    5015 B.U. Bowman Drive  Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598   Certification Exhibit     FCC ID:  U4A-SCYICLS0 IC: 6982A-SCYICLS0  FCC Rule Part: 15.225 IC Radio Standards Specification: RSS-210  ACS Report Number:  11-0125.W06.11.A   Manufacturer: Assa Abloy, Inc. Models: TCWI1-M812/M813, TCIP1-M812/M813     Manual
Installation InstructionsFor ML20800 TCWI1/TCIP1 SeriesMortise LocksetImportant: The accuracy of the door preparation is critical for proper functioning and security of this lock.                    Misalignment can cause premature wear and a lessening of security. Please read these instructions carefully to prevent missing important steps.Please Note: Improper installation may result in damage to the lock and void the factory warranty.            FM 335(Rev. 0/2011)For installation assistance contact Corbin Russwin Inc., at 1-800-810-WIRE (9473) CAUTIONDOOR MUST REMAIN OPENDURING INSTALLATION.USE DOOR STOP.1 2 34758069#*TESTFOR PROPEROPERATIONBEFORECLOSINGDOORAccess 800TM
 1    ML20800 TCWI1/ TCIP1 Series Mortise Lock                        1) Warning……………………………………………………………….   1 2)  General Description………………………………………………….     2 3)  Specifications/ Features…………………………….………………    2 4)  Product Illustration……………..…………………………………….    3 5)  Installation Instructions………………………………………………  4-10 6)  Wiring Diagrams……………………………………………………..   11-17 7)  Mechanical Operation Check ………………………………………   18 8) Electrical Operation Check………………………………………….   19     TCWI1 - WiFi NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: •  Reorient or relocate the receiving antenna. •  Increase the separation between the equipment and receiver. •  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  •  Consult the dealer or an experienced radio/TV technician for help. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.  Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.  This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.     TCIP1 - POE NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.  Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.  This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.  Copyright © 2011 Corbin Russwin, Inc. All rights reserved.  Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. Table of Contents 1) Warning Warning: Changes or modifications to this unit not expressly approved by ASSA ABLOY Inc. could void the user’s authority to operate the equipment
 2    ML20800 TCWI1/TCIP1 Series Mortise Lock            The Corbin Russwin Access 800 Series mortise locks are available in WiFi (WI1) and PoE (IP1) configurations. When coupled with third party software the WI1 and IP1 offer a complete integrated access control system. The Access 800 may be used for both indoor and outdoor applications (weather gaskets supplied).         Hardware Specifications   Latch – Stainless Steel (Easily field reversible without disassembling lock body)   Deadbolt – Stainless Steel   Door Thickness – 1-3/4” Standard; Consult factory for other door thicknesses   Case – 12 gauge heavy duty wrought steel   Outside lever controlled by 125kHz Prox reader, 13.56MHz iCLASS reader, keypad, and/or mechanical key   Inside lever retracts latch   BHMA Grade 1; UL Fire Listed   Outside lever for iCLASS controlled by HID iCLASS credential or other 13.56 MHz credential (such as CSN, Chip Serial Number, read only supported, including MiFare, DesFire, and FeliCa.   Electrical Specifications:   2400 users per lock; 10,000 event audit trail   Multiple time zone and holiday access scheduling   First-In unlock configuration, either by time or by valid time or by user (selectable)     TCWI1 – WiFi  WiFi 802.11b/g   DC9V, 1.5A (6 AA Alkaline Batteries or Remote Electrical Power)   TCIP1 – PoE  Class 2 Device, as defined by IEEE 802.3af, requires up to 7 watts over structured cabling       Copyright © 2011 Corbin Russwin, Inc. All rights reserved.  Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. 2) General Description3) Specifications/ Features
33) ML20800 Series Product Illustration
Verify Hand and Bevel of door. Illustrations shown are as viewed from the outside or secure side of opening.14) Installation Instructions324Prep door according to supplied Corbin Russwin Inc. door marker.FORUSEON FIREDOORNOTLeft HandHinges Left.Open Inward."LH"Left HandReverse BevelHinges Left.Open Outward"LHR"Right HandHinges Right.Open Inward."RH"Right HandReverse BevelHinges Right.Open Outward"RHR"7/8"1-1/21/8" Dia. holes(2) requiredFire Stop Plate required for fire rated doorsSlotAttach Fire Stop PlateUsing self tapping screws#8-32x1/2 long for wood &metal doors.C of 1-1/2 DiaLOutsideof DoorHole for ribbon cableNon Fire Rated Exterior Doorsinstall weather conduit.(Hollow Doors Only)Outsideof DoorNon Fire Rated DoorHole for ribbon cableInstall conduit half with recessedpanel "Not For Use On Fire Door"visible from outside of door.The Optional Conduit is availablefor Non Fire rated doors to provideweather protection for exterior doorapplications. It is included in the M99Weatherseal Gasketing Kit whenordered with the device. If orderedseparately, order part number794F929.
Lock Assembly InstructionsAlign bevel accordingly. Engage 7/64 Allen wrench on to cap screw required for step 2 page 6. Feed connector and wires through 1 (25) dia. wire access hole. Insert lockbodyinto mortised cutout in door and hold loosely in place with (2) #12x1" lockbody screws. 3Installation Instructions5(2) #12x1"combination screwsLockbody7/64 Allen WrenchInsideof Door   Feed connectors & wires through wire access hole
46SpindlesKeypad ribbon cableOutsideof DoorInstallation of Outside Escutcheon2A. For fire rated doors feed ribbon cable connector and ground wire from outside escutcheon        through the fire stop plate.2B. For non-fire rated doors, feed ribbon cable connector and ground wire from outside escutcheon         through weather seal gasket (if used), then conduit sleeve in door (not shown). 3. With outside lever horizontal, insert mounting posts into the door. Make certain      the lever spindle is properly engaged in lock. (see diagram and Note A. below)     Screw cylinder into mortise lockbody make certain the cylinder orientation is in the correct        position (see diagram below) . Using the 7/64 Allen wrench provided, hand tighten (5-10 in. lbs.)           the cap screw to prevent unscrewing of the cylinder. Turn the key to make certain that the       locking mechanism (latch, deadbolt, key) functions correctly. Tighten (2) #12 x 1" lockbody       screws. Remove Allen wrench.Installation InstructionsGroundwireGasket (optional)CAUTIONDOOR MUST REMAIN OPENDURING INSTALLATION.USE DOOR STOP.NOTE: Key and cylinder must be rotated as shownCorrect IncorrectUse Correct Spindle OrientationSTANDARD MUSÉOGASKET APPLICATION:Peel off the adhesive protective paper from gasket. Feed Trim assembly motor harness through gasket opening as shown and firmly press gasket to escutcheon, aligning edge of gasket with the edge of the escutcheon.  1. For exterior applications, an optional M99 Weatherseal Gasketing Kit can be ordered when a      device is ordered. this kit includes gaskets and a conduit. When ordering the kit separately,      order part number 794F929. The gaskets may be used as a seal between the escutcheon      and the door surfaces.NOTE A.For MUSÉO Lever collections ONLY.Rotate adapter bushing as neededto insure horizontal lever position and maximum thread engaging lever - adapter bushing.LeverLever
57Motor connectorGround TerminalRed & Black wiresKeypad ribbon cableLocate (3) oval head screwsand insert through theEscutcheon and threadinto the outside Escutcheon.GroundWireKeypad harness(ribbon cable)Remote PowerConnector(M35 Remote PowerWiring Harness alsoavailable as partNo. 793F069)        TuInsideof doorTurnpieceInstallation of Inside EscutcheonNOTE: Connectors go on only one way.  Do not offset connector and be sure they are completely seated.1. Remove black battery cover from the eschutcheon with High Security T20 Trox bit provided. 2. Connect Ground wire to Ground terminal, Keypad ribbon cable connector to controller, lockbodyharness to motor connector, DPS conector on lockbody harness to remote power and DPS harness, and     connect remote power if applicable. 3. Align turnpiece to the vertical position.4. Push excess keypad ribbon cable into the ribbon cable hole.Installation InstructionsControllerTurnpiece male switch 1Male turnpieceswitch connectorCAUTIONDOOR MUST REMAIN OPENDURING INSTALLATION.USE DOOR STOP.Lockbody HarnessLockbodyHarnessGasketGASKET APPLICATION:Peel off the adhesive protective paper from gasket. Feed Trim assembly motor harness through gasket opening as shown and firmly press gasket to escutcheon, aligning edge of gasket with the edge of the escutcheon.Lockbody HarnessMotor connectorKeypad harness (ribbon cable)Ground TerminalRemote powerDPSRemote power and DPS
58Installation InstructionsInstallation of Inside Escutcheon (continued)CAUTION: Do not allow lockbody harness wires to enter cylinder hole in lockbody. Wiredamage and/or malfunction of the lock may occur. 1. Turn inside lever to the horizontal position and rotate the turnpiece to the vertical position. Slide      onto spindle halfway. With inside escutcheon resting on spindle, be certain that all keypad ribbon      cable will remain inside ribbon cable hole,  and that ground wire will not get pinched once     escutcheon is mounted.  Escutcheon will not fit flush on door otherwise.  2. Insert 3 #10-24 screws through inside escutcheon and thread loosely into outside escutcheon.  Check        operation of both inside and outside levers and make sure the turnpiece and key still operate the       latch and deadbolt correctly. If lock function is satisfactory, fully tighten the bottom two screws.         Check operation of both levers again. If levers move freely, tighten top screw.  If levers do not move     freely, loosen bottom screws and realign the escutcheons until proper operation is obtained.   Insideof doorLockbody harness - Feed excesswire back into the mortise of thedoor between the door cavity andlockbody. Do not feed excesswires into the cylinder hole ofthe lock.
6Installation Instructions9   Installation of Armored Front Plate1.Install armored front plate using two #8-32 x 1/4"screws provided.Lockbody screwsFront PlatescrewsArmored Front Plate
 7Installation InstructionsBattery Polarity10Tabs Retaining SlotsSecurity ScrewBattery KeeperBottom TabsTop Tab   Battery Installation1. Remove battery keeper by lifting top tab and pulling away from the unit.2. Install (6) AA Batteries into controller compartment being careful to align +/- polarity      properly.3. Install Battery Keeper by first inserting bottom tabs in bottom slots of controller. Lift the    top tab over batteries and snap into position.4. Attach battery cover to inside controller escutcheon making sure to line up tabs with     retaining slots in battery cover. Secure with security screw using security T20 bit.T20 bitTESTFOR PROPEROPERATIONBEFORECLOSINGDOORCAUTIONDOOR MUST REMAIN OPENDURING INSTALLATION.USE DOOR STOP.
5) Operational Check 811       Lock Operational Check For devices with cylinders:   1. Insert key into cylinder and rotate. (There should be no friction against lock case, wire       harness or any other obstructions)2. The key will retract the latch, key should rotate freely. If the deadbolt is thrown, the key will     first retract the deadbolt and then the latch. Inside lever retracts latch and deadbolt, if       provided.3.8VH3UR[LPLW\&DUGRU3LQFRGHVHWXSZLWK/RFN&RQILJXUDWLRQ7RRO7KLVVKRXOGXQORFNRXWVLGHOHYHUDQGDOORZODWFKWREHUHWUDFWHG3OHDVHVHH1HWZRUN/RFN&RQILJXUDWLRQ     7RRO8VHU0DQXDO:)01IRUPRUHLQIRUPDWLRQCAUTIONDOOR MUST REMAIN OPENDURING INSTALLATION.USE DOOR STOP.TESTFOR PROPEROPERATIONBEFORECLOSINGDOORCorbin Russwin, Inc.                 Technical Product Support:         225 Episcopal Road                 Corbin Russwin, Inc.Berlin, CT 06037-4004                 Phone 800-810-WIRE (9473)        www.corbinrusswin.comcopyright 2007Canada: Assa Abloy DSS Canada160 Four Valley DriveVaughun, ONT L4K 4TGwww.yalecorbin.on.ca
6)  ML20800 Hard Wiring Instructions121. Caution:  disconnect all input power before beginning installation to prevent electrical shock and equipment damage.2. Installer must be a trained, experienced service person.3. All wiring must comply with applicable local electrical codes, ordinances and regulations.6.1)      Important1. With new applications, an ElectroLynx™ door harness with 8 and 4 pin connectors will be pre-installed inside door by ASSA ABLOY door manufacturer when specified during ordering process.2. Wiring to pigtail harness is per facility wiring requirement. ElectroLynx™ connector terminations and wire colors all match.3. If door does not have an ElectroLynx™ type door harness, cut connectors off product and hard wire, or consult factory for appropriate mating harness. 6.2)      Installation NotesThe system is designed to be installation friendly with pluggable connectors from theelectric hinge through the door to the rail. The only wiring required is to the loose wireson the pigtail harness assembly on the frame side of the electric hinge.IMPORTANT:The plug and receptacle connectors are designed to mate and lock together as shownin the figure. Plug the connectors into each other with the locking mechanism alignedas indicated.Do NOT Force connectors on any other way.6.3)      ElectroLynx™ Connector System Notes:As part of their promise to provideinnovative, fast and effective, and highersecurity solutions to their customers,ASSA ABLOY Group companies offerElectroLynx™, a universal quick-connectsystem that simplifies the electrification of the door opening.ElectroLynx™ is a registered trademark of ASSA ABLOY North America, Inc. ReceptacleLocking MechanismPlugHardwiring Made EasyELECTROTM
6)  ML20800 Hard Wiring Instructions13ELECTRO6.4)     Hard Powered Connections END OF INSTALLATION INSTRUCTIONS