Airspan Networks AS1300 Base station of LTE fixed cellular system User Manual AirStrand 1300 Installation Guide

Airspan Networks Inc Base station of LTE fixed cellular system AirStrand 1300 Installation Guide

Users Manual

                      AirStrand 1300 Installation Guide                Part Number: DUG01370-SP System Release: 15.5 Revision: A Published: January 2018
  © Copyright by Airspan Networks Inc., 2017 - 2018. All rights reserved worldwide. Legal Notices The information contained within this document is proprietary and is subject to all relevant copyright, patent and other laws protecting intellectual property, as well  as  any specific agreements protecting Airspan  Networks Inc.  rights  in  the  aforesaid information. Neither this document nor the information contained herein may be published, reproduced or disclosed to third parties, in whole or in part, without the express, prior, written permission of Airspan Networks Inc. In addition, any use of this document or the information contained herein for the purposes other than those for which it is disclosed is strictly forbidden. Airspan Networks Inc. reserves the right, without prior notice or liability, to make changes in equipment design or specifications. Information supplied by Airspan Networks Inc. is believed to be accurate and reliable. However, no responsibility is assumed by Airspan Networks Inc. for the use thereof nor for the rights of third parties which may be effected in any way by the use of thereof. Any  representation(s)  in  this  document  concerning  performance  of  Airspan  Networks  Inc.  product(s)  are  for  informational purposes only and are not warranties of future performance, either expressed or implied. Airspan Networks Inc. standard limited warranty, stated in its sales contract or order confirmation form, is the only warranty offered by Airspan Networks Inc. in relation thereto. This document may contain flaws, omissions or typesetting errors; no warranty is granted nor liability assumed in relation thereto unless specifically undertaken in Airspan Networks Inc. sales contract or order confirmation. Information contained herein is periodically updated and changes will be incorporated into subsequent editions. If you have encountered an error, please notify Airspan Networks Inc. All specifications are subject to change without prior notice. Product performance figures quoted within this document are indicative and for information purposes only.  Acknowledgements   © Intel Corporation    http://www.intel.com/   © Microsoft Corporation     http://www.microsoft.com
DUG01370-SP Airspan Commercial and Internal Use   i  Table of Contents Document Information ............................................................................. 1 Abstract .................................................................................................................. 1 Revision History ..................................................................................................... 1 Warnings and Cautions ........................................................................... 2 Human Exposure to Radio Frequencies ................................................................ 2 Avertissement et Precautions d’Utilisation .............................................. 2 Radio Interference ................................................................................................. 2 Modifications .......................................................................................................... 2 General .................................................................................................................. 2 Général .................................................................................................................. 2  Important Safety Instructions ............................................................................ 3 Safety ..................................................................................................................... 3 Securite .................................................................................................................. 4 Warning of Hazardous Voltages ............................................................................ 4 Attention aux Voltages Hasardeux ......................................................................... 4 Adherence to European Directive 1999/5/EC ........................................................ 5 Warning Symbols ................................................................................................... 5 Service Information ................................................................................................ 5 UL Information ....................................................................................................... 6 Power Rating ......................................................................................................... 6 Lightning Protection ............................................................................................... 6 DECLARATION OF CONFORMITY....................................................................... 7 GPS Compliance ................................................................................................... 8 Maximum Output TX Total Power ........................................................... 9 Power Consumption ............................................................................................... 9 Antenna System ................................................................................................... 10 About This Document ........................................................................... 11 Purpose ................................................................................................................ 11 Intended Audience ............................................................................................... 11
AirStrand 1300 Installation Guide  DUG01370-SP Airspan Commercial and Internal Use  ii Document Conventions ........................................................................................ 11 Related Reading .................................................................................................. 12 Customer Care Help Desk .................................................................... 13 Airspan Encourages Comments .......................................................................... 13 1 Introduction ....................................................................................... 14 1.1 AirStrand 1300 .............................................................................................. 14 1.1.1 Deployment .................................................................................................. 14 2 Getting Started .................................................................................. 16 2.1 Workflow of Installation ................................................................................. 16 2.2 AirStrand 1300 Installation Checklist ............................................................. 16 3 Verifying Prerequisites ...................................................................... 17 3.1 Verifying Site Requirements .......................................................................... 17 3.2 Verify Installation Requirements .................................................................... 17 3.2.1 Verify the Tools ............................................................................................ 17 3.2.2 Verify the Parts and Kits ............................................................................... 18 3.2.3 Power ........................................................................................................... 19 3.2.4 Physical Dimensions .................................................................................... 19 4 Installation of AirStrand 1300 ............................................................ 20 4.1 Strand Mounting of AirStrand 1300 ............................................................... 20 4.1.1 Bracket Assembly on the AirStrand 1300 ..................................................... 21 4.1.2 GPS Bracket Adjustment .............................................................................. 23 5 Connecting and Managing Cables .................................................... 24 5.1 Connecting the Ground Cable ....................................................................... 24 5.2 1300 Interface Connection ............................................................................ 24 5.2.1 Connecting the CATV Cable ........................................................................ 24 5.2.2 Accessing the Attenuator(s) and Test Port ................................................... 25 5.2.3 Replacing the Maintenance Cover ................................................................ 26 A Job Sheet .......................................................................................... 28 B Installation Checklist.......................................................................... 29 C Abbreviations .................................................................................... 30
AirStrand 1300 Installation Guide  DUG01370-SP Airspan Commercial and Internal Use  iii  Figures Figure 1: AirStrand 1300 ....................................................................................................................... 10 Figure 2: AirStrand 1300 ....................................................................................................................... 15 Figure 3: Workflow ................................................................................................................................ 16 Figure 4: Hanger and Clamp Assembly ................................................................................................ 21 Figure 5: Mounting Hanger Assembled ................................................................................................ 21 Figure 6: Hanger Bracket Assembly on Unit ......................................................................................... 22 Figure 7: Unit on Cable Strand ............................................................................................................. 22 Figure 8: GPS Bracket Adjustment ....................................................................................................... 23 Figure 9: Ground Cable Connection ..................................................................................................... 24 Figure 10: Connect CATV Cable .......................................................................................................... 25 Figure 11: Removable Maintenance Cover .......................................................................................... 25 Figure 12: Maintenance Cover Open .................................................................................................... 26 Figure 13: Screw Tightening Pattern .................................................................................................... 27 Tables   Table 1: AirStrand 1300 B41 FCC Maximum Output TX Total Power .................................................... 9 Table 2: AirStrand 1300 B41 ETSI Maximum Output TX Total Power ................................................... 9 Table 3: Power Consumption .................................................................................................................. 9 Table 4: Typographic Conventions ....................................................................................................... 11 Table 5. Minimum Hardware Requirements ......................................................................................... 17 Table 6: AirStrand 1300 Components ................................................................................................... 18 Table 7: Power ...................................................................................................................................... 19 Table 8. AirStrand 1300 Physical Dimensions ...................................................................................... 19
    AirStrand 1300T Installation Guide  DUG01370-SP Airspan Commercial and Internal Use   1  Document Information   Abstract This document details procedures for installing the Airspan’s AirStrand 1300 Pico-class LTE eNodeB variant.  Revision History Revision Details Date Summary of Changes 0.1 – 0.2 November 2017   Initial document & comments A & A1 November 2017   Publish   Comments A2 + A3 December 2017   Tx Power update   Updates from Comments A4 January 2018   Modifications and Updates
AirStrand 1300 Installation Guide  DUG01370-SP Airspan Commercial and Internal Use  2 Warnings and Cautions Human Exposure to Radio Frequencies The AirStrand 1300 when operational should be operated from a minimum safe distance of 2m. Avertissement et Precautions d’Utilisation Exposition des personnes aux fréquences radioélectriques Les antennes d’AirStrand 1300 quand opérationnel doivent être installée et utilisée de façon à garantir la distance minimale de sécurité de 2m. Radio Interference This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction  manual,  may  cause  harmful  interference  to  radio  communications.  Operation  of  this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Modifications Any changes and modifications to this device that are not expressly approved by Airspan Networks may void the user's authority to operate the equipment. General   Only qualified personnel should be allowed to install, replace, and service the equipment.   The device cannot be sold retail, to the general public or by mail order. It must be sold to operators.   Installation must be controlled.   Installation must be performed by licensed professionals.   Installation requires special training. The AirStrand 1300 radio and antenna should be installed ONLY by experienced installation professionals who are familiar with local building and safety codes and, wherever applicable, are licensed by the appropriate government regulatory authorities. Failure to do so may void Airspan's product warranty and may expose the end user or the service provider to legal and financial liabilities. Airspan and its resellers or distributors are not liable for injury, damage or violation of regulations associated with the installation of outdoor units or antennas.   The device is to be installed in a Restricted Access Location.   Power provided by PoE output cannot be considered limited power source (LPS) per IEC/UL 60950-1 clause 2.5.   Connection to the PoE port is permitted only by certified electrician according to NEC requirements.   Connect PoE terminal only to equipment which does NOT require “LPS only” feeding. Général   Seul le personnel qualifié peut être autorisé pour installer ou remplacer l’équipement ainsi qu’effectuer les opérations de maintenance pour cet équipement.
AirStrand 1300 Installation Guide  DUG01370-SP Airspan Commercial and Internal Use  3  L’équipement ne peut pas être vendu en grande distribution ou par commande via email à destination du public. Il doit être vendu aux opérateurs de télécommunications.   Son installation doit être contrôlée   Son Installation doit être effectuée par des professionnels autorises.  Son installation requiert une formation spécifique du personnel. L’AirStrand 1300, radio et antenne doit être installe UNIQUEMENT par des installateurs professionnels expérimentés et ayant une connaissance des constructions locales et règles de sécurité, ainsi que, dès que nécessaire, disposant d’un agreement des autorités gouvernementales de régulation. Toute enfreinte a ces obligations peut  annuler la garantie délivrée par Airspan pour ces produits et peut exposer l’utilisateur final ou le fournisseur de services a des dommages légaux et financiers.   Airspan et ses revendeurs ou ses distributeurs ne sont pas responsables des blessures, dommages ou violations de la régulation en vigueur lies a l’installation du système extérieur ou des antennes.  L’Equipment doit être installe dans une zone a accès réduit et contrôle.  L’alimentation fournie par la sortie PoE ne peut pas être considérée comme une Source d’Alimentation Limitée ( ou LPS – limited power source ) selon le standard IEC/UL 60950-1 clause 2.5    La connexion au port PoE est autorisée par un électricien certifie selon les standards NEC.   Connecter le port PoE uniquement aux équipements NE demandant PAS un source de type ‘’ LPS only  Important Safety Instructions   Read and Save these instructions   This Installation Guide contains instructions and warnings that should be followed during installation, and operation.    Failure to follow these instructions could cause bodily injury and/or product failure. Safety  1.  Read this guide and follow all operating and safety instructions. 2.  Supply cord is not shipped with the unit and is to be provided by user. Installation is to be performed by a qualified electrician according to local codes. Installation to be done in accordance with the National Electrical Code (NEC), ANSI/NFPA 70, the Canadian Electrical Code (CEC), Part I, CAN/CSA C22.1, and when applicable, the National Electrical Safety Code, IEEE C2. 3.  Static sensitive components inside - do not remove the lid or base: No user serviceable parts inside. 4.  The ground connection should be made before connecting to supply connections. 5.  Position the power cord to avoid possible damage; do not overload circuits. 6.  Do not place this product on or near a direct heat source, and avoid placing objects on the terminal. 7.  To avoid electrical shock do not install this device during adverse conditions such as rain or inclement weather. 8.  The units should not be located too near power lines or other electrical power circuits, where it can come into contact with such power lines or circuits. 9.  The radio transceiver must be properly grounded to protect against power surges and accumulated static electricity. It is the user’s responsibility to install this device in accordance with the local electrical codes. 10.  Installation of the AirStrand 1300 must be contracted to a professional installer.
AirStrand 1300 Installation Guide  DUG01370-SP Airspan Commercial and Internal Use  4 11.  The circuit breaker should be easily accessible in case you have to disconnect the device. 12. When installed in the final configuration, the product must comply with the applicable Safety Standards and regulatory requirements of the country in which it is installed. If necessary, consult with the appropriate regulatory agencies and inspection authorities to ensure compliance. Securite 1. Lire attentivement ce guide et suivre les instructions d’utilisation et de sécurité. 2. Le cordon d’alimentation n’est pas livré avec l'appareil et doit être fourni par l'utilisateur. L’installation doit être effectuée par un électricien qualifié conformément aux règles et standards locaux. L’installation doit être effectuée en conformité avec le Code national de l'électricité ( NEC ), ANSI / NFPA 70, le Code canadien de l'électricité (CCE ), Partie I, CAN / CSA C22.1, et le cas échéant, le Code national de sécurité électrique, IEEE C2. 3. Des composants sensibles a électricité statique sont utilisés à l’intérieur. Ne pas retirer le coffre ou la base. Aucune pièce a l’intérieur est d’utilité pour l’utilisateur. 4.  La connexion "terre" doit être effectuée en priorité et avant d'effectuer les connexions à la source d'alimentation (phase et neutre). 5. Positionner le cordon d’alimentation de façon à éviter des dommages potentiels. Ne pas surcharger les circuits. 6.  Ne pas placer ce produit sur ou à proximité d’une source directe de chaleur et éviter de placer des objets sur le terminal. 7. Afin d’éviter des problèmes électriques, ne pas installer cet équipement au cours d’évènements climatiques difficiles comme averses ou météo non clémente. 8. L’unité ne doit pas être située trop près de lignes électriques ou autres circuits de puissance, avec lesquels il pourrait entrer en contact. 9. L’émetteur radio doit être correctement relie a la terre afin de le protéger contre les surtensions ou accumulation d’électricité statique. L’utilisateur est tenu responsable de l’installation du produit conformément aux règles électrique en vigueur localement. 10. L’installation de AirStrand 1300 doit être contractualisée avec un installateur professionnel. 11. L’interrupteur de circuit électrique doit être facilement accessible afin de pouvoir déconnecter l’équipement. 12.  Lors de l’installation de la configuration finale, le produit doit être conforme aux Standards de Sécurité en vigueur ainsi qu’aux exigences réglementaires du pays dans lequel il est installé. Si nécessaire, consulter les agences règlementaires appropriées, ainsi que les autorités chargées de l’inspection afin de garantir la conformité. Warning of Hazardous Voltages On AC installations, hazardous voltages exist.  Use caution when verifying or working with AC power.  Remove metal jewellery that could come into contact with AC power. On DC sections, short-circuiting the low voltage, low impedance circuits can cause severe arcing that may result in burns or eye damage.  Remove rings, watches etc. to avoid shorting DC circuits. Note: Airspan products do not contain hazardous substances (as defined in UK Control of Substances Hazardous to Health Regulations 1989 and the Dangerous Substances Regulations 1990).  At the end of any Airspan products life cycle, the customer should consult with Airspan to ensure that the product is disposed of in conformance with the relevant regulatory requirements. Attention aux Voltages Hasardeux
AirStrand 1300 Installation Guide  DUG01370-SP Airspan Commercial and Internal Use  5 Sur  les  installations  de  réseau  électrique  de  type  courant  alternatif  (CA),  des  voltages  hasardeux peuvent  survenir.  Garder  une  Attention  particulière  lors  d’une  vérification  ou  de  travaux  sur  réseau électrique CA. Retirer tous bijoux en métal qui pourraient entrer en contact avec l’alimentation ou  le réseau CA. Sur les portions de réseau électrique de type courant continu (CC), un circuit basse impédance peut causer de sérieux arcs électriques qui pourraient bruler ou endommager  les  yeux. Retirer bagues, anneaux, montres etc… afin d’éviter les court-circuit sur le réseau CC. Adherence to European Directive 1999/5/EC European Council Recommendation 1999/5/EC details basic restrictions and reference levels on human exposure to electromagnetic fields as advised by the ICNIRP. Adherence to these recommended restrictions and reference levels should provide a high level of protection as regards the established health effects that may result from exposure to electromagnetic fields.  Airspan  equipment  is  compliant  with  CE  and  R&TTE  regulations  and  can  be  operated  in  all  EU (European Union) locations listed below: Country Code BE EL LT PT BG ES LU RO CZ FR HU SI DK HR MT SK DE IT NL FI EE CY AT SE IE LV PL UK Warning Symbols The following symbols may be encountered during installation or troubleshooting. These warning symbols mean danger. Bodily injury may result if you are not aware of the safety hazards involved in working with electrical equipment and radio transmitters. Familiarize yourself with standard safety practices before continuing.     Caution, hot surface Caution Electro-Magnetic Radiation High Voltage Service Information Refer all repairs to qualified service personnel. Do not modify any part of this device, as this will void the warranty. Disconnect the power to this product and return it for service if the following conditions apply: a.  The terminal does not function after following the operating instructions outlined in this manual.
AirStrand 1300 Installation Guide  DUG01370-SP Airspan Commercial and Internal Use  6 b.  The product has been dropped or the housing is damaged. Locate the serial number of the terminal and record this on your registration card for future reference. Also record the MAC address, located on the product sticker. UL Information - The equipment must be properly grounded according with NEC and other local safety code requirements. - Reminder to all the BWA system installers: Attention to Section 820-40 of the NEC which provides guidelines for proper grounding and, in particular, specifies that the cable ground shall be connected to the grounding system of the building, as close to the point of cable entry as is practical. Power Rating 40-90 VAC 47/63Hz 1.4A Lightning Protection WARNING: The following notes are general recommendations for the system. The wireless equipment should be installed by a qualified professional installer and must follow local and national codes for electrical  grounding  and  safety.  Failure  to  meet  safety  requirements  and/or  use  of  non-standard practices and procedures could result in personal injury and damage to equipment. A direct lightning strike may cause serious damage even if these guidelines are followed. All outdoor wireless equipment is susceptible to lightning damage from a direct hit or induced current from a near strike. Lightning protection and grounding practices in local and national electrical codes serve to minimize equipment damage, service outages, and serious injury. The antennas are to be DC grounded, so surge protection is not required. Reasons for lightning damage are summarized as: - Poorly grounded tower/antenna sites that can conduct high lightning strike energy into equipment. -  Lack  of  properly  installed  lightning  protection  equipment  that  can  cause  equipment  failures  from lightning induced currents. A lighting protection system provides a means by which the energy may enter earth without passing through and damaging parts of a structure. A lightning protection system does not prevent lightning from striking; it provides a means for controlling it and preventing damage by providing a low resistance path for the discharge of energy to travel safely to ground. Improperly grounded connections are also a source of noise that can cause sensitive equipment to malfunction. A good tower grounding system disperses most of the surge energy from a tower strike away from the building and equipment. To limit the equipment damage due to a lightning strike, the following practices are recommended for the wireless system: -  Provide  direct  grounding  from  the  antenna  mounting  bracket,  the  radio  and  antenna  and  the lightning/surge protectors to the same ground point at the base of the tower or a ground bus on the building. Use the grounding screws on the antenna bracket and the radio and antenna for terminating the ground wires. - The circuit ground must be connected to the same grounding system as the eNodeB.
AirStrand 1300 Installation Guide  DUG01370-SP Airspan Commercial and Internal Use  7 DECLARATION OF CONFORMITY European Community, Switzerland, Norway, Iceland, and Liechtenstein  Declaration of Conformity with Regard to the R&TTE Directive 1999/5/EC English:  This  equipment  is  in  compliance  with  the  essential  requirements  and  other  relevant  provisions  of Directive 1999/5/EC.  Deutsch:  Dieses  Gerät  entspricht  den  grundlegenden  Anforderungen  und  den  weiteren  entsprecheneden Vorgaben der Richtlinie 1999/5/EU.   Dansk:  Dette udstyr er i overensstemmelse med de væsentlige krav og andre relevante bestemmelser i Directiv 1999/5/EF.   Español:  Este equipo cumple con los requisitos esenciales asi como con otras disposiciones de la Directive 1999/5/EC.   Greek:  ΜΕ  ΤΗΝ  ΠΑΡΟΥΣΑ  Airspan  ΔΗΛΩΝΕΙ  ΟΤΙ  Ο  ΕΞΟΠΛΙΣΜΟΣ  ΣΥΜΜΟΡΦΩΝΕΤΑΙ  ΠΡΟΣ  ΤΙΣ ΟΥΣΙΩΔΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΤΗΣ ΟΔΗΓΙΑΣ 1999/5/ΕΚ.   Français:  Cet appareil  est  conforme  aux  exigencies  essentialles  et  aux  autres  dispositions  pertinantes  de  la Directive 1999/5/EC.   Íslenska:  Þessi búnaður samrýmist lögboðnum kröfum og öðrum ákvæðum tilskipunar 1999/5/ESB.   Italiano:  Questo apparato é conforme ai requisiti essenziali ed agli altri principi sanciti dalla Direttiva 1999/5/EC.   Nederlands:  Deze apparatuur voldoet aan de belangrijkste eisen en andere voorzieningen van richtlijn 1999/5/EC.   Norsk:  Dette utstyret er i samsvar med de grunnleggende krav og andre relevante bestemmelser i EU-directiv 1999/5/EC.   Português:  Este equipamento satisfaz os requisitos essenciais e outras provisões da Directiva 1999/5/EC.   Suomalainen:  Tämä laite täyttää direktiivin 1999/5/EY oleelliset vaatimukset ja on siinä asetettujen muidenkin ehtojen mukainen.   Svenska:  Denna utrustning är i överensstämmelse med de väsentliga kraven och andra relevanta bestämmelser i Direktiv 1999/5/EC. Român: Acest echipament este în conformitate cu cerinţele esenţiale şi alte prevederi relevante ale Directivei 1999/5/CE.  The Declaration of Conformity related to this product can be obtained from PLM@Airspan.com.
AirStrand 1300 Installation Guide  DUG01370-SP Airspan Commercial and Internal Use  8 GPS Compliance The GPS is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC." The GPS complies with the following EMC Common Regulatory Testing standards:   EN55022: Radiated and Conducted Emissions   CISPR 22: Class B   EN 50081-1: Generic Emissions Class B   EN 50082-1: Generic Immunity Class B   EN 61000-4-2: Electrostatic Discharge Immunity   EN 61000-4-3: Radiated RF EM Field Immunity Test   EN 61000-4-4: Electrical Fast Transient/Burst Test   EN 61000-4-6: Conducted Immunity   EN 61000-4-8: Magnetic Field Immunity Note: A GPS is recommended for synchronizing between LTE sectors.  Note: An optional GPS Lightning/Surge protector is available from Airspan when installing the GPS antenna in a remote location for lightning prone deployments.
AirStrand 1300 Installation Guide  DUG01370-SP Airspan Commercial and Internal Use  9 Maximum Output TX Total Power  Table 1: AirStrand 1300 B41 FCC Maximum Output TX Total Power Frequency Band FCC TX                  EIRP Antenna Gain 2496 – 2690 MHz 30.4 dBm 40.9 dBm 10.5dBi   Table 2: AirStrand 1300 B41 ETSI Maximum Output TX Total Power Frequency Band ETSI TX                  EIRP Antenna Gain 2496 – 2690 MHz 30 dBm 40.5 dBm 10.5dBi  Caution: Do not set maximum output TX power to higher than local regulations. Power Consumption AirStrand 1300 has a nominal power consumption of 40W. AirStrand 1300 power consumption is described in the following table:  Table 3: Power Consumption Duplex Tx Power at RF Port (dBm) Nominal Power Consumption (W) TDD Sec1: 26 Sec2: 26 45
AirStrand 1300 Installation Guide  DUG01370-SP Airspan Commercial and Internal Use  10 Antenna System The eNB solution is based on a dual sector model that can be operated as a dual sector / dual carrier mode of operation. There are 2x directional 2x2 antennas which are positioned perpendicular to the strand (back to back). Figure 1: AirStrand 1300
AirStrand 1300 Installation Guide  DUG01370-SP Airspan Commercial and Internal Use  11 About This Document Purpose This guide provides the workflow and step-by-step procedures for Installing the AirStrand 1300.  These procedures include:   Verify prerequisites   Assemble Strand Brackets on Unit   Install the AirStrand 1300   Connect and manage cables Intended Audience This guide is intended for persons who are responsible for installing the AirStrand 1300 equipment. These persons should have a working knowledge of the equipment. Document Conventions This document uses the following typographic conventions.  Table 4: Typographic Conventions Convention Element Blue underlined text Cross-reference links. Bold text Keyboard buttons and GUI elements. Command Command names or phrases. Computer output Text displayed by the computer. Hyperlinks Website and e-mail addresses. Danger Signifies a hazardous situation—if not avoided—will cause death or serious injury. Describes how to avoid it. Warning Signifies a hazardous situation—if not avoided—can cause death or serious personal injury. Describes how to avoid it.  Caution Signifies a hazardous situation—if not avoided—can void the product warranty, and cause property damage. Describes how to avoid it. Important Provides necessary information to explain a task. Note Provides additional information. Tip Provides helpful hints.
AirStrand 1300 Installation Guide  DUG01370-SP Airspan Commercial and Internal Use  12 Related Reading The following documents contain related information:   AirStrand 1300 Hardware Product Specification Pending  Airspan LTE Commissioning Manual Pending
AirStrand 1300 Installation Guide  DUG01370-SP Airspan Commercial and Internal Use  13 Customer Care Help Desk Airspan’s Customer Care Help Desk offers prompt and efficient customer support services. Note: To avail Airspan’s Customer Care Help Desk support, you must be a registered user and must have a valid support contract. To register, click here and fill the Registration form. To create and update issue logs, send e-mails to Customer Care Help Desk. Once you submit your issue, the system generates a new issue and sends an issue number for your reference. The system uses this issue number to categorize and store e-mails under the appropriate issue. To help Customer Care Help Desk identify your issue, include the issue number and your Customer Care Helpdesk account details in all further communications. Main Operations Airspan Communications Ltd.  Capital Point  33 Bath Road  Slough, Berkshire  SL1 3UF, United Kingdom  Tel: +44-1895-467-100  Worldwide Headquarters Airspan Networks Inc. 777, Yamato Road, Suite 105 Boca Raton, FL 3341-4408, USA Tel: +1 561 893 8670 Airspan Encourages Comments Airspan welcomes any feedback and suggestions that help to improve the quality of the documentation. Send your feedback to documentfeedback@airspan.com.
AirStrand 1300 Installation Guide  DUG01370-SP Airspan Commercial and Internal Use  14 1  Introduction This section provides a descriptive overview of the Airspan’s AirStrand 1300 Pico-class eNodeB variant and its place in the Airspan product suite.  1.1 AirStrand 1300 AirStrand 1300 is part of Airspan’s carrier-class LTE advanced outdoor small cell eNodeB family. AirStrand 1300 is a Pico-class LTE eNodeB product, providing high-speed data, mobility, Voice over LTE, and broadcast/multicast services. AirStrand 1300 is a super compact, easy to install Pico-class Outdoor Small Cell Strand mounted eNodeB with an integrated DOCSIS (Alpha DSM33) backhaul solution. Allowing an operator to deploy LTE broadband services on a cable strand without the need for backhaul connectivity or infrastructure – It uses the already existing Macro layer for backhauling. AirStrand 1300 is a dual sector product which is operated as a single 2x2 MIMO cell of 20MHz channel using the advanced Lite-CoMP technology. AirStrand 1300 fully supports the standard LTE (Uu/S1/X2) interfaces. All Airspan eNodeB products, including AirStrand 1300, are interoperable with a rich portfolio of 3rd party end user devices, including many handsets, indoor UEs, outdoor UEs and USB dongles from several ODMs, using various chipsets. For an updated of interoperability list, please contact your nearest Airspan Sales Representative. Note: For management please refer to the AirStrand 1300 LTE Commissioning Manual as well as the Netspan User Manual. 1.1.1 Deployment AirStrand 1300 perfectly fits the requirements of the hard zoning outdoor locations such as hotels, city centers, parks and universities all due to its super compact one box form factor.   AirStrand 1300 creates a single install process for LTE Access and Backhaul, and enables “Just add Power” plug and play deployment method and along with the easy zoning of the product saving deployment related costs and time.   Note: The following is for illustration only; actual layout may differ as infrastructure is installation-specific.
AirStrand 1300 Installation Guide  DUG01370-SP Airspan Commercial and Internal Use  15  Figure 2: AirStrand 1300
AirStrand 1300 Installation Guide  DUG01370-SP Airspan Commercial and Internal Use  16 2  Getting Started 2.1 Workflow of Installation The Workflow to install the AirStrand 1300 is shown in the following diagram:   Figure 3: Workflow   2.2 AirStrand 1300 Installation Checklist Plan the installation of the AirStrand 1300 by using the Installation Checklist, which you can find as a removable job aid in Appendix A for this guide.
AirStrand 1300 Installation Guide  DUG01370-SP Airspan Commercial and Internal Use  17 3  Verifying Prerequisites Prior to installing the AirStrand 1300, verify the required safety, power, tools, parts and components. This chapter includes the hardware, software, and client requirements for installation. Important: Set up requirements for the installation is detailed in the Job Sheet, see Appendix A.  3.1 Verifying Site Requirements To set up the AirStrand 1300, an IP connection to a Netspan server is required. 3.2 Verify Installation Requirements 3.2.1 Verify the Tools  Table 5. Minimum Hardware Requirements Tool Use 9/16 inch wrench Tightening hanger 3/8-16 bracket nuts 1/2 inch wrench  Tightening hanger 5/16-18 bracket screws and nuts #10 (5/32) Allen wrench For adjusting the GPS slide screws Philips screw driver Good to have Torque screwdriver Tightening screws Adjustable Wrench For CATV 5/8” connector (if needed) Small flat blade screw driver (insulated shaft recommended) Good to have
AirStrand 1300 Installation Guide  DUG01370-SP Airspan Commercial and Internal Use  18 3.2.2 Verify the Parts and Kits The following figures display various AirStrand 1300 components and accessory kits. Note: Verify order and requirements to ensure the correct unit type is being installed.   Table 6: AirStrand 1300 Components Installation Kit / Part Product Code Airspan No. Consisting of Images AirStrand 1300 AT13-U41-B03S 998-73-419 SP AirStrand 1300 2.496 - 2.690 / 2.496 - 2.690 MHz (B41), DOCSIS Backhaul, DOCSIS Power  AirStrand Strand Mounting Kit AS12-SMK-1 Included in the main unit packaging 903-03-040 Strand bracket x 2 with Hanger clamps x 2 Hardware (bolts, threaded stud and nuts)
AirStrand 1300 Installation Guide  DUG01370-SP Airspan Commercial and Internal Use  19 3.2.3 Power AirStrand 1300 supports direct connection to AC Quasi-sine power source. To be fed from the HFC network. Operational Voltage Range: 44V~90V  Table 7: Power Power Source Nominal Power Consumption (W) Nominal Power Consumption (W) AC Quasi Sine 44V~90V 45 70   3.2.4 Physical Dimensions AirStrand 1300 is in an all outdoor enclosure.  Table 8. AirStrand 1300 Physical Dimensions Variant Dimensions (L x W x H) Comment Total size 16.5 x 5.5 x 8.5 in. / 420 x 140 x 203 mm The physical dimensions exclude connectors Volume 11.5L  Weight Complete Unit (including hangers) 24 Lbs. / 11 Kg.
AirStrand 1300 Installation Guide  DUG01370-SP Airspan Commercial and Internal Use  20 4  Installation of AirStrand 1300 AirStrand 1300 is installed on the strand (the steel cable) that runs from pole to pole supporting other cables, such as telephone and cable company cables that run from pole to pole. When mounting the AirStrand 1300 on a cable strand, you must use the Strand mount accessory kit. The kit contains several parts that you should assemble before mounting on a cable strand. The Strand Accessory  kit  contains  the  strand  bracket(s)  and  the  hanger  bracket(s)  (clamps)  with  the  required hardware (included) required for installation.  To install AirStrand 1300 to a cable strand, you need to perform these operations:   Assemble strand hanger brackets.   Attach the strand hanger brackets to the AirStrand 1300 unit.   Attach the hanger bracket clamps to the cable strand.   Connect interface (5/8” Interface connector type) to the cable infrastructure. 4.1 Strand Mounting of AirStrand 1300 Caution: Proper local rigging and hoisting practices should be followed when installing the AirStrand 1300.  Caution: The AirStrand 1300 is intended to be strand mounted in the telecommunications space between poles, not in the electrical space.
AirStrand 1300 Installation Guide  DUG01370-SP Airspan Commercial and Internal Use  21 4.1.1  Bracket Assembly on the AirStrand 1300 1.  Assemble the hanger clamp bracket (first verify the cable diameter, and select either the 6 mm or 8 mm hole configuration).  Figure 4: Hanger and Clamp Assembly   Note: Different sized strand(s) may be accommodated when securing hanger bracket by rotating the notched clamp to the suitable hole size, as displayed below.  Figure 5: Mounting Hanger Assembled
AirStrand 1300 Installation Guide  DUG01370-SP Airspan Commercial and Internal Use  22 2.  Assemble both strand brackets to the top of the unit. Inserting the 5/16”-18 bolts (provided) into the threaded holes. Note: Assemble the brackets in the direction as shown in Figure 6 below.  Figure 6: Hanger Bracket Assembly on Unit   3.   After assembly tighten down the bolts. 4.  Orient the AirStrand 1300 to enable optimal positioning prior to placing on strand cable. 5.  Lift assembled unit into place on the cable strand.  Figure 7: Unit on Cable Strand
AirStrand 1300 Installation Guide  DUG01370-SP Airspan Commercial and Internal Use  23  6.  Secure the hanger bracket on the strand.  4.1.2 GPS Bracket Adjustment After the AirStrand 1300 is securely fastened on the strand cable, the GPS and its bracket should be extended for maximum efficiency. 1.  Loosen the two (2) Hex Head Allen screws on the GPS slide, which is attached on the top of the slide bracket.  Figure 8: GPS Bracket Adjustment   2.  Extend the slide bracket. 3. Re-tighten the two (2) Hex Head Allen screws.
AirStrand 1300 Installation Guide  DUG01370-SP Airspan Commercial and Internal Use  24 5  Connecting and Managing Cables 5.1  Connecting the Ground Cable Once the AirStrand 1300 is securely attached on the strand it is advisable to connect an approved ground cable. Connect the ground cable after attaching a grounding lug to the ¼-20 threaded hole on the top of the AirStrand 1300 body, as shown below:  Figure 9: Ground Cable Connection   Note: Cutting the Ground cable to the required length and crimping the grounding lug is performed by the Installer.  Note: The threaded ¼-20 ground hole is bare metal and needs no preparation.  Note: The minimum cable gauge to be used for the ground wire is 9 AWG. 5.2  1300 Interface Connection Danger: Hazardous voltage!  Before working, ensure that the power is off prior to performing any connections.  5.2.1 Connecting the CATV Cable Once the AirStrand 1300 is securely attached on the strand the installer should connect the CATV cable terminated with an RF connector to the F-type connector (factory installed) connected to the unit’s connecting outlet. 1.  Connect the CATV cable terminated with an RF connector to the F-type connector connected (factory installed) to the unit’s connecting outlet. Note: Supplied with F-type connector adapter but other connectors (i.e. stinger) are available if required.
AirStrand 1300 Installation Guide  DUG01370-SP Airspan Commercial and Internal Use  25  Figure 10: Connect CATV Cable   Note: When securing the cable make sure there is no tension on the connector so that it is easy to disconnect and re-connect for future maintenance actions.  5.2.2 Accessing the Attenuator(s) and Test Port Note: Opening of the maintenance cover is done in order to change the attenuators or for connecting to a stinger connector (instead of the supplied connector).  1.  Loosen the six (6) M4 screws that hold the maintenance cover in place. Note: The screws are secured to the cover and will not fall off.  Figure 11: Removable Maintenance Cover   2.  Open the removable maintenance cover and let it hang on the attached safety cable. Note: Access to Attenuator(s) and test port are available via the Maintenance cover, see Figure 12.
AirStrand 1300 Installation Guide  DUG01370-SP Airspan Commercial and Internal Use  26  Figure 12: Maintenance Cover Open    Note: The “test port” is available for use to test required attenuation as needed.  5.2.3 Replacing the Maintenance Cover The following is the recommended procedure to set the maintenance cover in place and the correct pattern for tightening the screws to maintain proper weather proofing.  Note: Verify that the gasket is “seated” fully within the groove encircling the opening before setting the cover in place. 1.  Carefully place the maintenance cover (utilize the location pin) over the opening and hand tighten the six (6) M4 screws in place. 2.  Tighten the screws in the following pattern in order to achieve proper pressure for optimal weather proofing.
AirStrand 1300 Installation Guide  DUG01370-SP Airspan Commercial and Internal Use  27  Figure 13: Screw Tightening Pattern   Tightening the screw in this pattern reduces the likelihood of the cover shifting and flexing, which could nullify the weather proofing. When you’ve tightened all the screws, go back through the pattern again with the torque screwdriver to ensure that every screw is tightened appropriately. Caution: Initially hand-tighten the six (6) M4 screws. Torque the screws to no more than a maximum of 17.70 in-lbs or 2 N.m using a Torque screwdriver.
AirStrand 1300 Installation Guide  DUG01370-SP Airspan Commercial and Internal Use  28 A Job Sheet This job sheet enables the users to keep track of their installation. It covers all the prerequisites required for accomplishing the AirStrand 1300 installation.   Site Requirements  o  Cable Strand for installation identified o  Position on Strand identified o  Access restrictions (highway regulations, other services on pole, power pole) o  Method of reaching Strand positions (Bucket truck, Elevated work platform) o  Configuration programming details known o  All equipment items available at the installation site o  AirStrand 1300 unit o  Strand Mounting Kit Tool Requirements (For further information, see Verify the Tools.) o  9/16 inch wrench o  1/2 inch wrench o #10 (5/32) Allen wrench o  Torque screwdriver o  Philips screw driver o  Adjustable Wrench
AirStrand 1300 Installation Guide  DUG01370-SP Airspan Commercial and Internal Use  29 B  Installation Checklist During installation, review and perform all the steps on this checklist (in the given order). This checklist is meant for the person who performs the AirStrand 1300 installation. It includes the high–level steps involved in the installation process. Tip: To make sure you complete all the tasks, detach or print this checklist and use it as a job aid. After performing, check off each task.   Procedure Action Check If Performed Verify the prerequisites Verify site requirements. ☐ Verify safety requirements. ☐ Verify installation requirements. ☐ Assemble the strand bracket onto the unit Assemble the strand bracket on the AirStrand 1300 unit. ☐ Install AirStrand 1300 on the cable strand Fit and secure the AirStrand 1300 unit to the strand cable. ☐ Adjust the GPS bracket Extend the GPS bracket as required ☐ Connect to Infrastructure Connect the CATV cable to the factory installed Connector ☐
AirStrand 1300 Installation Guide  DUG01370-SP Airspan Commercial and Internal Use  30 C Abbreviations Term Definition 3GPP 3rd Generation Partnership Project, responsible for LTE ABS Almost Blank Subframe ACS Adjacent Channel Selectivity is a measurement of a receiver's ability to process a desired signal while rejecting a strong signal in an adjacent frequency channel. ACS is defined as the ratio of the receiver filter attenuation on the assigned channel frequency to the receiver filter attenuation on the adjacent channel frequency. AWGN Additive White Gaussian Noise is a channel model in which the only impairment to communication is a linear addition of white noise with a constant spectral density and a Gaussian distribution of amplitude. BER Bit Error Rate CN Core Network CP Cyclic Prefix CTC Convolution Turbo Code is a high-performance forward error correction (FEC) code dB Decibel. A logarithmic unit used to describe a ratio (such as power ratio in radio telecommunications) dBm An abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). It is used as a convenient measure of absolute power because of its capability to express both very large and very small values in a short form eNodeB Evolved Node B, is the element in E-UTRAN of LTE ESP Encapsulating Security Payloads (ESP) provide confidentiality, data-origin authentication, connectionless integrity, an anti-replay service (a form of partial sequence integrity), and limited traffic-flow confidentiality E-UTRAN Evolved UMTS Terrestrial Radio Access Network, is the air interface of 3GPP's Long Term Evolution EVM/RCE The Error Vector Magnitude or EVM (sometimes also called Receive Constellation Error or RCE) is a measure used to quantify the performance of a digital radio transmitter or receiver. It is measured in dB or percentage (%) – the lower the better FDD Frequency-Division Duplexing. A transceiver mode where the transmitter and receiver operate at different carrier frequencies GNSS Global Navigation Satellite System is a term used to describe a satellite navigation system with global coverage. There are currently two fully operational GNSSs – the US GPS and the Russian GLONASS. GTP-U GPRS Tunneling Protocol for User data is a relatively simple IP based tunneling protocol which permits many tunnels between each set of end points HPBW Half Power BandWidth is the angular separation in an antenna, in which the magnitude of the radiation pattern decreases by 50% (or -3 dB) from the peak of the main beam ICS In-channel selectivity is a measure of the receiver’s ability to receive a wanted signal at its assigned Resource Block locations in the presence of an interfering signal IPSec Internet Protocol Security is a protocol suite for securing Internet Protocol (IP) communications by authenticating and encrypting each IP packet of a communication session
AirStrand 1300 Installation Guide  DUG01370-SP Airspan Commercial and Internal Use  31 Term Definition LED Light Emitting Diode LTE Long Term Evolution MAC Medium Access Controller – responsible for several functions such Error Correction, Packet (De)Multiplexing, etc… MBSFN Multicast-Broadcast Single Frequency Network is an LTE feature designed to deliver services such as Mobile TV using the LTE infrastructure, and is expected to be a competitor to DVB-H-based TV broadcast MCS Modulation and Coding Scheme  MME Mobility Management Entity is the key control-node for the LTE access-network. It is responsible, among other things for idle mode UE tracking and paging procedure including retransmissions MTBF Mean Time Between Failures OFDMA Orthogonal Frequency-Division Multiple Access (OFDMA) is a multi-user version of OFDM digital modulation scheme, used for eNodeB transmissions to UEs PDCP Packet Data Convergence Protocol. A Sub-Layer in LTE responsible for IP Header (De) Compression, etc… PDU Protocol Data Unit PTP Precision Time Protocol is used to synchronize clocks throughout a network. In this document, PTP is referring to IEEE1588-2008 protocol RB Resource Block RLC Radio Link Control. A Sub-Layer in LTE responsible for Ack/Nack, error correction, packet reordering, etc… ROHS Restriction Of Hazardous Substances RRM Radio Resource Management is used to cover all functions that are related to the assignment and sharing of radio resources among UEs S-GW Serving Gateway. A Core entity in the LTE EPC architecture responsible for routing and forwarding user data packets, while also acting as the mobility anchor for the user plane during inter-eNodeB handovers and as the anchor for mobility between LTE and other 3GPP technologies SC-FDMA Single-Carrier FDMA is a frequency-division multiple access scheme, dealing with the assignment of multiple users to a shared communication resource. Used in LTE for UE transmissions to the eNodeB SCTP Stream Control Transmission Protocol is a reliable transport layer protocol, ensuring in-sequence transport of messages with congestion control like TCP SDR Software Defined Radio WEEE Waste Electrical and Electronic Equipment