Alcatel Canada 31T28A04A22A Alcatel 7390 LMDS Broadband Wireless System - 31GHz User Manual 3cc12426aaaaTQbja01

Alcatel Canada Inc Alcatel 7390 LMDS Broadband Wireless System - 31GHz 3cc12426aaaaTQbja01

Base Station User Manual 10 0f 14

3CC12426AAAA TQ BJA 01 Issue 01 - April 2001 - Draft 04 301/3463027.5 – Sub-band distribution plan   (*) : figures given here represent the total bandwidth, i.e. from the lower edge of the lowest channel tothe higher edge of the highest channel.Cross-polarized radio Down-link Up-linkLMCS/AB 27 850 ¾ 28 350 27 350 ¾ 27 650LMCS/F 25 600 ¾ 25 850 25 350 ¾ 25 600LMCS/C 27 100 ¾ 27 350 26 850 ¾ 27 100LMDS/A 27 500 ¾ 28 350 31.075 ¾ 31 225LMDS/B 31 225 ¾ 31 300 31 000 ¾ 31 07538/700/1 39 700 ¾ 40 000 39 000 ¾ 39 300
302/346 Issue 01 - April 2001 - Draft 04 3CC12426AAAA TQ BJA 01302
3CC12426AAAA TQ BJA 01 Issue 01 - April 2001 - Draft 04 303/346308Appendix 1 – Installation sheetA.1.1 – 7390DBSGeneral information:Operator................. Date.......... Visa..........Equipment characteristicsNameAddress........................................................................................No .........       Street......................................................Bld.........          Stair...................        Floor.................Town .............................................................Country .........................................................OperatorSite identificationName of Base StationVersionDesignation Reference ICS Serial No.SubrackFanPSU 1PSU 2CPLIBS 1IBS 2IBS 3IBS 4IBS 5IBS 6IBS 7IBS 8
304/346 Issue 01 - April 2001 - Draft 04 3CC12426AAAA TQ BJA 01308Equipment characteristics and onboard softwareDesignation Part number ICS Serial No. Downloaded softwareANT 1ANT 2TNT 1TNT 2TNT 3TNT 4AMD 1AMD 2AMD 3AMD 4AMD 5AMD 6AMD 7AMD 8
3CC12426AAAA TQ BJA 01 Issue 01 - April 2001 - Draft 04 305/346308A.1.2 – 7390 X-Pol RBSGeneral information:Operator.................. Date............. Visa..........Equipment characteristicsInitial configuration (1+0):NameAddress...................................................................................No .........       Street................................................Bld.........          Stair...................        Floor...........Town .............................................................Country .........................................................OperatorSite identificationName of Base StationVersionDesignation 1 2 3 4MainsReferenceICSSerial No.Tx levelBandSub-bandType of cableLength of cableCable attenuateur (upstream)Cable attenuateur (downstream)TiltAzimuthHeight of X-Pol RBSType of Mounting
306/346 Issue 01 - April 2001 - Draft 04 3CC12426AAAA TQ BJA 01308Redundancy (1+1):Designation 5 6 7 8MainsReferenceICSSerial No.Tx levelBandSub-bandOnboard software versionType of cableLength of cableTiltAzimuthHeight of X-Pol RBSType of Mounting
3CC12426AAAA TQ BJA 01 Issue 01 - April 2001 - Draft 04 307/346308A.1.3 – Check point list for BS commissioningCHECKING THE SAFETY REGULATIONS:– Equipment ground wire OK NOK– Differential protection OK NOK– Fire protection OK NOKCHECKING THE RADIO INSTALLATION:– No contaminants or possible outflow on the antennas and radio OK NOK– No personnel allowed in the antenna fields OK NOK– Use of torque wrenchs for the radio assembly OK NOK– Mast rigidity and absence of vibration OK NOK– Antenna clearance in immediate vicinity OK NOK– Check that the ET390998 coaxial cable is installed OK NOK– Radio grounding OK NOKCHECKING THE WIRING BETWEEN X-Pol RBS AND DBS:– No crushed cables OK NOK– Observance of the minimum bend radius OK NOK– Quality of cable ground wire installation OK NOK– Sealing of ground relays on the cable OK NOKCHECKING THE DBS INSTALLATION:– Min Max temperature of the premises containing the DBS (-5º to +55ºC) OK NOK– Check air inlets and outlets of the DBS backplane  OK  NOK– Check the 48 Volt polarity  OK  NOK– Check the ground wire of the DBS backplane  OK  NOK– Check that all the client access cables are shielded  OK  NOK– On the DBS panel, J101, J104 and J113 must not be connected  OK  NOK– Check the optical fiber routing  OK  NOK– Check the connection sequence of the X-Pol RBS cables on the panel  OK  NOK
308/346 Issue 01 - April 2001 - Draft 04 3CC12426AAAA TQ BJA 01308PAGE INTENTIONALLY LEFT BLANK
3CC12426AAAA TQ BJA 01 Issue 01 - April 2001 - Draft 04 309/346324Appendix 2 – Installation of 7390LT softwareA.2.1 – Requirements1. Microsoft Windows NT operating system running (Service Pack 5 or above)2. A7390LT installation Kit3. User account with Administrator privileges to log-on withNote: Users without Administrator privileges will not be able to install SNTP service, required to runproperly the A7390LT.A.2.2 – Installation Procedure1. Be sure you have administrator rights2. Close all the aplications before start the 7390LT Installation3. Insert the CD " 7390LT Software Package"• The window " 7390LT Software Package" appears
310/346 Issue 01 - April 2001 - Draft 04 3CC12426AAAA TQ BJA 01324•Click on "Install Software"• The window "Install Software" appears•Click on "7390LT Application Software Release 2.2a"4. When the "Welcome" screen appears (see below), click on "Next" button to continue the installation
3CC12426AAAA TQ BJA 01 Issue 01 - April 2001 - Draft 04 311/346324procedure or press "cancel" to exit the installation program.5. The "Choose Destination Location" screen appears (see below). If you agree with the defaultdestination folder, click on the "Next" button. If you disagree, you can change it by clicking on"Browse" button and selecting the desired destination folder.Nota :– If you use always the default directory, un-install the previous LT version before.– If you want to install several LT versions on the same computer, use different folders at each time.6. The "Select Program Manager Group" screen appears (see below). If you agree with the default
312/346 Issue 01 - April 2001 - Draft 04 3CC12426AAAA TQ BJA 01324group name, click on "Next" button. If you disagree, you can change it by typing the desired name.Note: If you want to install several LTs on the same computer use different names for the Programgroup.7. The "Start Installation" screen appears (see below). Now, you are ready to install the A7390LT (CraftTerminal) in your computer. Click on the "Next" button to install it. You can cancel the LT installationby clicking on the "cancell" button or you can chnage some of the choosen options by clicking on the"Back" button.
3CC12426AAAA TQ BJA 01 Issue 01 - April 2001 - Draft 04 313/3463248. The following window appears indicating that the LT installation is running.9. If you dont't have administrator rights, the following window appears. The LT installation has notbeen completely succesful, so you have to get administrator rights and start again.
314/346 Issue 01 - April 2001 - Draft 04 3CC12426AAAA TQ BJA 0132410. The installation has been completed. The following window appears. Press OK to restart yourcomputer.11. After copying files, the Simple Network Time Protocol (SNTP) service is installed and started. Afterthis, the installation process is complete.12. Now, you are ready to run the 7390LT application.
3CC12426AAAA TQ BJA 01 Issue 01 - April 2001 - Draft 04 315/346324A.2.3 – License the .OCX files1. Run the Ptlic32.exe file located in :C:\Program_files\7390LT-Craft Terminal\Ptlic32.exeThe "Power TCP" windows appears.2. Click on the "Licensing" buttonThe following window appears:3. Enter the following values4. Click on AddThe license is printed in the box "Installed License"5. Click on the license6. Click on the "Stamp license" button7. Select the following OCX file to stamp the license:C:\WinNT\System32\ptsnmp32.ocxA window appears on the screen mentioning that the licensing has been done succesfully.8. Move back to the main window (see window above), click on the license detailed in the box "InstalledLicense", and then click on the Delete button.Field ValuePart PT-119S/N 119-4-697-23346Company Alcatel CIT

Navigation menu