ADRF KOREA ADX-R-78P DAS (Distributed Antenna System) User Manual Rev3 Part2

ADRF KOREA, Inc. DAS (Distributed Antenna System) Rev3 Part2

Contents

User Manual Rev3_Part2

AdvancedRFTechnologies,Inc.  465. MOUNTINGMETHOD5.1 HeadEnd5.1.1 RackMountFigure5‐1HERackMount(Front&Rearview) Expandableupto4OPTs,4BCUsand2AUXCHsSDPOWERSOFT FAIL-HSOFT FAIL-RHARD FAIL-HHARD FAIL-RLINK FAIL-HLINK FAIL-RHOST HE VIEWREMOTE RU VIEWDL OUTUL INHARD FAILDL SIG LOWSOFT FAILPOWERDL OUTUL INHARD FAILDL SIG LOWSOFT FAILPOWERDL OUTUL INHARD FAILDL SIG LOWSOFT FAILPOWERDL OUTUL INHARD FAILDL SIG LOWSOFT FAILPOWERUL1 UL2 UL3 UL4DL1 DL2 DL3 DL4UL5UL6UL7UL8DL5DL6DL7DL8LD FAIL5-8 LINK5 LINK6 LINK7 LINK8LD FAIL1-4 LINK1 LINK2 LINK3 LINK4POWERSOFT FAILPOWERPOWERCHG STSLOW BATTAC FAILDC FAILLD FAIL5-8 LINK5 LINK6 LINK7 LINK8LD FAIL1-4 LINK1 LINK2 LINK3 LINK4POWERLD FAIL5-8 LINK5 LINK6 LINK7 LINK8LD FAIL1-4 LINK1 LINK2 LINK3 LINK4POWERLD FAIL5-8 LINK5 LINK6 LINK7 LINK8LD FAIL1-4 LINK1 LINK2 LINK3 LINK4POWERSOFT FAILPOWERSOFT FAILPOWERSOFT FAILPOWERSDDL IN UL OUTDPXDL IN UL OUTDPXDL IN UL OUTDPXDL IN UL OUTDPXUL5UL6UL7UL8DL5DL6DL7DL8UL1UL2UL3UL4DL1DL2DL3DL4OPT 1 OPT 2OPT 3 OPT 4BAND COM 1 BAND COM 2BAND COM 3 BAND COM 4AUX_CH 1AUX_CH 2OFFVHF UL 2 UL O UT 2 VHF DL 2 DL IN 2LINK 8 LINK 7 LINK 6 LINK 5VHF UL 1 UL OUT 1 VHF DL 1 DL IN 1LINK 4 LINK 3 LINK 2 LINK 1OPTVHF UL 2 UL O UT 2 VHF DL 2 DL IN 2LINK 8 LINK 7 LINK 6 LINK 5VHF UL 1 UL OUT 1 VHF DL 1 DL IN 1LINK 4 LINK 3 LINK 2 LINK 1OPTVHF UL 2 UL O UT 2 VHF DL 2 DL IN 2LINK 8 LINK 7 LINK 6 LINK 5VHF UL 1 UL OUT 1 VHF DL 1 DL IN 1LINK 4 LINK 3 LINK 2 LINK 1OPTVHF UL 2 UL O UT 2 VHF DL 2 DL IN 2LINK 8 LINK 7 LINK 6 LINK 5VHF UL 1 UL OUT 1 VHF DL 1 DL IN 1LINK 4 LINK 3 LINK 2 LINK 1OPTDL IN 3BAND COMCH3 CH2 CH1 SUMDPX 3 UL OUT 3 DL IN 2 DPX 2 UL OUT 2 DL IN 1 DPX 1 UL OUT 1 DL OUT UL INDL IN 3BAND COMCH3 CH2 CH1 SUMDPX 3 UL OUT 3 DL IN 2 DPX 2 UL OUT 2 DL IN 1 DPX 1 UL OUT 1 DL OUT UL INDL IN 3BAND COMCH3 CH2 CH1 SUMDPX 3 UL OUT 3 DL IN 2 DPX 2 UL OUT 2 DL IN 1 DPX 1 UL OUT 1 DL OUT UL INDL IN 3BAND COMCH3 CH2 CH1 SUMDPX 3 UL OUT 3 DL IN 2 DPX 2 UL OUT 2 DL IN 1 DPX 1 UL OUT 1 DL OUT UL INOFFBATTERY INSTALLBATTER YBATTERYAC SELECT OFF/ONAC INS/WOFF ON24V      1A
AdvancedRFTechnologies,Inc.  475.1.2 WallMountFigure5‐2HEWallMount(TopView) Expandableupto3units(OPT,BCU)ormax3U(132mm)‐ ODURackorBCUwillbestackedupabovebasic19”HEchassiswhichincludesNMS,RFU,PSUandCHCPOWERSOFT FAIL-HSOFT FAIL-RHARD FAIL-HHARD FAIL-RLINK FAIL-HLINK FAIL-RPOWERCHG STSLOW BATTAC FAILDC FAIL
AdvancedRFTechnologies,Inc.  485.2 RemoteUnit5.2.1 RackMountFigure5‐3RURackMount(Frontview)POWERCHG-STSLOW BATTAC FAILDC FAIL
AdvancedRFTechnologies,Inc.  495.2.2 WallMount5.2.2.1 RemoteUnitusingRUChassis(ADX‐R‐CHA‐30)WallmountbracketsattachedtotheindividualremotemodulesmustberemovedbeforeslidingtheremotemodulesintotheRUChassis.Figure5‐419”Shelftype‐RUWallMount(Topview)5.2.2.2 IndividualRemoteModuleRemotemodulescanbemountedusingtheattachedmountingbracketthatshipswiththeunit.Figure5‐5RemoteModuleWallMount(Topview)SERVERUL1 UL2 UL3 UL4DL1 DL2 DL3 DL4M-DLM-ULCPL(-30dB)E-DLE-ULVHF DL VH F ULEF-DL IN EF-DL OUTEF-UL INEF-UL OUTPOWERCHG-STSLOW BATTAC FAILDC FAILDL INSERVERCPL(-30dB)UL OUTEF-DL OUT EF-DL IN EF-UL IN EF-UL OUTDL INSERVERCPL(-30dB)UL OUTEF-DL OUT EF-DL IN EF-UL IN EF-UL OUTDL INSERVERCPL(-30dB)UL OUTEF-DL OUT EF-DL IN EF-UL IN EF-UL OUTDL INSERVERCPL(-30dB)UL OUTEF-DL OUT EF-DL IN EF-UL IN EF-UL OUTDL4 DL3 DL2 DL1 ADX-R -4WS UL4 UL3 UL2 UL1M-ULM-DLDL INSERVERCPL(-30dB)UL OUTEF-DL OUT EF-DL IN EF-UL IN EF-UL OUT
AdvancedRFTechnologies,Inc.  506. INSTALLATION6.1 Pre‐InstallationInspectionPleasefollowtheseproceduresbeforeinstallingADXequipment:o Verifythenumberofpackagesreceivedagainstthepackinglist.o Checkallpackagesforexternaldamage;reportanyexternaldamagetotheshippingcarrier.Ifthereisdamage,ashippingagentshouldbepresentbeforeyouunpackandinspectthecontentsbecausedamagecausedduringtransitistheresponsibilityoftheshippingagent.o Openandcheckeachpackageagainstthepackinglist.Ifanyitemsaremissing,contactADRFcustomerservice.o Ifdamageisdiscoveredatthetimeofinstallation,contacttheshippingagent.o VerifytheACvoltagewithDVM(Voltmeter),thenselecttheeither110Vor220VACusingtheselectionswitchlocatedattherearofHEandRUPSU.TheADXshipswiththeACselectionswitchsettothe110Vposition.IncorrectACselectioncandamagetheADXequipment.6.2 ADXDASInstallationProcedure6.2.1 HEInstallationProcedure CAUTION: ADXDASHEshouldbeinstalledinsidebuildingonly.  6.2.1.1 InstallingaADXDASHEinarackTheADXHEchassismountsinastandard19”(483mm)equipmentrack.Allowclearanceof3”(76mm)atthefrontandrear,and2”(51mm)onbothsidesforaircirculation.Notoporbottomclearanceisrequired. Consideration:‐ Eightmountingholesarelocatedon4cornersofADXHEtoattachittothe19”rack.TheADXHEmustbesecurelyattachedtoarackthatcansupporttheweightoftheADX. Mountprocedure‐ ThefollowingstepsshouldbefollowedwhilemountingtheADXHE DetachthewallmountbracketassembledlocatedatthebaseoftheADX‐HEchassis VerifythattheHEandMountingholesareingoodcondition SettheADXDASHEagainstthe19”rackandsecuretheunitwithscrews VerifythatADXHEissecurelyattached ConnecttheGNDcable ConnecttheRFcable ConnectthePower ConnecttheOpticcable
AdvancedRFTechnologies,Inc.  51Figure6‐1ADXHE19”RackMountInstructions
AdvancedRFTechnologies,Inc.  526.2.1.2 WallmountingtheADXDASHEIftheADXHEchassisisbeingmountedtoawall,thenallowclearanceofatleast17”(430mm)onthetop(frontsideofHE)and2”(51mm)onthebottom(rearsideofHE)and2”(51mm)onbothsidesandfrontforaircirculation. Mountprocedure‐ ThefollowingstepsshouldbefollowedwhenwallmountingtheADXHE VerifythattheHEandMountingholeareingoodcondition PlacetheADXHEagainstthewallandmarkofthemountingholes Drillholes(4holes,18Φmm,50mmdepth)intheinstallationsurfaceandinserttheanchorbolts BolttheADXHEtothewall MakesuretheADXHEissecurelyattached ConnecttheGNDcable ConnecttheRFcable ConnectthePower ConnecttheOpticcableFigure6‐2ADXHEWallMountInstructions
AdvancedRFTechnologies,Inc.  536.2.1.2.1 InstallingaddedracktypemodulesintobasicHEchassisAdditionalmodulessuchastheADX‐H‐RACK‐ODUandADX‐H‐BCUcanbemountedtotheChassis(ADX‐H‐CHA)usingtheincludedmountingbracketsthatcomewiththeadd‐onmodules. Amaximumofupto3addonmodules(OPT,BCU)canbemountedtothechassis‐ ODURackorBCUwillbestackedupabovebasic19”HEchassiswhichincludesNMS,RFU,PSUandCHCFigure6‐3WallMountInstructionsforADX‐HEadded1UUnit 
AdvancedRFTechnologies,Inc.  546.2.2 RUInstallationProcedure CAUTION: ADXDASRUshouldbeinstalledinsidebuildingonly.  6.2.2.1 InstallingaADXDASRUinarackIftheADXRUchassisisbeingwallmountedthenallowclearanceof3”(76mm)frontandrear,and2”(51mm)onbothsidesforaircirculation.Notoporbottomclearanceisrequired.WhenADXDASRUmountsinastandard19”equipmentrack,rackorwalltypefanisneededforheatdissipation.Theracktypefan(ADX‐R‐FAN)musthaveatleast1.75"ofclearance. Consideration:‐ Eightmountingholesarelocatedon4cornersofADXRUtoattachittothe19”rack.TheADXRUmustbesecurelyattachedtosupporttheweightoftheADX‐RUunits. Mountprocedure‐ ThefollowingstepsshouldbefollowedwhilemountingtheADX‐RUunits DetachthewallmountbracketlocatedatthebaseoftheADX‐RUchassis VerifythattheRUandMountingholeareingoodcondition ScrewtheADXDASRUtothe19”rack MakesuretheADXRUissecurelyattached ConnecttheGNDcable ConnecttheRFcable ConnectthePower ConnecttheOpticcable
AdvancedRFTechnologies,Inc.  55Figure6‐4ADX‐RU19”RackMountInstructions
AdvancedRFTechnologies,Inc.  566.2.2.2 WallmountingtheADXDASRUIftheADXRUchassisisbeingmountedtoawall,thenallowclearanceofatleast16”(406mm)onthetop(frontsideofRU),2”(51mm)onthebottom(rearsideofRU)and2”(51mm)onbothsidesandfrontforaircirculation. Mountprocedure‐ ThefollowingstepsshouldbefollowedwhilemountingtheADXRU VerifythattheRUandMountingholeareingoodcondition PlacetheRUchassisupagainstthewallandmarkoffthemountingholes Drillholes(4holes,18Φmm,50mmdepth)intheinstallationsurfaceandinserttheanchorbolts BolttheRUchassistothewall InstalltheindividualSub‐RUinsideofthechassis MakesuretheRUchassisissecurelyattached ConnecttheRFcable ConnecttheAntennacable ConnectthePower ConnecttheOpticcableFigure6‐5ADX‐RUWallMountInstructions
AdvancedRFTechnologies,Inc.  576.2.2.2.1 InstallingaddedracktypemodulesintobasicHEchassisAdditionalmodulessuchastheADX‐R‐CHC(channelcombiner)andADX‐R‐PSU(powersupplyunit)canbemountedtotheChassis(ADX‐R‐CHA)usingtheincludedmountingbracketsthatcomewiththeadd‐onmodules. Amaximumofupto2addonmodules(ADX‐R‐CHCandADX‐R‐PSU)canbemountedtothechassis.‐ ADX‐R‐PSUorADX‐R‐CHCwillbestackedupabovebasic19”RUchassiswhichholdstheMaster/SlaveRUunits.Figure6‐6WallMountInstructionsforADX‐RUadded1.5UUnit
AdvancedRFTechnologies,Inc.  586.2.2.3 WallmountinganADXRemoteModule Mountprocedure‐ ThefollowingstepsshouldbefollowedwhilemountingtheRemoteModule VerifythattheRUandMountingholeareingoodcondition SeparatethewallmountbracketfromtheSub‐RU Placedthewallmountbracketagainstthewallandmarkoffthemountingholes Drillholes(4holes,6Φmm)intheinstallationsurfacetheninserttheenclosedanchorbolts Boltthemountingbrackettothewall InstalltheSub‐RUtothemountingbracket FastentheSub‐RUtothemountingbracketusingtheincludedscrews VerifythattheRemoteModuleissecurelyattached ConnecttheAntennacable ConnectthePower ConnecttheOpticcable(ifapplicable)Figure6‐7RemoteModuleWallMountInstructions 
AdvancedRFTechnologies,Inc.  596.2.3 ADX‐H‐OEUInstallationProcedure CAUTION: ADX‐H‐OEUshouldbeinstalledinsidebuildingonly.  6.2.3.1 InstallingaADX‐H‐OEUinaRackTheADX‐H‐OEUmountsinastandard19”(483mm)equipmentrack.Allowclearanceof3”(76mm)frontandrear,and2”(51mm)onbothsidesforaircirculation.Notoporbottomclearanceisrequired. Consideration:‐ Fourmountingholesarelocatedon4cornersofADX‐H‐OEUtoattachittothe19”rack.TheADX‐H‐OEUmustbesecurelyattachedtosupporttheweightoftheunit. Mountprocedure‐ ThefollowingstepsshouldbefollowedwhilemountingtheADX‐H‐OEU DetachthewallmountbracketslocatedatthebaseoftheADX‐H‐OEU VerifythattheOEUandmountingholeareingoodcondition ScrewtheADX‐H‐OEUtothe19”rack MakesuretheADX‐H‐OEUissecurelyattached ConnecttheGNDcable ConnecttheRFcable ConnectthePower ConnecttheOpticcable
AdvancedRFTechnologies,Inc.  60Figure6‐8ADX‐H‐OEURackMountInstructions
AdvancedRFTechnologies,Inc.  616.2.3.2 WallmountingtheADX‐H‐OEU Mountprocedure‐ ThefollowingstepsshouldbefollowedwhilemountingtheADX‐H‐OEU  VerifythattheOEUandMountingholeareingoodcondition Drillholes(4holes,6Φmm)intheinstallationsurfacetheninserttheenclosedanchorbolts SettheADX‐H‐OEUagainstthewall MakesuretheOEUissecurelyattached ConnecttheRFcable ConnecttheAntennacable ConnectthePower ConnecttheOpticcable Figure6‐9ADX‐H‐OEUWallMountInstructions
AdvancedRFTechnologies,Inc.  626.3 GroundingAgroundcableisincludedinthebox.ThegroundingterminalsarelocatedattherearoftheADXHEandRU.Thegroundingcableshouldbeproperlyconnectedbeforepoweringontheequipment. Figure6‐10GroundCableConnection(HErearside)Figure6‐11GroundCableConnection(RUrearside)OPT 1 OPT 2OPT 3 OPT 4BAND COM 1 BAND COM 2BAND COM 3 BAND COM 4AUX_CH 1AUX_CH 2BATTERY INSTALLBATTERY 24V BATAC POWERSOFT FAILHARD FAIL
AdvancedRFTechnologies,Inc.  636.4 OpticPortCleaning Werecommendcleaningopticconnectorusingadryopticalcleaningswabortissueinadryenvironmentasneeded.WerecommendcleaningtheopticconnectorsonlyiftheexpectedopticlossishigherthanthelossreportedintheWeb‐GUIby1.5dBo.(Figure6‐12) Whenopticconnectorarenotinuse,theportshouldbecoveredwithaprotectivedustcap.(Figure6‐13)Figure6‐12OpticConnectorCleaning(left)andOpticPortCleaning(right)Figure6‐13SC/APCOpticConnectorDustCap
AdvancedRFTechnologies,Inc.  647. WARRANTYANDREPAIRPOLICY7.1 GeneralWarrantyTheADXcarriesaStandardWarrantyperiodoftwo(2)yearsunlessindicatedotherwiseonthepackageorintheacknowledgmentofthepurchaseorder.7.2 LimitationsofWarrantyYourexclusiveremedyforanydefectiveproductislimitedtotherepairorreplacementofthedefectiveproduct.AdvancedRFTechnologies,Inc.mayelectwhichremedyorcombinationofremediestoprovideinitssolediscretion.AdvancedRFTechnologies,Inc.shallhaveareasonabletimeafterdeterminingthatadefectiveproductexiststorepairorreplacetheproblemunit.AdvancedRFTechnologies,Inc.warrantyappliestorepairedorreplacedproductsforthebalanceoftheapplicableperiodoftheoriginalwarrantyorninetydaysfromthedateofshipmentofarepairedorreplacedproduct,whicheverislonger.7.3 LimitationofDamagesTheliabilityforanydefectiveproductshallinnoeventexceedthepurchasepriceforthedefectiveproduct.7.4 NoConsequentialDamagesAdvancedRFTechnologies,Inc.hasnoliabilityforgeneral,consequential,incidentalorspecialdamages.7.5 AdditionalLimitationonWarrantyAdvancedRFTechnologies,Inc.standardwarrantydoesnotcoverproductswhichhavebeenreceivedimproperlypackaged,altered,orphysicallydamaged.Forexample,brokenwarrantyseal,labelsexhibitingtampering,physicallyabusedenclosure,brokenpinsonconnectors,anymodificationsmadewithoutAdvancedRFTechnologies,Inc.authorization,willvoidallwarranty.7.6 ReturnMaterialAuthorization(RMA)NoproductmaybereturneddirectlytoAdvancedRFTechnologies,Inc.withoutfirstgettinganapprovalfromAdvancedRFTechnologies,Inc.Ifitisdeterminedthattheproductmaybedefective,youwillbegivenanRMAnumberandinstructionsinhowtoreturntheproduct.Anunauthorizedreturn,i.e.,oneforwhichanRMAnumberhasnotbeenissued,willbereturnedtoyouatyourexpense.AuthorizedreturnsaretobeshippedtotheaddressontheRMAinanapprovedshippingcontainer.Youwillbegivenourcourierinformation.ItissuggestedthattheoriginalboxandpackagingmaterialsshouldbekeptifanoccasionariseswhereadefectiveproductneedstobeshippedbacktoAdvancedRFTechnologies,Inc.TorequestanRMA,pleasecall(800)313‐9345orsendanemailtotechsupport@adrftech.com.
AdvancedRFTechnologies,Inc.  658. WEB‐GUI8.1 Web‐GUISetupTheWeb‐GUIallowstheusertocommunicatewiththeDASsystemeitherlocallyorremotely.ToconnecttotheDASsystemlocally,youwillneedalaptopwithanEthernetportandaRJ‐45crossovercable.ToconnecttotheDASsystemremotely,youwillneedtohaveanactiveinternetconnectionandtheADXsystemmusthaveandexternalmodemboxconnectedtotheADX.8.1.1 DASsystem/PCConnectionUsingWeb‐GUI VerifythatyourLocalAreaConnectionissettoObtainanIPaddressautomaticallyundertheInternetProtocol(TCP/IP)properties‐ Ifyouareconnectingtotheunitremotely(useofamodem),thenskipthisandnextstep. ConnecttheRJ‐45crossovercablebetweenthelaptop’sEthernetportandtherepeater’sEthernetport LaunchanInternetBrowser TypethefollowingIPaddressintotheaddressbarofMicrosoftInternetExplorer:http://192.168.63.1‐ Ifyouareconnectingtotheunitremotely,thentypetheIPaddressofthemodemtoconnecttotheunit Thefollowingloginscreenwillappear:Figure8‐1LoginscreenIfyouarenottheAdministrator,pleasetypeinyourassignedusername&passwordwhichyoushouldhavereceivedfromtheAdministrator.Table8‐1AccountInformationforLoginAccounttypeShowitemsControlItemsDefaultIDDefaultPasswordAdministratorallItems allitems admin adminUserrestricteditemsrestricteditems adrf adrfGuestrestricteditemsread‐only guest guest
AdvancedRFTechnologies,Inc.  668.2 Administrator/UserMode8.2.1 Common8.2.1.1 NavigationtreeLock/UnlockWhenthesystemis“Locked”,agreenlockiconwillappearabovethenavigationtree.Whenthesystemislocked,newdevicescannotbeadded.Anydevicesaddedtothesystemwhenthesystemis“Locked”willnotbedetectedbytheNMS.Afterasystemhasbeencommissionedproperly,thesystemshouldbeleftinthe“Locked”position.Tounlockthesystem,clickonthe“UnlockSystem”buttontotherightoftheicon.Whenthesystemis“Unlocked”,anorangeiconwillappearabovethenavigationtree.Whenthesystemisunlocked,newdevicesaddedtothesystemwillbeautomaticallydetected.Oncethenewhardwareappearsinthesystemtree,thenthesystemcanbelocked.Tolockthesystem,clickonthe“LockSystem”buttontotherightoftheicon.Figure8‐2NavigationtreeLock/Unlock8.2.1.2 NavigationTreeFigure8‐3NavigationtreeThenavigationtreelocatedonthelefthandsideoftheWeb‐GUIallowstheusertoswitchbetweenthevariousmodulesthatareconnectedtothesystem.Table8‐2NavigationtreeParametersDescriptionExpands theentirenavigationtreeCollapses theentirenavigationtreeThemodulehastheexpandablesubordinate modulesThebranchiscurrentlyexpandedThemodulehassoftfailalarmThemodulehashardfailalarmThemodulehasnoalarms(normal)Theselectedmodulewillhaveorangecoloredtext
AdvancedRFTechnologies,Inc.  678.2.1.3 PowerStatusDisplaythepowersourcethatiscurrentlybeingused.Table8‐3PowerSupplyStatusInputPowerStatusDisplayImageACBattery8.2.1.4 CommissioningStatusDisplaywhetherornotthemodulehassuccessfullybeencommissioned.Table8‐4CommissioningICONStatusDisplayImageCommissionedNot‐Commissioned8.2.1.5 InformationFigure8‐4ADXDASGeneralInformation Information:Displaystheserialnumber,latitude/longitude,firmwareversionofselectedmodule,andWebGUIversionoftheNMS. Location:DisplaystheaddresswheretheADXDASisinstalled. Description:Displaysthedescriptionofselectedmodule.ThedescriptionofeachmodulecanbeeditedfromtheInstalltab.Itisrecommendedtousethelocationofthemoduleasthedescription.Thisdescriptioninformationcanbeseenwhenhoveringoverthedevicetreeinordertoeasilyidentifyeachcomponent. TechnicalSupport:DisplaysADRF’sTechnicalSupportcontactinformation. InstallerContactInfo:Displaysthecontactinformationoftheinstaller.
AdvancedRFTechnologies,Inc.  688.2.2 StatusTab8.2.2.1 Status–NMSFigure8‐5Status‐NMSTheNMSStatuspageprovidesanoverallviewofhowthesystemisperforming.FromtheNMSStatuspage,theusercanseewhatmodulesareconnectedtoADXDAS.Inaddition,theusercanseeifanyalarmsarepresentinthesystemandalsothecommissioningstatusofeachmodule.8.2.2.1.1 SystemSummaryFigure8‐6SystemSummaryTheSummarysectionprovidestheuserwiththenumberofcomponentsphysicallyconnected,thenumberofsoft/hard/linkfailspresentinthesystem,andalsothenumberofcommissionedandnon‐commissionedcomponnets.
AdvancedRFTechnologies,Inc.  69Table8‐5SystemSummaryDescriptionParametersDescriptionConnectedDisplaythenumberofmodulesphysicallyconnectedtoADXDASSoftFailDisplaythenumberofsoftfailpresentoneachmoduleHardFailDisplaythenumberofhardfailpresentoneachmoduleLinkFailDisplaythenumberoflinkfailpresentoneachmoduleNotCommissionedDisplaythenumberofnon‐commissionedorcommissionfailedmoduleCommissionedDisplaythenumberofsuccessfullycommissionedmodule8.2.2.1.2 HEView/RUView,SystemScanTime HEView/RUView‐ DisplayswhethertheNMSissettoHEvieworRUview.‐ Refertosection3.1.1.4 SystemScanTime‐ Displaysthetimeittakestoscanandupdatetheinformationofallthemodulesthatareonthenavigationtree.Thistimewillincreaseasmorecomponentsareaddedtothesystem.‐ WhenNavigationTreeisunlocked,theusershouldwaitatleastthe“SystemScanTime”forthesystemtodetectnewlyaddedhardware.Figure8‐7Systemscantime,HEview/RUview8.2.2.1.3 HEAlarmStatusDisplaythealarmstatusofeachHEcomponent.Figure8‐8HEalarmstatus
AdvancedRFTechnologies,Inc.  708.2.2.1.4 HECommissioningStatusDisplaycommissioningstatusofeachHEcomponent.Figure8‐9HECommissioningstatusTable8‐6DescriptionforHECommissioningstatusStatusDisplayDescriptionInstalledStatusPhysicallyInstalledTextisblackPhysicallyNot‐InstalledTextisgrayCommissioningStatusSuccessGreenFailedornotcommissionedGray8.2.2.1.5 AlarmDisplaysalarmstatusoftheNMS.Ifanalarmispresentinthesystem,thecolorofthesystemalarmtabwillchangeaccordingtothetypeoffailure.Table8‐7DescriptionforNMSalarmAlarmSeverityDescriptionSystemOverTemperatureHardFail/SoftFailTemperatureofNMSishigherthanthethresholdlevelforovertemperaturealarmUnderTemperatureSoftFailTemperatureoftheNMSislowerthanthethresholdlevelforundertemperaturealarmSystemHaltHardFailHEsystemhaltPowerAlarmACFailSoftFailACpowerisoperatingoutsideofitsnormalrangeDCFailSoftFailDCpowerisoperatingoutsideofitsnormalrangeOverCurrentHardFailTotalcurrentofHEishigherthanthethresholdlevelforovercurrentalarmBatteryLowSoftFailVoltageofbatteryconnectedtoHEPSUislowerthanthedefinedthreshold
AdvancedRFTechnologies,Inc.  718.2.2.2 Status–BCUFigure8‐10Status–BCU8.2.2.2.1 BandDisplaysthebandwidthandthefrequencyrangesforDLandULoftheBCUmodule.Figure8‐11Status–BCUBand8.2.2.2.2 Power&AttenFigure8‐12Status–BCUPower&Atten
AdvancedRFTechnologies,Inc.  72 DLCommissioningLevel:DisplaysthecommissioninglevelforeachindividualRFpath.Ifunithasnotbeencommissioned,“NotCommissioned”willbedisplayed. DLInput:DisplaysthecurrentlyincomingsignalstrengthofeachRFpathalongwiththecompositeDLinputpowerofall3RFpaths. Atten:Displaystheattenuationvaluesthatthesystemiscurrentlyusingwhichisdefinedbythepowerratiosspecifiedbytheuser. DLOutput:DisplaystheoutputvalueforeachRFpathalongwiththecompositeDLoutputpowerofall3RFpaths.TheDLOutputlevelforeachRFpathwillnotexceed5dBmandthecompositeoutputpowerwillnotexceed10dBm.8.2.2.2.3 PowerRatioFigure8‐13Status–BCUPowerRatio TargetedDLOutputPower:Displaysdesiredpowerratiosspecifiedbytheuser.Ifunithasnotbeencommissioned,“NotCommissioned”willbedisplayed. ActualDLOutputPower:Displaysthecurrentlypowerratiosthatthesystemisusing.Thesevalueswillfluctuatebasedontheamountoftrafficthatisinthesystem.8.2.2.2.4 AlarmDisplaysthecurrentalarmstatusofeachindividualRFpath.ParametersforbothDLSignalLowandDLInputOverloadcanbespecifiedfromtheControltab.Figure8‐14Status–BCUAlarm
AdvancedRFTechnologies,Inc.  738.2.2.3 Status–RFUFigure8‐15Status–RFU8.2.2.3.1 BandDisplaysthebandwidthandthefrequencyrangesforDLandULoftheRFUmodule.Figure8‐16Status–RFUBand8.2.2.3.2 Power&Gain(Admin/User) AdminMode‐ DisplaystheDownlinkInput/output,Downlink/UplinkAttenuation,andUplinkOutput. UserMode‐DisplaystheDownlinkInput,Downlink/UplinkAttenuation,andUplinkOutput.Figure8‐17Power&GainDisplay(Admin)
AdvancedRFTechnologies,Inc.  74Figure8‐18Power&GainDisplay(User) Input[dBm]:DisplaystheDownlinkRFinputlevelwhichcomesfromtheADX‐H‐BCU,BTS.Thisvalueshouldbebetween0to25dBm. ALCAtten[dB]:TheamountofattenuationthatisbeingusedbythesystemwhenALCisactive. Atten[dB]:Theamountofattenuationthathasbeensetmanuallybytheuser. Output[dBm]:Thedownlink/uplinkoutputpoweroftheRFUandNOTtheoutputpoweroftheRU.8.2.2.3.3 AlarmDisplaysSystem,RF,andPowerAlarms.Ifanalarmispresentinthesystem,thenthecolorofthetabwillchangeaccordingtothetypeoffailure.Table8‐8RFUAlarmStatusAlarmSeverityDescriptionSystemLinkFailSoftFailAcomponentisphysicallyconnected,buttheNMSisunabletocommunicatewithit.OverTemperatureHardFail/SoftFailThetemperatureofNMSishigherthanthethresholdlevelforovertemperaturealarm.UnderTemperatureSoftFailThetemperatureofNMSislowerthanthethresholdlevelforundertemperaturealarm.SystemHaltHardFailSystemwillgointoa“SystemHalt”statewhenahardfailalarmdoesnotclearafter10checks.SystemHaltcanonlybeclearedwithapowercycle,reboot,orfactorysettings.RFAlarmDLSignalnotdetectedSoftFailDownlink inputsignal islowerthanthedefinedthresholdbyuser.DLSignalLowSoftFailDownlinkinputsignal islowerthanthedefinedthresholdbyuser.InputOverloadHardFail/SoftFailDownlinkinputsignal ishigherthanthedefinedthreshold.OverpowerHardFail/SoftFailUplinkoutputsignalishigherthanthedefinedthresholdbyuser.PowerAlarmACFailSoftFailACpowerisnotoperatingwithinparameters.DCFailSoftFailDCpowerisnotoperatingwithinparameters.OverCurrentHardFailTotalcurrentofHEishigherthanthethresholdlevelforovercurrentalarm.BatteryLowSoftFailVoltageofbatteryconnectedtoHEPSUislowerthanthedefinedthreshold.
AdvancedRFTechnologies,Inc.  758.2.2.4 Status–ODUFigure8‐19Status‐OPT8.2.2.4.1 SummaryTheSummarysectiondisplaysthenumberofremotemodulesthatarephysicallyconnected,thenumberofsoft/hard/linkfailalarms,andthenumberofRemoteModulethathavebeencommissionedandthenumberofRemoteModulethatneedtobecommissioned.Figure8‐20Summary(Status–OPT)
AdvancedRFTechnologies,Inc.  76Table8‐9SummaryDescriptionParametersDescriptionConnectedDisplaysthenumberofRemoteModule’sconnectedtotheADX‐H‐OPT.SoftFailDisplaysthetotalnumberofsoftfailpresent.HardFailDisplaysthenumberofhardfailpresentoneachmodule.LinkFailDisplaysthenumberoflinkfailpresentoneachmodule.NotCommissionedDisplaysthenumberofnon‐commissionedorcommissionfailedmodule.CommissionedDisplaythenumberofsuccessfullycommissionedmodule8.2.2.4.2 RFStatusDisplaystheDLinputpowerandtheULoutputpowerforeachODU.AnODURackiscomposedof2ODUs.Figure8‐21RFStatus(Status–OPT)8.2.2.4.3 OpticStatusDisplayLDPowerandPDPowerforeachopticpath.LDPoweristhepowerthatisbeingsenttotheRUandPDPoweristhepowerthatisbeingreceivedfromtheRU.Figure8‐22OpticStatus(Status–ODU)8.2.2.4.4 OpticAtten(AdminOnly)TheADX‐H‐ODUhas3typesofattenuators. DownlinkCommonAttenuator‐DisplaysthecommonattenuationlevelontheDLpath. UplinkCommonAttenuator‐DisplaysthecommonattenuationlevelontheULpath. UplinkOpticAttenuator‐Displaystheamountofattenuationusedateachopticallink.
AdvancedRFTechnologies,Inc.  77Figure8‐23OpticAttenuation(Status–OPT)8.2.2.4.5 OpticPathStatusDisplaystheopticstatusforeachopticpathFigure8‐24OpticPathStatus(Status–OPT)Table8‐10DescriptionforopticpathstatusStatusDisplayDescriptionLDStatusNormalGreen,opticsignalbeingsenttoMasterRUis>‐5dBmLDfailOrange,opticsignalbeingsenttoMasterRUis<‐5dBmNotConnectedGray,noconnectionbetweenODUandMasterRUPDStatusNormalGreen,opticsignalbeingreceivedfromMasterRUis>‐10dBmPDfailOrange,opticsignalbeingreceivedfromMasterRUis<‐10dBmCommFailorNotConnectedGray,noconnectionbetweenODU andMasterRUDownlinkCommonattenuatorUplinkCommonattenuatorUplinkOpticattenuator
AdvancedRFTechnologies,Inc.  788.2.2.5 Status–RUHubRU‐HubisnotseparatemodulebutisintegratedintothemasterRU.ThepictureofRUHubdisplayedonwebbasedGUIissameasthepictureofmasterRU.Figure8‐25Status‐RUHub8.2.2.5.1 RUAlarmStatusTheRUHubcansupportupto8remotemodules.TheRUalarmstatusdisplaysthealarmstatusofeachremotemodule.Figure8‐26RUAlarmStatus(Status‐RUHub)8.2.2.5.2 RUCommissioningStatusDisplaytheCommissioningstatusofeachRemoteModule.Figure8‐27RUCommissioningStatus(Status‐RUHub)
AdvancedRFTechnologies,Inc.  79Table8‐11DescriptionforRUCommissioningstatusStatusDisplayDescriptionInstalledStatusInstalledTextisblackNot‐InstalledTextisgrayCommissioningStatusSuccessGreenFailornotyetGray8.2.2.5.3 AlarmTable8‐12AlarmStatus(Status‐RUHub)AlarmSeverity DescriptionSystemLinkFailSoftFail PresentwhenamodulecannotcommunicatewiththeNMSSystemHaltHardFailSystemwillgointoa“SystemHalt”statewhenahardfailalarmdoesnotclearafter10checks.SystemHaltcanonlybeclearedwithapowercycle,reboot,orfactorysettings.PowerAlarmACFailSoftFail ACpowerisnotwithinparameters.DCFailSoftFail DCpowerisnotwithinparameters.OverCurrentHardFail TotalcurrentofRUishigherthanthethresholdlevelforovercurrentalarmBatteryLowSoftFail VoltageofbatteryconnectedtoRUPSUislowerthanthedefinedthreshold8.2.2.6 Status–RemotemoduleFigure8‐28Status–RemoteModule
AdvancedRFTechnologies,Inc.  808.2.2.6.1 BandDisplaythespectrumthatisbeingused.Thebandcolumndisplaysthebandwidththathasbeenused.Thedownlinkcolumndisplaysthecenterfrequencyoftheuseddownlinkband.Theuplinkcolumndisplaysthecenterfrequencyoftheuseduplinkband.Figure8‐29PCSBandInformation(Status–RemoteModule)8.2.2.6.2 Power&Gain(Admin/User)DisplaytheDownlinkoutput,Downlink/UplinkAttenuation,andUplinkInput/output.Figure8‐30Power&Gain(Admin)Figure8‐31Power&Gain(User) Admino Input[dBm]:DisplaystheRFinputlevelforUplinkonlyfortheRemoteModule.o ALCAtten[dB]:TheamountofattenuationusedwhenALCisactivate.o Atten[dB]:Theamountofattenuationmanuallysetbytheuser.o [M]Output[dBm]:OutputpowerofRFtransceiver(1ststageamplification).o [H]Output[dBm]:OutputpowerofdownlinkHPA(2ndstageamplification). Usero Input[dBm]:DisplaystheRFinputlevelforUplinkonlyfortheRemoteModule.o Atten[dB]:Theamountofattenuationmanuallysetbytheuser.o Output[dBm]:Displaysthetotalcompositeoutputpower.
AdvancedRFTechnologies,Inc.  818.2.2.6.3 OpticPower(Master‐RUOnly)DisplaytheLDPowerandPDPowerofopticmoduleinsidetheMasterRU.Figure8‐32OpticPower(Status–MasterRUonly)8.2.2.6.4 OperatingStatusTable8‐13OperatingStatus(Status–RemoteModule)AlarmSeverity DescriptionSystemLinkFailSoftFail NocommunicationwithNMS.OverTemperatureHardFail/SoftFailTemperature ishigherthanthethresholdlevelforovertemperaturealarm.UnderTemperatureSoftFail Temperatureislowerthanthethresholdlevelforundertemperaturealarm.SystemHaltHardFailSystemhaltoneithertheMasterRUorSlaveRU.Systemhaltoccurswhenahardfailalarmfailstoclearafter10checks.ORULDFailSoftFail LDFailpresentintheMasterRU’sopticunit.ORUPDFailSoftFail PDFailpresentintheMasterRU’sopticunit.RFAlarmInputOverloadHardFail Uplinkinputsignalishigherthanthedefinedthreshold.OverPowerHardFail/SoftFailDownlinkoutputsignalishigherthanthedefinedthresholdbyuser.VSWRSoftFail Triggeredwhenpowerisbeingreflectedbacktothesystem,typicallyduetoalooseconnector.PowerAlarmACFailSoftFail ACpowerisnotoperatingwithinparameters.DCFailSoftFail DCpowerisnotoperatingwithinparameters.OverCurrentHardFail TotalcurrentofRUishigherthanthethresholdlevelforovercurrentalarm.BatteryLowSoftFail VoltageofbatteryconnectedtoHEPSUislowerthanthedefinedthreshold.
AdvancedRFTechnologies,Inc.  828.2.3 ControlTab8.2.3.1 Control–NMSFigure8‐33Control‐NMS8.2.3.1.1 HeartbeatTimeAllowstheusertoenableordisableSNMPtrapsfrombeingsentoutandalsospecifytheHeartbeatinterval.Timeanddatestampsofthelast2heartbeatswillbedisplayedinthe“Lastheartbeatsentout”section.Figure8‐34Heartbeat(Control–NMS)8.2.3.1.2 HESystemAllowstheusertoperformaHEsystemrebootorHEfullsystemfactorysettingsFigure8‐35HESystemReboot&FactorySetting(Control–NMS)8.2.3.1.3 NMSSystemAllowstheusertoperformaNMSUnitrebootorNMSfactorysettingsFigure8‐36NMSSystemReboot&FactorySetting(Control–NMS)
AdvancedRFTechnologies,Inc.  838.2.3.2 Control–BCUFigure8‐37Control–BCU8.2.3.2.1 ManualATTControlFigure8‐38Control–BCUManualATTControl Downlink:AllowstheusertomanuallyadjusttheDLattenuationlevelsforeachRFpath.Adjustingthesesettingsisnotrecommendedsinceitwillchangethepowerratiossetbytheuser. Uplink:AllowstheusertomanuallyadjusttheULattenuationlevelsforeachRFpath.Adjustingthesesettingsisnotrecommended,unlessadditionalattenuationisneededontheULpath. DLOutputALCLevel:AllowstheusertomanuallysettheDLOutputALCLevelsforeachRFpath.Adjustingthesesettingsisnotrecommendedsinceitwillchangethepowerratiossetbytheuser.ThesesettingsareautomaticallysetbythesystemduringtheBCUcommissioningprocess.ThissectionalsodisplaysthecompositeDLOutputALCLevelwhichisthevaluethatcanbeusedtocommissiontheRFU.
AdvancedRFTechnologies,Inc.  848.2.3.2.2 Reboot/FactorySettingAllowstheuserrebootorrestorefactorysettingsoftheBCU.Figure8‐39Control–BCUReboot/FactorySetting8.2.3.2.3 AlarmSettingFigure8‐40Control–BCUAlarmSetting DownlinkInputOverload:AllowstheusertospecifythelevelatwhichtheDLInputOverloadalarmistriggered.Valuesrangefrom0dBmto+25dBm. DownlinkSignalLow:AllowstheusertospecifythelevelatwhichtheDLSignalLowalarmistriggered.Valuesrangefrom‐10dBmto+20dBm. DownlinkInputOverloadAlarmOn:AllowstousertoenableordisabletheInputOverloadAlarm [Path–A/B/C]DownlinkSignalLowAlarmOn:AllowstheusertoenableordisabletheDLSignalLowalarmforeachRFpath.8.2.3.3 Control–RFUFigure8‐41Control‐RFU
AdvancedRFTechnologies,Inc.  858.2.3.3.1 GeneralSettingToenableanyofthesettings,clickonthecheckboxandclicktheApplybutton.Figure8‐42GeneralSetting(Control–RFU)(Admin) Figure8‐43GeneralSetting(Control–RFU)(User)Table8‐14DescriptionforGeneralSettingNameDescriptionAvailableAccountsDownlinkALCEnablesordisablesDownlinkALCAdministratorUplinkALCEnablesordisablesUplinkALCAdministratorDownlinkONEnablesordisablestheRFUDownlinkpath Administrator,UserUplinkONEnablesordisables theRFUUplinkpathAdministrator,UserUplinkNoiseDetDisplaysifthemoduleisturnedonoroffduetotheULNoiseDetectionRoutineAdministrator8.2.3.3.2 Reboot/FactorySettingAllowstheuserrebootorrestorefactorysettingsoftheRFU.Figure8‐44Reboot&FactorySetting(Control–RFU)8.2.3.3.3 UplinkNoiseDetection(AdminOnly)Figure8‐45ULNoiseDetection(Control–RFU)
AdvancedRFTechnologies,Inc.  86The“ULNoiseDet”buttonwilltakeyoutotheULNoiseDetectionpagewhichwillallowyoutoruntheULNoiseDetectionroutine.Figure8‐46ULNoiseDetection‐PCSbandTheAutoULnoisemeasurementroutinecanberunbyclickingontheCheckbutton.AfterallULnoisemeasurementhavebeentaken,thelevelsforeachULpathwillbedisplayedandalongwiththedifferencebetweenminimumdetectlevelandmeasureddetectlevel.TheuserwillbeabletoseewhichpathisgeneratingtheelevatedULnoiselevelbasedonthemeasureddetectlevelanddifferencevalue.TonavigatebacktotheRFUcontrolpage,clickontheControltabagain.8.2.3.3.4 ManualAttenControl     (Admin)(User)Figure8‐47ManualAttenuatorControlSetting(Control–RFU)Table8‐15DescriptionforMainGainControlSetting(Control–RFU)NameDescriptionRangeStepAvailableAccountsDownlinkAttenDownlinkAttenuatortobeadjustedmanually 0~25dB 0.5dB Administrator,UserUplinkAttenUplinkAttenuatortobeadjustedmanually 0~35dB 0.5dB Administrator,UserDLOutputALCLevelTosettheMaxoutputALClevel‐10~0dBm 0.5dBm AdministratorULOutputALCLevelTosettheMaxoutputALClevel‐20~0dBm 0.5dBm Administrator,User
AdvancedRFTechnologies,Inc.  87DLOutputALCOffsetTosettheMaxoutputALCOffset‐10~0dBm 0.5dBm AdministratorULOutputALCOffsetTosettheMaxoutputALCOffset‐20~0dBm 0.5dBm Administrator8.2.3.3.5 AlarmSettingFigure8‐48AlarmThresholdSetting(Control–RFU)Table8‐16DescriptionforAlarmThresholdSetting(Control–RFU)NameDescriptionRangeDefaultthresholdDownlinkSignalLowAllowstheusertospecifytheminimumincomingDLinputsignallevelbeforetriggeringa“DownlinkSignalLow”soft‐failalarm.‐10~20dBm‐5dBmDownlinkSignalNotDetectedAllowstheusertospecifytheminimumincomingDLinputsignallevelbeforetriggeringa“DownlinkSignalNotDetected”soft‐failalarm.‐10~20dBm‐10dBmUplinkOverPowerAllowstheusertospecifythehowstrong theoutput signalofuplinkcanbebeforetriggeringan“UplinkOverPower”HardFailalarm.‐20~0dBm0dBm
AdvancedRFTechnologies,Inc.  888.2.3.4 Control–ODUFigure8‐49Control–OPT8.2.3.4.1 OpticAttenuation(AdminOnly)Figure8‐50OpticAttenuation–OPT
AdvancedRFTechnologies,Inc.  89Table8‐17DescriptionforOpticAttenuation(Control–OPT)NameDescriptionRangeDefaultthresholdDL/ULcommonATTAllowstheusertocontroloverallopticDL/ULpathgain. 0~30dB 5dBDLATTUsedtocompensateDLopticloss.0~13dB 13dBULATTUsedtocompensateULopticloss.0~13dB 13dB8.2.3.4.2 Reboot/FactorySettingAllowstheusertoperformODUrebootorODUfactorysettings.Figure8‐51Reboot&factorySetting(Control–OPT)8.2.3.5 Control–RHHubFigure8‐52Control–RUHub8.2.3.5.1 Reboot/FactorySettingAllowstheusertoperformRUHubrebootorRUHubfactorysettingsFigure8‐53Reboot&FactorySetting(Control–RUHub)
AdvancedRFTechnologies,Inc.  908.2.3.6 Control–RemoteModule(MasterorSlaveRU)Figure8‐54Control–RemoteModule8.2.3.6.1 GeneralSetting(Admin/User)   (Admin)(User)Figure8‐55GeneralSetting(Control‐RU)Table8‐18DescriptionforGeneralSetting(Control‐RU)NameDescriptionAvailableAccountsDownlinkALCThissettingallowsyoutoenableordisablethedownlinkALCfunction.WhenALCisenabled,thedownlinkoutputpowerwillnotexceedtheDownlinkOutputLevelspecifiedintheManualAttenControlsection.AdministratorDownlinkOnThissettingallowsyoutoenableordisabletheDownlinkpath. Administrator,UserUplinkALCThissettingallowsyoutoenableordisabletheuplink ALCfunction.WhenALCisenabled,theUplinkoutputpowerwillnotexceedtheUplinkOutputLevelspecifiedintheManualAttenControlsection.AdministratorUplinkOnThissettingallowsyoutoenableordisabletheUplinkpath. Administrator,User
AdvancedRFTechnologies,Inc.  918.2.3.6.2 Reboot/FactorySettingAllowstheusertoRebootorrestoreFactorySettingsontheremotemodule.Figure8‐56Reboot&factorySetting(Control‐RU)8.2.3.6.3 OpticSetting(OnlyMasterRU)(AdminOnly)Figure8‐57OpticSetting(Control‐RU)Table8‐19DescriptionforOpticSetting(Control‐RU)NameDescriptionRangeStepAvailableAccountsDownlinkOpticAttenRFattenuatortocompensatetheopticlossofdownlink0~13.0dB0.5dBAdministratorPDPowerIncomingpowerlevelfromtheODU   AdministratorLDPowerOutgoingpowerleveltotheODUAdministrator8.2.3.6.4 ManualAttenuatorControl(Admin)    (User)Figure8‐58ManualAttenControl(Control‐RU)
AdvancedRFTechnologies,Inc.  92Table8‐20DescriptionforManualAttenControl(Control‐RU)NameDescriptionRangeDefaultthresholdAvailableAccountsDownlinkAttenAllowstheusertospecifyhowmuchattenuationtouse.0~30dB30dBAdministrator,UserUplinkAttenAllowstheusertospecifyhowmuchattenuationtouse.0~25dB25dBAdministrator,UserDLOutputALCLevelTheremotemodulewillpreventthedownlinkoutputpowerfromexceedingthespecifiedvalue.5~30dB30dBmAdministrator,UserULOutputALCLevelThesystemwillpreventtheoutputpowertoexceedthespecifiedvalue.0~10dBm 5or6dBmAdministratorDLOutputALCOffsetWhentheincomingsignallevelincreases,thesystemwillnotadjustthegainlevelsuntilitreachestheALCOffsetLevel.0~10dB5dBAdministrator,UserULOutputALCOffsetWhentheincomingsignallevelincreases,thesystemwillnotadjustthegainlevelsuntilitreachestheALCOffsetLevel.0~10dB3dBAdministrator8.2.3.6.5 AlarmSettingFigure8‐59AlarmSetting(Control‐RU) DLOverPowerLimit:Theoverpoweralarmthresholdcanbeadjustedfrom5~30dBm.+2dBfromtheDLoverpowerlimitwilltriggerasoftfailand>2dBwilltriggerahardfailalarm VSWRAlarmON:EnableordisablestheVSWRAlarm.
AdvancedRFTechnologies,Inc.  938.2.4 InstallTab8.2.4.1 Install–NMSFigure8‐60Install‐NMS8.2.4.1.1 HECommissioningStatusFigure8‐61HECommissioningStatus(Install–NMS)Table8‐21DescriptionforHECommissioningStatus(Install–NMS)StatusDisplayDescriptionInstalledStatusPhysicallyInstalledTextisblackPhysicallyNot‐InstalledTextisgrayCommissioningStatusSuccessGreenFailornotcommissionedGray
AdvancedRFTechnologies,Inc.  948.2.4.1.2 SNMPFigure8‐62SNMP(Install–NMS)TheSNMPsectionallowsyoutospecifytheSiteIDandManagerIP.TheSite‐IDisthecodethatisusedtoidentifyaparticularmodule.TheManagerIPfieldiswheretheuserinputstheIPaddressoftheNOCsystemthatisbeingusedtomonitortheSNMPtraps.8.2.4.1.3 LocationThissectionallowstheusertoinputthelatitudeandthelongitudeoftherepeater.Figure8‐63LocationSetting(Install–NMS) SelectNorSfromthedropdownmenuforLatitude SelectEorWfromthedropdownmenuforLongitude Inputthefirst3numbersofthelatitude/longitudeinthetextareaafterthe“+”andbeforethe“.” Inputthelast6numbersofthelatitude/longitudeinthetextareaafterthe“.”8.2.4.1.4 ExternalModemBoxSettingsThissectionallowstheusertospecifyanalternativeIP,SubnetMask,andGatewaysettings.ThesesettingsareenabledwhentheHost/RemoteswitchissettotheRemoteposition.Figure8‐64ExternalModemBoxSetting(Install–NMS)8.2.4.1.5 Description
AdvancedRFTechnologies,Inc.  95ThissectionallowstheusertosavethedescriptionofNMS.Figure8‐65Description(Install–NMS)8.2.4.1.6 SNMPAgentFalseAlarmTestThissectionallowstheusertogeneratebothsoftandhardfailalarms.Afteralarmsaregenerated,theNOCcanpolltheADXtoseeifalarmsarepresent.Allalarmsgeneratedduringthistestarefalsealarms.Figure8‐66SNMPAgentFalseAlarmTest(Install–NMS)8.2.4.1.7 LocationInfo/InstallerInfoThissectionallowstheusertospecifytheaddressoftherepeaterandalsotheinformationoftheinstaller.Figure8‐67 LocationInfo/InstallerInfo(Install–NMS)
AdvancedRFTechnologies,Inc.  968.2.4.1.8 Date&TimeThissectionallowstheusertospecifythecurrentdateandtime.Figure8‐68Date&TimeSetting(Install–NMS)8.2.4.2 Install–RFUFigure8‐69Install‐RFU
AdvancedRFTechnologies,Inc.  978.2.4.2.1 RFUCommissioningThissectionallowstheusertoperformRFUcommission.ToperformRFUcommissioning,selectaDLInputCommissioningLevelfromthedropdownmenuandclickApply.ThecommissioningprogressisdisplayedontheCommissioningProgressbar.Anyerrors,warnings,andmessageswillappearviaapopupwindow.PleaserefertotheADXInstallationGuidetodeterminetheproperRFUcommissioninglevels.Figure8‐70RFUCommissioning(Install–RFU)8.2.4.2.2 DescriptionThissectionallowstheusertosetthedescriptionofRFU.Figure8‐71Description(Install–RFU)8.2.4.3 Install–OPTFigure8‐72Install–OPT8.2.4.3.1 OpticCommissioningThissectionwillallowtheusertoperformanyopticcompensationifitisnecessary.TheCommissioningbuttonwillturnorangeifopticcompensationisneeded.
AdvancedRFTechnologies,Inc.  98Figure8‐73Opticcontrol(Control–OPT)Table8‐22DescriptionforOpticcontrol(Control–OPT)Display&ControlDescriptionOpticlossislessthan5dBoOpticlossismorethan5dBoNotconnectedtoaRUNoopticlosscompensationisneeded.Opticlosscompensationisneeded.NotconnectedtoaRU8.2.4.3.2 DescriptionThissectionallowstheusertosavethedescriptionofOPT.Figure8‐74Description(Install–OPT)8.2.4.4 Install–RUHub
AdvancedRFTechnologies,Inc.  99Figure8‐75Install‐RUHub8.2.4.4.1 RUCommissioningStatusFigure8‐76RUCommissioningStatus(Install‐RUHub)Table8‐23DescriptionforRUCommissioningstatusStatusDisplayDescriptionInstalledStatusPhysicallyInstalledTextisblackPhysicallyNot‐InstalledTextisgrayCommissioningStatusSuccessGreenFailornotcommissionedGray8.2.4.4.2 DescriptionThissectionallowstheusertosavethedescriptionofRUHub.Figure8‐77Description(Install‐RUHub)8.2.4.5 Install–RemoteModule(MasterorSlaveRU)
AdvancedRFTechnologies,Inc.  100Figure8‐78Install‐RemoteModule8.2.4.5.1 RUOutputCommissioningThissectionallowstheusertoperformRUcommission.ToperformRUcommission,selectaDLOutputCommissioningLevelfromthedropdownmenuandthenclickApply.ThecommissioningprogressisdisplayedontheCommissioningProgressbar.Anyerrors,warnings,andmessageswillappearviaapopupwindow.Figure8‐79RUOutputCommissioning(Install‐RU)
AdvancedRFTechnologies,Inc.  1018.2.4.5.2 DescriptionThissectionallowstheusertosavethedescriptionofremotemodule.Figure8‐80Description(Install‐RemoteModule)8.2.5 SystemTheSystemtaballowstheusertoperformfirmwareupdates,uploadcloseoutpackages,viewanychangestothesystem,backupexistingconfiguration,andadd/removeuseraccounts,andchangethelogincredentialsoftheAdministrator.8.2.5.1 System:Account8.2.5.1.1 System:Account‐AccountManagement(AdminOnly)TheAccountManagementsectionallowstheAdministratortodeleteanyuser/guestaccount.PleasenotethattheAccountManagementsectionisonlyavailableifyouareloggedintothesystemastheAdministrator.Todeleteauser/guestaccountclickontheAccountManagementlinkandundertheDeletecolumn,clickonthedeletebutton.Figure8‐81AccountManagement8.2.5.1.2 System:Account‐NewAccount(AdminOnly)TheNewaccountsectionallowstheAdministratortocreateanewuser/guestaccount.PleasenotethatthenewaccountsectionisonlyavailableifyouareloggedintothesystemastheAdministrator.Tocreateanewuser/guestaccountclickonthenewaccountlinkandfillinthefieldshighlightedinyellowasshownbelow.Figure8‐82NewAccount
AdvancedRFTechnologies,Inc.  1028.2.5.1.3 System:Account‐ChangePasswordTheChangePasswordsectionallowsthecurrentuserwhoisloggedintothesystemtochangetheirlogincredentials.Figure8‐83ChangePassword8.2.5.2 System:Logs8.2.5.2.1 System:Logs‐EventLogThissectiondisplayssystemeventsthathavetakenplace.TheEventLogdisplayswhohasmadethechanges,thetimeanddateofwhentheeventtookplace,andwhatchangesweremadetothesystem.TheSystemLogtracksthefollowingevents: SystemInitiation AlarmSet AlarmClearFigure8‐84EventLog
AdvancedRFTechnologies,Inc.  1038.2.5.2.2 System:Logs‐UserLogThissectiontracksuseractivitywithinthesystem.TheUserLogdisplayswhohasmadethechanges,thetimeanddateofwhentheeventtookplace,andwhatchangesweremadetothesystem.TheUserLogtracksthefollowingitems: Login/Logoutactivity Changestogain/attenuation/outputvalues Systemeventgeneratedbyuser(firmwareupdate,backup/resote,create/deleteaccount) DASNavigationTreeLock/Unlock Descriptionchange Repeater/installerinformationchange Settingdate/timeFigure8‐85UserLog8.2.5.3 System:Update Toperformafirmwareupdate,clickontheSystem:Updatetabandthefollowingscreenwillshowup.Figure8‐86Systemupdate Clickonthe‘Browse’buttonandlocatethefirmwarefile. ClickontheUpdatebuttontoperformthefirmwareupdate.8.2.5.4 System:SystemInformation8.2.5.4.1 System:SystemInformation
AdvancedRFTechnologies,Inc.  104 SystemInformationCheckTheSystemInformationCheckbuttonwillchecktheADXconfiguationandreportpossiblediscrepancies. SystemInformationThissectiondisplaysthegeneralsysteminformationoftheADXDAS.Figure8‐87SystemInformation SystemNotificationThissectionisdisplayedonlywhenthefollowingconditionsarepresent:‐ WhenmultipleremotemoduleswithsamefrequencybandexistinaRU.‐ WhentheremotemoduledoesnotmatchwiththeRFUbeingused.Figure8‐88SystemNotification BOM
AdvancedRFTechnologies,Inc.  105BOMdisplaysallpartsthatareconnectedtotheADX‐H‐NMS.TheBOMcanbedownloadedasaCSVfilebyclickingthe‘Download’buttonatthebottomright.Figure8‐89Billofmaterial
AdvancedRFTechnologies,Inc.  1068.2.5.5 System:Backup/Restore SettingsBackupClickingtheBackupwillcreateatemporarybackupfilestoredinsideoftheADX.Oncethefileiscreated,itwillneedtobedownloadedtoacomputer.Adownloadbuttonwillappearafterthebackupfilehasbeencreated.IftheADXispowercycledorrebooted,thenthetemporarybackupfilewillbelost.Werecommenddownloadingthebackupfileimmediatelyafterithasbeencreated.ClickontheDownloadbuttontodownloadthebackupfile.Figure8‐90SettingBackup(Before)Figure8‐91SettingBackup(After)
AdvancedRFTechnologies,Inc.  107 SettingRestoreRestorefunctioncanbeusedtorestorethesavedsettingsfromthebackupfile.Oncethebackupfileisloaded,thetreeinthefigurebelowwillappear.Checktheboxesofthemodulesthatyouwouldliketorestoreandthenclickthe“Restore”buttonatthebottomonthissection.WerecommendcreatinganewbackupfileifaddingorremovingmodulesfromtheADX.Discrepanciesbetweenthebackupfileandtheexistingtreecouldcauserestoreerrors.Figure8‐92SettingRestore8.2.5.6 System:SNMP SNMPV1/V2ThissectionallowsyoutoaddcommunitystringsforSNMPv1andv2.Figure8‐93SNMPV1/V2
AdvancedRFTechnologies,Inc.  108 SNMPV3ThissectionallowstheusertoaddaccountsforSNMPv3.Figure8‐94SNMPV38.2.5.7 System:CloseoutPackageThecloseoutpackagesectionwillallowtheusertouploaddocumentstotheADX‐H‐NMS.Themaximumfilesizeforeachuploadislimitedto10MB.Thetotalamountofspaceavailableforuploadingdocumentis100MB.Pleasedonotusethissectionastheprimarystoragelocationofyourdocuments.Documentsmaybecomeunavailableifthesystemgoesdown.Figure8‐95System‐CloseoutPackageTouploaddocumentstothemodule,clickonthe“Browse”buttonandlocatethefilethatyouwouldliketoupload,thenenterinaDescriptionofthefilebeinguploaded.Afterwards,clickonthe“AddFile”buttontouploadthefile.Belowiswhatyouwillseeafterthefileupload.Todeletethefile,clickonthedeletebuttonlocatedinthelastcolumn.Figure8‐96System‐CloseoutPackageafterthefileupload
AdvancedRFTechnologies,Inc.  1098.2.6 HelpIfaninternetconnectionisavailable,clickingontheHelpTabwillredirecttheusertoourTechnicalSupportpage.Figure8‐97Help8.2.7 LogoutClickingtheLogoutbuttonwilllogthecurrentuseroffthesystem.8.3 GuestModeWhenloggingintothesystemasaguest,theguestwillonlyhaveread‐onlyprivilegesandwillnotbeabletomakeanychangestothesystem.
AdvancedRFTechnologies,Inc.  1109. SYSTEMSPECIFICATION9.1 SpecificationforPS78,SMRParametersPS78SMRFrequencyDownlinkP7758‐775MHzS8851‐869MHzS9929‐930MHz935‐940MHzUplinkP7788‐805MHzS8806‐824MHzS9896‐901MHzInputPowerRange0~+25dBmGainDownlink5~30dB,0.5dBstep,ATTrange:0~25dBUplink‐5~30dB,0.5dBstep,ATTrange:0~35dBMaximumOutputPower1DownlinkatRU30dBm±2dBUplinkatHE‐15dBm±2dBNoiseFigure<10dB@maximumgainVSWR<1:1.5OpticalLoss0~5dBoSystemDelay<2usSpuriousMeetFCCrules,3GPPTS36.104,3GPP2C.S0010‐CNominalBand/BWforIndustryCanadaDownlinkP7749‐781MHzS8840‐880MHzS9925‐949MHzUplinkP7782‐831MHzS8811‐834MHzS9887‐911MHzDimension(WXDXH)Head‐EndShelf19.0x14.6x12.2inches(482x370x311mm)Remote‐UnitShelf19.0x12.9x10.5inches(482x328.2x266.5mm)MasterRU11.8x9.8x4.5inches(300x249.6x114.5mm)SlaveRU11.8x9.8x3.7inches(300x249.6x94.5mm)WeightHead‐EndShelf83.7lbs(38.0Kg)@4RFU,CHC‐H,PSUandNMSRemote‐UnitShelf61.0lbs(27.7kg)@1masterRU,3SlaveRUMasterRU13.2lbs(6.0kg)SlaveRU11.7lbs(5.3kg)OperatingTemperature14‐122F(‐10‐50°C)OperatingHumidity5~90%RHPowerInput110/220V,50‐60Hz,24Vor‐48VDC(optional)PowerHead‐End52W@4RFU,1ODURackwith2ODUsandNMS1TheManufacturer'sratedoutputpowerofthisequipmentisforsinglecarrieroperation.Forsituationswhenmultiplecarriersignalsarepresent,theratingwouldhavetobereducedby3.5dB,especiallywheretheoutputsignalisre‐radiatedandcancauseinterferencetoadjacentbandusers.Thispowerreductionistobebymeansofinputpowerorgainreductionandnotbyanattenuatorattheoutputofthedevice메모 [H5]: 주파수범위수정15/05/19메모 [Y6]: 실제로측정하셔서기입요청합니다.15/02/03
AdvancedRFTechnologies,Inc.  111consumption28W@1RFU,,1ODURackwith2ODUsandNMSRemote‐Unit60W53WNetworkManagementSystemEthernet(RJ45)RFconnectorHead‐EndN‐type(Female)Remote‐UnitN‐type(Female)Input/outputImpedance509.2 SpecificationforVU,BTParametersBTTBDFrequencyDownlink2496‐2690MHz(BRSTDD)Uplink2496‐2690MHz(BRSTDD)InputPowerRange‐15~+37dBmGainDownlink0~52dB,0.5dBstep,ATTrange:0~52dBUplink‐5~30dB,0.5dBstep,ATTrange:0~35dBMaximumOutputPower2DownlinkatRU37dBm±2dBUplinkatHE‐15dBm±2dBNoiseFigure<10dB@maximumgainVSWR<1:1.5OpticalLoss0~5dBoSystemDelay<2usSpuriousMeetFCCrules,3GPPTS36.104,3GPP2C.S0010‐CDimension(WXDXH)MasterRU11.8x9.8x4.5inches(300x249.6x114.5mm)SlaveRU11.8x9.8x3.7inches(300x249.6x94.5mm)WeightMasterRU13.2lbs(6.0kg)SlaveRU11.7lbs(5.3kg)OperatingTemperature14‐122F(‐10‐50°C)OperatingHumidity5~90%RHPowerInput110/220V,50‐60Hz,24Vor‐48VDC(optional)PowerconsumptionHead‐End52W@4RFU,1ODURackwith2ODUsandNMS28W@1RFU,1ODURackwith2ODUsandNMSRemote‐Unit87WNetworkManagementSystemEthernet(RJ45)RFHead‐EndN‐type(Female)2TheManufacturer'sratedoutputpowerofthisequipmentisforsinglecarrieroperation.Forsituationswhenmultiplecarriersignalsarepresent,theratingwouldhavetobereducedby3.5dB,especiallywheretheoutputsignalisre‐radiatedandcancauseinterferencetoadjacentbandusers.Thispowerreductionistobebymeansofinputpowerorgainreductionandnotbyanattenuatorattheoutputofthedevice
AdvancedRFTechnologies,Inc.  112connectorRemote‐UnitN‐type(Female)Input/outputImpedance509.3 FCCCertificationItemFCCCertificationADX‐R‐SMRPart20,Part90ADX‐R‐78PPart90ADX‐R‐BTPart2010. ANTENNASPECIFICATIONS10.1 OmniAntennaFrequency698‐960MHz1710‐2690MHzPolarizationVerticalGain2dBi3dBiVSWR<1.7:1<1.5:1Impedance50PowerRating50WNote.Pleasenotethatintegrators,end‐usersorinstallersshouldnotusetheantennawithmoregainthan3dBi(ForModel:ADX‐R‐BT),2dBi(ForModel:ADX‐R‐SMR,ADX‐R‐78P)tomeettheRFexposurerequirement.Part90.635requirementAntennasmustbeinstalledinaccordancewithFCC90.635.With2dBigainantennastheheightoftheantennaaboveaverageterrain(HAAT)ispermittedover1372m.Fordifferentgainantennasrefertotherelevantrules.Part90.219requirementTheradiatedpowermustbelimitedto1W.Therefore,thisdevicemeetthe90.219(e)(1)5WERPlimitationrequirement.PriortoequipmentusetheservicemustberegisteredwiththeFCC.ThiscanbedonethroughtheFCC’swebsiteathttps://signalboosters.fcc.gov/signal‐boosters메모 [Y7]: FCCpart 명기15/02/03메모 [Y8]: 안테나규격추가15/02/03
AdvancedRFTechnologies,Inc.  11311. MECHANICALDRAWINGFigure11‐1HEDrawing
AdvancedRFTechnologies,Inc.  114Figure11‐2RFUDrawingforSMR/PS
AdvancedRFTechnologies,Inc.  115Figure11‐3RFUDrawingforVU
AdvancedRFTechnologies,Inc.  116Figure11‐4RFUDrawingforBTFigure11‐5MasterRUDrawingforPS
AdvancedRFTechnologies,Inc.  117Figure11‐6MasterRUDrawingforBT
AdvancedRFTechnologies,Inc.  118Figure11‐7SlaveRUDrawingforSMR
AdvancedRFTechnologies,Inc.  119Figure11‐8SlaveRUDrawingforVU
AdvancedRFTechnologies,Inc.  120Figure11‐9RURackShelfDrawing