Acon Biotech 001 On Call Bluetooth Adapter User Manual Manual

Acon Biotech (Hangzhou) Co., Ltd. On Call Bluetooth Adapter Manual

Manual

 On Call ® Bluetooth® Adapter User’s Manual (iOS) REF G124-15A English Welcome, and Thank you for choosing the On Call® Bluetooth® Adapter. On  Call® Bluetooth®  Adapter  uses  Bluetooth®  Core  Specification  version  4.0 technologies for rapid build-up of simple links. Bluetooth® 4.0 version aimed at very low power applications running off a coin cell with a long distance of data transfer. Our  On Call® Bluetooth® Adapter is intended for our On Call® Blood Glucose Monitoring System (BGMS) users who want to monitor their glucose levels remotely.  In this  manual The  On Call®    Bluetooth® Adapter provides a wireless  Bluetooth®  connection  between  your  Apple  iOS  mobile  device  and your On Call® BGMS. So you can enjoy the comfortable and convenient data processing after blood glucose data transfer. Before using, read the instructions carefully.   Please  refer  to  user’s  manual  of On  Call®  BGMS  to  learn  about  all  the components this Bluetooth® Adapter works together.   Use only On Call® BGMS and Apple iOS mobile device  with the On Call®   Bluetooth® Adapter.   Keep out of reach of children.
 On Call® Bluetooth® Adapter Overview  BGMS and Device Compatibility On Call® BGMS: All On Call® meters with data transfer function. Compatible devices: Apple iOS mobile device: iphone4s, iphone5, itouch4s and itouch5 Replace the Battery One CR 2032 3.0V Coin Cell Battery has been preinstalled in the adapter. Please turn over the adapter and pull out the preinstalled insulation sheet to start use.   The Red indicator light will flash when the battery is low, it can be used for only very short time from then on, please replace the battery as soon as possible according to the following steps:
 1. Turn over the adapter and slide the battery cover off the adapter   2. Insert one CR 2032 3.0V coin cell battery into the battery carrier. Make sure it is aligned with the Plus (+) side facing up. 3. Slide the battery cover back on and make sure that it snaps shut.  Note: Your battery will last longer if you remove it when you will not be using your Bluetooth® Adapter for a month or longer. Warning: Only use Lithium CR 2032 3.0V coin cell battery. Using any other type of battery may cause an explosion. Using your On Call® Bluetooth® Adapter The On Call®   Bluetooth® Adapter is designed to be simply operated with only one control button. Button will provide alternative operations depending on the color and the duration of the time they it is pressed. 1. Turning the Bluetooth® Adapter on and off To turn the adapter on, press the button briefly. The On Call® Bluetooth® Adapter will shut itself off automatically after finishing the data transmission or 2 minutes after last action. 2. Pairing with your mobile device Before you  can start using the Bluetooth® adapter, you need to connect it to your On Call® Blood Glucose Meter. 1) Inert the headphone plug of your Bluetooth® Adapter into the headphone jack of your On Call® Blood Glucose Meter.
  2) When the “PC” symbol appearing on screen of meter, it comes into data transmission mode.   Note: If the meter does not show “PC” symbol, please refer to the relevant User’s Manual of blood glucose meter and coordinate with meter buttons to display the “PC” symbol on the screen. 3) Press button to start the automatic pairing with Bluetooth® Adapter and iOS device. Warning: Connect On Call® Bluetooth® Adapter ONLY to On Call® BGMS. Connecting it to any other device may make your readings inaccurate or damage one or both devices. Do not touch the metal part of the headphone plug of the Bluetooth® Adapter by your hand.  3. Data transmission   1) After your iOS device finding and pairing with Bluetooth® Adapter, press command of “receiving data” in iOS interface.
  2) Meter is displaying “to” and “PC” to indicate the data transmission to Bluetooth® Adapter, when the Green indicator light on Bluetooth® Adapter flashes every 1 second. 3) When the Meter appears “End” and “PC” the pairing is complete. 4) The Bluetooth® Adapter is transferring date to iOS device when the Green indicator light of the    Bluetooth® Adapter flashes every 0.3 seconds.  Warning: Do not put the Bluetooth® Adapter on a metal surface or in a metal box or enclosure. This may affect its ability to send data. Indicator Light and Instruction Card Indicator light Work Mode Green indicator light flashes every 1 second Working mode Green indicator light flashes every 0.3 seconds Wireless transmission   Red indicator light flashes every 1 second Low battery Help Information Aconlab: ACON Laboratories, Inc. 10125 Mesa Rim Road San Diego, CA 92121, USA Web: http://www.acondiabetescare.com Phone: 1-858-875-8000 E-mail: DC.techsupport@aconlab.com.cn Adapter Use and Precautions 1. Always store your On Call® Bluetooth® Adapter with power off and safely protected.
 2. Keep your adapter dry and avoid exposing it to extreme in temperature, keep it away from heat and direct sunlight. Storage at high temperatures (above 45°C / 113°F) can degrade performance and reduce battery life. Storage at low temperatures (down to –10°C / 14°F) will shorten battery life and may affect operation. 3. Do not expose your On Call® Bluetooth® Adapter to water or other liquids. 4. Never operate this device in an area where there is a risk of explosion. Using electrical equipment in the presence of flammable anesthetics or oxygen may cause an explosion. 5. Do not take the adapter apart. Taking the adapter apart will void the warranty. Note: Follow proper precautions and all local regulations when disposing of the Adapter and used batteries. Maintenance Your On Call® Bluetooth® Adapter does not require special maintenance or cleaning. A cloth dampened with water and a mild detergent solution can be used to wipe the outside the adapter. Take care to avoid getting liquids, dirt, blood or control solution into the adapter.   On Call® Bluetooth® Adapter is a precision electronic instrument. Please handle it with care. Specifications Feature Specification Bluetooth® Version Version 4.0 ( Bluetooth® low energy) On/Off Source Lithium CR 2032 3.0V coin cell battery Transmission Range Range up to 10 m (33 feet) Transmission Data Time Less than 6 minutes Adapter Size 38*38*13mm Adapter Weight ≈16 g (Including battery) Storage Temperature -25~+55℃ Operating Temperature +5~+45℃ Operating Relative Humidity 10 ~90% (Non-condensing)
   Troubleshooting What’s wrong? Causes Solutions Green indicator light doesn’t come Battery is exhausted Change battery Cannot  pair  with your iOS device The  Bluetooth®  of  your iOS  device  is  not  in  the discoverable state 1.  Confirm  the  Bluetooth®  of your  iOS  device  is    in discoverable state 2.  Restart  the  Bluetooth®  of your iOS device. Red indicator flash Battery voltage is too low Change battery Data  cannot  upload from  Meter  to Bluetooth®. Connector  is  not connected  correctly  or improper  meter  type used. 1.  Reconnect the connector. 2.  Confirm  the  meter  type  is compatible. Certification and Safety Approvals FCC This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and  (2)  this  device  must  accept  any  interference  received,  including interference that may cause undesired operation. FCC Caution: To assure continued compliance, any changes or modifications   not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This equipment has been tested and found to comply with the limits for a Class B  digital  device,  pursuant  to  part  15  of  the  FCC  Rules.  These  limits  are designed  to  provide  reasonable  protection  against  harmful  interference  in  a residential installation. This  equipment generates uses and can radiate radio frequency  energy  and,  if  not  installed  and  used  in  accordance  with  the instructions,  may  cause  harmful  interference  to  radio  communications. However, there is no guarantee that interference will not occur in a particular installation.  If  this  equipment  does  cause  harmful  interference  to  radio  or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of
 the following measures: •  Reorient or relocate the receiving antenna •  Increase the separation between the equipment and receiver •  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected •  Consult the dealer or an experienced radio/TV technician for help The  user  must  place  the  distance    (20cm)  or  more  from  any  personnel  in order to comply with FCC RF exposure requirements. FCC ID: 2AA3K001     CE This product is CE marked according to the provisions of the R & TTE Directive (1999/5/EC). Hereby,  ACON declares that this product is in compliance with the  essential requirements and other relevant provisions of Directive 1999/5/EC. For further information please consult http://www.acondiabetescare.com Please note that this product uses radio frequency bands not harmonized within EU.   Bluetooth® The    Bluetooth® word mark and  logos  are  owned by the  Bluetooth SIG, Inc. and any use of such marks by ACON is under license. Other trademarks and trade names are those of their respective owners. Bluetooth QD ID BXXXXXX REFERENCES   Number: XXXXXXXXXX  Effective Date: 2013-XX-XX
 Warranty  Please complete the warranty card that came with this product and mail it to your local distributor to register your purchase. If the adapter fails to work for any reason other than obvious abuse within the first one (1) years from purchase, we will replace it with a new adapter free of charge. For your records, also write the purchase date of your product here. Date of purchase: _______________________________________________ Note:   i.  This warranty applies only to the adapter in the original purchase, and does not apply to the battery supplied with the adapter. ii.  Changes made to the product, unless expressly approved by ACON could void the user’s license for and the warranty of the device.