Axesstel MV441 CDMA 1xEV-DO Rev.A WiFi Gateway, Dual-Band 800/1900MHz User Manual MV441

Axesstel Inc CDMA 1xEV-DO Rev.A WiFi Gateway, Dual-Band 800/1900MHz MV441

User Manual

   1
  2 Important Notice Due to the nature of wireless communications, transmission and reception of data can never be guaranteed. Data may be delayed, corrupted (i.e., have errors) or be totally lost. Although significant delays or losses of data are rare when wireless devices such as the Axesstel modem are used in a normal manner with a well-constructed network, the Axesstel modem should not be used in situations where failure to transmit or receive data could result in damage of any kind to the user or any other party, including but not limited to personal injury, death, or loss of property. Axesstel accepts no responsibility for damages of any kind resulting from delays or errors in data transmitted or received using the Axesstel modem, or for failure of the Axesstel modem to transmit or receive such data. Safety and Hazards Do not operate the Axesstel modem:   In areas where blasting is in progress   Where explosive atmospheres may be present   Near medical equipment   Near life support equipment, or any equipment that may be susceptible to any form of radio interference. In such areas, the Axesstel modem MUST BE POWERED OFF. The Axesstel modem can transmit signals that could interfere with this equipment. Do not operate the Axesstel modem in any aircraft, whether the aircraft is on the ground or in flight. In aircraft, the Axesstel modem MUST BE POWERED OFF. When operating, the Axesstel modem can transmit signals that could interfere with various onboard systems. Note: Some airlines may permit the use of cellular phones while the aircraft is on the ground and the door is open. The Axesstel modem may be used at this time. The driver or operator of any vehicle should not operate the Axesstel modem while in control of a vehicle. Doing so will detract from the driver or operator’s control and operation of that vehicle. In some states and provinces, operating such communications devices while in control of a vehicle is an offence.
   3 Limitation of Liability The information in this manual is subject to change without notice and does not represent a commitment on the part of Axesstel. AXESSTEL SPECIFICALLY DISCLAIMS LIABILITY FOR ANY AND ALL DIRECT, INDIRECT, SPECIAL, GENERAL, INCIDENTAL, CONSEQUENTIAL, PUNITIVE OR EXEMPLARY DAMAGES INCLUDING, BUT NOT LIMITED TO, LOSS OF PROFITS OR REVENUE OR ANTICIPATED PROFITS OR REVENUE ARISING OUT OF THE USE OR INABILITY TO USE ANY AXESSTEL PRODUCT, EVEN IF AXESSTEL HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR THEY ARE FORESEEABLE OR FOR CLAIMS BY ANY THIRD PARTY. Notwithstanding the foregoing, in no event shall Axesstel aggregate liability arising under or in connection with the Axesstel product, regardless of the number of events, occurrences, or claims giving rise to liability, be in excess of the price paid by the purchaser for the Axesstel product.
  4 Table of Contents  1. Introduction ……………………………………….…...………….   5 2. Product Overview …………………………….………...…...…..   7 3. Knowing your Modem ……………………….……..…………...   10 Package Contents …………………………………………………   10 Modem Interfaces ………………………………………….………   10 System Components ………………………………………………   13 4. Connecting and Configuring your Modem ………………….   15 5. Web Manager User Interface …………….………………….....   18 Basic Settings ………………………….……….………………….   22 Configuring the Wireless Network Settings ………..…………...  23 Router Status ……………………………………….…….………..   27 Password……………………………………………………………. 28 Firmware Information………………………………………………. 29 Configuring Port Forwarding ……………………….……………..  30 IP Filter………………………………………………………………. 31 MAC Filter…………………………………………………………… 32 Firewall/DMZ Services……………………………………………... 33 Static Routing……………………………………………………….. 34 LAN Setting….………………………………………………………. 35 Dynamic DNS …………………………………………….….……..  36 6. Troubleshooting ………………………………………………….   37 7. Technical Specification …………………………………………   40 8. Glossary ……………………………………………………….......   41      Version:V3.4C(110402)
   5 Introduction  Thank you for purchasing the Axesstel MV441EV-DO Modem (the Modem). This user manual will help you setup, configure and outline best practices for maximizing your wireless home network performance with the Modem. Please be sure to read through this User Manual completely, and pay special attention to the section entitled “Placement of your Modem for Optimal Performance” on page 2.  Placement of your Modem for Optimal Performance  Your wireless connection will be stronger the closer your computer is to your Modem. Typical indoor operating range for Wi-Fi wireless devices is between 100 and 200 feet. For EV-DO operation, a line-of-sight with the radio base station is preferred and yields the strongest signal strength.  In the same way, your wireless connection and performance will degrade somewhat as the distance between your Modem and connected devices increases, as well as between the Modem and the radio base station. This may or may not be noticeable to you. As you move farther from your Modem, connection speed may decrease. Factors that can weaken signals simply by getting in the way of your network’s radio waves are metal appliances or obstructions, and walls.  Note: While some of the items listed below can affect network performance, they will not prohibit your wireless network from functioning; if you are concerned that your network is not operating at its maximum effectiveness, this checklist may help.  1. Modem Placement Place your Modem, the central connection point of your network, as close as possible to windows or in rooms at the outer side of your house. If you also use the Wi-Fi feature of the Modem, it should be placed near the center of your wireless network devices. To achieve the best wireless network coverage: •  Ensure that your Modem’s networking antennas are parallel to each other, and are positioned vertically (toward the ceiling). If your Modem itself is positioned vertically, point the antennas as much as possible in an upward direction.
  6 •  In multistory homes, place the Modem on an upper floor. •  Try not to place the Modem near a cordless phone (MV400-series only).  2. Avoid Obstacles and Interference Avoid placing your Modem near devices that may emit radio “noise,” such as microwave ovens. Dense objects that can inhibit wireless communication include: • Refrigerators •  Washers and/or dryers • Metal cabinets • Large aquariums •  Metallic-based, UV-tinted windows If your wireless signal seems weak in some spots, try to move the Modem to another location while observing the signal strength indicator. Since you may not know the location of an EV-DO radio base station serving your Modem, try to call your service provider and ask for the nearest base station of your home. Try placing the Modem closest and unobstructed to that base station.
   7 Product Overview In minutes you will be able to connect your computers to the Internet, share your Internet connection and network your computers. The following is a list of features that make your new Axesstel EV-DO Modem an ideal solution for your home or small office network. Implementation of these features depends on the particular service provider and account features you have chosen. Some features described in this manual may not be supported by your service provider or may not be available with your network account. For details of the services and accounts available, contact your service provider. CDMA 3G services The Modem operates over the CDMA 3G technology that provides a variety of connectivity features, depending on your service provider and account:   1xEVDO Rev. A supports Internet connections with data rates up to 3.1 Mbps (downlink from the network) and 1.8 Mbps (uplink to the network). Average data rates are roughly 600–1300 Kbps (downlink from the network) and 300–400 Kbps (uplink to the network). Actual speed depends on the network conditions.   1xEVDO Rev. 0 supports Internet connections with data rates up to 2.4 Mbps (downlink from the network) and 153 Kbps (uplink to the network). Average data rates are roughly 400–700 Kbps (downlink from the network) and 40–80 Kbps (uplink to the network). Actual speed depends on the network conditions.   1X supports Internet connections with data rates up to 153 Kbps. Actual speed depends on the network conditions. Once the connection is established, you can open your browser and connect to any web site that is accessible through the Internet, or access other Internet services (such as email). The connection is “active” when data transmission is occurring. If data transmission stops for a period of time (determined by the network), the connection becomes “dormant”; see page 26.
  8 Plug-and-Play Each Modem has been provisioned at the factory for use with a particular service provider. This sets the Modem to use particular radio channels and enables services specific for that provider. Although the Modem comes with drivers and enabling software, you don’t have to install and use them if you simply want to connect to the Internet, assuming that your Modem has been activated with the network (The process of setting up your account is called activation. Activation involves action by the service provider and configuration of the Modem.) Once the Modem has been activated, simply connect your computer with the Modem using the provided Ethernet (RJ-45) cable and you are ready to use the Internet.   Works with Both PCs and Mac® Computers The Modem supports a variety of networking environments including Mac OS® 9.x, X v10.x, AppleTalk®, Linux®, Windows® 98, Me, NT®, 2000, and XP, and others. All that is needed is an Internet browser and a network adapter that supports TCP/IP (the standard language of the Internet).  Top-View LED Display Lighted LEDs on the top of the Modem indicate which functions are in operation. You’ll know at-a-glance whether your Modem is in EV-DO or 1X mode, connected to the Internet, and in Wi-Fi or Ethernet operation. This feature eliminates the need for advanced software and status-monitoring procedures.  Web-Based Advanced User Interface You can set up the Modem’s advanced functions easily through web browser, without having to install additional software onto the computer. There are no disks to install or keep track of and, best of all, you can make changes and perform setup functions from any computer on the network quickly and easily.  NAT IP Address Sharing Your Modem employs Network Address Translation (NAT) to share the single IP address assigned to you by your Internet Service Provider while saving the cost of adding IP addresses to your Internet service account.  Integrated 10/100 4-Port Switch The Modem has a built-in, 4-port network switch to allow your wired computers to share printers, data and MP3 files, digital photos, and much more. The switch features automatic detection so it will adjust to the speed of connected devices.
   9 The switch will transfer data between computers and the Internet simultaneously without interrupting or consuming resources.  Built-In Dynamic Host Configuration Protocol (DHCP) Built-In Dynamic Host Configuration Protocol (DHCP) on-board makes for the easiest possible connection of a network. The DHCP server will assign IP addresses to each computer automatically so there is no need for a complicated networking setup.  Integrated 802.11n Wireless Access Point 802.11n is an exciting new wireless technology that achieves data rates up to 600Mbps, nearly twelve times faster than 802.11g.  MAC Address Filtering For added security, you can set up a list of MAC addresses (unique client identifiers) that are allowed access to your network. Every computer has its own MAC address. Simply enter these MAC addresses into a list using the Web-Based Advanced User Interface and you can control access to your network.
  10 Knowing your Modem  Package Contents • EV-DO Modem • User Manual •  RJ45 Ethernet Networking Cable •  Power Supply and Battery(Option) •  1xEVDO 450M(MV411) or 800M/1900(MV441) antenna  Modem Interfaces The Modem has been designed to be placed on a desktop or wall mounted. All of the cables exit from the front of the Modem for better organization and utility. The LED indicators are easily visible on the top of the Modem to provide you with information about network activity and status.        1. Power LED  OFF  Modem is OFF Solid Green  Battery connected & fully charged Solid Orange  Battery connected & half charged Solid Red  Battery connected & low Blinking Red  Battery connected & charging error Blinking Green with Charger  Charging Solid Green withCharger   Fully charged  2. Signal Strength LED
   11 This LED indicates the signal strength of the CDMA network serving your Modem.   OFF  No EV-DO or 1X signal Solid Green  Strongest level Solid Orange  Medium level Solid Red  Low signal Blinking Red  UIM card need input PIN number 3. Connect LED This LED informs you that the Modem is connected to a wireless network and passed through the user/password validation.    OFF  Modem is not connected to network Solid Green  Modem is connected to network Blinking Green  Modem is dialing to network  4. 1x/EV-DO LED This LED informs you that the Modem is tuned to a 1x or EV-DO wireless network. Normally your Modem is programmed to search and use EV-DO network. If unavailable, the Modem will try to search for a 1x network. Please check with your Service Provider for default setting.  OFF 1x Solid Green  EV-DO  5. Ethernet LED This LED indicates that there are computers connecting to your Modem via one of the RJ-45 ports. When the LED is blinking, it indicates that there are activities (data passed through).    OFF  No RJ-45 (Ethernet) connection Solid Green  At least one of the RJ-45 ports in use 6. Wi-Fi LED (MV441) This LED indicates that your Modem is setup to have Wi-Fi capability. When the LED is blinking, it indicates that there are activities (data passed through).
  12 OFF No Wi-Fi Solid Green  Wi-Fi network within Modem is activated Blinking Green  Active data passed through Wi-Fi          7. USB Connection to Computers Connect your wired (non-wireless) computer to this port using the supplied USB cable.  8. USB/RJ-45 Switch This switch allows your Modem to connect with your computer via either USB port or RJ-45 ports. USB port is just for debug, if you want to access to internet, the switch must be at RJ-45 port side.    9. Connections to Computers (Wired Computer Ports) Connect your wired (non-wireless) computers to these ports. These ports are RJ45, 10/100 auto-negotiation, auto up-linking ports for standard UTP category 5 or 6 Ethernet cable. The ports are labeled 1 through 4.  10. Power Jack Connect the included 12V DC power supply to this jack.  11. Rechargeable Battery (Optional)
   13 System components Your Modem is just one part of a system designed to provide you with a wide range of communication features. Every component of the system is needed to enable these capabilities. Your host computing device Your notebook or PC hosts the Modem and runs the communication software: your web browser or email application and Connection Manager—the Modem enabling software. You may also have other software on your computer that can be used wirelessly with the Modem, such as: file transfer applications (FTP), chat or instant messaging, a VPN (Virtual Private Network) client, client software for a corporate server application. The Modem The Modem provides your computer with a connection to the CDMA wireless network. Every CDMA network operates on one of three radio frequency bands (450MHz, 800MHz and 1900MHz). The Modem is available in two configurations: MV411 single-band 450MHz Modem, MV441 dual-band 800/1900MHz Modem.   A CDMA service provider account Companies that operate CDMA networks and provide access to these networks are called service providers. To use the Modem, you must have an account with a CDMA service provider. Each service provider has its own pricing options. There may be flat rate accounts, which provide you a maximum number of minutes of network usage for a fixed monthly fee. There may be accounts for which you are charged for network usage by the minute or by the amount of data transmitted. Your account may include a variety of other services such as SMS messaging. Each Modem has been provisioned at the factory for use with a particular service provider. This sets the Modem to use particular radio channels and enables services specific for that provider. The process of setting up your account is called activation. Activation involves action by the service provider and configuration of the Modem.
  14 The CDMA wireless network This is the worldwide infrastructure providing the radio coverage that allows you to stay connected. Made up of radio towers and a variety of network switches, routers, and servers, the network is an interconnection of many service providers.   Note: More information about CDMA networks is available on the CDMA Development Group web site, www.cdg.org. There are CDMA networks that operate in the frequency bands supported by the Modem throughout North America and parts of Latin America, Asia, and New Zealand. However, each service provider operates a network that covers a limited geographical area within the overall CDMA coverage area. Note: Some service providers have coverage maps on their web sites.
   15 Connecting and Configuring your Modem  Each Modem has been provisioned at the factory for use with a particular service provider. This sets the Modem to use particular radio channels and enables services specific for that provider.   MV441 and MV441i: All drivers and software have been installed into your modem, you don’t have to install  anything  if you simply want to connect to the Internet through the Ethernet (RJ-45) ports, assuming that your Modem has been activated with the network. Simply connect your computer with the Modem using the provided Ethernet (RJ-45) cable and you are ready to use the Internet. Step 1 │ Set up the Hardware 1.1.  Make sure your Modem is not connected to any power source and all the LED are OFF. 1.2  Locate the CAT-5 Ethernet cable that is included with your Modem. Plug one end of this cable into ANY one of the Ethernet ports on your Modem. Plug the other end of the cable into the networking port on your computer. 1.3  Locate the power supply that is included with your Modem. Plug the power supply’s small connector into the power port on the Modem. Plug the power supply into an empty power outlet. 1.4  Switch on the Modem. Look at the Power LED on top of the Modem and make sure the lights are ON. 1.5  Wait for a few seconds for the Modem to search for service network. Once the Modem finds a suitable network, observe the Signal LED turns to Red, Orange or Green depending on the strength of acquired signal. Refer to the Signal Strength LED description for more details. Step 2 │ Preparing your PC The Modem’s Ethernet is configured with DHCP by default. This means that IP address of your PC is automatically assigned by the Modem. Make sure that your PC has the correct TCP/IP setting for its "Local Area Connection" by following the steps below.
  16 2.1 Click "Start", select "Connect To" and scroll down to "Show all connections" and left click it.  2.2 Right click "Local Area    Connection" scroll down to     "Properties" and left click it          2.3 Select the “Internet Protocol (TCP/IP)”. Press the “Properties” button. If there is no TCP/IP line listed, you will need to install TCP/IP first.
   17  2.4 Check “Obtain an IP address automatically” 2.5 Check “Obtain DNS Server address automatically”   2.6 Click Ok to exit Properties 2.7 If asked to re-start the PC, click “YES”.
  18 Web Manager User Interface     The Web Manager User Interface is a web-based tool that you can use to set up the Modem if you don’t want to use the default setting of Web page. You can also use it to manage advanced functions of the Modem. From the User Interface, you can perform the following tasks: •  View the Modem’s current settings and status •  Configure the EVDO network mode, amend the Dialer number, PPP username, PPP password and authentication mode •  Configure the wireless settings such as SSID, security mode, enable or disable wireless network, hide wireless network to satisfy different requirement(not applicable to MV400i-series) •  Configure the Modem's router function to connect to your Service Provider with the settings that they provided you •  Change the current network settings such as the Internal IP address, the IP address pool, DHCP settings, and more •  Set the Modem’s port forwarding   •  Enable or disable the Modem’s firewall, enable DMZ function to let you set a single computer on your network outside of the router •  Set up security features such as client restrictions, MAC address filtering •  Enable the Firewall and DMZ feature for a single computer on your network •  Change the Modem’s internal password •  Configure Dynamic DNS function •  View the Modem’s current 3G information, connected DHCP clients and WLAN clients. •  Reset the Modem’s default settings •  Update the Modem’s firmware Step 1 │ Access Network Setup Follow below steps to configure your Modem’s Ethernet connection.
   19 1. Connect the PC to your Modem using the CAT-5 Ethernet cable. Use ANY one of the Ethernet ports on your Modem. 2. Power on the device, waiting for about 90 seconds until the device finish   initializing. 3. Open your Web browser and enter 192.168.0.1 in the address bar          2. A new  webpage will appear. When prompt for User name and password, enter the following user id and password.          User Name: admin          Password:  admin * If you have changed the user name and the password, enter the new user name
  20 and password. Note: This user name and password are only for the Web Manager access. Changing these settings does not change Dial Connection user profile name and password. After entering the correct user name and password then click Login button, the web browser will change to “Basic Setting” page. See the following picture: Note: If the Modem is UIM card mode and UIM card need PIN number, when you first enter this page, the page will be different, it is shown as the following picture in the next page, at the same time the signal LED will be red blinking to tell you need input the PIN number. For detailed information, please refer next chapter.
   21  Step 2 │Navigate web-based UI 2.1  The Basic Setting page is the first page you will see when you access the web based Advanced User Interface (UI). The basic setting page shows you a quick view of the Modem’s login setting. All advanced setup pages can be reached from this page.
  22               1. Quick Navigation Links You can go directly to any of the Modem’s UI pages by clicking directly on these links. The links are divided into logical categories and grouped by tabs to make finding a particular setting easier to find.   2. Page Contents This part show the detailed information of the Navigation Link, This User Manual will sometimes refer to pages by name. For instance “Advanced > LAN IP Setup” refers to the “LAN IP Setup” page.   Basic Settings Clicking on the header of the “Basic Settings” tab will take you to the “Basic Settings” header page. From this page, the Modem’s basic settings can be modified. These settings include:   WAN Connection: A drop down menu allows users to change the providers. The default value is Hybrid  Mode(EV-DO+1X)    Dial No [1] [2]
   23   PPP Login ID and password (if applicable)   Authentication Method:  A drop down menu allows users to change the authentication method. The default value is AUTO   Connection mode: User can choose one connection mode from “always”; “manual” & “on demand”: “always”: Modem will always connect to CDMA network when it is power on, “manual”: User can use “connect”; “disconnect” button to control whether modem connect to CDMA network or not,   “on demand”: Modem will connect to CDMA network when there are network requirement, and will disconnect when there are no network requirement in a period of time(Maximum idle time), The default selection is “always”.       Configuring the Wireless Network Settings Clicking on the header of the “Wireless Settings” tab will take you to the “Wireless Settings” header page. From this page, the Modem’s Wi-Fi router
  24 wireless radio can be enabled or disabled (the default setting is enabled). There are options that allow you to make changes to the Wi-Fi wireless network settings. Changing the Wireless Network Name (SSID) To identify your wireless network, a name called the SSID (Service Set Identifier) is used. The default SSID of the Modem is “AxessMV441”. You can change this to anything you want to or you can leave it unchanged. If there are other wireless networks operating in your area, you will want to make sure that your SSID is unique (does not match that of another wireless network in the area). To change the SSID, type in the SSID that you want to use in the “SSID” field and click “Apply”. The change is immediate. If you make a change to the SSID, your wireless-equipped computers may also need to be reconfigured to connect to your new network name. Refer to the documentation of your wireless network adapter for information on making this change. Changing the Wireless Channel There are a number of operating channels you can choose from. In the United States and Australia, there are 11 channels. In the United Kingdom and most of Europe, there are 13 channels. In a small number of other countries, there are
   25 other channel requirements. Your Modem is configured to operate on the proper channels for the country you reside in. If you don’t know which channel does your country use, you can select “Enable  Auto  Channel  Scan”, let the router help you automatically select channel, this function is default to be active. The channel can be changed if needed. If there are other wireless networks operating in your area, your network should be set to operate on a channel that is different than the other wireless networks. For best performance, use a channel that is at least five channels away from the other wireless network. For instance, if another network is operating on channel 11, then set your network to channel 6 or below. To change the channel, select the channel from the drop-down list. Click “Apply”. The change is immediate. Using the Wireless Mode Switch Your Modem can operate in three different wireless modes: “b and g”, “n only”, and “b,g and n”.   b,g and n Mode In this mode, the Modem is compatible with 802.11b,g and n wireless clients simultaneously. This is the factory default mode and ensures successful operation with all Wi-Fi compatible devices. If you have a mix of 802.11b,g and n clients in your network, we recommend setting the Modem to 802.11b,g and n mode. This setting should only be changed if you have a specific reason to do so. b and g Mode b and g mode works with 802.11b,g clients only, not 802.11n clients. This mode is recommended only if your clients do not support 802.11n mode.To switch modes, select the desired mode from the “Wireless Mode” drop-down box. Then, click “Apply Changes”. n only Mode n only mode works with 802.11n clients only. This mode is recommended only if you want to prevent 802.11b and g clients from accessing your network. When to use b and g Mode In some cases, older 802.11b,g clients may not be compatible with 802.11n wireless. These adapters tend to be of inferior design and may use older drivers
  26 or technology. Switching to this mode can solve problems that sometimes occur with these clients. If you suspect that you are using a client adapter that falls into this category of adapters, first check with the adapter vendor to see if there is a driver update. If there is no driver update available, switching to b and g mode may fix your problem. Please note that switching to n only mode will decrease 802.11b and g performance. Securing your Wi-Fi® Network Here are a few different ways you can maximize the security of your wireless network and protect your data from prying eyes and ears. This section is intended for the home, home office, and small office user. At the time of this User Manual’s publication, there are three encryption methods available. WEP (Wired Equivalent Privacy) WEP (Wired Equivalent Privacy) is a common protocol that adds security to all Wi-Fi compliant wireless products. WEP was designed to give wireless networks the equivalent level of privacy protection as a comparable wired network. WPA (Wi-Fi Protected Access) WPA (Wi-Fi Protected Access) is a new Wi-Fi standard that was designed to improve upon the security features of WEP. To use WPA security, the drivers and software of your wireless equipment must be upgraded to support WPA. These updates will be found on the wireless vendor’s website.   WPA-PSK (no server) uses what is known as a pre-shared key as the network key. A network key is basically a password that is between eight and 63 characters long. It can be a combination of letters, numbers, or characters. Each client uses the same network key to access the network. Typically, this is the mode that will be used in a home environment. WPA2 (Wi-Fi Protected Access 2) Short for Wi-Fi Protected Access 2, the follow on security method to WPA for wireless networks that provides stronger data protection and network access control. It provides enterprise and consumer Wi-Fi users with a high level of assurance that only authorized users can access their wireless networks. Based on the IEEE 802.11i standard, WPA2 provides government grade
   27 security by implementing the National Institute of Standards and Technology (NIST) FIPS 140-2 compliant AES encryption algorithm and 802.1x-based authentication. Maintenance: Router Status Clicking on the header of the “Router Status” tab will take you to the “Router Status” header page. A quick description of the functions can be found here. 1. IP Address The “IP address” is the internal IP address of the Modem. The default IP address is “192.168.0.1”. To access the web based Advanced User Interface, type this IP address into the address bar of your browser. This address can be changed if needed. 2. Subnet Mask This is a unique, advanced feature of your Axesstel Modem. It is possible to change the subnet mask if necessary; however, do NOT make changes to the subnet mask unless you have a specific reason to do so. The default setting is “255.255.255.0”.
  28 From this page, users can see all settings associated with the Modem’s router network functions. These functions include:   Current Firmware Version and Date   WAN Port: IP Address, Remote IP Address, DNS Primary Address and DNS Secondary Address   LAN Port: MAC Address, IP Address, IP Subnet Mask and  DHCP status   Wi-Fi Port : MAC  Address,  SSID, Channel, Mode, Wireless AP status (ON/OFF); Broadcast SSID status (ON/OFF) & Security Mode status Password Click on the header of the “Password” tab will take you to the “Set Password” header page. This function will allow you to change the access password for enter the web-GUI page.
   29 Firmware Information Click on the header of the “Firmware Information” tab will take you to the “Firmware Information” header page. In this page you can view the current firmware version and release date. Also you can update the firmware of the modem by click “Update Firmware” button. Click “Restore button” can help you restore all configuration to factory value.
  30 Configuring Port Forwarding Clicking on the header of the “Port Forwarding” tab will take you to the “Port Forwarding” header page. This function will allow you to route external (Internet) calls for services such as a web server (port 80), FTP server (Port 21), or other applications through your Router to your internal network. Since your internal computers are protected by a firewall, computers outside your network (over the Internet) cannot get to them because they cannot be “seen.” A list of common applications has been provided in case you need to configure the “Port Forwarding” function for a specific application. You will need to contact the application vendor to find out which port settings you need. Note: This advanced feature should be employed by advanced users only. Enable/Disable Port Forwarding To enable port forwarding, first you need to active “Firewall” function in “Firewall/DMZ Services” page, then just add setting in “Add Port Forwarding Rules” and click “apply”. To disable port forwarding, you can simply uncheck “Firewall” function in “Firewall/DMZ Services” or remove all the rules you have set. Entering Settings into the Port Forwarding To enter settings, you need to input the Service Name (For Example: FTP) and  External  Port,  then  select the service from the dropdown box “Protocol”. You will see a list of common applications (TCP/UDP). Select the desired applications, enter the IP address and the port number in the space provided for the internal (server) machine and click “Apply”. Opening ports in your firewall
   31 can pose a security risk. It is recommended that you disable the settings when you are not using a specific application. IP Filter The Modem can be configured to restrict access to the Internet, email, or other network services at specific days and times. Restriction can be set for a single computer, a range of computers, or multiple computers. To restrict Internet access to a single computer, for example, enter the Start/End  IP address of the computer you wish to restrict access to in the IP fields. Next, choose “Protocol” as “TCP/UDP”, enter “80” in both the port fields. Click “Apply”.  Note: To enable this function, you should active “Firewall” function in “Firewall/DMZ Services”.
  32 MAC Filter The MAC address filter is a powerful security feature that allows you to specify which computers are allowed on the network. Any computer attempting to access the network that is not specified in the filter list will be denied access. When you enable this feature, you must enter the MAC address of each client (computer) on your network to allow network access to each. To use MAC Filter function, you should check “ON/OFF” box at first. When MAC Filter Services is enabled, it can be set in 2 modes.   Black List. In this mode, the service table shows the client MAC address being blocked by the Modem.   White List. In this mode, the service table shows the client MAC address allowed by the Modem. To add a MAC address into the service table, simply enter the MAC address and click “Add”. Note: You will not be able to delete the MAC address of the computer you are using to access the Router’s administrative functions (the computer you are using now).
   33 Firewall/DMZ Services Clicking on the header of the “Firewall/DMZ  Services” tab will take you to the “Firewall/DMZ  Services” header page. From this page, the Modem’s Firewall  & DMZ can be enabled or disabled. WAN Ping Blocking Computer hackers use what is known as “pinging” to find potential victims on the Internet. By pinging a specific IP address and receiving a response from the IP address, a hacker can determine that something of interest might be there. The Modem can be set up so it will not respond to a  ping request  from  WAN. This heightens the level of security of your Modem. To turn OFF the ping response, enable firewall at first, then uncheck “Respond to ping on internet port” and click “Apply”. The Modem will not respond to any ping from WAN. HTTP Request Blocking Computer hackers will also use HTTP request to attack your modem sometime, also you can block the HTTP request from WAN by setting on modem. To turn OFF the HTTP response, enable firewall at first,  then uncheck “Respond to HTTP on Internet Port” and click “Apply”. The Modem will not respond to any HTTP ping.
  34 Enabling the Demilitarized Zone (DMZ) The DMZ feature allows you to specify one computer on your network to be placed outside of the firewall. This may be necessary if the firewall is causing problems with an application such as a game or video conferencing application. Use this feature on a temporary basis. The computer in the DMZ is NOT protected from hacker attacks. Static Routing A static IP address connection type is less common than other connection types. If your ISP uses static IP addressing, you will need your IP address, subnet mask, and ISP gateway address. This information is available from your ISP or on the paperwork that your ISP left with you. Type in your information, and click “Apply”. 1. DST  IPAddress: Provided by your ISP. Enter your IP address here. 2. Net Mask: Provided by your ISP. Enter your subnet mask here. 3. Gateway Address: Provided by your ISP. Enter the ISP gateway address here. 4. Interface: Provided by your ISP. Enter the  Interface here.
   35 LAN Setting Clicking on the header of the “LAN Setting” tab will take you to its header page.   Router Setting All settings for the internal LAN setup of the Router can be viewed and changed here. 1. Router IP Address: The “Router IP address” is the internal IP address of the Modem. The default IP address is “192.168.0.1”. To access the Web Manager User Interface, type this IP address into the address bar of your browser. This address can be changed if needed. To change the IP address, type in the new IP address and click “Apply”. The IP address you choose should be a non-routable IP. Examples of a non-routable IP are:
  36 192.168.x.x (where x is anything between 0 and 255), and 10.x.x.x (where x is anything between 0 and 255). 2. Subnet Mask: There is no need to change the subnet mask. This is a unique, advanced feature of your Modem. It is possible to change the subnet mask if necessary; however, do NOT make changes to the subnet mask unless you have a specific reason to do so. The default setting is “255.255.255.0”. Enable DHCP Server The DHCP server function makes setting up a network very easy by assigning IP addresses to each computer on the network automatically. The DHCP server can be turned OFF if necessary; however, in order to do so you must manually set a static IP address for each computer on your network. To turn off the DHCP  server, de-select “Enable  DHCP Server” and click “Apply”. Dynamic DNS Clicking on the header of the “Dynamic  DNS” tab will take you to its header page.  To use DDNS function, just select “Enable DDNS” then input the username/password you got from your service provide and click “apply”. 3G Information
   37 Troubleshooting Problem: •  The Install software completed installation, but my web browser doesn’t work.   •  I am unable to connect to the Internet. The Modem’s “Signal” light is on and the “Connect” light is off. Solution: If you cannot connect to the Internet, the “Signal” light is on, and the “Connect” light is off, the problem may be your connection type may not match the ISP’s connection. •  If you have a “static IP address” connection, your ISP must assign you the IP address, subnet mask, and gateway address. Please refer to the section entitled “Alternate Setup Method” for details on changing this setting. •  If you are still unable to access the Internet after verifying these settings, please contact your Service Provider Technical Support. Problem: •  The Install software completed installation, but my web browser doesn’t work.   •  I am unable to connect to the Internet. The Modem’s “Signal” light is on and the “Connect” light is on. Solution: If the “Signal” light is on, and the “Connect” light is on, but you are unable to access the Internet, there may be third-party firewall software installed on the computer attempting to access the Internet. Examples of third-party firewall software are ZoneAlarm, BlackICE PC Protection, McAfee Personal Firewall, and Norton Personal Firewall. If you do have firewall software installed on your computer, please make sure that you properly configure it. You can determine if the firewall software is preventing Internet access by temporarily turning it off. If, while the firewall is disabled and Internet access works properly, you will need to
  38 change the firewall settings to function properly when it is turned on. Please refer to the instructions provided by the publisher of your firewall software for instructions on configuring the firewall to allow Internet access. If you are still unable to access the Internet after disabling any firewall software, please contact your Service Provider Technical Support.  Problem: I can’t connect to the Internet wirelessly from my computer but it works if I use the Ethernet cable. Solution: If you are unable to connect to the Internet from a wireless computer, please do the following: 1. Look at the lights on your Modem. Your Modem’s lights should be as follows: •  The “Power” light should be on. •  The “Connected” light should be on and not blinking. •  The “WAN” light should be either on or blinking. 2. Open your wireless utility software by clicking on the icon in the system tray at the bottom, right-hand corner of the screen. 3. The exact window that opens will vary depending on the model of wireless card you have; however, any of the utilities should have a list of “Available Networks”—those wireless networks it can connect to. Problem: My wireless network performance is inconsistent. Data transfer is sometimes slow. Signal strength is poor. I am having difficulty establishing and/or maintaining a Virtual Private Network (VPN) connection. Solution: Wireless technology is radio-based, which means connectivity and the throughput performance between devices decreases when the distance
   39 between devices increases. Other factors that will cause signal degradation (metal is generally the worst culprit) are obstructions such as walls and metal appliances. As a result, the typical indoor range of your wireless devices will be between 100 to 200 feet. Note also that connection speed may decrease as you move farther away from the Modem or access point.   In order to determine if wireless issues are related to range, we suggest temporarily moving the computer, if possible, five to 10 feet away from the Modem.  Changing the Wireless Channel - Depending on local wireless traffic and interference, switching the wireless channel of your network can improve performance and reliability. The default channel the Modem is shipped with is channel 11. You may choose from several other channels depending on your region (see the section titled “Changing the Wireless Channel” on page 41 for instructions on how to choose other channels).   Limiting the Wireless Transmit Rate - Limiting the wireless transmit rate can help improve the maximum wireless range and connection stability. Most wireless cards have the ability to limit the transmission rate. To change this property, go to the Windows Control Panel, open “Network Connections” and double-click on your wireless card’s connection. In the “Properties” dialog, select the “Configure” button on the “General” tab (Windows 98 users will have to select the wireless card in the list box and then click “Properties”), then choose the “Advanced” tab and select the rate property. Wireless client cards are usually set to automatically adjust the wireless transmit rate for you, but doing so can cause periodic disconnects when the wireless signal is too weak; as a rule, slower transmission rates are more stable. Experiment with different connection rates until you find the best one for your environment; note that all available transmission rates should be acceptable for browsing the Internet. For more assistance, see your wireless card’s user manual.
  40 Technical Specifications This chapter provides technical product data for the Modem. Radio frequency and electrical specifications  Frequency Range  MV411  Rx: 463 ~ 468 MHz Tx: 453 ~ 458 MHz Frequency Range  MV441  Rx: 859.64 ~ 893.37 MHz Tx: 824.64 ~ 848.37 MHz Frequency Range MV441  Rx: 1930 ~ 1989.95 MHz Tx: 1850 ~ 1909.95 MHz Channel Bandwidth  CDMA 1.23 MHz Stability of frequency  0.4 ppm External appearance (mm)  160 x 178 x 40 mm Weight  600 g (with battery) Sending output  maximum 0.23W E.R.P Temperature of operation Relative humidity -20 ~ +50 degrees Celsius   5% ~ 90% Adapter  Input: AC 100~240V 50~60Hz   Output: DC 12V/1A Battery Operation 2.5 Hrs                                                              AXT_GD_v1.0
   41 Appendix A: Glossary  1X   One Times Radio Transmission Technology (the “one times” refers to the frequency spectrum). Supports Internet connections with data rates up to 153 Kbps. Actual speed depends on the network conditions. Compare to 1x EV-DO. 1x-EVDO    A high speed standard for cellular packet data communications Rev. A supports Internet connections with data rates up to3.1 Mbps (downlink from the network) and 1.8 Mbps (uplink to the network). Rev. 0 supports Internet connections with data rates up to 2.4 Mbps (downlink from the network) and 153 Kbps (uplink to the network).  Average data rates are roughly: for Rev. A: 600–1300 Kbps (downlink from the network) and 300–400 Kbps (uplink to the network); for Rev. 0: 400–700 Kbps (downlink from the network) and 40 80 Kbps (uplink to the network). ‐ Actual speed depends on the network conditions. Compare to 1X. bps   bits per second—The actual data speed over the transmission medium.  CDMA   Code Division Multiple Access—A wideband spread spectrum technique used in digital cellular, personal communications services, and other wireless networks. Wide channels (1.25 MHz) are obtained through spread spectrum transmissions, thus allowing many active users to share the same channel. Each user is assigned a unique digital code, which differentiates the individual conversations on the same channel.   CDMA 1X   Also known as 1X, this is a high speed standard for CDMA cellular communications.   dormant    The packet data connection has the logical PPP session left open while the underlying physical link (the radio channel) is released. When traffic is to resume, a radio channel is reacquired and the original PPP session resumes.
  42 ESN  Electronic Serial Number—The unique first generation serial number assigned to the Modem for cellular network use. Compare to MEID.   FCC  Federal Communications Commission. The U.S. federal agency that is responsible for interstate and foreign communications. The FCC regulates commercial and private radio spectrum management, sets rates for communications services, determines standards for equipment, and controls broadcast licensing. Consult www.fcc.gov.   firmware   Software stored in ROM or EEPROM; essential programs that remain even when the system is turned off. Firmware is easier to change than hardware but more permanent than software stored on disk.   host    1. A computer that uses a modem or a similar device to answer a calling computer. 2. A source or destination in the communication network. 3. A computer that contains data or files to be accessed by client computers. Also known as a server. IS   Interim Standard—After receiving industry consensus, the TIA forwards the standard to ANSI for approval.   IS-95    The standard for CDMA Kbps   Kilobits per second—Actually 1000, not 1024, as used in computer memory size measurements of kilobytes. LAN   Local Area Network  LED    Light Emitting Diode—A semiconductor diode that emits visible or infrared light.   MEID   Mobile Equipment Identifier—The unique second-generation serial number assigned to the Modem for cellular network use. Compare to ESN.   MHz    Mega Hertz—One million cycles per second.   Mbps    Megabits per second   packet   A short fixed length block of data including a header that is ‐
   43 transmitted as a unit in a communications network.   PCS   Personal Communications Services—A cellular communication infrastructure that uses a different frequency range than AMPS.   roaming    A cellular subscriber is in an area where service is obtained from a cellular service provider that is not the subscriber’s provider.   RUIM    Removable User Identity Module. By having a removable identity card, CDMA users can change phones while keeping their phone numbers by simply swapping the cards.   SMS   Short message services—A feature that allows users of a wireless device on a wireless network to receive or transmit short electronic alphanumeric messages (up to 160 characters, depending on the service provider). system tray    Usually located in the lower right corner of your screen TIA   Telecommunications Industry Association—A standards-setting trade organization, whose members provide communications and information technology products, systems, distribution services and professional services in the United States and around the world. Consult www.tiaonline.org. VPN   Virtual Private Network FCC Regulations: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a  residential installation. This equipment generates, uses and can radiated radio frequency energy and, if not installed and used in accordance with the
  44   instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular  installation If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect  the  equipment  into  an  outlet  on  a  circuit  different  from  that  to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by the party responsible for compliance could void the user‘s authority to operate the equipment. 4RF Exposure Information This  device  meets  the  government’s  requirements  for  exposure  to  radio waves. This  device  is  designed  and  manufactured  not  to  exceed  the  emission limits  for  exposure  to  radio  frequency  (RF)  energy  set  by  the  Federal Communications Commission of the U.S. Government.  This device complies with FCC radiation exposure limits set forth for an uncontrolled environment. In order to avoid the possibility of exceeding the FCC radio frequency exposure limits, human proximity to the antenna shall not be less than 20cm (8 inches) during normal operation.
   45

Navigation menu