ADCP-75-348 • Issue 1 • 04/2008Page 18© 2008, ADC Telecommunications, Inc.6.8.1 Optical Connections Without WDM SystemUse the following procedure to connect the optical fibers when there is no WDM installed with the HU:1. Obtain two patch cords that are of sufficient length to reach from the HU to the fiber distribution panel. 2. Designate one of the patch cords as the forward path link and the other as the reverse path link and attach an identification label or tag next to the connector. 3. Remove the dust caps from the HU SeRF SFP optical ports and from the patch cord connectors that will be connected to the SeRF SFP optical ports. 4. Clean each patch cord connector following the patch cord supplier’s recommendations. 5. Insert each patch cord connector into the appropriate optical port as shown in Figure 13and as specified by the following:PORT 1 FWD - Forward path patch cordPORT 1 REV - Reverse path patch cord6. Route the patch cords from the HU to the fiber distribution panel. 7. At the fiber distribution panel, identify the OSP cable optical fiber terminations that correspond to the forward and reverse paths. 8. Remove the dust caps from the OSP cable optical fiber adapters and from the patch cord connectors. 9. Clean each patch cord connector (follow patch cord supplier’s recommendations) and then mate the connector with the appropriate OSP cable adapter. Danger: This equipment uses a Class 1 Laser according to FDA/CDRH rules. Laser radiation can seriously damage the retina of the eye. Do not look into the ends of any optical fiber. Do not look directly into the optical transmitter of any unit or exposure to laser radiation may result. An optical power meter should be used to verify active fibers. A protective cap or hood MUST be immediately placed over any radiating transmitter or optical fiber connector to avoid the potential of dangerous amounts of radiation exposure. This practice also prevents dirt particles from entering the connector. Note: To protect the optical receivers, insert a 15 dB attenuator in each optical path. When the system is turned-up and tested, the attenuator may be resized or removed.Caution: Improper handling can damage fiber optic cables. Do not bend fiber optic cable more sharply than the minimum recommended bend radius specified by the cable manufacturer. Do not apply more pulling force to the cable than specified.Note: The HU optical adapters are angled to the left. Therefore, always route patch cords to the HU from the left side of the rack. Routing patch cords to the HU from the right may exceed the bend radius limitations for the optical fiber.
ADCP-75-348 • Issue 1 • 04/2008Page 19© 2008, ADC Telecommunications, Inc.Figure 13. Fiber Optic Cable Connections To Host Unit10. Repeat this procedure for the remaining SeRF SFPs in the HU.11. Store any excess patch cord slack at the fiber distribution panel or storage panel. 6.8.2 Optical Connections For Systems With a WDMUse the following procedure to connect the optical fibers when a WDM module is installed with the HU: 1. Obtain a patch cord that is of sufficient length to reach from the WDM module to the fiber distribution panel. 2. Remove the dust cap from WDM Port or Port 4 on the WDM module and from the patch cord connector that will be connected to the WDM module. Note: WDM module ports are labeled FWD, REV, TEST, and WDM.22410 -APORT 8 FWD(FORWARD PATH)PORT 8 REV(REVERSE PATH)
ADCP-75-348 • Issue 1 • 04/2008Page 20© 2008, ADC Telecommunications, Inc.Figure 14. Fiber Optic Connections To WDM Module3. Clean the patch cord connector (follow patch cord supplier’s recommendations). 4. Insert the connector into the WDM module optical WDM port (port 4). 5. Route the patch cord from the WDM to the fiber distribution panel or storage panel. 6. Identify the OSP cable optical fiber termination that corresponds to the RU. 7. Remove the dust cap from the OSP cable optical adapter and from the patch cord connector. 8. Clean the patch cord connector (follow patch cord supplier’s recommendations) and then mate the connector with the appropriate OSP cable adapter. 9. Store any excess patch cord slack at the fiber distribution panel. 10. Obtain two patch cords that are of sufficient length to reach from the WDM module to the HU.11. Designate one of the patch cords as the forward path link and the other as the reverse path link and attach an identification label or tag next to the connector. 12. Remove the dust caps from the HU SeRF SFP optical ports and from the patch cord connectors that will be connected to the SeRF SFP optical ports. 13. Clean each pigtail connector (follow the procedures provided with the WDM module) and then insert the connector into the appropriate optical port on the HU as shown in Figure 13and as diagramed in Figure 14.Note: To protect the optical receivers, insert a 15 dB attenuator in each optical path. When the system is turned-up and tested, the attenuator may be resized or removed.FIBER DISTRIBUTIONPANEL (FDP)XXHOST UNIT 1PORT 8FWDPORT 8REVREVERSEPATHFORWARDPATHWAVELENGTHDIVISIONMULTIPLEXERS1234PORT 1FWDPORT 1REVHOST UNIT 2REVERSEPATHFORWARDPATH22416-ATO/FROMREMOTE UNIT 1TO/FROMREMOTE UNIT 1HOST UNIT 1(BI-DIRECTIONAL FIBERLINK WITH REMOTE UNIT)HOST UNIT 1(BI-DIRECTIONAL FIBERLINK WITH REMOTE UNIT)PORT 1FWDPORT 1REVREVERSEPATHFORWARDPATH1234TESTTEST1234TESTFIBER DISTRIBUTIONPANEL (FDP)XTO/FROMREMOTE UNIT 2HOST UNIT 2(BI-DIRECTIONAL FIBERLINK WITH REMOTE UNIT)
ADCP-75-348 • Issue 1 • 04/2008Page 21© 2008, ADC Telecommunications, Inc.6.9 EXT REF ConnectionsEXT REF connections between multiple HU’s is supported through two QMA type female connectors mounted on the System card. One of the jacks is designated as the IN port and the other jack is designated as the OUT port. The EXT REF interface allows HU’s to be connected together (in daisy-chain fashion) and clocked through a single source. Use the following procedure to connect EXT REF interface cables between multiple HU’s: 1. Connect one end of the EXT REF interface cable (accessory) to either the IN or OUT port on HU #1 as shown in Figure 15. Figure 15. EXT REF Connections2. Route the EXT REF interface cable to HU #2 and connect the cable’s free end to the port that is the logical opposite of the EXT REF interface connection at HU #1. Note: The HU SeRF SFP optical adapters are angled to the left. Therefore, pigtails should always be routed to the HU from the left side of the rack. Routing pigtails to the HU from the right side of the rack may exceed the bend radius limitations for the optical fiber. Note: When using the 10 MHz external reference clock the signal must be connected to the HU before enabling the clock source in the software.22407-A
ADCP-75-348 • Issue 1 • 04/2008Page 22© 2008, ADC Telecommunications, Inc.3. If a third HU will be connected to the network, connect a second EXT REF interface cable to the remaining network port on HU #2. 4. Route the second EXT REF interface cable to HU #3 and connect the cable’s free end to the port that is the logical opposite of the EXT REF interface connection at HU #2. 5. Repeat steps 3 and 4 for each additional HU that is added to the network. A diagram of typical EXT REF interface connections is shown in Figure 16. Figure 16. Configuring EXT REF Connections with Multiple Host Units6.10 Computer Connection (CRAFT)The service interface connection between the HU and the computer is supported by a single RJ-45 connector. Use the following procedure to install the service interface cable: 1. Connect one end of the service interface cable (accessory) to the CRAFT port as shown in Figure 17. 2. Route the service interface cable to the computer and connect the free end of the cable to the computer’s port. Refer to the user manual provided with the computer to locate and configure the specified port. Note: Connect OUT to IN and IN to OUT. If connected to a EXT REF OUT port at HU #1, connect to the EXT REF IN port at HU #2. If connected to a EXT REF IN port at HU #1, connect to a EXT REF OUT port at HU #2. HOST UNIT 3 HOST UNIT 2 HOST UNIT 1OUT  EXT   IN NET IN NET OUT NET IN NET OUT22414-ACOAXIALINTERFACE CABLESTO NEXT HOST UNIT(NOTE: LAST HOST HAS NOCONNECTION AT EXT OUT)OUT  EXT   IN OUT  EXT   INREF CLOCKINPUT
ADCP-75-348 • Issue 1 • 04/2008Page 23© 2008, ADC Telecommunications, Inc.Figure 17. Craft Interface and Network Interface Connections6.11 Network ConnectionA network connection between the HU and the network is used to monitor and configure the FlexWave URH system through a single IP connection. Use the following procedure to install the network interface cable: 1. Connect one end of the cable (accessory) to the NETWORK port as shown in Figure 17. 2. Route the cable to the computer and connect the free end of the cable to the computer’s port. Refer to the user manual provided with the computer to locate and configure the specified port. 22403-ARJ-45CONNECTORDETAIL
ADCP-75-348 • Issue 1 • 04/2008Page 24© 2008, ADC Telecommunications, Inc.6.12 System Alarm System ConnectionsThe alarm interface between the HU and an alarm system is supported by twelve-terminal plug (with screw-type terminals) that connects to a receptacle mounted on the HU System card front panel. The terminal plug provides connections to normally open (NO) and normally closed (NC) dry type alarm contacts for both major and minor alarms. A category 3 or 5 cable is typically used to connect the HU System card to the alarm system. Use the following procedure to install the alarm wiring and connect it to the HU: 1. Obtain the required length of category 3 or 5 cable. 2. Route the cable between the HU System card and the alarm system (if not already routed) and then cut to the required length. Allow sufficient slack for dressing and organizing the cable at the HU.3. Strip back the outer cable sheath and insulation to expose the wires at both ends of the cable and strip back 0.2 inches (5 mm) of insulation from each wire. 4. Connect the Major alarm wire pair to the MAJOR COM/NC or MAJOR COM/NO terminals (whichever is required by the alarm system) on the HU System card alarm terminal connector (supplied with HU System card) as shown in Figure 18. 5. Connect the Minor alarm wire pair to the MINOR COM/NC or MINOR COM/NO terminals (whichever is required by the alarm system) on the HU System card alarm terminal connector (see Figure 18 and Table 4). 6. Connect the Major and Minor alarm wire pairs to the appropriate terminals on the external alarm system. 7. Dress and secure cable per standard industry practice. Table 4. System Card Alarm Pin DesignationsPIN DESCRIPTION1Host Minor Normally Closed2Host Minor Common3Host Minor Normally Open4Host Major Normally Closed5Host Major Common6Host Major Normally Open7Remote Minor Normally Closed8Remote Minor Common9Remote Minor Normally Open10 Remote Major Normally Closed11 Remote Major Common12 Remote Major Normally Open
ADCP-75-348 • Issue 1 • 04/2008Page 25© 2008, ADC Telecommunications, Inc.Figure 18. Alarm System Connections6.13 Power ConnectionsHU is powered by a modular power supply located on the lower left side of the chassis. An On/Off switch is provided on the HU power supply module front panel.6.13.1 DC Power ConnectionsThe HU is powered by ± 20 to 60 VDC power (nominal ± 24 or ± 48 VDC), install DC Power Supply in the lower left side of the HU chassis. Secure in place by turning screws clock-wise until tight.22406-APIN 12PIN 1
ADCP-75-348 • Issue 1 • 04/2008Page 26© 2008, ADC Telecommunications, Inc.A three position terminal block is provided for connecting the power wires. The power is fed to the HU Power Supply module through a connector located on the front of the unit. Power to the HU must be supplied through a fuse panel such as the 20 position PowerWorx GMT Fuse Panel (available separately) and the power must be protected with a 15 Amp GMT fuse. Use the following procedure to install the power wiring: 1. Obtain the items listed below:• Wire stripper and screwdriver•Wire, #18 AWG (1.00 mm) red and black insulated copper wire. Recommended wire size for the power leads, when fused in the same bay.2.Turn power switch on power supply OFF. 3. Connect the wires to the designated terminals on the fuse panel.4. Dress and secure the wires to the rack following local practice. Route wiring away from sharp edges and secure in place to prevent chaffing and provide strain relief.5. Route the wires to the terminal block (Figure 19) on the HU Power Supply and cut them to length, allowing sufficient length for termination.6. Loop both power wires around and through the Ferrite as shown in Figure 19.7. Strip 1.27 cm (0.5 inch) of insulation from the end of each wire.8. Insert one end of each wire into the terminal block, one into + and the other into the – position.9. The terminal block must plug into the three-pin receptacle on the front of the HU Power Supply. 10. Install fuses in the fuse panel. Update office records as required.11.Turn power switch on power supply ON.12. The procedure for checking the voltage level and verifying that the HU is ready to power up is provided in the applicable System Operation and Maintenance Manual (see Related Publications section).Note:  All DC input wiring should be routed away from any sharp edges and properly secured in place to prevent chafing and to provide strain relief. This may be achieved by tie-wrapping wires to the rack frame or by a similar means.Note: When connecting the equipment to the supply circuit, be sure to check equipment nameplate ratings to avoid overloading circuits which may cause damage to over-current protection devices and supply wiring.
ADCP-75-348 • Issue 1 • 04/2008Page 27© 2008, ADC Telecommunications, Inc.Figure 19. DC Power Connections6.14 Installation CompleteWhen the installation is complete, refer to the applicable System User Manual (see Related Publications section) for the system turn-up and test procedures. 7 MAINTENANCEThis section provides the HU maintenance procedures. Refer to this section when scheduled maintenance is required. The fault isolation and troubleshooting procedures are provided in the applicable System Operation and Maintenance Manual (see Related Publications section). Host Unit card locations are shown in Figure 20.22405-AFERRITE
ADCP-75-348 • Issue 1 • 04/2008Page 28© 2008, ADC Telecommunications, Inc.Figure 20. Host Unit Card Locations7.1 Host Unit Fan Replacement ProcedureThe HU is equipped with a fan assembly consisting of two cooling fans which is located on the left side of the HU enclosure. The cooling fans blow cool air into the enclosure. Heated air is exhausted through the vent openings on the right side of the enclosure. Replacement of fan assembly does not require that the HU be turned off. The recommended replacement interval is 60 months. Use the following procedure to remove and replace the HU cooling fans: 1. Before working on the HU or handling a fan, slip on an Electro-Static Discharge (ESD) wrist strap and connect the ground wire to an earth ground source. Wear the ESD wrist strap while completing each section of the fan installation procedure. 2. Notify the NOC or alarm monitoring system operator that the fan is being replaced. 3. Loosen the two thumb screws that secure the fan/grill assembly to the front of the HU enclosure as shown in Figure 21.4. Carefully withdraw the fan/grill assembly from the enclosure. 5. Slide the new fan assembly into the HU chassis until it is firmly seated.6. Secure the fan/grill assembly to the front of the enclosure (see Figure 21) using the two screws loosened in Step 3. 7. Verify that the fans run properly following power-up. 8. Notify the NOC or alarm monitoring system operator that the fans are back in operation. Warning:  Electronic components can be damaged by static electrical discharge. To prevent ESD damage, always wear an ESD wrist strap when working on the HU and when handling electronic components. SeRF CARDSYSTEM CARDPOWER SUPPLYDART CARDDART CARDDART CARDDART CARDDART CARDDART CARDDART CARDDART CARDFAN ASSEMBLY22402-A
ADCP-75-348 • Issue 1 • 04/2008Page 29© 2008, ADC Telecommunications, Inc.Figure 21. Host Unit Fan Assembly Removal7.2 Power Supply Replacement ProcedureRemoving the power supply will disable the Host Unit and interrupt service. Notify the NOC or alarm monitoring system operator that the system will be out of service for a period of time. 1. Before working on the HU or handling a power supply, slip on an Electro-Static Discharge (ESD) wrist strap and connect the ground wire to an earth ground source. Wear the ESD wrist strap while completing each section of the fan installation procedure. 2. Turn power switch to the OFF position. 3. Unplug power plug by applying pressure to the left and right side of the connector and pulling it straight out.4. Loosen the two thumb screws that secure the Power Supply to the front of the HU enclosure. See Figure 22.5. Carefully withdraw the Power Supply from the enclosure. 6. Slide replacement Power Supply into the HU chassis until it is firmly seated.7. Secure the Power Supply to the front of the enclosure using the two thumb screws loosened in Step 4.8. Plug power plug into the power connector on the front of the Power Supply. Make certain that it is fully seated.Warning:  Electronic components can be damaged by static electrical discharge. To prevent ESD damage, always wear an ESD wrist strap when working on the HU and when handling electronic components. 22396-AFANASSEMBLYTHUMBSCREWS
ADCP-75-348 • Issue 1 • 04/2008Page 30© 2008, ADC Telecommunications, Inc.Figure 22. Power Supply Replacement9. Turn power switch to the ON position.10. Notify the NOC or alarm monitoring system operator that the system is back in operation. 7.3 System Card Replacement ProcedureSystem Card can be replaced without disrupting service. If the EXT REF is being used communications to other HU’s will be disrupted.1. Before working on the HU or handling a System Card, slip on an Electro-Static Discharge (ESD) wrist strap and connect the ground wire to an earth ground source. Wear the ESD wrist strap while completing each section of the fan installation procedure. 2. Notify the NOC or alarm monitoring system operator that the System Card is being replaced.3. If used, disconnect EXT REF cables from the front of the System Card.4. Remove alarm plug from the front of the System Card by pressing on the lock tabs.5. Loosen the two thumb screws that secure the System Card to the front of the HU enclosure. See Figure 23.Warning:  Electronic components can be damaged by static electrical discharge. To prevent ESD damage, always wear an ESD wrist strap when working on the HU and when handling electronic components. 22400-A
ADCP-75-348 • Issue 1 • 04/2008Page 31© 2008, ADC Telecommunications, Inc.6. Carefully withdraw the System Card from the enclosure. 7. Slide replacement System Card into the HU chassis until it is firmly seated.8. Secure the System Card to the front of the enclosure using the two thumb screws loosened in Step 5.9. If used, connect EXT REF cables to the front of the System Card.10. Plug alarm plug into the connector on the System Card.11. On the Power Supply turn the power switch OFF and then back ON to reset the System Card.12. Notify the NOC or alarm monitoring system operator that the system is back in operation. Figure 23. System Card Replacement7.4 SeRF Card Replacement ProcedureRemoving the SeRF Card will disable the Host Unit and interrupt service. Notify the NOC or alarm monitoring system operator that the system will be out of service for a period of time. 1. Before working on the HU or handling a SeRF Card, slip on an Electro-Static Discharge (ESD) wrist strap and connect the ground wire to an earth ground source. Wear the ESD wrist strap while completing each section of the fan installation procedure. Warning:  Electronic components can be damaged by static electrical discharge. To prevent ESD damage, always wear an ESD wrist strap when working on the HU and when handling electronic components. 22398-A
ADCP-75-348 • Issue 1 • 04/2008Page 32© 2008, ADC Telecommunications, Inc.2. Remove Network and Craft RJ-45 plugs from the front of the SeRF Card.3. Remove fiber pigtails from the SFP’s. Note the location of the pigtails.4. Loosen the two thumb screws that secure the System Card to the front of the HU enclosure. See Figure 24.Figure 24. SeRF Card Replacement5. Use the two handles to carefully withdraw the SeRF Card from the enclosure. 6. Slide replacement SeRF Card into the HU chassis until it is firmly seated.7. Secure the SeRF Card to the front of the enclosure using the two thumb screws loosened in Step 4.8. If necessary install new SFP’s or remove them from the SeRF card removed in Step 5 and install them in the new SeRF Card.9. Plug fiber pigtails back into the SFP’s.Danger: This equipment uses a Class 1 Laser according to FDA/CDRH rules. Laser radiation can seriously damage the retina of the eye. Do not look into the ends of any optical fiber. Do not look directly into the optical transmitter of any unit or exposure to laser radiation may result. An optical power meter should be used to verify active fibers. A protective cap or hood MUST be immediately placed over any radiating transmitter or optical fiber connector to avoid the potential of dangerous amounts of radiation exposure. This practice also prevents dirt particles from entering the connector. Caution: Improper handling can damage fiber optic cables. Do not bend fiber optic cable more sharply than the minimum recommended bend radius specified by the cable manufacturer. Do not apply more pulling force to the cable than specified.22397-AHANDLES
ADCP-75-348 • Issue 1 • 04/2008Page 33© 2008, ADC Telecommunications, Inc.10. Plug Network and Craft RJ-45 plugs into the connector on the SeRF Card. Make certain the pigtails are inserted in the correct SFP.11. Notify the NOC or alarm monitoring system operator that the system is back in operation. 7.5 DART Card Replacement/Installation ProcedureEach DART Card provides an interface between the SeRF and the Power Amplifier they are spectrum specific. When additional service is needed another DART Card can be added to the HU and the corresponding cover added to a Remote Unit. Individual DART Cards may be replaced without disrupting service to the entire remote system. Only the RF spectrum of the DART Card being removed is affected. Refer to Figure 25.7.5.1 Replacement1. Before working on the HU or handling a DART Card, slip on an Electro-Static Discharge (ESD) wrist strap and connect the ground wire to an earth ground source. Wear the ESD wrist strap while completing each section of the fan installation procedure. 2. Notify the NOC or alarm monitoring system operator that the DART Card is being replaced.3. Disconnect REF IN and OUT cables from the front of the DART Card.4. Loosen the two thumb screws that secure the DART Card to the front of the HU enclosure.5. Carefully withdraw the DART Card from the enclosure. 6. Slide replacement DART Card into the HU chassis until it is firmly seated.7. Secure the DART Card to the front of the enclosure using the two thumb screws loosened in Step 4.8. Connect REF IN and OUT cables to the front of the DART Card.9. Notify the NOC or alarm monitoring system operator that the system is back in operation. Warning:  Electronic components can be damaged by static electrical discharge. To prevent ESD damage, always wear an ESD wrist strap when working on the HU and when handling electronic components.
ADCP-75-348 • Issue 1 • 04/2008Page 34© 2008, ADC Telecommunications, Inc.Figure 25. DART Card Replacement/Installation7.5.2 Install New DART Card1. Before working on the HU or handling a DART Card, slip on an Electro-Static Discharge (ESD) wrist strap and connect the ground wire to an earth ground source. Wear the ESD wrist strap while completing each section of the fan installation procedure. 2. Notify the NOC or alarm monitoring system operator that another DART Card is being added the HU.3. Determine slot location of the new DART Card. Remove blank panel from the front of the HU.4. Slide DART Card into the HU chassis until it is firmly seated.5. Secure the DART Card to the front of the enclosure using the two thumb screws.6. Obtain the required lengths of high performance, flexible, low loss 50-ohm coaxial communications cable (RG-400 or equivalent) for all coaxial connections. 7. Route the forward and reverse path coaxial cables between the HU and the BTS interface (per system design plan) and cut to the required length. Allow sufficient slack for dressing and organizing cables at the HU and for installing an external attenuator in the forward path link. 8. Terminate each cable with an QMA-type male connector following the connector supplier’s recommendations. 9. If required, install an external attenuator in the forward path. Warning:  Electronic components can be damaged by static electrical discharge. To prevent ESD damage, always wear an ESD wrist strap when working on the HU and when handling electronic components. 22401-A
ADCP-75-348 • Issue 1 • 04/2008Page 35© 2008, ADC Telecommunications, Inc.10. Connect the forward path cable to the FWD RF IN connector on the HU DART front panel as shown in Figure 12. 11. Connect the reverse path cable to the REV RF OUT connector on the HU DART front panel (see Figure 12). 12. Dress and secure cables at the right side of the HU. 13. Complete all remaining coaxial connections as specified in the system design plan. 14. Notify the NOC or alarm monitoring system operator that the DART Card is in operation. Note: The composite forward path RF signal level at the HU must be between –25 and +5 dBm. Do not connect the forward path cable until the composite forward path RF signal level is measured and the amount of external attenuation required is determined.
ADCP-75-348 • Issue 1 • 04/2008Page 36© 2008, ADC Telecommunications, Inc.8 CUSTOMER INFORMATION AND ASSISTANCE13944-QContents herein are current as of the date of publication. ADC reserves the right to change the contentswithout prior notice. In no event shall ADC be liable for any damages resulting from loss of data,loss of use, or loss of profits and ADC further disclaims any and all liability for indirect, incidental,special, consequential or other similar damages. This disclaimer of liability applies to all products,publications and services during and after the warranty period.REPRINTS:www.adc.com/manualsPDF copies of manuals are availablefor downloading at the following link:PRODUCT INFORMATION AND TECHNICAL ASSISTANCE:connectivity.tac@adc.comwireless.tac@adc.comeuro.tac@adc.comasiapacific.tac@adc.comADCP Number:WRITE:ADC Telecommunications (S’PORE) PTE, LTD;100 Beach Road, #18-01, Shaw Towers.Singapore 189702.ADC Telecommunications, INCPO Box 1101,Minneapolis, MN 55440-1101, USAADC European Customer Service, INCBelgicastraat 2,1930 Zaventem, BelguimPHONE:U.S.A. or CANADASales:     1-800-366-3891 Extension   73000Technical Assistance:  1-800-366-3891 Connectivity Extension: 73475 Wireless Extension:  73476EUROPESales Administration:  +32-2-712-65 00Technical Assistance:  +32-2-712-65 42EUROPEAN TOLL FREE NUMBERSGermany:   0180 2232923UK:     0800 960236Spain:   900 983291France:   0800 914032Italy:     0800 782374ASIA/PACIFICSales Administration:  +65-6294-9948Technical Assistance:  +65-6393-0739ELSEWHERESales Administration:  +1-952-917-3000Technical Assistance:  +1-952-917-3475 75-348