Allterco Robotics SSWTHLIM MyKi Care - Thermometer User Manual MCT 1 0

Allterco Robotics MyKi Care - Thermometer MCT 1 0

User Manual

MyKiCareThermometer(MCT1.0)   USERMANUALAlltercoRoboticsLTD.1404Sofia,Bulgariaphone+35929571247www.MyKi.Caresupport@myki.carePrecautionsforuseAnyformofmodificationtothisdeviceisforbidden;Don’tusethedevicetogetherwithMRIorCTequipment;Explosiondanger:don’tusethedeviceinflammableanestheticgas;Don’tsqueezethedevice.Ifthehousingisbroken,pleasestopusingthedevice.Pleasecheckdeviceregularlytomakesurethatitmakescontactwithskintightly;otherwisethedatamaybeinaccurate.Thedeviceisforindooruseonly;Pleasepayattentiontotheoperationtemperatureandhumidity.Usingthethermometerinaconditionthatdoesnotsatisfytherequirementmayleadtomeasurementerror;Theeffectivewirelesstransmissiondistanceis10minabarrier‐freeenvironment.Thethermometermaynotworkifattemptingtouseatgreaterdistances.Pleaseusethisproductwithineffectivewirelesstransmissiondistance;Muscleandfataffectwirelesstransmission,sothetransmissionrangemaybeweakenedwhenobeseadultorchildusesthedevice.Magneticandelectricalfieldsarecapableofinterferingwiththeproperperformanceofthethermometer.ForthisreasonmakesurethatallexternalequipmentoperatedinthevicinityofthethermometercomplieswiththerelevantEMCrequirement.Mobilephone,X‐rayequipmentorMRIdevicesareapossiblesourceofinterferenceastheymayemithigherlevelsofelectromagneticradiation.Thethermometerisnotsterile;Doctorshoulddiagnoseclinicalsymptoms,onlywithusingthethermometerassubsidiary;Thisproducthasbeencalibrated.Nootherroutinemaintenanceandcalibrationisneededinadditiontothereplacementbattery;Ifthesystemupgrade,pleaseupdatetheprogram;Itisveryunlikelythatthethermometerisnotcompatiblewiththemobileapponyourmobiledevice.Pleasecontactusifyouexperiencethisproblem;Ifyouhavequestionsconcerningsettingup,using,maintenanceofthethermometeroranyunexpectedevents,pleasecontactMyKiCaresupportat:support@myki.careWhenthepatientistheoperator,pleaseuseandmaintainthethermometeraccordingtothismanual.Werecommendtheuserstousetheoriginalmanufacturedadhesivepads.Togetbestreadingonthermometeruseinacoolenvironment.Ifyoufeelunwell(uncomfortableorallergic)whenusingtheadhesivepad,pleasediscardandstopusingadhesivepadandfollowdoctor’sadvice.Whenmeasuringforalongtime,pleasecheckwhetherthereanallergicreactionwithskin.Ifthereisanallergicreaction,youshouldstopusingthethermometerimmediately.Pleasedonotre‐pastetheadhesivepadifitappearsused,Anewadhesivepadisrequired.Skinpreparationinadvanceisrequiredwhenwornbyadult.Pleasemakesurethatskiniscleananddry.Pleasecleanthesurfaceofthethermometerwith75%concentratedmedicalalcoholbeforeandafterusingit.Youshouldcleantheskincontactedthe
MyKiCareThermometer(MCT1.0)   USERMANUALAlltercoRoboticsLTD.1404Sofia,Bulgariaphone+35929571247www.MyKi.Caresupport@myki.carethermometerwithmedicinalalcoholaftertakingoffthedevice.Thematerialthatcontactsskinisnontoxic,nonirritatingandwillnotcauseallergyoranyothersideeffect.OnemayexperienceanallergicreactionorpossibleothersideeffectIfpetsorpeststouchthedevice.Pleasecleanthesurfaceofthedevicewith75%concentratedmedicalalcoholbeforeusingit.Ifchildrentamperorplaywiththedevice,thismaydamagethetemperaturemeasuringprobeandaffectthemeasureaccuracy.Thethermometerstartsupwhenyoushakeitintensiveduring3seconds.Whenisstrarttheredlightisblinking5times.Ifyoushakeitduringtheworktheredlightisblinkfor3times.Thermometershutsdownautomaticallywhenthetemperatureisunder35degreeandnotshackedfor5min.Thethermometersendstemperaturetothedeviceevery8‐12seconds.Thisproducthasoverrunpromptedfunction,anduserscansetthealarmlimitthemselves.ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttothefollowingtwoconditions:(1)Thisdevicemaynotcauseharmfulinterference;(2)Thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperation.Theuseriscautionedthatchangesormodificationsnotexpresslyapprovedbythepartyresponsibleforcompliancecouldvoidtheuser'sauthoritytooperatetheequipmentFCCSTATEMENT:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates,usesandcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipmentoffandon,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthefollowingmeasures:‐‐Reorientorrelocatethereceivingantenna.‐‐Increasetheseparationbetweentheequipmentandreceiver.‐‐Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected.‐‐Consultthedealeroranexperiencedradio/TVtechnicianforhelp.IntendedUseThedeviceisintendedtobeusedformeasuringandmonitoringhumantemperaturecontinuously.Itcanstoreandmanagethetemperaturedata.Itcanbeusedtomeasurearmpittemperaturefortheadult,pediatricandneonatepeople.Thedeviceisnotwaterproofandcannotusedtomeasureliquidtemperature.DownloadAndInstallTheSoftwareTheThermometeriscompatiblewithiOS7+andAndroid5+devices.TouseitopentheAppstoreforiOSorGooglePlayforAndroidanddownloadtheapplicationMyKiCare.OperationInstructions1. OpenMyKiCareapplicationandcreateaccount.
MyKiCareThermometer(MCT1.0)   USERMANUALAlltercoRoboticsLTD.1404Sofia,Bulgariaphone+35929571247www.MyKi.Caresupport@myki.care2. Logininyouraccountandinputpatientdata.3. ShaketheThermometerfor3seconds,duringtheredlightstartblinkingfor5seconds.4. PressontheIDoftheThermometer5. PlacetheThermometerunderthearmwithmetalparttothebody.6. Puttheadhesivepadcarefully.Ifyouneedtore‐placechangetheadhesivepad.Changeadhesivepadevery2hoursduringthedayand6‐8hoursduringthenight.
MyKiCareThermometer(MCT1.0)   USERMANUALAlltercoRoboticsLTD.1404Sofia,Bulgariaphone+35929571247www.MyKi.Caresupport@myki.careThermometerneed12‐15mintomeasureandshowthebodytemperature.Youcanusethermometerformultiplepatientsinoneapplication.Toaddnewpatientjustslidelefttorightandfollowthescreeninstruction.Youcanwatchthethermometerdatafromunlimiteddevicesatsametime.Forthat,alldevicesshouldsharesameaccount.Onlyoneofalldevicesshouldbeupto10meterstothethermometer.Alldataautomaticallyuploadtothecloudandallotherdevicescanseewhenevertheyare.Youshouldtohaveinternetconnectiontoalldevices.Setcorrectalarmsettingbaseofyourrequirements.Thealarmmaybenotworkifyouyourmobilephonedonothaveinternet,notificationsisforbidden,yourdeviceisinDNDmodeornotificationservicesistemporaryinaccessible.
MyKiCareThermometer(MCT1.0)   USERMANUALAlltercoRoboticsLTD.1404Sofia,Bulgariaphone+35929571247www.MyKi.Caresupport@myki.careProductspecifications:Productname: MyKiCareThermometerProductmodel: MCT1.0Weightwithoutbattery:MeasurespecificationsMeasurescope34.00Ԩ~45.00Ԩ(93.00Ԭ~113.00Ԭ)Measureaccuracy+/‐0.1C(0.18F)TemperatureunitCorFUpdatetimeEvery8‐12secondsLight BliningwhenshakedSoftwareplatformiOS7+versionAndroid5+versionBatteryTypeCR2025,3V/163mAHbuttonbatteryWorktime7days/8hperdayEnvironmentspecificationsTemperatureOperating:5℃~+45℃;Transportationandstorage:‐20Ԩ~+55Ԩ.HumidityOperating:25%~95%(noncondensing)Transportationandstorage:25%~95%(noncondensing)AtmosphericpressureOperating:700hPa~1060hPa;Transportationandstorage:500hPa~1060hPa.Possibleproblemsandsolutions:Symptom SolutionDevicenotwake‐upwhenIshakeit.Redlightdonotappear.Checkthebattery.Carefullyopenthedeviceandreplacethebatterywithnewone.Temperatureisnotcorrectafter20minCheckthedeviceposition.Mustbeunderarmwithmetalcapconnectedtothebody.Replacetheadhestivepad.ThermometerdonotconnecttothemobiledeviceForchildrenmobilephoneshouldmeunder10meterfromthethermometer.Foradults,mobilephoneshouldbeunder2meterstothethermometer.Check–areyourBluetoothisactivated.Cannotremembermuaccountdetails.Createnewaccountandaddthemormtertoitorcontactwith:support@myki.careGuidanceandmanufacture’sdeclarationofEMCThedeviceisintendedforuseintheelectromagneticenvironmentspecifiedbelow.Thecustomeroftheuserofthedeviceshouldassurethatitisusedinsuchanenvironment.EmissiontestComplianceRFemissionsCISPR11Group1RFemissionCISPR11ClassBHarmonicemissionsIEC61000‐3‐2Notapplicable(Batteryoperateddevice)Voltagefluctuations/flickeremissionsIEC61000‐3‐3Notapplicable(Batteryoperateddevice)SAR…………….
MyKiCareThermometer(MCT1.0)   USERMANUALAlltercoRoboticsLTD.1404Sofia,Bulgariaphone+35929571247www.MyKi.Caresupport@myki.careOperation Frequency:  Bluetooth: 2402-2480MHz, 40 channels for BLE Max. RF output power: Bluetooth: -0.70dBm Hardware Version: MT01CY Software Version: FW-MT01 Environmental Conditions: Working Temperature:  5 ~ 45℃  Working humidity:  25~95%RH Bluetooth can be used in Europe without restriction. Hereby, Allterco Robotics, declares that this MyKi Care - Thermometer / MCT 1.0 is In compliance with the essential Requirements and other relevant provisions of RE Directive 2014/53/EU.

Navigation menu