ADC Telecommunications PSM7A7UD FlexWave Prism HDM 700 Lower ABC/Upper C User Manual RF modules installation guide

ADC Telecommunications Inc FlexWave Prism HDM 700 Lower ABC/Upper C RF modules installation guide

RF modules installation guide

TECP-77-141  Issue 5  November 2013300001744178 Rev EDual-Band Dual-Slot RF ModuleSingle-Slot RF ModuleDual-Slot 40W RF Module HDM RF ModuleFlexWave Prism®RF Modules for Prism Remote UnitsInstallation Guide
Copyright© 2013 TE Connectivity, Inc. All Rights Reserved.Information contained in this document is company private to TE Connectivity Ltd., and shall not be modified, used, copied, reproduced or disclosed in whole or in part without the written consent of TE.Trademark InformationFlexWave, FlexWave Prism, InterReach Spectrum, InterReach Unison, Universal Radio Head, TE Connectivity, and TE connectivity (logo) are trademarks.All other logos, products and/or company names referred to herein might be trademarks of their respective owners. Disclaimer of LiabilityContents herein are current as of the date of publication. TE reserves the right to change the contents without prior notice. Should the content of printed user documentation shipped with product differ from documentation provided on a product CD (inclusive of the associated Help modules), the printed user documentation supersedes the documentation on the product CD. In no event shall TE be liable for any damages resulting from loss of data, loss of use, or loss of profits, and TE further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of liability applies to all products, publications and services during and after the warranty period.Specific Disclaimer for High-Risk ActivitiesThis Product is not specifically designed, manufactured, tested or intended for use in high-risk activities including, without restricting the generality of the foregoing, on-line control of aircraft, air traffic, aircraft navigation or aircraft communications; or in the design, construction, operation or maintenance of any nuclear facility. TE (including its affiliates) and its suppliers specifically disclaim any express or implied warranty of fitness for such purposes or any other purposes.
FlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 1TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013 ©2013 TE Connectivity Ltd.TABLEOFCONTENTSPreface .................................................................................................................................................................2RevisionHistory...................................................................................................................................................... 2FlexWavePrismUserDocumentation.................................................................................................................... 3DocumentCautionsandNotes .............................................................................................................................. 3AccessingUserDocumentationontheTECustomerPortal .................................................................................. 4StandardsCertification........................................................................................................................................... 5OverviewofRFModulesforPRUs ........................................................................................................................6PRURFModuleTypes ............................................................................................................................................ 7PrismRemoteUnitSingle‐andDual‐CardRFModules ......................................................................................................8PrismRemoteUnitHDMRFModules ................................................................................................................................9PrismRemoteUnitDual‐Slot40WRFModules................................................................................................................10SupportedRFModules......................................................................................................................................... 10RFModuleComponents .....................................................................................................................................12DuplexerandLowNoiseAmplifier.......................................................................................................................13LinearPowerAmplifiers ....................................................................................................................................... 13DigitalProcessingModule.................................................................................................................................... 14UnderstandingtheRFModuleCables .................................................................................................................15PowerCableConnection ...................................................................................................................................... 15LVDSCableConnections....................................................................................................................................... 15RFCableConnections........................................................................................................................................... 15RFCableRules ..................................................................................................................................................................16RFModuleCablesforSingle‐Card,Dual‐Card,andHDMRFModules .............................................................................16RFModuleCablesforDual‐SlotInstallations ...................................................................................................................17RFGroupAssignmentsforPRUs........................................................................................................................... 18InstalltheRFModule(s)......................................................................................................................................21SafetyPrecautions................................................................................................................................................ 21GuardagainstDamagefromElectro‐StaticDischarge ......................................................................................... 22UnpackandInspecttheRFModule ..................................................................................................................... 22RemoveReleaseLinersfromtheRFModule ....................................................................................................... 23Dual‐SlotModulesOnly—RemovetheModuleSlotShelf ................................................................................... 25InstalltheRFModuleintothePrismRemoteChassis.......................................................................................... 26SecureRFModuleLatches ................................................................................................................................... 34ConnectLatchesonSingle‐SlotandHDMRFModules ....................................................................................................35ConnectLatchesonDual‐BayDual‐SlotRFModules........................................................................................................36LatchesonDual‐Slot40WRFModules.............................................................................................................................37VerifythattheRFModuleMountingHookisEngaged ....................................................................................................37ConnecttheRFModuleCables ............................................................................................................................ 37ConnectingCablesinaSingle‐SlotRFModuleInstallation ..............................................................................................38ConnectingCablesinaDual‐SlotRFModuleInstallation.................................................................................................40PowerontheRFModule...................................................................................................................................... 45ContactingTEConnectivity .................................................................................................................................46ContactingTEConnectivitybyTelephone............................................................................................................ 46ContactingTEConnectivityOnline ....................................................................................................................... 46
Preface  Page 2 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2013 TE Connectivity Ltd TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013PREFACEThismanualprovidestheinformationyouneedtoinstallTEConnectivityFlexWavePrism®RFModulesintoaPrismRemoteUnit(PRU).InstallationinstructionsareprovidedforthefollowingPrismRemoteUnitRFModules:•Single‐SlotRFModules,whichincludestheHDMRFModules•Dual‐SlotRFModules–Dual‐CardRFModules–40WRFModules.NOTE: ThisinstallationguidedocumentstheRFModulesthatarecompatiblewiththeFlexWavePrismRemoteUnit,whichisdesignedforoutdooruse.ForinformationontheRFModulesdesignedforusewiththeFlexWavePrismIndoorRemoteUnits(IRUs),seetheFlexWavePrismIndoorRemoteUnitInstallationGuide(TECP‐77‐197).RevisionHistoryTable 1. Revision HistoryIssue Document Date Technical Updates1April 2012 Original2February 2013 Changed Prism remote Unit model names from Single-/Dual-/Tri-/Quad-Band to Single-/Dual-/Tri-/Quad-Bay; updated Table 4 on page 10 to add new RF Modules; removed the Specifications section, which included the RF and Optical Specifications and the Frequency and Composite Output Power at Antenna Port (dBm) for Prism Remote Units tables; to access these performance specifications, refer to the FlexWave Prism Performance Specifications (TECP-77-201); updated “Contacting TE Connectivity” on page 46.3May 2013 Updated “Accessing User Documentation on the TE Customer Portal” on page 4; added “Understanding the RF Module Cables” on page 15; updated “Connect the RF Module Cables” on page 37.4October 2013 Added support for the following HDM RF Modules, in conjunction with Prism EMS Software Release 8.1.1: HDM AWS Band 4 MIMO 20W; HDM AWS Band 4 SISO 40W; HDM PCS Band 25 SISO 40W (see Table 4 on page 10); updated Table 2 on page 3.5November 2013 Adds support for the
FlexWave Prism User DocumentationFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 3TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013 © 2013 TE Connectivity Ltd.FlexWavePrismUserDocumentationFlexWavePrismuserdocumentationisintendedforsystemadministrators,engineersandinstallersresponsibleforplanning,administering,configuring,andmaintainingFlexWavePrismsystems.Table2liststhemanualsthatcorrespondtothefeaturesoftheFlexWavePrismEMSdescribedinthisguide.DocumentCautionsandNotesTwotypesofmessages,identifiedbelow,appearinthetext:CAUTION! Cautionsindicateoperationsorstepsthatcouldcausepersonalinjury,induceasafetyprobleminamanageddevice,destroyorcorruptinformation,orinterruptorstopservices.NOTE: Notescontaininformationaboutspecialcircumstances.Table2.FlexWavePrismUserDocumentationTitle Catalog Number FlexWavePrismSoftwareRelease8.1SystemSetupandProvisioningGuide(1) TECP-77-214FlexWavePrismSoftwareRelease8.1.1PerformanceSpecifications(2) TECP-77-229HostUnitIIInstallationGuide TECP-77-206HostUnitExpansionUnitInstallationGuide TECP-77-202HostUnitIIandHostUnitExpansionUnitModuleReplacementGuide TECP-77-207PrismRemoteUnitInstallationGuide TECP-77-142RFModulesforPrismRemoteUnitsInstallationGuide(3) TECP-77-141IndoorRemoteUnitInstallationGuide TECP-77-197OADMSpliceBoxInstallationGuide TECP-77-208CoarseWavelengthDivisionMultiplexerUserGuide TECP-77-2091 Release 8.1 is the earliest release of the FlexWave Prism EMS that supports the hardware features described in this installation guide.2 Release 8.1.1 is the earliest release of the FlexWave Prism EMS that supports the RF Modules added to this installation guide; see “Revision History” on page 2.3 The Prism Remote RF Modules and Remote Mounting Kit are designed for use only in the Prism Remote Unit (PRU). The IRU RF Modules and mounting options are described in the FlexWave Prism Indoor Remote Unit Installation Guide (TECP-77-197).
Preface  Page 4 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2013 TE Connectivity Ltd TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013AccessingUserDocumentationontheTECustomerPortal1ClickonthefollowingURLlink:https://www.te.com/portal/wireless/ (Alternatively,entertheprecedingURLintoyourwebbrowser,andthenpressENTERonyourkeyboard.)2AccesstotheCustomerPortalrequiresauseraccountandpassword.OntheSign Inpage,dooneofthefollowing:3OntheWirelessCustomerPortalhomepageintheKnowledge Centerpanel,clicktheManualsandDataSheetslink.4OntheManualsandDataSheetspage,dothefollowing:aIntheDocument Repositorypanel,scrolltothesectionfortheproductlineofthedocumentthatyouwanttoaccess.bClickonthetitleofthemanualthatyouwishtoopen.c(Optional)SavethePDFtoyourPCorlaptop.If you have anaccount, enteryour Email andPassword and click Sign In.If you don’t have anaccount, click Register Now and follow the prompts.
Standards CertificationFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 5TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013 © 2013 TE Connectivity Ltd.StandardsCertificationFCC:ThisequipmentcomplieswiththeapplicablesectionsofTitle47CFRPart15(HostUnit),Part22(800MHzCellular),Part24(1900MHz‐PCS),Part90(800/900‐SMR),andPart27(2100MHz‐AWS)&(700MHz‐LTE).IC:ThisequipmentcomplieswiththeapplicablesectionsofRSS‐131.Theterm“IC:”beforetheradiocertificationnumberonlysignifiesthatIndustryCanadaTechnicalSpecificationsweremet.TheManufacturer'sratedoutputpowerofthisequipmentisforsinglecarrieroperation.Forsituationswhenmultiplecarriersignalsarepresent,theratingwouldhavetobereducedby3.5dB,especiallywheretheoutputsignalisre‐radiatedandcancauseinterferencetoadjacentbandusers.Thispowerreductionistobebymeansofinputpowerorgainreductionandnotbyanattenuatorattheoutputofthedevice.Note:TocomplywithMaximumPermissibleExposure(MPE)requirements,themaximumcompositeoutputfromtheantennacannotexceed1000WattsERP(LTE,CellularandSMR),theantennacannotexceed1640WattsEIRP(PCSandAWS),andtheantennamustbepermanentlyinstalledinafixedlocationthatprovidesatleast6meters(20feet)ofseparationfromallpersons.UL/CUL:Thiswillbeinstalledinarestrictedaccesslocation.ThisequipmentcomplieswithType4,perULandCUL50,StandardforEnclosuresforElectricalEquipment.ThisequipmentprovidesthedegreeofprotectionspecifiedbyIP66asdefinedinIECPublication529.FDA/CDRH:ThisequipmentusesaClass1LASERaccordingtoFDA/CDRHRules.Thisproductconformstoallapplicablestandardsof21CFRPart1040.Caution:Modificationsnotexpresslyapprovedbythepartyresponsibleforcompliancecouldvoidtheuser'sauthoritytooperatetheequipment.EUHarmonizedStandards:MeetsessentialrequirementsofR&TTE1999/5/EC.•Article3.1a—Theprotectionofthehealthandthesafetyoftheuserandanyotherperson,includingtheobjectiveswithrespecttosafetyrequirementscontainedinDirective2006/95/EC,butwithnovoltagelimitapplying.•Article3.1b—TheprotectionrequirementswithrespecttoelectromagneticcompatibilitycontainedinDirective2004/108/EC.•Article3.2—Inaddition,radioequipmentshallbesoconstructedthatiteffectivelyusesthespectrumallocatedtoterrestrial/spaceradiocommunicationandorbitalresourcessoastoavoidharmfulinterference.EMCStandards:EN55022andEN55024(CEmarked)SafetyStandards:ThisequipmentcomplieswithIEC60950‐1,2NDEdition+Amendment1(CEmarked)andwithUL60950‐1,2NDEdition+Amendment1(FilenumberE174166)(USAandCanada)
Overview of RF Modules for PRUs  Page 6 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2013 TE Connectivity Ltd TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013OVERVIEWOFRFMODULESFORPRUSFigure1illustratesthePrismRemoteUnit(PRU),whichcontrolsRFemissions,interfaceswiththeFlexWaveHost.Figure1.Prism Remote UnitsThePRUhasfromonetofourRFModuleslots,dependingonthePRUmodel.Thatis,theSingle‐BayPRUhasoneRFModuleslot,andtheQuad‐BayPRUhasfourRFModuleslots.APRUcansupportuptofourRFModules.ThefunctionofthePRURFModulesontheForwardPathisto:•convertthedigitizedRFtransportedfromtheHosttoAnalogRF•amplifytheAnalogRFsignal•providesignalfiltering.ThefunctionofthePRURFModulesontheReversePathisto:•converttheAnalogRFfromthehandsettoDigitalRFfortransporttotheHost•providesignalfiltering.Single-BayPrism Remote UnitDual-BayPrism Remote UnitTri-BayPrism Remote UnitQuad-BayPrism Remote Unit
PRU RF Module TypesFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 7TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013 © 2013 TE Connectivity Ltd.EachRFModulecansupportanyofthefollowingDARTcombinations:•oneClassicDARToroneSingleSuperDART•twoClassicDARTs•twoSingleSuperDARTs•oneDualSuperDART•oneortwosetsofTxorRxBoards(HDM)–HDM‐850hasoneset–HDM‐700hastwosets.EachRFModulewillhaveuptotwo6‐timeslotDARTsorone12‐timeslotDARTsperRFModule.TheRFModulesarefieldreplaceable,butcannotbeservicedinthefield.PRURFModuleTypesThePRURFModulesareavailableinthefollowingformats,andasdescribedinthefollowingsections:•“PrismRemoteUnitSingle‐andDual‐CardRFModules”onpage8•“PrismRemoteUnitHDMRFModules”onpage9•“PrismRemoteUnitDual‐Slot40WRFModules”onpage10.
Overview of RF Modules for PRUs  Page 8 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2013 TE Connectivity Ltd TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013PrismRemoteUnitSingle‐andDual‐CardRFModulesFigure2showsexamplesofPRUSingle‐andDual‐SlotRFModules,bothofwhichhavetwoDARTs.APRUSingle‐andDual‐CardRFModulecomprise:•oneDART•oneDuplexerwithoneortwointernalLowNoiseAmplifiers(LNAs)•oneLinearPowerAmplifier(LPA)•oneRemoteDARTInterface(RDI)board.Figure2.Single- and Dual-Slot RF ModulesDual-Band Dual-Slot RF ModuleSingle-Slot Dual-Card RF Module
PRU RF Module TypesFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 9TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013 © 2013 TE Connectivity Ltd.PrismRemoteUnitHDMRFModulesPRUHDMRFModules(Figure3)aredesignedfor850Cellfrequencies.TheinitialreleaseoftheHDMRFModuleisaSingleInputSingleOutput(SISO)Configurationthat•interfacesoneHostDART—eitherClassicorSuperDART•supportstwonon‐contiguousRFslicesupto25MHztotalbandwidth—SuperDARTonly•supportsupto40WRFoutputpower.Figure3.HDM RF ModuleThecomponentsofaPRUHDMRFModulearedependentonthemoduletype,aslistedinTable3.Table3.ComponentsofPRUHDMRFModulesRF Module Type DPM LPA Duplexer Rx Card Tx CardSISO (1)  1 1 1 1 1MIMO/Dual Band Module (2)1 2 2 2 2(1) 850 20W and 40W only.(2) 700 MIMO 20W and 850/1900 20W only.
Overview of RF Modules for PRUs  Page 10 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2013 TE Connectivity Ltd TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013PrismRemoteUnitDual‐Slot40WRFModulesTheFlexWavePRUDual‐Slot40WRFModule(Figure5)isdesignedforAWSandPCSfrequencies.ThePrismRemote40WRFModulecomprises:•oneDART•twoPowerAmplifiers(PAs)•oneRemoteDARTInterface(RDI)board.NOTE: ThismanualdescribeshowtoinstallthePCS1900andAWS2100Non‐DiversityRFModules.Figure4.Dual-Slot 40W RF ModuleSupportedRFModulesTable4.FlexWavePrismRFModulesforPRUsSupportedinthisInstallationGuideCatalog Number DescriptionFWP-4210000MOD 6.5W 800 SMR MODULE, NON-DIVERSITY, CLASSIC FWP-6216000MOD 10W, EGSM 900, NON-DIVERSITY, SGL SD FWP-6226000MOD 10W, EGSM 900, DIVERSITY, SGL SD FWP-7416000MOD 20W, GSM 1800, NON-DIVERSITY, SGL SD FWP-741S000MOD 20W, GSM 1800, NON-DIVERSITY, DL SD FWP-7426000MOD 20W, GSM 1800, DIVERSITY, SGL SD
Supported RF ModulesFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 11TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013 © 2013 TE Connectivity Ltd.FWP-8410000MOD 20W RF Module, PCS 1900 Non-Diversity EnclosureFWP-8416000MOD 20W PCS MODULE, NON-DIVERSITY, SGL SD FWP-841S000MOD  20W RF Module, PCS 1900 12S EnclosureFWP-8420000MOD 20W RF Module, PCS 1900 Diversity EnclosureFWP-8426000MOD 20W PCS MODULE, DIVERSITY, SGL SD FWP-84MT000MOD 20W RF MOD, PCS1900, MIMOFWP-8810000MOD 40W PCS MODULE, NON-DIVERSITY, CLASSIC (DUAL-SLOT) FWP-881T000MOD HDM PCS Band 25 SISO 40WFWP-9416000MOD 20W, UMTS 2100, NON-DIVERSITY, SGL SD FWP-9416D00MOD 20W 2100 UMTS MODULE, DIV Ready, SGL SD FWP-941S000MOD 20W, UMTS 2100, NON-DIVERSITY, DL SD FWP-9426000MOD 20W, UMTS 2100, DIVERSITY, SGL SD FWP-A410000MOD 20W RF Module, AWS 2100 Non-Diversity EnclosureFWP-A416000MOD 20W AWS MODULE, NON-DIVERSITY, SGL SD FWP-A41S000MOD  20W RF Module, AWS 2100 12S EnclosureFWP-A420000MOD 20W RF Module, AWS 2100 Diversity EnclosureFWP-A426000MOD 20W AWS MODULE, DIVERSITY, SGL SD FWP-A4MT000MOD HDM AWS Band 4 MIMO 20WFWP-A810000MOD 40W AWS MODULE, NON-DIVERSITY, CLASSIC FWP-A81T000MOD HDM AWS Band 4 SISO 40WFWP-B410000MOD 20W WIDEBAND CELL MODULE, NON-DIVERSITY, Classic FWP-B420000MOD 20W WIDEBAND CELL MODULE, DIVERSITY, CLASSIC FWP-B810100MOD 40W WIDEBAND CELL MODULE, NON-DIVERSITY, (SGL-SLOT) FWP-C4MT000MOD DUAL 20W 850/1900 RF MODULE, (SGL BAY)FWP-D210000MOD 6.5W 800/900 ESMR MODULE, NON-DIVERSITY, CLASSIC FWP-F216000MOD 10W APAC EGSM (885-915) MODULE, SGL SD FWP-I210000MOD 6.5W APAC iDEN Module, Non-Diversity, Classic (Extended 1 MHz) FWP-K216000MOD 10W 900 P-GSM Module, Non-Diversity, SGL SD FWP-K226000MOD 10W 900 P-GSM Module, Diversity, SGL SD FWP-L416000MOD 20W 700 Lower ABC MODULE, NON-DIVERSITY, SGL SDFWP-L4MT000MOD DUAL 20W 700 LOWER ABC MODULE, MIMOFWP-L4MTU4MMOD 20W RF MOD, 700ABC/700UCFWP-U416000MOD 700 LTE, UPPER C, 20W MODULE, SISO, SGL SDFWP-U4MT000MOD DUAL 20W 700 UPPER C MODULE, MIMOFWP-U816100MOD 40W 700 Upper C MODULE, NON-DIVERSITY, SGL SD (SGL-SLOT)Table4.FlexWavePrismRFModulesforPRUsSupportedinthisInstallationGuide(Cont.)Catalog Number Description
RF Module Components  Page 12 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2013 TE Connectivity Ltd TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013RFMODULECOMPONENTSFigure5showstypicalRFModulecomponents,usingtheSingle‐SlotRFModuleasanexample.Figure5.PRU Single-Slot RF Module ComponentsFigure6showsthecomponentsofanHDMRFModule.Figure6.HDM RF Module ComponentsMountinglatchMounting hookDuplexer Power Amplifier (PA)DARTsDuplexers Power AmplifierMounting latchMounting hookTx and Rx Cards
Duplexer and Low Noise AmplifierFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 13TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013 © 2013 TE Connectivity Ltd.DuplexerandLowNoiseAmplifierTheRFModuleprovidesthePRUwithaninternalDuplexerthatisoptimizedtoprovidethedesiredRFband‐passfilteringandin‐bandequipmentisolationbetweenFWDandREVpaths.TheDuplexerprovidesthefilteringnecessarytothetransmitandreceivepathstoandfromtheconnectedantenna.TheDuplexerforthePrismRemoteUnitSingle‐andDual‐CardRFModulesandtheDual‐Slot40WRFModulescontainsuptotwoREVpathLowNoiseAmplifiers(LNAforPRIand/orSECreversepaths).EachLNAprovidesthePrismreversepathwithnominal30dBREVgainandsystemNFof5dBperRXpath.TheDuplexerforanHDMRFModuledoesnothaveaLowNoiseAmplifier.Duplexersarenotfieldserviceable.LinearPowerAmplifiersTheLinearPowerAmplifier(LPA)isahighqualitybroadbandRFamplifierusedforachievingPrismproduct‐ratedpowerforthePRUTxforwardpathspectrumRF.ThePAsarepass‐bandspecific,withthemaximumcompositeTxpowerlevels,and>10dBinstantaneouspeakpowerratinglistedin:•Table5forSingle‐Card,Dual‐Card,andHDMRFModules•Table6onpage14forDual‐Slot40WRFModules.TheLPAishousedwithintheRFModule,andisnotfieldserviceable.Table5.LPAMaximumCompositeTxPowerLevelsforSingle‐Card,Dual‐Card,andHDMRFModulesPassband MaximumdBmWatts InstantaneousBandwidth (MHz)AWS 2100 +43 20 45Cellular 850 +43 20 25+46  40 25EGSM 900 +40  10 35DCS 1800  +42  15.8 75LTE 700 Lower ABC +43  20 18+46  40 18LTE 700 Upper C +43  20 10+46  40 10PCS 1900 +43 20 70PGSM 900 +40 10 25SMR 800 +38 6.5 18SMR 900 +38 6.5 5UMTS 2100 +42  15.8 60
RF Module Components  Page 14 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2013 TE Connectivity Ltd TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013NOTE: IndustryCanada20dBPassBandModelNumberFWP‐C4MT000MODCellular850MHz=26.3MHzandthePCS1900=66.8MHz.DigitalProcessingModuleTheDigitalProcessingModule(DPM)isfoundonlyintheHDMRFModules.TheDPMprovidestheprimaryprocessingandlogicfunctionsfortheHDMRFModule.ItalsoprovidestheprimarypowerinterfacefortheHDMRFModule,andconversionofthenative28Vdcvoltagetolowervoltagesasnecessaryforfunctionality.TheDPMhasaTransmit(Tx)BoardandaReceive(Rx)Board:•TxBoard—providesbandspecificfilteringfortheintendedTransmitpath.•RxBoard—providesbandspecificfilteringfortheintendedReceivepath.Table6.LPAMaximumCompositeTxPowerLevelsforDual‐Slot40WRFModulesPassband MaximumdBmWatts InstantaneousBandwidth (MHz)PCS 1900 +46 40 70AWS 2100 +46 40 45
Power Cable ConnectionFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 15TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013 © 2013 TE Connectivity Ltd.UNDERSTANDINGTHERFMODULECABLESBeforeyouinstalltheRFModulecables,familiarizeyourselfwiththerulesthatpertaintothesecables,asdefinedinthefollowingsections.AlwaysprovidedateachRFModuleshelfarefivecables:•twoHigh‐SpeedDataCables,whichinthisdocumentarereferredtoasLVDS(Low‐VoltageDifferentialSignaling)cables•twoRFCables(TX0/RX0)and(TX1/RX1)•onePower(PWR)Cable.PowerCableConnectionMaintainadequatestrainreliefdistancesfromtheconnectionpointstothemodule.LVDSCableConnections•LVDScableslabeledPRIMandDIVshouldalwayseitherbeconnectedtoaRFModuleorstrainrelievedtoadjacentcables,asthisprotectsthecableagainstdamagethroughmisplacement.•AlignandfullyinserttheLVDScableconnectorsintotheirrespectiveconnectorcages.Fullinsertionisidentifiedbyanaudibleclick.•EnsurethetwoLVDScablesarefullyseatedandlatchedintotheirrespectivereceptaclesontheRFModulebylightlypullingoutwardontheconnectors.Iffullyseatedandlockedintoposition,thecableconnectorswillnotslidebackout.•Maintainadequatestrain‐reliefdistancesfromtheconnectionpointstotheRFModule.RFCableConnectionsTheRFModulecablesthatarepre‐installedinthePRUconnecttothecorrespondingconnectorsontheRFModule.TheRFModulecablescorrelatetotheantennaconnectorsonthebottomofthePRUchassis.
Understanding the RF Module Cables  Page 16 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2013 TE Connectivity Ltd TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013RFCableRules•WheninstallingaDiversity,MIMOorDual‐BandRFModule,bothRFcableslabeledMODNTX0/RX0andMODNTX1/RX1shallbeconnectedtotheN‐StyleconnectionsoftheRFModule.•WheninstallingaNon‐DiversityorSISORFModule:–TheMODNTX0/RX0cableshallbeconnectedtothesingleavailableN‐StyleRFConnectionoftheRFModule.–TheMODNTX1/RX1cableshallbeconstrainedtotheexistingcablesusingatiewraporsimilarlyacceptedfastenersoitcannotbepinchedorpreventthePRUdoorfromclosing.DonotcutorattempttootherwiseremovethisRFCable.•RFcablesarehand‐formable;however,cablesmustadheretoaminimumbendradiusof1‐inchfromtheoutletoftheintegratedcableguidetotherespectiveN‐StyleRFconnectionontheRFModule.RFModuleCablesforSingle‐Card,Dual‐Card,andHDMRFModulesTheRFcableandconnectorlabelsalsocorrespondtotheRFModuleslotsinthePRUchassis,whereMODAisthebottomslotandMODDisthetopslot.Intheinstallationsteps,theRFcablesandconnectorsarereferredtoasMODNTX0/RX0andasMODNTRX1whereNequalsA,B,C,orD.ThecablesandconnectorshavecorrespondinglabelsasshowninTable7forSingle‐Card,Dual‐Card,andHDMRFModules.Table7.RFAntennaLabelsforSingle‐Card,Dual‐Card,andHDMRFModules—FromTopofChassisDownRF Module Cable,RF Module Connector, and Remote Antenna Connector LabelFunctionSingle-SlotRemote Unit RF Module Slot DesignationsDual-Slot Remote Unit RF Module Slot DesignationsDual-Bay Tri-Bay Quad-BayMod D TX0/RX0Transmit RF power and primary receive to/from the antenna for RF Module DMOD D N/A N/A MOD CMod D TX1/RX1Diversity receive for RF power from the antenna for RF Module DMod C TX0/RX0 Transmit RF power and primary receive to/from the antenna for RF Module CMOD C N/A MOD BMod C TX1/RX1Diversity receive for RF power from the antenna for RF Module CMod B TX0/RX0 Transmit RF power and primary receive to/from the antenna for RF Module BMOD B MOD A MOD BMod B TX1/RX1Diversity receive for RF power from the antenna for RF Module BMod A TX0/RX0 Transmit RF power and primary receive to/from the antenna for RF Module AMOD A MOD A MOD AMod A TX1/RX1Diversity receive for RF power from the antenna for RF Module A
RF Cable ConnectionsFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 17TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013 © 2013 TE Connectivity Ltd.RFModuleCablesforDual‐SlotInstallationsForDual‐Slotinstallations,theRFcablesandconnectorsarelabeledasMODNTX0/RX0andMODNTX1/RX1,whereNreferstothebottomslotofthedouble‐slotinstallation.Forexample,foraDual‐SlotinstallationinaQuad‐Baychassis,theRFcablesandconnectorsarelabeledasMODCTX0/RX0andMODCTX1/RX1.ThecablesandconnectorshavecorrespondinglabelsasshowninTable8onpage17forDual‐Slot40WRFModules.Table8.RFAntennaLabelsforDual‐Slot40WRFModules(TopofChassisDown)RF Module Cable,RF Module Connector, and Remote Antenna Connector LabelsFunctionSlots for 40W RF Modules (a) (b)Dual-Bay Tri-Bay Quad-BayMod D TX0/RX0Transmit RF power and primary receive to/from the antenna for RF Module DN/A N/A Slots C and DMod D RX1 Diversity receive for RF power from the antenna for RF Module DMod C TX0/RX0 Transmit RF power and primary receive to/from the antenna for RF Module CN/A N/AMod C RX1 Diversity receive for RF power from the antenna for RF Module CMod B TX0/RX0 Transmit RF power and primary receive to/from the antenna for RF Module BSlots A and B Slots A and B Slots A and BMod B RX1 Diversity receive for RF power from the antenna for RF Module BMod A TX0/RX0 Transmit RF power and primary receive to/from the antenna for RF Module AMod A RX1 Diversity receive for RF power from the antenna for RF Module A(a) N/A indicates that the slot cannot be used for a Dual-Slot 40W RF Module(b) Install the Dual-Slot 40W RF Module in the lower-most slot in the chassis. If, however, if two Dual-Slot 40W RF Modules are present, install the 2100 Module in the lower-most slot and the 1900 Module in the upper-most slot.
Understanding the RF Module Cables  Page 18 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2013 TE Connectivity Ltd TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013RFGroupAssignmentsforPRUsA PRU comprises from one to four RF Module slots. Figure 7 illustrates the numbering of RF Module slots and DARTs.Figure 7. DART RF Groups in a Prism Remote Unit (PRU)Prism Quad-Band Remote Unit with Single-Card RF ModulesSeRF ModuleDART 7DART 8Group DDART 5DART 6Group CDART 3DART 4Group BDART 1DART 2Group A
RF Group Assignments for PRUsFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 19TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013 © 2013 TE Connectivity Ltd.Table 9 lists how the FlexWave Prism EMS references the RF group assignments and corresponding components of each RF Module.NOTE: In a dual-LPA system, the Configure Remote Forward Gain page shows two values for the LPA status, one for each LPA. Changing the LPA Mode or resetting the LPA applies to both LPAs at the same time.CAUTION! Should your system experience an LPA problem, refer to Table 9 to ensure that you apply new settings or troubleshoot the correct RF Module.CAUTION! If you use a customized SNMP polling for system status, you must change your LPA indexing scheme. Table 9. Remote Unit RF Group Assignments (from Top/Down)Physical RF SlotRF GroupDART NumberLNA Number LPA Numberfor Single LPALPA Number for Dual LPAsPower Detector Number for Single PDPower Detector Number for Dual PDsPrimary DiversityD D 8 8 78787 7 7 7C C 6 6 56565 5 5 5B B 4 4 34343 3 3 3A A 2 2 12121 1 1 1SeRF Board
Understanding the RF Module Cables  Page 20 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2013 TE Connectivity Ltd TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013TheDual‐Slot40WRFModuleoccupiestwoslotsinaPrismRemote.Figure8showsthemaincomponentsinaPrismenclosure,witha40WRFModuleoccupyingSlotsAandB.ThecontrollingDARTwillalwaysbeintheupperslot(BorD),andthesecondLPAisalwaysinthelowerslot(AorC).Figure8.Dual-Slot 40W RF Module in a Quad-Bay Prism RemoteNOTE: IfaDual‐Slot40WRFModuleAWS2100andaDual‐Slot40WRFModulePCS1900arebothinstalledinaQuad‐BayRemote,itisrecommendedthatthePCS1900beinstalledinupper‐mostslot,andtheAWS2100beinstalledinthelower‐mostslot.NOTE: Toaccommodatetwo‐slotmodules,youneedtoremoveamoduleslotshelfasdescribedin“Dual‐SlotModulesOnly—RemovetheModuleSlotShelf”onpage25.Dual-slot 40W RF Modulein Slot B (upper slot) and Slot A (lower slot) with the controlling DART in Slot Band the second DART in Slot AAC power switchFour DC power switchesSeRF Module and Power suppliesSlot C (empty for future use)Slot D (empty for future use)FansConnectivity panel with Status LED
Safety PrecautionsFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 21TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013 © 2013 TE Connectivity Ltd.INSTALLTHERFMODULE(S)ThefollowingsectionsguideyouthroughtheinstallationofanRFModuleintoaPRUchassis.TheprocesstoinstallthefourdifferenttypesofRFModulesisbasicallythesame;however,differencesarenotedandshouldbefollowed.NOTE: Inthefollowingsteps,theRFcablesandconnectorsarereferredtoasMODNTX0/RX0andasMODNTRX1whereNequalsA,B,C,orD.SafetyPrecautionsCAUTION! Thisisrestrictedaccessequipmentandonlyqualifiedservicepersonnelshouldserviceandoperatethisequipmentusingappropriatetools.CAUTION! Wetconditionsincreasethepotentialforreceivinganelectricalshockwheninstallingorusingelectrically‐poweredequipment.Topreventelectricalshock,neverinstalloruseelectricalequipmentinawetlocationorduringalightningstorm.CAUTION! Alwaysallowsufficientfiberlengthtopermitroutingofpatchcordsandpigtailswithoutseverebends.Fiberopticpatchcordsorpigtailsmaybepermanentlydamagedifbentorcurvedtoaradiusoflessthan2inches(5.1cm).CAUTION! ExteriorsurfacesofthePrismRemoteUnitmaybehot.Usecautionduringservicing.CAUTION! Servicepersonnelmustconfirmthattheperimetergasketanddoor‐to‐doorgasketsareinplacewhenclosingthePrismdoorsafterservicing.CAUTION! ThisequipmentusesaClass1LaseraccordingtoFDA/CDRHrules.Laserradiationcanseriouslydamagetheretinaoftheeye.Donotlookintotheendsofanyopticalfiber.Donotlookdirectlyintotheopticaltransceiverofanydigitalunitorexposuretolaserradiationmayresult.Anopticalpowermetershouldbeusedtoverifyactivefibers.AprotectivecaporhoodMUSTbeimmediatelyplacedoveranyradiatingtransceiveroropticalfiberconnectortoavoidthepotentialofdangerousamountsofradiationexposure.Thispracticealsopreventsdirtparticlesfromenteringtheadapterorconnector.CAUTION! ThissystemisanRFTransmitterandcontinuouslyemitsRFenergy.Maintain3foot(91.4cm)minimumclearancefromtheantennawhilethesystemisoperating.Whereverpossible,shutdowntheRANbeforeservicingtheantenna.
Install the RF Module(s)  Page 22 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2013 TE Connectivity Ltd TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013GuardagainstDamagefromElectro‐StaticDischargeCAUTION! Electro‐StaticDischarge(ESD)candamageelectroniccomponents.TopreventESDdamage,alwayswearanESDwriststrapwhenworkingwiththeIRUorwhenhandlinganyofitscomponents.ConnectthegroundwireontheESDwriststraptoanearthgroundsourcebeforetouchingtheIRUoranyofitscomponents.WearthewriststraptheentiretimethatyouworkwiththeIRUanditscomponents.CAUTION! PlacethePrismRFModulesinanti‐staticpackingmaterialwhentransportingorstoringthem.UnpackandInspecttheRFModule1Inspecttheexterioroftheshippingcontainer(s)forevidenceofroughhandlingthatmayhavedamagedthecomponentsinthecontainer.2Unpackeachcontainerwhilecarefullycheckingthecontentsfordamageandverifywiththepackingslip.3Ifdamageisfoundorpartsaremissing,fileaclaimwiththecommercialcarrierandnotifyTECustomerService(see“ContactingTEConnectivity”onpage46).Savethedamagedcartonsforinspectionbythecarrier.4Saveallshippingcontainersforuseiftheequipmentrequiresshipmentatafuturedate.CAUTION! HandletheRFModulewithcareduringinstallation.Beespeciallycarefultonotdamagethethermal‐interfacematerial(TIM),whichisattachedtotheLPA.IftheTIMisdamaged,theLPAcanoverheat.BeforeinstallingtheRFModule,checktoseeiftheheatsinkmaterialisgougedorcracked.IftheTIMisdamaged,donotinstalltheRFModuleandcontactTEConnectivityforassistance(see“ContactingTEConnectivity”onpage46forcontactinformation).CAUTION! Ifthethermal‐interfacematerialisdamaged,theinstallationanduseoftheRFModulemayvoidthewarrantyoftheRFModule.
Remove Release Liners from the RF ModuleFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 23TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013 © 2013 TE Connectivity Ltd.RemoveReleaseLinersfromtheRFModuleNOTE: ReleaseLinersarepresentonfrontandbackofnewmodules.1OpenthePRUenclosure.2Removereleaseliners,ifpresent,fromthethermalpadsontheRFModulepriortoinstallingthemoduleintothePRUchassis.CAUTION! Thethermalpadsareverysensitivetomishandling—donotnick,scratch,ordingthem.FormostRFModules,thethermalpadsarelocatedaslistedbelowandasshowninFigure9,whichshowsaDual‐Slot40WRFModule.•onelargepadonthebacksurfaceofeachLinearPowerAmplifier(LPA)•uptotwoonthefrontsurface(DARTs)•oneontheleftsideforthe(RDI)•oneonthevectormodulatorboard•oneontheRFpowercombiner.Figure9.Thermal Pads on a Dual-Slot 40W RF ModuleOne largethermal pad on each PA(bottom of the LPA)One thermal padfor the RDIOne thermal padfor each DARTOne thermal padfor each DARTOne thermal padfor RF PowerCombinerOne thermal padfor VectorModulator
Install the RF Module(s)  Page 24 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2013 TE Connectivity Ltd TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013ForHDMRFModules,thethermalpadsarelocatedaslistedbelowandasshowninFigure10.•onepadforeachRxandTxboard•onelargepadovertheDPM•oneforeachPowerAmplifier(PA),whichisonthebottomoftheHDMRFModule.Figure10.Thermal Pads on an HDM RF ModuleDPM Thermal PadTx A Thermal PadTx B Thermal PadRx A Thermal PadRx B Thermal Pad2.9796 in2.9796 inNOTE: Tx and Rx cards are paired: Tx A ony pairs with Rx A and Tx B only pairs with Rx B.
Dual-Slot Modules Only—Remove the Module Slot ShelfFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 25TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013 © 2013 TE Connectivity Ltd.Dual‐SlotModulesOnly—RemovetheModuleSlotShelf1ForDual‐SlotRFModulesonly.IfyouareinstallingaDual‐SlotRFModule,youmustremoveamoduleslotshelffromthePRUchassistoaccommodatethemodule’ssize.(Forfurtherinformation,seeTable7onpage16.)RemovetheshelfasappropriatefortheRFModule:•ForaDual‐Slot40WRFModule,removetheModuleBShelf.•ForaDual‐BayDual‐SlotRFModule,removeModuleDShelf.Toremovethemoduleshelf:aUsea9/64”Allen™wrenchtoremovethethreescrewsthatattachthemoduleshelftothePRUchassis,asshowninthefollowinggraphic.bDiscardorstorethemoduleshelfandfasteners.Use 9/64” Allen Wrench toremove the three module-shelf screwsRemove Module D Shelf forDual-Band Dual-Slot RF ModulesRemove Module B Shelf forDual-Slot 40W RF Modules
Install the RF Module(s)  Page 26 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2013 TE Connectivity Ltd TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013InstalltheRFModuleintothePrismRemoteChassisRecommendation: InstallDual‐BayDual‐Slotmodulesinthetwoupper‐mostslotsofthePRU.Recommendation: InstallDual‐Slot40Wmodulesinthebottom‐mostslotsofthePRU.Recommendation: IfbothaDual‐SlotAWS210040WRFModuleandaDual‐SlotPCS190040WRFModuleareinstalledinaQuad‐BayPRU,installtheAWS2100Moduleinthelower‐mostslotofthePRU.1HoldtheRFModulesothattheDARTcard(s)faceawayfromthePRUandtheMountingHookistowardtheReceivingflangeonthePRUchassis.NOTE: AlwaysinstallRFModulesfromthebottomup.Donotskipaslot.2HoldingtheRFModuleata45°angleinrespecttotherearheatsink,restthebottomsurfaceofthemoduleontheRFModuleshelf,asshowninoneofthefollowinggraphics,andasapplicabletotheRFModule.•Single‐SlotRFModule:Figure11onpage27•HDMRFModule:Figure12onpage28•Dual‐BayDual‐SlotRFModule:Figure13onPage29•Dual‐Slot40WRFModule:Figure14onPage30.
Install the RF Module into the Prism Remote ChassisFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 27TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013 © 2013 TE Connectivity Ltd.Figure11.Installing a Single-Slot RF ModuleRF MOD CRF MOD DSeRFModuleRF MOD ARF MOD BSingle-SlotRF ModuleHeat Sink
Install the RF Module(s)  Page 28 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2013 TE Connectivity Ltd TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013Figure12.Installing an HDM RF ModuleRF MOD CRF MOD DSeRFModuleRF MOD ARF MOD BHDM RF Module
Install the RF Module into the Prism Remote ChassisFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 29TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013 © 2013 TE Connectivity Ltd.Figure13.Installing a Dual-Bay Dual-Slot RF ModuleInstalling a Dual-BandDual-Slot RF Module
Install the RF Module(s)  Page 30 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2013 TE Connectivity Ltd TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013Figure14.Installing a Dual-Slot 40W RF Module
Install the RF Module into the Prism Remote ChassisFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 31TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013 © 2013 TE Connectivity Ltd.3AligntheMountingHookonthemodulewiththereceivingflangeonthePRUheatsink,andthenslidetheRFModuleintowardtheflangeuntilitcangonofurther.RF ModuleMountinghookChassisReceivingflange
Install the RF Module(s)  Page 32 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2013 TE Connectivity Ltd TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 20134PushtheleftedgeoftheRFModulebackandintothePRUchassisuntilitcangonofurther,asshowninthefollowinggraphics:•ForSingle‐SlotRFmodules,seeFigure15onpage32.•ForHDMRFmodules,seeFigure16onpage33.•ForDual‐SlotRFmodules,seeFigure17onpage34,whichusestheDual‐Slot40WRFModuleasanexample.CAUTION! MakesuretheRFModuleisseatedcorrectlyintheModuleshelf.IncorrectalignmentoftheRFModulecancausetheRFModuletofailduetooverheating.•ThefrontedgeoftheRFModuleshouldbeparallelwiththeshelfaboveit.•TheMountingHookontheRFModuleshouldbefullyengagedwiththeReceivingflangeonthePRUchassis.•IfyoulatercannotshutthePRUdoor,verifythattheRFModuleisinstalledcorrectly.Figure15.Seating a Single-Slot RF ModulePush the RF Moduleback into the chassisuntil it can go no further.Single-SlotRF Module
Install the RF Module into the Prism Remote ChassisFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 33TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013 © 2013 TE Connectivity Ltd.Figure16.Seating an HDM RF ModulePush the HDM RF Moduleback into the chassisuntil it can go no further.HDMRF Module
Install the RF Module(s)  Page 34 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2013 TE Connectivity Ltd TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013Figure17.Seating a Dual-Slot RF ModuleSecureRFModuleLatches1TosecurethemodulelatchesontheleftsideoftheRFModule,dooneofthefollowing,asappropriatefortheRFModulebeinginstalled:•“ConnectLatchesonSingle‐SlotandHDMRFModules”onpage35•“ConnectLatchesonDual‐BayDual‐SlotRFModules”onpage36.Push the RF Module backinto the chassis until it cango no further.
Secure RF Module LatchesFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 35TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013 © 2013 TE Connectivity Ltd.ConnectLatchesonSingle‐SlotandHDMRFModulesForSingle‐SlotandHDMRFModules,securetwolatches,asshowninFigure18.Figure18.Latches on Single-Slot and HDM RF ModulesTwo latches on Single-SlotRF ModulesTwo latches onHDM RF Modules
Install the RF Module(s)  Page 36 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2013 TE Connectivity Ltd TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013ConnectLatchesonDual‐BayDual‐SlotRFModulesForDual‐BayDual‐SlotRFModules,securefourlatches,asshowninFigure19.Figure19.Dual-Bay Dual-Slot RF Module LatchesFour latches in aDual-Band Dual-SlotRF Module
Connect the RF Module CablesFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 37TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013 © 2013 TE Connectivity Ltd.LatchesonDual‐Slot40WRFModulesForDual‐Slot40WRFModules,securefourlatches,asshowninFigure20.Figure20.Dual-Slot 40W RF Module LatchesVerifythattheRFModuleMountingHookisEngaged1VerifythattheRFModuleMountingHookisengagedcorrectlybypullingthemoduleawayfromtheheatsink.TheRFModuleshouldnotmove.IftheRFModulemovesduringthischeck,repeatallthestepsstartingat“InstalltheRFModuleintothePrismRemoteChassis”onpage26throughthisstep.ConnecttheRFModuleCablesThestepstoconnecttheRFModulecableshavebeenseparatedintotwodifferentprocedures;followthestepsthatcorrespondtotheRFModulebeinginstalled.•“ConnectingCablesinaSingle‐SlotRFModuleInstallation”onpage38•“ConnectingCablesinaDual‐SlotRFModuleInstallation”onpage40.Four latches ina Dual-Slot 40WRF Module
Install the RF Module(s)  Page 38 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2013 TE Connectivity Ltd TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013ConnectingCablesinaSingle‐SlotRFModuleInstallation1PositionthecablessothattheyareundertherightedgeoftheRFModule,pointingup.2Followtheruleslistedin“UnderstandingtheRFModuleCables”onpage15.3Workingfromthebottomconnectorup,connecttheRFModulecables,asfollows:aConnecttheMODNTX1/RX1cabletotheRFModule.iIfaTX1/RX1RFModuleconnectionisavailable,inserttheN‐StylePlugoftheMODNTX1/RX1cableintotheTX1/RX1N‐StyleJackoftheRFModule.If RF Moduleconnection is not available, constrain the MOD N TX1/RX1 cable toaccompanyingcablesusingatiewrapsoitcannotbepinchedorpreventthePRUdoorfromclosing.ii Turnthecouplingnutoftheplugclockwisetothreadontothejackandfinger‐tighten.iii Torquecouplingnutto8+/‐1in‐lbstoensurefullconnection.NOTE: InsufficienttorqueappliedtoRFModuleconnectionscanresultinelevatedinsertion/returnlossandhigherthannormalVSWRreportedbythesystem.bConnecttheMODNTX0/RX0cabletotheRFModule.iInserttheN‐StylePlugoftheMODNTX0/RX0cableintotheTX0/RX0N‐StyleJackoftheRFModule.ii Turnthecouplingnutoftheplugclockwisetothreadontothejackandfinger‐tighten.iii Torquecouplingnutto8+/‐1in‐lbstoensurefullconnection.NOTE: InsufficienttorqueappliedtoRFModuleconnectionscanresultinelevatedinsertion/returnlossandhigherthannormalVSWRreportedbythesystem.cConnecttheLVDSCablestotheRFModule.iConnect the MOD N DIV LVDS Cable to the DIV receptacle of the RF Module byinsertingandslidinginuntilfullyseated.NOTE: AlwaysconnecttheDiversityLVDSCablewiththeRFModule.ii ConnecttheMODNPRIMLVDSCabletothePRIMconnector,followingthesamestepsasabove.NOTE: FullinsertioncanberecognizedbyanaudibleclickastheLVDSCableConnectorlocksintotheRFModuleReceptacle.ThiscanbeverifiedbylightlypullingbackontheLVDSconnectorwhilemakingsurenottodepressthereleasetrigger.Whenfullyinserted,thecableshouldnotbeabletoberemovedfromthereceptacle.dConnectthePowerCableConnectortothePWRreceptacleoftheRFModulebyinsertingandslidinginuntilfullyseated.NOTE: FullinsertioncanberecognizedbyanaudibleclickasthePowerCableConnectorlocksintotheRFModuleReceptacle.ThiscanbeverifiedbylightlypullingbackonthePowerCableConnectorwhilemakingsurenottodepressthereleasetriggersontheendsoftheconnector.Whenfullyinserted,thecableshouldnotbeabletoberemovedfromthereceptacle.
Connect the RF Module CablesFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 39TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013 © 2013 TE Connectivity Ltd.RefertothegraphicthatcorrespondstotheRFModulebeinginstalledintoasingleslot(bay)ofthePRU:•Single‐SlotRFModule:Figure21onPage39•HDMRFModule:Figure22onpage40Figure21.Cable Connections for Single-Slot RF ModulesCAUTION! EnsurethatallcablebendsarebelowthetopedgeoftheConnectorInterfacePanelasindicatedbythedashedlineintheprecedingfigure.FailuretocorrectlypositionthecablescouldinhibitclosingthePRUdoor,whichcanresultindamagetothecables.MOD AMOD DMOD CMOD BSeRFModuleTX0/RX0RX1DIVPRIMPWRNote routing ofhigh-speed cablesNote bendradii ≥ 1-inchEdge of Connector Interface PanelCable connections for a Single-Slot RF Module
Install the RF Module(s)  Page 40 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2013 TE Connectivity Ltd TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013Figure22.Cable Connections for HDM RF ModulesConnectingCablesinaDual‐SlotRFModuleInstallation1PositionthecablessothattheyareundertherightedgeoftheRFModule,pointingup.2Followtheruleslistedin“UnderstandingtheRFModuleCables”onpage15.3FollowtheruleslistedbelowthatpertainonlytoDual‐SlotRFModules.•TheupperRFModuleshelfwilleithernotbepresent(factoryinstalledmodule)orwillberemovedpriortoinstallation(fieldinstalledmodule).•TheMODNTX0/RX0cableforthelowerRFModuleslotwillneedtobeconnectedtotheMODNTX0/RX0N‐StyleRFconnectionoftheDual‐SlotRFModule.•ConstraintheMODNTX1/RX1cabletotheexistingcablesusingatiewrapsuchsoitcannotbepinchedorpreventthePRUdoorfromclosing.DonotcutorattempttootherwiseremovethisRFcable.•ThePower(PWR)cableandtwoLVDScablesoftheupperRFModuleslotarenotusedwheninstallingaDual‐SlotRFModule.Cable Connections for an HDM RF ModuleTX0/RX0TX1/RX1POWERDATA 1 (DIV)DATA 0 (PRIM)Cable Connection Notes• Always connect the Power cable.• Always connect the two LVDS cables: PRIM and DIV.• SISO requires one RF cable (TX1/RX1).• MIMO and Dual-Band require two RF cables   (TX1/RX1 and TX0/RX0).
Connect the RF Module CablesFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 41TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013 © 2013 TE Connectivity Ltd.4Workingfromthebottomconnectorup,connecttheRFModulecables,asfollows:aConnecttheMODNTX1/RX1cabletotheRFModule.NOTE: DonotremoveanyfactoryconnectedRFCables.iConstraintheMODNTX1/RX1cableofthelowerRFModuleslottoaccompanyingcablesusingatiewrapsoitcannotbepinchedorpreventthePRUdoorfromclosing.ii ConnecttheMODNTX1/RX1cabletotheTX1/RX1orN/C,N‐StyleJackoftheupperRFModuleslot.iii Turnthecouplingnutoftheplugclockwisetothreadontothejackandfinger‐tighten.iv Torquecouplingnutto8+/‐1in‐lbstoensurefullconnection.NOTE: InsufficienttorqueappliedtoRFModuleconnectionscanresultinelevatedinsertion/returnlossandhigherthannormalVSWRreportedbythesystem.bConnecttheMODNTX0/RX0cabletotheRFModule.NOTE: DonotremoveanyfactoryconnectedRFCables.iIfTX0/RX0RFModuleconnectionisavailable,inserttheN‐StylePlugoftheMODNTX0/RX0cableintotheTX0/RX0N‐StyleJackofthelowerRFModule slot. If RFModule connection is not available, constrain the MOD N TX0/RX0cabletoaccompanyingcablesusingatiewrapsoitcannotbepinchedorpreventthePRUdoorfromclosing.ii Turnthecouplingnutoftheplugclockwisetothreadontothejackandfinger‐tighten.iii Torquecouplingnutto8+/‐1in‐lbstoensurefullconnection.iv IfTX0/RX0RFModuleconnectionisavailable,inserttheN‐StylePlugoftheMODNTX0/RX0cableintotheTX0/RX0N‐StyleJackoftheupperRFModule slot. If RFModule connection is not available, constrain the MOD N TX0/RX0cabletoaccompanyingcablesusingatiewrapsoitcannotbepinchedorpreventthePRUdoorfromclosing.vTurnthecouplingnutoftheplugclockwisetothreadontothejackandfinger‐tighten.vi Torquecouplingnutto8+/‐1in‐lbstoensurefullconnection.NOTE: InsufficienttorqueappliedtoRFModuleconnectionscanresultinelevatedinsertion/returnlossandhigherthannormalVSWRreportedbythesystem.
Install the RF Module(s)  Page 42 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2013 TE Connectivity Ltd TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013cConnecttheLVDSCablestotheRFModule.iIfavailable,connecttheMODNDIVLVDSCabletotheDIVreceptacleofthelowerRFModulebyinsertingandslidinginuntilfullyseated.IfDIVreceptacleisnotavailable,constraintheMODNDIVLVDSCabletoaccompanyingcablesusingatiewrapsoitcannotbepinchedorpreventthePRUdoorfromclosing.ii Ifavailable,connecttheMODNPRIMLVDSCabletothePRIMreceptacleofthelowerRFModulebyinsertingandslidinginuntilfullyseated.IfDIV receptacle is notavailable,constraintheNPRIMLVDSCabletoaccompanyingcablesusingatiewrapsoitcannotbepinchedorpreventthePRUdoorfromclosing.iii Ifavailable,connecttheMODNDIVLVDSCabletotheDIVreceptacleoftheupperRFModulebyinsertingandslidinginuntilfullyseated.IfDIVreceptacleisnotavailable,constraintheMODNDIVLVDSCabletoaccompanyingcablesusingatiewrapsoitcannotbepinchedorpreventthePRUdoorfromclosing.iv Ifavailable,connecttheMODNPRIMLVDSCabletothePRIMreceptacleoftheupperRFModulebyinsertingandslidinginuntilfullyseated.IfDIV receptacle is notavailable,constraintheNPRIMLVDSCabletoaccompanyingcablesusingatiewrapsoitcannotbepinchedorpreventthePRUdoorfromclosing.NOTE: FullinsertioncanberecognizedbyanaudibleclickastheLVDSCableConnectorlocksintotheRFModuleReceptacle.ThiscanbeverifiedbylightlypullingbackontheLVDSconnectorwhilemakingsurenottodepressthereleasetrigger.Whenfullyinserted,thecableshouldnotbeabletoberemovedfromthereceptacle.dConnectthePowercabletotheRFModule.iConnectthePowerCableConnectortothePWRreceptacleofthelowerRFModulebyinsertingandslidinginuntilfullyseated.ii Ifavailable,connectthePowerCableConnectortothePWRreceptacleoftheupperRFModulebyinsertingandslidinginuntilfullyseated.IfPWRreceptacleisnotavailable,constrainthePowerCabletoaccompanyingcablesusingatiewrapsoitcannotbepinchedorpreventthePRUdoorfromclosing.NOTE: FullinsertioncanberecognizedbyanaudibleclickasthePowerCableConnectorlocksintotheRFModuleReceptacle.ThiscanbeverifiedbylightlypullingbackonthePowerCableConnectorwhilemakingsurenottodepressthereleasetriggersontheendsoftheconnector.Whenfullyinserted,thecableshouldnotbeabletoberemovedfromthereceptacle.RefertothegraphicthatcorrespondstotheRFModulebeinginstalledinadual‐slot:•Dual‐BayDual‐SlotRFModule:Figure23onPage43•Dual‐Slot40WRFModule:Figure24onPage44.
Connect the RF Module CablesFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 43TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013 © 2013 TE Connectivity Ltd.Figure23.Cable Connections for Dual-Bay Dual-Slot RF ModulesCable Connections for a Dual-Slot RF ModuleTie wrapFactory-installedRX1 cableTwo N-TypeRF connectorsN-TypeRF connector
Install the RF Module(s)  Page 44 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2013 TE Connectivity Ltd TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013Figure24.Cable Connections for Dual-Slot 40W RF ModulesCAUTION! EnsurethatallcablebendsarebelowthetopedgeoftheConnectorInterfacePanelasindicatedbythedashedlineintheprecedingfigure.FailuretocorrectlypositionthecablescouldinhibitclosingthePRUdoor,whichcanresultindamagetothecables.Tie wrap around factory-installedRX1 cableKeep cable bendsbehind the edge of the Connector Interface Panel
Power on the RF ModuleFlexWave Prism RF Modules for Prism Remote Units Installation Guide Page 45TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013 © 2013 TE Connectivity Ltd.PowerontheRFModule1FollowtheruleslistedbelowtotogglethePowerswitchthatcorrespondstotheRFModuletoitsONposition.•ForDual‐SlotRFModules,usethePowerswitchforthelowermodule.Forexample,topowerupaDual‐SlotRFModuleincombinedslotsC+DinaQuad‐Baychassis,turnONDCPowerswitchforModC;leavetheDCPowerswitchforModDOFF.•ADual‐Slot40WRFModuleusesthePowerSuppliesinbothslots.IftheDual‐Slot40WRFModuleisinstalledinslotsC+D,turnONthePowerswitchforModCandModD.2Repeatallthestepsin“InstalltheRFModule(s)”onpage21toinstallotherRFModules.MOD ASeRFModuleAC Powerswitch forRemotechassisDC Power switch for Mod ADC Power switch for Mod BDC Power switch for Mod CDC Power switch for Mod DMOD BMOD CMOD D
Contacting TE Connectivity  Page 46 FlexWave Prism RF Modules for Prism Remote Units Installation Guide© 2013 TE Connectivity Ltd TECP-77-141 Issue 5  •  300001744178 Rev E  •  November 2013CONTACTINGTECONNECTIVITYContactingTEConnectivitybyTelephoneContactingTEConnectivityOnlineClickononeofthefollowingURLs,orpasttheURLintoyourwebbrowser.SalesAsia Pacific +65-6294-9948France 0800 914032Germany 0180 2232923Italy 0800 782374Spain 900 983291United Kingdom 0800 960236USA or Canada 1-800-366-3891Extension 73000Connectivity Extension 73475Wireless Extension 73476Technical SupportUSA or Canada 1-800-530-9960Elsewhere +1-952-917-0761Customer Portalhttps://www.te.com/portal/wireless/Technical Support for Wireless Productshttp://www.te.com/WirelessSupport
www.te.com/wireless

Navigation menu