wbdr part 3

     3 USING EMS FOR   NETWORK TASKS
Element Management System (EMS) 4.0 User Manual27USING EMS FOR NETWORK TASKS                 This section contains instructions for all tasks performed using the Maintenance Interface. Some of these tasks can also be done using the NOC-NEM interface. If so, there is a cross-reference to the NOC-NEM instructions in Section 5. This section also includes instructions for viewing the EMS log file. 3.1 Master List of TasksTable 2 lists all EMS tasks and tells where to look for instructions.Table 2: Master List of EMS TasksYOU CAN SEE TOPICStart EMS. 3.2 on page 28Define EMS ports. 3.3 on page 29Set directory (folder) for EMS program file. 3.4 on page 31Set name, directory, and trim time for EMS log file. 3.5 on page 32Set link timeout, cataloging time, and demo mode. 3.6 on page 34Enter site names and site number for a host/remote pair.  3.7 on page 36Use the alarm overview to view and acknowledge alarms. 3.8 on page 38View alarm detail for a particular host/remote pair. 3.9 on page 42Determine RF signal levels. 3.10 on page 43Enter RF attenuation settings for remote unit antenna. 3.11 on page 44Define RF logical channels and signal gain. 3.12 on page 46Set the host/remote operating mode. 3.13 on page 48Load software from EMS computer to host/remote pair. 3.14 on page 50View the EMS log file. 3.15 on page 53
Starting EMS Section 3Element Management System (EMS) 4.0 User Manual283.2 Starting EMSAfter being installed, EMS has an icon on the desktop. The icon can be used to start EMS.To start EMS1. Double-click on the ADC icon, shown in Figure 13.Figure 13. ADC Icon2. Watch for the DEMS.BAT program to start at the DOS prompt as shown in Figure 14.Figure 14. DEMS.BAT Starting at DOS Command Line3. Watch for the EMS initial screen shown in Figure 15.
Task-Based Reference Defining EMS PortsElement Management System (EMS) 4.0 User Manual29Figure 15. EMS Initial Screen3.3 Defining EMS PortsUsing the Preferences window in EMS, shown in Figure 16, you can define the communication ports to be used by EMS. For a description of the EMS ports, refer to Topic 1.7, Use of Ports, on page 14.To display the Preferences windowSelect EditÞPreferences.To define EMS portsNOTE: EMS default port values may not need to be changed. 1. Check the current setting for two ports in the top left area of the Preferences window (shown in Figure 16):
Defining EMS Ports Section 3Element Management System (EMS) 4.0 User Manual30•EMS/Host/Remote Comm Port—This is the port connected via the ADC-provided RS-232 interface cable to the DB-9 SERVICE port on the host unit front panel. This port provides all components of the Maintenance Interface including the NOC–NEM interface window.•NOC Comm Port—This is an optional second port that can be connected via an RS-232 cable to a direct data link with a remote terminal or with a computer running a terminal emulator program.Figure 16. Preferences Window2. If either of these ports is incorrectly identified:a. Click in the port pull-down menu (port names listed are PC-specific).b. Select the port name causing it to be highlighted as shown in Figure 17.Figure 17. Set Comm Ports DialogWhen done with all entries in the Preferences window, click on OK. For changes to be effective, you have to quit and restart EMS
Task-Based Reference Selecting EMS Program File DirectoryElement Management System (EMS) 4.0 User Manual313.4 Selecting EMS Program File DirectoryUsing the Preferences window in EMS (shown in ". Preferences Window" on page 30), you can select the directory (folder) to be used for host and remote control programs and Field Programmable Gate Arrays (FPGSs).To display the Preferences windowSelect EditÞPreferences.To select the EMS program file directory1. Click in the data entry box for Program File Directory.2. In the window that displays, browse to select the desired folder (causing the folder name to display in the File name field), and click on OK. Figure 18 shows an example.Figure 18. Selecting a Program File DirectoryWhen done with all entries in the Preferences window, click on OK. For changes to be effective, you have to quit and restart EMSNOTE: You cannot use NOC-NEM to select the EMS program file directory.
Defining Log File Name and Trim Time Section 3Element Management System (EMS) 4.0 User Manual323.5 Defining Log File Name and Trim TimeUsing the Preferences window (shown in Figure 16 on page 30), you can perform the following tasks related to the EMS log file:• Select the directory (folder) where the EMS log file is stored.• Change the EMS log file name (EMSlog by default).• Define the trim time.EMS Log File—is a system-created file into which EMS periodically places network status information. This status information includes all parameter values and all alarm states for all NEs currently connected to the system. By default, EMS places new entries into the log file at time intervals of 30 minutes. This time interval can be changed for EMS as a whole, or for any particular NE, using a SET RECORD command in the NOC-NEM window. EMS also writes a status entry into the log file whenever any alarm changes in state (for example, from “no alarm” to “major alarm”). The log file can be viewed using a browser such as Internet Explorer (for more information, refer to Topic 3.15, Viewing the EMS Log File, on page 53).Trim Time—is the number of days that a log file entry remains in the file before it is automatically deleted by the system. When any entry reaches an age in days exceeding the trim time, the entry is deleted. EMS trims the log file once every 24 hours. Maximum trim time allowed is 60 days.NOTE: To avoid losing the entries trimmed from the EMS log file, you should periodically copy and paste the log file into another log folder. To do this, use Windows Explorer copy and paste functions. Save the file with a unique name such as the log file name plus the date on which the file was copied.To display the Preferences windowSelect EditÞPreferences.
Task-Based Reference Defining Log File Name and Trim Element Management System (EMS) 4.0 User Manual33To define the current log file nameNOTE: This does not rename the existing log file, but rather creates a new log file with a new name. The existing file remains with its original name.1. Click on the current name in the Logfile name (.xml) field.2. Key in or browse to select the current log file (see Figure 19).3. Key in the new name in File name field.4. When done, click on OK.Figure 19. New Log File NameTo define the log file trim timeKey in the number of days in the field shown in Figure 20.Figure 20. Defining Trim TimeWhen done with all items in the Preferences window, click on OK. For changes to be effective, you have to quit and restart EMS.
Setting EMS Link Timeout, Cataloging Time, Demo Mode Section 3Element Management System (EMS) 4.0 User Manual34To set the log file time interval using the NOC-NEM interfaceUse the SET RECORD command (see Topic 5.5.10 on page 108).NOTE: You cannot use NOC-NEM to define the log file name or directory.3.6 Setting EMS Link Timeout, Cataloging Time, Demo ModeUsing the Preferences window (shown in Figure 16 on page 30), you can set the following values:•EMS Link Timeout—defines the number of minutes EMS will try to reestablish communication with a network unit before regarding it as “not found.” When this occurs, EMS reports an EMS Link Status alarm.• Cataloging Time—defines the number of seconds, at startup or in response to a ToolsÞRefresh Catalog request, that EMS spends looking for units.•Demo Mode—controls whether EMS operates in demo mode or as a normal working system. Demo mode can only be used when EMS is not connected to a host/remote pair. Demo mode provides a simulated system with two host/remote pairs. NOTE: The Modem Initialization field, which also appears in the Preferences window, is not currently used.To display the Preferences windowSelect EditÞPreferences.To set EMS link timeoutUse the pull-down menu to select from the available times shown in Figure 21.
Task-Based Reference Setting EMS Link Timeout, Cataloging Element Management System (EMS) 4.0 User Manual35Figure 21. Setting EMS Link TimeoutTo Set Cataloging TimeUse the pull-down menu shown in Figure 22 to specify the number of seconds that EMS should look for units on start up or in response to a ToolsÞRefresh Catalog request.Figure 22. Setting Cataloging TimeTo set demo modeIf EMS is not currently connected a host/remote pair, you can start demo mode by selecting Yes from the pull-down menu shown in Figure 23.
Entering Host/Remote Site Numbers and Site Names Section 3Element Management System (EMS) 4.0 User Manual36Figure 23. Selecting Demo ModeWhen done with all entries in the Preferences window, click on OK. For changes to be effective, you have to quit and restart EMSTo set the log file time interval using the NOC-NEM interfaceUse the SET RECORD command (see Topic 5.5.10 on page 108).NOTE: You cannot use NOC-NEM to set the link timeout and cataloging time.3.7 Entering Host/Remote Site Numbers and Site NamesSite number and site name are the basic identifiers for a network element. Eachhost unit must have a unique site number and site name. A remote unit must havea different site name than its own host unit. Host units and remote also each have aunique node number, assigned by the system.To enter a site number or site name for a network element1. Using the View menu, select the menu item identifying the host/remote pair for which you want to enter a site name or site number.NOTE: If the host unit and remote unit have not yet been named, they will be listed on the View menu as NotNamed/NotNamed.2. Click on the host or remote Config tab to display it.3. Click on the Edit button for Site Number or Site Name area within the Con-fig window (see Figure 24).
Task-Based Reference Entering Host/Remote Site Numbers Element Management System (EMS) 4.0 User Manual37Figure 24. Clicking on Edit Button for Site Number4. In the SiteNumber or SiteName dialog (see example in Figure 25), key in the desired site number or site name.5. When done, click on OK.NOTE: Site number can only be entered for a host unit. Site name can be entered for either a host unit or remote unit.Figure 25. Entering a Host Unit Site NumberTo enter a site name using the NOC-NEM interfaceUse the SET SITENAME command (see Topic 5.5.4 on page 99).NOTE: You cannot use NOC-NEM to set the site number.
Using Alarm Overview to View and Acknowledge Alarms Section 3Element Management System (EMS) 4.0 User Manual383.8 Using Alarm Overview to View and Acknowledge AlarmsUsing the AlarmOverview window, shown in Figure 26, you can:• Identify any network element that is currently reporting an alarm.• Determine whether any alarm (currently reported or already cleared) has not been acknowledged.• Acknowledge any as yet unacknowledged alarm.Figure 26. Alarm Overview Example“Acknowledging” an alarm, as an EMS task, is a simple matter of clicking on the appropriate indicator and then on the subsequent dialog. However, as the dialog advises, this process also should involve checking the NOC-NEM scrollout to determine what caused the alarm condition.Alarm status and alarm acknowledgement are reported using two different types of indicators:•ALARM STATUS Indicator—always present in the display, immediately to the right of the host or remote sitename, indicates whether that host or remote is currently reporting any alarm.