phone: +1 877 278 2637 (ext 42)  Fax:+1 877 278 2637  AUSTRALIA & ASIA PACIFIC Level 4, 65 Epping Road North Ryde NSW 2113 Australia Phone: +61 (0)2 8817 2800 Fax: +61 (0)2 8817 2811  CHINA  Suite 1602, No.75, ShengDa Garden, 2518 LongHua Road,   XuHui District, Shanghai 200232, P.R.China  Tel: +86-21-5407 3638 Fax: +86-21-5407 3738  DF900 - DESFire BT900 - Mifare  miP9 - SPEK CSN9 - Card Serial Number miPASS 9 Series Mifare  reader models For all 9 Series readers ●  20mm (0.79”) diameter   hole for wire entry ●  2 x 4 mm  (0.16”) diameter   holes for mounting screws ●  Minimum reader dimensions    are 140mm x 45 mm   (5.51" x 1.77")  INSTALLATION GUIDE Version 2.9Regulatory InformationCE MarkThe 9 Series has passed all relevant tests and obtained CE approval. C TickThe 9 Series has passed all relevant requirements for application of C Tick.FCCThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.BT900D, BT900DG, DF990D, DF900DG    FCC ID: QVL - BT900PBT900WG      FCC ID: QVL -BT900AmiP9, CSN9, BT900W  FCC ID: QVL MIP9NOTE:This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:- Reorient or relocate the receiving antenna- Increase the separation between the equipment and receiver- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected- Consult the dealer or an experienced radio/TV technician for helpAny changes or modifications not expressively approved by BQT Solutions could void the user's authority to operate this equipment. Designed & Manufactured in AustraliaNOTE:   The 0V reference cable shall be included within the controller cable.   The 12Vdc power cable shall NOT be included in the controller Cable.   Only ONE power source is connected from the reader at any one time.   RS485 - OPTIONAL USE  45mm  62mm  ➣ ➣ ➣ ➣ 20mm Ø 4mm Ø 4mm Ø Wiring Schematic Reader connectionsBUZLEDW0W1+12Vdc 0VPower CableController CableRED  +12VdcBLACK 0VYELLOW BUZORANGE  LEDGREEN  W0WHITE  W1YELLOW/WGREEN/WBT900W, BT900WGmiP9, CSN9RS485ARS485BPower SupplyControllerNOTE: If used with a shielded cable, the shield is connected to Controller 0V referenceDF900D, DF900DG, BT900D, BT900DG0V9 series_v2.9.ai   21/09/2006   10:26:36 AM
WALL VIEW(not to scale)IntroductionThank you for purchasing a miPASS 9 Series Mifare Contactless Smart Card Reader.  Available in 4 different models catering for all security requirements large or small, whether your projects are price or functionality driven. The 9 Series reader models are: DF900 - DESFire BT900- Mifare (standard) miP9 - BQT SPEK CSN9 - Card Serial Number The 9 Series reader is used in security applications and interfaces into Wiegand applications. The 9 Series reader is preset with specific 'Keys'. Valid smart cards are issued with the same 'Keys'. This ensures that the system cannot be compromised. (No 'Keys" used for CSN9 model)The reader incorporates a LED and Buzzer to provide feedback to a person wishing to enter. The control of these is shared by the reader and security controller.The 9 Series reader is low-profile and can be installed in new installations or as an upgraded reader in existing proximity access control systems.InstallationRemove the cover by holding the unit as shown and pulling the cover from the top as illustratedIf necessary, drill holes for the mounting screws in the wall or mounting box on which the reader unit will be placed. (Use the Drilling Template provided).1. Place the controller and power supply cable through the Grommit hole.2. Drill the holes as indicated by the arrows. Note:  Make sure that you don't drill through the cable.Check your circuit diagram for the colour coding of the circuit wiring. The reader can be damaged beyond repair if the wiring is connected incorrectly. If the reader has the same power supply as the door latch relay, make sure that the relay is protected by a fast Schottky diode. If the relay is not protected reader operation will be affected.NOTE:   Power to the unit is provided from the Listed control unit or from a separately supplied UL Listed 12 Vdc power-limited, access control power source.Wiring methods shall be in accordance with the National Electrical Code, ANSI/NFPA 70.1.   Connect the 0V wire to the Power 0V line. NOTE:   The 0V line of all power supplies MUST be connected to a common 0V reference point. 2.   Connect the Wiegand signal cables. 3.   Connect the Buzzer and the LED cables. 4.   Attach the 12Vdc wire last. 5.   Place the reader on the wall (Make sure the wires are not crushed) 6.   Insert and hand tighten the screws.  7.   Check that the reader is level before tightening the screws.NOTE:   Excessive tightening of screws may deform the casing, resulting in a damaged unit.     This will void the warranty. 8.   Replace the cover. 9.   Power up the reader.NOTE:     The unit needs up to 15 seconds to set up before it can respond to a valid smart card.External Use  Mount the reader on a suitable external single gang surface mount box.  USA ONLY - BQT mounting plate adaptor is available for mounting to a US single gang box.  Make sure that the wire bundle to the 9 Series reader has an IP rating of at least IP67.  Use warming pads if the temperature of the reader is expected to fall below -10ºC (14ºF).Handling  Handle the 9 Series reader with care. Do not damage/drop unit before installation.   The reader unit will not be waterproof if the casing is damaged. Replace the reader if the casing is damaged.Maintenance  Once installed the 9 Series reader requires no maintenance. Troubleshooting  If the reader doesn't respond when a valid smart card is presented, check the following.If the problem still persists then please contact your distributor for technical support and to obtain an RMA if required. WarrantyThe 9 Series reader comes with a 5 year warranty from the date of dispatch from BQT Solutions. The warranty is void if the instructions contained within this manual have not been adhered to. NOTE: If reader beeps when a valid smart card is presented then the reader is functioning.Possible CauseNo power to the readerVoltage to the reader is below 10V   Invalid card or card is faultyWiring to the controller may be faulty.Check Check the power supply to the reader.Check the power supply to the readerCheck reader with another valid smart cardCheck the wiring to the controllerSymptomLED is not litLED is Orange or Buzzer sounds lowReader doesn't respondReader beeps but lock doesn't open45mm 62mm ➣➣➣➣20mm Ø4mm Ø4mm ØCMYCMMYCYCMYK9 series_v2.8.ai   15/08/2006   11:08:35 AM9 series_v2.8.ai   15/08/2006   11:08:35 AM

Navigation menu