Axell Wireless 55-165703 55-165703 Cell Enhancer User Manual 80 330501HBKM

Axell Wireless 55-165703 Cell Enhancer 80 330501HBKM

manual 3 of 5

STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 250 of 500   14.3.5.  Attenuator 25W, 60dB (10-002960)   In many practical applications for Cell Enhancers etc., the gain in each path is found to be excessive. Therefore, provision is made within the unit for the setting of attenuation in each path, to reduce the gain. Attenuator 25W, 60dB (10-002960) is a fixed attenuator providing 60dB of signal attenuation.  10-002960 Specification  PARAMETER  SPECIFICATION Frequency Range DC to 2.5GHz Power Handling 25 W Attenuation 60 dB Attenuation Accuracy ± 0.5dB Return Loss to 2.2GHz 18dB Nominal Impedance 50 Ω RF Conectors N male to N female Finish  Matt Black Anodise operational -20%C to +55%C Temperature range  storage -20%C to +70%C
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 251 of 500   15  ATTENUATOR SHELF (ITAC) 3 (55-165506)     Attenuator Shelf (ITAC) 3 (55-165506) list of major components   Section  Component Part  Component Part Description  Qty. Per Assembly 15.3.1. 05-002602  900MHz Splitter/Combiner  1 15.3.2.  05-003007  4 Port Hybrid Coupler  1 15.3.3. 09-000902  Dummy load  1 15.3.4.  10-000901  Switched Attenuator 0.25W, 0 - 15dB  1 15.3.5.  10-002960  Attenuator 25W, 60dB  1
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 252 of 500   15.1. Attenuator Shelf (ITAC) 3 (55-165506) outline drawing  Drawing number 55-1655106
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 253 of 500   15.2  Attenuator Shelf (ITAC) 3 (55-165506) system diagram  Drawing number 55-165586
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 254 of 500   15.3. Attenuator Shelf (ITAC) 3 (55-165506) major components  15.3.1.  900MHz Splitter/Combiner (05-002602)  The Splitter/Combiner used is a device for accurately matching two or more RF signals to single or multiple ports, whilst maintaining an accurate 50Ω load to all inputs/outputs and ensuring that the VSWR and insertion losses are kept to a minimum. Any unused ports should be terminated with an appropriate 50Ω load. Being passive devices, the splitters should have an extremely long operational life and require no maintenance. Should a unit be suspect, it is usually most time efficient to replace the whole module rather than attempt repair or re-tuning.  05-002602 Specification  PARAMETER  SPECIFICATION Narrowband 815 – 960MHz Frequency range  Broadband 800 – 1200MHz Narrowband 145MHz Bandwidth  Broadband 400MHz Input ports 1 Output ports 2 Narrowband 3.3dB Insertion loss  Broadband 3.5dB Return loss input & output 1.3:1 Impedance 50Ω Narrowband >20dB Isolation  Broadband >18dB MTFB >180,000 hours Splitting 20Watts Power rating  Combining 0.5Watt Connectors SMA female Weight 200g (approximately) Size 54 x 44 x 21mm    15.3.2.  4 Port Hybrid Coupler (05-003007)  This transmitter hybrid coupler is a device for accurately matching two or more RF signals to single or multiple ports, whilst maintaining an accurate 50Ω load to all inputs/outputs and ensuring that the insertion losses are kept to a minimum. Any unused ports should be terminated with an appropriate 50Ω load. In this specific instance one port of 4 Port Hybrid Coupler (05-003007) is terminated with Dummy load 09-000902 (see below).  05-003007 Specification  PARAMETER  SPECIFICATION Frequency range: 700-900MHz Bandwidth: 200MHz Rejection: >14dB Insertion loss: 6.5dB (in band, typical) Connectors: SMA Weight: <1.0kg operational:-10%C to +60%C Temperature range:  storage -20%C to +70%C
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 255 of 500   15.3.3.  Dummy Load (09-000902)  When a combiner system is used to split or combine RF signals, in many cases it is most cost effective to use a standard stock item 4, 6 or 8 port device where, in fact, only a 3 or 6 port device is needed. In this case 4 Port Hybrid Coupler (05-003007) has one of its ports terminated with Dummy load (09-000902) in order to preserve the correct impedance of the device over the specified frequency range.  09-000902 specification  PARAMETER  SPECIFICATION Frequency Range 0 - 2500 MHz Power Rating 25 Watts continuous VSWR Better than 1.1:1 Impedance 50 Ohms Temperature Range -20 to +60°C RF Connectors N Type female Dimension 110.3mm x 38.1mm x Weight 485 grams Finish Black Anodised RF Connector N Type male Environmental IP66 MTBF >180,000 hours   15.3.4.  Switched Attenuator 0.25W, 0 - 15dB (10-000901)  In many practical applications for Cell Enhancers etc., the gain in each path is found to be excessive. Therefore, provision is made within the unit for the setting of attenuation in each path, to reduce the gain.  10-000901 provides attenuation from 0 - 15dB in 2 dB steps The attenuation is simply set using the four miniature toggle switches on the top of each unit. Each switch is clearly marked with the attenuation it provides, and the total attenuation in line is the sum of the values switched in. They are designed to maintain an accurate 50Ω impedance over their operating frequency at both input and output.  10-000901 Specification  PARAMETER  SPECIFICATION Attenuation Values 0-15dB Attenuation Steps 1, 2, 4 and 8dB Power Handling 0.25 Watt Attenuation Accuracy ± 1.0 dB Frequency Range DC to 1GHz Impedance 50Ω Connectors SMA VSWR 1.3:1 Weight 0.2kg operation -20°C to +60°C Temperature range  storage -40°C to +70°C
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 256 of 500   15.3.5.  Attenuator 25W, 60dB (10-002960)   In many practical applications for Cell Enhancers etc., the gain in each path is found to be excessive. Therefore, provision is made within the unit for the setting of attenuation in each path, to reduce the gain. Attenuator 25W, 60dB (10-002960) is a fixed attenuator providing 60dB of signal attenuation.  10-002960 Specification  PARAMETER  SPECIFICATION Frequency Range DC to 2.5GHz Power Handling 25 W Attenuation 60 dB Attenuation Accuracy ± 0.5dB Return Loss to 2.2GHz 18dB Nominal Impedance 50 Ω RF Conectors N male to N female Finish  Matt Black Anodise operational -20%C to +55%C Temperature range  storage -20%C to +70%C
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 257 of 500   16.  CONVENTION PLACE STATION LINE AMPLIFIER (80-330556)   C01-CR-05 Description of Convention Place Station Line Amp. (80-330556)  From the top of the rack  55-165709 55-165703 55-165704           Convention Place Station Line Amp. (80-330556) list of major components  Section  Component Part  Component Part Description  Qty. Per Assembly 16.3.1.  55-165703  800MHz Line Amplifier   1 16.3.2.  55-165704  700MHz LINE AMP + FILTERS (INT AMP)  1 16.3.3.  55-165709  Convention Place Station Splitter  1
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 258 of 500   16.1. Convention Place Station Line Amp. (80-330556) Rack elevation  Drawing number 80-330556
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 259 of 500   16.2. Convention Place Station Line Amp. (80-330556) System diagram Drawing number 80-330586
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 260 of 500   16.3. Convention Place Station Line Amp. (80-330556) Alarm wiring diagram Drawing number 80-330526
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 261 of 500   16.4 Convention Place Station Line Amp. (80-330556) Sub Components  16.4.1.  800MHz Line Amplifier (55-165703)        800MHz Line Amplifier (55-165703) List of Major Components  800MHz Line Amplifier (55-165703) List of Major Components  Section  Component Part  Component Part Description  Qty. Per Assembly 16.4.1.3. 02-007206 Bandpass Filter  4 16.4.1.4.  07-015105  Wideband Asymmetric Coupler  1 16.4.1.5.  10-000901  Switched Attenuator 0.25W, 0 - 15dB  2 16.4.1.6.  11-006702  Low Noise Amplifier  1 16.4.1.7.  12-018002  Power Amplifier (20W 800MHz )  1 16.4.1.8.  12-021901  Low Power Amplifier  2 17-001109*  AGC Detector Assembly (Logarithmic)  1 17-001117*  AGC Detector Assembly  1 16.4.1.9. 17-001201*  AGC Attenuator Assembly  2 16.4.1.10.  20-001601  12V (Dual) Relay Board  1 16.4.1.11.  80-008901  12V (Single) Relay Board  1 16.4.1.12.  94-100004  Dual Diode Assembly  1 16.4.1.13. 96-200047  DC/DC Converter  1 16.4.1.14.  96-300052  12V Switch-Mode PSU  1   *The sub components 17-001109, 17-001117 & 17-001201 are parts of the Automatic Gain Control (AGC) system used in 800MHz Line Amplifier (55-165703); 17-001117 and 17-001201 are paired for use in the uplink and 17-001109 and 17-001201 are paired for use in the downlink
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 262 of 500   16.4.1.1.  800MHz Line Amplifier (55-165703) Outline Drawing Drawing number 55-1657103
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 263 of 500   16.4.1.2.  800MHz Line Amplifier (55-165703) System Diagram  Drawing number 55-165783
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 264 of 500   16.4.1.3.  Bandpass Filter (02-007206)  The bandpass filters are multi-section designs with a bandwidth dependent upon the passband frequencies, (both tuned to customer requirements). The response shape is basically Chebyshev with a passband design ripple of 0.1dB. The filters are of slot coupled, folded combline design, and are carefully aligned during manufacture in order to optimise the insertion loss, VSWR and intermodulation characteristics of the unit. The tuned elements are silver-plated to reduce surface ohmic losses and maintain a good VSWR figure and 50Ω load at the input and output ports.  Being passive devices, the bandpass filters should have an extremely long operational life and require no maintenance. Should a filter be suspect, it is usually most time efficient to replace the module rather than attempt repair or re-tuning.  No adjustments should be attempted without full network sweep analysis facilities to monitor both insertion loss and VSWR simultaneously.  02-007206 Specification  PARAMETER  SPECIFICATION Response type Chebyshev Frequency range 800 - 950MHz * Bandwidth 25MHz * Number of sections 8 Insertion loss 1.2 dB VSWR better than 1.2:1 Connectors SMA female Power handling 100W max operation -20°C to +60°C Temperature range  storage -40°C to +70°C Weight 3 kg (typical)  *tuned to Customer's specification    16.4.1.4. Wideband Asymmetric Coupler (07-015105)  The purpose of Wideband Asymmetric Coupler (07-015105) is to tap off a known portion (in this case 30dB) of RF signal from transmission lines and to combine them, for example through splitter units for different purposes (alarms/monitoring etc.), whilst maintaining an accurate 50Ω load to all ports/interfaces throughout the specified frequency range. They are known formally as directional couplers as they couple power from the RF mainline in one direction only.   07-015105 Specification  PARAMETER  SPECIFICATION Construction Inductive air gap Frequency 800-2500MHz Through loss 0.4dB (typical) Coupling level -30dB ±0.5dB Isolation N/A Weight <1.0kg Connectors SMA, female operation -20°C to +60°C Temperature range  storage -40°C to +70°C
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 265 of 500   16.4.1.5. Switched Attenuator 0.25W, 0 - 15dB (10-000901)  In many practical applications for Cell Enhancers etc., the gain in each path is found to be excessive. Therefore, provision is made within the unit for the setting of attenuation in each path, to reduce the gain.  10-000901 provides attenuation from 0 - 15dB in 2 dB steps The attenuation is simply set using the four miniature toggle switches on the top of each unit. Each switch is clearly marked with the attenuation it provides, and the total attenuation in line is the sum of the values switched in. They are designed to maintain an accurate 50Ω impedance over their operating frequency at both input and output.  10-000901 Specification  PARAMETER  SPECIFICATION Attenuation Values 0-15dB Attenuation Steps 1, 2, 4 and 8dB Power Handling 0.25 Watt Attenuation Accuracy ± 1.0 dB Frequency Range DC to 1GHz Impedance 50Ω Connectors SMA VSWR 1.3:1 Weigh 0.2kg operation -20°C to +60°C Temperature range  storage -40°C to +70°C    16.4.1.6.  Low Noise Amplifier (11-006702)  The Gallium-Arsenide low noise amplifiers used in 800MHz Line Amplifier (55-165703) are double stage, solid-state low noise amplifiers. Class A circuitry is used throughout the units to ensure excellent linearity and extremely low noise over a very wide dynamic range. The active devices are very moderately rated to provide a long trouble-free working life. There are no adjustments on these amplifiers, and in the unlikely event of a failure, then the complete amplifier should be replaced. This amplifier features its own in-built alarm system which gives a volt-free relay contact type alarm that is easily integrated into the main alarm system.  11-006702 Specification  PARAMETER  SPECIFICATION Frequency range: 800 – 1000MHz Bandwidth: <200MHz Gain: 29dB (typical) 1dB Compression point: 20dBm OIP3: 33dBm Input/Output return loss: >18dB Noise figure: 1.3dB (typical) Power consumption: 180mA @ 24V DC Supply voltage: 10-24V DC Connectors: SMA female operational: -10°C to +60°C Temperature range:  storage: -20°C to +70°C Size: 90 x 55 x 30.2mm Weight: 290gms (approximately)
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 266 of 500  7 8 961 2 3 4 59-Way Pin-Out Graphical Representation Low Noise Amplifier (11-006702) ‘D’ Connector Pin-out details  Connector pin  Signal 1  +Ve input (10-24V) 2 GND 3  Alarm RelayO/P bad 4  Alarm Relay common 5  Alarm Relay good 6 No connection 7  TTL voltage set 8  TTL alarm/0V (good) 9  O/C good/0V bad                    16.4.1.7.  Power Amplifier (12-018002)  This amplifier is a Class A 20W power amplifier from 800-960MHz in a 1 stage balanced configuration. It demonstrates a very high linearity and a very good input/output return loss (RL). It has built in a Current Fault Alarm Function. Its housing is an aluminium case (Iridite NCP finish) with SMA connectors for the RF input/output and a D-Type connector for the power supply and the Current Fault Alarm Function.  12-018002 Specification  PARAMETER  SPECIFICATION Frequency range: 800-960MHz Small signal gain: 30dB Gain flatness: ±1.2dB I/O Return loss: >18dB 1dB compression point: 42.8dBm OIP3: 56dBm Supply voltage: 24V DC Supply current: 5.0Amps (Typical) operational: -10°C to +60°C Temperature range  storage: -20°C to +70°C Weight: <2kg (no heatsink)
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 267 of 500   Power Amplifier (12-018002) 7-Way Connector Pin-outs  Connector Pin  Signal A1 (large pin)  +24V DC A2 (large pin)  GND 1  Alarm relay common 2  TTL alarm/0V good 3  Alarm relay contact (bad) 4  Alarm relay contact (good) 5  O/C good/0V bad (TTL)                  16.4.1.8.  Low Power Amplifier (12-021901)  The low power amplifier used is a triple stage solid-state low-noise amplifier. Class A circuitry is used in the unit to ensure excellent linearity over a very wide dynamic range. The three active devices are very moderately rated to provide a long trouble-free working life.  Its housing is an aluminium case (Iridite NCP finish) with SMA connectors for the RF input/output and a D-Type connector for the power supply and the Current Fault Alarm Function. There are no adjustments on this amplifier, and in the unlikely event of failure then the entire amplifier should be replaced.  Low Power Amplifier (12-021901) Specification  PARAMETER  SPECIFICATION Frequency range 800-960MHz* Bandwidth 20MHz * Maximum RF output >1.0 Watt Gain 15dB 1dB compression point +30.5dBm 3rd order intercept point +43dBm Noise Figure <6dB VSWR better than 1.5:1 Connectors SMA female Supply 500mA @ 10-15V DC operational -10°C to +60°C Temperature range  storage -20°C to +70°C Weight 0.5 kg Size 167x52x25mm * Tuned to Customer’s specification
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 268 of 500   Low Power Amplifier (12-021901) 7-Way Connector Pin-outs  Connector Pin  Signal A1 (large pin)  +24V DC A2 (large pin)  GND 1  Alarm relay common 2  TTL alarm/0V good 3  Alarm relay contact (bad) 4  Alarm relay contact (good) 5  O/C good/0V bad (TTL)               16.4.1.9.  Automatic Gain Control  17-001109  AGC Detector Assembly (Logarithmic) 17-001117  AGC Detector Assembly  17-001201  AGC Attenuator Assembly   The sub components 17-001109, 17-001117 & 17-001201 are parts of the Automatic Gain Control (AGC) system used in 800MHz Line Amplifier (55-165703); 17-001117 and 17-001201 are paired for use in the uplink and 17-001109 and 17-001201 are paired for use in the downlink  800MHz Line Amplifier (55-165703) is fitted with two differing types of Automatic Gain Control (AGC) system, one linear, and one logarithmic. The AGC with logarithmic detector (17-001117) is fitted in the uplink path and the AGC with linear detector (17-001109) is fitted in the downlink path   The AFL Automatic Gain Control system consists of two units, a detector/amplifier and an attenuator. The detector/amplifier unit is inserted in the RF path on the output of the power amplifier, and the attenuator is situated in the RF path between the 1st and 2nd stages of amplification.  17-001117 and 17-001201 are paired for use in the uplink and 17-001109 and 17-001201 are paired for use in the downlink  The attenuator comprises a 50Ω P.I.N diode, voltage-variable attenuator with a range of 3 to 30dB. The attenuation is controlled by a DC voltage which is derived from the associated detector controller board.  Normally the attenuator is at minimum attenuation. The detector/amplifier unit monitors the RF level being delivered by the power amplifier, and when a certain threshold is reached it begins to increase the value of the attenuator to limit the RF output to the (factory set) threshold. Therefore overloading of the power amplifier is avoided.  The factory set threshold is 1dB below the Enhancer 1dB compression point. Some adjustment of this AGC threshold level is possible, a 10dB range is mostly achieved. It is not recommended under any circumstances to adjust the AGC threshold to a level greater than the 1dB compression point as system degradation will occur.
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 269 of 500   The detector comprises of a 50Ω transmission line with a resistive tap which samples a small portion of the mainline power. The sampled signal is amplified and fed to a conventional half wave diode rectifier, the output of which is a DC voltage proportional to the RF input signal.  This DC voltage is passed via an inverting DC amplifier with integrating characteristics, to the output, which drives the attenuation control line of the corresponding AGC attenuator. This unit is fitted at some earlier point in the RF circuit.  For small signals, below AGC onset, the output control line will be close to 12V and the AGC attenuator will have minimum attenuation. As the signal level increases the control line voltage will fall, increasing the attenuator value and keeping the system output level at a constant value.  AGC Specification (both types)  PARAMETER  SPECIFICATION Frequency range up to 1000MHz Attenuation range 3 to 30dB  Attenuation steps continuously variable VSWR better than 1.2:1 RF Connectors SMA female attenuator 1W Power handling  detector/amp >30W (or as required) operation -10°C to +60°C Temperature range  storage -20°C to +70°C attenuator pcb 50 x 42 x 21mm Size  detector/amp pcb 54 x 42 x 21mm attenuator 90grams Weight  detector/amp 100grams   16.4.1.10. 12V (Dual) Relay Board (20-001601)  The General Purpose Relay Board allows the inversion of signals and the isolation of circuits. It is equipped with two dual pole change-over relays with completely isolated wiring, accessed via screw terminals. Both relays are provided with polarity protection diodes and diodes for suppressing the transients caused by "flywheel effect" which can destroy switching transistors or induce spikes on neighbouring circuits. It’s common use is to amalgamate all the alarm signals into one, volts-free relay contact pair for the main alarm system.  20-001601 Specification  PARAMETER  SPECIFICATION Operating voltage: 8 to 30V (floating earth) Alarm threshold: Vcc - 1.20 volt +15% Alarm output relay contacts: Max. switch current: 1.0Amp Max. switch volts: 120Vdc/60VA Max. switch power: 24W/60VA Min. switch load: 10.0µA/10.0mV Relay isolation: 1.5kV Mechanical life: >2x107 operations Relay approval: BT type 56 Connector details: Screw terminals operational: -10°C to +60°C Temperature range  storage: -20°C to +70°C
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 270 of 500   16.4.1.11. 12V (Single) Relay Board (80-008901)  The General Purpose Relay Board allows the inversion of signals and the isolation of circuits. It is equipped with a single dual pole change-over relay RL1, with completely isolated wiring, accessed via a 15 way in-line connector.  The relay is provided with polarity protection diodes and diodes for suppressing the transients caused by "flywheel effect" which can destroy switching transistors or induce spikes on neighbouring circuits. It’s common use is to amalgamate all the alarm signals into one, volts-free relay contact pair for the main alarm system.  80-008901 Specification  PARAMETER  SPECIFICATION Operating voltage 8 to 30V (floating earth) Alarm threshold Vcc - 1.20 volt +15% Alarm output relay contacts: Max. switch current 1.0Amp Max. switch volts 120Vdc/60VA Max. switch power 24W/60VA Min. switch load 10.0µA/10.0mV Relay isolation 1.5kV Mechanical life >2x107 operations Relay approval BT type 56 Connector details Screw terminals operational -10°C to +60°C Temperature range  storage -20°C to +70°C    16.4.1.12. Dual Diode Assembly (94-100004)  The purpose of these dual diode assemblies is to allow two DC voltage sources to be combined, so that the main DC rail within the equipment can be sourced from either a mains driven PSU, or externally through an XLR connector or from dual mains driven PSUs . They are very heavy-duty diodes and they prevent any reverse current from flowing back to their source or the alternative supply rail. Combining diodes such as these will also be used if the equipment is to be powered from external back-up batteries.
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 271 of 500   16.4.1.13. DC/DC Converter 96-200047  96-200047 is an O.E.M. high power device with a wide input range and 12.5 amp @ 12V (150Watts) output capability used to derive a 12V fixed voltage power supply rail from a higher voltage supply, in this case 12V. In the event of failure this unit should not be repaired, only replaced.  96-200047 Specification  PARAMETER  SPECIFICATION DC Input Voltage range 19 to 36V DC Output voltage 12V ± 1% Max. current load 12.5Amps Operation -10°C to +60°C Temperature range  Storage -20°C to +85°C Working Humidity 20 to 90% RHNC    16.4.1.14. 12V Switch-Mode PSU (96-300052)  No routine maintenance of the PSU is required. If a fault is suspected, then the output voltage from the power supply may be measured on its output terminals. This is typically set to 12.2V. The adjustment potentiometer will be found close to the DC output terminals.  All the PSUs used in AFL Cell Enhancers are capable of operation from either 110 or 220V nominal AC supplies. The line voltage is sensed automatically, so no adjustment or link setting is needed by the operator.  96-300052 Specification  AC Input Supply  110 or 220V nominal Voltage 85 - 265V AC  (absolute limits) Frequency 47 to 63Hz DC Output Supply  12V DC (nominal) Voltage 10.5-13.8V (absolute limits) Current 12.5A
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 272 of 500    16.4.2  700MHz Line Amplifier (55-165704)     Description of 700MHz Line Amplifier (55-165704)         700MHz Line Amplifier (55-165704) List of Major Components  Section  Component Part  Component Part Description  Qty. Per Assembly 16.4.2.3. 02-007206  Bandpass Filter  4 16.4.2.4.  07-015105  Wideband Asymmetric Coupler  1 16.4.2.5.  10-000901  Switched Attenuator 0.25W, 0 - 15dB  2 16.4.2.6.  11-006702  Low Noise Amplifier  1 16.4.2.7.  12-018002  Power Amplifier (20W 800MHz )  1 16.4.2.8.  12-021901  Low Power Amplifier  2 17-001109*  AGC Detector Assembly (Logarithmic)  1 17-001117*  AGC Detector Assembly  1 16.4.2.9. 17-001201*  AGC Attenuator Assembly  2 16.4.2.10.  80-008901  12V (Single) Relay Board  1 16.4.2.11.  94-100004  Dual Diode Assembly  1 16.4.2.12. 96-200047  DC/DC Converter  1 16.4.2.13.  96-300052  12V Switch-Mode PSU  1  *The sub components 17-001109, 17-001117 & 17-001201 are parts of the Automatic Gain Control (AGC) system used in 800MHz Line Amplifier (55-165703); 17-001117 and 17-001201 are paired for use in the uplink and 17-001109 and 17-001201 are paired for use in the downlink
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 273 of 500   16.4.2.1.  700MHz Line Amplifier (55-165704) Outline Drawing  Drawing number 55-1657104
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 274 of 500   16.4.2.2.  700MHz Line Amplifier (55-165704) System Diagram  Drawing number 55-165784
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 275 of 500   16.4.2.3.  Bandpass Filter (02-007206)  The bandpass filters are multi-section designs with a bandwidth dependent upon the passband frequencies, (both tuned to customer requirements). The response shape is basically Chebyshev with a passband design ripple of 0.1dB. The filters are of slot coupled, folded combline design, and are carefully aligned during manufacture in order to optimise the insertion loss, VSWR and intermodulation characteristics of the unit. The tuned elements are silver-plated to reduce surface ohmic losses and maintain a good VSWR figure and 50Ω load at the input and output ports.  Being passive devices, the bandpass filters should have an extremely long operational life and require no maintenance. Should a filter be suspect, it is usually most time efficient to replace the module rather than attempt repair or re-tuning.  No adjustments should be attempted without full network sweep analysis facilities to monitor both insertion loss and VSWR simultaneously.  02-007206 Specification  PARAMETER  SPECIFICATION Response type Chebyshev Frequency range 800 - 950MHz * Bandwidth 25MHz * Number of sections 8 Insertion loss 1.2 dB VSWR better than 1.2:1 Connectors SMA female Power handling 100W max operation -20°C to +60°C Temperature range  storage -40°C to +70°C Weight 3 kg (typical)  *tuned to Customer's specification    16.4.2.4. Wideband Asymmetric Coupler (07-015105)  The purpose of Wideband Asymmetric Coupler (07-015105) is to tap off a known portion (in this case 30dB) of RF signal from transmission lines and to combine them, for example through splitter units for different purposes (alarms/monitoring etc.), whilst maintaining an accurate 50Ω load to all ports/interfaces throughout the specified frequency range. They are known formally as directional couplers as they couple power from the RF mainline in one direction only.   07-015105 Specification  PARAMETER  SPECIFICATION Construction Inductive air gap Frequency 800-2500MHz Through loss 0.4dB (typical) Coupling level -30dB ±0.5dB Isolation N/A Weight <1.0kg Connectors SMA, female operation -20°C to +60°C Temperature range  storage -40°C to +70°C
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 276 of 500   16.4.2.5. Switched Attenuator 0.25W, 0 - 15dB (10-000901)  In many practical applications for Cell Enhancers etc., the gain in each path is found to be excessive. Therefore, provision is made within the unit for the setting of attenuation in each path, to reduce the gain.  10-000901 provides attenuation from 0 - 15dB in 2 dB steps The attenuation is simply set using the four miniature toggle switches on the top of each unit. Each switch is clearly marked with the attenuation it provides, and the total attenuation in line is the sum of the values switched in. They are designed to maintain an accurate 50Ω impedance over their operating frequency at both input and output.  10-000901 Specification  PARAMETER  SPECIFICATION Attenuation Values 0-15dB Attenuation Steps 1, 2, 4 and 8dB Power Handling 0.25 Watt Attenuation Accuracy ± 1.0 dB Frequency Range DC to 1GHz Impedance 50Ω Connectors SMA VSWR 1.3:1 Weigh 0.2kg operation -20°C to +60°C Temperature range  storage -40°C to +70°C    16.4.2.6.  Low Noise Amplifier (11-006702)  The Gallium-Arsenide low noise amplifiers used in 700MHz Line Amplifier (55-165704) are double stage, solid-state low noise amplifiers. Class A circuitry is used throughout the units to ensure excellent linearity and extremely low noise over a very wide dynamic range. The active devices are very moderately rated to provide a long trouble-free working life. There are no adjustments on these amplifiers, and in the unlikely event of a failure, then the complete amplifier should be replaced. This amplifier features its own in-built alarm system which gives a volt-free relay contact type alarm that is easily integrated into the main alarm system.  11-006702 Specification  PARAMETER  SPECIFICATION Frequency range: 800 – 1000MHz Bandwidth: <200MHz Gain: 29dB (typical) 1dB Compression point: 20dBm OIP3: 33dBm Input/Output return loss: >18dB Noise figure: 1.3dB (typical) Power consumption: 180mA @ 24V DC Supply voltage: 10-24V DC Connectors: SMA female operational: -10°C to +60°C Temperature range:  storage: -20°C to +70°C Size: 90 x 55 x 30.2mm Weight: 290gms (approximately)
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 277 of 500  7 8 961 2 3 4 59-Way Pin-Out Graphical Representation Low Noise Amplifier (11-006702) ‘D’ Connector Pin-out details  Connector pin  Signal 1  +Ve input (10-24V) 2 GND 3  Alarm RelayO/P bad 4  Alarm Relay common 5  Alarm Relay good 6 No connection 7  TTL voltage set 8  TTL alarm/0V (good) 9  O/C good/0V bad                    16.4.2.7.  Power Amplifier (12-018002)  This amplifier is a Class A 20W power amplifier from 800-960MHz in a 1 stage balanced configuration. It demonstrates a very high linearity and a very good input/output return loss (RL). It has built in a Current Fault Alarm Function. Its housing is an aluminium case (Iridite NCP finish) with SMA connectors for the RF input/output and a D-Type connector for the power supply and the Current Fault Alarm Function.  Technical Specification  PARAMETER  SPECIFICATION Frequency range: 800-960MHz Small signal gain: 30dB Gain flatness: ±1.2dB I/O Return loss: >18dB 1dB compression point: 42.8dBm OIP3: 56dBm Supply voltage: 24V DC Supply current: 5.0Amps (Typical) operational: -10°C to +60°C Temperature range  storage: -20°C to +70°C Weight: <2kg (no heatsink)
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 278 of 500   Power Amplifier (12-018002) 7-Way Connector Pin-outs  Connector Pin  Signal A1 (large pin)  +24V DC A2 (large pin)  GND 1  Alarm relay common 2  TTL alarm/0V good 3  Alarm relay contact (bad) 4  Alarm relay contact (good) 5  O/C good/0V bad (TTL)                  16.4.2.8.  Low Power Amplifier (12-021901)  The low power amplifier used is a triple stage solid-state low-noise amplifier. Class A circuitry is used in the unit to ensure excellent linearity over a very wide dynamic range. The three active devices are very moderately rated to provide a long trouble-free working life.  Its housing is an aluminium case (Iridite NCP finish) with SMA connectors for the RF input/output and a D-Type connector for the power supply and the Current Fault Alarm Function. There are no adjustments on this amplifier, and in the unlikely event of failure then the entire amplifier should be replaced.  Low Power Amplifier (12-021901) Specification  PARAMETER  SPECIFICATION Frequency range 800-960MHz* Bandwidth 20MHz * Maximum RF output >1.0 Watt Gain 15dB 1dB compression point +30.5dBm 3rd order intercept point +43dBm Noise Figure <6dB VSWR better than 1.5:1 Connectors SMA female Supply 500mA @ 10-15V DC operational -10°C to +60°C Temperature range  storage -20°C to +70°C Weight 0.5 kg Size 167x52x25mm * Tuned to Customer’s specification
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 279 of 500   Low Power Amplifier (12-021901) 7-Way Connector Pin-outs  Connector Pin  Signal A1 (large pin)  +24V DC A2 (large pin)  GND 1  Alarm relay common 2  TTL alarm/0V good 3  Alarm relay contact (bad) 4  Alarm relay contact (good) 5  O/C good/0V bad (TTL)               16.4.2.9.  Automatic Gain Control  17-001109  AGC Detector Assembly (Logarithmic) 17-001117  AGC Detector Assembly  17-001201  AGC Attenuator Assembly   The sub components 17-001109, 17-001117 & 17-001201 are parts of the Automatic Gain Control (AGC) system used in 700MHz Line Amplifier (55-165704); 17-001117 and 17-001201 are paired for use in the uplink and 17-001109 and 17-001201 are paired for use in the downlink  700MHz Line Amplifier (55-165704) is fitted with two differing types of Automatic Gain Control (AGC) system, one linear, and one logarithmic. The AGC with logarithmic detector (17-001117) is fitted in the uplink path and the AGC with linear detector (17-001109) is fitted in the downlink path   The AFL Automatic Gain Control system consists of two units, a detector/amplifier and an attenuator. The detector/amplifier unit is inserted in the RF path on the output of the power amplifier, and the attenuator is situated in the RF path between the 1st and 2nd stages of amplification.  17-001117 and 17-001201 are paired for use in the uplink and 17-001109 and 17-001201 are paired for use in the downlink  The attenuator comprises a 50Ω P.I.N diode, voltage-variable attenuator with a range of 3 to 30dB. The attenuation is controlled by a DC voltage which is derived from the associated detector controller board.  Normally the attenuator is at minimum attenuation. The detector/amplifier unit monitors the RF level being delivered by the power amplifier, and when a certain threshold is reached it begins to increase the value of the attenuator to limit the RF output to the (factory set) threshold. Therefore overloading of the power amplifier is avoided.  The factory set threshold is 1dB below the Enhancer 1dB compression point. Some adjustment of this AGC threshold level is possible, a 10dB range is mostly achieved. It is not recommended under any circumstances to adjust the AGC threshold to a level greater than the 1dB compression point as system degradation will occur.
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 280 of 500   The detector comprises of a 50Ω transmission line with a resistive tap which samples a small portion of the mainline power. The sampled signal is amplified and fed to a conventional half wave diode rectifier, the output of which is a DC voltage proportional to the RF input signal.  This DC voltage is passed via an inverting DC amplifier with integrating characteristics, to the output, which drives the attenuation control line of the corresponding AGC attenuator. This unit is fitted at some earlier point in the RF circuit.  For small signals, below AGC onset, the output control line will be close to 12V and the AGC attenuator will have minimum attenuation. As the signal level increases the control line voltage will fall, increasing the attenuator value and keeping the system output level at a constant value.  AGC Specification (both types)  PARAMETER  SPECIFICATION Frequency range up to 1000MHz Attenuation range 3 to 30dB  Attenuation steps continuously variable VSWR better than 1.2:1 RF Connectors SMA female attenuator 1W Power handling  detector/amp >30W (or as required) operation -10°C to +60°C Temperature range  storage -20°C to +70°C attenuator pcb 50 x 42 x 21mm Size  detector/amp pcb 54 x 42 x 21mm attenuator 90grams Weight  detector/amp 100grams   16.4.2.10. 12V (Single) Relay Board (80-008901)  The General Purpose Relay Board allows the inversion of signals and the isolation of circuits. It is equipped with a single dual pole change-over relay RL1, with completely isolated wiring, accessed via a 15 way in-line connector.  The relay is provided with polarity protection diodes and diodes for suppressing the transients caused by "flywheel effect" which can destroy switching transistors or induce spikes on neighbouring circuits. It’s common use is to amalgamate all the alarm signals into one, volts-free relay contact pair for the main alarm system.  80-008901 Specification  PARAMETER  SPECIFICATION Operating voltage 8 to 30V (floating earth) Alarm threshold Vcc - 1.20 volt +15% Alarm output relay contacts: Max. switch current 1.0Amp Max. switch volts 120Vdc/60VA Max. switch power 24W/60VA Min. switch load 10.0µA/10.0mV Relay isolation 1.5kV Mechanical life >2x107 operations Relay approval BT type 56 Connector details Screw terminals operational -10°C to +60°C Temperature range  storage -20°C to +70°C
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 281 of 500   16.4.2.11. Dual Diode Assembly (94-100004)  The purpose of these dual diode assemblies is to allow two DC voltage sources to be combined, so that the main DC rail within the equipment can be sourced from either a mains driven PSU, or externally through an XLR connector or from dual mains driven PSUs . They are very heavy-duty diodes and they prevent any reverse current from flowing back to their source or the alternative supply rail. Combining diodes such as these will also be used if the equipment is to be powered from external back-up batteries.   16.4.2.12. DC/DC Converter 96-200047  96-200047 is an O.E.M. high power device with a wide input range and 12.5 amp @ 12V (150Watts) output capability used to derive a 12V fixed voltage power supply rail from a higher voltage supply, in this case 12V. In the event of failure this unit should not be repaired, only replaced.  96-200047 Specification  PARAMETER  SPECIFICATION DC Input Voltage range 19 to 36V DC Output voltage 12V ± 1% Max. current load 12.5Amps Operation -10°C to +60°C Temperature range  Storage -20°C to +85°C Working Humidity 20 to 90% RHNC    16.3.2.13. 12V Switch-Mode PSU (96-300052)  No routine maintenance of the PSU is required. If a fault is suspected, then the output voltage from the power supply may be measured on its output terminals. This is typically set to 12.2V. The adjustment potentiometer will be found close to the DC output terminals.  All the PSUs used in AFL Cell Enhancers are capable of operation from either 110 or 220V nominal AC supplies. The line voltage is sensed automatically, so no adjustment or link setting is needed by the operator.  96-300052 Specification  AC Input Supply  110 or 220V nominal Voltage 85 - 265V AC  (absolute limits) Frequency 47 to 63Hz DC Output Supply  12V DC (nominal) Voltage 10.5-13.8V (absolute limits) Current 12.5A
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 282 of 500   16.4.3.  Convention Place Station Splitter (55-165709)  2U rack mount tray    Convention Place Station Splitter (55-165709) major components  Section  Component Part  Component Part Description  Qty. Per Assembly16.4.3.3. 05-002602  900MHz Splitter/Combiner  1 16.4.3.4.  07-015102  Wideband Asymmetric Coupler  2
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 283 of 500   16.4.3.1. Convention Place Station Splitter (55-165709) outline drawing Drawing number 55-1657109
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 284 of 500   16.4.3.2. Convention Place Station Splitter (55-165709) system diagram Drawing number 55-165789
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 285 of 500   16.4.3.3. 900MHz Splitter/Combiner (05-002602)  The Splitter/Combiner used is a device for accurately matching two or more RF signals to single or multiple ports, whilst maintaining an accurate 50Ω load to all inputs/outputs and ensuring that the VSWR and insertion losses are kept to a minimum. Any unused ports should be terminated with an appropriate 50Ω load. Being passive devices, the splitters should have an extremely long operational life and require no maintenance. Should a unit be suspect, it is usually most time efficient to replace the whole module rather than attempt repair or re-tuning.  05-002602 Specification  PARAMETER  SPECIFICATION Narrowband: 815 – 960MHz Frequency range:  Broadband: 800 – 1200MHz Narrowband: 145MHz Bandwidth:  Broadband: 400MHz Input ports: 1 Output ports: 2 Narrowband: 3.3dB Insertion loss:  Broadband: 3.5dB Return loss input & output: 1.3:1 Impedance: 50Ω Narrowband: >20dB Isolation:  Broadband: >18dB MTFB: >180,000 hours Splitting: 20Watts Power rating:  Combining: 0.5Watt Connectors: SMA female Weight: 200g (approximately) Size: 54 x 44 x 21mm     16.4.3.4. Wideband Asymmetric Coupler (07-015102)  The purpose of Wideband Asymmetric Coupler (07-015102) is to tap off a known portion (in this case 10dB) of RF signal from transmission lines and to combine them, for example through splitter units for different purposes (alarms/monitoring etc.), whilst maintaining an accurate 50Ω load to all ports/interfaces throughout the specified frequency range. They are known formally as directional couplers as they couple power from the RF mainline in one direction only.   07-015102 Specification  PARAMETER  SPECIFICATION Frequency Range 800 - 2500 MHz Coupling Value 10 dB ± 1.0 dB Main Line Insertion Loss <1.6 dB VSWR 1.4:1 Directivity >18 dB Power Rating 200 Watts RF Connectors ‘N’ female operation -20°C to +60°C Temperature range  storage -40°C to +70°C
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 286 of 500   17.  INTERNATIONAL (NO NPSPAC) LINE AMPLIFIER (80-330557)  Rack C09-CR-06   International (no NPSPAC) Line Amp. (80-330557) list of major components  Section  Component Part  Component Part Description  Qty. Per Assembly 17.4.1.  55-165705  800MHz Line Amplifier (NO NSP)  1 17.4.2.  55-165706  700MHz Line Amplifier (NO NSP)  1 17.4.3. 55-165710 International Station Splitter  1
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 287 of 500   17.1. International (no NPSPAC) Line Amp. (80-330557) Rack elevation Drawing number 80-330557
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 288 of 500   17.2. International (no NPSPAC) Line Amp. (80-330557) System diagram  Drawing number 80-330587
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 289 of 500   17.3. International (no NPSPAC) Line Amp. (80-330557) Alarm wiring diagram Drawing number 80-330527
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 290 of 500   17.4. International (no NPSPAC) Line Amp. (80-330557) major components  17.4.1.  800MHz Line Amplifier (no NPSPAC) (55-165705)  800MHz Line Amplifier (no NPSPAC) (55-165705) List of Major Components  section  Component Part  Component Part Description  Qty. Per Assembly17.4.1.3. 02-007201 Bandpass Filter  2 17.4.1.4. 02-007206 Bandpass Filter  2 17.4.1.5.  07-015105  Wideband Asymmetric Coupler  1 17.4.1.6.  10-000901  Switched Attenuator 0.25W, 0 - 15dB  2 17.4.1.7.  11-006702  Low Noise Amplifier  1 17.4.1.8. 12-018002 Power Amplifier  1 17.4.1.9.  12-021901  Low Power Amplifier  2 17-001109*  AGC Detector Assembly (Logarithmic)  1 17-001117*  AGC Detector Assembly  1 17.4.1.10. 17-001201*  AGC Attenuator Assembly  2 17.4.1.11.  80-008901  12V (Single) Relay Board  1 17.4.1.12.  94-100004  Dual Diode Assembly  1 17.4.1.13. 96-200047  DC/DC Converter   17.4.1.14.  96-300052  12V Switch-Mode PSU (96-300052)  1  *The sub components 17-001109, 17-001117 & 17-001201 are parts of the Automatic Gain Control (AGC) system used in 800MHz Line Amplifier (no NPSPAC) (55-165705); 17-001117 and 17-001201 are paired for use in the uplink and 17-001109 and 17-001201 are paired for use in the downlink
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 291 of 500   17.4.1.1.  800MHz Line Amplifier (no NPSPAC) (55-165705) Outline Drawing Drawing number 55-1657105
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 292 of 500   14.4.1.2.  800MHz Line Amplifier (no NPSPAC) (55-165705) System Diagram  Drawing number 55-165785
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 293 of 500   17.4.1.3.  Bandpass Filter (02-012701)  The bandpass filters are multi-section designs with a bandwidth dependent upon the passband frequencies, (both tuned to customer requirements). The response shape is basically Chebyshev with a passband design ripple of 0.1dB. The filters are of combline design and are carefully aligned during manufacture in order to optimise the insertion loss, VSWR and intermodulation characteristics of the unit. The tuned elements are silver-plated to reduce surface ohmic losses and maintain a good VSWR figure and 50Ω load at the input and output ports. Being passive devices, the bandpass filters should have an extremely long operational life and require no maintenance. Should a filter be suspect, it is usually most time efficient to replace the module rather than attempt repair or re-tuning. No adjustments should be attempted without full network sweep analysis facilities to monitor both insertion loss and VSWR simultaneously.  02-012701 Specification  PARAMETER  SPECIFICATION Frequency range 1805 – 1880 MHz * Insertion loss <0.6 dB >60 dB over 1710 – 1785 MHz Rejection >40 dB over 1905 – 2170 MHz Return loss > 20 dB Power handling 200W (CW) operation -20°C to +60°C Temperature range  storage -40°C to +70°C Size 227 x 95 x 60mm (case only) * tuned to customer’s specification   17.4.1.4.  Bandpass Filter (02-007206)  The bandpass filters are multi-section designs with a bandwidth dependent upon the passband frequencies, (both tuned to customer requirements). The response shape is basically Chebyshev with a passband design ripple of 0.1dB. The filters are of slot coupled, folded combline design, and are carefully aligned during manufacture in order to optimise the insertion loss, VSWR and intermodulation characteristics of the unit. The tuned elements are silver-plated to reduce surface ohmic losses and maintain a good VSWR figure and 50Ω load at the input and output ports. Being passive devices, the bandpass filters should have an extremely long operational life and require no maintenance. Should a filter be suspect, it is usually most time efficient to replace the module rather than attempt repair or re-tuning. No adjustments should be attempted without full network sweep analysis facilities to monitor both insertion loss and VSWR simultaneously.  02-007206 Specification PARAMETER  SPECIFICATION Response type Chebyshev Frequency range 800 - 950MHz * Bandwidth 25MHz * Number of sections 8 Insertion loss 1.2 dB VSWR better than 1.2:1 Connectors SMA female Power handling 100W max operation -20°C to +60°C Temperature range  storage -40°C to +70°C Weight 3 kg (typical)  *tuned to Customer's specification
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 294 of 500   17.4.1.5. Wideband Asymmetric Coupler (07-015105)  The purpose of Wideband Asymmetric Coupler (07-015105) is to tap off a known portion (in this case 30dB) of RF signal from transmission lines and to combine them, for example through splitter units for different purposes (alarms/monitoring etc.), whilst maintaining an accurate 50Ω load to all ports/interfaces throughout the specified frequency range. They are known formally as directional couplers as they couple power from the RF mainline in one direction only.   07-015105 Specification  PARAMETER  SPECIFICATION Construction Inductive air gap Frequency 800-2500MHz Through loss 0.4dB (typical) Coupling level -30dB ±0.5dB Isolation N/A Weight <1.0kg Connectors SMA, female operation -20°C to +60°C Temperature range  storage -40°C to +70°C     17.4.1.6. Switched Attenuator 0.25W, 0 - 15dB (10-000901)  In many practical applications for Cell Enhancers etc., the gain in each path is found to be excessive. Therefore, provision is made within the unit for the setting of attenuation in each path, to reduce the gain.  10-000901 provides attenuation from 0 - 15dB in 2 dB steps The attenuation is simply set using the four miniature toggle switches on the top of each unit. Each switch is clearly marked with the attenuation it provides, and the total attenuation in line is the sum of the values switched in. They are designed to maintain an accurate 50Ω impedance over their operating frequency at both input and output.  10-000901 Specification  PARAMETER  SPECIFICATION Attenuation Values 0-15dB Attenuation Steps 1, 2, 4 and 8dB Power Handling 0.25 Watt Attenuation Accuracy ± 1.0 dB Frequency Range DC to 1GHz Impedance 50Ω Connectors SMA VSWR 1.3:1 Weigh 0.2kg operation -20°C to +60°C Temperature range  storage -40°C to +70°C
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 295 of 500  7 8 961 2 3 4 59-Way Pin-Out Graphical Representation 17.4.1.7.  Low Noise Amplifier (11-006702)  The Gallium-Arsenide low noise amplifiers used in 800MHz Line Amplifier (55-165703) are double stage, solid-state low noise amplifiers. Class A circuitry is used throughout the units to ensure excellent linearity and extremely low noise over a very wide dynamic range. The active devices are very moderately rated to provide a long trouble-free working life. There are no adjustments on these amplifiers, and in the unlikely event of a failure, then the complete amplifier should be replaced. This amplifier features its own in-built alarm system which gives a volt-free relay contact type alarm that is easily integrated into the main alarm system.  11-006702 Specification  PARAMETER  SPECIFICATION Frequency range 800 – 1000MHz Bandwidth <200MHz Gain 29dB (typical) 1dB Compression point 20dBm OIP3 33dBm Input/Output return loss >18dB Noise figure 1.3dB (typical) Power consumption 180mA @ 24V DC Supply voltage 10-24V DC Connectors SMA female operational -10°C to +60°C Temperature range:  storage -20°C to +70°C Size 90 x 55 x 30.2mm Weight 290gms (approximately)  Low Noise Amplifier (11-006702) ‘D’ Connector Pin-out details  Connector pin  Signal 1  +Ve input (10-24V) 2 GND 3  Alarm RelayO/P bad 4  Alarm Relay common 5  Alarm Relay good 6 No connection 7  TTL voltage set 8  TTL alarm/0V (good) 9  O/C good/0V bad
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 296 of 500   17.4.1.8.  Power Amplifier (12-018002)  This amplifier is a Class A 20W power amplifier from 800-960MHz in a 1 stage balanced configuration. It demonstrates a very high linearity and a very good input/output return loss (RL). It has built in a Current Fault Alarm Function. Its housing is an aluminium case (Iridite NCP finish) with SMA connectors for the RF input/output and a D-Type connector for the power supply and the Current Fault Alarm Function.  12-018002 Specification  PARAMETER  SPECIFICATION Frequency range: 800-960MHz Small signal gain: 30dB Gain flatness: ±1.2dB I/O Return loss: >18dB 1dB compression point: 42.8dBm OIP3: 56dBm Supply voltage: 24V DC Supply current: 5.0Amps (Typical) operational: -10°C to +60°C Temperature range  storage: -20°C to +70°C Weight: <2kg (no heatsink)   Power Amplifier (12-018002) 7-Way Connector Pin-outs  Connector Pin  Signal A1 (large pin)  +24V DC A2 (large pin)  GND 1  Alarm relay common 2  TTL alarm/0V good 3  Alarm relay contact (bad) 4  Alarm relay contact (good) 5  O/C good/0V bad (TTL)
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 297 of 500   17.4.1.9.  Low Power Amplifier (12-021901)  The low power amplifier used is a triple stage solid-state low-noise amplifier. Class A circuitry is used in the unit to ensure excellent linearity over a very wide dynamic range. The three active devices are very moderately rated to provide a long trouble-free working life.  Its housing is an aluminium case (Iridite NCP finish) with SMA connectors for the RF input/output and a D-Type connector for the power supply and the Current Fault Alarm Function. There are no adjustments on this amplifier, and in the unlikely event of failure then the entire amplifier should be replaced.  Low Power Amplifier (12-021901) Specification  PARAMETER  SPECIFICATION Frequency range 800-960MHz* Bandwidth 20MHz * Maximum RF output >1.0 Watt Gain 15dB 1dB compression point +30.5dBm 3rd order intercept point +43dBm Noise Figure <6dB VSWR better than 1.5:1 Connectors SMA female Supply 500mA @ 10-15V DC operational -10°C to +60°C Temperature range  storage -20°C to +70°C Weight 0.5 kg Size 167x52x25mm * Tuned to Customer’s specification  Low Power Amplifier (12-021901) 7-Way Connector Pin-outs  Connector Pin  Signal A1 (large pin)  +24V DC A2 (large pin)  GND 1  Alarm relay common 2  TTL alarm/0V good 3  Alarm relay contact (bad) 4  Alarm relay contact (good) 5  O/C good/0V bad (TTL)
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 298 of 500   7.4.1.10.  Automatic Gain Control  17-001109  AGC Detector Assembly (Logarithmic) 17-001117  AGC Detector Assembly  17-001201  AGC Attenuator Assembly   The sub components 17-001109, 17-001117 & 17-001201 are parts of the Automatic Gain Control (AGC) system used in 800MHz Line Amplifier (no NPSPAC) (55-165705); 17-001117 and 17-001201 are paired for use in the uplink and 17-001109 and 17-001201 are paired for use in the downlink  800MHz Line Amplifier (no NPSPAC) (55-165705) is fitted with two differing types of Automatic Gain Control (AGC) system, one linear, and one logarithmic. The AGC with logarithmic detector (17-001117) is fitted in the uplink path and the AGC with linear detector (17-001109) is fitted in the downlink path   The AFL Automatic Gain Control system consists of two units, a detector/amplifier and an attenuator. The detector/amplifier unit is inserted in the RF path on the output of the power amplifier, and the attenuator is situated in the RF path between the 1st and 2nd stages of amplification.  17-001117 and 17-001201 are paired for use in the uplink and 17-001109 and 17-001201 are paired for use in the downlink  The attenuator comprises a 50Ω P.I.N diode, voltage-variable attenuator with a range of 3 to 30dB. The attenuation is controlled by a DC voltage which is derived from the associated detector controller board.  Normally the attenuator is at minimum attenuation. The detector/amplifier unit monitors the RF level being delivered by the power amplifier, and when a certain threshold is reached it begins to increase the value of the attenuator to limit the RF output to the (factory set) threshold. Therefore overloading of the power amplifier is avoided.  The factory set threshold is 1dB below the Enhancer 1dB compression point. Some adjustment of this AGC threshold level is possible, a 10dB range is mostly achieved. It is not recommended under any circumstances to adjust the AGC threshold to a level greater than the 1dB compression point as system degradation will occur.  The detector comprises of a 50Ω transmission line with a resistive tap which samples a small portion of the mainline power. The sampled signal is amplified and fed to a conventional half wave diode rectifier, the output of which is a DC voltage proportional to the RF input signal.  This DC voltage is passed via an inverting DC amplifier with integrating characteristics, to the output, which drives the attenuation control line of the corresponding AGC attenuator. This unit is fitted at some earlier point in the RF circuit.  For small signals, below AGC onset, the output control line will be close to 12V and the AGC attenuator will have minimum attenuation. As the signal level increases the control line voltage will fall, increasing the attenuator value and keeping the system output level at a constant value.
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 299 of 500   AGC Specification (both types)  PARAMETER  SPECIFICATION Frequency range up to 1000MHz Attenuation range 3 to 30dB  Attenuation steps continuously variable VSWR better than 1.2:1 RF Connectors SMA female attenuator 1W Power handling  detector/amp >30W (or as required) operation -10°C to +60°C Temperature range  storage -20°C to +70°C attenuator pcb 50 x 42 x 21mm Size  detector/amp pcb 54 x 42 x 21mm attenuator 90grams Weight  detector/amp 100grams   17.4.1.11. 12V (Single) Relay Board (80-008901)  The General Purpose Relay Board allows the inversion of signals and the isolation of circuits. It is equipped with a single dual pole change-over relay RL1, with completely isolated wiring, accessed via a 15 way in-line connector.  The relay is provided with polarity protection diodes and diodes for suppressing the transients caused by "flywheel effect" which can destroy switching transistors or induce spikes on neighbouring circuits. It’s common use is to amalgamate all the alarm signals into one, volts-free relay contact pair for the main alarm system.  80-008901 Specification  PARAMETER  SPECIFICATION Operating voltage 8 to 30V (floating earth) Alarm threshold Vcc - 1.20 volt +15% Alarm output relay contacts: Max. switch current 1.0Amp Max. switch volts 120Vdc/60VA Max. switch power 24W/60VA Min. switch load 10.0µA/10.0mV Relay isolation 1.5kV Mechanical life >2x107 operations Relay approval BT type 56 Connector details Screw terminals operational -10°C to +60°C Temperature range  storage -20°C to +70°C
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 300 of 500   17.4.1.12. Dual Diode Assembly (94-100004)  The purpose of these dual diode assemblies is to allow two DC voltage sources to be combined, so that the main DC rail within the equipment can be sourced from either a mains driven PSU, or externally through an XLR connector or from dual mains driven PSUs . They are very heavy-duty diodes and they prevent any reverse current from flowing back to their source or the alternative supply rail. Combining diodes such as these will also be used if the equipment is to be powered from external back-up batteries.   17.4.1.13. DC/DC Converter 96-200047  96-200047 is an O.E.M. high power device with a wide input range and 12.5 amp @ 12V (150Watts) output capability used to derive a 12V fixed voltage power supply rail from a higher voltage supply, in this case 12V. In the event of failure this unit should not be repaired, only replaced.  96-200047 Specification  PARAMETER  SPECIFICATION DC Input Voltage range 19 to 36V DC Output voltage 12V ± 1% Max. current load 12.5Amps Operation -10°C to +60°C Temperature range  Storage -20°C to +85°C Working Humidity 20 to 90% RHNC     17.4.1.14. 12V Switch-Mode PSU (96-300052)  No routine maintenance of the PSU is required. If a fault is suspected, then the output voltage from the power supply may be measured on its output terminals. This is typically set to 12.2V. The adjustment potentiometer will be found close to the DC output terminals.  All the PSUs used in AFL Cell Enhancers are capable of operation from either 110 or 220V nominal AC supplies. The line voltage is sensed automatically, so no adjustment or link setting is needed by the operator.  96-300052 Specification  AC Input Supply  110 or 220V nominal Voltage 85 - 265V AC  (absolute limits) Frequency 47 to 63Hz DC Output Supply  12V DC (nominal) Voltage 10.5-13.8V (absolute limits) Current 12.5A
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 301 of 500   17.4.2.  700MHz Line Amplifier (no NPSPAC) (55-165706)  700MHz Line Amplifier (no NPSPAC) (55-165706) List of Major Components   Section Component Part  Component Part Description  Qty. Per Assembly 17.4.2.3. 02-007201 Bandpass Filter  2 17.4.2.4. 02-007206 Bandpass Filter  2 17.4.2.5.  07-015105  Wideband Asymmetric Coupler  1 17.4.2.6.  10-000901  Switched Attenuator 0.25W, 0 - 15dB  2 17.4.2.7.  11-006702  Low Noise Amplifier  1 17.4.2.8. 12-018002 Power Amplifier  1 17.4.1.9.  12-021901  Low Power Amplifier  2 17-001109  AGC Detector Assembly (Logarithmic)  1 17-001117  AGC Detector Assembly  1 17.4.2.10. 17-001201  AGC Attenuator Assembly  2 17.4.2.11.  80-008901  12V (Single) Relay Board  1 17.4.2.12.  94-100004  Dual Diode Assembly  1 17.4.2.13. 96-200047 DC/DC Converter   17.4.2.14.  96-300052  12V Switch-Mode PSU (96-300052)  1      *The sub components 17-001109, 17-001117 & 17-001201 are parts of the Automatic Gain Control (AGC) system used in 700MHz Line Amplifier (no NPSPAC) (55-165705); 17-001117 and 17-001201 are paired for use in the uplink and 17-001109 and 17-001201 are paired for use in the downlink
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 302 of 500   17.4.2.1.  700MHz Line Amplifier (no NPSPAC) (55-165706) Outline Drawing Drawing number 55-1657106
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 303 of 500   17.4.2.2.  700MHz Line Amplifier (no NPSPAC) (55-165706) System Diagram  Drawing number 55-165786
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 304 of 500   17.4.2.3.  Bandpass Filter (02-012701)  The bandpass filters are multi-section designs with a bandwidth dependent upon the passband frequencies, (both tuned to customer requirements). The response shape is basically Chebyshev with a passband design ripple of 0.1dB. The filters are of combline design and are carefully aligned during manufacture in order to optimise the insertion loss, VSWR and intermodulation characteristics of the unit. The tuned elements are silver-plated to reduce surface ohmic losses and maintain a good VSWR figure and 50Ω load at the input and output ports. Being passive devices, the bandpass filters should have an extremely long operational life and require no maintenance. Should a filter be suspect, it is usually most time efficient to replace the module rather than attempt repair or re-tuning. No adjustments should be attempted without full network sweep analysis facilities to monitor both insertion loss and VSWR simultaneously.  02-012701 Specification  PARAMETER  SPECIFICATION Frequency range 1805 – 1880 MHz * Insertion loss <0.6 dB >60 dB over 1710 – 1785 MHz Rejection >40 dB over 1905 – 2170 MHz Return loss > 20 dB Power handling 200W (CW) operation -20°C to +60°C Temperature range  storage -40°C to +70°C Size 227 x 95 x 60mm (case only) * tuned to customer’s specification   17.4.2.4.  Bandpass Filter (02-007206)  The bandpass filters are multi-section designs with a bandwidth dependent upon the passband frequencies, (both tuned to customer requirements). The response shape is basically Chebyshev with a passband design ripple of 0.1dB. The filters are of slot coupled, folded combline design, and are carefully aligned during manufacture in order to optimise the insertion loss, VSWR and intermodulation characteristics of the unit. The tuned elements are silver-plated to reduce surface ohmic losses and maintain a good VSWR figure and 50Ω load at the input and output ports. Being passive devices, the bandpass filters should have an extremely long operational life and require no maintenance. Should a filter be suspect, it is usually most time efficient to replace the module rather than attempt repair or re-tuning. No adjustments should be attempted without full network sweep analysis facilities to monitor both insertion loss and VSWR simultaneously.  02-007206 Specification PARAMETER  SPECIFICATION Response type Chebyshev Frequency range 800 - 950MHz * Bandwidth 25MHz * Number of sections 8 Insertion loss 1.2 dB VSWR better than 1.2:1 Connectors SMA female Power handling 100W max operation -20°C to +60°C Temperature range  storage -40°C to +70°C Weight 3 kg (typical)  *tuned to Customer's specification
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 305 of 500   17.4.2.5. Wideband Asymmetric Coupler (07-015105)  The purpose of Wideband Asymmetric Coupler (07-015105) is to tap off a known portion (in this case 30dB) of RF signal from transmission lines and to combine them, for example through splitter units for different purposes (alarms/monitoring etc.), whilst maintaining an accurate 50Ω load to all ports/interfaces throughout the specified frequency range. They are known formally as directional couplers as they couple power from the RF mainline in one direction only.   07-015105 Specification  PARAMETER  SPECIFICATION Construction Inductive air gap Frequency 800-2500MHz Through loss 0.4dB (typical) Coupling level -30dB ±0.5dB Isolation N/A Weight <1.0kg Connectors SMA, female operation -20°C to +60°C Temperature range  storage -40°C to +70°C     17.4.2.6. Switched Attenuator 0.25W, 0 - 15dB (10-000901)  In many practical applications for Cell Enhancers etc., the gain in each path is found to be excessive. Therefore, provision is made within the unit for the setting of attenuation in each path, to reduce the gain.  10-000901 provides attenuation from 0 - 15dB in 2 dB steps The attenuation is simply set using the four miniature toggle switches on the top of each unit. Each switch is clearly marked with the attenuation it provides, and the total attenuation in line is the sum of the values switched in. They are designed to maintain an accurate 50Ω impedance over their operating frequency at both input and output.  10-000901 Specification  PARAMETER  SPECIFICATION Attenuation Values 0-15dB Attenuation Steps 1, 2, 4 and 8dB Power Handling 0.25 Watt Attenuation Accuracy ± 1.0 dB Frequency Range DC to 1GHz Impedance 50Ω Connectors SMA VSWR 1.3:1 Weigh 0.2kg operation -20°C to +60°C Temperature range  storage -40°C to +70°C
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 306 of 500  7 8 961 2 3 4 59-Way Pin-Out Graphical Representation 17.4.2.7.  Low Noise Amplifier (11-006702)  The Gallium-Arsenide low noise amplifiers used in 800MHz Line Amplifier (55-165703) are double stage, solid-state low noise amplifiers. Class A circuitry is used throughout the units to ensure excellent linearity and extremely low noise over a very wide dynamic range. The active devices are very moderately rated to provide a long trouble-free working life. There are no adjustments on these amplifiers, and in the unlikely event of a failure, then the complete amplifier should be replaced. This amplifier features its own in-built alarm system which gives a volt-free relay contact type alarm that is easily integrated into the main alarm system.  11-006702 Specification  PARAMETER  SPECIFICATION Frequency range 800 – 1000MHz Bandwidth <200MHz Gain 29dB (typical) 1dB Compression point 20dBm OIP3 33dBm Input/Output return loss >18dB Noise figure 1.3dB (typical) Power consumption 180mA @ 24V DC Supply voltage 10-24V DC Connectors SMA female operational -10°C to +60°C Temperature range:  storage -20°C to +70°C Size 90 x 55 x 30.2mm Weight 290gms (approximately)  Low Noise Amplifier (11-006702) ‘D’ Connector Pin-out details  Connector pin  Signal 1  +Ve input (10-24V) 2 GND 3  Alarm RelayO/P bad 4  Alarm Relay common 5  Alarm Relay good 6 No connection 7  TTL voltage set 8  TTL alarm/0V (good) 9  O/C good/0V bad
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 307 of 500   17.4.2.8.  Power Amplifier (12-018002)  This amplifier is a Class A 20W power amplifier from 800-960MHz in a 1 stage balanced configuration. It demonstrates a very high linearity and a very good input/output return loss (RL). It has built in a Current Fault Alarm Function. Its housing is an aluminium case (Iridite NCP finish) with SMA connectors for the RF input/output and a D-Type connector for the power supply and the Current Fault Alarm Function.  12-018002 Specification  PARAMETER  SPECIFICATION Frequency range: 800-960MHz Small signal gain: 30dB Gain flatness: ±1.2dB I/O Return loss: >18dB 1dB compression point: 42.8dBm OIP3: 56dBm Supply voltage: 24V DC Supply current: 5.0Amps (Typical) operational: -10°C to +60°C Temperature range  storage: -20°C to +70°C Weight: <2kg (no heatsink)   Power Amplifier (12-018002) 7-Way Connector Pin-outs  Connector Pin  Signal A1 (large pin)  +24V DC A2 (large pin)  GND 1  Alarm relay common 2  TTL alarm/0V good 3  Alarm relay contact (bad) 4  Alarm relay contact (good) 5  O/C good/0V bad (TTL)
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 308 of 500   17.4.2.9.  Low Power Amplifier (12-021901)  The low power amplifier used is a triple stage solid-state low-noise amplifier. Class A circuitry is used in the unit to ensure excellent linearity over a very wide dynamic range. The three active devices are very moderately rated to provide a long trouble-free working life.  Its housing is an aluminium case (Iridite NCP finish) with SMA connectors for the RF input/output and a D-Type connector for the power supply and the Current Fault Alarm Function. There are no adjustments on this amplifier, and in the unlikely event of failure then the entire amplifier should be replaced.  Low Power Amplifier (12-021901) Specification  PARAMETER  SPECIFICATION Frequency range 800-960MHz* Bandwidth 20MHz * Maximum RF output >1.0 Watt Gain 15dB 1dB compression point +30.5dBm 3rd order intercept point +43dBm Noise Figure <6dB VSWR better than 1.5:1 Connectors SMA female Supply 500mA @ 10-15V DC operational -10°C to +60°C Temperature range  storage -20°C to +70°C Weight 0.5 kg Size 167x52x25mm * Tuned to Customer’s specification  Low Power Amplifier (12-021901) 7-Way Connector Pin-outs  Connector Pin  Signal A1 (large pin)  +24V DC A2 (large pin)  GND 1  Alarm relay common 2  TTL alarm/0V good 3  Alarm relay contact (bad) 4  Alarm relay contact (good) 5  O/C good/0V bad (TTL)
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 309 of 500   7.4.2.10.  Automatic Gain Control  17-001109  AGC Detector Assembly (Logarithmic) 17-001117  AGC Detector Assembly  17-001201  AGC Attenuator Assembly   The sub components 17-001109, 17-001117 & 17-001201 are parts of the Automatic Gain Control (AGC) system used in 700MHz Line Amplifier (no NPSPAC) (55-165705); 17-001117 and 17-001201 are paired for use in the uplink and 17-001109 and 17-001201 are paired for use in the downlink  700MHz Line Amplifier (no NPSPAC) (55-165705) is fitted with two differing types of Automatic Gain Control (AGC) system, one linear, and one logarithmic. The AGC with logarithmic detector (17-001117) is fitted in the uplink path and the AGC with linear detector (17-001109) is fitted in the downlink path   The AFL Automatic Gain Control system consists of two units, a detector/amplifier and an attenuator. The detector/amplifier unit is inserted in the RF path on the output of the power amplifier, and the attenuator is situated in the RF path between the 1st and 2nd stages of amplification.  17-001117 and 17-001201 are paired for use in the uplink and 17-001109 and 17-001201 are paired for use in the downlink  The attenuator comprises a 50Ω P.I.N diode, voltage-variable attenuator with a range of 3 to 30dB. The attenuation is controlled by a DC voltage which is derived from the associated detector controller board.  Normally the attenuator is at minimum attenuation. The detector/amplifier unit monitors the RF level being delivered by the power amplifier, and when a certain threshold is reached it begins to increase the value of the attenuator to limit the RF output to the (factory set) threshold. Therefore overloading of the power amplifier is avoided.  The factory set threshold is 1dB below the Enhancer 1dB compression point. Some adjustment of this AGC threshold level is possible, a 10dB range is mostly achieved. It is not recommended under any circumstances to adjust the AGC threshold to a level greater than the 1dB compression point as system degradation will occur.  The detector comprises of a 50Ω transmission line with a resistive tap which samples a small portion of the mainline power. The sampled signal is amplified and fed to a conventional half wave diode rectifier, the output of which is a DC voltage proportional to the RF input signal.  This DC voltage is passed via an inverting DC amplifier with integrating characteristics, to the output, which drives the attenuation control line of the corresponding AGC attenuator. This unit is fitted at some earlier point in the RF circuit.  For small signals, below AGC onset, the output control line will be close to 12V and the AGC attenuator will have minimum attenuation. As the signal level increases the control line voltage will fall, increasing the attenuator value and keeping the system output level at a constant value.
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 310 of 500   AGC Specification (both types)  PARAMETER  SPECIFICATION Frequency range up to 1000MHz Attenuation range 3 to 30dB  Attenuation steps continuously variable VSWR better than 1.2:1 RF Connectors SMA female attenuator 1W Power handling  detector/amp >30W (or as required) operation -10°C to +60°C Temperature range  storage -20°C to +70°C attenuator pcb 50 x 42 x 21mm Size  detector/amp pcb 54 x 42 x 21mm attenuator 90grams Weight  detector/amp 100grams   17.4.2.11. 12V (Single) Relay Board (80-008901)  The General Purpose Relay Board allows the inversion of signals and the isolation of circuits. It is equipped with a single dual pole change-over relay RL1, with completely isolated wiring, accessed via a 15 way in-line connector.  The relay is provided with polarity protection diodes and diodes for suppressing the transients caused by "flywheel effect" which can destroy switching transistors or induce spikes on neighbouring circuits. It’s common use is to amalgamate all the alarm signals into one, volts-free relay contact pair for the main alarm system.  80-008901 Specification  PARAMETER  SPECIFICATION Operating voltage 8 to 30V (floating earth) Alarm threshold Vcc - 1.20 volt +15% Alarm output relay contacts Max. switch current 1.0Amp Max. switch volts 120Vdc/60VA Max. switch power 24W/60VA Min. switch load 10.0µA/10.0mV Relay isolation 1.5kV Mechanical life >2x107 operations Relay approval BT type 56 Connector details Screw terminals operational -10°C to +60°C Temperature range  storage -20°C to +70°C
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 311 of 500   17.4.2.12. Dual Diode Assembly (94-100004)  The purpose of these dual diode assemblies is to allow two DC voltage sources to be combined, so that the main DC rail within the equipment can be sourced from either a mains driven PSU, or externally through an XLR connector or from dual mains driven PSUs . They are very heavy-duty diodes and they prevent any reverse current from flowing back to their source or the alternative supply rail. Combining diodes such as these will also be used if the equipment is to be powered from external back-up batteries.   17.4.2.13. DC/DC Converter 96-200047  96-200047 is an O.E.M. high power device with a wide input range and 12.5 amp @ 12V (150Watts) output capability used to derive a 12V fixed voltage power supply rail from a higher voltage supply, in this case 12V. In the event of failure this unit should not be repaired, only replaced.  96-200047 Specification  PARAMETER  SPECIFICATION DC Input Voltage range 19 to 36V DC Output voltage 12V ± 1% Max. current load 12.5Amps Operation -10°C to +60°C Temperature range  Storage -20°C to +85°C Working Humidity 20 to 90% RHNC     17.4.2.14. 12V Switch-Mode PSU (96-300052)  No routine maintenance of the PSU is required. If a fault is suspected, then the output voltage from the power supply may be measured on its output terminals. This is typically set to 12.2V. The adjustment potentiometer will be found close to the DC output terminals.  All the PSUs used in AFL Cell Enhancers are capable of operation from either 110 or 220V nominal AC supplies. The line voltage is sensed automatically, so no adjustment or link setting is needed by the operator.  96-300052 Specification  AC Input Supply  110 or 220V nominal Voltage 85 - 265V AC  (absolute limits) Frequency 47 to 63Hz DC Output Supply  12V DC (nominal) Voltage 10.5-13.8V (absolute limits) Current 12.5A
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 312 of 500   17.4.3. International Station Splitter (55-165710)  2U Rack mount tray   International Station Splitter (55-165710) List of major Components  Section  Component Part  Component Part Description  Qty. Per Assembly17.4.3.3.  05-002602  900MHZ SPLITTER/COMBINER, 20W  1 17.4.3.4.  05-009909  4 WAY POWER SPLITTER 70/10/10/10  1 17.4.3.5.  07-015102  Wideband Asymmetric Coupler  1
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 313 of 500   17.4.3.1. International Station Splitter (55-165710) Outline drawing Drawing number 55-1657110
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 314 of 500   17.4.3.2. International Station Splitter (55-165710) System Diagram Drawing number 55-165790
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 315 of 500    17.4.3.3. 900MHz Splitter/Combiner (05-002602)  The Splitter/Combiner used is a device for accurately matching two or more RF signals to single or multiple ports, whilst maintaining an accurate 50Ω load to all inputs/outputs and ensuring that the VSWR and insertion losses are kept to a minimum. Any unused ports should be terminated with an appropriate 50Ω load. Being passive devices, the splitters should have an extremely long operational life and require no maintenance. Should a unit be suspect, it is usually most time efficient to replace the whole module rather than attempt repair or re-tuning.  05-002602 Specification  PARAMETER  SPECIFICATION Narrowband 815 – 960MHz Frequency range  Broadband 800 – 1200MHz Narrowband 145MHz Bandwidth  Broadband 400MHz Input ports 1 Output ports 2 Narrowband 3.3dB Insertion loss  Broadband 3.5dB Return loss input & output 1.3:1 Impedance 50Ω Narrowband >20dB Isolation  Broadband >18dB MTFB >180,000 hours Splitting 20Watts Power rating  Combining 0.5Watt Connectors SMA female Weight 200g (approximately) Size 54 x 44 x 21mm      17.4.3.4.  05-009909 – BSB to provide spec ***///***
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 316 of 500   17.4.3.5. Wideband Asymmetric Coupler (07-015102)  The purpose of Wideband Asymmetric Coupler (07-015102) is to tap off a known portion (in this case 10dB) of RF signal from transmission lines and to combine them, for example through splitter units for different purposes (alarms/monitoring etc.), whilst maintaining an accurate 50Ω load to all ports/interfaces throughout the specified frequency range. They are known formally as directional couplers as they couple power from the RF mainline in one direction only.   07-015102 Specification  PARAMETER  SPECIFICATION Frequency Range 800 - 2500 MHz Coupling Value 10 dB ± 1.0 dB Main Line Insertion Loss <1.6 dB VSWR 1.4:1 Directivity >18 dB Power Rating 200 Watts RF Connectors ‘N’ female operation -20°C to +60°C Temperature range  storage -40°C to +70°C
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 317 of 500   18.   UNIVERSITY STATION CROSS PASSAGE A (80-330590-1)  Wallmount case  number C06-CR-01    University Station Cross Passage A (80-330590-1)   Section  Component Part  Component Part Description  Qty Per Assembly18.3.1.  07-015102  Wideband Asymmetric Coupler  1 18.3.2. 12-018002  Power Amplifier  2 18.3.3.  55-165701  800MHz Line Amplifier  1 18.3.4.  55-165702  700MHz Line Amplifier  1
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 318 of 500   18.1. University Station Cross Passage A (80-330590-1) System Diagram Drawing number 80-330592-1
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 319 of 500   18.2. University Station Cross Passage A (80-330590-1) Alarm Wiring Diagram Drawing Number 80-330530-1
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 320 of 500   18.3. University Station Cross Passage A (80-330590-1) Major Sub Components  18.3.1.  Wideband Asymmetric Coupler (07-015102)  The purpose of Wideband Asymmetric Coupler (07-015102) is to tap off a known portion (in this case 10dB) of RF signal from transmission lines and to combine them, for example through splitter units for different purposes (alarms/monitoring etc.), whilst maintaining an accurate 50Ω load to all ports/interfaces throughout the specified frequency range. They are known formally as directional couplers as they couple power from the RF mainline in one direction only.   07-015102 Specification  PARAMETER  SPECIFICATION Frequency Range 800 - 2500 MHz Coupling Value 10 dB ± 1.0 dB Main Line Insertion Loss <1.6 dB VSWR 1.4:1 Directivity >18 dB Power Rating 200 Watts RF Connectors ‘N’ female operation -20°C to +60°C Temperature range  storage -40°C to +70°C     18.3.2.  Power Amplifier (12-018002)  This amplifier is a Class A 20W power amplifier from 800-960MHz in a 1 stage balanced configuration. It demonstrates a very high linearity and a very good input/output return loss (RL). It has built in a Current Fault Alarm Function. Its housing is an aluminium case (Iridite NCP finish) with SMA connectors for the RF input/output and a D-Type connector for the power supply and the Current Fault Alarm Function.  12-018002 Specification  PARAMETER  SPECIFICATION Frequency range 800-960MHz Small signal gain 30dB Gain flatness ±1.2dB I/O Return loss >18dB 1dB compression point 42.8dBm OIP3 56dBm Supply voltage 24V DC Supply current 5.0Amps (Typical) operational -10°C to +60°C Temperature range  storage -20°C to +70°C Weight <2kg (no heatsink)
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 321 of 500   Power Amplifier (12-018002) 7-Way Connector Pin-outs  Connector Pin  Signal A1 (large pin)  +24V DC A2 (large pin)  GND 1  Alarm relay common 2  TTL alarm/0V good 3  Alarm relay contact (bad) 4  Alarm relay contact (good) 5  O/C good/0V bad (TTL)
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 322 of 500   18.3.3.  800MHz Line Amplifier (55-165701)  5U rack mount case   800MHz Line Amplifier (55-165701) List of Major Components  Section  Component Part  Component Part Description  Qty Per Assembly18.3.3.3. 02-007206 Bandpass Filter  4 18.3.3.4.  07-015105  Wideband Asymmetric Coupler  1 18.3.3.5.  10-000901  Switched Attenuator 0.25W, 0 - 15dB  2 18.3.3.6.  11-006702  Low Noise Amplifier  1 18.3.3.7.  12-021901  Low Power Amplifier  2 17-001109*  AGC Detector Assembly (Logarithmic)  1 17-001117*  AGC Detector Assembly  1 18.3.3.8. 17-001201*  AGC Attenuator Assembly  2 18.3.3.9.  80-008901  12V (Single) Relay Board  1 18.3.3.10.  94-100004  Dual Diode Assembly  1 18.3.3.11. 96-200047 DC/DC Converter  1 18.3.3.12.  96-300052  12V Switch-Mode PSU  1   *The sub components 17-001109, 17-001117 & 17-001201 are parts of the Automatic Gain Control (AGC) system used in 800MHz Line Amplifier (55-165701); 17-001117 and 17-001201 are paired for use in the uplink and 17-001109 and 17-001201 are paired for use in the down link
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 323 of 500   18.3.3.1.  800MHz Line Amplifier (55-165701) Outline Drawing  Drawing number 55-1657101
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 324 of 500   18.3.3.2.  800MHz Line Amplifier (55-165701) System Diagram  Drawing number 55-165781
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 325 of 500   18.3.3.3.  Bandpass Filter (02-007206)  The bandpass filters are multi-section designs with a bandwidth dependent upon the passband frequencies, (both tuned to customer requirements). The response shape is basically Chebyshev with a passband design ripple of 0.1dB. The filters are of slot coupled, folded combline design, and are carefully aligned during manufacture in order to optimise the insertion loss, VSWR and intermodulation characteristics of the unit. The tuned elements are silver-plated to reduce surface ohmic losses and maintain a good VSWR figure and 50Ω load at the input and output ports.  Being passive devices, the bandpass filters should have an extremely long operational life and require no maintenance. Should a filter be suspect, it is usually most time efficient to replace the module rather than attempt repair or re-tuning.  No adjustments should be attempted without full network sweep analysis facilities to monitor both insertion loss and VSWR simultaneously.  02-007206 Specification  PARAMETER  SPECIFICATION Response type Chebyshev Frequency range 800 - 950MHz * Bandwidth 25MHz * Number of sections 8 Insertion loss 1.2 dB VSWR better than 1.2:1 Connectors SMA female Power handling 100W max operation -20°C to +60°C Temperature range  storage -40°C to +70°C Weight 3 kg (typical)  *tuned to Customer's specification    18.3.3.4. Wideband Asymmetric Coupler (07-015105)  The purpose of Wideband Asymmetric Coupler (07-015105) is to tap off a known portion (in this case 30dB) of RF signal from transmission lines and to combine them, for example through splitter units for different purposes (alarms/monitoring etc.), whilst maintaining an accurate 50Ω load to all ports/interfaces throughout the specified frequency range. They are known formally as directional couplers as they couple power from the RF mainline in one direction only.   07-015105 Specification  PARAMETER  SPECIFICATION Construction Inductive air gap Frequency 800-2500MHz Through loss 0.4dB (typical) Coupling level -30dB ±0.5dB Isolation N/A Weight <1.0kg Connectors SMA, female operation -20°C to +60°C Temperature range  storage -40°C to +70°C
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 326 of 500   18.3.3.5. Switched Attenuator 0.25W, 0 - 15dB (10-000901)  In many practical applications for Cell Enhancers etc., the gain in each path is found to be excessive. Therefore, provision is made within the unit for the setting of attenuation in each path, to reduce the gain.  10-000901 provides attenuation from 0 - 15dB in 2 dB steps The attenuation is simply set using the four miniature toggle switches on the top of each unit. Each switch is clearly marked with the attenuation it provides, and the total attenuation in line is the sum of the values switched in. They are designed to maintain an accurate 50Ω impedance over their operating frequency at both input and output.  10-000901 Specification  PARAMETER  SPECIFICATION Attenuation Values 0-15dB Attenuation Steps 1, 2, 4 and 8dB Power Handling 0.25 Watt Attenuation Accuracy ± 1.0 dB Frequency Range DC to 1GHz Impedance 50Ω Connectors SMA VSWR 1.3:1 Weigh 0.2kg operation -20°C to +60°C Temperature range  storage -40°C to +70°C   18.3.3.6.  Low Noise Amplifier (11-006702)  The Gallium-Arsenide low noise amplifiers used in 800MHz Line Amplifier (55-165703) are double stage, solid-state low noise amplifiers. Class A circuitry is used throughout the units to ensure excellent linearity and extremely low noise over a very wide dynamic range. The active devices are very moderately rated to provide a long trouble-free working life. There are no adjustments on these amplifiers, and in the unlikely event of a failure, then the complete amplifier should be replaced. This amplifier features its own in-built alarm system which gives a volt-free relay contact type alarm that is easily integrated into the main alarm system.  11-006702 Specification  PARAMETER  SPECIFICATION Frequency range 800 – 1000MHz Bandwidth <200MHz Gain 29dB (typical) 1dB Compression point 20dBm OIP3 33dBm Input/Output return loss >18dB Noise figure 1.3dB (typical) Power consumption 180mA @ 24V DC Supply voltage 10-24V DC Connectors SMA female operational -10°C to +60°C Temperature range:  storage -20°C to +70°C Size 90 x 55 x 30.2mm Weight 290gms (approximately)
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 327 of 500  7 8 961 2 3 4 59-Way Pin-Out Graphical Representation Low Noise Amplifier (11-006702) ‘D’ Connector Pin-out details  Connector pin  Signal 1  +Ve input (10-24V) 2 GND 3  Alarm RelayO/P bad 4  Alarm Relay common 5  Alarm Relay good 6 No connection 7  TTL voltage set 8  TTL alarm/0V (good) 9  O/C good/0V bad                18.3.3.7.  Low Power Amplifier (12-021901)  The low power amplifier used is a triple stage solid-state low-noise amplifier. Class A circuitry is used in the unit to ensure excellent linearity over a very wide dynamic range. The three active devices are very moderately rated to provide a long trouble-free working life.  Its housing is an aluminium case (Iridite NCP finish) with SMA connectors for the RF input/output and a D-Type connector for the power supply and the Current Fault Alarm Function. There are no adjustments on this amplifier, and in the unlikely event of failure then the entire amplifier should be replaced.  Low Power Amplifier (12-021901) Specification  PARAMETER  SPECIFICATION Frequency range 800-960MHz* Bandwidth 20MHz * Maximum RF output >1.0 Watt Gain 15dB 1dB compression point +30.5dBm 3rd order intercept point +43dBm Noise Figure <6dB VSWR better than 1.5:1 Connectors SMA female Supply 500mA @ 10-15V DC operational -10°C to +60°C Temperature range  storage -20°C to +70°C Weight 0.5 kg Size 167x52x25mm * Tuned to Customer’s specification
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 328 of 500   Low Power Amplifier (12-021901) 7-Way Connector Pin-outs  Connector Pin  Signal A1 (large pin)  +24V DC A2 (large pin)  GND 1  Alarm relay common 2  TTL alarm/0V good 3  Alarm relay contact (bad) 4  Alarm relay contact (good) 5  O/C good/0V bad (TTL)                      18.3.3.8.  Automatic Gain Control  17-001109  AGC Detector Assembly (Logarithmic) 17-001117  AGC Detector Assembly  17-001201  AGC Attenuator Assembly   The sub components 17-001109, 17-001117 & 17-001201 are parts of the Automatic Gain Control (AGC) system used in 800MHz Line Amplifier (55-165701); 17-001117 and 17-001201 are paired for use in the uplink and 17-001109 and 17-001201 are paired for use in the downlink  800MHz Line Amplifier (55-165701) is fitted with two differing types of Automatic Gain Control (AGC) system, one linear, and one logarithmic. The AGC with logarithmic detector (17-001117) is fitted in the uplink path and the AGC with linear detector (17-001109) is fitted in the downlink path   The AFL Automatic Gain Control system consists of two units, a detector/amplifier and an attenuator. The detector/amplifier unit is inserted in the RF path on the output of the power amplifier, and the attenuator is situated in the RF path between the 1st and 2nd stages of amplification.  17-001117 and 17-001201 are paired for use in the uplink and 17-001109 and 17-001201 are paired for use in the downlink  The attenuator comprises a 50Ω P.I.N diode, voltage-variable attenuator with a range of 3 to 30dB. The attenuation is controlled by a DC voltage which is derived from the associated detector controller board.
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 329 of 500   Normally the attenuator is at minimum attenuation. The detector/amplifier unit monitors the RF level being delivered by the power amplifier, and when a certain threshold is reached it begins to increase the value of the attenuator to limit the RF output to the (factory set) threshold. Therefore overloading of the power amplifier is avoided.  The factory set threshold is 1dB below the Enhancer 1dB compression point. Some adjustment of this AGC threshold level is possible, a 10dB range is mostly achieved. It is not recommended under any circumstances to adjust the AGC threshold to a level greater than the 1dB compression point as system degradation will occur.  The detector comprises of a 50Ω transmission line with a resistive tap which samples a small portion of the mainline power. The sampled signal is amplified and fed to a conventional half wave diode rectifier, the output of which is a DC voltage proportional to the RF input signal.  This DC voltage is passed via an inverting DC amplifier with integrating characteristics, to the output, which drives the attenuation control line of the corresponding AGC attenuator. This unit is fitted at some earlier point in the RF circuit.  For small signals, below AGC onset, the output control line will be close to 12V and the AGC attenuator will have minimum attenuation. As the signal level increases the control line voltage will fall, increasing the attenuator value and keeping the system output level at a constant value.  AGC Specification (both types)  PARAMETER  SPECIFICATION Frequency range up to 1000MHz Attenuation range 3 to 30dB  Attenuation steps continuously variable VSWR better than 1.2:1 RF Connectors SMA female attenuator 1W Power handling  detector/amp >30W (or as required) operation -10°C to +60°C Temperature range  storage -20°C to +70°C attenuator pcb 50 x 42 x 21mm Size  detector/amp pcb 54 x 42 x 21mm attenuator 90grams Weight  detector/amp 100grams   18.3.3.9. 12V (Single) Relay Board (80-008901)  The General Purpose Relay Board allows the inversion of signals and the isolation of circuits. It is equipped with a single dual pole change-over relay RL1, with completely isolated wiring, accessed via a 15 way in-line connector.  The relay is provided with polarity protection diodes and diodes for suppressing the transients caused by "flywheel effect" which can destroy switching transistors or induce spikes on neighbouring circuits. It’s common use is to amalgamate all the alarm signals into one, volts-free relay contact pair for the main alarm system.
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 330 of 500   80-008901 Specification  PARAMETER  SPECIFICATION Operating voltage 8 to 30V (floating earth) Alarm threshold Vcc - 1.20 volt +15% Alarm output relay contacts Max. switch current 1.0Amp Max. switch volts 120Vdc/60VA Max. switch power 24W/60VA Min. switch load 10.0µA/10.0mV Relay isolation 1.5kV Mechanical life >2x107 operations Relay approval BT type 56 Connector details Screw terminals operational -10°C to +60°C Temperature range  storage -20°C to +70°C      18.3.3.10. Dual Diode Assembly (94-100004)  The purpose of these dual diode assemblies is to allow two DC voltage sources to be combined, so that the main DC rail within the equipment can be sourced from either a mains driven PSU, or externally through an XLR connector or from dual mains driven PSUs. They are very heavy-duty diodes and they prevent any reverse current from flowing back to their source or the alternative supply rail. Combining diodes such as these will also be used if the equipment is to be powered from external back-up batteries.       18.3.3.11. DC/DC Converter 96-200047  96-200047 is an O.E.M. high power device with a wide input range and 12.5 amp @ 12V (150Watts) output capability used to derive a 12V fixed voltage power supply rail from a higher voltage supply, in this case 12V. In the event of failure this unit should not be repaired, only replaced.  96-200047 Specification  PARAMETER  SPECIFICATION DC Input Voltage range 19 to 36V DC Output voltage 12V ± 1% Max. current load 12.5Amps Operation -10°C to +60°C Temperature range  Storage -20°C to +85°C Working Humidity 20 to 90% RHNC
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 331 of 500   18.3.3.12. 12V Switch-Mode PSU (96-300052)  No routine maintenance of the PSU is required. If a fault is suspected, then the output voltage from the power supply may be measured on its output terminals. This is typically set to 12.2V. The adjustment potentiometer will be found close to the DC output terminals.  All the PSUs used in AFL Cell Enhancers are capable of operation from either 110 or 220V nominal AC supplies. The line voltage is sensed automatically, so no adjustment or link setting is needed by the operator.  96-300052 Specification  AC Input Supply  110 or 220V nominal Voltage 85 - 265V AC  (absolute limits) Frequency 47 to 63Hz DC Output Supply  12V DC (nominal) Voltage 10.5-13.8V (absolute limits) Current 12.5A
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 332 of 500   18.3.4.  700MHz Line Amplifier (55-165702)  5U rack mount case   700MHz Line Amplifier (55-165702) List of Major Components  Section  Component Part  Component Part Description  Qty Per Assembly18.3.4.3. 02-007206 Bandpass Filter  4 18.3.4.4.  07-015105  Wideband Asymmetric Coupler  1 18.3.4.5.  10-000901  Switched Attenuator 0.25W, 0 - 15dB  2 18.3.4.6.  11-006702  Low Noise Amplifier  1 18.3.4.7.  12-021901  Low Power Amplifier  2 17-001109*  AGC Detector Assembly (Logarithmic)  1 17-001117*  AGC Detector Assembly  1 18.3.4.8. 17-001201*  AGC Attenuator Assembly  2 18.3.4.9.  80-008901  12V (Single) Relay Board  1 18.3.4.0.  94-100004  Dual Diode Assembly  1 18.3.4.11. 96-200047  DC/DC Converter   18.3.4.12.  96-300052  12V Switch-Mode PSU  1   *The sub components 17-001109, 17-001117 & 17-001201 are parts of the Automatic Gain Control (AGC) system used in 700MHz Line Amplifier (55-165702); 17-001117 and 17-001201 are paired for use in the uplink and 17-001109 and 17-001201 are paired for use in the down link
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 333 of 500   18.3.4.1.  700MHz Line Amplifier (55-165702) Outline Drawing  Drawing Number 55-1657102
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 334 of 500   18.3.4.2.  700MHz Line Amplifier (55-165702) System Diagram  Drawing Number 55-165782
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 335 of 500   18.3.4.3.  Bandpass Filter (02-007206)  The bandpass filters are multi-section designs with a bandwidth dependent upon the passband frequencies, (both tuned to customer requirements). The response shape is basically Chebyshev with a passband design ripple of 0.1dB. The filters are of slot coupled, folded combline design, and are carefully aligned during manufacture in order to optimise the insertion loss, VSWR and intermodulation characteristics of the unit. The tuned elements are silver-plated to reduce surface ohmic losses and maintain a good VSWR figure and 50Ω load at the input and output ports.  Being passive devices, the bandpass filters should have an extremely long operational life and require no maintenance. Should a filter be suspect, it is usually most time efficient to replace the module rather than attempt repair or re-tuning.  No adjustments should be attempted without full network sweep analysis facilities to monitor both insertion loss and VSWR simultaneously.  02-007206 Specification  PARAMETER  SPECIFICATION Response type Chebyshev Frequency range 800 - 950MHz * Bandwidth 25MHz * Number of sections 8 Insertion loss 1.2 dB VSWR better than 1.2:1 Connectors SMA female Power handling 100W max operation -20°C to +60°C Temperature range  storage -40°C to +70°C Weight 3 kg (typical)  *tuned to Customer's specification    18.3.4.4. Wideband Asymmetric Coupler (07-015105)  The purpose of Wideband Asymmetric Coupler (07-015105) is to tap off a known portion (in this case 30dB) of RF signal from transmission lines and to combine them, for example through splitter units for different purposes (alarms/monitoring etc.), whilst maintaining an accurate 50Ω load to all ports/interfaces throughout the specified frequency range. They are known formally as directional couplers as they couple power from the RF mainline in one direction only.   07-015105 Specification  PARAMETER  SPECIFICATION Construction Inductive air gap Frequency 800-2500MHz Through loss 0.4dB (typical) Coupling level -30dB ±0.5dB Isolation N/A Weight <1.0kg Connectors SMA, female operation -20°C to +60°C Temperature range  storage -40°C to +70°C
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 336 of 500   18.3.4.5. Switched Attenuator 0.25W, 0 - 15dB (10-000901)  In many practical applications for Cell Enhancers etc., the gain in each path is found to be excessive. Therefore, provision is made within the unit for the setting of attenuation in each path, to reduce the gain. 10-000901 provides attenuation from 0 - 15dB in 2 dB steps The attenuation is simply set using the four miniature toggle switches on the top of each unit. Each switch is clearly marked with the attenuation it provides, and the total attenuation in line is the sum of the values switched in. They are designed to maintain an accurate 50Ω impedance over their operating frequency at both input and output.  10-000901 Specification  PARAMETER  SPECIFICATION Attenuation Values 0-15dB Attenuation Steps 1, 2, 4 and 8dB Power Handling 0.25 Watt Attenuation Accuracy ± 1.0 dB Frequency Range DC to 1GHz Impedance 50Ω Connectors SMA VSWR 1.3:1 Weigh 0.2kg operation -20°C to +60°C Temperature range  storage -40°C to +70°C    18.3.4.6.  Low Noise Amplifier (11-006702)  The Gallium-Arsenide low noise amplifiers used in 800MHz Line Amplifier (55-165703) are double stage, solid-state low noise amplifiers. Class A circuitry is used throughout the units to ensure excellent linearity and extremely low noise over a very wide dynamic range. The active devices are very moderately rated to provide a long trouble-free working life. There are no adjustments on these amplifiers, and in the unlikely event of a failure, then the complete amplifier should be replaced. This amplifier features its own in-built alarm system which gives a volt-free relay contact type alarm that is easily integrated into the main alarm system.  11-006702 Specification  PARAMETER  SPECIFICATION Frequency range 800 – 1000MHz Bandwidth <200MHz Gain 29dB (typical) 1dB Compression point 20dBm OIP3 33dBm Input/Output return loss >18dB Noise figure 1.3dB (typical) Power consumption 180mA @ 24V DC Supply voltage 10-24V DC Connectors SMA female operational -10°C to +60°C Temperature range:  storage -20°C to +70°C Size 90 x 55 x 30.2mm Weight 290gms (approximately)
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 337 of 500  7 8 961 2 3 4 59-Way Pin-Out Graphical Representation Low Noise Amplifier (11-006702) ‘D’ Connector Pin-out details  Connector pin  Signal 1  +Ve input (10-24V) 2 GND 3  Alarm RelayO/P bad 4  Alarm Relay common 5  Alarm Relay good 6 No connection 7  TTL voltage set 8  TTL alarm/0V (good) 9  O/C good/0V bad               18.3.4.7.  Low Power Amplifier (12-021901)  The low power amplifier used is a triple stage solid-state low-noise amplifier. Class A circuitry is used in the unit to ensure excellent linearity over a very wide dynamic range. The three active devices are very moderately rated to provide a long trouble-free working life.  Its housing is an aluminium case (Iridite NCP finish) with SMA connectors for the RF input/output and a D-Type connector for the power supply and the Current Fault Alarm Function. There are no adjustments on this amplifier, and in the unlikely event of failure then the entire amplifier should be replaced.  Low Power Amplifier (12-021901) Specification  PARAMETER  SPECIFICATION Frequency range 800-960MHz* Bandwidth 20MHz * Maximum RF output >1.0 Watt Gain 15dB 1dB compression point +30.5dBm 3rd order intercept point +43dBm Noise Figure <6dB VSWR better than 1.5:1 Connectors SMA female Supply 500mA @ 10-15V DC operational -10°C to +60°C Temperature range  storage -20°C to +70°C Weight 0.5 kg Size 167x52x25mm * Tuned to Customer’s specification
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 338 of 500   Low Power Amplifier (12-021901) 7-Way Connector Pin-outs  Connector Pin  Signal A1 (large pin)  +24V DC A2 (large pin)  GND 1  Alarm relay common 2  TTL alarm/0V good 3  Alarm relay contact (bad) 4  Alarm relay contact (good) 5  O/C good/0V bad (TTL)                 18.3.4.8.  Automatic Gain Control  17-001109  AGC Detector Assembly (Logarithmic) 17-001117  AGC Detector Assembly  17-001201  AGC Attenuator Assembly   The sub components 17-001109, 17-001117 & 17-001201 are parts of the Automatic Gain Control (AGC) system used in 700MHz Line Amplifier (55-165702); 17-001117 and 17-001201 are paired for use in the uplink and 17-001109 and 17-001201 are paired for use in the downlink  700MHz Line Amplifier (55-165702) is fitted with two differing types of Automatic Gain Control (AGC) system, one linear, and one logarithmic. The AGC with logarithmic detector (17-001117) is fitted in the uplink path and the AGC with linear detector (17-001109) is fitted in the downlink path   The AFL Automatic Gain Control system consists of two units, a detector/amplifier and an attenuator. The detector/amplifier unit is inserted in the RF path on the output of the power amplifier, and the attenuator is situated in the RF path between the 1st and 2nd stages of amplification.  17-001117 and 17-001201 are paired for use in the uplink and 17-001109 and 17-001201 are paired for use in the downlink  The attenuator comprises a 50Ω P.I.N diode, voltage-variable attenuator with a range of 3 to 30dB. The attenuation is controlled by a DC voltage which is derived from the associated detector controller board.
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 339 of 500   Normally the attenuator is at minimum attenuation. The detector/amplifier unit monitors the RF level being delivered by the power amplifier, and when a certain threshold is reached it begins to increase the value of the attenuator to limit the RF output to the (factory set) threshold. Therefore overloading of the power amplifier is avoided.  The factory set threshold is 1dB below the Enhancer 1dB compression point. Some adjustment of this AGC threshold level is possible, a 10dB range is mostly achieved. It is not recommended under any circumstances to adjust the AGC threshold to a level greater than the 1dB compression point as system degradation will occur.  The detector comprises of a 50Ω transmission line with a resistive tap which samples a small portion of the mainline power. The sampled signal is amplified and fed to a conventional half wave diode rectifier, the output of which is a DC voltage proportional to the RF input signal.  This DC voltage is passed via an inverting DC amplifier with integrating characteristics, to the output, which drives the attenuation control line of the corresponding AGC attenuator. This unit is fitted at some earlier point in the RF circuit.  For small signals, below AGC onset, the output control line will be close to 12V and the AGC attenuator will have minimum attenuation. As the signal level increases the control line voltage will fall, increasing the attenuator value and keeping the system output level at a constant value.  AGC Specification (both types)  PARAMETER  SPECIFICATION Frequency range up to 1000MHz Attenuation range 3 to 30dB  Attenuation steps continuously variable VSWR better than 1.2:1 RF Connectors SMA female attenuator 1W Power handling  detector/amp >30W (or as required) operation -10°C to +60°C Temperature range  storage -20°C to +70°C attenuator pcb 50 x 42 x 21mm Size  detector/amp pcb 54 x 42 x 21mm attenuator 90grams Weight  detector/amp 100grams     18.3.4.9. 12V (Single) Relay Board (80-008901)  The General Purpose Relay Board allows the inversion of signals and the isolation of circuits. It is equipped with a single dual pole change-over relay RL1, with completely isolated wiring, accessed via a 15 way in-line connector.  The relay is provided with polarity protection diodes and diodes for suppressing the transients caused by "flywheel effect" which can destroy switching transistors or induce spikes on neighbouring circuits. It’s common use is to amalgamate all the alarm signals into one, volts-free relay contact pair for the main alarm system.
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 340 of 500   80-008901 Specification  PARAMETER  SPECIFICATION Operating voltage 8 to 30V (floating earth) Alarm threshold Vcc - 1.20 volt +15% Alarm output relay contacts Max. switch current 1.0Amp Max. switch volts 120Vdc/60VA Max. switch power 24W/60VA Min. switch load 10.0µA/10.0mV Relay isolation 1.5kV Mechanical life >2x107 operations Relay approval BT type 56 Connector details Screw terminals operational -10°C to +60°C Temperature range  storage -20°C to +70°C     18.3.4.10. Dual Diode Assembly (94-100004)  The purpose of these dual diode assemblies is to allow two DC voltage sources to be combined, so that the main DC rail within the equipment can be sourced from either a mains driven PSU, or externally through an XLR connector or from dual mains driven PSUs. They are very heavy-duty diodes and they prevent any reverse current from flowing back to their source or the alternative supply rail. Combining diodes such as these will also be used if the equipment is to be powered from external back-up batteries.    18.3.4.11. DC/DC Converter 96-200047  96-200047 is an O.E.M. high power device with a wide input range and 12.5 amp @ 12V (150Watts) output capability used to derive a 12V fixed voltage power supply rail from a higher voltage supply, in this case 12V. In the event of failure this unit should not be repaired, only replaced.  96-200047 Specification  PARAMETER  SPECIFICATION DC Input Voltage range 19 to 36V DC Output voltage 12V ± 1% Max. current load 12.5Amps Operation -10°C to +60°C Temperature range  Storage -20°C to +85°C Working Humidity 20 to 90% RHNC
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 341 of 500   18.3.4.12. 12V Switch-Mode PSU (96-300052)  No routine maintenance of the PSU is required. If a fault is suspected, then the output voltage from the power supply may be measured on its output terminals. This is typically set to 12.2V. The adjustment potentiometer will be found close to the DC output terminals.  All the PSUs used in AFL Cell Enhancers are capable of operation from either 110 or 220V nominal AC supplies. The line voltage is sensed automatically, so no adjustment or link setting is needed by the operator.  96-300052 Specification  AC Input Supply  110 or 220V nominal Voltage 85 - 265V AC  (absolute limits) Frequency 47 to 63Hz DC Output Supply  12V DC (nominal) Voltage 10.5-13.8V (absolute limits) Current 12.5A
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 342 of 500   19.   UNIVERSITY STATION CROSS PASSAGE B (80-330590-2)  Wallmount case  number C06-CR-02    University Station Cross Passage B (80-330590-2)   Section  Component Part  Component Part Description  Qty Per Assembly 19.3.1.  07-015102  Wideband Asymmetric Coupler  1 19.3.2. 12-018002  Power Amplifier  2 19.3.3.  55-165701  800MHz Line Amplifier  1 19.3.4.  55-165702  700MHz Line Amplifier  1
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 343 of 500   19.1. University Station Cross Passage B (80-330590-2) System Diagram Drawing number 80-330592-2
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 344 of 500   19.2. University Station Cross Passage B (80-330590-2) Alarm Wiring Diagram  Drawing Number 80-330530-2
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 345 of 500   19.3. University Station Cross Passage B (80-330590-2) Major Sub Components  19.3.1.  Wideband Asymmetric Coupler (07-015102)  The purpose of Wideband Asymmetric Coupler (07-015102) is to tap off a known portion (in this case 10dB) of RF signal from transmission lines and to combine them, for example through splitter units for different purposes (alarms/monitoring etc.), whilst maintaining an accurate 50Ω load to all ports/interfaces throughout the specified frequency range. They are known formally as directional couplers as they couple power from the RF mainline in one direction only.   07-015102 Specification  PARAMETER  SPECIFICATION Frequency Range 800 - 2500 MHz Coupling Value 10 dB ± 1.0 dB Main Line Insertion Loss <1.6 dB VSWR 1.4:1 Directivity >18 dB Power Rating 200 Watts RF Connectors ‘N’ female operation -20°C to +60°C Temperature range  storage -40°C to +70°C     19.3.2.  Power Amplifier (12-018002)  This amplifier is a Class A 20W power amplifier from 800-960MHz in a 1 stage balanced configuration. It demonstrates a very high linearity and a very good input/output return loss (RL). It has built in a Current Fault Alarm Function. Its housing is an aluminium case (Iridite NCP finish) with SMA connectors for the RF input/output and a D-Type connector for the power supply and the Current Fault Alarm Function.  12-018002 Specification  PARAMETER  SPECIFICATION Frequency range 800-960MHz Small signal gain 30dB Gain flatness ±1.2dB I/O Return loss >18dB 1dB compression point 42.8dBm OIP3 56dBm Supply voltage 24V DC Supply current 5.0Amps (Typical) operational -10°C to +60°C Temperature range  storage -20°C to +70°C Weight <2kg (no heatsink)
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 346 of 500   Power Amplifier (12-018002) 7-Way Connector Pin-outs  Connector Pin  Signal A1 (large pin)  +24V DC A2 (large pin)  GND 1  Alarm relay common 2  TTL alarm/0V good 3  Alarm relay contact (bad) 4  Alarm relay contact (good) 5  O/C good/0V bad (TTL)
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 347 of 500   19.3.3.  800MHz Line Amplifier (55-165701)  5U rack mount case   800MHz Line Amplifier (55-165701) List of Major Components  Section  Component Part  Component Part Description  Qty Per Assembly19.3.3.3. 02-007206  Bandpass Filter  4 19.3.3.4.  07-015105  Wideband Asymmetric Coupler  1 19.3.3.5.  10-000901  Switched Attenuator 0.25W, 0 - 15dB  2 19.3.3.6.  11-006702  Low Noise Amplifier  1 19.3.3.7.  12-021901  Low Power Amplifier  2 17-001109  AGC Detector Assembly (Logarithmic)  1 17-001117  AGC Detector Assembly  1 19.3.3.8. 17-001201  AGC Attenuator Assembly  2 19.3.3.9.  80-008901  12V (Single) Relay Board  1 19.3.3.10.  94-100004  Dual Diode Assembly  1 19.3.3.11. 96-200047  DC/DC Converter  1 19.3.3.12.  96-300052  12V Switch-Mode PSU  1  *The sub components 17-001109, 17-001117 & 17-001201 are parts of the Automatic Gain Control (AGC) system used in 800MHz Line Amplifier (55-165701); 17-001117 and 17-001201 are paired for use in the uplink and 17-001109 and 17-001201 are paired for use in the down link
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 348 of 500   19.3.3.1.  800MHz Line Amplifier (55-165701) Outline Drawing  Drawing number 55-1657101
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 349 of 500   19.3.3.2.  800MHz Line Amplifier (55-165701) System Diagram  Drawing number 55-165781
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 350 of 500   19.3.3.3.  Bandpass Filter (02-007206)  The bandpass filters are multi-section designs with a bandwidth dependent upon the passband frequencies, (both tuned to customer requirements). The response shape is basically Chebyshev with a passband design ripple of 0.1dB. The filters are of slot coupled, folded combline design, and are carefully aligned during manufacture in order to optimise the insertion loss, VSWR and intermodulation characteristics of the unit. The tuned elements are silver-plated to reduce surface ohmic losses and maintain a good VSWR figure and 50Ω load at the input and output ports.  Being passive devices, the bandpass filters should have an extremely long operational life and require no maintenance. Should a filter be suspect, it is usually most time efficient to replace the module rather than attempt repair or re-tuning.  No adjustments should be attempted without full network sweep analysis facilities to monitor both insertion loss and VSWR simultaneously.  02-007206 Specification  PARAMETER  SPECIFICATION Response type Chebyshev Frequency range 800 - 950MHz * Bandwidth 25MHz * Number of sections 8 Insertion loss 1.2 dB VSWR better than 1.2:1 Connectors SMA female Power handling 100W max operation -20°C to +60°C Temperature range  storage -40°C to +70°C Weight 3 kg (typical)  *tuned to Customer's specification   19.3.3.4. Wideband Asymmetric Coupler (07-015105)  The purpose of Wideband Asymmetric Coupler (07-015105) is to tap off a known portion (in this case 30dB) of RF signal from transmission lines and to combine them, for example through splitter units for different purposes (alarms/monitoring etc.), whilst maintaining an accurate 50Ω load to all ports/interfaces throughout the specified frequency range. They are known formally as directional couplers as they couple power from the RF mainline in one direction only.   07-015105 Specification  PARAMETER  SPECIFICATION Construction Inductive air gap Frequency 800-2500MHz Through loss 0.4dB (typical) Coupling level -30dB ±0.5dB Isolation N/A Weight <1.0kg Connectors SMA, female operation -20°C to +60°C Temperature range  storage -40°C to +70°C
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 351 of 500   19.3.3.5. Switched Attenuator 0.25W, 0 - 15dB (10-000901)  In many practical applications for Cell Enhancers etc., the gain in each path is found to be excessive. Therefore, provision is made within the unit for the setting of attenuation in each path, to reduce the gain.  10-000901 provides attenuation from 0 - 15dB in 2 dB steps The attenuation is simply set using the four miniature toggle switches on the top of each unit. Each switch is clearly marked with the attenuation it provides, and the total attenuation in line is the sum of the values switched in. They are designed to maintain an accurate 50Ω impedance over their operating frequency at both input and output.  10-000901 Specification  PARAMETER  SPECIFICATION Attenuation Values 0-15dB Attenuation Steps 1, 2, 4 and 8dB Power Handling 0.25 Watt Attenuation Accuracy ± 1.0 dB Frequency Range DC to 1GHz Impedance 50Ω Connectors SMA VSWR 1.3:1 Weigh 0.2kg operation -20°C to +60°C Temperature range  storage -40°C to +70°C   19.3.3.6.  Low Noise Amplifier (11-006702)  The Gallium-Arsenide low noise amplifiers used in 800MHz Line Amplifier (55-165703) are double stage, solid-state low noise amplifiers. Class A circuitry is used throughout the units to ensure excellent linearity and extremely low noise over a very wide dynamic range. The active devices are very moderately rated to provide a long trouble-free working life. There are no adjustments on these amplifiers, and in the unlikely event of a failure, then the complete amplifier should be replaced. This amplifier features its own in-built alarm system which gives a volt-free relay contact type alarm that is easily integrated into the main alarm system.  11-006702 Specification  PARAMETER  SPECIFICATION Frequency range 800 – 1000MHz Bandwidth <200MHz Gain 29dB (typical) 1dB Compression point 20dBm OIP3 33dBm Input/Output return loss >18dB Noise figure 1.3dB (typical) Power consumption 180mA @ 24V DC Supply voltage 10-24V DC Connectors SMA female operational -10°C to +60°C Temperature range:  storage -20°C to +70°C Size 90 x 55 x 30.2mm Weight 290gms (approximately)
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 352 of 500  7 8 961 2 3 4 59-Way Pin-Out Graphical Representation Low Noise Amplifier (11-006702) ‘D’ Connector Pin-out details  Connector pin  Signal 1  +Ve input (10-24V) 2 GND 3  Alarm RelayO/P bad 4  Alarm Relay common 5  Alarm Relay good 6 No connection 7  TTL voltage set 8  TTL alarm/0V (good) 9  O/C good/0V bad                19.3.3.7.  Low Power Amplifier (12-021901)  The low power amplifier used is a triple stage solid-state low-noise amplifier. Class A circuitry is used in the unit to ensure excellent linearity over a very wide dynamic range. The three active devices are very moderately rated to provide a long trouble-free working life.  Its housing is an aluminium case (Iridite NCP finish) with SMA connectors for the RF input/output and a D-Type connector for the power supply and the Current Fault Alarm Function. There are no adjustments on this amplifier, and in the unlikely event of failure then the entire amplifier should be replaced.  Low Power Amplifier (12-021901) Specification  PARAMETER  SPECIFICATION Frequency range 800-960MHz* Bandwidth 20MHz * Maximum RF output >1.0 Watt Gain 15dB 1dB compression point +30.5dBm 3rd order intercept point +43dBm Noise Figure <6dB VSWR better than 1.5:1 Connectors SMA female Supply 500mA @ 10-15V DC operational -10°C to +60°C Temperature range  storage -20°C to +70°C Weight 0.5 kg Size 167x52x25mm * Tuned to Customer’s specification
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 353 of 500   Low Power Amplifier (12-021901) 7-Way Connector Pin-outs  Connector Pin  Signal A1 (large pin)  +24V DC A2 (large pin)  GND 1  Alarm relay common 2  TTL alarm/0V good 3  Alarm relay contact (bad) 4  Alarm relay contact (good) 5  O/C good/0V bad (TTL)                     19.3.3.8.  Automatic Gain Control  17-001109  AGC Detector Assembly (Logarithmic) 17-001117  AGC Detector Assembly  17-001201  AGC Attenuator Assembly   The sub components 17-001109, 17-001117 & 17-001201 are parts of the Automatic Gain Control (AGC) system used in 800MHz Line Amplifier (55-165701); 17-001117 and 17-001201 are paired for use in the uplink and 17-001109 and 17-001201 are paired for use in the downlink  800MHz Line Amplifier (55-165701) is fitted with two differing types of Automatic Gain Control (AGC) system, one linear, and one logarithmic. The AGC with logarithmic detector (17-001117) is fitted in the uplink path and the AGC with linear detector (17-001109) is fitted in the downlink path   The AFL Automatic Gain Control system consists of two units, a detector/amplifier and an attenuator. The detector/amplifier unit is inserted in the RF path on the output of the power amplifier, and the attenuator is situated in the RF path between the 1st and 2nd stages of amplification.  17-001117 and 17-001201 are paired for use in the uplink and 17-001109 and 17-001201 are paired for use in the downlink  The attenuator comprises a 50Ω P.I.N diode, voltage-variable attenuator with a range of 3 to 30dB. The attenuation is controlled by a DC voltage which is derived from the associated detector controller board.
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 354 of 500   Normally the attenuator is at minimum attenuation. The detector/amplifier unit monitors the RF level being delivered by the power amplifier, and when a certain threshold is reached it begins to increase the value of the attenuator to limit the RF output to the (factory set) threshold. Therefore overloading of the power amplifier is avoided.  The factory set threshold is 1dB below the Enhancer 1dB compression point. Some adjustment of this AGC threshold level is possible, a 10dB range is mostly achieved. It is not recommended under any circumstances to adjust the AGC threshold to a level greater than the 1dB compression point as system degradation will occur.  The detector comprises of a 50Ω transmission line with a resistive tap which samples a small portion of the mainline power. The sampled signal is amplified and fed to a conventional half wave diode rectifier, the output of which is a DC voltage proportional to the RF input signal.  This DC voltage is passed via an inverting DC amplifier with integrating characteristics, to the output, which drives the attenuation control line of the corresponding AGC attenuator. This unit is fitted at some earlier point in the RF circuit.  For small signals, below AGC onset, the output control line will be close to 12V and the AGC attenuator will have minimum attenuation. As the signal level increases the control line voltage will fall, increasing the attenuator value and keeping the system output level at a constant value.  AGC Specification (both types)  PARAMETER  SPECIFICATION Frequency range up to 1000MHz Attenuation range 3 to 30dB  Attenuation steps continuously variable VSWR better than 1.2:1 RF Connectors SMA female attenuator 1W Power handling  detector/amp >30W (or as required) operation -10°C to +60°C Temperature range  storage -20°C to +70°C attenuator pcb 50 x 42 x 21mm Size  detector/amp pcb 54 x 42 x 21mm attenuator 90grams Weight  detector/amp 100grams        19.3.3.9. 12V (Single) Relay Board (80-008901)  The General Purpose Relay Board allows the inversion of signals and the isolation of circuits. It is equipped with a single dual pole change-over relay RL1, with completely isolated wiring, accessed via a 15 way in-line connector.  The relay is provided with polarity protection diodes and diodes for suppressing the transients caused by "flywheel effect" which can destroy switching transistors or induce spikes on neighbouring circuits. It’s common use is to amalgamate all the alarm signals into one, volts-free relay contact pair for the main alarm system.
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 355 of 500   80-008901 Specification  PARAMETER  SPECIFICATION Operating voltage 8 to 30V (floating earth) Alarm threshold Vcc - 1.20 volt +15% Alarm output relay contacts Max. switch current 1.0Amp Max. switch volts 120Vdc/60VA Max. switch power 24W/60VA Min. switch load 10.0µA/10.0mV Relay isolation 1.5kV Mechanical life >2x107 operations Relay approval BT type 56 Connector details Screw terminals operational -10°C to +60°C Temperature range  storage -20°C to +70°C     19.3.3.10. Dual Diode Assembly (94-100004)  The purpose of these dual diode assemblies is to allow two DC voltage sources to be combined, so that the main DC rail within the equipment can be sourced from either a mains driven PSU, or externally through an XLR connector or from dual mains driven PSUs. They are very heavy-duty diodes and they prevent any reverse current from flowing back to their source or the alternative supply rail. Combining diodes such as these will also be used if the equipment is to be powered from external back-up batteries.    19.3.3.11. DC/DC Converter 96-200047  96-200047 is an O.E.M. high power device with a wide input range and 12.5 amp @ 12V (150Watts) output capability used to derive a 12V fixed voltage power supply rail from a higher voltage supply, in this case 12V. In the event of failure this unit should not be repaired, only replaced.  96-200047 Specification  PARAMETER  SPECIFICATION DC Input Voltage range 19 to 36V DC Output voltage 12V ± 1% Max. current load 12.5Amps Operation -10°C to +60°C Temperature range  Storage -20°C to +85°C Working Humidity 20 to 90% RHNC
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 356 of 500   19.3.3.12. 12V Switch-Mode PSU (96-300052)  No routine maintenance of the PSU is required. If a fault is suspected, then the output voltage from the power supply may be measured on its output terminals. This is typically set to 12.2V. The adjustment potentiometer will be found close to the DC output terminals.  All the PSUs used in AFL Cell Enhancers are capable of operation from either 110 or 220V nominal AC supplies. The line voltage is sensed automatically, so no adjustment or link setting is needed by the operator.  96-300052 Specification  AC Input Supply  110 or 220V nominal Voltage 85 - 265V AC  (absolute limits) Frequency 47 to 63Hz DC Output Supply  12V DC (nominal) Voltage 10.5-13.8V (absolute limits) Current 12.5A
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 357 of 500   19.3.4.  700MHz Line Amplifier (55-165702)  5U rack mount case   700MHz Line Amplifier (55-165702) List of Major Components  Section  Component Part  Component Part Description  Qty Per Assembly19.3.4.3.  02-007206  900MHZ 8POLE 25MHz+ B/W "SMA"  4 19.3.4.4.  07-015105  ASYMMETRIC CPLR 30dB 800-2500MHz GA  1 19.3.4.5.  10-000901  SW ATT 0-15dB 0.25W SMA F  2 19.3.4.6.  11-006702  800-1000MHz LNA 29dB (cw RELAY) KIT  1 19.3.4.7.  12-021901  Low Power Amplifier  2 17-001109*  AGC Detector Assembly (Logarithmic)  1 17-001117*  AGC Detector Assembly   1 19.3.4.8. 17-001201*  AGC Attenuator Assembly   2 19.3.4.9.  80-008901  12V RELAY PCB ASSEMBLY  1 19.3.4.10.  94-100004  STPS12045TV 60A DUAL DIODE  1 19.3.4.11. 96-200047  DC/DC Converter  1 19.3.4.12.  96-300052  JWS150-12/A PSU (COUTANT LAMBDA)  1  *The sub components 17-001109, 17-001117 & 17-001201 are parts of the Automatic Gain Control (AGC) system used in 700MHz Line Amplifier (55-165702); 17-001117 and 17-001201 are paired for use in the uplink and 17-001109 and 17-001201 are paired for use in the downlink
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 358 of 500   19.3.4.1.  700MHz Line Amplifier (55-165702) Outline Drawing Drawing Number 55-1657102
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 359 of 500   19.3.4.2.  700MHz Line Amplifier (55-165702) System Diagram  Drawing Number 55-165782
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 360 of 500   19.3.4.3.  Bandpass Filter (02-007206)  The bandpass filters are multi-section designs with a bandwidth dependent upon the passband frequencies, (both tuned to customer requirements). The response shape is basically Chebyshev with a passband design ripple of 0.1dB. The filters are of slot coupled, folded combline design, and are carefully aligned during manufacture in order to optimise the insertion loss, VSWR and intermodulation characteristics of the unit. The tuned elements are silver-plated to reduce surface ohmic losses and maintain a good VSWR figure and 50Ω load at the input and output ports.  Being passive devices, the bandpass filters should have an extremely long operational life and require no maintenance. Should a filter be suspect, it is usually most time efficient to replace the module rather than attempt repair or re-tuning.  No adjustments should be attempted without full network sweep analysis facilities to monitor both insertion loss and VSWR simultaneously.  02-007206 Specification  PARAMETER  SPECIFICATION Response type Chebyshev Frequency range 800 - 950MHz * Bandwidth 25MHz * Number of sections 8 Insertion loss 1.2 dB VSWR better than 1.2:1 Connectors SMA female Power handling 100W max operation -20°C to +60°C Temperature range  storage -40°C to +70°C Weight 3 kg (typical)  *tuned to Customer's specification     19.3.4.4. Wideband Asymmetric Coupler (07-015105)  The purpose of Wideband Asymmetric Coupler (07-015105) is to tap off a known portion (in this case 30dB) of RF signal from transmission lines and to combine them, for example through splitter units for different purposes (alarms/monitoring etc.), whilst maintaining an accurate 50Ω load to all ports/interfaces throughout the specified frequency range. They are known formally as directional couplers as they couple power from the RF mainline in one direction only.   07-015105 Specification  PARAMETER  SPECIFICATION Construction Inductive air gap Frequency 800-2500MHz Through loss 0.4dB (typical) Coupling level -30dB ±0.5dB Isolation N/A Weight <1.0kg Connectors SMA, female operation -20°C to +60°C Temperature range  storage -40°C to +70°C
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 361 of 500   19.3.4.5. Switched Attenuator 0.25W, 0 - 15dB (10-000901)  In many practical applications for Cell Enhancers etc., the gain in each path is found to be excessive. Therefore, provision is made within the unit for the setting of attenuation in each path, to reduce the gain.  10-000901 provides attenuation from 0 - 15dB in 2 dB steps The attenuation is simply set using the four miniature toggle switches on the top of each unit. Each switch is clearly marked with the attenuation it provides, and the total attenuation in line is the sum of the values switched in. They are designed to maintain an accurate 50Ω impedance over their operating frequency at both input and output.  10-000901 Specification  PARAMETER  SPECIFICATION Attenuation Values 0-15dB Attenuation Steps 1, 2, 4 and 8dB Power Handling 0.25 Watt Attenuation Accuracy ± 1.0 dB Frequency Range DC to 1GHz Impedance 50Ω Connectors SMA VSWR 1.3:1 Weigh 0.2kg operation -20°C to +60°C Temperature range  storage -40°C to +70°C   19.3.4.6.  Low Noise Amplifier (11-006702)  The Gallium-Arsenide low noise amplifiers used in 800MHz Line Amplifier (55-165703) are double stage, solid-state low noise amplifiers. Class A circuitry is used throughout the units to ensure excellent linearity and extremely low noise over a very wide dynamic range. The active devices are very moderately rated to provide a long trouble-free working life. There are no adjustments on these amplifiers, and in the unlikely event of a failure, then the complete amplifier should be replaced. This amplifier features its own in-built alarm system which gives a volt-free relay contact type alarm that is easily integrated into the main alarm system.  11-006702 Specification  PARAMETER  SPECIFICATION Frequency range 800 – 1000MHz Bandwidth <200MHz Gain 29dB (typical) 1dB Compression point 20dBm OIP3 33dBm Input/Output return loss >18dB Noise figure 1.3dB (typical) Power consumption 180mA @ 24V DC Supply voltage 10-24V DC Connectors SMA female operational -10°C to +60°C Temperature range:  storage -20°C to +70°C Size 90 x 55 x 30.2mm Weight 290gms (approximately)
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 362 of 500  7 8 961 2 3 4 59-Way Pin-Out Graphical Representation Low Noise Amplifier (11-006702) ‘D’ Connector Pin-out details  Connector pin  Signal 1  +Ve input (10-24V) 2 GND 3  Alarm RelayO/P bad 4  Alarm Relay common 5  Alarm Relay good 6 No connection 7  TTL voltage set 8  TTL alarm/0V (good) 9  O/C good/0V bad                 19.3.4.7.  Low Power Amplifier (12-021901)  The low power amplifier used is a triple stage solid-state low-noise amplifier. Class A circuitry is used in the unit to ensure excellent linearity over a very wide dynamic range. The three active devices are very moderately rated to provide a long trouble-free working life.  Its housing is an aluminium case (Iridite NCP finish) with SMA connectors for the RF input/output and a D-Type connector for the power supply and the Current Fault Alarm Function. There are no adjustments on this amplifier, and in the unlikely event of failure then the entire amplifier should be replaced.  Low Power Amplifier (12-021901) Specification  PARAMETER  SPECIFICATION Frequency range 800-960MHz* Bandwidth 20MHz * Maximum RF output >1.0 Watt Gain 15dB 1dB compression point +30.5dBm 3rd order intercept point +43dBm Noise Figure <6dB VSWR better than 1.5:1 Connectors SMA female Supply 500mA @ 10-15V DC operational -10°C to +60°C Temperature range  storage -20°C to +70°C Weight 0.5 kg Size 167x52x25mm * Tuned to Customer’s specification
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 363 of 500   Low Power Amplifier (12-021901) 7-Way Connector Pin-outs  Connector Pin  Signal A1 (large pin)  +24V DC A2 (large pin)  GND 1  Alarm relay common 2  TTL alarm/0V good 3  Alarm relay contact (bad) 4  Alarm relay contact (good) 5  O/C good/0V bad (TTL)                     19.3.4.8.  Automatic Gain Control  17-001109  AGC Detector Assembly (Logarithmic) 17-001117  AGC Detector Assembly  17-001201  AGC Attenuator Assembly   The sub components 17-001109, 17-001117 & 17-001201 are parts of the Automatic Gain Control (AGC) system used in 700MHz Line Amplifier (55-165702); 17-001117 and 17-001201 are paired for use in the uplink and 17-001109 and 17-001201 are paired for use in the downlink  700MHz Line Amplifier (55-165702) is fitted with two differing types of Automatic Gain Control (AGC) system, one linear, and one logarithmic. The AGC with logarithmic detector (17-001117) is fitted in the uplink path and the AGC with linear detector (17-001109) is fitted in the downlink path   The AFL Automatic Gain Control system consists of two units, a detector/amplifier and an attenuator. The detector/amplifier unit is inserted in the RF path on the output of the power amplifier, and the attenuator is situated in the RF path between the 1st and 2nd stages of amplification.  17-001117 and 17-001201 are paired for use in the uplink and 17-001109 and 17-001201 are paired for use in the downlink  The attenuator comprises a 50Ω P.I.N diode, voltage-variable attenuator with a range of 3 to 30dB. The attenuation is controlled by a DC voltage which is derived from the associated detector controller board.
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 364 of 500   Normally the attenuator is at minimum attenuation. The detector/amplifier unit monitors the RF level being delivered by the power amplifier, and when a certain threshold is reached it begins to increase the value of the attenuator to limit the RF output to the (factory set) threshold. Therefore overloading of the power amplifier is avoided.  The factory set threshold is 1dB below the Enhancer 1dB compression point. Some adjustment of this AGC threshold level is possible, a 10dB range is mostly achieved. It is not recommended under any circumstances to adjust the AGC threshold to a level greater than the 1dB compression point as system degradation will occur.  The detector comprises of a 50Ω transmission line with a resistive tap which samples a small portion of the mainline power. The sampled signal is amplified and fed to a conventional half wave diode rectifier, the output of which is a DC voltage proportional to the RF input signal.  This DC voltage is passed via an inverting DC amplifier with integrating characteristics, to the output, which drives the attenuation control line of the corresponding AGC attenuator. This unit is fitted at some earlier point in the RF circuit.  For small signals, below AGC onset, the output control line will be close to 12V and the AGC attenuator will have minimum attenuation. As the signal level increases the control line voltage will fall, increasing the attenuator value and keeping the system output level at a constant value.  AGC Specification (both types)  PARAMETER  SPECIFICATION Frequency range up to 1000MHz Attenuation range 3 to 30dB  Attenuation steps continuously variable VSWR better than 1.2:1 RF Connectors SMA female attenuator 1W Power handling  detector/amp >30W (or as required) operation -10°C to +60°C Temperature range  storage -20°C to +70°C attenuator pcb 50 x 42 x 21mm Size  detector/amp pcb 54 x 42 x 21mm attenuator 90grams Weight  detector/amp 100grams    19.3.4.9. 12V (Single) Relay Board (80-008901)  The General Purpose Relay Board allows the inversion of signals and the isolation of circuits. It is equipped with a single dual pole change-over relay RL1, with completely isolated wiring, accessed via a 15 way in-line connector.  The relay is provided with polarity protection diodes and diodes for suppressing the transients caused by "flywheel effect" which can destroy switching transistors or induce spikes on neighbouring circuits. It’s common use is to amalgamate all the alarm signals into one, volts-free relay contact pair for the main alarm system.
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 365 of 500   80-008901 Specification  PARAMETER  SPECIFICATION Operating voltage 8 to 30V (floating earth) Alarm threshold Vcc - 1.20 volt +15% Alarm output relay contacts Max. switch current 1.0Amp Max. switch volts 120Vdc/60VA Max. switch power 24W/60VA Min. switch load 10.0µA/10.0mV Relay isolation 1.5kV Mechanical life >2x107 operations Relay approval BT type 56 Connector details Screw terminals operational -10°C to +60°C Temperature range  storage -20°C to +70°C    19.3.4.10. Dual Diode Assembly (94-100004)  The purpose of these dual diode assemblies is to allow two DC voltage sources to be combined, so that the main DC rail within the equipment can be sourced from either a mains driven PSU, or externally through an XLR connector or from dual mains driven PSUs. They are very heavy-duty diodes and they prevent any reverse current from flowing back to their source or the alternative supply rail. Combining diodes such as these will also be used if the equipment is to be powered from external back-up batteries.    19.3.4.11. DC/DC Converter 96-200047  96-200047 is an O.E.M. high power device with a wide input range and 12.5 amp @ 12V (150Watts) output capability used to derive a 12V fixed voltage power supply rail from a higher voltage supply, in this case 12V. In the event of failure this unit should not be repaired, only replaced.  96-200047 Specification  PARAMETER  SPECIFICATION DC Input Voltage range 19 to 36V DC Output voltage 12V ± 1% Max. current load 12.5Amps Operation -10°C to +60°C Temperature range  Storage -20°C to +85°C Working Humidity 20 to 90% RHNC
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 366 of 500   19.3.4.12. 12V Switch-Mode PSU (96-300052)  No routine maintenance of the PSU is required. If a fault is suspected, then the output voltage from the power supply may be measured on its output terminals. This is typically set to 12.2V. The adjustment potentiometer will be found close to the DC output terminals.  All the PSUs used in AFL Cell Enhancers are capable of operation from either 110 or 220V nominal AC supplies. The line voltage is sensed automatically, so no adjustment or link setting is needed by the operator.  96-300052 Specification  AC Input Supply  110 or 220V nominal Voltage 85 - 265V AC  (absolute limits) Frequency 47 to 63Hz DC Output Supply  12V DC (nominal) Voltage 10.5-13.8V (absolute limits) Current 12.5A
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 367 of 500   20 CONVENTION PLACE STATION 700MHZ BDA (80-330554-1)   Rack number CR1-CR-06  Convention Place Station 700MHz BDA (80-330554-1) List of major Components  Section  Component Part  Component Part Description  Qty Per Assembly 20.3.1.  50-132103  700MHz Output Duplexer/Combiner  1 20.3.2.  50-132105  700MHz 5 Cavity Combiner System  1 20.3.3.  50-132106  700MHz 4 Cavity Combiner System  1
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 368 of 500   20.1  Convention Place Station 700MHz BDA (80-330554-1) Outline Drawing  Drawing number 80-330554
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 369 of 500   20.2. Convention Place Station 700MHz BDA (80-330554-1) System Diagram Drawing number 80-330584-1
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 370 of 500   20.3  Convention Place Station 700MHz BDA (80-330554-1) Major Components  20.3.1.  700MHz Output Duplexer/Combiner (50-132103)  3U rack mount tray  700MHz Output Duplexer/Combiner (50-132103) List of Major Components   Section  Component Part  Component Part Description  Qty Per Assembly20.3.1.3. 02-007206  Bandpass Filter  2 20.3.1.4.  05-003007  4 Port Hybrid Coupler  1 20.3.1.5.  07-015105  Wideband Asymmetric Coupler  1 20.3.1.6. 09-000902  Dummy Load  1
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 371 of 500   20.3.1.1.  700MHz Output Duplexer/Combiner (50-132103) outline drawing  Drawing number 50-1321103
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 372 of 500   20.3.1.2.  700MHz Output Duplexer/Combiner (50-132103) system diagram  Drawing number 50-132183
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 373 of 500   20.3.1.3.  Bandpass Filter (02-007206)  The bandpass filters are multi-section designs with a bandwidth dependent upon the passband frequencies, (both tuned to customer requirements). The response shape is basically Chebyshev with a passband design ripple of 0.1dB. The filters are of slot coupled, folded combline design, and are carefully aligned during manufacture in order to optimise the insertion loss, VSWR and intermodulation characteristics of the unit. The tuned elements are silver-plated to reduce surface ohmic losses and maintain a good VSWR figure and 50Ω load at the input and output ports.  Being passive devices, the bandpass filters should have an extremely long operational life and require no maintenance. Should a filter be suspect, it is usually most time efficient to replace the module rather than attempt repair or re-tuning.  No adjustments should be attempted without full network sweep analysis facilities to monitor both insertion loss and VSWR simultaneously.  02-007206 Specification  PARAMETER  SPECIFICATION Response type Chebyshev Frequency range 800 - 950MHz * Bandwidth 25MHz * Number of sections 8 Insertion loss 1.2 dB VSWR better than 1.2:1 Connectors SMA female Power handling 100W max operation -20°C to +60°C Temperature range  storage -40°C to +70°C Weight 3 kg (typical)  *tuned to Customer's specification    20.3.1.4.  4 Port Hybrid Coupler (05-003007)  This transmitter hybrid coupler is a device for accurately matching two or more RF signals to single or multiple ports, whilst maintaining an accurate 50Ω load to all inputs/outputs and ensuring that the insertion losses are kept to a minimum. Any unused ports should be terminated with an appropriate 50Ω load. In this specific instance one port of 4 Port Hybrid Coupler (05-003007) is terminated with Dummy Load 09-000902 (see below).  05-003007 Specification  PARAMETER  SPECIFICATION Frequency range 700-900MHz Bandwidth 200MHz Rejection >14dB Insertion loss 6.5dB (in band, typical) Connectors SMA Weight <1.0kg operational -10%C to +60%C Temperature range  storage -20%C to +70%C
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 374 of 500   20.3.1.5. Wideband Asymmetric Coupler (07-015105)  The purpose of Wideband Asymmetric Coupler (07-015105) is to tap off a known portion (in this case 30dB) of RF signal from transmission lines and to combine them, for example through splitter units for different purposes (alarms/monitoring etc.), whilst maintaining an accurate 50Ω load to all ports/interfaces throughout the specified frequency range. They are known formally as directional couplers as they couple power from the RF mainline in one direction only.   07-015105 Specification  PARAMETER  SPECIFICATION Construction Inductive air gap Frequency 800-2500MHz Through loss 0.4dB (typical) Coupling level -30dB ±0.5dB Isolation N/A Weight <1.0kg Connectors SMA, female operation -20°C to +60°C Temperature range  storage -40°C to +70°C    20.3.1.6.  Dummy Load 09-000902  When a combiner system is used to split or combine RF signals, in many cases it is most cost effective to use a standard stock item 4, 6 or 8 port device where, in fact, only a 3 or 6 port device is needed. In this case 4 Port Hybrid Coupler (05-003007) has one of its ports terminated with an appropriate Dummy Load in order to preserve the correct impedance of the device over the specified frequency range.  09-000902 specification  PARAMETER  SPECIFICATION Frequency Range 0 - 2500 MHz Power Rating 25 Watts continuous VSWR Better than 1.1:1 Impedance 50 Ohms Temperature Range -20 to +60°C RF Connectors N Type female Dimension 110.3mm x 38.1mm x Weight 485 grams Finish Black Anodised RF Connector N Type male Environmental IP66 MTBF >180,000 hours
STTRS DOCUMENTATION  Document Number 80-330501HBKM – Issue A - Draft  Page 375 of 500   20.3.2.  700MHz 5 Cavity Combiner System (50-132105)  700MHz 5 Cavity Combiner System (50-132105) consists of 5 Dielectric Cavity Resonators mounted on two 3U rack mount panels, three on one panel and two on the other    700MHz 5 Cavity Combiner System (50-132105) List of Major Components  section  Component Part  Component Part Description  Qty Per Assembly 20.3.2.3.  04-003402  Dielectric Cavity Resonator  5