AwarePoint B2 Wireless Bridge for an Indoor Positioning System User Manual aware

AwarePoint Corporation Wireless Bridge for an Indoor Positioning System aware

User Manual

        Awarepoint Bridge B2  Installation Manual  Date: 02/14/2008    Document History    Date Author  Changes 02/14/2008 Derek Smith Initial Draft                   Awarepoint  Corporation   225 Broadway,  Suite  1670   San  Diego,  CA    92101   www.awarepoint.com
  2    Copyright   Copyright  2008  Awarepoint  Corporation   All  rights  reserved.  This  product  or   document  is  protected  by   copyright  and  distributed  under  licenses  restricting  its  use,  copying,  distribution,  and  decompilation.  No  part  of  this  product  or  document  may  be  reproduced  in  any  form  by  any  means  without  prior  written  authorization  of  Awarepoint  and  its  licensors,  if  any.    Awarepoint,  the  Awarepoint  logo,  and  Real-time  Awareness  Solution,  are  trademarks  or   registered  trademarks  of  Awarepoint  Corporation  in  the  United  States  and  in  other  countries.     FCC  Compliance    Awarepoint  Bridge  model  B2  FCC  ID:  UAG-B2    This  device  complies  with  Part  15  of  the  FCC  Rules.  Operation  is  subject  to  the  following  two   conditions:  (1)  this  Device  may  not  cause  harmful  interference  and  (2)  this  Device  must  accept  any  interference  received,  including  Interference  that   may  cause  undesired  operation.   CAUTION:  Changes  or  modifications  not  expressly  approved  by  the  party  responsible  for  compliance  could  void  the  user's  authority  to  operate  the  equipment.    CAUTION:   This  manual  describes  installation  procedures  for  electrical  equipment.   Proper  precautions  are  required.     Particular  attention  should  be  given  to  text  highlighted  with  the  following  symbol:       Antenna Used: This device has been designed to operate with the  antenna listed below, and having a maximum gain of 2 dBi. Antennas not included in this list or having a gain greater than 2 dBi are strictly prohibited for use with this device. The required antenna impedance is 50 ohms. Pulse W1030  This equipment has been tested and found to comply with the limits for a Class A digital device,   pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection   against harmful interference when the equipment is operated in a commercial environment.  This equipment generates, uses, and can radiate radio frequency energy and, if not installed  and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful  interference in which case the user will be required to correct the interference at his own expense.        Awarepoint Bridge model B2 © 2008 Awarepoint Corporation Installation Manual
  3    Table  of  Contents   Section   Page  1    Introduction ............................................................................................................ 4 1.1 Overview ... ..................................................................................................... 4 1.2 Preparing for Installation - Read this First! .................................................. 4 1.2.1 System Hardware ............................................................................................ 4 1.2.2 Information ...................................................................................................... 4 1.3 System Components ... ................................................................................. 4 1.3.1 Awarepoint Bridge ............................................................................................ 5 2    Awarepoint Bridge Installation ... ....................................................................... 6 2.1 Physical Installation ....................................................................................... 6 2.2 Connect to the Serial Interface ... ................................................................. 6 2.3 Configure Network Interface ... ..................................................................... 6 2.4 Place Bridge on Map ..................................................................................... 7 3    Troubleshooting .................................................................................................... 8 3.1 Awarepoint Bridge ......................................................................................... 8                                  Awarepoint Bridge model B2 © 2008 Awarepoint Corporation Installation Manual
 4    1 Introduction Customer  support:  1-888-TAGIT-NOW   1.1 Overview This  system  installation  manual  is  for  an  Awarepoint  employee  or  Awarepoint  trained service  provider  who  intends  to  install  the  Awarepoint  Bridge  model  B2.   1.2 Preparing for Installation - Read this First!  1.2.1 System Hardware Prior  to  installation,  you  will  need  the  following  system  hardware.    Awarepoint  Bridge(s),  including:   •   Power  Supply   •   Ethernet  Cable  (Cat  3  or  better,  length  to  be  determined  by  site  requirements)    1.2.2 Information Prior  to  installation,  you  will  need  the  following  information:   ƒ   IP  Addressing:  DHCP  or  Static.  If  using  Static  addressing  then:  IP  Address,  Default    Gateway,  and  Subnet  Mask.   ƒ   IP  Address  of  Awarepoint  Appliance   ƒ   Location,  with  an  Ethernet  port  that  has  been  tested  and  configured  to  work    with  10  Base-T,  full  duplex  Ethernet.  (  A  10/100  autosense  setting  should  be    adequate)    1.3 System Components The  Awarepoint  Real-time  Awareness  Solution  consists  of  several  components  as  shown  in  the  diagram  below.  The  parts  of  the  system  that  require  installation  include  Awarepoint  Tags,  Awarepoint  Sensors,  Awarepoint  Bridges,  and  the  Awarepoint  Appliance.  The  Awarepoint  Appliance  contains  all  software  necessary  for  system  operation.        Awarepoint Bridge model B2 © 2008 Awarepoint Corporation Installation Manual
  5                                 Figure 1-1.1: System Diagram  The  System  is  configured  using  the  System  Manager,  a  Java  application  that  runs  on  a  PC  connected  to  the  facility  LAN.  The  System  Manager  may  be  downloaded  from  the Awarepoint  Appliance.    1.3.1 Awarepoint Bridge The  Bridge  model  B2  is  shown.                Figure  1.1-2:  Awarepoint  Bridge  model  B2   The  connectors  on  the  bottom  of  the  bridge  are  (Left  to  Right)  Network  Interface,  Power Connector,  and  Serial  Port.  The  Network  Interface  connects  the  Bridge  to  the  Ethernet  network,  according  to  IEEE  standard  802.3.  The  power  connector  connects  to  the  Awarepoint  power  adapter.  The  Serial  Port  is  used  for  configuring  the  Bridge.  The  serial  interface  operates  on  38,400  baud  with  8  data  bytes,  1  stop  bit,  and  no  parity.      Awarepoint Bridge model B2 © 2008 Awarepoint Corporation Installation Manual
  6   2 Awarepoint Bridge Installation  2.1 Physical Installation Find  a  suitable  location  for  the  Bridge.  Mounting  in  switch  closets  is  preferred,  as  the  Bridge  is  less  likely  to  be  disturbed.  You  will  need  one  power  outlet  and  one  Ethernet  port.  Prior  to  installing  the  Bridge,  read  its  MAC  address  from  the  bottom.  Indicate  on  a  paper  copy  of  the  map  where  this  Bridge  is  located  along  with  its  MAC  address.   Attach  double-sided  tape  to  each  corner  on  the  bottom  of  the  Bridge  and  press  the  Bridge  against  the  surface  to  affix  it.    2.2 Connect to the Serial Interface Connect  a  serial  cable  between  the  Bridge  and  the  computer  you  will  use  to  configure  the  Appliance  (normally  your  laptop  computer).   Open  a  terminal  program  (e.g.  TeraTerm)  and  set  the  serial  port  on  your  computer  to:   •   Baud:  38,400  baud   •   Data  Bits:  8   •   Parity:  None   •   Stop  Bits:  1   •   Flow  control:  None   To  do  this  in  Tera  Term,  click  on  Setup:  Serial  Port  and  adjust  the  settings  appropriately  for  the  port  on  your  computer.  Note  -  the  Port  setting  in  the  image  below  may  be  different,  depending  upon  your  computer.             Figure  2-1:  Tera  Term  Serial  Port  Setup    2.3 Configure Network Interface Plug  the  Bridge  into  the  power  outlet.    Open  the  terminal  and  press  the  ‘Enter’  button  three  times.   This  will  initiate  the   configuration  script.  You  should  now  see  boot  information.  When  prompted,  press  ‘c’  to  configure  the  IP  Address  settings.  At  the  prompt,  enter  return  to  accept  the  existing  MAC  address.    Awarepoint Bridge model B2 © 2008 Awarepoint Corporation Installation Manual
  7   At  the  next  prompt,  if  using  DHCP  to  set  the  IP  address  of  the  Bridge  then  press  Y.   Otherwise  (if  you  setting  the  IP  address  with  a  static  IP  address)  press  N,  and  enter  the  IP  Address,  subnet  mask,  and  default  gateway  for  this  Bridge.   Finally,  enter  the  IP  Address  of  the  Appliance.   The  Bridge  will  proceed  to  ping  the  Appliance,  test  communications  with  the  Appliance,and  perform  an  internal  test.  If  the  communications  tests fail, change  the  IP  address  settingsand  retry.  If  the  internal  test  (“Serial  Board  test”)  fails,  replace  the  Bridge.    2.4 Place Bridge on Map Open  the  System  Manager  and  click  on  the  Positioning:  Configuration  tab.   Expand  the  Sensors/Bridges  tree  and  select  the  floor  where  the  Bridge  is  located.     Expand  the  unassigned  section  of  the  Sensors/Bridges  tree.    The  Bridge  you  just  installed  should  show  up  in  the  Unassigned  section  of  the  device  tree.  If  it  is  functioning  correctly,  the  icon  for  the  Bridge  should  be  blue.                  Figure  2-2:  Positioning:  Configuration Tab  Drag  the  Bridge  icon  onto  the  map  and  place  it  where  it  is  located.                    Figure  2-3:  Positioning:  Configuration  Tab  -  Placing  Awarepoint  Bridge   Awarepoint Bridge model B2 © 2008 Awarepoint Corporation Installation Manual
  8   Click  the  Apply  button  to  save  the  changes.    3 Troubleshooting Customer  Support:  1-888-TAGIT-NOW    3.1 Awarepoint Bridge If  the  Bridge  appears  Red  in  the  Positioning:  Configuration  tab  or  on  the  Awarepoint  Network  Operations  Center,  the  Bridge  has  a  problem.  Try  the  following  steps:   1.   From  a  computer  on  the  same  network  as  the  Bridge,  ping  the  Bridge’s  IP  address.  If   this  test  passes,  proceed  to  step  3.   If  this  test  fails,  it  is  likely  the  Bridge  is  disconnected  from  the  network.  Check  that  the  Bridge  is  connected  to  the  Ethernet   network.    2.   From  the  same  computer,  open  a  web  browser  and  go  to  the  Bridge’s  IP  address.   Press  the  ‘Restart  Bridge’  button  and  enter  the  password.   3.   Check  the  status  of  the  Bridge  using  the  system  manger.  If  it  remains  down  ,  contact   Awarepoint  Technical  Support.                                           Awarepoint Bridge model B2 © 2008 Awarepoint Corporation Installation Manual