 5800-OD Wireless Outdoor Motion Sensor –  Installation Instructions   GENERAL INFORMATION The Honeywell 5800-OD Wireless Outdoor Motion Sensor (referred to as the 5800-OD) combines the convenience of wireless technology with a full featured outdoor PIR motion sensor.  The major features are highlighted below:  Immunity to bright light disturbances from headlights, sunlight, and other bright light sources.  Very low current draw.  Discriminates both large and small animals to reduce false alarms.  Selectable detector range and angle.  Battery saving circuit allows for a 5 or 120 second period of inactivity before being reactivated.  Tamper detection.  SPECIFICATIONS Detection Method  Passive Infrared Initial Warm Up  ~ 2 minutes Mounting Height  0.8 - 1.2m (2.7 - 4ft) wall or pole   Range  Adjustable up to 12m (40ft) Pattern  90° pattern consisting of 13 zones.  This pattern can be adjusted in 15° incre-ments from center up to 45°.   Sensitivity  2.0° C at 0.6m/s (3.6° F at 2.0ft/s) Detection Speed  0.3 - 1.5m/s (1 - 5ft/s) Operating Voltage  6 VDC (uses 4 lithium 1.5VDC AA cells) Current  3mA max (during walk test) 10uA (standby) Battery Saving Timer  Adjustable 120sec or 5sec Alarm Period  ~ 2.5 seconds LED Indicator  Enabled during a walk test. Disabled for normal operation. Weatherproof  IP54 compliance Operating Temperature  – 20 to + 50 ° C (– 4 to +122° F) Humidity  95% Max Accessories (included)  Pole mounting kit, screw kit, detection masking strips.      INSTALLATION (refer to the Component Identification Diagram on page 5)  1   Select the Mounting Position  Avoid strong sunlight into the sensor's field.  Avoid moving or swaying trees and bushes.  Orient the detector so that intrusion passes across the detection field, not into the sensor.      Allow 110mm (4.4") above the sensor to enable  opening the cover.   Choose an installation height of 0.8m to 1.2m (2.7 to 4ft).    Ensure the sensor can be mounted on a perpendicular wall or pole that would make its detection pattern parallel to the ground.  Parallel  2   Prepare the Sensor for Mounting 1. Loosen the Captive Lock Screw and remove the Cover.  2. Remove the four (4) screws fastening the Detector to the Back Box.   3. Remove Detector from the Back Box.    3   Install / Replace the Battery IMPORTANT:  Use only lithium batteries.  Use four (4) lithium 1.5VDC AA cells.  (Energizer L91 or equivalent.)  Observe polarity.  Mark the date of replacement on the batteries. 1. If necessary, loosen the Captive Lock Screw and lift Cover off.  Then, remove 4 screws that secure the Detector to the Back Box. 2. Observe the proper polarity and replace the batteries.  Ensure positive side of battery is pointing away from the springs. 3. For reference, mark the date of replacement on the batteries.     PLEASE GO TO PAGE 6 FOR FCC / IC STATEMENTS
 5800-OD Wireless Outdoor Motion Sensor –  Installation Instructions  – 2 –   4   Mount the Sensor WALL MOUNTING 1. Install the Back Box on the wall with the two T4 x 20 mounting screws. UP 2. Insert the batteries (see Install/Replace the Battery), then secure the Detector to the Back Box. 3. Fasten with four (4) screws.  4. Perform Settings & Adjustments. 5. Perform a Walk Test. 6. Secure the Cover with the Captive Lock Screw. POLE MOUNTING   1. Use a pole with an outside diameter of 43-48mm  (1.69-1.89").  2.7- 4ft.0.8 - 1.2m 2. Attach the Brackets to the Back Box with two M4 x 30 screws.    3. Using the Pole Brackets and four M4 x 30 screws, fasten the Back Box to the pole.  UP 4. Insert the batteries (see Install/Replace the Battery), then mount the Detector on the Back Box and fasten with four (4) screws. 5. Perform Settings & Adjustments. 6. Perform a Walk Test. 7. Secure the Cover with the Captive Lock Screw.  5   Perform Settings & Adjustments SET THE DETECTION LENGTH Note: The length of the lower detection area determines the detection length. The upper detection area stays parallel to the ground at all times.  The lower detection area can be adjusted as shown below by the switch position. Detection length is therefore limited by the length of the lower detection area since both upper and lower areas have to be blocked at the same time to activate the sensor. IMPORTANT:   This sensor detects temperature differences between the moving object and the background temperature in the detection area to produce a valid detection.    If the object does not move, the sensor will not detect it.  If there is traffic near the detection area, adjust the detection area length 1.5 to 2.0m (5 to 7ft) back from traffic. Detection Length  Detection Length  Detection Length  UPPER and LOWER beams are blocked, detection is made. Only the LOWER beam is blocked, detection is not made. Only the UPPER beam is blocked, detection is not made.
 5800-OD Wireless Outdoor Motion Sensor –  Installation Instructions  – 3 –  Press and slide the Detection Length Adjustment Switch to the desired position. ABCD   MAX DETECTION LENGTH POSITION  STANDARD ENVIRONMENTAL Á D  02.0m  (6.7ft)  1.5 - 2.5m  (5 - 8ft) C  05.0m  (16.7ft)  04 - 5.5m  (13 - 18ft) B  08.0m  (26.7ft)  06 - 10m  (20 - 33.3ft) A  12.0m  (40.0ft)  10 - 15m  (33.3 - 50ft) Á Detection length may vary due to environmental conditions.  Detection height = 1m (3.3ft)  SET THE DETECTION AREA ANLGLE 1. The detection area angle is 90° with 7 fingers as shown.  90o45o45o  Top view01210551212010105(m)(m)45  AdjustableActive detectionfingers.o45  Adjustableo 2. Hold the sensor and turn it to the desired direction.  Each click represents 15° of change.  Adjust todesired direction IF NECESSARY, CONFIGURE DETECTION MASKING 1. Spread the Cover and gently press on the Lens to remove the Lens Holder.  2. Separate the Lens from the Cover.     CoverLensArea MaskingPlateLensHolder  3. Identify the segments on the Lens to be masked. 4. Then apply the adhesive Masking Strip(s), as necessary, inside the lens to cover the desired segments.  113234567891012111132345678910 1211 5. Replace the Lens by aligning the 4 cutouts on the lens to the 4 projections on the cover.  Snap in place with the Lens Holder.  CoverLens  6. Ensure the Lens Holder is held by the left and right cover prongs and the two tabs are engaged.    CoverLensHolder
 5800-OD Wireless Outdoor Motion Sensor –  Installation Instructions  – 4 – SET THE SENSITIVITY SET THE DIP SWITCHES  1. Set the Sensitivity Select Switch to the desired sensitivity. SensitivitySelect Switch(L,M,H)  Notes:    When greater sensitivity is desired, select "H".    When conditions are poor select "L". 1. Set switch 2 for the desired Battery Saving Timer period. Note: The alarm output activations are limited by the timer selection (5 or 120 seconds).  Even if there are continuous alarm events, the alarm output operates only once in the selected timer period.  This  can be 5 or 120 seconds. 120s – Default Setting 5s – Used when frequent alarm transmission is re-quired.  Battery life will be shortened when using this setting. 2. Set switch 3 for the desired Pulse Count (selectable for 2 or 4). Pulse Count of 2 = detection can be made with as little as two steps. Pulse Count of 4 = detection can be made with as little as four steps. 3. Set switch 1 to enable the Walk Test, see the instructions below. ON  1. Walk Test5s    2. Battery Saving Timer2      3. Pulse CountON123OFF120s4  6   Perform a Walk Test NOTE: With the Walk Test switch set to ON the LED will light when the detector is tripped, and the alarm is generated instantly. 1. Set the walk test switch (DIP switch 1) to ON.  Replace the cover. 2. Perform a walk test through the detection area, and verify satisfactory results. 3. Allow the detection area to remain static and check for false or unwanted detections.  4. If necessary, adjust the detection area (see Perform Settings & Adjustments). 5. Repeat the walk test through the detection area, and verify satisfactory results. 6. Set the walk test switch to OFF, and secure the Cover with the Captive Lock Screw. Notes:  If normal car or people traffic pass close to the detection area, adjust the detection area 1.5 to 2.0m (5 to 7ft) shorter to reduce false detections.  This also allows for changes due to environmental thermal conditions.  If the detection length is adjusted to position "A" [12m (40ft)], the detection area may increase when there is a big temperature difference between the moving object and the background.     If this causes a problem, adjust the detection length to position "B".  Then walk test to verify satisfactory results. Approx.8m (27ft)position BApprox.12m (40ft)   WALK TEST  This sensor has a multi-level detection pattern (from side view).  A heat source beyond the detection area may cause the detector to issue a false alarm by reflecting off the ground.  Examples include puddles, wet surfaces, very smooth asphalt or concrete surfaces.  If this causes a problem, adjust the detection length to position "B".  Then perform a walk test to verify satisfactory results.    7   Program the Control Panel Prior to use in the system, you must “enroll” the transmitter's serial number in the control panel.  Refer to the control panel’s instructions for further details.  During programming, the transmitter shall be treated as RF supervised .  (Mandatory for UL installations.)   TROUBLESHOOTING SYMPTOM CAUSE REMEDY Batteries are incorrectly installed or  dead. Check for correct battery installation, or replace dead batteries. No detection, when walking through the detection area. Wiring is faulty or loose.  Check all connectors and wiring.   Water in unit.  Check for cracks in the housing that would allow water infiltration.  Replace unit.   Transmitter or PIR sensor is faulty.  Replace unit. No detection occasionally, or poor detection. Sensitivity is set too low.  Try a higher sensitivity setting.   Detection area is not set correctly.  Perform a Settings & Adjustments procedure.  Low battery fault indicated on system keypad display.    Batteries are very low or dead.  Replace batteries.
 5800-OD Wireless Outdoor Motion Sensor –  Installation Instructions  – 5 – TROUBLESHOOTING SYMPTOM CAUSE REMEDY Alarms when no one is walking through the detection area. Sensor is not perpendicular to ground.  Remount and align sensor so the detection area is parallel to the ground.   Sensor is detecting moving trees, bushes, or a strong source of light. Check for moving trees, or bushes or a strong light source.  Perform a Settings & Adjustments procedure.    Lower detection area is too long.  Set Detection Length to a shorter range.   A heat source in the area may be causing an abrupt temperature change. Move or remove the heat source. Mask the area pointing to the source of heat, or shorten the Detection Length.    COMPONENT IDENTIFICATION   Mounting ScrewsT4 x 20 DetectorSensor(Do not touch)CoverLEDIndicatorCoverLensBack BoxM4 x 30 (4 places)CaptiveLock ScrewMasking Strip(Use as required)LensHolderUPDIP SwitchSensitivity SelectSwitch Detection LengthAjustment SwitchPoleBracket
 5800-OD Wireless Outdoor Motion Sensor –  Installation Instructions     USER NOTIFICATION The user shall not make any changes or modifications to the equipment unless authorized by the installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment.   LIMITATIONS OF THE PIR MOTION DETECTOR While the Intrusion Detector is a highly reliable intrusion detection device, it does not offer guaranteed protection against burglary.  Any Intrusion Detection device is subject to compromise or failure to warn for a variety of reasons: •  Passive Infrared Motion Detectors can detect intrusion only within the designed ranges as diagrammed in this installation manual. •  Passive Infrared Motion Detectors do not provide volumetric area protection.  They do create multiple beams of protection, and intrusion can be detected only in unobstructed areas covered by those beams. •  Passive Infrared Detectors cannot detect motion or intrusion that takes place behind walls, ceilings, floors, closed doors, glass partitions, glass doors, or windows. •  Mechanical tampering, masking, painting, or spraying of any material on the lenses, windows or any part of the optical system can reduce the detection ability of the Passive Infrared Motion Detector. •  Passive Infrared Detectors sense changes in temperature; however, as the ambient temperature of the protected area approaches the temperature range of 90° to 105°F (32° to 40°C), the detection performance can decrease. •  This Passive Infrared Detector will not operate without the appropriate battery installed, or if the battery is weak or improperly connected (i.e., reversed polarity). •  Passive Infrared Detectors, like other electrical devices, are subject to component failure.  Even though this equipment is designed to last as long as 10 years, the electronic components in it could fail at any time. We have cited some of the most common reasons that a Passive Infrared Motion Detector can fail to catch intrusion.  However, this does not imply that these are the only reasons, and therefore it is recommended that weekly testing of this type of unit, in conjunction with weekly testing of the entire alarm system, be performed to ensure that the detectors are working properly. Installing an alarm system may make the owner eligible for a lower insurance rate, but an alarm system is not a substitute for insurance. Homeowners, property owners and renters should continue to act prudently in protecting themselves and continue to insure their lives and property. We continue to develop new and improved protection devices.  Users of alarm systems owe it to themselves and their loved ones to learn about these developments.   FCC / IC STATEMENT This device complies with Part 15 of the FCC Rules, and RSS210 of IC. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation.   WARRANTY  For the latest warranty information, please go to: http://www.security.honeywell.com/hsc/resources/wa/                     To obtain applicable EU compliance Declaration of Conformities for this product, please refer to our Website,  http://www.security.honeywell.com/hsce/international/index.html.  For any additional information regarding the compliance of this product to any EU specific requirements, please contact:  Quality Assurance Department, Honeywell Security & Custom Electronics, Newhouse Industrial Estate Motherwell, Lanarkshire ML1 5SB, Scotland, United Kingdom. Tel:  +44(0)1698 738200 Email:  UK64Sales@Honeywell.     © 2008 Honeywell International Inc. Honeywell is a registered trademark of Honeywell International Inc.   All other trademarks are the properties of their respective owners.  All rights reserved. Please contact your local authorized Honeywell representative for product warranty information.       ÊPREK15009nŠ PREK15009  5/08  Rev. A  FCC & IC