Advanced Card Systems ACR1252U-A ACR1252 User Manual

Advanced Card Systems Limited ACR1252 Users Manual

Users Manual

   info@acs.com.hk 2013-2-21  www.acs.com.hk Page 1 of 7 ACR1252 Test Operating Procedure 1.  Driver installation Procedure 2.  Testing Environment Setup 3.  Testing Procedure  Driver installation Procedure Hardware requires:    ACR1252   PC with OS windows XP or above Software requires:   Driver “ACS_Unified_PCSC_Driver-4.0.0.0.rar” Steps: 1.  Extract the file “ACS_Unified_PCSC_Driver-4.0.0.0.rar” 2.  Run “Setup.exe”  3.  Click OK, then “Next>”
   info@acs.com.hk 2013-2-21  www.acs.com.hk Page 2 of 7  4.  Click “Next>”, and install finished:  5.  Driver Installation Complete
   info@acs.com.hk 2013-2-21  www.acs.com.hk Page 3 of 7 Testing Environment Setup Hardware requires:    ACR1252 x 1   PC with OS windows XP or above   Test card x 1 (provided by ACS) Software requires:   APDU.exe Steps: 1.  Plug in the reader into the PC 2.  Place the Test Card on the top of the reader about 1.5cm Open “APDU.exe”
   info@acs.com.hk 2013-2-21  www.acs.com.hk Page 4 of 7 3.  Select “T1”, “Stress”, Message = “FF CA 00 00 00”, Interval = “500”  4.  Press “Connect” 5.  Complete the Testing Environment Setup  Testing Procedure Hardware requires:    ACR1252 x 1   PC with OS windows XP or above   Test card x 1 Software requires:   APDU.exe Steps: 1.  Complete Testing Environment Setup procedure 2.  Press “Transmit” to start the testing
   info@acs.com.hk 2013-2-21  www.acs.com.hk Page 5 of 7  3.  The below will be shown  4.  Can start to Lab Test
   info@acs.com.hk 2013-2-21  www.acs.com.hk Page 6 of 7 Appendix A.  Parameter sheet Device ACR1252 Smart Card Reader Power supply Supply voltage................................ Regulated 5V DC Supply current................................ <200mA  (without smart card) Universal Serial Bus Interface Type ............................................... USB, four lines: +5V, GND, D+ and D- Connector ...................................... supplied together with the reader Speed............................................. Full Speed Device, 12 Mbps Contact Smart Card Interface Standard ........................................ ISO 7816 1/2/3, T=0 and T=1 Supply current................................ max. 50mA Smart card voltage ......................... 5V / 3V  Smart card read / write speed ........ 9600 – 307kbps Short circuit protection  .................. +5V / GND on all pins CLK frequency ............................... 3.6 MHz Card connector............................... SIM Connector Contactless Smart Card Interface Standard............................................. ISO 14443 A & B Parts 1-4, ISO18092 Protocol.............................................. ISO14443  T=CL  for  ISO14443-4  compliant  cards  and  T=CL  Emulation  for  MIFARE 1K/4K, ISO 18092 FeliCa and NFC tag Smart card read / write speed............... 106 kbps, 212 kbps, 424 kbps  Operating Frequency for Contactless Cards Access Operating Frequency............................ 13.56 MHz Antenna Antenna Size ........................................ 50mm x 40mm Operating distance ............................... up to 50 mm (Depend on Card Type) Built-in peripherals Monotone buzzer Bi-Color LED Case Dimensions ....................................98 mm (L) x 65 mm (W) x 12.8 mm (H) Color .............................................. Black Operating Conditions Temperature...................................-20 - 55° C Humidity ......................................... 10% - 80% Cable Connector Length .................................................. 1.5m (USB) Comment [u1]: Modify arranging to actual value
   info@acs.com.hk 2013-2-21  www.acs.com.hk Page 7 of 7 Standard/Certifications  CE, FCC,VCCI, N-Mark OS Windows 2000, XP and up Mac 10.5 and up  Linux  Android 3.1 and aboveOEM OEM-Logo possible, customer-specific colors, casing, and card connector   Revision History Date  By  Changes  Version 2013-12-20  Edmond Ho  •  First Release  1.00          FCC Caution:  Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's    authority to operate the equipment.  This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including    interference that may cause undesired operation.