   ONE-TOUCH WIRELESS HEALTH TRACKER  BODY LIFE TRACKER User Manual Model: VA06        Document No  : AMI-PRD-UM-B-VA06 Version   :  1.1 Date    :  25.09.2015
B.O.L.T User Manual    Model No: VA06    2 © Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.  Legal Disclaimer This  publication/content  contains  proprietary  information  which  is  protected  by  copyright.    No part of this publication may be reproduced, transcribed, stored in a retrieval system, translated into any language or computer language, or transmitted in any form whatsoever without the prior written  consent  of  the  publisher.  American  Megatrends  India  Private  Ltd.  retains  the  right  to update, change or modify this publication at any time, without notice. For Additional Information Call American Megatrends India Private Ltd at 1800-419-9868. Limitations of Liability In no event shall American Megatrends India Private Ltd be held liable for any loss, expenses, or damage  of  any  kind  whatsoever,  whether  direct,  indirect,  incidental,  or  consequential,  arising from the design or use of this product or the support materials provided with the product. Limited Warranty No warranties are made, either expressed or implied, with regard to the contents of this work, its merchantability, or fitness for a particular use. American Megatrends India Private Ltd assumes no responsibility for errors and omissions or for the uses made of the material contained herein or reader decisions based on such use. Trademark and Copyright Acknowledgments Copyright © 2015 American Megatrends India Private Ltd.  All Rights Reserved. AMERICAN MEGATRENDS INDIA PRIVATE LTD., KUMARAN NAGAR, SEMMANCHERY VILLAGE, CHENNAI (TN) 600119.  All  product  names  used  in  this  publication  are  for  identification  purposes  only  and  are trademarks of their respective companies.
B.O.L.T User Manual    Model No: VA06    3 © Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.  B.O.L.T VA06 User Manual  Model  VA06  –  NIBP  Monitor  (Systole  Diastole  Pulse  Rate),  Infrared  Ear Thermometer  (Temperature),  Pulse  Oximeter  (SpO2  &  Pulse  Rate), Gluchobin  (Blood  Glucose,  Blood  Cholesterol  &  Blood  Hemoglobin Levels)  Thank you very much for purchasing B.O.L.T the One -Touch Wireless Health Tracker. Please read this User  Manual thoroughly to  ensure safe and  correct use of  the product.  Please  keep this User Manual for future reference.        B.O.L.T  is  a  medical  gadget  with  NiBP  (Non-invasive  Blood  Pressure),  SpO2  (Pulse  Oximeter) Infrared Thermometer (IRT) and Gluchobin (Invasive) combined into a small form factor device which gets controlled from a mobile device. B.O.L.T is a cloud enabled solution. With B.O.L.T your health vitals can be stored in your personal health cloud. For B.O.L.T to be in your hands, all you need is any leading mobile device that operates with the compatible Operating System.
B.O.L.T User Manual    Model No: VA06    4 © Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.   Table of Contents  Safety Measures ....................................................................................... 5 Warning .............................................................................................. 5 Caution ............................................................................................... 5 Care and Maintenance ............................................................................. 6 Know Your Unit ........................................................................................ 6 Intended use ........................................................................................... 7 Prerequisites ........................................................................................... 7 Using B.O.L.T Application ........................................................................... 7 Blood Pressure Measurement Procedures ...................................................... 7 Blood Pressure Classification for Adults ..................................................... 9 Blood Oxygen Level Measurement Procedures ............................................... 10 Blood Oxygen Level Classification ............................................................ 11 Temperature Measurement Procedures ......................................................... 11 Temperature Classification ...................................................................... 12 Blood Glucose Level Measurement Procedures .............................................. 13 Blood Glucose Level Classification ........................................................... 15 Blood Hemoglobin Level Measurement Procedures .......................................... 16 Blood Hemoglobin Level Classification ...................................................... 18 Blood Cholesterol Level Measurement Procedures .......................................... 19 Blood Cholesterol Level Classification ....................................................... 21 Replacement of Battery Pack ...................................................................... 23 Explanation of Indicators/Symbols ............................................................... 24 Technical Specifications ........................................................................... 26 Certifications .......................................................................................... 27 FCC compliance statements ....................................................................... 28 Warranty Information ................................................................................ 29 Customer Care Support ............................................................................ 29
B.O.L.T User Manual    Model No: VA06    5 © Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.  Safety Measures Warning     If  you  encounter  any  problem  while  taking  blood  pressure  measurement,  such  as  inflation does not stop or air leakage in the cuff, remove the cuff or pull out the air tube from the base unit.   Do not wrap BP cuff over the arm where an intravenous injection or transfusion is being given to the patient.    Do  not  operate  the  gadget  in  places  where  inflammable  gas,  such  as  highly  inflammable anesthetic, may be generated or in a high-pressure oxygen room or in an oxygen tent.   Keep the gadget away from infants, small children or anyone who are incapable of using the gadget in the correct manner.   Please do not use the same cuff for patients who are highly infectious as this practice may cause cross-infection.   Make sure the ear canal is clean for before performing temperature measurement.    Use dust cover for Ear Thermometer during the temperature measurement.   Place the finger inside the SpO2 probe properly during the Blood oxygen level measurement.   Lancet needle, Glucose strips, Hemoglobin strips, and Cholesterol strips are meant for single user / Single use only.    Lancet is to be used only on the tip of finger and not anywhere else.    Do not set the pricking lancet at a higher penetration depth unless it is necessary for a thicker skin.  Caution    Do not use the gadget while moving in a vehicle as this may result in erroneous readings.   Do not use any other branded cuffs as this may result in reading errors.   Do not use unauthorized parts and accessories.   Do  not  store  or  use  this  gadget  in  locations  which  are  maintained  above  the  specified temperature and humidity ranges.   Finger nail polish or false fingernails may cause inaccurate SpO2 readings.   SpO2 measurements may be adversely affected in the presence of high ambient light.   Dispose the used lancet pin and cotton in an appropriate container.   Use only American Megatrends India Specified batteries and charging devices.
B.O.L.T User Manual    Model No: VA06    6 © Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.  Care and Maintenance    Store the gadget and the components in a clean and safe location.   Changes or modifications not approved by the manufacturer will void the user warranty.   Keep the accessories and gadget away from rain, sweat and water.   Do not disassemble, repair or modify the gadget and the components by yourself, hence this could void the user's authority to operate the device.   Clean the rubber touching the finger inside the SpO2 probe gently by a soft cloth dampened with 70% isopropyl alcohol before measurement.   Store the test strips at room temperature between 2°C to 32°C(36°F to 90°F).    Do not refrigerate or freeze the test strips.   Keep the test strips slot of the Gluchobin device free from dust.    After pulling out the test strip from its container, seal the cap of the container tightly to protect test strips.     Know Your Unit The base unit has an elegant look and feel with two LED indicators, an accessory connector and a power ON/OFF sliding switch as shown below. Accessories like cuff, IR Ear Thermometer with cover, SpO2 probe, Gluchobin and USB cable with power adapter are provided along with the base unit.  Features of the Product   Elegant design enables simple and easy use of the product.   Multiple Platform Support and same application for multiple users.   Secured Cloud application to share and manage trends with health data.   Monitor and share your health trends with doctor and loved ones.   Safe and convenient to use.
B.O.L.T User Manual    Model No: VA06    7 © Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.  Intended use B.O.L.T (VA06) It  is  used  to  measure  the  vital  signs  like  Blood  Pressure,  Body  temperature,  Blood  oxygen saturation level & Blood glucose, hemoglobin, cholesterol levels. The B.O.L.T device is controlled from a mobile device. Prerequisites Some basic requirements must be adopted as mentioned below to ensure better operation of the product.   B.O.L.T is designed to be operated with applications like Android, iOS or Windows.   The Android OS version of the using computer/mobile device should be 4.0 or higher.   The iOS version of the using computer/mobile device should be 7 or higher.   The Windows OS version of the using computer/mobile device should be 8 or higher. Using B.O.L.T Application       Downloading and Installing B.O.L.T application in your computer/mobile device 1.  Download and Install B.O.L.T application from the Play store/Application store/Windows application market. 2.  On successful installation, launch the B.O.L.T application in the mobile device. 3.  Create a User Name with your Email ID or use Facebook/Google+ Credentials for login.  4.  On successful Login, provide permission for cloud service by enabling the Save in cloud option and enter near and dear details under settings panel at left top corner of the home view. Note:  You  can  also  login  as  a  guest  user  while  internet  unavailability which  might  not  store  the  measured  vital  parameters  in  the  cloud  storage space on the measured parameters.  Blood Pressure Measurement Procedures  Mandatory instructions to be followed during blood pressure measurement   Relax yourself in a comfortable position.   Avoid eating, exercising and smoking for 30 minutes before taking a measurement.   Avoid taking measurements during stressful times.   Remove tight-fitting clothing from the right upper arm.   Sit in a chair with your feet flat on the floor and place the right arm on a table as shown below.
B.O.L.T User Manual    Model No: VA06    8 © Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.      Apply the cuff to the right upper arm so that the cuff is wrapped at the same level of your heart.    Ensure that the arrow present in the BP cuff points towards the artery along the middle finger of the right hand as shown below.    Stay calm without shaking the hand during the measurement.  Blood Pressure measurement with B.O.L.T      B.O.L.T enables connecting an air hose through which the blood pressure is monitored.   Connecting air hose with the gadget and launching B.O.L.T application  1.  Insert the BP connector plug into the BP socket firmly as shown above. 2.  Switch ON the gadget using the ON/OFF sliding switch. 3.  Enable Bluetooth and Internet Connectivity in the computer/mobile device. 4.  Launch the B.O.L.T application in the computer/mobile device. 5.  Login with the User Name and Password which is used for the registration.
B.O.L.T User Manual    Model No: VA06    9 © Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.   Measuring BP with B.O.L.T   1. On successful login of the B.O.L.T application, Select “How is my health” option to perform Master Health checkup or select “Check Vitals” option to perform individual test. 2.  Confirm the Bluetooth device to turn-on. 3.  Select the B.O.L.T device from the list of available Bluetooth devices and confirm. 4.  Provide default password (1234/0000) for pairing your B.O.L.T device with mobile device on your first time usage (only for android).  5.  Wrap the cuff around the upper arm of the right hand above the elbow. 6.  Ensure that the arrow in the BP cuff points the artery along the middle finger of the right hand as discussed earlier in the Blood Pressure measurement procedure section. 7.  Start the Blood Pressure measurement using the application screen. 8.  Ensure that the person remains stable until the application displays the results. 9.  On successful measurement, the Blood Pressure and Pulse rate are displayed and a copy of reading will be mailed to your Near & Dear mail IDs on saving the data. 10. Multiple readings  can be taken  with  atleast  1 minute  interval  by  selecting  the  auto-reading option. Note:  On  Successful  pairing  of  the  mobile device,  Bluetooth  light  stops blinking in the gadget. Ensure that the save option is enabled for storing the data in cloud.  Blood Pressure Classification for Adults  The  World  Health  Organization  (WHO)  has  created  the  following  classification  for  assessing  high blood  pressure  (Hypertension).  Please  note  that  this  table  can  give  only  a  generic  view  as  other factors  such  as  diabetes,  obesity  and  smoking,  also  need  to  be  considered  for  understanding  the different ranges. Consult with your physician for accurate assessment.  Blood Pressure Classification Systole Diastole Low <110 <75 Normal 110-120 75-80 Pre-Hypertension (mild) 120-139 80-89 Stage 1 Hypertension (high) 140-159 90-99 Stage 2 Hypertension (severe) >159 >99
B.O.L.T User Manual    Model No: VA06    10 © Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.   Blood Oxygen Level Measurement Procedures  Mandatory instructions to be followed during blood oxygen level measurement   Relax yourself in a comfortable position.   Remain stable during the measurement.   Place the finger properly inside the SpO2 probe.   Clean the surface of the fingertip before the measurement.  Blood Oxygen Level measurement with B.O.L.T    B.O.L.T enables connecting a SpO2 probe through which the blood oxygen level is measured.  Connecting SpO2 probe with the gadget  Insert the SpO2 connector into the socket firmly as shown below.   Note: Ensure to clean your hands before taking SpO2 measurement. Some SpO2 reading  fluctuation  may  be  occurred  of  below  85%  for  certain  ethnicity group. If  the  SpO2  values  are  deviated  below  70%  or  above  100%,  ensure  that  the user positions his finger properly as shown below.    Measuring Blood Oxygen Level with B.O.L.T  1.  Clean the rubber pad of the SpO2 probe touching the finger gently by a soft cloth dampened with 70% isopropyl alcohol and let air dry or use soft dry cloth to clean before measurement.
B.O.L.T User Manual    Model No: VA06    11 © Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.  2.  Clean your hands with hand wash before the measurement.  3. Select “Check Vitals” option to perform individual test. 4. Clip the SpO2 probe  in the index finger of the person to be measured in right/left hand as displayed above. 5.  Select the Blood Oxygen option from the application screen. 6.  On  successful measurement,  the  SpO2  value  and  Pulse rate  are  displayed and  a copy of reading will be mailed to your Near & Dear mail IDs on saving the data.  Blood Oxygen Level Classification Please  note  that  this  table  can  give  only  a  generic  view.  Consult  with  your  physician  for  accurate assessment.  SpO2 Classification Range Hypoxemia (low)                            < 95 % Normal 95-100 %     Temperature Measurement Procedures d Mandatory instructions to be followed during temperature measurement   Relax yourself in a comfortable position.   Use new dust cover for each measurement.   Place the Ear Thermometer firmly into the ear canal for accurate measurement.   Remain stable during the measurement.   Wait until the application displays the measured temperature. Body Temperature measurement with B.O.L.T  B.O.L.T enables connecting an IR Ear Thermometer through which the temperature is measured.  Connecting IR Ear Thermometer with the gadget  Insert the IR Ear Thermometer connector into the socket firmly as shown below.
B.O.L.T User Manual    Model No: VA06    12 © Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.   Measuring Body Temperature with B.O.L.T  1. Select “Check Vitals” option to perform individual test. 2.  Use dust cover over the tip of the Ear Thermometer. 3.  Place  the  Ear  Thermometer  inside  the  ear  horizontally  as  such  the  pointer  maintains horizontal position as displayed above. 4.  Select the Body temperature option from the application screen. 5.  On  successful  measurement,  the  temperature  value  is  displayed  and  a  copy  of  the reading will be mailed to your Near & Dear mail IDs on saving the data.  Temperature Classification  Please  note  that  this  table  can  give  only  a  generic  view.  Consult  with  your  physician  for accurate assessment.   Temperature Classification Range Hypothermia <36.3 °C (< 97.5  °F) Normal 36.4 – 37.5 °C (97.6- 99.5  °F) Hyperthermia >37.5.°C (>99.5  °F)
B.O.L.T User Manual    Model No: VA06    13 © Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.  Blood Glucose Level Measurement Procedures  Mandatory instructions to be followed during the measurement   Relax yourself in a comfortable position.  Blood Glucose level measurement with B.O.L.T  B.O.L.T  enables  connecting  a  Gluchobin  through  which  the  glucose  test  strip  are  inserted  for measurement.  Using Lancet pen and Lancet  1.  Unscrew and remove the lancet pen `s adjustable tip as shown below.    2.  Insert a lancet into the carrier as shown below.               3.  Twist off the protective cover.
B.O.L.T User Manual    Model No: VA06    14 © Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.  4.  Replace the adjustable tip tightly. Choose a desired skin penetration depth by rotating the top portion of the adjustable tip until the setting number lines up to the arrow. 5.  Settings are based on skin type: Depth 1-2 for soft or thin skin Depth 3 for average skin Depth 4-5 for thick or calloused skin 6.  Hold the tip of the lancet pen with one hand and pull the sliding barrel with the other hand. When a click is felt, the trigger rises up. Release the sliding barrel, it will move back to its original position.  Connecting Gluchobin with the gadget  7. Insert the Gluchobin connector into the socket firmly as shown below.   Gluchobin connected to B.O.L.T Device 8.  Select Gluchobin and choose the “Glucose” option from the application screen of the mobile device. 9.  Insert the blood glucose test strip into the test strip slot of the Gluchobin as shown below.            10. Click “Start” in the application screen of the mobile device. 11. Clean your finger with alcohol swap and let it dry completely.  12. Place the lancet pen on side of your fingertip.  13. Press the trigger on the lancet pen as shown above. 14. Get a drop of blood and place the blood drop on the test strip target area.
B.O.L.T User Manual    Model No: VA06    15 © Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.   15. On successful test completion, the test result will be displayed in 6 or 7 second on the application screen. 16. Wipe any excess blood on the finger with the cotton and dispose it properly. 17. Choose the options “before meal” or “just after meal” or “3 hours after meal” as per the status of the user in the application screen. 18. Pull the test strip out of the Gluchobin. 19. Unscrew the adjustable tip of the lancet pen. 20. Place the protective cover of the lancet back on the lancet as shown below.      21. Discard the used lancet in an appropriate container. 22. Screw the adjustable tip back on the lancet pen. Note: Ensure that the test strip gets enough blood. Else try to use a new test strip to do the test again.  To avoid accidental injury, always remove the used lancet immediately after each test.   Blood Glucose Level Classification  Blood Glucose Classification Before Meal 3 Hours after meal Normal 70-100 70-140 Pre-Diabetic 101-125 141-200 Diabetic 126 & above 200 & above
B.O.L.T User Manual    Model No: VA06    16 © Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.  Blood Hemoglobin Level Measurement Procedures  Mandatory instructions to be followed during the measurement   Relax yourself in a comfortable position.  Blood Hemoglobin level measurement with B.O.L.T  B.O.L.T  enables  connecting  a  Gluchobin  through  which  the  hemoglobin  test  strip  are  inserted  for measurement.  Using Lancet pen and Lancet  1.  Unscrew and remove the lancet pen `s adjustable tip as shown below.    2.  Insert a lancet into the carrier as shown below.              3.  Twist off the protective cover.   4.  Replace the adjustable tip tightly. Choose a desired skin penetration depth by rotating the top portion of the adjustable tip until the setting number lines up to the arrow. 5.  Settings are based on skin type: Depth 1-2 for soft or thin skin
B.O.L.T User Manual    Model No: VA06    17 © Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.  Depth 3 for average skin Depth 4-5 for thick or calloused skin 6.  Hold the tip of the lancet pen with one hand and pull the sliding barrel with the other hand. When a click is felt, the trigger rises up. Release the sliding barrel, it will move back to its original position.  Connecting Gluchobin with the gadget  7.  Insert the Gluchobin connector into the socket firmly as shown below.   Gluchobin connected to B.O.L.T Device  8.  Select Gluchobin and choose the “Hemoglobin” option from the application screen of the mobile device. 9.  Insert the hemoglobin test strip into the test strip slot of the Gluchobin as shown below.            10. Click “Start” in the application screen of the mobile device. 11. Clean your finger with alcohol swap and let it dry completely.  12. Place the lancet pen on side of your fingertip.  13. Press the trigger on the lancet pen as shown above. 14. Get a drop of blood and place the blood drop on the test strip target area.
B.O.L.T User Manual    Model No: VA06    18 © Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.   15. On successful test completion, the test result will be displayed in few seconds on the application screen. 16. Wipe any excess blood on the finger with the cotton and dispose it properly. 17. Pull the test strip out of the Gluchobin. 18. Unscrew the adjustable tip of the lancet pen. 19. Place the protective cover of the lancet back on the lancet as shown below.      20. Discard the used lancet in an appropriate container. 21. Screw the adjustable tip back on the lancet pen. Note: Ensure that the test strip gets enough blood. Else try to use a new test strip to do the test again.  To avoid accidental injury, always remove the used lancet immediately after each test.   Blood Hemoglobin Level Classification  Population Non –Anemic g/dl Mild g/dl Moderate g/dl Severe g/dl Children 6 - 59 months of age >11.0 10.0 – 10.9 7.0 – 9.9 < 7.0 Children 5 - 11 years of age >11.5 11.0 – 11.4 8.0 – 10.9 < 8.0 Children 12 - 14 years of age >12.0 11.0 – 11.9 8.0 – 10.9 < 8.0 Non-pregnant women >12.0 11.0 – 11.9 8.0 – 10.9 < 8.0 Pregnant women >11.0 10.0 – 10.9 7.0 – 9.9 < 7.0 Men (15 years of age and above) >13.0 11.0 – 12.9 8.0 – 10.9 < 8.0
B.O.L.T User Manual    Model No: VA06    19 © Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.  Blood Cholesterol Level Measurement Procedures  Mandatory instructions to be followed during the measurement   Relax yourself in a comfortable position.  Blood Cholesterol level measurement with B.O.L.T  B.O.L.T  enables  connecting  a  Gluchobin  through  which  the  cholesterol  test  strip  are  inserted  for measurement.  Using Lancet pen and Lancet  1.  Unscrew and remove the lancet pen `s adjustable tip as shown below.     2.  Insert a lancet into the carrier as shown below.                     3.  Twist off the protective cover.
B.O.L.T User Manual    Model No: VA06    20 © Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.   4.  Replace the adjustable tip tightly. Choose a desired skin penetration depth by rotating the top portion of the adjustable tip until the setting number lines up to the arrow. 5.  Settings are based on skin type: Depth 1-2 for soft or thin skin Depth 3 for average skin Depth 4-5 for thick or calloused skin 6.  Hold the tip of the lancet pen with one hand and pull the sliding barrel with the other hand. When a click is felt, the trigger rises up. Release the sliding barrel, it will move back to its original position.  Connecting Gluchobin with the gadget  7. Insert the Gluchobin connector into the socket firmly as shown below.   Gluchobin connected to B.O.L.T Device  8.  Select Gluchobin and choose the “Cholesterol” option from the application screen of the mobile device. 9.  Insert the cholesterol test strip into the test strip slot of the Gluchobin as shown below.            10. Click “Start” in the application screen of the mobile device. 11. Clean your finger with alcohol swap and let it dry completely.  12. Place the lancet pen on side of your fingertip.  13. Press the trigger on the lancet pen as shown above. 14. Get a drop of blood and place the blood drop on the test strip target area.
B.O.L.T User Manual    Model No: VA06    21 © Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.    15. On successful test completion, the test result will be displayed in few second on the application screen. 16. Wipe any excess blood on the finger with the cotton and dispose it properly. 17. Pull the test strip out of the Gluchobin. 18. Unscrew the adjustable tip of the lancet pen. 19. Place the protective cover of the lancet back on the lancet as shown below.      20. Discard the used lancet in an appropriate container. 21. Screw the adjustable tip back on the lancet pen. Note: Ensure that the test strip gets enough blood. Else try to use a new test strip to do the test again.  To avoid accidental injury, always remove the used lancet immediately after each test.  Blood Cholesterol Level Classification  Blood Cholesterol Classification Normal < 200 mg/dl Boundary line high 200-239 mg/dl High >240 mg/dl
B.O.L.T User Manual    Model No: VA06    22 © Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.  Body Mass Index (BMI) The Body Mass  Index (BMI) is  a  measure  of  relative  weight  based  on  an  individual's  mass  and height. BMI provides a simple numeric measure of a person's thickness or thinness, allowing health professionals to discuss overweight and underweight problems more objectively with their patients.  BMI Classification Please  note  that  this  table  can  give  only  a  generic  view.  Consult  with  your  physician  for  accurate assessment.  BMI Range Category <20 Under Weight 20-25 Normal Weight 25-30 Over Weight >30 Obesity  Measuring BMI with B.O.L.T  1. Choose Body Mass Index option from the application screen.  2. Enter  your  height  (feet/cm)  and  weight  (lbs/kg)  of  the  person  to  be  measured  in  the application. 3. On  successful  measurement,  the  BMI  value  is  displayed  which  can  be  compared  with  the above BMI range classification table.  Battery Care    Power adapter is included in the pack and the specifications are mentioned below. AC input: 100-240V, Frequency: 50Hz to 60Hz, 0.35A Max, DC output: +5V @ 2A    Connect the AC power adapter to the power source and micro USB port to the base unit`s USB Power socket.    Charge the base unit for minimum two hours during the first time usage.   The  mobile  application  indicates  the  battery  low  status  when  the  battery  level  goes  below 25% and shows critically low status when the battery level goes below 10%.    Charge  the  base  unit  using  the  power  adapter  and  view  the  charge  level  in  the  mobile application software.   It is  recommended to  unplug  the power adapter from  power source  when the charge level reaches 100%.   When  fully  charged  the  base  unit  will  automatically  cut  off  charging  internally,  thus  the device’s design has taken safety measures into account to face various abnormal conditions like over-charging, over discharging etc.
B.O.L.T User Manual    Model No: VA06    23 © Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.    When charging is needed, please connect the base unit to the power source using the power adapter.   The base unit can be operated by o   Connecting to power source  directly using  the power adapter    or o  Using  the charged inbuilt battery (adapter not required)             The device can work normally while charging. Replacement of Battery Pack Manufacturer highly recommended to change the battery of the base unit for every 1 year at the AMI authorized service center. Use AMI recommended battery for replacement. Replacement procedure 1.  Switch off the base unit before removing the back cover for the battery replacement. 2.  Remove the single screw on the upper portion of the battery cover as shown below.   3.  Press and remove the battery cover in the recommended direction as shown below.    4.  Disconnect the battery pack from the connector and replace with new one.
B.O.L.T User Manual    Model No: VA06    24 © Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.     5.  Install the battery cover and fasten with the screw.     6.  Connect the base unit with AC adapter and then charge for more than twelve hours before use.   Explanation of Indicators/Symbols Indicators/Symbols Function/Description    The indicator displays full battery power of the gadget in the computer/mobile device.       The indicator displays low battery power of the gadget in the computer/mobile device.  SYS  Systolic blood pressure in mmHg.  DIA   Diastolic blood pressure in mmHg.  PUL./min  Pulse per minute.       Flashing of the Bluetooth light indicates that the gadget is waiting for pairing with the mobile/tab.   Steady Bluetooth light indicates that the gadget is paired and ready for the measurement.                        Steady green light indicates that the gadget is operating in battery mode.  Blinking of green light indicates that the gadget has low battery
B.O.L.T User Manual    Model No: VA06    25 © Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.  level.                       Steady red light indicates that the gadget is in the charging mode.           Symbol for “ENVIRONMENT PROTECTION”            Symbol for “KEEP DRY”         Symbol for “MANUFACTURER”          Symbol for “MANUFACTURED DATE”         Symbol for “SERIAL NUMBER”       Symbol for “EUROPEAN REPRESENTATIVE”          Symbol for “COMPILES WITH MDD93/42/EEC REQUIREMENTS”                            Symbol for “Federal Communication Commission”           Symbol for “Read the documentation”          Symbol for “Warning”           Symbol for “Temperature limitation”           Symbol for “Shock Protection”
B.O.L.T User Manual    Model No: VA06    26 © Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.  Technical Specifications Product Name  B.O.L.T Model  VA06 Base Unit Base Unit Dimensions 130 (L) X 40.3 (H) X 75 (D) mm Base Unit Weight 220 grams (Including Battery) Power Source DC 5V 2A Bluetooth Bluetooth 4.0 EDR or Lower, Bluetooth Low Energy (BLE) Base Unit Operating Temperature 16°C to 35°C (60.8°F to 95.0°F) Base Unit Storage and Transport Temperature 10°C to 55°C (14°F to 131°F) Base Unit Storage Humidity 30%RH to 90%RH Non-Invasive Blood Pressure Blood pressure measurement method Oscillometric method with automatic inflation & measurement Cuff Pressure range 0 to  280 mmHg Pressure Accuracy ±4mmHg BP Pulse range 30 to 180 BPM Pulse Accuracy ± 5% Cuff Limb Circumference 22 cm to 42 cm Cuff Size 610 mm * 145 mm Cuff Weight 205 Grams IR Thermometer Body Temperature measurement method Tympanic, Infrared based Body temperature range 34°C to 42°C (93.2°F to 107.6°F) Body temperature Accuracy ±0.2°C (from 36°C to 39.0°C)/ ± 0.4°F(from 95.0°F to 102.6°F) ±0.3°C (from 39.1°C to 44.0°C)/ ± 0.5°F(from 102.38°F to 111.2°F) IRT Display resolution temperature range 0.1 °F IRT Unit Dimensions 84.8 (L) X 18 (H) X 26.6 (D) mm  (Highest width along the profile) IRT Unit Weight 42 grams Pulse Oximeter SpO2 measurement method Optical method SPO2 range 70% to 100%, below 70%:  Unspecified SpO2 Measurement Accuracy 70% to 100% - ±2%, below 70%:  Unspecified SpO2 Pulse Rate Range 30 to 180 BPM SpO2 Unit Dimensions 58.2 (L) X 35 (H) X 35.3 (D) mm SpO2 Unit Weight 60 grams Gluchobin Gluchobin measurement method Chronoamperometry method Glucose range 20-600mg/dL (1.11-33.3 mmol/L) Hemoglobin range 7 to 26 g/dL Cholesterol range 100 - 400 mg/dL Gluchobin Unit Dimensions 78 (L) X 27 (H) X 25(D) mm Gluchobin Unit Weight 18 grams  NOTE: These specifications are subject to change without notice. For more information kindly visit our website: www.amibolt.com
B.O.L.T User Manual    Model No: VA06    27 © Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.  Certifications COUNCIL DIRECTIVE 93/42/EEC of 14 June 1993 concerning medical devices. This device complies with the following normative documents:           EN ISO 10993-1:2009/AC: 2010 Biological evaluation of medical devices- Part1: Evaluation and Testing with in a risk management process.         EN ISO 10993-5:2009 Biological evaluation of medical devices - Part 5: Tests for in vitro   cytotoxicity         EN ISO 10993-10:2010 Biological evaluation of medical devices -- Part 10: Tests for irritation and skin sensitization         EN ISO 80601-2-61:2011 Particular requirements for basic safety and essential performance of pulse oximeter equipment         EN 80601-2-30:2010 Particular requirements for basic safety and essential performance of automated non-invasive sphygmomanometers         EN 12470-5:2003 Clinical thermometers - Part 5: Performance of infra-red ear thermometers          EN 60601-1:2012 General requirements for basic safety and essential performance        EN 60601-1-2-2007/AC: 2010 General requirements for safety -Collateral standard:  Electromagnetic compatibility.         EN 60601-1-6:2010 Collateral standard: Usability          IEC 60601-1-4:1996 General requirements for safety- Collateral standard: Programmable electrical medical systems.    1023    2AFV6-AMI-BU-02
B.O.L.T User Manual    Model No: VA06    28 © Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.  FCC compliance statements This device complies with Part 15 of the FCC Rules. Its operation is subject to the following two conditions:  (1)  This device may not cause harmful interference, and (2)  This  device  must  accept  any  interference  received,  including  Interference  that  may  cause undesired operation.   FCC Caution   Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. Part 15B compliance statements for digital devices: NOTE:  This  equipment  has  been  tested  and  found  to  comply  with  the  limits  for  a  Class  B  digital device,  pursuant  to  part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide  reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy And, if not installed and used in  accordance  with  the  instructions,  may  Cause  harmful  interference  to  radio  communications. However, there is no Guarantee that interference will not occur in a particular installation. If  this  equipment  does  cause  harmful  interference  to  radio  or  television  Reception,  which  can  be determined by turning the equipment off and on, The user is encouraged to try or to correct the interference by one or more of The following measures: —  Reorient or relocate the receiving antenna. —  Increase the separation between the equipment and receiver. —  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —  Consult the dealer or an experienced radio/TV technician for help.  For more information kindly visit our website: www.amibolt.com
B.O.L.T User Manual    Model No: VA06    29 © Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.   Warranty Information The B.O.L.T is warranted to be free from defects in materials and workmanship within one year from the  date  of  purchase  when  used  in  accordance  with  the  provided  instructions.  The  warranty  is extended only to the end user. The company will repair free of charge any part or parts of the product, if the defect is due to the faulty material or workmanship.   To obtain warranty service contact customer care support by calling 1800-419-9868.  Enclose  the  warranty  card,  Proof  of  Purchase.  Include  a  letter,  with  your  name,  address,  phone number,  and  description  of  the  specific  problem.  Pack  the  product  carefully to  prevent  damage  in transit.  Customer Care Support AMI’s flexible approach allows the customers to get Technical Support and Warranty services for B.O.L.T through our customer care support.    Toll free number (India): 1800–419–9868   Customer Care Support timings : 10am - 6pm Monday – Friday (Except National Holidays)  Contact us   AMERICAN MEGATRENDS INDIA PRIVATE LTD.,   KUMARAN NAGAR,   SEMMANCHERY VILLAGE,              CHENNAI (TN) 600119   Tel – (91) 44 66540922, Fax – (91) 44 66540901   Email: support@amibolt.com   Website: www.amibolt.com; www.amiindia.co.in
B.O.L.T User Manual    Model No: VA06    30 © Copyright 2015, All Rights Reserved. American Megatrends India Private Ltd.   American Megatrends International GmbH                     Truderingerstraße (Truderinger Strasse) 283                     81825 München (Munich), Deutschland (Germany)                     Tel: [49] 89 969995-10                     Support: [49] 89 969995-11                     Fax: [49] 89 969995-19                   Email: europesales@ami.com

Navigation menu