Ademco 8DL5870API1 Wireless Indoor Asset Protecction Device User Manual K14379V3 ii

Honeywell International Inc. Wireless Indoor Asset Protecction Device K14379V3 ii

Users Manual

K14379V3  7/11  Rev. A  5555870API870API870API870API    Wireless Indoor Asset Protection DeviceWireless Indoor Asset Protection DeviceWireless Indoor Asset Protection DeviceWireless Indoor Asset Protection Device    INSTALLATION AND SETUP GUIDE QUICK INSTALLATION Peel hereStep 1. Select LocationStep 2. Select Operating Mode (refer to table 1)Step 5.Test SystemStep 3. Program Device  (refer to Programming Section)1-3 Seconds30 OPaintingJewelry BoxLOOP 3LOOP 3LOOP 3LOOP 2LOOP 14. Press down firmly for 5 sec.3. Rotate into positionStep 4. Install DevicePaintings ComputersGun Case/Safe Large ScreenTV2.   Enter Zone Number, Zone Type,      Input Type at Keypad      Enroll Serial Number      (press tamper switch)      Enter Loop Number at Keypad      (use Loop 2 unless Fast Trigger      or Tilt is required) 30OMOUNT HORIZONTALLY ONLY (LOOP 3 ONLY)NORMALFAULT30OORJewelryBoxAvoid sources of vibration (i.e. speakers, fans, motors)Choose a stable, clean, flat surfaceMount in an inconspicuous area. 2. Peel tape backing before    installing. Place onto asset.High Security (Fast Trigger) Mode (Loop 1)Standard Security Mode (Loop 2) Tilt Mode (Loop 3)5-8 SecondsLarge ScreenTV(Asset)MountingSurfacePULL TO CONNECT BATTERY Pull tabTABSENSORGreater than 30O1. Clean mounting surface   (refer to mounting notes)ValuablesLOOP 1 is for High Security (Fast Trigger) applications and should ONLY be used if the asset will NOTbe subject to external vibration. Loop 2 (Standard Security mode) should be used in most cases.1. Pull tab to activate battery  PLEASE SEE BOTTOM OF PAGE 2 FOR FCC / IC AGENCY STATEMENTS
 - 2 - GENERAL INFORMATION 5870API  is  a wireless, supervised  asset  protection  device that is  compatible with systems that support 5800 series devices.  When  affixed  to  a  high-value  asset,  the  device will  trigger  an  alarm  if  an  attempt  is  made  to  move  or disturb the asset. ULULULUL    For commercial applications, the 5870API must be used in conjunction with the 5881ENHC receiver and compatible control panel.   5870API is for use on objects that do not move frequently or vibrate. Mounting the sensor near sources of vibration may cause false alarm conditions to occur. OPERATING MODES 5870API provides three programming options (loops).  • High Security (Fast Trigger) Mode (Loop 1)  • Standard Security Mode (Loop 2)  • Tilt Mode (Loop 3)   Loop 1 is for high security applications and should ONLY be used if the asset will NOT be subject to external vibration.  Loop 2 (Standard Security mode) should be used in most cases. Selecting the Operating Mode Table 1 provides a list of 5870API’s various operating modes, with the respective Loop numbers for each. Tamper Supervision 5870API’s tamper supervision feature (Loop 4) causes a trouble signal to be sent to the control if the sensor is removed from the asset being protected or if the unit’s cover is removed from the base.  The tamper switch is also used to program the unit’s serial number and loop assignments in the control panel.  OPERATION Installer Test Mode- Upon initial battery power up, the unit will transmit each time it is faulted or restored, which enables you to enroll and test the device. After the sensor transmits its first supervisory message (about 70-80 minutes after power-up), it switches to normal mode. Normal Mode - In normal mode there is a 3-minute lockout between transmissions, to help conserve battery life. To return to the installer test mode, remove and reinstall the battery.   Before enrolling the device, perform the following: 1. Remove the “PULL TO CONNECT BATTERY” tab This will allow the device to transmit. For additional transmissions, move or rotate the sensor. When the battery is connected the sensor powers up in the installer test mode. In this mode the sensor transmits fault and restore messages on all loops when it detects motion (or lack thereof). ULULULUL    When configured for use with the UL approved control panels (refer to UL Approved Compatible Control Panel list), the panel must be programmed not to transmit off-premises for the 5870API  zone only. PROGRAMMING Each transmitter has its own unique serial number, assigned during manufacture, which must be “enrolled” in the control panel before the device can be used with the system.   Please  refer  to  the  control  panel’s  installation instructions for details on device enrollment.  Please note that you must program a separate zone for each loop you are using on the transmitter.    If the asset being protected will not be moved under normal circumstances (i.e., a painting), it can be programmed as a 24 hour zone type. If the asset will occasionally be moved when the system is disarmed, it can be programmed as a perimeter zone type.  MOUNTING  The 5870API is mounted directly to the asset being protected via 3M VHB double-sided tape. The device should be mounted in an inconspicuous place on the asset. Refer to Mounting Notes section for additional information.   When installing the 5870API, select an area on the asset that is stable, clean and flat. Avoid areas that are subject to vibration (i.e.; speaker grills) When using Loop 3 the device must be mounted horizontally. 1. Determine the optimum mounting location taking care to avoid damp locations. To maximize the transmitter’s range, avoid mounting the device to metal objects, if possible. 2. Temporarily mount the device to the asset to be pro-tected using masking tape or any suitable method. 3. Before the transmitter is permanently mounted, conduct Go/No Go tests (refer to the Control Panel’s instructions) to verify adequate signal strength from the mounting location. 4. Always verify range by holding the sensor in the approximate mounting location and moving the asset. The panel (in test mode) should respond to the trans-missions. If not, move the asset sensor to a more suitable mounting location. 5. Remove the tape backing paper and firmly press the sensor in the desired mounting location. Apply firm pressure for 5 seconds. 6. Verify operation by moving the asset. Always check the alarm panel keypad to verify that the zone has tripped.Table 1 - 5870API Operating Mode Choices *   Response time will be affected by the type of motion (walking, running, dropping, etc.) as well as other tasks being processed by the panel. Operating Mode  Loop  Faults when…  Restores when… High Security (Fast Trigger) Mode - Short Travel Time, minimum movement detection 1  Asset/sensor is moved for 1-3  seconds (typical)* Motion of the asset/sensor has stopped for 3 seconds*. Standard-security Mode - Long Travel Time, occasional movement detection 2  Asset/sensor is moved for 5-8  seconds (typical)*  Motion of the asset/sensor has stopped for 3 seconds*. Tilt Mode - Intended for boxes with lids that can be opened (e.g.; jewelry or cash boxes). 3  Asset/sensor is tilted >30 degrees (+/-10)  (with respect to the horizon) Asset/sensor is tilted <15 (+/-5) degrees (with respect to the horizon).
 - 3 - REPLACING THE BATTERY 5870API is powered  by  a 3-volt lithium battery.  If the battery voltage gets too low, the device sends a low battery signal to the control panel. The 5870API consumes less battery power when stationary than when in motion. Maximum battery life will be obtained when used on assets that are moved infrequently (e.g.; televisions, paintings, sculpture, etc.)  Replace the battery with Ademco 469, Panasonic CR2 or Duracell DLCR2. Use of another battery may present the risk of fire or explosion 1.  Using a screwdriver, release the case’s retaining tabs. 2.  Carefully remove the sensor’s cover. (see Figure 1) 5870API-005-V0INSERT TIP OFSCREWDRIVER.PUSH IN TORELEASE CLIP Figure 1 – Replacing the 5870API Battery 3.  Check the battery polarity orientation before installing (see Figure 2). 4.  Insert the battery securely in the sensor. 5.  Snap the sensor cover back in place. 5870API-001-V0 Figure 2 – Replacing the 5870API Battery MOUNTING NOTES ULULULUL    3M VHB double –sided tape can be used on the following surfaces: acrylic, polycarbonate, coated polycarbonate, cellulose acetate butyrate, aluminum, acrylic/polyurethane paint, galvanized, stainless and enameled steel, rigid PVC,  epoxy, polyester and epoxy polyester paint, uncoated and silane coated glass, glass epoxy, polybutylene terephthalate, nylon, noryl (PPE) polyphenelene ether, and acrylonitrile butadiene styrene. Note: Most consumer electronics with plastic cases are manufactured from acrylonitrile butadiene styrene (ABS).  1.  To obtain proper performance with adhesive tapes, it is important to ensure that the surfaces are dry and free of grease and condensed moisture. Clean the area where the sensor will be installed with a 50/50 mixture of water and isopropyl alcohol, and allow to dry. 2.  Replace the adhesive when relocating the device. Take care to align the hole in the tape with the device’s tamper switch plunger. Additional mounting tape squares are available in packs of 10; 5870APITAPE-B general application tape. 3.  Firm application pressure develops better adhesive contact and helps improve bond strength, which is achieved after 72 hours. 4.  If using Loop 3 the device must be mounted horizontally.   • 5870API is not watertight, and therefore should not be used in damp locations.  • The device should not be installed in locations where temperatures may drop below 14° F.   • 5870API is not intended for use on swinging doors.  SPECIFICATIONS Dimensions: 1.8" H x 1.7" W x 0.63" D  (45.72 mm x 43.18 mm x 16.02 mm) Power: Single 3V Ademco  469,  Panasonic  CR2  or  Duracell  DLCR2  Lithium Battery Environmental Conditions: 14° to 122°F (-10° to 50°C) <90% RH (non-condensing)  5870API-003-V15870API(Rear View)1.8"1.7"TAMPER
UL APPROVED COMPATIBLE CONTROL PANELS The 5870API is compatible with the following commercial control panel families:  Vista-10P/10PCN/10PSIA, Vista-10SE/10SEADT/10ROSE, Vista-10P1PACK, Vista-10PASE Vista-15/15CN, Vista-15P/15PCN/ PSIA, Vista-15PMT, Vista-20BAY, Vista-20P/20PCN/20PBAY, Vista-20MT, Vista-20PS/20PSCN, Vista-20PSIA, Vista-20SE/-20HWSE, Vista-20AMT3, Vista-40, Vista-48C/48D, Vista-50P/50PADT, Vista-50PEN/50PENADT, Vista-128B,Vista-128BP/128BPADT, Vista-128FBP, Vista-250BP, Vista-250FBP, FA130CP/130CP-CN/130CPSIA, FA148C/148C-CN, FA148CP/148CP-N/148CPSIA, FA168C/168C-CN/168C-GP, FA168CPS/168CPS-CN/168CPSSIA, FA1660C, FA1670C, FA1700C, Safewatch Pro and Security Manager, Security Manager 2000, Safewatch Pro 3000/3000EN, Security Manager 3000/3000EN, Entrepreneur 3000EN, AFA15P, CFV15P/PCN, AM100, V-10SE/WT, V10SMITH, V10SELECT, V12C, 250-P1, 300P1, 320P1   WARNING Risk of fire, explosion, and burns. Do not recharge, disassemble, heat above 212° F (100° C) or incinerate. Dispose of used batteries properly. Keep away from children. TO THE INSTALLER Regular  maintenance  and  inspection  (at  least  annually)  by  the  installer  and  frequent  testing  by  the  user  are  vital  to continuous satisfactory operation of any alarm system.   The installer should assume the responsibility of developing and offering a regular maintenance program to the user as well as  acquainting  the  user  with  the  proper  operation  and  limitations  of  the  alarm  system  and  its  components  parts.  Recommendations must be included for a specific program of frequent testing (at least weekly) to ensure the system’s proper operation at all times.    FEDERAL COMMUNICATIONS COMMISSION STATEMENT The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User’s Manual. Unauthorized changes or modifications could void the user’s authority to operate the equipment. FCC   IC STATEMENT This device complies with Part 15 of the FCC Rules and RSS 210 of Industry Canada. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation.   Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS 210 des Industries Canada. Son fonctionnement est soumis aux conditions suivantes : (1) Cet appareil ne doit pas causer d'interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçues, y compris les interférences causant un reception indésirable.  FCC ID: CFS8DL5870API1   IC: 573F-5870API1  IC MODEL: 5870API1         WARRANTY INFORMATION For the latest warranty information, please visit: www.honeywell.com/security/hsc/resources/wa   U.S. Patent Number 6,724,316 2 Corporate Center Drive, Suite 100P.O. Box 9040, Melville, NY 11747Copyright © 2011 Honeywell International Inc.www.honeywell.com/security  ÊK14379V3rŠ K14379V3  7/11  Rev. A

Navigation menu