ADVEEZ PE3LR-TCH ACTIVE TAG User Manual

ADVEEZ ACTIVE TAG

User Manual

                               INSTRUCTIONS FOR USE  ACCESS CONTROL SYSTEM PE3LR  WANDER MONITORING AD-CARE Access Control Systems / Wander monitoring
   ADD-INS-PE3LR-CARE-ENG-31 Subject to change without noce   ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163  email: contact@adveez.com  31027 Toulouse Cedex 3 FRANCE Phoenix, AZ USA  +33(0)582082193 +1 602-549-7898      2 www.adveez.com                                                                             SUMMARY  PE3LR / AD-CARE  SYSTEM OVERVIEW    P. 1                                    WORKING  PRINCIPLE  SYSTEM COMPONENTS  - READERS/CONTROLLERS/SOFTWARE        P. 2  SYSTEM COMPONENTS  - TAGS / CARDS / AD-CARE-W WRIST        P. 4  PE3LR / AD-CARE STAND ALONE SYSTEM  DETAILS                                                         P. 6  Technical specicaons PE3LR-C / AD-CARE Stand-alone controller   P. 6  Wiring informaon PE3LR-C / AD-CARE Stand-alone controller        P. 7  Technical specicaons PE3LR-E external reader            P.10     POSITIONNING CONTROLLER / EXTERNAL ANTENNA                     P. 11  Single / Dual reader conguraon  Specic recommendaons / conguraons         Access Control Systems / Wander monitoring FCC - 15.21 NOTE: The user manual for an intenonal or unintenonal radiator shall cauon the user that changes or modicaons not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. (PE3LR-C / PE3LR-T/ PE3LR-TCH / AD-CARE-W) NOTE:   THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.
   ADD-INS-PE3LR-CARE-ENG-31 Subject to change without noce   ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163  email: contact@adveez.com  31027 Toulouse Cedex 3 FRANCE Phoenix, AZ USA  +33(0)582082193 +1 602-549-7898      1 www.adveez.com    The ADVEEZ PE3LR is a hands-free access control system that combines precision, long range and 3D detecon. It oers very con-venient and ecient access control via the ADVEEZ PE3RL-T card/tag which can be carried in a bag or pocket and sll be quickly idened. The PE3LR is ideal for upgrading tradional key pad and card swipe systems or applicaons where hands-free access is required including: clean rooms, hospitals, parking, entry automaon for disabled persons, etc. PE3LR system components are compact, robust and easy to install.  By creang precise detecon zones, the ADVEEZ system avoids misdetecon, which is the main drawback of exisng systems.  All ADVEEZ Readers supports 125 kHz, in addion to Adveez hands-free tags.  The PE3LR system is also compable with all types of electronic locks (magnec locks, electro-mechanic locks, motorized locks, etc.) and automac devices (motorized doors). It can be connected to exisng supervised access control systems as well.  ADVEEZ AD-CARE wander monitoring system is a variant of PE3LR system which takes advantage of the precise & robust ADVEEZ detecon. AD-CARE controllers can detect people wearing the AD-CARE-W wrist within a distance of 1 m up to 4 m. It can then send an alarm, lock the access to be monitored, send and alarm locally or remotely to pagers and access control net-work controllers. Hands free tags can be used for passing through monitored accesses with paents & clearing alarms automac ally. Main controller includes reading funcon . External antenna can extend main controller detecon zone.  Easy conguraon per soware of detecon zones, enrolling of cards, wander management wrist.                                                                             PE3LR / AD-CARE SYSTEM OVERVIEW         SIMPLE, FLEXIBLE, AND RELIABLE SOLUTION                                       ADVEEZ TECHNOLOGY ADVANTAGES         100% Hands Free Access: accurate, long range, compable with ADVEEZ & exisng OEM access control systems           AD-CARE WANDER MONITORING SYSTEM        DETECTION PRINCIPLE     PE3LR / AD-CARE Access Control Systems / Wander monitoring
   ADD-INS-PE3LR-CARE-ENG-31 Subject to change without noce   ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163  email: contact@adveez.com  31027 Toulouse Cedex 3 FRANCE Phoenix, AZ USA  +33(0)582082193 +1 602-549-7898      2 www.adveez.com                                                                             PE3LR / AD-CARE SYSTEM OVERVIEW INSTALLATION OVERWIEW PE3LR-C / AD-CARE-C main controller  Request to  Exit buon input (2 wires) PE3LR-E External antenna wiring (passive reader) (6 wires) Door contact input (2 wires) Addional contact  Relay output 2 (2 wires) Alarm, Display….. Magnec Lock Door strike Relay output 1 (2 wires) DATA INTERFACE OVERWIEW WIEGAND OUTPUT For connecon to access controllers (2 wires / Data0-Data1) Serial RS485 OUTPUT:   Connecon to ADVEEZ network controllers   Connecon to Nurse call systems (AD-CARE version)  (2 wires / Data0-Data1) Local connecon to PC for stand alone mode conguraon Access Control Systems / Wander monitoring
   ADD-INS-PE3LR-CARE-ENG-31 Subject to change without noce   ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163  email: contact@adveez.com  31027 Toulouse Cedex 3 FRANCE Phoenix, AZ USA  +33(0)582082193 +1 602-549-7898      3 www.adveez.com   ands-free Access Control System PE3LR                    SYSTEM COMPONENTS PE3LR / AD-CARE  INTERNAL READER—PE3LR-C / AD-CARE STAND-ALONE CONTROLLER EXTERNAL READER / ANTENNA PE3LR-E ORGANEEZ SUPERVISED ACCESS CONTROL MANAGEMENT (not described in present  doc.)  64000 event history / 10000 users / 128 readers / TCP-IP-R-485-Radio network                                            SYSTEM COMPONENTS— PE3LR/AD-CARE controller & PE3LR external antenna—FCC ID: R8T-PE3LR-C Hands-free Access Control – 1 access point 1024 cards in stand-alone version (64000 users in network version) Program cards directly with Master Card (PE3LR-MC) or management soware via PC– USB Cable The Internal Reader funcon PE3LR-C Door Controller allows: -Seng hands-free access or proximity (125 kHz) control in the secured zone on the external side without adding an addional Reader -Enrolling badges directly via the controller -Sensing movement direcon between PE3LR-C  internal Reader and PE3LR-E external Reader -Connecng to ADVEEZ supervised access control system in a wired  RS485 mode (Ref. P3LR-C-MC) or wire-less (ref. PE3LR-C-WL) -connecng to exisng third party access control systems via Wiegand output -connecng to nurse call systems (AD-CARE version)  - Waterproof and robust for outdoor installaon - addional Hands Free / detecon zone -  ADVEEZ PE3LR-T Hands-free tag reading - 125 KHz EM4100, 4200, 4450 Marin card reading Access Control Systems / Wander monitoring PE3LR-PLG-WANDER-MONITORING (AD-CARE) - Enroll & Delete cards / wrist - Download logged events - Congure access control (relay output) & alarm clear-PE3LR-PLG (PE3LR ACCESS CONTROL)   -  Enroll & Delete cards -  Download logged events -  Congure access control (relay output)  STAND ALONE CONFIGURATION SOFTWARE (not described in present document) This device (FCC ID : R8T-PE3LR-C) complies with part 15 of the FCC Rules. Operation is subject to the following two condi-tions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation” WARNING STATEMENT FOR MODULE: Because of the power level and grant condions of the Zig-Bee module, the 20cm separaon distance warning statement is need-ed. Please see below.: The antenna(s) used for this transmier must be installed to provide a minimum separaon distance of 20cm, and must not be co-located or operang in conjuncon with any other antenna or transmier.                                            FULL FUNCTION BENEFIT FROM PE3LR / AD-CARE WILL BE OBTAINED WITH FOLLOWING SOFTWARE
   ADD-INS-PE3LR-CARE-ENG-31 Subject to change without noce   ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163  email: contact@adveez.com  31027 Toulouse Cedex 3 FRANCE Phoenix, AZ USA  +33(0)582082193 +1 602-549-7898      4 www.adveez.com   Access Control Systems / Wander monitoring                                                             SYSTEM COMPONENTS PE3LR / AD-CARE                           SYSTEM COMPONENTS—CREDENTIALS HANDS-FREE CARD HOLDER PE3LR-TCH (FCC-ID: R8T-PE3LR-TCH*) HANDS-FREE TAG PE3LR-T (FCC-ID: R8T-PE3LR-T*)   Carries standard  swipe or RFID proximity ISO cards   CR2032 baery life: 2,000,000 hands-free tag acvaons   Combines hands-free access system with exisng swipe and magnec card    Dimensions: 86 mm / 54 mm / 0.76 mm   Black (ref:  RAL9004)    CR2032 baery life: 2,000,000 hands-free tag acvaons   Tag dimensions 74 mm/ 34 mm / 10 mm   Hands-free badge color opons:  Black (ref:  RAL9004), Grey (ref: RAL9006) - Red Master Tag PE3LR-T-MC enables programming tags  CAUTION:   Both hands free PE3LR-T & PE3LR-TCH work in proximity mode for access as well as for programming. Tags must be approached to PE3LR-C, AD-CARE-C & PE3LR-E ADVEEZ logo.   Once the tag has been programmed on the system ,  baery must be inserted or removed & re-inserted in order Inserng CR2032 baery Declip tag cap and insert baery in holder TORX SCREW DIAM. 2.5MM ×4 Inserng CR2032 baery: Remove cover (4 screws  -torx) and insert baery in holder  “This device (FCC ID : R8T-PERL3-TCH) complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any inter-ference received, including interference that may cause undesired operation”  “This device (FCC ID : R8T-PERL3-T) complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation”
   ADD-INS-PE3LR-CARE-ENG-31 Subject to change without noce   ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163  email: contact@adveez.com  31027 Toulouse Cedex 3 FRANCE Phoenix, AZ USA  +33(0)582082193 +1 602-549-7898      5 www.adveez.com                                              SYSTEM COMPONENTS—CREDENTIALS TORX SCREW DIAM. 2.5MM ×4 CAUTION:   AD-CARE-W wrist works in proximity mode for access as well as for programming. Tags must be approached to PE3LR-C, AD-CARE-C & PE3LR-E ADVEEZ logo.   Once  AD-CARE-W  wrist  has  been  programmed  on  the  system  ,    baery  must  be  inserted  or  removed  &  re-inserted in order to iniate tag rights. Access Control Systems / Wander monitoring                                                             SYSTEM COMPONENTS PE3LR / AD-CARE  AD-CARE-W WANDER MONITORING WRIST (FCC-ID: R8T-AD-CARE-W*) Inserng CR1632 baery: Remove cover (4 screws  -torx), remove printed circuit board from housing and insert baery in holder   CR1632 baery life: 2,000,000 wander monitoring  acvaons   Housing dimensions 52 mm/ 40 mm / 9,5 mm   White an-batcterial plasc housing   1 way white wrist material: Vinyl     Wrist width: 16 mm   “This device (FCC ID: R8T-AD-CARE-W) complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference re-ceived, including interference that may cause undesired operation”   FCC - 15.21 NOTE: The user manual for an intenonal or unintenonal radiator shall cauon the user that changes or modicaons not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. (PE3LR-C / PE3LR-T/ PE3LR-TCH / AD-CARE-W) NOTE:   THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.
   ADD-INS-PE3LR-CARE-ENG-31 Subject to change without noce   ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163  email: contact@adveez.com  31027 Toulouse Cedex 3 FRANCE Phoenix, AZ USA  +33(0)582082193 +1 602-549-7898      6 www.adveez.com                      PE3LR / AD-CARE Controller specicaons / mounng instrucons PE3LR-C / AD-CARE-C controller (FCC-ID : R8T-PE3LR-C*)  Stand alone door controller PE3LR-C / AD-CARE (health care variant) Programming via PC 2 frequency RF system Both ADVEEZ hands Free + 125 kHz EM cards supported 12V/24V power supply with no conguraon needed 200 mA average current draw / 1A peak Operang temperature : -20°C / +70°C Protecon class: IP54 Weight: 0.200 kg 10000 users 64000 event history RS485 network—radio network opon (PE3LR-C-WL) 2 relays / 1 door contact switch Mounng & Dimensions  Mounng (cauon: avoid mounng close to 125kHz proximity card readers):  1) Fit all cables with terminal appropriate terminal blocks  according wiring details in page 3 2) Mount the back cover on the wall (4 screws) and let the  Cables ed with the terminal blocks go through the back cover 3) Connect all the terminal blocks on the printed circuit board according to wiring diagram page 3. 4) Mount and screw the front cover unit on the back cover 4 screws -  4×60 mm  4 S6 wall plugs Access Control Systems / Wander monitoring “This device (FCC ID : R8T-PE3LR-C) complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation” WARNING STATEMENT FOR MODULE: Because of the power level and grant condions of the Zig-Bee module, the 20cm separaon distance warning statement is need-ed. Please see below.: The antenna(s) used for this transmier must be installed to provide a minimum separaon distance of 20cm, and must not be co-located or operang in conjuncon with any other antenna or transmier.
   ADD-INS-PE3LR-CARE-ENG-31 Subject to change without noce   ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163  email: contact@adveez.com  31027 Toulouse Cedex 3 FRANCE Phoenix, AZ USA  +33(0)582082193 +1 602-549-7898      7 www.adveez.com   Block 1 – BLUE– 4 Pins – POWER SUPPLY –RTE buon Pin 1: Tx1  Pin 2: Tx2 Pin 3: LED Green Pin 4:  LED red Pin 5: GROUND Pin 6: RX Block 2 – GREY- 6 Pins –  2 Relay / Door contact Pin 1: RS485-B  Pin 2: RS485-A  Pin 3: GROUND  Pin 4: Door Contact Pin 5: DATA 1 - Wiegand  Pin 6: DATA 0 - Wiegand  Block 3 – GREY - 6 contacts - COMMUNICATION Pin 1: Relay– NO2 Pin 2: Relay - C2 Pin 3: Relay– NC2 Pin 1: Relay– NO1 Pin 2: Relay- C1 Pin 3: Relay – NC1 Block 4 – GREY– 6 contacts External Antenna Pin 1: 12V/24V  Pin 2:  GROUND Pin 3: Request To Exit buon +  Pin 4: Request To Exit buon -  Jumper conguraon U17 : Inline switches for indexing controllers  J3 OFF + J4 OFF single internal antenna acvaon  J3 ON + J4 OFF   Both internal & external antennas acvated J3 OFF + J4 ON         Single external antenna acvaon J3 ON + J4 ON  Internal & external readers acvated—ltering of misdetec-ons in secured zone acvated J2 ON: long range—internal antenna   J6 ON: acvaon buzzer J1 ON:  long range acvaon external antenna  J7 ON:  acvaon de la LED interne J5 ON: Red LED acvated                  WIRING INFORMATION—TERMINAL BLOCK DETAILS PE3LR/AD-CARE Controller Jumper OFF Jumper ON 1 1 1 B3 B4 B2 B1 U17 Reset Buon    Connector for USB-PC communicaon Access Control Systems / Wander monitoring
   ADD-INS-PE3LR-CARE-ENG-31 Subject to change without noce   ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163  email: contact@adveez.com  31027 Toulouse Cedex 3 FRANCE Phoenix, AZ USA  +33(0)582082193 +1 602-549-7898      8 www.adveez.com                     Wiring informaon - PE3LR/AD-CARE interface to access CTL & nurse call BLOCK 3 : NURSE CALL (ESPA4.4.4  output or POCSAG TEXT or ASCII) Select ck box ESPA4.4.4 orPOCSAG TEXT or ASCII  raw data depending on device used Monitored access can be named Pager Adress / groups can be selected for ESPA communicaon mode. Protocole conguraon depending on device downstream of AD-CARE controller : Pin 1: RS485-B  Pin 2: RS485-A  Pin 3: GROUND  Contacteur de porte Pin 4: DATA 1 - Wiegand  Access control—door controllers Pin 5: DATA 0 - Wiegand  Access control—door controllers RS485-RS232             TX Converter                   RX 446MHz Access Control Systems / Wander monitoring
   ADD-INS-PE3LR-CARE-ENG-31 Subject to change without noce   ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163  email: contact@adveez.com  31027 Toulouse Cedex 3 FRANCE Phoenix, AZ USA  +33(0)582082193 +1 602-549-7898      9 www.adveez.com   WIRING INFORMATION—PE3LR / AD-CARE—LOCKING DEVICES / RELAYS / POWER SUPPLY Pin 1: Relay – NO2 Pin 2: Relay - C2 Pin 3: Relay – NC2 Pin 1: Relay – NO1 Pin 2: Relay - C1 Pin 3: Relay – NC1 0V/-PWR Block 2 – GREY - 6 contacts –  2 Relay / Contacts—Door strike conguraon (NO) 12V/+Alim Intrusion—Alarm wiring depends on device Manufaturer / type + door strike Pin 1: Relay – NO2 Pin 2: Relay - C2 Pin 3: Relay – NC2 Pin 1: Relay – NO1 Pin 2: Relay - C1 Pin 3: Relay – NC1 0V/-PWR Block 2 – GREY - 6 contacts –  2 Relay / Contacts—Magnec Lock conguraon (NC—permanently supplied) 12V/+PWR Intrusion—Alarm wiring depends on device Manufaturer / type + magnec lock Pin 1: 12V/24V  Pin 2:  GROUND  Pin 3: RTE Buon +  Pin 4: RTE Buon -  + ALIM - ALIM +  - Block 1 – BLUE– 4 contacts – POWER SUPPLY –RTE Access Control Systems / Wander monitoring
   ADD-INS-PE3LR-CARE-ENG-31 Subject to change without noce   ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163  email: contact@adveez.com  31027 Toulouse Cedex 3 FRANCE Phoenix, AZ USA  +33(0)582082193 +1 602-549-7898      10 www.adveez.com   WIRING INFORMATION PE3LR / AD-CARE *Internal and External door control  PE3LR-C-MC  12V / 24V PE3LR-E Reading of hands free card PE3LR-T with high reading distance accuracy PE3LR-E enables extending detecon zone by connecng it to PE3LR-C Mounng on standard wall box– 2 screws (minimum distance from a metal surface: 5 cm) (cauon: avoid mounng close to 125kHz proximity card readers) Connecon via removable terminal block 2 colors (red/green) LED actuaon Mul technology antenna  PE3LR-E EXTERNAL READER (FCC-ID : R8T-PE3LR-C*) Removable terminal block details Block 1 – Grey - 6 ways – Internal Reader PIN# 1: green LED PIN# 2: red LED PIN# 3: Ground LED PIN# 4: Tx1 PIN# 5: Tx2 PIN# 6: Rx1 External reader backside view / terminal block pin ordering details Mounng  2 screws 4 mm × 60 mm on a standard recessed conduit box  67 mm diameter and 40 mm depth Access Control Systems / Wander monitoring  “This device (FCC ID : R8T-PE3LR-C) complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation”
   ADD-INS-PE3LR-CARE-ENG-31 Subject to change without noce   ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163  email: contact@adveez.com  31027 Toulouse Cedex 3 FRANCE Phoenix, AZ USA  +33(0)582082193 +1 602-549-7898      11 www.adveez.com   PE3LR-C is posioned on entry on the  inside wall or on the outside wall          depending on wall metal content  Zone to be secured The access control can work with the single door  controller/internal reader. The following drawing shows the detecon zone  inside the ring. In this conguraon, the access control works in both  direcon (internal and external). The door controller / internal reader PE3LR-C must be placed  in the secured zone to prevent any risk of aack towards controller. There is then no outside indicaon of idencaon Bi-reader conguraon : external an-vandal device  Secured Zone/Outside view– PE3LR-E  Inside view– PE3LR-C Door controller Installaon External Reader Installaon                        Single-reader conguraon - PE3LR-C / AD-CARE   External Reader Internal Reader/ Door controller Internal Reader/ Door controller  Door reader   Cable/External reader   Door contact switch Electric lock Access Control Systems / Wander monitoring
   ADD-INS-PE3LR-CARE-ENG-31 Subject to change without noce   ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163  email: contact@adveez.com  31027 Toulouse Cedex 3 FRANCE Phoenix, AZ USA  +33(0)582082193 +1 602-549-7898      12 www.adveez.com   PE3LR-E located on the entrance      ZONE 1 ZONE 2 Sensing movement direcon via PE3LR-C door controller Drawing below shows 2 separated zones, each being ed with 1 external reader close to entrance and 1 controller/internal reader inside. Door controller’s jumper J1 is acvated so that reader funcon gets acvated. Door controller’s jumper J4 is deacvated so that access control is not acve on exit.  If card bearer wants to enter zone 1 with authorized card, his card is detected while  Filtering misdetecons inside the secured zone Inhibing the detecon in a given area Door controller’s dipswitch J1 is acvated so that reading funcon is acve. A switch contact of exit request  is connected to the Block 4. The  dipswitch J4 of door controller is deacvated to disable the access control in exit.  If  card  bearer  being  situated  in  zone  1  with  authorized  card  wishes  to  pass  the  door (controlled door) of the zone without going out, his card is detected in the intersecon between  green  and  orange  detecon  zones.  The  controller/internal  reader  will  then idenfy the passage of PE3LR-E reader  in the internal detecon zone avoiding to unlock the access. Posioning readers of two dierent accesses Two dierent detecon ranges can be congured on PE3LR-C The detecon range in short distance (dipswitch J1 or J2  deacvated) is 1.5 m. The detecon range in long distance (dipswitch J1 or J2 acvated) is 3 m. PE3LR-C controller Located in the zone to be secured Access Control Systems / Wander monitoring
   ADD-INS-PE3LR-CARE-ENG-31 Subject to change without noce   ADVEEZ, Bat MEAS - Impasse Jeanne Benozzi CS 83163  email: contact@adveez.com  31027 Toulouse Cedex 3 FRANCE Phoenix, AZ USA  +33(0)582082193 +1 602-549-7898      13 www.adveez.com   Hands-free access control system PE3LR ADVEEZ SUPERVISED SYSTEM  : connecng PE3LR & AD-CARE controllers  Manage Access authorizaon for all card types Control 128 doors in Radio / RJ-45 / RS-485 mode In the radio mode, each Controller PE3LR-C-NT is a network access point Central access control management: users, credenals, readers, etc. Event history recording - 64000 per access controller Connecng the Network controller to the PC via USB cable           TECHNICAL SPECIFICATIONS PE3LR-NT NETWORK CONTROL  ACCESS CONTROL SOFTWARE  -Program / Delete credenals, users, readers -Manage Administrators rights -Manage me intervals, schedules and holidays -Congure Hands-free access control:   Relay acvaon duraon   Detecon distance Soware supplied on a USB drive with a USB cable and installaon guide PE3LR-C-NT  12V / 24V PE3LR-E   Administrative PC RS-485 / USB PE3LR-NT *ADVEEZ Connecon *Radio / RJ-45/ RS-485 Transmission  *Door control funcon  Radio / RJ-45 / RS-485 PE3LR-NT

Navigation menu