Ademco 8DL6160RF-2 Security Transceiver / Keypad User Manual K0903V1 E 6160RF ii

Honeywell International Inc. Security Transceiver / Keypad K0903V1 E 6160RF ii

Users Manual

 K0903V1   2/06   Rev. E  ADEMCO 6160RFADEMCO 6160RFADEMCO 6160RFADEMCO 6160RFKeypad/TransceiverKeypad/TransceiverKeypad/TransceiverKeypad/TransceiverInstallation and Setup GuideInstallation and Setup GuideInstallation and Setup GuideInstallation and Setup Guide     GENERAL INFORMATION The ADEMCO 6160RF keypad/transceiver is a combination unit that combines the functions of the following devices: • 6160 Alphanumeric Addressable Keypad • 5881H RF Receiver • 5800TM Transmitter Module The 6160RF Keypad/Transceiver may be used on any control panel that supports 5800 Series wireless devices (e.g., VISTA-10P, VISTA-15P, and VISTA-20P). FEATURES • Supports wireless key transmitters (e.g.; 5804) and bi-directional transmitters (e.g.; 5804BD, 5828/5828V). • Supports wireless keys with high-security (encryption) capability (e.g.; 5804E, 5834-4). • Provides a nominal range of 200 feet for RF transmitters (some transmitters have a shorter range). • Supports RF jam detection when the receiver is enabled. • Capable of sending status signals (Armed, Ready, etc.) to bi-directional units such as 5804BD, 5804BDV and 5828/5828V. UUUULLLL The following 5800 series transmitters are not intended for use in UL installations: 5802, 5804, 5804BD, 5804BDV, 5804E, 5814, 5819, 5819BRS, 5819WHS, and 5828/5828V.  INSTALLING THE 6160RF Locate the 6160RF in an area and at a height where it is convenient for user operation. The 6160RF must be at least 10 ft from the control panel to ensure proper operation of the RF receiver. Mounting and Wiring The 6160RF has terminal blocks for connection to power and data wires. Removing the keypad’s case back provides access to the terminal blocks. The 6160RF can be surface mounted directly to walls, or to a single- or double-gang electrical box. Follow these steps to mount and wire the keypad: 1.  Push the two case release snaps at the bottom of the keypad with the blade of a medium screwdriver (this will push in the release snap), then pull that side of the case back away. Insert the screwdriver in the side of the keypad (between the front and back case) and gently twist to release the side locking tab. Repeat for the other side. Refer to Figure 1 for location of the case back release snaps and locking tabs. ARMEDREADYMOUNTINGRELEASESNAPSNOTE:TO REMOVE REAR COVERPUSH IN THE TWO MOUNTINGSNAPS LOCATED ALONG THE BOTTOM OF THE KEYPADAND LIFT COVER UP.6160RF-003-V1LOCKINGTA B Figure 1.  Removing the Case Back 2.  Pass the wiring from the control panel through the opening in the case back. (see the control panel’s instructions for proper run lengths.)  a.  If surface wiring is being used, wiring may be routed through the top or the bottom left-side breakout in the case back. The breakouts must be punched out using a screwdriver before mounting the case back.  b.  If desired, wires may be strain-relieved to the wire tie point on the inside of the case back with a tie wrap (not supplied). 3.  Mount the case back to a wall or to an electrical box using the 25mm-long self-tapping screws supplied (mollies for drywall are not supplied).  4.  Connect the power and data wires from the control panel to the terminals on the 6160RF as indicated in Figure 2 and Table 1.  G6160RF-002-V1Y+WIRING TERMINALS(TO CONTROL PANEL)++++ Figure 2 - 6160RF Wiring Details  FCC  /  IC  AGENCY STATEMENTS  ARE       ON PAGE 4
  - 2 - Table 1 - Wiring Table Keypad Control Panel Wire Color G▼ (Data Out) Data In Green - -Aux Pwr (GND) Black + +Aux Pwr Red ▲Y (Data In) Data Out Yellow  5. Reattach the keypad to the mounted case back. Attach the top of the keypad first, and then press the bottom section down until it snaps into place securely. 6.  Peel off protective film on the LED panel and install the keypad labels as required.   APPLICATION GUIDELINES FOR THE 6160RF Use the following guidelines when planning an installation:  If… And… Then… This is the only transceiver on the system, You want to use both the receiver and transmitter function on a single-partition system, • Set the keypad to a device address assigned to the desired partition.* • Enable the receiver. • Program a system House ID in the control panel (this will enable the transmitter function).** • Set the wireless devices that will communicate with this 6160RF to the same system House ID. You want to use only the transmitter function on a second partition, • Set the keypad to a device address assigned to the desired partition.* • Disable the receiver. • Program a DIFFERENT House ID in the 6160RF than is programmed in the control panel.*/ ** • Set the wireless devices that will communicate with this 6160RF to the same House ID as the 6160RF. There is another receiver or transceiver on the system,  You want to use only the transmitter function on a single-partition system, • Set the keypad to a device address assigned to the Partition 1. • Disable the receiver. • Program a House ID in the 6160RF that matches the system House ID programmed in the control panel.*  • Set the wireless devices that will communicate with this 6160RF to the same House ID.  Notes: * On VISTA-40 panels and above, wireless keypads (e.g., 5804BD) can only be used on a single partition.  This partition is programmed in field 1*48, and must match the partition assigned to the 6160RF.  Wireless keys can be used on more than one partition, using a House ID programmed in the 6160RF and the devices.  In this case, the wireless keys must be assigned to the same partition as the 6160RF.  ** On VISTA-20P panels, the 6160RF will use the House ID programmed in the panel for the partition to which it is assigned.  Wireless keypads can only be used on Partition 1.  PROGRAMMING THE 6160RF  Refer to the following procedure to program the 6160RF:  STEP DESCRIPTION  DISPLAY  CHOICES 1.  Enter the program mode by pressing the [1] and [3] keys simultaneously for a few seconds within 60 seconds after applying power.      2.  (Keypad Address) Enter the two-digit keypad address. Press the [✻] key to continue. Notes:  (1)  Refer to the control panel’s installation instructions for the acceptable keypad addresses.     (2) On the VISTA-40 and above the 6160RF’s partition assignment must match the RF keypad partition assignment programmed in field (1*48). CON ADDRESS  CON ADDRESS  CON ADDRESS  CON ADDRESS  =  XX XX XX XX    00-31 3.  (Receiver Enable) Enter [1] to enable, or [0] to disable Receiver. Enable the receiver if RF transmitters or wireless keypads are programmed into the control and no other receivers are enabled. Press the [✻] key to continue. RECEIVERRECEIVERRECEIVERRECEIVER    ON   [0ON   [0ON   [0ON   [0=  OFF] OFF] OFF] OFF] 1= ON 0 = OFF
  - 3 -  STEP DESCRIPTION DISPLAY CHOICES 4.  (Receiver Address) If receiver is enabled, enter the two-digit receiver address. (00-30). Note:  Refer to the control panel’s installation instructions for the acceptable receiver addresses. Press the [✻] key to continue. REC ADDRESSREC ADDRESSREC ADDRESSREC ADDRESS= XXXXXXXX 00-30 5.  (House ID) This prompt will only appear if the receiver is disabled. If the receiver is enabled the 6160RF will use the House ID programmed in the panel. Refer to Application Guidelines section when selecting a House ID. To program a House ID: Enter 01-31. To disable the transmitter: Enter 00 Note:  Each device that will receive status from the 6160RF must be set to the same House ID as the 6160RF (refer to Application Guidelines section). Press the [✻] key to continue. HOUSE  ID  HOUSE  ID  HOUSE  ID  HOUSE  ID  =  XX XX XX XX    00-31   6.  (Enable High Security Mode) Enter [1] to select High Security Mode. Note:  If the High Security mode is enabled, the 6160RF will only recognize encrypted devices. If this mode is disabled, the 6160RF will process commands both encrypted and non-encrypted devices.  Press the [✻] key to continue. HIGH SECURITYHIGH SECURITYHIGH SECURITYHIGH SECURITY    OFF  [1OFF  [1OFF  [1OFF  [1]]]]    = ONONONON    1= Enable 0 = Disable 7.  (Disable High Security Devices) Press the [✻] key to skip this prompt and exit Program Mode. Notes:  (1) The [✻✻✻✻] key must be pressed several times in order to save the programmed data.   (2) If you need to disable encrypted devices, refer to the Disabling High Security Devices section. DISABLE  HS DEV?DISABLE  HS DEV?DISABLE  HS DEV?DISABLE  HS DEV?    NO  [1NO  [1NO  [1NO  [1]]]]    = YESYESYESYES    1= YES 0 = NO  ACTIVATING HIGH SECURITY DEVICES This following procedure should be followed if using High-Security (encrypted) devices. STEP DESCRIPTION 1.  Follow the normal procedure for programming the device into the control panel (refer to the Installation Instructions for the device that you are programming). Exit out of Programming Mode. 2.  Put the control panel in Go/ No Go Test mode. (See the Installation Guide for the panel being installed.) 3.  Follow the instructions supplied with each wireless device to enroll the device in High-security mode. After each device is enrolled the 6160RF will momentarily display “SECURITY DEVICE” along with the device number and its serial number. Note: The 6160RF will support a maximum of 8 devices. If you attempt to enroll additional devices the keypad will display “EXCEEDED NUMBER” “ALLOWED DEVICES”. DISABLING HIGH SECURITY DEVICES This mode gives you the ability to disable high security on all wireless keys that have been enrolled in the 6160RF. This is particularly useful if a user loses a wireless key.  Once high-security (encrypted) devices have been disabled, they will only operate if the 6160RF is set to listen to both encrypted and non-encrypted devices (programming step 6, above). To completely disable the devices, they must be deleted from the control panel.  STEP DESCRIPTION DISPLAY CHOICES 1. After the keypad has been powered for at least 60 seconds hold down the [1] and [3] keys at the same time for 3 seconds. The current keypad address will be displayed. (You cannot change the keypad’s address at this point.) Press the [✻] key to continue. CON ADDRESSCON ADDRESSCON ADDRESSCON ADDRESS=XXXXXXXX    00-31 2.  (Delete High Security Devices) Press the [1] key to remove all high-security (encrypted) devices. Press the [✻] key to continue. DISABLE  HS  DEV?DISABLE  HS  DEV?DISABLE  HS  DEV?DISABLE  HS  DEV?    NO   [1NO   [1NO   [1NO   [1]]]]=YESYESYESYES 1= YES 0 = NO 3. If YES was selected in Step 2 the unit will display a confirm request to delete the stored high security device. Press the [1] key to accept, followed by the [✻] key to exit the programming mode. ARE  YOU  SURE?ARE  YOU  SURE?ARE  YOU  SURE?ARE  YOU  SURE?    NO   [1]NO   [1]NO   [1]NO   [1]=YESYESYESYES 1= YES 0 = NO
  TROUBLESHOOTING The error messages listed in the following table cause the 6160RF to produce a single ding tone. The table describes the error messages and the corrective actions. Display Probable Cause Corrective Action Low Bat (with zone no.) Low battery in the wireless device. 1. Replace the battery if the wireless transmitter has a replaceable battery. 2.  Replace the transmitter if the wireless transmitter does not have a replaceable battery. Open Ckt No data is being received from the control panel. Verify that the keypad ▲Y (yellow) wire is connected properly. Check 100 Check 1xx*  1. The control panel does not see the 6160RF Receiver, or the Receiver is not functioning.  2. Another device on the keypad terminals is not communicating to the control panel. 1a. Verify that the keypad ▲Y (yellow) and G▼  (green) wires are connected properly. 1b. Verify that the control’s receiver address is correct. 2.  Verify the wiring connections between the control and all other devices.  *xx= the device address of the receiver.  SPECIFICATIONS Physical:  5-3/8” H x 7-3/8” W x 1-1/4” D   (137mm x 187mm x 32mm) Wiring:  Refer to Table 1 Range:  200 ft (60.9 m) nominal Frequency:  345 MHz  Current:  Standby   50mA Backlighting on and Sounder on  150mA Display:  2 x 16 alphanumeric supertwist LCD, backlit Sounder:  Tone Generator Integrated Circuit. (fire alarm is loud pulsing tone; burglary/audible panic alarm is continuous tone) FOR DETAILS ON THE LIMITATIONS OF THE ENTIRE ALARM SYSTEM, REFER TO THE INSTALLATION AND SETUP GUIDE FOR THE CONTROL PANEL BEING INSTALLED IN CONJUCTION WITH THIS DEVICE.  FEDERAL COMMUNICATIONS COMMISSION STATEMENTS The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual.  Unauthorized changes or modifications could void the user's authority to operate the equipment.  CLASS B DIGITAL DEVICE STATEMENT This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your information: This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • If using an indoor antenna, have a quality outdoor antenna installed. • Reorient the receiving antenna until interference is reduced or eliminated. • Move the radio or television receiver away from the receiver/control. • Move the antenna leads away from any wire runs to the receiver/control. • Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different branch circuits. • Consult the dealer or an experienced radio/TV technician for help.  INDUSTRY CANADA CLASS B STATEMENT This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.  FCC/IC STATEMENT This device complies with Part 15 of the FCC Rules, and RSS210 of Industry Canada. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS 210 des Industries Canada. Son fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer d' interferences nuisibles. (2) Cet appareil doit accepter toute interference reçue y compris les interferences causant une reception indésirable.   WARRANTY INFORMATION  For the latest warranty information, please go to:  http://www.security.honeywell.com/hsc/resources/wa                                              ‡K0903V1?Š    K0903V1   2/06  Rev. E   2 Corporate Center Drive, Suite 100P.O. Box 9040, Melville, NY 11747Copyright © 2011 Honeywell International Inc.www.honeywell.com/security

Navigation menu