Andrew Wireless Innovations Group RPT-MR801BI MR801BI Power and MR801BI SMR Band Repeater User Manual M0079A1A

Andrew Wireless Innovations Group MR801BI Power and MR801BI SMR Band Repeater M0079A1A

Contents

Users manual

User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 110-March-00User’s manual forband or channel selective RepeaterMRx01B Power
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 210-March-00Copyright  MIKOM, Buchdorf 2000All rights reserved.No parts of this publication may bereproduced, stored in a retrieval system, transmitted in any form or byany means, electronical, mechanical photocopying,recording or otherwise, without prior written permission of thepublisher.
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 310-March-00Table of ContentsLIST OF FIGURES AND TABLES 6LIST OF UNIT SPECIFIC ABBREVIATIONS 7CONTENTS OF DELIVERY 7HEALTH AND SAFETY WARNING  8PREAMBLE 91INTRODUCTION 111.1 Intended purpose 111.2 About the MRx01B Power 111.3 Modular design 111.4 Applications 122FUNCTIONAL DESCRIPTION 132.1 General 132.2 Conversion modules 142.3 Mother board 142.4 Control module SM 2009 ( Rev. 07 and higher ) 162.5 Duplexer 202.6 Active combiner 212.7 Measuring aids 212.8 Feedforward amplifier 222.9 Power supply 223FUNCTIONS AND FEATURES 243.1 Band and channel selectivity 24
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 410-March-003.2 Gain setting 243.3 ALC 253.4 CFO 253.5 BITE and alarms 253.5.1 Handling of alarms 273.5.2 Status report 283.5.3 Severity levels 284OPTIONAL EQUIPMENT 294.1 VSWR module 294.2 External alarms 294.3 Modem 304.4 External RF output 314.5 Battery backup module 325INSTALLATION 335.1 Mechanical installation 345.2 Electrical installation 365.2.1 Grounding 365.2.2 Power connection 375.2.3 Connection of the antenna cables 376SETTING TO WORK 396.1 Preparation 396.2 Setting of operational parameters 396.2.1 Manual settings by means of rotary switches 406.2.2 Setting of the attenuation 406.2.3 Settings via personal computer as terminal 426.2.4 Settings via modem 447TROUBLE SHOOTING 457.1 Error indication 457.2 Alarm monitoring with the STATUS HIST command 45
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 510-March-007.3 Power supply 467.4 General remarks 468MAINTENANCE 478.1 General 478.2 Replacement of the fuses (mains) 478.3 Replacement of the power supply fuse 488.4 Replacement of the mains cable 488.5 Replacement of the RAM / RTC battery 498.6 Replacement of the duplexers 508.7 Replacement of conversion modules 508.8 Replacement of the control module SM 2009 538.9 Replacement of power supplies 548.10 Replacement of active combiner modules 558.11 Replacement of feedforward amplifier 559APPENDICES 589.1 Repeater specifications 589.2 Spare parts lists for MRx01B Power 689.2.1 Spare parts list for MR301B Power 689.2.2 Spare parts list for MR401B Power 709.2.3 Spare parts list for MR701B Power 719.2.4 Spare parts list for MR801B Power and MR801Bi Power 739.3 Installation drawing of the Repeater 759.4 Top view of the Repeater (left side , exemplary configuration) 769.5 Top view of the Repeater (right side, exemplary configuration) 779.6 One channel configuration – cabling and block diagram 7810 INDEX 80
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 610-March-00LIST OF FIGURES AND TABLEStable 1-1 List of international sales offices .............................................................................. 10figure 2-1 Block diagram of MRx01B Power.......................................................................... 13figure 2-2 Top view of a conversion module ........................................................................... 14figure 2-3 Top view of a mother board .................................................................................... 15figure 2-4 Configuration of the control module ( Rev.07 and higher ).................................... 18figure 2-5 Configuration of the DIP-Switches ......................................................................... 19figure 2-6 Top view of the duplexers....................................................................................... 20figure 2-7 Top view of the active combiner module................................................................ 21figure 2-8 Top view of the feedforward amplifier ................................................................... 22figure 2-9 Mounting position of power supplies...................................................................... 23figure 2-10 ON / OFF position of external switch ................................................................... 23figure 3-1 Position of rotary switches ...................................................................................... 24table 3-2 List of all available alarms ........................................................................................ 26figure 4-1 Clamps for external alarms...................................................................................... 29figure 4-2 Modem kit ............................................................................................................... 31figure 4-3 Position of external RF output................................................................................. 31figure 4-4 Mounting position of batteries ................................................................................ 32figure 5-1 System description .................................................................................................. 33figure 5-2 Top view and clearance distance............................................................................. 34figure 5-3 Wall mounting brackets........................................................................................... 35figure 5-4 Grounding kit .......................................................................................................... 36figure 5-5 Screw terminal......................................................................................................... 37figure 5-6 Connector panel layout............................................................................................ 38table 6-1 LED indication.......................................................................................................... 39figure 6-2 Position of the DIP-Switch 1 and 2 and RAM/RTC battery ................................... 40figure 6-3 Position of the rotary switches ................................................................................ 41figure 6-4 Rotary switches and label........................................................................................ 41table 6-5 DIP-switch configuration.......................................................................................... 42table 6-6 List of AT commands................................................................................................ 44figure 8-1 Position of power supply fuse ................................................................................. 48figure 8-2 External filter at iDEN module................................................................................ 51figure 8-3 Top view of a conversion module ........................................................................... 51figure 8-4 Position of hex-coded rotary switches..................................................................... 52table 8-5 Address of synthesizer .............................................................................................. 52table 8-6 Adress of synthesizer, conversion modules .............................................................. 52figure 8-7 Position of hex-coded rotary switches..................................................................... 52figure 8-8 Position of control module ...................................................................................... 53figure 8-9 Power supply ........................................................................................................... 54figure 8-10 Position of special-nut M4 .................................................................................... 54figure 8-11 Position of counter sunk screws on active combiner............................................. 55figure 8-12 Position of feedforward amplifier reset board....................................................... 56figure 8-13 Position of feedforward amplifiers........................................................................ 57figure 9-1 Installation drawing of the Repeater........................................................................ 75figure 9-2 Top view of the Repeater (left side, exemplary configuration)............................... 76figure 9-3 Top view of the Repeater (right side, exemplary configuration) ............................ 77figure 9-4 Cabling of one channel Repeater............................................................................. 78figure 9-5 Block diagram of one channel Repeater.................................................................. 79
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 710-March-00LIST OF UNIT SPECIFIC ABBREVIATIONSALC Automatic Level ControlBCCH Broadcast Control ChannelBITE Built In Test EquipmentBTS Base Transceiver StationDL DownlinkETS European Telecommunication StandardId.-No. Ident NumberI²C-Bus  Inter Integrated Circuit Bus (Philips)LMT Local Maintenance TimeoutMR MIKOM RepeaterOMC Operation and Maintenance CentrePABX Private Automatic Branch ExchangePCMCIA Personal Computer Modem Communication International AssociationPSTN Public Switched Telephone NetworkRev RevisionRF  Radio FrequencyRLP Radio Link ProtocolRSSI Receive Signal Strength IndicationRTC Real Time ClockSDA Serial Data Line of I²C-BusSCL Serial Clock Line of I²C-BusUL UplinkUPS Uninterruptable Power SupplyVSWR Voltage Standing Wave RatioCONTENTS OF DELIVERYQty 1Repeater MRx01B PowerQty 1User’s manual for Repeater MRx01B PowerQty 1Software manualQty 1Set of test protocols consisting of an electrical acceptance test protocoland a safety test protocol applying to the power supplyQty 1Spare parts kitQty 1Wall mounting kit
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 810-March-00HEALTH AND SAFETY WARNINGSF Note: The electrical installation has to be performed in accordance with the safetyregulations of the local authorities. Due to safety reasons the electricalinstallation must be performed by qualified personnel. The cover of this unitshould not be opened while power is applied. Subsequent installation,commissioning and maintenance activities that require the unit to bepowered with the cover open shall only be carried out by suitably qualifiedpersonnel.F Note: The grounding of the Unit has to be performed by all means. A groundingbolt is provided at the cabinet in order to connect the earth bonding cable.F Note: The Unit is heavy-weight. Make sure that a suitable mounting surface isused. Only adequate manpower is allowed to handle the system.F Note: ESD precautions have to be observed! Before maintenance work use theavailable grounding system to connect ESD protection measures.F Note: Due to power dissipation the Repeater may heat up the air volume inside thecabinet and reach a very high temperature. Therefore the Repeater must bemounted in the vertical plane to a wall or a mast without additionalenclosure to provide sufficient ventilation. Between the housing and the walla minimum distance must be kept in order to provide air circulation.
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 910-March-00PREAMBLEThe MRx01B Power manual ( Ordering number Id.-No. 151775 ) includes the followingparts:Chapter   1: IntroductionChapter   2: Functional descriptionChapter   3: Functions and featuresChapter   4: Optional equipmentChapter   5: InstallationChapter   6: Setting to workChapter   7: Trouble shootingChapter   8: MaintenanceChapter   9: AppendicesChapter 10: IndexAny intervention has to be performed by authorized persons only. If you need technicalassistance with the Repeater MRx01B Power approach your local sales office or Mikomdirectly.Under consideration of all references given in this manual, the Repeater should be taken intoservice without any complications and should operate trouble-free for a long time.MIKOM GmbHIndustriering 1086675 BuchdorfGermanyTel: +49 (0) 9099 6 90Fax: +49 (0) 9099 69 31email: sales@mikom.comhttp://www.mikom.com
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 10 10-March-00LIST OF INTERNATIONAL SALES OFFICESAllen Telecom Inc. Allen Telecom Pty Ltd Forem France30500 Bruce Industrial Parkway 6 Stuart Street Z.I. des EbisoiresCleveland, Ohio 44 139-3996 Padstow NSW 2211 78370 PlaisirUSA Australia FrancePhone: +1 ( 440 ) 349-8400 Phone: +61 ( 2 ) 9774-4200 Phone: +33 ( 1 )30-79-15-30FAX: +1 ( 440 ) 349-8407 FAX: +61 ( 2 ) 9774-4500 FAX: +33 ( 1 ) 30-55-55-37FOREM S.p.A. AT Singapore AT ChinaVia Archimede N. 22/24 80 Marine Parade Road CITIC Building, # 11-0420041, Agrate Brianza #19-1 Parkway Parade 19 Jianguomenwai AvenueMilan Singapore 449269 BeijingItaly China 100004Phone: +39 ( 039 )605-41 Phone: +65 ( 345 ) 8022 Phone: +86 ( 10 ) 6508-3088FAX: +39 ( 039 ) 605-4477 FAX: +65 ( 345 ) 8033 FAX: +86 ( 10 )6508-3066AT Canada FOREM UK AT Hong Kong1815 Ironstone Manor, # 12 Unit DCastle Industrial Park 1603 Remington Center,23 Hung To road,Pickering, Ontario L1W 3W9Canada Pear Tree LaneNewbury, Berkshire Kwun Tong, KowloonHong KongU.K. RG 14  2EZPhone: +1 ( 905 ) 839-3474 Phone: +44 ( 1635 ) 569-695 Phone: +852 ( 2389 ) 1844FAX: +1 ( 905 ) 839-4663 FAX: +44 ( 1635 ) 569-463 FAX: +852 ( 2389 ) 4864AT IndiaB-256 Ground Floor.Chittaranjan ParkNew Delhi 110019Phone: +91 ( 11 ) 696-3918FAX: +91 ( 11 ) 652-1648MIKOM SwitzerlandTiergartenweg 14710 BalzthalSwitzerlandPhone: +41 ( 6238 ) 61260FAX: +41 ( 6238 ) 61261MIKOM AustriaHimbergerstr. 7/3/12320SchwechatAustriaPhone: +43 ( 1 ) 706 - 3999FAX: +43 ( 1 ) 706 - 39999table 1-1 List of international sales offices
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 11 10-March-001 Introduction1.1 Intended purposeCellular telephone systems transmit signals in two directions between base stations andmobile telephones within the signal coverage area.If weak signal transmissions occur within the coverage area because of indoor applications,topological conditions or distance from the transmitter, a Repeater is used to extendtransmission range. In the downlink path the Repeater picks up the signal from a donorantenna of an existing cell, amplifies and re-transmits it into the desired dark spot. In theuplink direction the Repeater receives signals from mobile stations present in its coveragearea and re-transmits them to the corresponding base station.1.2 About the MRx01B PowerThis repeater bi-directionally amplifies signals between multiple mobiles and a single basestation in the frequency band. It is employed where poor topological conditions cause weakfield strengths. It can provide highly selective amplification of band segments or channels inthe frequency band.MRx01B Power modules can be combined with other repeater modules in order to create amulti-band repeater system. Modules operating in PCS1900, GSM1800, GSM900, orAMPS800 bands are available. When different modules are combined a common antenna andcontrol interface are available.The MRx01B Power can be set-up locally or remotely. A PCMCIA slot for modem operationis an available option. The repeater has a large number of functions that can be monitored andchanged by the operators via a terminal emulation program or the MIKOM OMC softwareplatform. An easy to understand and simple to learn communication language is available tohelp the operator query status reports from the repeater or to change settings.1.3 Modular designThe MRx01B repeater’s modular design provides the flexibility in addressing present andfuture system needs. Each repeater is custom configured. The main unit includes equipmentcommon to all systems ( cabinet, control module, power supply, mother board ). To this mainunit hardware modules are added as needed. In addition to different duplexers, a wide rangeof conversion modules can be selected depending on the used network system.
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 12 10-March-001.4 ApplicationsThe ability to customise the equipment in this way makes it possible to target the MRx01B tospecific needs. For example, the following are some of the application options available withthe MRx01B.• Channel selective or band selective• CDMA or TDMA• iDEN and analog networks• GSM900 or GSM1800• PCS1900
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 13 10-March-002 Functional descriptionThe Repeater MRx01B Power can be equipped from one to four bands or channels dependingon the used technology.The following block diagram shall illustrate the configuration of the system.*: one physical module contains UL and DL**: with more than two modules, the amplifiers are included; both are in one housingfigure 2-1 Block diagram of MRx01B Power2.1 GeneralThe Repeater consists of two amplifier chains, which are connected antiparallel. Thereceive path of one direction is connected to the transmit path of the other direction by afrequency separation unit, in the following denominated as a duplexer, which combinesboth signals to an antenna (see chapter 2.5).After the duplexer the signals get to a pre-amplifier and afterwards to a conversionmodule (see chapter 2.2). Then the signals are combined by the active combiner (seechapter 2.6) and afterwards amplified by the feedforward amplifier (see chapter 2.8),which provides the required output power.
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 14 10-March-00In the feedforward amplifier a power detection measures the output power and controlsthe gain. This is called Automatic Level Control (ALC) and keeps intermodulationsbelow an adjustable value. Finally, the signals are fed to the antenna.2.2 Conversion modulesThe task of the conversion modules is to amplify thereceive signals and to convert them into an intermediatefrequency. The signals, then, proceed a filter stagecomprising of highly selective filters, and run through adigital controllable attenuator. The attenuation can beset in steps of 2 dB, locally or remotely. By using thesame synthesizer frequency, that was used to convert thesignals down to intermediate frequency, theintermediate frequency is mixed up to the originalfrequency.The synthesizer is controlled via an I²C-Bus. In case of abreakdown in mains, gain or frequency data are non-volatile stored in an EEPROM on board.The yellow label on the top shows the current ALC andCFO values related to the module.See figure 2-2 Top view of a conversion module for anexemplary channel or band module.figure 2-2 Top view of a conversion module2.3 Mother boardThe function of the mother board is the communication between the conversion modules andthe control module via the I²C-Bus.In the three and four channel configuration there is a mother board implemented on the left-hand side and on the right-hand side of the Repeater.In the one and two channel configuration of the Repeater there is only one mother boardmounted on the right-hand side (see figure 9-2 and figure 9-3).Mother boards are located underneath the conversion modules.
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 15 10-March-00figure 2-3 Top view of a mother board
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 16 10-March-002.4 Control module SM 2009 ( Rev. 07 and higher )The control module SM 2009 is a DOS compatible micro computer. The wholecommunication between the operator and the Repeater can be done via the control module. Byusing either the RS232 interface in connection with a modem card and a mobile the Repeatercan be controlled remotely or locally by using a VT100 terminal, i.e. a PC emulating theVT100 terminal.Frequency and gain, power down of RF stages and ALC can be controlled and statusmessages can be received remotely. In case a modem or a mobile is connected, automaticalarm messages can be received by the operator.The data transfer between the control module SM 2009 and the mother board is realized bythe I²C-Bus system.The I²C-Bus concept was developed by Philips for the serial connection of integrated circuitswithin one device. Two wires, SDA - serial data and SCL - serial clock, carry informationbetween the devices connected to the bus. Each device is recognized by a unique address andcan operate either as transmitter or receiver. The MRx01B Power I²C-Bus concept is workingwith a bit rate of 1.5 kbit/s.All MRx01B Power configuration parameters are stored in an EEPROM on the controlmodule if a power supply failure occurs.
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 17 10-March-00Functional description:• Second RS-232 port ( Not working yet, do not use it ) ( 01)• Configurable for MR or MOR (Master Unit) by DIP-Switches (02 )• External alarms or PSTN modem selection by DIP-Switches( = replacement of the external alarm cable) ( 03 )• 8 additional TTL inputs ( opto-coupled ) ) ( 04 ) ( Not supported by software )• 8 additional TTL outputs (O.C. or VCC by 1K-pull-up resistor) ( 05 ) ( Not supported bysoftware )• Connector for external temperature sensor ( 06 ) ( Not supported by software )• Integrated Battery Backup Dummy Board incl. M1 Reset ( Id.-No. 143750 ).The switch is required to activate the battery backup. If a battery backup module is used,the switch must be set to ‘BBU’ position, otherwise there is no backup possible ( 07 ).• Soldering point for the PC/MODEM-switch in a Master Unit ( 08 )• Reset jumper ( 09 )• Fixed location for labels for control module ID (Mikom), repeater software (Mikom),board serial number, modem-driver licence ( 10 )• RS232 interface for the connection of a PC or terminal ( local mode ) ( 11 ).
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 18 10-March-00figure 2-4 Configuration of the control module ( Rev.07 and higher )07ON  =  No BBUOFF = BBU inuse0103020910050406+12 Vdcfor themodem0508I2C-busDebuginterf.Modeswitch11LEDsL1, L2LED L3
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 19 10-March-00figure 2-5 Configuration of the DIP-Switches  SW501 ON OFF4SW Download ---3--- ---2Modem mode Local mode1Manual mode SW mode  DIP-Switches are at position OFF  SW802 ON OFF4Ext. Alarm 1 PSTN (a)3Ext. Alarm 2 PSTN (b)2Ext. Alarm 3 PSTN (c)1Ext. Alarm 4 PSTN (d)  SW504ON OFF8VCC O.C.7VCC O.C.6VCC O.C.5VCC O.C.4VCC O.C.3VCC O.C.2VCC O.C.1VCCO.C.  SW503ON OFF8MOR MR7MOR MR6MOR MR5MOR MR4MR MOR3MR MOR2MR MOR1MR MOR
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 20 10-March-002.5 DuplexerThe task of the duplexer is to isolate uplink from downlink, i.e. isolate transmit path fromreceive path. The pass bandwidth of the duplexer is the entire width of the uplink band andthe downlink band.Duplexer with connector to mobile sideDuplexer with connector to BTS sidefigure 2-6 Top view of the duplexers30 dBcoupler30 dBcoupler20 dBcoupler
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 21 10-March-002.6 Active combinerAfter passing through the conversion modules, the signals will be combined by the activecombiner module in the UL and in the DL path. The active combiner will be followed by thefeedforward amplifier.figure 2-7 Top view of the active combiner module2.7 Measuring aidsWith built-in RF probes test signals can be applied or detected. The probes provide a couplingfactor of 30 dB respectivly 20 dB. Each duplexer (uplink and downlink) is equipped with one30 dB coupler, the UL Input duplexer additionally with a 20 dB coupler for a modem ormobile (see chapter 4 Optional equipment). This facilitates measurements under alloperational conditions, while an antenna or a dummy load may be connected.The position of the couplers on the duplexers is shown in figure 2-6 Top view of theduplexers.
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 22 10-March-002.8 Feedforward amplifierThe feedforward amplifier is the final stage which enables high output power as well as a highICP3. One amplifier has to be installed for the uplink and one for the downlink.figure 2-8 Top view of the feedforward amplifier2.9 Power supplyFor the MRx01B Power power four power supplies are necessary.Power supplies are available with different mains power. See list below for available powersupplies.• 115 VAC ± 15% / 40 - 65 Hz• 230 VAC ± 15% / 40 - 65 Hz• 185 - 320 VAC / 40 - 65 Hz• 24 VDC• 42 to 60 VDC• 80 to 130 VDC
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 23 10-March-00The following figure shows the mounting position of the power supplies in theMRx01B Power cabinet.figure 2-9 Mounting position of power suppliesPower supplies can be equipped with a power socket, protected with two fuses. Each powersupply can be switched on or off by means of an external switch. The modules of the Repeaterare voltage free if all power supplies are switched off. The power socket, however, is stillprovided with mains power.F Note: The service connecter must not be used for anything else butservice devices with low power consumption, e.g. a Laptop.See figure 2-10 ON / OFF position of external switch.figure 2-10 ON / OFF position of external switchF Note: To switch the whole Repeater voltage free, you have to remove thefuses F1 and F2 on the screw terminal.The power supply is factory-set and should not be changed.
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 24 10-March-00STYLEREFSEQARABICFunctions and features3.1 Band and channel selectivityThe selectivity is achieved by highly selective filters in the IF part of the band / channelmodules.3.2 Gain settingThe gain can be changed by introducing attenuation into the amplifier chain. By using a rotaryswitch the attenuation can be adjusted locally in the range from 0 dB to 30 dB maximum insteps of 2 dB. The attenuation can be set for the UL and DL path separately.The rotary switches are mounted on the mother board. These switches are accessible throughthe long hole between the two conversion modules (see figure 3-1 Position of rotaryswitches). They can be adjusted easily by means of a small screwdriver.figure 3-1 Position of rotary switchesFor remote control an RS232 interface can be used to set the gain.The functions of the control module may be used locally by means of a VT100 terminal or apersonal computer emulating the VT100 terminal. See also chapter 6.2, which deals withsettings of operational parameters.long hole
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 25 10-March-003.3 ALCIn order to protect the amplifiers from overload and to prevent the system to generate spuriousemission, the amplifiers have an Automatic Level Control, designed to limit the output powerto a defined level. A part of the output power is rectified, amplified and used to control anattenuator network.FNote: The ALC protects the feedforward amplifier. To keep spurious emissionsbelow certain limits, the input power into the Repeater and the attenuationsettings of the repeater have to be considered properly.3.4 CFOEach conversion module has got a different offset of the set center frequency. This offset iscompensated by software settings (see software manuals).These settings are already factoryset and should only be changed when neccessary. The CFO (center frequency offset) is notedon the label on top of the conversion module.3.5 BITE and alarmsThe Built-In TEst concept comprises the monitoring of the power supplies, the operationalcurrents in the conversion modules, the mother board and the remote control interface.Furthermore, the synthesizer lock and the temperature of the Repeater are monitored.There are three multicoloured LEDs mounted on the control module. The LED L3 indicatesthe presence of electrical power of +12VDC in the Repeater. Every alarm is indicated by thefailure LEDs, L1 and L2.For the position of the LEDs on the control module see figure 2-4 Configuration of the controlmodule ( Rev.07 and higher ).All alarms can be checked by typing the ‘STATUS HIST’ command. Minor alarms with noinfluence on the system can be cancelled by typing the ‘ALARMACKN’ command, e.g. ALCactive, VSWR or door open. The following print screen illustrates a possible ‘STATUSHIST’ reportIn case a hardware failure is detected the concerning hardware module has to be replaced. Analarm can be acknowledged manually by software command. If all alarms have beenacknowledged the summary error LEDs are set back to green indication.In case of mains power failure all data of the STATUS HIST list are lost.The alarm can also be sent to the OMC.
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 26 10-March-00If monitored via a modem automatic dialling will generate a summary alarm message. Theoperator can acknowledge the alarm message by a simple ring back and after that he is able torequest a detailed status report.The following list comprises all available alarms in the Repeater. These alarms may occur inthe STATUS HIST list.NO. ALARM NAME ALARM ACTIVE STATUS1AMPLIFIER BIAS FAILURE2POWER SUPPLY 8 V FAILURE3POWER SUPPLY 12 V FAILURE4MAINS FAILURE5SYNTH FAILURE6DOOR OPEN(7) VSWR ALARM8ALC FAILURE9LITHIUM BATTERY VOLTAGE LOW10 OVERTEMP11 INVALID LOGIN ATTEMPT12 I2C BUS FAILURE(13*) EXT. ALARM 1 FAILURE(14*) EXT. ALARM 2 FAILURE(15*) EXT. ALARM 3 FAILURE(16*) EXT. ALARM 4 FAILURE(17**) EXT. BATTERY OVERTEMP.*  Alarm default settings changeable by software instruction SET ALIAS.**  This alarm may be activated together with the external alarms, for instance UPS or temperature(...) Optional alarmstable 3-2 List of all available alarms
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 27 10-March-003.5.1 Handling of alarmsAs soon as the software recognises a valid alarm, a message is transmitted to the OMC.If the repeater is operating in modem mode the alarm message ‘MIKOM> REPEATERREQUIRES OPERATOR ATTENTION’ will be sent via modem to the terminal or the OMC.The first of two stored telephone numbers will be dialled. In case a connection cannot beestablished the second telephone number will be dialled. If this should be unsuccessful aswell, the call will be repeated after a pre-set delay. Default setting is 10 minutes. Therepetition cycle can be set by software.The alarm check routine is searching every 10 seconds for alarms ( polling principal ). Todecide whether an alarm is a valid alarm it must remain for 5 polling cycles, only then it willbe recognized and entered in the alarm history. As soon as the alarm is valid the contacts ofthe alarm relay at the mother board are set. Additionally two summary error LEDs are set tored light to indicate an alarm. These LEDs are mounted on the control module (see figure2-4).The entry in the alarm history describes the alarm type, the time and the date when itoccurred. It is not possible to locate the defect module, only the reason.Entered alarms in the alarm list can be acknowledged by simply ringing back and typing asoftware command. It is also possible to acknowledge alarms in local mode. Acknowledgedalarms will be indicated with ‘-ACK’. As soon as the alarms have been acknowledged thealarm relay will be reset and the summary LEDs switch back to green light again. To switchoff external alarm indication devices can only be done by acknowledging the alarms.If the same alarm cause occurs again, it will be entered in the alarm list ( not acknowledged )after 5 polling cycles. An already acknowledged alarm must have an interruption of at least 5polling cycles to be detected by the software as a new alarm. Only then the alarm will beentered again in the alarm history ( not acknowledged ).All data of the alarm history are lost, if the repeater will be booted by software or if therepeater was disconnected from mains. There exists no command to delete the alarm history,to boot the repeater is the only way to clear the alarm history.The alarm list has a capacity of about 50 alarm entries. If more alarms occur the oldestmessage will be deleted first ( FIFO principal ).In the software exists no alarm clear message, i.e., the repeater sends no message to theterminal or the OMC if an alarm has disappeared by itself.
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 28 10-March-003.5.2 Status reportTwo instructions enable the operator to gain knowledge of the system status. Typing the GETcommand will be responded by a listing of all settings of the Repeater. STATUS will beresponded by a listing of all individual status information.The complete listing of the dialogue language with the processor of the control moduleincluding the instructions to and the messages from the system is available as a separatemanual.3.5.3 Severity levelsThis parameter defines five severity levels for an alarm and can be set in the alarm mask(detailed description in the software manual). The severity levels indicate how the capabilityof the managed object has been affected.The levels are described below and are ordered from most severe to least severe:- Critical: The critical severity level indicates that a service affecting condition hasoccurred and an immediate corrective action is required to restore thecapability of the managed object.- Major: The major severity level indicates that a service affecting condition hasdeveloped and an urgent corrective action is required. Such a severity can bereported, for example, when there is a severe degradation in the capability ofthe managed object and its full capability must be restored.- Minor: The minor severity level indicates the existence of a non-service affecting faultcondition and that corrective actions should be taken in order to prevent a moreserious failure. Such a severity can be reported, for example, when the detectedalarm condition is not currently degrading the capability of the managed object.- Warning: The warning severity level indicates the detection of a potential or impendingservice affecting failure before any significant effect has been caused. Action should be taken to further diagnose and correction of the problem shall preventa more serious service affecting failure.- Disable: The disable severity level indicates that the detected failure has no influence onthe system and shall not be sent to the terminal.
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 29 10-March-004 Optional equipmentThe following modules can be integrated as an option.4.1 VSWR moduleVSWR signal is continually measured by a special VSWR module. An alarm can be given forVSWR < 10 dB.4.2 External alarmsWith the following option it is possible to monitor 4 external alarms via the Repeatersoftware. Hence the status of the connected device, e.g. UPS, can be monitored.The contacts of the alarms can be accessed at clamps on the main board (right-hand side ofthe Repeater).The electrical connection has to beas follows:External alarm 4 (high active)External alarm 3 (high active)External alarm 2 (low acitve)External alarm 1 (low acitve)Groundfigure 4-1 Clamps for external alarmsConfiguration: 5 V / 0.5 mA max. for open collector applications.All external alarms are normally high without connection. Due to the fact that the externalalarms 3 and 4 are high active, they have to be connected to ground to prevent an alarmmessage.
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 30 10-March-00The factory-set response after typing the software command STATUS EXTALARM is forinstance „EXT. ALARM 1 OK“, if the alarm is not active and „EXT. ALARM 1 FAILURE“,if the alarm is active.The name for each external alarm and the name for the alarm message can be defined by thecustomer with the corresponding software command.The following example describes the response for the external alarms to control an UPS.Example: External alarms if the UPS is activeEXTERNAL ALARM STATUSUPS alarm activeBattery low !UPS door openBattery door openor External alarms if the UPS is not activeEXTERNAL ALARM STATUSUPS not activeBattery OKUPS door closedBattery door closedIf the optional external alarms are part of the delivery, they will be switched on by a softwarerelease, i.e. they are distributed via the software.4.3 ModemThe Repeater can be equipped with a modem for the remote control of the repeater. Thisallows the operator to change settings and querry information of the Repeater remotely.See figure 4-2 for the optional modem kit. This kit is available with and without modem.For information referring to the optional modem see chapter 4.4 and chapter 6.2.4.
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 31 10-March-00External RFPCMCIA cardModemfigure 4-2 Modem kit4.4 External RF outputAn external output is available at theoutside of the housing as an option. Thisenables e.g. the connection of anintegrated modem or mobile to anadditional external antenna or it might beused for UL diversity. The connector typeis N female.figure 4-3 Position of external RF output
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 32 10-March-004.5 Battery backup moduleIf backup is required only for the control module and the modem, low capacity batteries areavailable to operate controller and modem for at least ten minutes under normalenvironmental conditions.Battery backup is provided for the control module to transmit alarm information in case ofpower failure. The battery type is a NiCd 8.4V/300 mAh. The battery backup is sufficientenough to support multiple dial out attempts via modem in case of ‘system engaged’ or othercommunication problems for at least ten minutes under normal environmental conditions.F Note: This battery backup module is provided for the control module only.The batteries are protected from deep discharge by use of a low voltage disconnect circuit. Alocal switch is provided to disconnect the battery backup system during maintenance to ensurethat all circuits are voltage-free.The switch is located on the battery backup module.Switch ON (default) OFFBattery backup active Battery backup not activeThe module is directly plugged into the control module. During the charging process a greenLED V7 on the module indicates, that the battery is charged at the moment. After finishingthe process the LED V7 will be switched off.The batteries are mounted underneath the modem mounting plate (see following figure).figure 4-4 Mounting position of batteriesBatteries
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 33 10-March-005  InstallationBTSRX UplinkTX DownlinkMobileTX UplinkRX DownlinkRX DownlinkTX UplinkTX DownlinkRX Uplinkto/fromMobile Stationsto/fromBTSRepeater Systemfigure 5-1 System description
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 34 10-March-005.1 Mechanical installationF Note: Due to power dissipation the Repeater may heat up the air volume insidethe cabinet and reach a very high temperature. Therefore it is necessary to mount theRepeater in the vertical plane to a wall or a mast without additional enclosure to providesufficient ventilation. Between the housing and the wall a minimum distance must bekept in order to provide air circulation.The Repeater must be mounted in thevertical plane to a wall or a mast, whichmeans the connectors have to be located atthe bottom.Use the mounting brackets, which are partof the delivery. This will guarantee aminimum distance between the wall and theRepeater housing. The cabinet must befixed to the wall (brackets) with fourscrews.Check the correspondence of the wallmounting kit and the wall.figure 5-2 Top view and clearance distanceF Note: The weight of the MRx01B Power is approximately 47 kg in standardconfiguration.
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 35 10-March-00Mounting procedure:Dismount the mounting brackets first. They are screwed tight to the housing with four sockethead cap screws M8.0x16 (see figure below) and two tire bolts.figure 5-3 Wall mounting bracketsUse the wall mounting sheet to mark the position of the drilling holes. Drill 4 holes and screwthe mounting brackets to the wall. Attach the upper two socket head cap screws M8.0x16 tothe Repeater housing. Now it is possible to hang the Repeater into the mounting brackets. Fixthen the lower two socket head cap screws M8.0x16 and the 2 tire bolts.F Note: The unit is heavy-weight. Make sure that a suitable mounting surface isused. Only adequate manpower is allowed to handle the system.The installation position of the Repeater follows from the installation drawing (see figure 9-1Installation drawing of the Repeater). Make sure that there is free access to the electricalconnections. The allowed bending radius of the connected cables must not be exceeded.Furthermore the Repeater shall be mounted in a way that there is free access to the individualunits inside the cabinet, while the door of the Repeater is open.Therefore keep a clearance distance of 1 m on each side, on top and below the unit.See figure 5-2 Top view and clearance distance.mounting brackets
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 36 10-March-005.2 Electrical installationFNote: ESD precautions have to be observed! Before working inside the cabinetuse the available grounding system to connect ESD protection measures.The electrical installation has to be performed in accordance with thesafety regulations of the local authorities. Due to safety reasons theelectrical installation must be performed by qualified personnel. Thecover of this unit should not be opened while power is applied.Subsequent installation, commissioning and maintenance activities thatrequire the unit to be powered with the cover open shall only be carriedout by suitably qualified personnel5.2.1 GroundingGrounding has to be performed by all means. Therefore a grounding bolt is provided at thecabinet. An earth bonding cable will be mounted in the factory and will be delivered with theunit. Don’t use the grounding screw for connecting external devices.The complete grounding kit is part of the delivery schedule, see figure 5-4 Grounding kit.figure 5-4 Grounding kit
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 37 10-March-005.2.2 Power connectionA firmly installed mains cable 3 x 1.5 mm² is used, which is fed into the housing through awatertight cable gland. Due to safety reasons the power supply lead has to be protected by two8 A fuses. Inside the Repeater, mains are connected to a screw terminal.See figure 5-5 Screw terminal for the position of the two 8 A fuses.Before connecting electrical power to the Repeater grounding has to be performed. TheRepeater is equipped with a firmly connected power cord 3 x 1.5 mm². Due to safety reasonsthe power supply lead of the Repeater has to be protected with two 8 A fuses, type MT. In theevent the length of the power cord should not be sufficient it can be replaced by a longercable.figure 5-5 Screw terminalF Note: If the power supply lead has to be replaced use a cable of the same quality.5.2.3 Connection of the antenna cablesThe Repeater has two female antenna connectors 7/16 (optionally N). For mounting thecorresponding cable connectors we recommend to refer to the applicable documentation ofthe respective connector manufacturer. The bending radius of the antenna cables must remainwithin its specification. This will warrant proper operation of the system; otherwise changesin the electrical behaviour of the cable might occur which could cause malfunction of theRepeater system.Fuses F1 and F2
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 38 10-March-00F Note:  It is sufficient to fix the 7/16 antenna connectors hand-screwed.Any use of a tool (like tongs) might cause damage to the connectors andthus lead to malfunctioning of the Repeater.There are two 7/16 female antenna connectors at the outside of the housing accessible on theconnector panel (see following figure).figure 5-6 Connector panel layoutThe 7/16 TX-downlink connector should be connected to the antenna system for thecommunication with the mobile units.MobileThe 7/16 TX-uplink connector should be connected to the antenna system for thecommunication with the Base Transceiver Station.BTSAs an option a 7/16 - N adapter is available.
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 39 10-March-006 Setting to work6.1 PreparationF Note: It is not allowed to operate the Repeater without termination of the antenna connections! The termination can be performed by the antenna connection as well as a dummy load or the 50-Ohm-terminated connectionof a measuring instrument.Before bringing the Repeater system into service it is necessary to measure the antennaisolation. The Repeater system has its maximum available gain when the attenuation is set tozero. On site the maximum allowed gain is 15 dB less than the value of the antenna isolation.In order to check the function of the Repeater system on site it is advisable to operate theRepeater system with 50 Ohm termination. This makes it possible to set the necessary gainand to test the set value without the necessity of transmitting on air.In order to perform settings the Repeater has to be opened. Please, ensure not to damage theseals, which are on the modules situated on the conversion modules inside of the Repeater,because this would lead to risk the success of warranty claims.After taking the Repeater into service following signals occur during the boot process.InternalLED L1 InternalLED L2 InternalLED L3 Causegreen red green red green- - - - ll Power on state,Software boot startsll Flashesred shorttimell Flashes redshort time ll Software boot startsll ll ll Software is runningtable 6-1 LED indication6.2 Setting of operational parametersAttenuation of the Repeater can be set manually by means of rotary switches, frequency canbe set locally or remotely.There are three different possibilities to set the operational parameters:-manual settings by means of rotary switches-local control via RS232 interface and PC-remote control via modem
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 40 10-March-006.2.1 Manual settings by means of rotary switchesThe manual mode allows the user to set the required channels and attenuation by means ofrotary switches. With a small screwdriver, which fits through the long holes of the conversionmodules, the values can be adjusted by turning the switch carefully to the desired position.F Note: To enable manual settings of parametersthe mode switch (DIP-Switch 1) has to bechanged from OFF to ON.The DIP-Switch is mounted on the control module, located on the left side of the Repeater.RAM/RTC BatteryDIP-Switch 1  and 2figure 6-2 Position of the DIP-Switch 1 and 2 and RAM/RTC battery6.2.2 Setting of the attenuationThe gain can be set by introducing attenuation into the amplifier chain. By using a rotaryswitch the attenuation can be adjusted locally in the range from 0 dB to 30 dB maximum insteps of  2 dB. The attenuation can be set for the UL and DL path separately.The rotary switches are mounted on the mother board. These switches are accessible throughthe long hole between the two conversion modules (see figure 6-3 Position of the rotaryswitches). They can be adjusted easily by means of a small screwdriver.RS 232 portconnector
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 41 10-March-00figure 6-3 Position of the rotary switchesA label on the conversion module, located next to the rotary switch, illustrates the usage ofthe rotary switch.figure 6-4 Rotary switches and labelF Note: Gain can be changed independently for the uplink and downlink path.long hole
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 42 10-March-00DIP-Switch configuration:DIP-Switch ON OFF (default values)1manual auto2remote mode local mode3n.c. n.c.4software downloadmanually controlled software downloadcontrolled by softwaretable 6-5 DIP-switch configuration6.2.3 Settings via personal computer as terminalInstead of manually setting operational parameters via rotary switches it is also possible to usethe functions of the control module. The local mode for settings via PC has to be set.Therefore the DIP-Switch 2 has to be at position OFF.See figure 6-2 forpostition of DIP switch 2A VT100 terminal or a PC with VT100 emulation can be connected to the control moduleSM2009 by a standard RS232 cable, if necessary in connection with an adapter 9 to 25.See figure 6-2 for position of the RS 232 connector.Cable Connections PC                      -                     Control Module SM20099 contact SUB - D- Connector 9 contact SUB - D- Connectormale malePC               RS 232MRx01B PowerPIN           PIN1  )                                                                        (  12  )                                                                        (  23  )                                                                        (  34  )                                                                        (  45  )                                                                        (  56  )                                                                         (  67  )                                                                        (  78  )                                                                        (  89  )                                                                          (  9DIP-Switch 2
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 43 10-March-00The following communication mode between control module and VT100 is set initially. 9600 baud - 8 bit - no parity -1 stopbitThese settings can only be changed after connection of the terminal. If all wanted settingshave been initialized and a modem has to be used it will be recommended to check whetherthe settings comply with the capabilities of the modem and the line. Modifications arepossible by software commands.F Note: Settings on the Repeater can be performed after the following procedureonly.After connecting the PC to the Repeater, following procedure is necessary to get access to theprogram.MIKOM REPEATER MRx01B Power - SM2009 - SW: REP1007V1.11ENTER <.> <CR> TO LOGIN1. Step:                  Type the two keys ( . ) FULLSTOP and (↵) ENTERYou have to type the keys:2. Step:                  ENTER USER IDYou have to enter: UserID1 ↵F Note: The input is case sensitive, no blanks. After three mistrial followsdisconnection.3. Step:                  ENTER PASSWORDYou have to enter: P-word1 ↵F Note: The input is case sensitive, no blanks. After three mistrials followsdisconnection. ↵↵.
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 44 10-March-006.2.4 Settings via modemThe Repeater can be equipped with a modem. If so, the repeater will be delivered with apreset init string. This init string was used for internal tests. In case no connection can beestablished check the local conditions and change the init string if necessary.The following list contains the description of the AT commands:&F Sets modem to factory configurationE0 Echo OFFS0=1 Auto answer ON; the GSM module / M1 modem goes off-hook after the first ringing signal.S7=60 Waiting time for connection after dialing; permissible valuesare from 0 ... 60.B13 Setting to 9600 bps asynchronous mode\ N6 Auto reliable operation\ N0 Standard operation, no error correction+CBST=7,0,1 Set bearer service type to 9600 bps. Non-transparentconnection (uses RLP)X3 Not waiting for dial tone; usually used at PABX.*P1 Switch ON phone&K4 Enables XON / XOFF flow controltable 6-6 List of AT commands
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 45 10-March-007 Trouble shootingAll Repeaters are factory-set to „Power down disabled“ status, this means the channel groupis active. To switch off the channel group use the software command „PWRDOWN enabled“.(You’ll find a detailed description in the software manual.)7.1 Error indicationl = LED on- = LED offInternalLED L1 InternalLED L2 InternalLED L3 Causegreen red green red green- - - - -No power.Check presence of power atthe input; replace fuseaccording to chapter 8.3,check battery backup modulel l l Indicates asummary failure7.2 Alarm monitoring with the STATUS HIST commandCheck alarms with ‘status hist‘ command.1.  If a hardware module is damaged, replace corresponding hardware module.2.  Minor alarms with no influence on the system can be cancelled by confirming the alarmwith the ‘alarmackn’ command, e.g., ALC active, VSWR, RSSI or DOOR OPEN.3.  If all alarms have been acknowledged the summary error LEDs will be set back to greenindication.4.  In case of mains power failure the contents of the actual STATUS HIST list is lost.For a complete list of available alarms, see table 3-2 List of all available alarms
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 46 10-March-007.3 Power supplyThe output voltage is factory set and should not be changed.7.4 General remarks• After a software download previous user settings (data default values) might beoverwritten. Before you start a software download save the set values for:- centre frequency- attenuation- ALC threshold- CFO• If an ALC or AMPBIAS alarm occurs during installation or commissioning an user errormight be the cause, due to wrong measurements.
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 47 10-March-008 Maintenance8.1 GeneralF Note:  The Repeater does not require preventative maintenance measures.It is only recommended to replace the RAM/RTC battery after three years usage as aprophylactic measure. The nominal lifetime of these batteries is five years under normalenvironmental conditions.In the event of a malfunction it is advantageous to check the status of the antenna systems aswell as the continuity of the entire cabling including connectors, before replacing themodules.Maintenance on the Repeater shall be performed only by replacing modules. Soldering onprinted circuit boards shall be avoided. In order to sustain warranty take care not to damageunintentionally the seals on the modules.The spare part list, consequently, contains only units, which can be replaced without tuning orcomplex soldering work.F Note:  Defect parts should be replaced by original parts from MIKOM only.All interventions inside the housing are at one’s own risk.During maintenance ensure that the Repeater has been disconnected frommains.Open the lock at the connector panel and remove the cover plate. To open the housing use aTorx key and unscrew the four Torx screws.8.2 Replacement of the fuses (mains)The mains cable is protected with two fuses F1 and F2 8A type MT. They are accessibleinside of the Repeater at the fuse terminal on the right side. Open the screw plug for the fuseand take out the fuse.F Note:  Use only fuses of the same type and the same rating when replacing!See figure 5-5 Screw terminal for position of the 8A fuses.
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 48 10-March-008.3 Replacement of the power supply fuseEach power supply is protected with a fuse 10 A / 35 V. The fuse is mounted outside of thepower supply housing. (see following figure)F Note:  Use only fuses of the same type and the same rating when replacing!figure 8-1 Position of power supply fuse8.4 Replacement of the mains cableThe Repeater will be delivered with a firmly connected mains cable.In case the length of the delivered mains cable should not be sufficient or in case of a defect,the mains cable can be replaced.F Note: Disconnect Repeater from mains first.Remove the clamping profile at the outside of the housingby pulling at the mains cable. Open the PG9 threaded jointwith a spanner size 17. Inside the housing remove theplastic cable clip by unscrewing the tallow-drop screw.Then use a small screwdriver and open the screws of thefuse terminal.
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 49 10-March-00Now the mains cable can be removed by pulling at thecable. For the installation of a new cable  strip theisolation of a new cable to the length of 18 cm. Put thescrew of the cable gland over the cable then use thejoint rubber and pull it over the cable. This willguarantee a tight connection. Now insert the cable.Inside the housing pull an insulated tube with the lengthof 8 cm over the wires. Now close the PG9 threadedjoint. Screw the wires to the fuse terminal. Fix the cablewith the plastic cable clip.Put the cable in the guide shaft and close it with the clamping profile.8.5 Replacement of the RAM / RTC batteryThe RAM / RTC battery of the control module has to be replaced in case of memory loss oras a preventive measure after approximately three years usage. The RAM / RTC battery ismounted on the left-hand side of the Repeater on the control module.REFIf the optional battery backup module and the optional mobile kit are installed, the batterybackup board and the modem-reset board, which are plugged into the control module have tobe removed first.Take off the Lithium battery by means of a small screwdriver, placed between the battery andthe battery socket.The type of the battery is CR 2450 Lithium 3 V / 500mAh, manufacturer is RENATA.After replacement of the RAM battery, the control module has its basic settings, date and timehave to be set to the actual value.For position of the RAM/RTC battery see figure 6-2EMBEDF Note: Before replacing the battery, disconnect the Repeater from mains.Observe the rules for changing Lithium batteries. Wrong connection ortreatment may result in bursting of the battery and dissemination ofhazardous substances.Don’t try to charge this battery
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 50 10-March-008.6 Replacement of the duplexersThis description is valid for the one channel configuration of the Repeater only. For differentconfigurations refer to the assembly guide for the Repeater.Remove the semi-rigid cables which connect the UL output and the DL output with thefeedforward amplifier by loosing the SMA connectors. Use a torque wrench. Then remove thesemi-rigid cables from the conversion modules. (BTS side marked with a red spot).It is recommended not to remove the amplifier which is mounted on the backside of theduplexer. A new duplexer will be delivered with a premounted amplifier.Unscrew the four counter sunk screws M3 at the connector panel of the Repeater. See figure5-6 Connector panel layout.For mounting the duplexers proceed in reverse order.The cables have to be connected like shown in figure 9-4 Cabling of one channel Repeater.8.7 Replacement of conversion modulesTo remove the conversion modules, disconnect the SMA connectors by means of a torquewrench.If the Repeater is equipped with iDEN channel modules, the external filter on top of themodules must be dismounted beforehands. The external filter box covers two of the sockethead cap screws the iDEN module is fixed with.
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 51 10-March-00Unscrew the socket head cap screw on topof the external filter box, remove the box Socket headcarefully and continue the dismounting cap screwprocedure like described below.           figure 8-2 External filter at iDEN moduleUnscrew six socket head cap screws by means of a hex socket key.Pull carefully by means of the mounting strap, fixed on the module and take off the modules.Connecting theconversion modulesdepends on the number ofchannels your Repeater isequipped with, i.e. with one upto four (iDEN: six) channels.Each configuration has got adifferent cabling. See assemblyguide of the channel modificationkits for the cabling and functionaldescription of the conversionmodules dependent on theconfiguration of the Repeaterfigure 8-3 Top view of a conversion module*: iDEN modules are equipped with mounting straps on the left and on the right side.Socket head capscrews Mountingstrap *
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 52 10-March-00For the exchange of a conversion module or the installationof a new conversion module, the slave address of the synthesizerhas to be set. This can be done by means of hex-codedrotary switches mounted on the lower side of the modulesHex-coded rotary switch for ULHex-coded rotary switch for DLThe synthesizer address must be set like shownin the following table:Conversion module AddressUL DLChannel one 0 1Channel two 2 3Channel three 4 5Channel four 6 7figure 8-4 Position of hex-codedrotary switchestable 8-5 Address of synthesizerConversion modules with variable bandwidth have four rotary switches. The synthesizeraddress must be set like shown in the following table:Filter 1 Filter 2UL DL UL DLChannl one 0 1 0 1Channel two 2 3 2 3Channel three 4 5 4 5Channel four 6 7 6 7table 8-6 Adress of synthesizer, conversion moduleswith variable bandwidthfigure 8-7 Position of hex-coded rotary switchesat variable bandwidth moduleFurther instructions for band selective modules with variable bandwith can be found in aseparate document.
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 53 10-March-008.8 Replacement of the control module SM 2009The control module is a Printed Circuit Board situated on the left-hand side of the Repeater.Disconnect the DC cable from power supply.Disconnect the flat cable.Remove the Tyrap which is fixed to the control module.Disconnect the RS232 cable from the modem if the Repeater is equipped with a modem.Dismount the battery backup board, if the battery backup module is installed.Take off the whole control module completely with mounting plate by unscrewing four tallowdrop screws M4.For mounting proceed in reverse order.Position of the control module in the Repeater is illustrated in REFthe following figure.figure 8-8 Position of control moduleControl module
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 54 10-March-008.9 Replacement of power suppliesFNote: Ensure that mains are disconnected.Open the Repeater to get access to the devices.Remove all connected cables from the clamps of the power supply. Try to loose the plug bymeans of a small screwdriver placed between the plug and socket.ONFuse 10A / 35Vfigure 8-9 Power supplyThe power supply is fixed to the Repeater housing by means of two special nuts M4. Afterloosen the screws the power supply can be removed. To open these screws a special key witha spherical head is required. Place a small screwdriver between the Repeater housing and thepower supply to loose the device.figure 8-10 Position of special-nut M4F Note: Don’t forget to put heat conducting paste on the mounting side forinstallation of a new power supply. Use the conducting paste, which isincluded in the spare parts kit.
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 55 10-March-008.10 Replacement of active combiner modulesThe active combiner modules are mounted on both sides of the Repeater.Disconnect all SMA connectors by means of a torque wrench.Unscrew two counter sunk screws M3x20mm.figure 8-11 Position of counter sunk screws on active combinerThe cabling of the active combiners depends on the configuration of the Repeater. For correctconnections see assembly guide for the channel modification kits.8.11 Replacement of feedforward amplifierThere is one feedforward amplifier mounted on each side of the Repeater.A special reset board is connected to the 15 pole SUB-D connector. (See figure 8-12 Positionof feedforward amplifier reset board)This reset board is part of the feedforward amplifier. A new feedforward amplifier will bedelivered with a premounted reset board.countersunkscrews
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 56 10-March-00figure 8-12 Position of feedforward amplifier reset boardRemove the ready made cable which is plugged to the 15 pole SUB-D connector of the resetboard. Unscrew the screw clip first.Unscrew the 6 socket head cap screws.The SMA connectors can be removed only after dismounting the amplifier.The position of the feedforward amplifiers is illustrated in figure 8-13 Position of feedforwardamplifiers.Reset board
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 57 10-March-00figure 8-13 Position of feedforward amplifiers
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 58 10-March-009 Appendices9.1 Repeater specificationsELECTRICAL SPECIFICATIONS MR301B PowerId-No: 150047Frequency range & bandwidth Up to 25 MHz in GSM900Frequency selectivity;Gain outside operating band ± 400 kHz: 50 dB max.; ± 600 kHz: 40 dB max.± 1000 kHz: 35 dB max.; ± 5000 kHz: 25 dB max.Gain (nominal) 85 dBGain adjust 0 to 30 dB in steps of 2 dBGain variation over frequ. and temp. ± 2.5 dB (± 3.5 dB at extreme temperature range)*Tolerance per step ± 0.5 dB from 0 to 6 dB attenuation± 2.0 dB from 8 to 30 dB attenuationDelay 6 µsec.max.Delayripple 150 ns30 dBm (@ 25° C)Output power ALC limit (test case)at 2 equal carriers +27 dBm / +27 dBm*ICP3 58 dBm @ max. gainALC limit tolerance of frequencyand temperature ±3 dBALC overload reaction time delay 3 msec. (others available on request)Noise figure 6 dB @ max. gain;8 dB @ 75 dB gain;Test coupler 30 dBReturn loss (@ 25° C amb. temp.) 15 dBPower Supply 230 Vac ± 15% / 40.-.65 Hz;Option:24 Vdc or 42 - 60 Vdc or 80 – 130 Vdc,115 Vac ± 15% / 40.-.65 Hz or 185 – 320 Vac /40 - 65 HzPower consumption (1 module) 160 WattsRemote control interface SM 2009Connectors 7/16 female; N as an optionEnvironmental and Safety see Environmental and Safety leaflet for MIKOMoutdoor cell enhancersBuilt in test equipment Current monitor • synthesizer lock monitor •temperature • ALC activeAlarm forwarding Potential free relay contact and automatic alarmcall via RS232 or PCMCIA interfaceControl functions Gain • Center frequency • ALC threshold* Normal temp.range  + 5° C to + 40°C   Extreme temp.range- 33° C to + 50° C
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 59 10-March-00ELECTRICAL SPECIFICATIONS MR401B PowerFrequency range Id-No:150043                                         150044                                         150045                                         150046UL:1710-1740 MHz; DL:1805-1835 MHzUL:1721,7-1751,7MHz; DL:1816,7-1846,7 MHzUL:1730-1760 MHz; DL:1825-1855 MHzUL:1751,5-1784,9 MHz; DL:1846,5-1879,9 MHzBandwith Up to 35 MHzFrequency selectivity;Gain outside operating band ± 400 kHz: 50 dB max.; ± 600 kHz: 40 dB max.± 1000 kHz: 35 dB max.; ± 5000 kHz: 25 dB max.Gain (nominal) 85 dBGain adjust 0 to 30 dB in steps of 2 dBGain variation over frequ. and temp. ± 2.5 dB (± 3.5 dB at extreme temperature range)*Tolerance per step ± 0.5 dB from 0 to 6 dB attenuation± 2.0 dB from 8 to 30 dB attenuationDelay 6 µsec.max.Delayripple 150 ns30 dBm (@ 25° C)Output power ALC limit (test case)at 2 equal carriers +27,5 dBm / +27,5 dBm*ICP3 57 dBm @ max. gainALC limit tolerance of frequencyand temperature ±3 dBALC overload reaction time delay 3 msec. (others available on request)Noise figure 6 dB @ max. gain;8 dB @ 75 dB gain;Test coupler 30 dBReturn loss (@ 25° C amb. temp.) 15 dBPower Supply 230 Vac ± 15% / 40.-.65 Hz;Option:24 Vdc or 42 - 60 Vdc or 80 – 130 Vdc,115 Vac ± 15% / 40.-.65 Hz or 185 – 320 Vac /40 - 65 HzPower consumption (1 module) 160 WattsRemote control interface SM 2009Connectors 7/16 female; N as an optionEnvironmental and Safety see Environmental and Safety leaflet for MIKOMoutdoor cell enhancersBuilt in test equipment Current monitor • synthesizer lock monitor •temperature • ALC activeAlarm forwarding Potential free relay contact and automatic alarmcall via RS232 or PCMCIA interfaceControl functions Gain • Center frequency • ALC threshold* Normal temp.range  + 5° C to + 40°C   Extreme temp.range- 33° C to + 50° C
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 60 10-March-00ELECTRICAL SPECIFICATIONS MR701B PowerFrequency range Id.No. UL frequency[MHz] DL frequency[MHz]148604 1850 – 1885 1930 – 1965151075 1865 – 1890 1945 - 1970148605 1875 – 1910 1955 - 1990Useable bandwidth 35 MHz (25 MHz in 151075) in the upper orlower PCS bandGain 90 dBGain variation overfrequency and temperature* ±2.5 dB (±3.5 dB at extreme temperatures)Gain adjust range 30 dB in 2 dB stepsGain adjust range tolerance ±0.5 dBReturn loss 15 dB @ 25°C ambient temperatureSpurious/intermodulation -13 dBm maxSpectral re-growth (CDMA only) -45 dBc (J-STD-008)Power supply 100-130 VAC / 40-60 HzOption: 15-24 VDC or 36-72 VDCOption: 220-250 VAC / 40-60 HzRF connector  7/16 femaleOption: N femaleEnvironmental and safety  See separate leaflet*: Normal temperature range +5° to +40°C; Extreme temperature range -33° to +50°C
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 61 10-March-00AVAILABLE POWER PER TECHNOLOGYCDMA TDMA GSMPout at 1 channel 37.0 dBm 40.0 dBm 40.0 dBmPout/channel at 2 channels 31.0 dBm 34.0 dBm 37.0 dBmPout/channel at 4 channels 28.0 dBm 29.0 dBm 33.0 dBmPout/channel at 8 channels 25.0 dBm 26.0 dBm 29.0 dBmALC threshold Adjustable
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 62 10-March-00BAND AND CHANNEL SPECIFICATIONSOption I(fixed bw) Option II(fixed bw) Option III(variable bw) ChannelCDMA       TDMA3 dB bandwidth 5 MHz 15 MHz 0.1 to 15MHz 1.23 MHz 30 kHzSlope 3 dB to 30 dB 1 MHz 2 MHz 2 MHz - -30 dB bandwith - - - fc ± 900kHz fc ±60 kHz50 dB bandwith - - - fc ± 1.5 MHz fc ± 120 kHzDelay 6 µs 3 µs 6 µs < 6 µs 20 µsDelay variation(typical) ±150 ns ±150 ns ±150 ns ±500 ns ±500 nsFar off selectivity 40 dB 40 dB 40 dB 60 dB 55 dBNF at Gmax 6 dB 6 dB 8 dB 6 dB 6 dBNF at Gmax-30 dB 12 dB 12 dB 13 dB 12 dB 12 dBOICP-3 at Gmax 59.0 dBm 59.0d Bm 59.0 dBm 59.0 dBm 59.0 dBmOICP-3 at Gmax -10 dB 58.6dBm58.5dBm58.5dBm58.5dBm59.0dBmOICP-3 at Gmax -20 dB 58.0dBm58.0dBm57.5dBm58.0dBm58.5dBmOICP-3 at Gmax -30 dB 56.0dBm56.0dBm53.0dBm55.0dBm57.0dBmOutput noisein band at Gmax -78 dBm/Hz -78 dBm/Hz -76 dBm/Hz - -Output noise out ofband at Gmax -98 dBm/Hz -98 dBm/Hz -96 dBm/Hz - -Power consumtionstandby/max power1 module (typ.cons)4 modules (typ.cons)130/220W160/250W130/220W160/250W145/220W180/270W130/210W160/240W130/210W160/240W
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 63 10-March-00ELECTRICAL SPECIFICATIONS MR801B PowerFrequency range Uplink 824-849 MHz; Downlink 869-894 MHzUseable bandwidth 25 MHz in the upper or lower AMPS 800 bandGain 90 dBGain variation overfrequency and temperature* ±2.5 dB (±3.5 dB at extreme temperatures)Gain adjust range 30 dB in 2 dB stepsGain adjust range tolerance ±0.5 dBReturn loss 15 dB @ 25°C ambient temperatureSpurious/intermodulation -13 dBm maxSpectral re-growth (CDMA only) -45 dBc (J-STD-008)Power supply 115 VAC ± 15% / 40 - 65 HzOption: 230 VAC ± 15% / 40 - 65 HzOption: 185 - 320 VAC / 40 - 65 HzOption: 24 VDCOption: 42 to 60 VDCRF connector  7/16 femaleOption: N femaleEnvironmental and safety  See separate leaflet*: Normal temperature range +5° to +40°C; Extreme temperature range -33° to +50°CAVAILABLE POWER PER TECHNOLOGYCDMA TDMA AnalogPout at 1 channel 37.0 dBm 40.0 dBm 40.0 dBmPout/channel at 2 channels 31.0 dBm 34.0 dBm 37.0 dBmPout/channel at 4 channels 28.0 dBm 29.0 dBm 33.0 dBmPout/channel at 8 channels 25.0 dBm 26.0 dBm 29.0 dBmALC threshold Adjustable
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 64 10-March-00BAND AND CHANNEL SPECIFICATIONSVariable Bandwidth ChannelCDMA TDMA3 dB bandwidth 0.1 to 15.0 MHz 1.23 MHz 30 kHzSlope 3 dB to 30 dB 2 MHz - -30 dB bandwith -fc ± 900 kHz fc ± 60 kHz50 dB bandwith -fc ± 1.5 MHz fc ± 120 kHzDelay 6 µs < 6 µs 20 µsDelay variation (typical) ±150 ns ±500 ns ±500 nsFar off selectivity 40 dB 60 dB 55 dBNF at Gmax 8 dB 6 dB 6 dBNF at Gmax-30 dB 13 dB 12 dB 12 dBOICP-3 at Gmax 59.0 dBm 59.0 dBm 59.0 dBmOICP-3 at Gmax -10 dB 58.5 dBm 58.5 dBm 59.0 dBmOICP-3 at Gmax -20 dB 57.5 dBm 58.0 dBm 58.5 dBmOICP-3 at Gmax -30 dB 53.0 dBm 55.0 dBm 57.0 dBmOutput noisein band at Gmax-76 dBm/Hz - -Output noise out of bandat Gmax -96 dBm/Hz - -Power consumtion(standby/max power)1 module (typ.cons)4 modules (typ.cons)145/220 W180/270 W130/210 W160/240 W130/210 W160/240 W
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 65 10-March-00ELECTRICAL SPECIFICATIONS MR801Bi PowerFrequency range Uplink 806-824 MHz; Downlink 851-869 MHzUseable bandwidth 18 MHz in the upper or lower iDEN bandGain 90 dBGain variation overfrequency and temperature* ± 2.5 dB (± 3.5 dB at extreme temperatures)Gain adjust range 30 dB in 2 dB stepsGain adjust range tolerance ± 0.5 dBReturn loss 15 dB @ 25°C ambient temperatureSpurious/intermodulation -13 dBm max.Power supply 100 to 130 VAC / 40 - 60 HzOption: 220 to 250 VAC / 40 - 60 HzOption: 185 to 320Vac, 40 - 65HzOption: 24 VDCOption: ± 42 to ± 60VDCOption: ± 80 to ± 130VDCRF connector  7/16 femaleOption: N femaleEnvironmental and safety  See separate leaflet*: Normal temperature range +5° to +40°C; Extreme temperature range -33° to +50°CAVAILABLE POWER PER TECHNOLOGYiDEN AnalogPout at 1 channel 37.0 dBm 40.0 dBmPout/channel at 2 channels 31.0 dBm 37.0 dBmPout/channel at 4 channels 28.0 dBm 33.0 dBmPout/channel at 8 channels 25.0 dBm 29.0 dBmALC threshold Adjustable
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 66 10-March-00BAND AND CHANNEL SPECIFICATIONSVariable Bandwidth Channel Selective3 dB bandwidth 0.1* to 15.0 MHz 25 kHzSlope 3 dB to 30 dB 2 MHz -30 dB bandwith -fc ± 60 kHz50 dB bandwith -fc ± 120 kHzDelay 6 µs 20 µsDelay variation (typical) ± 150 ns ± 500 nsFar off selectivity 40 dB 50 dBNF at Gmax 8 dB 6 dBNF at Gmax-30 dB 13 dB 12 dBOICP-3 at Gmax 48 dBm 48 dBmOICP-3 at Gmax -10 dB 48 dBm 48 dBmOICP-3 at Gmax -20 dB 47 dBm 47 dBmOICP-3 at Gmax -30 dB 45 dBm 45 dBmOutput noise in band at Gmax -81 dBm/Hz -Output noise out of band at Gmax -101 dBm/Hz -Power consumtion(standby/max power)1 module (typ.cons)4 modules (typ.cons)155/220 W200/265 W150/210 W175/240 W1.5 dB gain degradation at 100 kHz
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 67 10-March-00MECHANICAL SPECIFICATIONS MRx01B PowerThe MRx01B Power is available in the G-cabinetMax. Height x Width x Depth: 21.1 x 18.2 x 7.9 inches535 x 462.5 x 200 mmVolume: approximately 45 litresWeight: approximately 103 lbs (47 kg per unit in standardconfiguration)The illustration of chapter provides the dimensions and the view of the layout.ENVIRONMENTAL AND SAFETY MRx01B PowerFor detailed information refer to the environmental and safety specification leaflet forMIKOM indoor / outdoor cell enhancers, related to ETS 300019 (European Tele-communication Standard).Operating temperature (normal temperature range): + 5° C ... + 40° C (extreme temperature range): - 33° C ... + 50° CHumidity: + 30° C/ 93 %All data is subject to change without notice !
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 68 10-March-009.2 Spare parts lists for MRx01B PowerThe following list contains all parts available for the MRx01B Power. The configuration ofthe delivered unit meets the requirements of the customer and can differ depending on thestate of delivery.9.2.1 Spare parts list for MR301B PowerDesignation Id.-No.:MR301B Power 150047Assembly drawing 149952Assembly drawing (RF-cable plan) 150563Mounting material 150521Duplexer UL Input 150302Duplexer DL Input 150303Bas.Mod.Fix.BW 25,0 MHz 150125Bas.Mod.Fix.BW 15,0 MHz 151347Bas.Mod.Fix.BW 12,5 MHz 149642Bas.Mod.Fix.BW 8,2 MHz 149187Bas.Mod.Fix.BW 6,0 MHz 149178Bas.Mod.Var.BW 25,0 MHz 150135Bas.Mod.Var.BW 10,0 MHz 148281Ext.Mod.Var.BW 10,0 MHz 150136Power Amplifierkit 4W 151647Power Supply, GER plug 138305Power Supply, UK plug 142832Power Supply, no plug 148812Power Supply, no plug 144306Power Supply, USA plug 141230Power Supply, no plug 145524Power Supply, no plug 144946Power Supply, no plug 145504M1 Kit 900 MHz 146999VSWR Kit GSM + EGSM 143437Ext. Alarms SW-Option 145067Battery Backup Module 143052RF Gland / SMA to N 150615Adapter 7 / 16 male - N female 112425SW MOB100 V1.10 143055SW REP1009 V1.11 147127Modification Kit 1 channel band selective 149917Modification Kit 2 channels band selective 149918Modification Kit 3 channels band selective 150529Modification Kit 4 channels band selective 149920
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 69 10-March-00Main Board 12V version 149780Main Board 12V version 149779Control Unit SM2009 143051Wall mounting kit 146179Sparepart kit 146200Termination Resistor 33167Ready-made cable AC 143032Manual MRx01B Power 151775Manual REP1009V1.xx 148964Additional information 148222Assembly guide MRx01B Power 151045
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 70 10-March-009.2.2 Spare parts list for MR401B PowerDesignation Id.-No.:MR401B Power 150043 150044 150045 150046Assembly drawing 149952Assembly drawing (RF-cable plan) 150563Mounting material 150521Duplexer UL Input 150304 150306 150308 150300Duplexer DL Input 150305 150307 150309 150301Bas.Mod.Fix.BW 25,0 MHz 150141Power Amplifierkit 4W 151648Power Supply, GER plug 138305Power Supply, UK plug 142832Power Supply, no plug 148812Power Supply, no plug 144306Power Supply, USA plug 141230Power Supply, no plug 145524Power Supply, no plug 144946Power Supply, no plug 145504Ext. Alarms SW-Option 145067Battery Backup Module 143052RF Gland / SMA to N 150615Adapter 7 / 16 male - N female 112425SW MOB100 V1.10 143055SW REP1009 V1.11 147127Modification Kit 1 channel band selective 149917Modification Kit 2 channels band selective 149918Modification Kit 3 channels band selective 149919Modification Kit 4 channels band selective 149920Main Board 12V version 149780Main Board 12V version 149779Control Unit SM2009 143051Wall mounting kit 146179Sparepart kit 146200Termination Resistor 33167Ready-made cable AC 143032Manual MRx01B Power 151775Manual REP1009V1.xx 148964Assembly guide MRx01B Power 151045
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 71 10-March-009.2.3 Spare parts list for MR701B PowerDesignation Id.-No.:MR701B Power 148604 148605 151075Assembly drawing 149952Assembly drawing RF 151102Assembly drawing (RF-cable plan) 150563Mounting material 150521PCS-Duplexer UL Input 144382 144384 151072PCS-Duplexer DL Input 144381 144383 151073Active Combiner UL 148686Active Combiner DL 148685Bas.Mod.Fix.BW 15,0 MHz 148717Bas.Mod.Fix.BW 5,0 MHz 148716Bas.Mod.Var.BW 15,0 MHz 151463Ext.Mod.Fix.BW 15,0 MHz 151464Basic Module 148702Extension Module 148705Basic Module TDMA 148703Extension Module TDMA 148706Basic Module CDMA 148704Extension Module CDMA 148707Feedforward Amplifier UL 148627Feedforward Amplifier DL 148628Power Supply, GER plug 138305Power Supply, UK plug 142832Power Supply, no plug 148812Power Supply, no plug 144306Power Supply, USA plug 141230Power Supply, no plug 145524Power Supply, no plug 144946Power Supply, no plug 145504Mobile kit PCS 150405Ext. Alarms SW-Option 147710Battery Backup Module 143052Battery Backup Module, Dummy without Accu 143750RF Gland / SMA to N 150615Adapter 7 / 16 male - N female 112425SW MOB100 V1.10 143055SW REP1007 V1.12 145488SW REP1009 V1.11 147127Modification Kit 1 channel band selective 149917Modification Kit 2 channels band selective 149918Modification Kit 3 channels band selective 149919
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 72 10-March-00Modification Kit 4 channels band selective 149920Modification kit TDMA for 1+2 channel 151135Modification kit TDMA for 3+4 channel 151136Main Board 26V version 149778Main Board 26V version 149777Control Unit SM2009 143051Wall mounting kit 146179Sparepart kit 146200Termination Resistor 33167Ready-made cable DC 149648Ready-made cable DC act. Com. 150753Ready-made cable AC 152024Manual MRx01B Power 151775Manual REP1007V1.11 145956Manual REP1009V1.xx 148964Assembly guide MRx01B Power 151045
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 73 10-March-009.2.4 Spare parts list for MR801B Power and MR801Bi PowerDesignation Id.-No.:MR801B Power / MR801Bi Power 148613 151270Assembly drawing 149952Assembly drawing RF 151102Assembly drawing (RF-cable plan) 150563Mounting material 150521Duplexer UL Input 148334 148335Duplexer DL Input 148333 148336Active Combiner UL 148688 148960Active Combiner DL 148687 148959Bas.Mod.Var.BW 15,0 MHz 148715 150150Ext.Mod.Var.BW 15,0 MHz 148944 150151Basic Module TDMA 148712Extension Module TDMA 148710Basic Module CDMA 148713Extension Module CDMA 148709Basic Module CDMA f1/f2 152228Basic Module 150152Extension Module 150153Feedforward Amplifier UL 148629 151232Feedforward Amplifier DL 148630 151233Power Supply, GER plug 138305Power Supply, UK plug 142832Power Supply, no plug 148812Power Supply, no plug 144306Power Supply, USA plug 141230Power Supply, no plug 145524Power Supply, no plug 144946Power Supply, no plug 145504Mobile kit PCS, without mobile 150404Mobile kit PCS, with mobile 150407Ext. Alarms SW-Option 147710Battery Backup Module 143052Battery Backup Module, Dummy without Accu 143750RF Gland / SMA to N 150615Adapter 7 / 16 male - N female 112425SW MOB100 V1.10 143055SW REP1007 V1.12 145488SW REP1009 V1.11 147127Modification Kit 1 channel band selective 149917Modification Kit 2 channels band selective 149918Modification Kit 3 channels band selective 150529
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 74 10-March-00Modification Kit 4 channels band selective 149920Modification kit TDMA for 1+2 channel 151135Modification kit TDMA for 3+4 channel 151671Main Board 26V version 149778Main Board 26V version 149777Control Unit SM2009 143051Wall mounting kit 146179Sparepart kit 146200Termination Resistor 33167Ready-made cable DC 149648Ready-made cable DC act. Com. 150753Ready-made cable AC 152024Manual MRx01B Power 151775Manual REP1007V1.11 145956Manual REP1009V1.xx 148964Assembly guide MRx01B Power 151045
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 75 10-March-009.3 Installation drawing of the Repeaterfigure 9-1 Installation drawing of the Repeater
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 76 10-March-009.4 Top view of the Repeater (left side , exemplary configuration)figure 9-2 Top view of the Repeater (left side, exemplary configuration)
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 77 10-March-009.5 Top view of the Repeater (right side, exemplary configuration)figure 9-3 Top view of the Repeater (right side, exemplary configuration)
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 78 10-March-009.6 One channel configuration – cabling and block diagramfigure 9-4 Cabling of one channel Repeater
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 79 10-March-00figure 9-5 Block diagram of one channel Repeater
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 80 10-March-0010 IndexAAbbreviations  8Active combiner  22, 56Alarm monitoring  46AlarmsAcknowledgement of  28External alarms  30Handling of  28Indication of  26List of all alarms  27ALC  26Antenna connectors  38, 39Antenna isolation  40AT commands  45BBattery backup  33BITE  26  46CChannelSetting via PC  43Clamping profile  49Connector types7/16 female  39N female  32Contents of delivery  8Control module  17Configuration  19conversion module  51DDIP-Switch  43DIP-Switch settings  20  51Duplexer  14, 21, 51EEEPROM  17Environmental and safety  68FFeedforward amplifier  23  25GGainLocal settings  25, 41Setting via PC  43Grounding  37HHealth and safety warnings  9II²C-Bus  17Ident numbers  69, 71, 72, 74InstallationElectrical  38Mechanical  35Interfaces  17RS232  17International sales offices  11LLEDs  26Local settings  41MMaintenance  48Measurements ofVSWR signals  30Modem  44Mother board  15Mounting brackets  36OOptional modules  30Output DLexternal  32
User’s manual for Repeater MRx01B PowerM0079A1A.doc Id.-No. 151775 Page 81 10-March-00PPower supply  23Replacement of  55RRAM / RTC battery  50Remote control  25Rotary switchTo set the gain  42SSetting of operational parameters  40Setting to work  40Severity levels  29TTest probes  22Trouble shooting  46