Applied Wireless Identifications Group MR1824 Sentinel-Prox MR-1824 User Manual install

Applied Wireless Identifications Group Inc. Sentinel-Prox MR-1824 install

Contents

Installation Manual

1Reader Description Last Update: April 9, 1999The Sentinel-Prox MR-1824 Reader is a radio frequency identification (RFID) Reader used in Access ControlSystem.  The Reader consists of a transmit/receive antenna, associated electronics, and a polycarbonate housingwhich encloses the antenna and the electronics.  The inside of the polycarbonate housing is potted with a two-partepoxy to protect the antenna and the electronics against outside environment.Parts Lista.)  Installation sheet, P/N: 004-97-A QTY=1b.) Sentinel-Prox MR-1824 Reader, P/N: 004-20-A QTY=1c.)  #6-32 x 1” Thread-cutting screw, Type 23, P/N: 616PPN23ZP QTY=4d.) Screw hole plug, P/N: 004-27-A QTY=5 (1 spare)Installation Procedure1.) Position the Reader (Item b on Parts List) at desired mounting position on the mounting surface.  Drill four7/64 (0.109)-inch holes for mounting the Reader and one 11/16 (0.688)-inch clearance hole for clearing thecable and the straight-thru fitting according to Figure 1.2.) Connect the Reader and the Panel together according to Figure 2.a.  Mount the Reader to the mounting surface with the provided #6-32x1” Thread-cutting screws, Type 23(Item c on Parts List).  Insert the Screw hole plugs (Item d on Parts List) into the screw clearance holes toconceal the screws. Note: screw hole plugs are designed for one-time use only! Once theplugs are seated, they can not be removed without damaging the plugs.Product Specifications1.) Read Range (Metal Compensated)1  5VDC (280mA peak) Up to 19 inches (48 cm)1  12VDC (700 mA peak) Up to 25 inches (64 cm)2.) Characteristics1  Indoor and Outdoor  UL Listed1  Operating Temperature Range-35° C to 65° C (-31° F to 150° F)1  Operating Humidity 0 to 95% non-condensing3.) Operating Parameters1  Excitation Frequency 125kHz1  Wiegand Output (Standard) 26 bits1  Wiegand Output (Optional) Up to 56 bitsNote: For installation using RS-232 output or combining Wiegand/RS-232, please refer to Operation &Installation Manual, P/N: 004-98-A.  This manual can be downloaded directly from our web page.Do not cycle the power supply ON and OFF in rapid succession.  Each power supply has its unique “decay”characteristics.  Turning the power supply ON and OFF in rapid succession can cause the Microcontroller to lock-Installation Sheet (Wiegand Output Only) – 004-97-ASentinel-Prox Mr-1824 Reader
2up, due to improper initialization.  Always turn the power supply OFF and count 10 seconds before turning ONagain.NOTE: SEE OUR WEB PAGE http://www.awid.com FOR DETAIL INSTALLATION INSTRUCTIONOR FORWARD ALL WRITTEN QUESTIONS TO service@awid.com (ALL QUESTIONS WILL BEANSWERED WITHIN 24 HOURS) OR CALL US AT 1-800-369-5533 FROM 8 A.M. TO 8 P.M.EASTERN STANDARD TIME FOR TECHNICAL ASSISTANCE.FIGURE 1: HOLES DIMENSIONS
3FIGURE 2: WIEGAND FORMAT WIRING DIAGRAM

Navigation menu