ASSALOY YRHCPZW0 Yale Real Living Electronic Zwave Lock User Manual 12 0002 Exhibit Cover

ASSA ABLOY Inc. Yale Real Living Electronic Zwave Lock 12 0002 Exhibit Cover

Manual - YRD210-ZW

    5015 B.U. Bowman Drive  Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598   Certification Exhibit     FCC ID:  U4A-YRHZPZW0 IC: 6982A-YRHZPZW0  FCC Rule Part: 15.249 IC Radio Standards Specification: RSS-210  ACS Project Number:  12-0002   Manufacturer: Assa Abloy Inc. Models: YRD220-ZW, YRD210-ZW, YRT210-ZW, YRT220-ZW     Manual – YRD210-ZW
Yale Real Living™ Push Button DeadboltInstallation and Programming InstructionsFor Technical Assistance call Yale at 1-800-810-WIRE (9473)NOTE TO INSTALLERFAILURE TO FOLLOW THESE INSTRUCTIONSCOULD RESULT IN DAMAGE TO THE PRODUCTAND VOID THE FACTORY WARRANTYAn ASSA ABLOY Group brandP/N AYRD210-INST-FUL Rev BThis document is available on our website in printed Spanish and French. Go to www.yalerealliving.com.  Click “Product Information  & Documentation” and then “Installation Instructions”.Este documento está disponible en español en nuestra página de internet. Vaya a www.yalerealliving.com.  Presione “Información del Producto y Documentación” y luego “Instrucciones de Instalación”.Ce document est disponible sur notre site Web dans le français imprimé. Allez à www.yalerealliving.com. Cliquez sur le “ ; Information sur le produit et Documentation” et puis “Installation Instructions”.
2An ASSA ABLOY Group brandP/N AYRD210-INST-FUL Rev BWarnings ..................................................................................................................... 2-4Reset Lock to Factory Default ..................................................................................3Introduction .....................................................................................................................4InstallationComponents and Tools .............................................................................................5Prepare Lock for Installation .....................................................................................6Install Lock ............................................................................................................ 7-8ProgrammingProgramming Features-Menus-Keys-Definitions ............................................... 9-10Lock Operation ................................................................................................. 11-12Miscellaneous InformationHardware Troubleshooting ......................................................................................13 Programming Troubleshooting ...............................................................................14Installing the Network Module ................................................................................15Replace/Install Cylinder ..........................................................................................16Sample Pin Code Management Sheets ........................................................... 17-18TABLE OF CONTENTSWARNINGSIMPORTANT: The accuracy of the door preparation is critical for the proper functioning and security of this product. Misalignment can cause performance degradation and a lessening of security.Finish Care: This lockset is designed to provide the highest standard of product quality and performance. Care should be taken to ensure a long-lasting finish. When cleaning is required use a soft, damp cloth. Using lacquer thinner, caustic soaps, abrasive cleaners or polishes could damage the coating and result in tarnishing.FCC: FCC ID: U4A-YRHCPZW0 (Z-Wave); U4A-YRHCPZB0 (Zigbee)Model(s): YRD210-ZW, YRD210-ZBThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful Interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:•  Reorient or relocate the receiving antenna.•  Increase the separation between the equipment and receiver.•  Connect the equipment into an outlet on a circuit different from that to which the         receiver is connected.•  Consult the dealer or an experienced radio/TV technician for help.Warning: Changes or modifications to this device not expressly approved by Yale Security, Inc. could void the user's authority to operate the equipment.
3An ASSA ABLOY Group brandP/N AYRD210-INST-FUL Rev BIMPORTANT: Do not install batteries until the lock is completely installed on door.For your convenience, the Yale Real Living lock will automatically determine whether it will function as a right or left-handed lock. (The "hand" or "handing" of the lock, is determined by the side of the entry door that the hinges are on when standing outside the door)When the batteries are properly inserted for the first time, the lock will attempt to determine its handing - whether the lock is installed on the door or not. If the lock is not completely installed on the door, it could hand itself incorrectly. Should this occur, the lock must be installed on the door and then reset to its factory defaults, allowing the lock to "hand" itself correctly.To reset the lock to factory default, see the following:The following procedure clears the automatic handing of the lock and returns the lock to programming default - deleting all user codes and setting the Master PIN code* back to the                     default ("12345678").  1. Remove the batteries and then remove the inside escutcheon           to access the reset button.2. The reset button (see image at right) is located above the            PCB cable connector. 3. Hold down the reset button for a minimum of 3 seconds and          then reinstall the batteries; once the batteries are properly              installed, release the reset button. 4. Reassemble the lock by reversing the same steps on page 6.     All features should now be returned to factory default.     Reset Lock to Factory DefaultCableReset ButtonInside Escutcheon*The default Master PIN code must be changed prior to programming of the lock.To Ensure Proper Lock Handing and for an explanation of how to determine your lock handing, please read this important note. NOTE: The bolt must be in a retracted (unlocked) position when                           installing the lockset and before batteries are installed.
4An ASSA ABLOY Group brandP/N AYRD210-INST-FUL Rev BINTRODUCTIONThe Yale Real Living™ Stand-alone Push Button Deadbolt Lock combines a robust lockset with a contemporary electronic aesthetic.Users benefit from a push button keypad that makes day-to-day access effortless for simple updates to user information in the event of staffing changes or security breaches. Yale Real Living™ is engi-neered for quick and easy installation and fits in place of a standard deadbolt lock door prep (ANSI/BHMA A156.115).If this is an RF-enabled network lock, it needs to be located within 50 - 100 feet of another network controller. That distance is influenced by objects between the lock and the controller and may be expanded depending on proximity to other RF network devices. Also, if the lock is connected to a network controller, it is recommended that it is programmed through the centralized user interface (PC or hand-held device) to ensure communication between the lock and the controller unit. Industry Canada:Canadian ID: 6982A-YRHCPZW0 (Z-Wave); 6982A-YRHCPZB0 (Zigbee)Model(s): YRD210-ZW, YRD210-ZBThis Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.For the U4A-YRHCPZB0 and 6982A-YRHCPZB0, the following statement applies:“This equipment complies with FCC/IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.”Section 7.1.2 of RSS-GEN Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.En vertu des règlements d'Industrie Canada, cet émetteur radio ne peut fonctionner avec une antenne d'un type et un maximum (ou moins) approuvés pour gagner de l'émetteur par Industrie Canada. Pour réduire le risque d'interférence aux autres utilisateurs, le type d'antenne et son gain doivent être choisies de façon que la puissance isotrope rayonnée équivalente (PIRE) ne dépasse pas ce qui est nécessaire pour une communication réussie.Section 7.1.3 of RSS-GEN This Device complies with Industry Canada License-exempt RSS standard(s). Operation is subject to the following two conditions: 1) this device may not cause interference, and 2) this device must accept any interference, including interference that may cause undesired operation of the device.Cet appareil est conforme avec Industrie Canada RSS standard exemptes de licence(s). Son fonctionnement est soumis aux deux conditions suivantes: 1) ce dispositif ne peut causer des interférences, et 2) cet appareil doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement du dispositif.
5An ASSA ABLOY Group brandP/N AYRD210-INST-FUL Rev BLock Installation #2 Phillips screwdriverDoor Prep 2-1/8" (54mm) hole saw 1" (26mm) boring bit 7/64" (2.5mm) drill bit  Chisel & hammer   Parts Illustrations    Tools NeededQuick Start GuideInstallation InstructionsDoor MarkerOutside EscutcheonBoltStrike PlateScrew PackKeys   Included in the box. . .COMPONENTS AND TOOLSInside EscutcheonInside Mounting PlateBattery Cover4 AA Alkaline BatteriesINSTALLATIONOutsideEscutcheonInside Escutcheon4 AA Alkaline Batteries(2) Through bolts KeysBattery CoverBoltStrike PlateInside Mounting PlateNetwork Module (Optional)(3) Inside Escutcheon Mounting screws(4) Bolt & Strike Plate Mounting Screws
6An ASSA ABLOY Group brandP/N AYRD210-INST-FUL Rev BPREPARE LOCK FOR INSTALLATION   Unpack the LockThe lock is packed representative of how it will install on    the door.Before installing the lock on the door:A.  Inside escutcheon       1.  Loosen the screw (Phillips #2) holding the battery             cover. (The screw remains attached to battery                   cover)       2.  Slide the battery cover up and out (note the two tabs              at bottom of battery cover).      3.  Remove the inside mounting plate (with gasket) from             the back (door side) of the inside escutcheon.Battery CoverInside EscutcheonC.  The outside escutcheon (with gasket) remains assembled.Inside Escutcheon & Mounting Plate (with gasket)Outside Escutcheon123a. Ensure that gasket on Inside Mounting Plate is properly fitted. Note the positioning of the gasket's five rubber nubs (Figure 3A) .  Figure  3AB. BoltNote: Bolt ships with backset in 2-3/8" posi-tion. If required, press small black button on underside of bolt and pull to extend to 2-3/4" backset position. Figure  3BDetail 3B1
7An ASSA ABLOY Group brandP/N AYRD210-INST-FUL Rev B1.  Install bolt in door. NOTE: The bolt must be in a retracted (unlocked) position    when installing the lockset.Attach with (2) M4 x 25.4mm [8-32 x 1"] screws supplied. 2.  Install strike on the door frame, making sure to allow       for the bolt to be centered in the strike.3.  Install outside escutcheon.     As you position the outside escutcheon, route the        cable through 2-1/8" diameter hole (Figure 3A).INSTALL LOCKFigure 4AFigure 3BFigure 3A4.  Holding the outside escutcheon flush to the door,       position the inside mounting plate by first routing       the cable and connector through the mounting         plate's 1/2" hole (Fig. 4A) and then inserting the              mounting plate “tongue“ into the bottom slot of the       outside escutcheon (Fig. 4B).  (2) M4 x 25.4mm[8-32 x 1"] Flat HeadCombination Screws(2) M4 x 25.4mm[8-32 x 1"] Flat HeadCombination Screws12Figure 4B“Tongue” NOTE: Cable goes under bolt (see Fig. 3B).
8An ASSA ABLOY Group brandP/N AYRD210-INST-FUL Rev B5.  Secure both assemblies using (2) M6 x 59.5mm            pan head machine screws, making sure that                   outside escutcheon is vertically aligned.     Hand-tighten until snug. Do not over-tighten.  7.  Install inside escutcheon on inside mounting                  plate. Note the horizontal orientation of the tail-          piece (Fig. 7A) as you insert the inside escutcheon        (thumb turn should be vertical).  8.  Install and secure using (3) M4 x 8mm [8-32 x 5/16"]         pan head screws through the inside escutcheon into         the mounting plate.6.  Attach cable assembly to the inside escutcheon       PC board by lining up notches on top of cable             connector to slots on PCB connector (Fig. 6B).Note that connector should be pressed in firmly us-ing thumbs until completely seated (proper position indicated by arrows on PCB as in Fig. 6A & 6B ) . Figure 6BFigure 7AFigure 6A CAUTION:  Use care when assembling to ensure that   the cable lies against the back recessed  area of the inside escutcheon (Fig. 6A).  Position and bend cable, using the harness    clip as shown in Fig. 6A to prevent binding    when installing the escutcheon over the   mounting plate.  Route cable as indicated - do not cover holeIMPORTANT: Before installing the batteries, test           the mechanical operation of the lock by using        both thumb turn and the key. The movement of the      bolt should be smooth and unobstructed. If        operation is not smooth, review the previous steps     to ensure proper installation.9. Insert four (4) AA alkaline batteries. The lock responds      with a series of beeps, a red/blue flash and a quick flash      of all keypad LEDs. When activating the lock for the             first time, the lock will adjust for proper handing.   Note: Refer to programming instructions prior to completion of           step 10.10. Install battery cover and tighten Phillips head screw. NOTE: The bolt must be in a retracted (unlocked) position prior to installing the batteries.
9An ASSA ABLOY Group brandP/N AYRD210-INST-FUL Rev BPROGRAMMING FEATURES - MENUS - KEYS - DEFINITIONSPhillips ScrewNetwork Module SlotAlkaline Batteries4 AA TypeThumb TurnStatus IndicatorBattery Cover   Outside    InsideStatus IndicatorNumbersPrivacy Mode Button    Menu and Icons Used in This GuideCylinderClick the indicated number.     Enter Master PIN code (4-8 digits in length).(Factory default: 12345678)Press the Star key on the keypad to Enter or Accept entry.     Enter User PIN. Can be 4-8 digits in length.Press the Pound key on the keypad to enter Menu mode.User Number (1 - 25);  RF Controlled (1 - 250).~MU   Low Battery Warning1   Lock-out Mode2     Return to previous step3    Status IndicatorsRED RED & BLUEBLUEPROGRAMMINGProgramming Features-Menus-Keys-Definitions ............................................... 8-10Operation .......................................................................................................... 11-13
10An ASSA ABLOY Group brandP/N AYRD210-INST-FUL Rev BLockout Mode: This feature is enabled by the Master code. When enabled, it restricts all user PIN code access. When attempting to enter a code while the unit is in Lockout, the Status Indicator flashes RED and BLUE; the keypad flashes as well.Low Battery: When battery power is low, the Status Indicator flashes RED. If battery power is completely lost, use the key override. Master PIN Code: The Master code is used for programming and for feature settings. NOTE: The default Master Pin Code must be changed prior to programming the lock. The Master code will also operate the lock.Privacy Mode: This button located under the thumb turn on the inside escutcheon, ac-tivates and deactivates the keypad and is indicated by a BLUE flash every ten (10) sec-onds. It is also overridden by mechanically operating the thumb turn or key.Auto Re-lock Time: After successful code entry and the unit unlocks, it will automatically re-lock after a default of thirty (30) seconds. Re-lock time is adjustable from five (5) to thirty (30) seconds.    One Touch Re-Lock: When the bolt is retracted, activating the keypad will extend the bolt       (during Auto Re-Lock duration or when Auto Re-Lock is disabled). Shutdown Time: The unit will shutdown for a default of sixty (60) seconds and not allow operation after the wrong code entry limit has been met. When the unit is in Shutdown, the Status Indicator flashes RED and BLUE; the keypad flashes as well.Silent Mode: Choosing Silent (3) in Audio mode shuts off the code confirmation tone playback for use in quiet areas. Audio mode is enabled or disabled through feature pro-gramming by the Master code.Status LED: Located on inside escutcheon. User PIN Code: The User code operates the lock. Maximum number of user codes is 250 with Network Module; without Network Module, maximum is 25 user codes.Wrong Code Entry Limit: After a specified number of unsuccessful attempts at entering a valid PIN code the unit will shut down and not allow operation. Wrong code entry limit is adjustable from three (3) to ten (10) times through feature settings (up to 5 times with no RF network enabled - default is 5; 10 with RF network enabled).     DefinitionsSettings Factory DefaultsMaster Code 12345678Auto Re-lock EnabledAudio EnabledRe-lock Time *30 SecondsWrong Code Entry Limit *5 TimesShutdown Time *60 Seconds    Factory Defaults*Adjustable with Network Module
11An ASSA ABLOY Group brandP/N AYRD210-INST-FUL Rev B    Lock Operation1Enter current Master PIN code,  followed by the   key.   1Enter '1' to change Master PIN code, followed by the   key.    2Enter the new Master PIN code (4~8 digits), followed by the  key.     31.  Enter the 8-digit default Master PIN code (12345678) followed by the   key. 2.  Enter “1” followed by the   key. 3.  Enter new 4-8 digit Master PIN code followed by the   key.    Change Default Master Code Before Programming*User Codes can only be programmed through the Master Code.1. Enter the 4-8 digit Master PIN code followed by the   key. 2. Enter “2“ followed by the   key. 3. Enter the User number to be registered (1-25) followed by the   key. 4. Enter a 4-8 digit PIN code for the User number followed by the   key.    Set Up User CodesNote: When registering User codes, the code must be entered with in 20 seconds. If time expires, no codes are registered and the process must be re-started.    PIN code structureMaximum number of user codes is 250 with Network Module; without Network Module, maximum is 25 user codes. Lockout is a Menu feature that restricts Pin code access (except Master). Privacy mode is set by pressing and holding the button (found below thumb turn) for a duration of four beeps. This deactivates the keypad, and because it is set from the inside, provides a secure lock for the convenience of the occupant(s).      Privacy Mode vs. Lockout Mode  *Default Master PIN Code must be changed prior to programming the lock.
12An ASSA ABLOY Group brandP/N AYRD210-INST-FUL Rev B     Feature Programming Through Menu Mode Using Master Code*  1. Enter the 4-8 digit Master PIN code followed by the   key. 2. Enter digit corresponding to the function to be performed followed by the   key. Note: If the lock is connected to a network controller, it is recommended that it is programmed through the centralized user interface (PC or hand-held device) to en-sure communication between the lock and the controller unit. Master PIN SettingMMUser PIN DeletionAudio Mode  All Code Lock-out    *Network Module SettingEnableEnableRegister  Disable   DeleteDisableUser Number (UN) 1~25: without network module 1~250: with network module 1 2  User PIN RegistrationCompleteUCompleteAuto Re-lock7Enable  Disable   *This function appears        only with network module   installed   1  Enter PIN code.    2Complete the code entry  by pressing the   key.Unlock.   3    Open Door with PIN Code   For quiet areas, select Disable (3) in Audio Mode.CAUTION: When joining a network your controller may or may not be aware of any previously saved user codes stored in the lock. It is recommended that all user codes be deleted from the lock prior to joining a network.
13An ASSA ABLOY Group brandP/N AYRD210-INST-FUL Rev BCycle the lock in both the locked and the unlocked positions. If problems are found: TROUBLESHOOTING    Hardware TroubleshootingMISCELLANEOUSHardware Troubleshooting ......................................................................................13 Programming Troubleshooting ...............................................................................14Installing the Network Module ................................................................................15How to Replace/Install Cylinder .............................................................................16Sample Pin Code Management Sheets ........................................................... 17-18Yale Real Living™ locks are automatically handed. On startup, hold down the reset button and wait while the lock tests bolt operation. The default Master Pin Code must be changed before any other programming.Symptom Suggested ActionDoor is binding a. Check that door and frame are properly aligned and door is free swinging.b. Check hinges: They should not be loose or have excessive wear on knuckles. Bolt will not deadlock a. Check for sufficient clearance of the bolt within the strike-side jamb. Correct this by increasing     the depth of the pocket for the bolt.b. Check for misalignment of bolt and/or strike which may be preventing bolt from properly      entering the strike. With the door open, extend and retract the bolt; if it is smooth, check the     strike alignment.Bolt does not extend or retract smoothly    a. Bolt and strike are misaligned, see above.b. Check the backset of door relative to adjustments already made to bolt.c. Verify proper door preparation and re-bore holes that are too small or misaligned.d. Verify keypad cable/connector is routed under the bolt (see Fig. A).e. Verify bolt is installed correct side up (Fig. A).                       .Figure A
14An ASSA ABLOY Group brandP/N AYRD210-INST-FUL Rev B    Programming Troubleshooting* When batteries are replaced, Network Module locks have a real time clock that will be set through the User Interface (UI); it is recommended to verify correct date and time particularly those locks operating under Daylight Saving Time (DST).Symptom Suggested ActionLock does not respond – door is open and accessible.•  Press each keypad button to see if they respond when pressed.•  Check batteries are installed and oriented correctly (polarity) in the battery case.•  Check batteries are in good condition; replace batteries* if discharged.•  Check to see if cable is fully connected and not pinched.Lock does not respond – door is locked and inaccessible. •  Lock may be in Privacy mode (set from inside room). Mechanical key will grant access.•  Batteries may be completely discharged.•  Use mechanical key to gain entry and replace batteries*.Unit chimes to indicate code accep-tance, but the door will not open.•  Check to see if there is another locking device on the door.•  Check the door gaps for any foreign objects between door and frame.•  Check that the cable is firmly connected to the PC board.Unit operates to allow access, but will not automatically re-lock. •  Check to see if Auto Re-lock Mode is enabled. •  Disable Auto Re-lock Mode to lock the door (automatically).•  If low battery indicator is lit (see below), change batteries*.PIN codes will not register. •  PIN codes must consist of 4 to 8 digits to register.•  The same PIN code cannot be used for multiple users. •  Registration/management of PIN codes is set by the authority of the Master Code.•  Contact the Master user•  User codes must be entered within 20 seconds or the process will have to be restarted.•  The star  (*) or pound   (#) cannot be used as part of the PIN code.Upon entering a PIN code and press-ing the star (*) key, the lock gives a series of beeps, flashes red and blue LEDs seven times, and does not unlock.  •  Lockout Mode is enabled.•  Only the Master can enable/disable Lockout Mode.•  Contact the Master user.Upon entering a PIN code and press-ing the (*) key, there are different tones.•  Check to see if the lock is set to Lockout Mode.•  Setting/managing Lockout Mode is done through Master Code only. Contact the Master user.The unit operates, but it makes  no sound.•  Enable Audio Mode.The unit displays intermittent RED flashes.•  This is the Low Battery indicator alerting that it is time to replace the batteries. Replace all four (4) batteries* with new AA Alkaline batteries.Upon entering a PIN code and press-ing the star (*) key, the unit responds  with a series of beeps and the keypad flashes three times.•  The digits entered were incorrect or incomplete. Re-enter the correct code followed by the star   key.** Network Module locks only
15An ASSA ABLOY Group brandP/N AYRD210-INST-FUL Rev BIMPORTANT: The batteries must be removed prior to removing and/or inserting the network module:•  Remove batteries•  Remove and/or insert network module•  Reinstall batteries   Installing the Network ModuleUse feature programming step 7 (page 13) for enrollment of the Network Module.
16An ASSA ABLOY Group brandP/N AYRD210-INST-FUL Rev B1.   Remove cylinder:A.  Remove outside escutcheon from door. B.  Remove rubber gasket.C.  Remove two screws holding plastic guide                    in place. D.  Remove plastic guide. E.  Remove screw with washer holding cylinder in       place (visible after plastic guide is removed). F.  Remove cylinder by pulling towards the       door side of escutcheon. Before installing cylinder, please be sure you have correct length tailpiece.2.   Install new cylinder:      A. Reverse previous steps for removing cylinder.   How to Replace or Install CylinderABDCFE1-3/8"* to 2" thick doors, L = 3-1/2" (88.8mm) 2" to 2-1/4" thick doors, L = 3-3/4" (95.3mm)*Requires addition of Thin Door Kit. L  Cylinder tailpiece information:T = .098" (2.5mm)W = .2" (5.2mm)wTTailpiece
17An ASSA ABLOY Group brandP/N AYRD210-INST-FUL Rev BPIN CODE MANAGEMENT SAMPLE SHEETSPIN Code Management  (No Network Module - Up to 25 Users)Location:                                                        Door Number:  User User Name User # PIN CodeUser Type User Name User  # PIN CodeMaster User 13User 1  User 14User 2 User 15User 3 User 16User 4 User 17User 5 User 18User 6 User 19User 7 User 20User 8 User 21User 9 User 22User 10 User 23User 11 User 24User 12 User 25
18An ASSA ABLOY Group brandP/N AYRD210-INST-FUL Rev BPIN Code Management (With Network Module - Up to 250 Users) - Duplicate Sheet to record entriesUser Type User Name User  # PIN Code User User Name User # PIN CodeMaster User ___ User ___ User ___ User ___  User ___  User ___  User ___ User ___   User ___  User ___  User ___ User ___  User ___ User ___  User ___ User ___   User ___  User ___  User ___ User ___  User ___ User ___  User ___ User ___   User ___  User ___  User ___ User ___  User ___ User ___  User ___ User ___   User ___  User ___  User ___ User ___  User ___ User ___  User ___ User ___   User ___  User ___  User ___ User ___  User ___ User ___  User ___ User ___   User ___  User ___  User ___ User ___  User ___ User ___  User ___ User ___   User ___  User ___  User ___ User ___  User ___ User ___  User ___ User ___   User ___  User ___  User ___ User ___  User ___ User ___   User ___  User ___  User ___ User ___  User ___ User ___  User ___ User ___   User ___  User ___  User ___ User ___  User ___ User ___   User ___  User ___  User ___
ONLINE LITERATURE AND TEMPLATESFor the latest information on Yale products visit our website at www.yalelocks.com. Click on the “Literature” button to find the most up-to-date catalogs, parts manuals, templates, specifica-tions and installation instructions.An ASSA ABLOY Group brandP/N AYRD210-INST-FUL Rev BYale Locks & Hardware100 Yale Avenue, Lenoir City, TN 37771 • Product Support Tel 800.810.WIRE (9473) • www.yalelocks.comYale Locks & Hardware is a division of Yale Security Inc., an ASSA ABLOY Group company. Yale® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Yale Real Living™ is a trademark of Yale Security Inc., an ASSA ABLOY Group company. Copyright © 2011, Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without express written permission of Yale Security Inc., an ASSA ABLOY Group company is prohibited.YALE, with its unique global reach and range of products, is the world’s favorite lock — the preferred solution for securing your home, family and personal belongings.ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience.

Navigation menu