Alcatel Canada 39T28A03A22A Alcatel 7390 LMDS Multiservice Broadband Wireless User Manual 3cc12426aaaaTQbja01

Alcatel Canada Inc Alcatel 7390 LMDS Multiservice Broadband Wireless 3cc12426aaaaTQbja01

Base Sation User Manual 14 of 14

3CC12426AAAA TQ BJA 01 Issue 01 - April 2001 - Draft 04 331/346332– Press "Finish".– Now you are ready to use Python for the MIB migration.A.3.4 – LT configuration file modificationIf the MIB migration CD content has not been copied in the default directory ("C:"), you need to edit theLT configuration file (C:\ProgramFiles\7390LT\Craft.ini) and modify the following parameter:MIB_MIGRATION_SCRIPT_PATH="C:\mibconv"If "Python" has not been installed in the default directory, you need to edit the LT configuration file(C:\ProgramFiles\7390LT\Craft.ini) and modify the following parameter:MIB_MIGRATION_PYTHON_EXE="C:\Program Files\Python\Python.exe"
332/346 Issue 01 - April 2001 - Draft 04 3CC12426AAAA TQ BJA 01332PAGE INTENTIONALLY LEFT BLANK
3CC12426AAAA TQ BJA 01 Issue 01 - April 2001 - Draft 04 333/346336Appendix 4 – Mounting coaxial connectorMounting on cable LDF4Alcatel Code: 77096434
334/346 Issue 01 - April 2001 - Draft 04 3CC12426AAAA TQ BJA 01336
3CC12426AAAA TQ BJA 01 Issue 01 - April 2001 - Draft 04 335/346336
336/346 Issue 01 - April 2001 - Draft 04 3CC12426AAAA TQ BJA 01336PAGE INTENTIONALLY LEFT BLANK
3CC12426AAAA TQ BJA 01 Issue 01 - April 2001 - Draft 04 337/346338Appendix 5 – Correspondence between commercialcodes and industrial codes relating to the BS   Installation item Commercial code Industrial code CommentsDBS basic configurationRack 22 U 9900CAB001 3CC 10067 AAxxDBS installation itemsPower S. cable POWCAB0001 77096649 15 m 3x10 mm2Distributor Panel16x2 Mbits/s9900XXI416  3CC 08061 AAxx2x3CC 11236 AAxx75 Ohms1.6 / 5.69900XXI416 3CC 08061 ABxx2x3CC 11237 AAxx 75 Ohms / BNC9900XXI416 3CC 10316 ABxx2x3CC 11238 AAxx 120 Ohms - EMCRBS installation itemsGrounding cable(20 meters) 9900XXC502 3CC 08166 AAxx(per meter)Consummable 9900UXT002 3CC 06503 AAxx50 Ohms coaxial cable(50 meters) 9900UXI202 50 m of1AC 001100022Coaxial connector 9900UXI203 2 x 1AB 095530021 (x2)Grounding kit   9900UXI204 1AB 128500002114 mm tube (2 meters) SUPOUTD001 3CC 04658 AExx2 pole-mounting fastening kit(1+1) 9900UXI104 3CC 11681 AAxxSelf supporting mast 114 mm (1.5 meter) SUPMAST001 3CC 05148 AAxxCable tray cablofil (6 m) INFRA00003 3CC 07580 AAxxCable tray PVC (4 m)   INFRA00004 3CC 06511 AAxxCable tray CES (12 m)   INFRA00005 3CC 06759 AAxxGaine Capri (12 m)   INFRA00006 3CC 06512 AAxxCable LDF 4-50    9900WVG001 77 096 434 50 Ohms (10 m)N Connector kit   9900UXX022 77 096 433 N male right,1 for each cable LDF4-50
338/346 Issue 01 - April 2001 - Draft 04 3CC12426AAAA TQ BJA 01338Installation item Commercial code Industrial code CommentsJumper 9900WVG004 3CC 09514 AAAA  N male bented/Nmale right (3 m)Jumper   9900WVG005 3CC 09514 ABAA N female bented/N male right (3 m)RBS installation toolsTool kit 9900UXT103 3CC 08409 AAxxPC 9900LTLaptop PC French(incl. Ethernet module) 9900LTH001 3CC 10939 AAxxDesktop PC French (incl. Ethernet module) 9900LTH002 3CC 10626 AAxxLaptop PC English(incl. Ethernet module) 9900LTH001 3CC 11200 AAxxDesktop PC English(incl. Ethernet module) 9900LTH002 3CC 11201 AAxxNFS Server softwareLT application software CDROMEmbedded softwarepackage CDROMCDROM User Manual2.1, 2.2a, 2.2b9900LTS0011AH 00845 AAxx3CC 12468 AAxx3CC 12464 AAxx3CC 12144 AAxx
3CC12426AAAA TQ BJA 01 Issue 01 - April 2001 - Draft 04 339/346344Appendix 6 – Error messages and corrective actionsThe tables below list the main error messages when operating 7390 LT.The purpose of this chapter is to give, for each message, an additional information and to suggest oneor more corrective actions. However, various causes may originate malfunction and it may occur andderive one from another; thus the corrective action suggested may not be the only solution. Furthermore,the operator is, in some cases, free to take initiative to solve the problem, considering thattroubleshooting should take into account the configuration context.Whenever the malfunction is not fixed, please contact TAC (see page 3).A.6.1 – Error messages for 7390LT softwareA.6.2 – NT management error messagesMessage Definition Corrective actionsError in craft.ini file 7390LT software can not be laun-ched, its configuration file contains errors. The errored parameter name is displayed on the screen.The solution requires an intervention at the craft.ini file level. Only qualified personnel should intervene.For this purpose, please contact the TAC (see page 3).An error occured when opening the Data Base7390LT can not retrieve its data base files.Make sure the .mdb files are ins-talled in the database directory. If not, install again 7390LT (see Appendix A.2).Info model version com-patibleWhen connecting to a BS, the data base versions differ on agent and manager side: e.g.: the 7390LT is version 2.1 whereas the base sta-tion is version 2.0.Perform download of the appro-priate software version (see § 7.3.10).Message Definition Corrective actionsError when declaring the new NTDeclaring the new NT is denied. Make sure that:. the serial number is valid, (preceded by 4 dashes then CU follow-up by 1 dashe). the associated AMD board configuration is fully carried out.An NT with this index already existsThe NT identification number ente-red is already assigned to another NT.Assign a free number. Contact the scheduler.Waiting NT characteris-ticsThis message displays a system status and shows no anomaly. At the end of the NT creation, the sys-tem is waiting for information about it.Please, wait until the relevant information is transmitted.Error at the reception of SNMP message: Error when destroying the NT.The NT destroy control is denied, one of its ports being used by an IP cross-connection or leased lines (LL).Delete all IP or LL cross-connec-tions that use the NT ports before initiating the NT destroy control.
340/346 Issue 01 - April 2001 - Draft 04 3CC12426AAAA TQ BJA 01344A.6.3 – Error messages for communication between BS and 7390LTA.6.4 – Error message linked with client servicesA.6.4.1 – Error messages linked with E1 leased linesMessage Definition Corrective actionsAn error occured at the BS connection: Error when declaring the managerDeclaring the manager is denied. Make sure that no other LT session is active (see section 4.3.1).Connection failure: NE not foundThe communication establishment with BS at the IP level failed.. Check the IP level link with BS.. Check if the cable fits to your network configuration (crossed or no Pc-DBS ethernet cable).TIMEOUT on request No answer to SNMP request when timeout expired. One of the causes may be a communication interruption between the BS and the PC on which 7390 LT is installed.This interruption may be brief. If this problem is persistent, the message "The connection with the NE has been lost. The Craft will be re-initialized" comes to confirm a permanent cut.If the interruption is brief, the malfunction will disappear without any intervention being required. In case of a permanent cut, refer to the following mes-sage: "The connection with the NE has been lost. The Craft will be re-initialized".The connection with the NE has been lost. The Craft will be re-initializedPermanent cut of communication between the BS and the PC on which 7390LT is installed.Start again the 7390LT. If the problem persists, check all ele-ments involved in the connection between BS and PC.Message Definition Corrective actionsAlready involved in ano-ther cross-connectionCreation control for a leased line denied, assigned TSs being already used by other cross-connections.Try to create another leased line using available TSs.A cross-connection exists on the TNT port N°xxxCreation control for a leased line denied, another line using the port N°xxx of the TNT.Try to create another leased line using available TNT port (see the cross-connections list in section 4.11.4.1).A cross-connection exists on the NT port N°xxxCreation control for a leased line denied, another line using the port N°xxx of the NT.Try to create another leased line using available NT port (see the cross-connections list in section 4.11.4.1).Error when creating the cross-connection: not enough downstream resources allocated.Creation control for a leased line denied because of a lack of resour-ces for the upstream communica-tion.Check the upstream channel traffic using the supervision (see section 4.7).Error when creating the cross-connection: not enough upstream resour-ces allocated.Creation control for a leased line denied because of a lack of resour-ces for the downstream communi-cation.Check the allocation with the scheduler.
3CC12426AAAA TQ BJA 01 Issue 01 - April 2001 - Draft 04 341/346344A.6.4.2 – Error messages linked with IP "cross-connection"A.6.4.3 – Error messages linked with circuit emulationThe selected ports must be configured identically before selecting a TS (Time Slot).Creation control for a leased line denied because the selected ports have a different configuration.Check the configuration of the NT and TNT ports (see section 4.11.1.3). Perform any relevant modification.E1 slots must be conse-cutiveCreation control for a leased line denied because the time slots num-bers are not consecutive.Assign contiguous numbers to time slots (TS).Time out on creating the leased lineCreating the leased line did not suc-ceed at the time out.Carry out data downloading (see section 4.4.1).Time out on deleting the selected leased lineDeleting the selected leased line did not succeed at the time out.Carry out data downloading (see section 4.4.1).Error when deleting the Cross-connection: the cross-connection on leased line is not lockedCreation control for a cross-connec-tion on leased line denied because it is liable to route traffic.Lock the cross-connection before triggering the deletion control (see § 4.11.4.5).Message Definition Corrective actionsError when creating the Cross-connection:Down Resource Pro-blem.Creation control for an IP cross-con-nection denied because of a lack of upstream resources.Check upstream traffic using the supervision (see section 4.7).Error when creating the Cross-connection:Up Resource Problem.Creation control for an IP cross-con-nection denied because of a lack of down-stream resources.Check allocation with the scheduler.Error when creating the Cross-connection: Ether-net Port already involved.Creation control for an IP cross-con-nection denied because the NT Ethernet port is already used.see the IP cross-connection list that displays the used ports (see section 4.12.2.1). Carry out any relevant modification.Error when creating the Cross-connection:ATM Port Value error.Creation control for an IP cross-con-nection denied because one of the following values is false: either "VCL Vpi" or "VCL Vci".Assign a value within the range of the possible values (see section 4.12.2.3).Error creating the cross-co : ATM Medium type is not configuredConfigure the ATM medium type (see section 4.9.1).Message Definition Corrective actionsCES link configuration failedCreation control for an CES denied because the TNT port is unlocked.lock TNT port (see section 4.11.1.4)Message Definition Corrective actions
342/346 Issue 01 - April 2001 - Draft 04 3CC12426AAAA TQ BJA 01344A.6.5 – Download error messagesA.6.6 – Error message at backup / restoreA.6.7 – Error messages for radio managementA.6.7.1 – Error messages linked to the radio configurationA.6.7.2 – Radio Resources Manager (RRM)Message Definition Corrective actionsSoftware download done with problems detected.An error occurred during data down-load.. Check the NFS server status is operational,. Chek hardware description for the BS boards.. Check the exported directory has been added to the omni-NFS server during a session with adminis-trator rights.Package commit done with problems.An error occurred during referen-cing.Check for any current board alarms. If so, rectify the problem in all cases (whether or not the card presented an alarm) carry out again a complete download.Message Definition Corrective actionsError when transfering the sRam FileNFS server problem (directory not recognized by the server)Export the directory in R/W to the NFS server.Message Definition Corrective actionsError when setting the radiolink characteristicsThe modification of the radio link characteristics displayed cannot be taken into account.Before modifying the bandwidth, suppress the NTs linked to this radio link (see 4.6.3)Message Definition Corrective actionsBad static Value down-streamInconsistency between the services already created and the modified static zone in the downstream- Cancel the modification- Update the static zone with avalue compatible with the staticservices already createdBad static Value ups-treamInconsistency between the services already created and the modified static zone in the upstream (x from 1 to 4)- Cancel the modification- Update the static zone with avalue compatible with the staticservices already createdBad dynamic max Value downstreamInconsistency between the services already created and the modified dynamic zone in the downstream.Update the dynamic zone with a value compatible with the dynamic service already created and the overbooking factor limit
3CC12426AAAA TQ BJA 01 Issue 01 - April 2001 - Draft 04 343/346344A.6.8 – ASAP error messagesA.6.9 – Miscellaneous error messagesBad dynamic Value ups-tream xInconsistency between the services already created and the modified dynamic zone in the upstream.Update the dynamic zone with a value compatible with the dynamic service already created and the overbooking factor limitBad dynamic max Value upstream x(x from 1 to 4)  Update over booking factor limit with a value compatible with the dynamic services created and the dynamic zone.Message Definition Corrective actionsError removing ASAP The ASAP cannot be removed because at least one NT is attached to the ASAP table.Before removing, the ASAP table has to be deleted for each NT attached to the table.Message Definition Corrective actionsError when destroying the boardBoard deletion control denied.  The corrective action is related tothe type of board:. AMD board: make sure that noNT is associated with the board.. TNT board: make sure that noport is used either by a leasedline or as a potential source ofsynchronization.. NT board: make sure that noport is used either by a leasedline or by an IP cross-connection.Error when modifying the TNT boardThe modification of the TNT board characteristics cannot be taken into account.All circuit emulation services must be suppressed before modifying the configuration of a TNT board.Error when updating the BSIn BS's local network screen one parameter is not correct.- Check that BS's IP address is areal IP address.- Check that Ethernet and ATMnetworks are different.Error when setting syn-chro parametersSynchronization configuration is not allowed. Check that the reserved chan-nels are configured (see § 4.11).Error when enabling/ disabling E1 traffic on a TNT portEnabling/disabling is not allowed. If the TNT port is used for system synchronization, the TNT port cannot be locked.Message Definition Corrective actions
344/346 Issue 01 - April 2001 - Draft 04 3CC12426AAAA TQ BJA 01344PAGE INTENTIONALLY LEFT BLANK
3CC12426AAAA TQ BJA 01 Issue 01 - April 2001 - Draft 04 345/346346Appendix 7 – List of abbreviations MNEMONIC ENGLISHAAL ATM Adaptation LayerAIS Alarm Indication SignalAL AlarmAMD ATM Modulator DemodulatorANT ATM Network TerminationASAP Alarm Severity Assignment ProfileATM Asynchronous Transfer ModeAT Attend alarm on LTAVC Attribute Value ChangeBER Bit Error RateBNC Bayonet-locking ConnectorBS Base StationCBR Constant Bite RateCCIR International radio consultativecomiteeCEPTConference of European Post and Telecommunications administra-tionsCPL CouplerCRC Cyclic Redundancy CheckDBS Digital Base StationEMC ElectroMagnetic CompatibilityEPROM Electronically ProgrammableRead-Only MemoryETSI European Telecommunications Standards InstituteETH EthernetFAS Frame Alignment SignalFEC  Forward Error CorrectionHDB3 High Density Binary 3 code(3rd order)IBS Intermediate frequency Base Sta-tionICS Identifier Change StatusI2C or IIC Inter Integrated CircuitID IDentifierIEC International ElectrotechnicalCommissionIM Information ModelIP Internet ProtocolISDN Integrated Services Digital NetworkITU International Telecommunication UnionLAIS Line Alarm Indication SignalLAN Local Area NetworkLED Light Emitting DiodeLMDS Local Multipoint Distribution ServiceLMFA Loss of MultiFrame AlignmentLOF Loss Of FrameLOP Loss Of PointerLOPC Loss Of Polling CellLORF Loss Of Radio FrameLOS Loss Of SignalLRDI Line Remote Defect IndicatorLT Local TerminalMAC Medium Access ControlMbps Mega Bit Per SecondMIB Management Information BaseMMI Man Machine InterfaceMSC Message Sequence ChartMUX MultiplexerNE Network ElementNFS Network File SystemNIT Network Installation ToolNRZ  Non return to zeroNT Network TerminalMNEMONIC ENGLISH
346/346 Issue 01 - April 2001 - Draft 04 3CC12426AAAA TQ BJA 01346END OF DOCUMENTOC Object CreationOD Object DeletionOOF Out Of FrameOS Operation SystemPAIS Path Alarm Indication SignalPC Personal ComputerPCR Peak Cell RatePDH Plesiochronous Digital HierarchyPLL Phase Locked LoopPSU Power Supply UnitPVC Permanent Virtual CircuitQAM Quadrature amplitude ModulationRAI Remote Alarm IndicatorX-Pol RBS Radio of Base StationRDI Remote Defect IndicationREI Remote Error IndicationRF Radio FrequencyRIT Radio Installation ToolRT Radio TerminalSC State ChangeSDH Synchonous Digital HierarchySMD Surface Mounted DeviceSNMP Simple Network ManagementProtocolSNTP Simple Network Time ProtocolSTP Shielded Twisted PairTAC Technical Assistance CenterTCP Transmission Control ProtocolTDM Time Division MultiplexTE Transaction EndTNT TDM Network TerminationTS Terminal StationUNI User Network InterfaceMNEMONIC ENGLISHVPI Virtual Path IdentifierVCI Virtual Channel IdentifierWAN Wide Area NetworkX-Pol RT Cross Polarized Radio TerminalX-Pol RBS Rx Cross Polarized Radio Base Sta-tion ReceptionX-Pol RBS Tx Cross Polarized Radio Base Sta-tion EmissionMNEMONIC ENGLISH