4RF N0700AAAA0000A Aprisa XE 700-bbb-vv User Manual Aprisa XE

4RF Limited Aprisa XE 700-bbb-vv Aprisa XE

Contents

User Manual 1

                                April 2012 Version 8.6.77
 |  1  Aprisa XE User Manual  Copyright Copyright © 2012 4RF Limited. All rights reserved. This  document  is  protected  by  copyright  belonging  to  4RF  Limited  and  may  not  be  reproduced  or republished in whole or part in any form without the prior written permission of 4RF Limited.  Trademarks Aprisa and the 4RF logo are trademarks of 4RF Limited.  Windows is a registered trademark of Microsoft Corporation in the United States and other countries. Java and all Java-related trademarks are trademarks or registered trademarks of Sun Microsystems, Inc. in the United States and other countries. All other marks are the property of their respective owners. GoAhead WebServer. Copyright © 2000 GoAhead Software, Inc. All Rights Reserved. Disclaimer Although every precaution has been taken preparing this information, 4RF Limited assumes no liability for errors  and  omissions,  or  any  damages  resulting  from  use  of  this  information.  This  document  or  the equipment may change, without notice, in the interests of improving the product. RoHS and WEEE Compliance The Aprisa XE is fully compliant with the European Commission’s RoHS (Restriction of Certain Hazardous Substances in Electrical and Electronic Equipment) and WEEE (Waste Electrical and Electronic Equipment) environmental directives.  Restriction of hazardous substances (RoHS) The  RoHS Directive  prohibits  the  sale  in  the  European  Union  of  electronic  equipment  containing  these hazardous substances: lead*, cadmium, mercury, hexavalent chromium, polybrominated biphenyls (PBBs), and polybrominated diphenyl ethers (PBDEs). 4RF Limited has worked with its component suppliers to ensure compliance with the RoHS Directive which came into effect on the 1st July 2006.  *The European Commission Technical Adaptation Committee (TAC) has exempted lead in solder for high-reliability applications for which viable lead-free alternatives have not yet been identified. The exemption covers  communications  network  infrastructure  equipment,  which  includes  4RF  Limited  Aprisa  XE microwave radios.  End-of-life recycling programme (WEEE) The WEEE Directive concerns the recovery, reuse, and recycling of electronic  and electrical equipment. Under the Directive, used equipment must be marked, collected separately, and disposed of properly. 4RF  Limited  has  instigated  a  programme  to  manage  the  reuse,  recycling,  and  recovery  of  waste  in  an environmentally safe manner using processes that comply with the WEEE Directive (EU Waste Electrical and Electronic Equipment 2002/96/EC). 4RF  Limited  invites  questions  from  customers  and  partners  on  its  environmental  programmes  and compliance with the European Commission’s Directives (sales@4RF.com).
2  |     Aprisa XE User Manual  Compliance General The Aprisa XE digital radio predominantly operates within frequency bands that require a site license be issued  by  the  radio  regulatory  authority  with  jurisdiction  over  the  territory  in  which  the  equipment  is being operated. It  is the responsibility of the user, before operating the  equipment, to ensure that where  required the appropriate license has been granted and all conditions attendant to that license have been met. Changes  or  modifications  not  approved  by  the  party  responsible  for  compliance  could  void  the  user’s authority to operate the equipment. Equipment  authorizations  sought  by  4RF  Limited  are  based  on  the  Aprisa  XE  radio  equipment  being installed at a fixed location and operated in a continuous point-to-point mode within the environmental profile  defined  by  EN 300 019,  Class 3.2.  Operation  outside  these  criteria  may  invalidate  the authorizations and / or license conditions. The term ‘Terminal’ with reference to the Aprisa XE User Manual, is a generic term for one end of a fixed point-to-point Aprisa XE link and does not confer any rights to connect to any public network or to operate the equipment within any territory. Compliance ETSI The  Aprisa  XE  radio  terminal  is  designed  to  comply  with  the  European  Telecommunications  Standards Institute (ETSI) specifications as follows:  Radio performance EN 302 217 Parts 1, 2.1, and 2.2 EMC EN 301 489 Parts 1 & 4 Environmental EN 300 019, Class 3.2 Safety EN 60950   An Aprisa XE radio terminal operating in the following frequency bands / channel sizes has been tested and is compliant to the ETSI radio specifications and suitably displays the CE logo. Other bands are compliant to the same radio performance specifications as adapted by 4RF  Limited  and  therefore  may  be  used  in  regions  where  compliance  requirements demand CE performance at other frequencies.  Frequency band Channel size Power input Notified body 300 MHz 400 MHz 25 kHz, 50 kHz, 75 kHz, 125 kHz, 150 kHz, 250 kHz, 500 kHz, 1.0 MHz, 1.75 MHz, 3.50 MHz 12 VDC, 24 VDC, 48 VDC, 115/230 VAC Notified Body 0678 600 MHz 700 MHz 800 MHz 900 MHz 500 kHz 12 VDC, 24 VDC, 48 VDC, 115/230 VAC Notified Body 0678 1400 MHz 75 kHz, 150 kHz, 250 kHz, 500 kHz, 1.0 MHz, 1.75 MHz, 3.50 MHz, 7 MHz 12 VDC, 12 VDC LP, 24 VDC, 48 VDC, 115/230 VAC  1800 MHz 2000 MHz 2500 MHz 250 kHz, 500 kHz, 1.0 MHz, 1.75 MHz, 3.50 MHz, 7 MHz, 14 MHz 12 VDC, 24 VDC, 48 VDC, 115/230 VAC
 |  3  Aprisa XE User Manual  Informal Declaration of Conformity  Dansk Undertegnede 4RF Limited erklærer herved, at følgende udstyr Aprisa Radio overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF. Deutsch Hiermit erklärt 4RF Limited, dass sich dieses Aprisa Radio in Übereinstimmung mit  den  grundlegenden  Anforderungen  und  den  anderen  relevanten Vorschriften der Richtlinie 1999/5/EG befindet. (BMWi) Dutch Hierbij  verklaart  4RF  Limited  dat  het  toestel  Aprisa  Radio  in overeenstemming  is  met  de  essentiële  eisen  en  de  andere  relevante bepalingen van richtlijn 1999/5/EG. English Hereby,  4RF  Limited,  declares  that  this  Aprisa  Radio  equipment  is  in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Español Por medio de la presente 4RF Limited declara que el Aprisa Radio cumple con los  requisitos  esenciales  y  cualesquiera  otras  disposiciones  aplicables  o exigibles de la Directiva 1999/5/CE. ΢λληνας ΜΕ  ΣΗΝ  ΠΑΡΟΤ΢Α  4RF  Limited  ΔΗΛΩΝΕΙ  ΟΣΙ  Aprisa  Radio  ΢ΤΜΜΟΡΥΩΝΣΑΙ ΠΡΟ΢  ΣΙ΢  ΟΤ΢ΙΩΔΕΙ΢  ΑΠΑΙΣΗ΢ΕΙ΢  ΚΑΙ  ΣΙ΢  ΔΟΙΠΕ΢  ΢ΦΕΣΙΚΕ΢  ΔΙΑΣΑΞΕΙ΢  ΣΗ΢ ΟΣΗΓΙΑ΢ 1995/5/ΚΕ. Français Par la présente 4RF Limited déclare que l'appareil Aprisa Radio est conformé aux  exigences  essentielles  et  aux  autres  dispositions  pertinentes  de  la directive 1999/5/CE. Italiano Con la presente 4RF Limited dichiara che questo Aprisa Radio è conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE. Português 4RF Limited  declara que este Aprisa Radio  está conforme com os  requisitos essenciais e outras provisões da Directiva 1999/5/CE. Suomalainen  4RF Limited vakuuttaa täten että Aprisa Radio tyyppinen laite on direktiivin 1999/5/EY  oleellisten  vaatimusten  ja  sitä  koskevien  direktiivin  muiden ehtojen mukainen. Svensk  Härmed intygar 4RF Limited att denna Aprisa Radio står I överensstämmelse med  de  väsentliga  egenskapskrav  och  övriga  relevanta  bestämmelser  som framgår av direktiv 1999/5/EG. A formal Declaration of Conformity document is shipped with each Aprisa XE terminal.
4  |     Aprisa XE User Manual  Compliance FCC The Aprisa XE radio terminal is designed to comply with the Federal Communications Commission  (FCC) specifications as follows:  Radio performance / EMC (dependant on variant) 47CFR part 90 Private Land Mobile Radio Services 47CFR part 101 Fixed Microwave Services 47CFR part 27 Misc Wireless Communication Services 47CFR part 15 Radio Frequency Devices Safety EN 60950  Frequency band limits Channel size Power input Authorization FCC ID 421 MHz to 512 MHz 25 kHz 48 VDC Part 90 Certification UIPN0400025A0200A 932.5 MHz to 944 MHz 100 kHz, 200 kHz 24 VDC, 48 VDC, 110 VAC Part 101 Verification - 2314.5 MHz to 2317.5 MHz 2346.5 MHz to 2349.5 MHz 250 kHz, 500 kHz 24 VDC, 48 VDC, 110 VAC Part 27 Certification UIPN2500AAAA0200A  NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful  interference  when  the  equipment  is  operated  in  a  commercial  environment.  This  equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the  instruction  manual,  may  cause  harmful  interference  to  radio  communications.  Operation  of  this equipment  in  a  residential  area  is  likely  to  cause  harmful  interference  in  which  case  the  user  will  be required to correct the interference at his own expense.  Compliance Industry Canada The Aprisa XE radio terminal is designed to comply with Industry Canada (IC) specifications as follows:  Radio performance (dependant on variant) RSS-GEN RSS-119 EMC This Class A digital apparatus complies with Canadian standard ICES-003 Safety EN 60950  Frequency band limits Channel size Power input Authorization IC ID 932.5 MHz to 944 MHz 100 kHz, 200 kHz 24 VDC, 48 VDC, 110 VAC RSS-119 6772A-N09AAACC 406.1 MHz to 430 MHz 450 MHz to 470 MHz 25 kHz, 75 kHz, 150 kHz 12 VDC 24 VDC, 48 VDC, 110 VAC RSS-119 6772A-N04AAAEC
 |  5  Aprisa XE User Manual  RF Exposure Warning   WARNING: The installer and / or user of Aprisa XE radio terminals shall ensure that a separation distance as given in the following table is maintained between the main axis of the terminal’s antenna and the body of the user or nearby persons. Minimum  separation  distances  given  are  based  on  the  maximum  values  of  the following methodologies: 1. Maximum Permissible Exposure non-occupational limit (B or general public) of 47 CFR 1.1310 and the methodology of FCC’s OST/OET Bulletin number 65.  2.  Reference levels as given in Annex III, European Directive on the limitation of exposure  of  the  general  public  to  electromagnetic  fields  (0 Hz  to  300 GHz) (1999/519/EC).  These  distances  will  ensure  indirect  compliance  with  the requirements of EN 50385:2002.    Frequency (MHz) Maximum power (dBm) Maximum antenna gain (dBi) Maximum power density (mW/cm2) Minimum separation distance (m) 400 + 35 15 0.20 2.0 512 + 35 15 0.26 1.8 715 + 34 15 0.36 1.3 806 + 34 28 0.40 5.6 890 + 34 28 0.45 5.3 960 + 34 28 0.48 5.1 1550 + 34 33 0.78 7.2 2300 + 34 37 1.00 10.0 2700 + 34 38 1.00 11.2
 Contents  |  7  Aprisa XE User Manual  Contents  1. Getting Started .......................................................................... 15 2. Introduction .............................................................................. 19 About This Manual ............................................................................... 19 What It Covers ............................................................................ 19 Who Should Read It ...................................................................... 19 Contact Us ................................................................................. 19 What's in the Box ................................................................................ 19 Aprisa XE CD Contents ................................................................... 20 Accessory Kit .............................................................................. 21 3. Preparation............................................................................... 23 Path Planning .................................................................................... 23 Antenna Selection and Siting ........................................................... 23 Coaxial Feeder Cables ................................................................... 26 Link Budget ................................................................................ 26 Site Requirements ............................................................................... 27 Power Supply .............................................................................. 27 Equipment Cooling ....................................................................... 27 Earthing and Lightning Protection ..................................................... 28 4. About the Terminal..................................................................... 29 Introduction ...................................................................................... 29 Modules ........................................................................................... 30 Front Panel Connections and Indicators ..................................................... 31 Interface Card Types............................................................................ 32 5. Mounting and Installing the Terminal .............................................. 33 Required Tools ................................................................................... 33 Installing the Terminal ......................................................................... 33 Installing the Antenna and Feeder Cable .................................................... 34 External Alarms .................................................................................. 35 Alarm Circuit Setup ...................................................................... 35 Interface Cabling ................................................................................ 36 Power Supplies................................................................................... 37 DC Power Supply.......................................................................... 37 AC Power Supply .......................................................................... 40 Safety Earth ............................................................................... 42 Bench Setup ...................................................................................... 43
8  |  Contents   Aprisa XE User Manual  6. Connecting to the Terminal .......................................................... 45 Connecting to the Terminal's Setup Port .................................................... 45 Connecting to the Terminal's Ethernet Interface ........................................... 48 PC Requirements for SuperVisor ....................................................... 49 PC Settings for SuperVisor .............................................................. 50 IP Addressing of Terminals ..................................................................... 53 Network IP Addressing .......................................................................... 54 Same Subnet as the Local PC ........................................................... 54 Different Subnet as the Local PC ...................................................... 55 7. Managing the Terminal ................................................................ 57 The Setup Menu ................................................................................. 57 SuperVisor ........................................................................................ 59 SuperVisor Logging In .................................................................... 60 SuperVisor Logging Out .................................................................. 61 SuperVisor Main Screen ......................................................................... 62 Changing the Terminal’s IP Address .......................................................... 64 Setting Up Users ................................................................................. 65 User groups ................................................................................ 65 Adding a User ............................................................................. 65 Disabling a User........................................................................... 66 Deleting a User ........................................................................... 66 Saving User Information ................................................................. 66 Changing Passwords ...................................................................... 67 Viewing User Session Details ............................................................ 67 8. Configuring the Terminal ............................................................. 69 Configuring the RF Settings .................................................................... 69 Modem Performance Settings........................................................... 72 Entering Basic Terminal Information ......................................................... 74 Configuring the IP Settings ..................................................................... 75 Setting the Terminal Clocking ................................................................. 76 Setting the Duplexer Parameters ............................................................. 79 Setting the RSSI Alarm Threshold ............................................................. 80 Configuring the External Alarms .............................................................. 81 Configuring the External Alarm Inputs ................................................ 81 Configuring the External Alarm Outputs .............................................. 83 Configuring SNMP Settings ..................................................................... 85 SNMP Access Controls .................................................................... 86 SNMP Trap Destinations ................................................................. 87 Viewing the SNMP Traps ................................................................. 88 Viewing the SNMP MIB Details .......................................................... 88 Saving the Terminal's Configuration .......................................................... 89
 Contents  |  9  Aprisa XE User Manual  9. Configuring the Traffic Interfaces .................................................. 91 Viewing a Summary of the Interfaces ........................................................ 91 Configuring the Traffic Interfaces ............................................................ 92 Ethernet Switch ................................................................................. 93 VLAN tagging .............................................................................. 93 Quality of Service ........................................................................ 96 Viewing the Status of the Ethernet Ports ........................................... 100 Resetting the Ethernet Settings ...................................................... 100 Ethernet Port Startup .................................................................. 101 QJET Port Settings ............................................................................ 102 Q4EM Port Settings ............................................................................ 104 Loop Interface Circuits ....................................................................... 107 DFXO / DFXS Loop Interface Circuits ................................................ 107 E1 CAS to DFXS Circuits ................................................................ 110 DFXS to DFXS Hotline Circuits ........................................................ 110 DFXS Port Settings ...................................................................... 112 DFXO Port Settings ..................................................................... 120 QV24 Serial Interface Card ................................................................... 128 QV24 Port Settings ..................................................................... 129 QV24S Port Settings .................................................................... 130 HSS Port Settings .............................................................................. 133 HSS Handshaking and Clocking Modes ...................................................... 135 HSS Handshaking and Control Line Function ....................................... 135 HSS Synchronous Clock Selection Modes ............................................ 138
10  |  Contents   Aprisa XE User Manual  10. Cross Connections ..................................................................... 145 Embedded Cross Connect Switch............................................................ 145 Link Capacity Utilization .............................................................. 145 The Cross Connections Application ......................................................... 145 The Cross Connections System Requirements ...................................... 145 Installing the Cross Connections Application ....................................... 146 Opening the Cross Connections Application ........................................ 146 The Cross Connections Page .......................................................... 147 Setting the Terminal's IP Address .................................................... 149 Management and User Ethernet Capacity........................................... 150 Setting Card Types ..................................................................... 151 Getting Cross Connection Configuration from the Terminals .................... 151 Creating Cross Connections ........................................................... 152 Sending Cross Connection Configuration to the Terminals ....................... 155 Saving Cross Connection Configurations ............................................ 155 Using Existing Cross Connection Configurations ................................... 155 Printing the Cross Connection Configuration ....................................... 156 Deleting Cross Connections ........................................................... 157 Configuring the Traffic Cross Connections ................................................. 158 Compatible Interfaces ................................................................. 158 QJET Cross Connections ............................................................... 159 Selecting and Mapping Bits and Timeslots .......................................... 166 Q4EM Cross Connections ............................................................... 170 DFXS and DFXO Cross Connections ................................................... 171 QV24 Cross Connections ............................................................... 172 QV24S Cross Connections .............................................................. 173 HSS Cross Connections ................................................................. 174 Cross Connection Example ................................................................... 175 Symmetrical Connection Wizard ............................................................ 176 Starting the Cross Connections Wizard .............................................. 176 Cross Connections Wizard Navigation ............................................... 176 Setting the Cross Connections IP Address ........................................... 177 Setting the Cross Connections Bandwidth .......................................... 177 Cross Connections Card Selection .................................................... 178 Cross Connections Interface Configurations ........................................ 179 Symmetrical Connection Summary................................................... 180 Send Symmetrical Connection Configuration ....................................... 180 11. Protected Terminals .................................................................. 181 Monitored Hot Stand By (MHSB) ............................................................. 181 Tributary Switch Front Panel ......................................................... 182 RF Switch Front Panel ................................................................. 183 MHSB Cabling............................................................................ 185 MHSB Power Supply .................................................................... 185 Configuring the Radios for Protected Mode ........................................ 186 Hitless Space Diversity (HSD) ................................................................ 190 HSD Terminal Cabling .................................................................. 191 HSD Terminal IP Addresses ............................................................ 192
 Contents  |  11  Aprisa XE User Manual  12. In-Service Commissioning ............................................................ 197 Before You Start ............................................................................... 197 What You Will Need .................................................................... 197 Applying Power to the Terminals ........................................................... 198 Review the Link Configurations Using SuperVisor ........................................ 198 Antenna Alignment ............................................................................ 199 Checking the Antenna Polarization .................................................. 199 Visually Aligning Antennas ............................................................ 200 Accurately Aligning the Antennas .................................................... 201 Checking Performance ................................................................. 203 Checking the Receive Input Level .................................................... 203 Checking the Fade Margin ............................................................. 204 Checking the Long-Term BER ......................................................... 205 Bit Error Rate Tests .................................................................... 205 Additional Tests ........................................................................ 206 Checking the Link Performance ...................................................... 207 Viewing a Summary of the Link Performance ...................................... 208 Saving the History of the Link Performance ........................................ 209 13. Maintenance ............................................................................ 213 Routine Maintenance ......................................................................... 213 Terminal Upgrades ............................................................................ 214 Software Upgrade Process ............................................................ 215 Uploading the Root File System ...................................................... 216 Uploading the Motherboard Images .................................................. 216 Identifying the Correct TFTP Upgrade Type ........................................ 217 TFTP Upgrade Process Types ......................................................... 220 Uploading System Files ................................................................ 226 Viewing the Image Table .............................................................. 231 Changing the Status of an Image File................................................ 232 Rebooting the Terminal ...................................................................... 233 Support Summary.............................................................................. 234 Installing Interface Cards .................................................................... 235 Preparing the Terminal for New Interface Cards .................................. 236 Installing an Interface Card ........................................................... 238 Configuring a Slot ...................................................................... 240 14. Troubleshooting ........................................................................ 241 Loopbacks ...................................................................................... 241 RF Radio Loopback ..................................................................... 241 Interface Loopbacks ................................................................... 242 Timeslot Loopbacks .................................................................... 243 Alarms........................................................................................... 244 Diagnosing Alarms ...................................................................... 244 Viewing the Alarm History ............................................................ 246 Saving the Alarm History .............................................................. 247 Viewing Interface Alarms.............................................................. 248 Clearing Alarms ......................................................................... 249 Identifying Causes of Alarms .......................................................... 250 E1 / T1 Alarm Conditions.............................................................. 252 System Log ..................................................................................... 253 Checking the Syslog .................................................................... 253 Setting up for Remote Logging ....................................................... 255
12  |  Contents   Aprisa XE User Manual  15. Interface Connections ................................................................ 257 RJ-45 Connector Pin Assignments ........................................................... 257 Interface Traffic Direction ................................................................... 257 QJET Interface Connections ................................................................. 258 Ethernet Interface Connections ............................................................. 259 Q4EM Interface Connections ................................................................. 260 E&M Signalling Types .................................................................. 261 DFXS Interface Connections.................................................................. 263 DFXO Interface Connections ................................................................. 264 HSS Interface Connections ................................................................... 265 Synchronous cable assemblies ........................................................ 266 Cable WAN Connectors ................................................................ 272 QV24 Interface connections ................................................................. 273 QV24S Interface connections ................................................................ 273 16. Alarm Types and Sources ............................................................ 275 Alarm Types .................................................................................... 275 Transmitter Alarms..................................................................... 275 Receiver Alarms ........................................................................ 277 MUX Alarms .............................................................................. 280 Modem Alarms .......................................................................... 280 Motherboard Alarms ................................................................... 280 QJET Alarms ............................................................................. 281 DFXO Alarms ............................................................................ 281 DFXS Alarms ............................................................................. 281 HSS Alarms .............................................................................. 282 QV24 Alarms............................................................................. 282 External Alarm Inputs .................................................................. 282 Remote Terminal Alarms .............................................................. 282 Cross Connect Alarms .................................................................. 283 MHSB Alarms ............................................................................ 283 HSD Alarms .............................................................................. 283 Software Alarms ........................................................................ 284 17. Country Specific Settings ............................................................ 285
 Contents  |  13  Aprisa XE User Manual  18. Specifications ........................................................................... 287 RF Specifications .............................................................................. 287 ETSI ....................................................................................... 287 FCC ....................................................................................... 294 Industry Canada ........................................................................ 297 Receiver Performance ................................................................. 301 Duplexers ................................................................................ 301 Interface Specifications ...................................................................... 302 Ethernet Interface ..................................................................... 302 QJET Quad E1 / T1 Interface ......................................................... 303 Q4EM Quad 4 Wire E&M Interface .................................................... 304 DFXO Dual Foreign Exchange Office Interface ..................................... 305 DFXS Dual Foreign Exchange Subscriber Interface ................................. 307 QV24 Quad V.24 Serial Data Interface .............................................. 309 QV24S Quad V.24 Serial Data Interface ............................................. 309 HSS Single High Speed Synchronous Data Interface ............................... 310 External Alarm Interfaces ............................................................. 310 Auxiliary Interfaces .................................................................... 310 Power Specifications .......................................................................... 311 AC Power Supply ........................................................................ 311 DC Power Supply........................................................................ 311 Power Consumption .................................................................... 312 Protection System Specifications ........................................................... 314 MHSB Protection ........................................................................ 314 HSD Protection .......................................................................... 314 General Specifications ........................................................................ 315 Environmental .......................................................................... 315 Mechanical .............................................................................. 315 ETSI Compliance ........................................................................ 315 19. Product End Of Life ................................................................... 317 End-of-Life Recycling Programme (WEEE) ................................................. 317 The WEEE Symbol Explained .......................................................... 317 WEEE Must Be Collected Separately ................................................. 317 YOUR ROLE in the Recovery of WEEE ................................................ 317 EEE Waste Impacts the Environment and Health .................................. 317 20. Abbreviations ........................................................................... 319 21. Acknowledgments and Licensing ................................................... 321 22. Commissioning Form .................................................................. 327 23. Index ...................................................................................... 329
 Getting Started  |  15  Aprisa XE User Manual  1. Getting Started This section is an overview of the steps required to commission a link in the field.  Phase 1: Pre-installation  1. Confirm path planning. Page  23   2. Ensure that the site preparation is complete:  Power requirements  Tower requirements  Environmental considerations, for example, temperature control  Rack space Page  26  3. Confirm the interface card configuration.    Phase 2: Installing the terminals  1. Before installing the terminal into the rack, check that all the required interface cards are fitted.    Position and mount the terminal in the rack. Page  33  2. Connect earthing to the terminal. Page  28  3. Confirm that the:  Antenna is mounted and visually aligned.  Feeder cable is connected to the antenna.  Feeder connections are tightened to recommended level.  Tower earthing is complete.   4. Install lightning protection. Page  28  5. Connect the coaxial jumper cable between the lightning protection and the terminal duplexer.   6. Connect the power supply to the terminal and apply power. Page  35
16  |  Getting Started   Aprisa XE User Manual   Phase 3: Establishing the link  1. If you don't know the terminal's IP address : Connect the setup cable between the terminal's Setup port and the PC using accessory kit adaptor.  Use HyperTerminal to confirm the IP settings for the terminal:  Local IP address  Local subnet mask  Remote terminal IP address Reboot the terminal Page  58  2. Connect  the  Ethernet  cable  between  the  terminal's  4-port  Ethernet switch and the PC.   3. Confirm  that  the  PC  IP  settings  are  correct  for  the  4-port  Ethernet switch:  IP address  subnet mask Page  50  4. Confirm that Java is installed on the PC. Page  49  5. Start the web browser, and log into the terminal. Page  60  6. Set or confirm the RF characteristics:  TX and RX frequencies  Modulation type  TX output power Page  69  7. Compare  the  actual  RSSI  to  the  expected  RSSI  value  (from  your  path planning).   8. Fine-align the antennas. Page  201  9. Confirm that the terminal clock sources are set correctly. Page  73  10. Confirm that the TX and RX LEDs are green. Disregard the OK LED status for now.
 Getting Started  |  17  Aprisa XE User Manual   Phase 4: Configuring the traffic   1. Confirm  that  the  interface  hardware  and  software  slot  configurations match.   2. Confirm the interface card settings. Page  92  3. Open  the  Cross  Connections  application  and  configure  the  cross connections:  Download the configuration.  Confirm or modify the traffic cross connections.  Save the configuration to the terminal.  Activate the configuration. Page  146  4. Save  the  configuration  to  disk  and  close  the  Cross  Connections application. Page  155  5. Connect the connection of interface cables.   6. Confirm or adjust the terminal clocking for network synchronization, if required.   7. Test that the traffic is passing over the link as configured.   8. Confirm or configure the external alarm settings in SuperVisor. Page  81  9. Setup an external alarm connection cable, if required.   10. Reset any alarms and error counters. Page  244  11. Perform traffic pre-commissioning tests (optional)   12. Complete the commissioning form (at the back of the manual) and file. Page  327
 Introduction  |  19  Aprisa XE User Manual  2. Introduction About This Manual What It Covers This user manual describes how to install and configure Aprisa XE fixed point-to-point digital radio links. It specifically documents an Aprisa XE terminal running system software version 8.6.77. It is recommended that you read the relevant sections of this manual before installing or operating the terminal.  Who Should Read It This manual has  been written for professional field technicians and engineers who have an  appropriate level of education and experience.  Contact Us If  you  experience  any  difficulty  installing  or  using  Aprisa  XE  after  reading  this  manual,  please  contact Customer Support or your local 4RF representative.  Our area representative contact details are available from our website:  4RF Limited 26 Glover Street, Ngauranga PO Box 13-506 Wellington 6032 New Zealand  E-mail support@4rf.com Web site www.4rf.com Telephone +64 4 499 6000 Facsimile +64 4 473 4447 Attention Customer Services  What's in the Box Inside the box you will find:   Aprisa XE terminal  Accessory kit  Aprisa CD  Aprisa XE Quick Start Guide  Commissioning Form  Configuration sheet
20  |  Introduction   Aprisa XE User Manual  Aprisa XE CD Contents The Aprisa XE CD contains the following: Software  The latest version of the terminal software (see ‘Terminal Upgrades’ on page 214)  The Cross Connections application - required if you want to use the Cross Connections application offline (see ‘Installing Cross Connections application’ on page 146).  Java VM - Java plug-in needed to run the Supervisor software.  Web browsers - Mozilla Firefox and Internet Explorer are included for your convenience.  Adobe™ Acrobat® Reader® which you need to view the PDF files on the Aprisa CD.  Documentation  User manual — an electronic (PDF) version for you to view online or print.  Product collateral —  application overviews, product description, quick start guide, case  studies, software release notes and white papers.  Tools  Surveyor - a path propagation calculator developed by 4RF (see ‘Path planning’ on page 23).  XEpower – a power consumption model program.
 Introduction  |  21  Aprisa XE User Manual  Accessory Kit The accessory kit contains the following items:  Two mounting brackets and screws  Two interface slot blanking plates  Setup cable (RJ-45 to RJ-45)  2 m and RS-232 DB9 female adaptor  Hardware kit (includes Allen key for fascia screws)
22  |  Introduction   Aprisa XE User Manual  Alarm cable (RJ-45 to RJ-45) 5 m  Ground cable 5 m  DC power cable 3 m (for use with the ±48 VDC, ±24 and 12 VDC low power power supplies)  AC power cable 2 m (for use with the 110 / 230 VAC power supply)
 Preparation  |  23  Aprisa XE User Manual  3. Preparation Path Planning Proper path planning is essential.  When considering the components of your radio system, think about:  antenna selection and siting  coaxial cable selection  link budget You can also use Surveyor to help you with path feasibility planning. Surveyor is a path propagation calculator developed by 4RF to assist path planners quickly and efficiently verify the viability of point-to-point transmission links deploying the Aprisa microwave radio systems. The software program calculates the anticipated link performance for the transmission system elements you have selected. However, it is not a substitute for in-depth path planning. You will find Surveyor a valuable addition to your planning toolbox. A copy of Surveyor is provided on the Aprisa CD supplied with this manual. You can download updates from www.4rf.com.  Antenna Selection and Siting Selecting and siting antennas are important considerations in your system design. There are three main types of directional antenna that are commonly used with the radios parabolic grid, Yagi and corner reflector antennas. The antenna that should be used  for a particular situation is determined  primarily by the frequency of operation and the gain required to establish a reliable link. Parabolic Grid Antennas   Factor Explanation Frequency Often used in 1350-2700 MHz bands Gain Varies with size (17 dBi to 30 dBi typical) Wind loading Can be significant Tower aperture required Can be significant Size Range from 0.6 m to 3 m diameter Front to back ratio Good Cost High
24  |  Preparation   Aprisa XE User Manual  Yagi Antennas   Factor Explanation Frequency Often used in 330-960 MHz bands Gain Varies with size (typically 11 dBi to 16 dBi) Stackable gain increase 2 Yagi antennas (+ 2.8 dB) 4 Yagi antennas (+ 5.6 dB) Wind loading Less than a parabolic grid antenna Tower aperture required Unstacked: Less than a parabolic grid antenna Stacked: about the same as a parabolic grid antenna Size Range from 0.6 m to 3 m in length Front to back ratio Low Cost Low  It is possible to increase the gain of a Yagi antenna installation by placing two or more of them in a stack. The relative position of the antennas is critical.   Example of stacked antennas
 Preparation  |  25  Aprisa XE User Manual  Corner Reflector Antennas    Factor Explanation Frequency Often used in 330-960 MHz bands Gain Typically 10 dBd Wind loading Less than a parabolic grid antenna Tower aperture required About the same as a parabolic grid antenna Size Range from 0.36 m to 0.75 m in length Front to back ratio High (typically 30 dB) Beamwidth Broad (up to 60°) Cost Medium  Antenna Siting When siting antennas, consider the following points:  A site with a clear line of sight to the remote terminal is needed. Pay particular attention to trees, buildings, and other obstructions close to the antenna site.  Example of a clear line-of-sight path  Any  large  flat  areas  that  reflect  RF  energy  along  the  link  path,  for  instance,  water,  could  cause multipath fading. If the link  path crosses a feature that  is likely to cause RF reflections, shield the antenna  from  the  reflected  signals  by  positioning  it  on  the  far  side  of  the  roof  of  the  equipment shelter or other structure.  Example of a mid-path reflection path  The antenna site should be as far as possible from other potential sources of RF interference such as electrical equipment, power lines and roads.  The antenna site should be as close as possible to the equipment shelter.  Note:  Wide  angle  and  zoom  photographs  taken  at  the  proposed  antenna  location  (looking  down  the proposed path), can be useful when considering the best mounting positions.
26  |  Preparation   Aprisa XE User Manual  Coaxial Feeder Cables To ensure maximum performance, it is recommended that you use good quality low-loss coaxial cable for all feeder runs. For installations requiring long antenna cable runs, use Andrew Heliax™ or equivalent. When  using  large  diameter  feeders,  use  a  short  flexible  jumper  cable  between  the  feeder  and  the terminal to reduce stress on the antenna port connector. All coaxial cable has loss, that is, the RF energy traveling through it is attenuated. Generally speaking, the larger the diameter of the cable, the less the loss. When selecting a coaxial cable consider the following:  Factor Effect Attenuation Short cables and larger diameter cables have less attenuation Cost Smaller diameter cables are cheaper Ease of installation Easier with smaller diameter cables or short cables  When running cables:  Run coaxial cable from the installation to the antenna, ensuring you leave enough extra cable at each end to allow drip loops to be formed.  For 19-inch rack mount installations, cables may be run from the front of the rack directly onto the antenna port. They may also be run through the back of the rack to the front.  Terminate and earth or ground the cables in accordance with the manufacturers'  instructions. Bond the outer conductor of the coaxial feeder cables to the base of the tower mast.  Link Budget All of the above factors (and many others not mentioned) combine in any proposed installation to create a link budget. The link budget predicts how well the radio link will perform after it is installed. Use  the outputs of  the  link  budget  during  commissioning testing  to confirm the link has  been  installed correctly, and that it will provide reliable service.
 Preparation  |  27  Aprisa XE User Manual  Site Requirements Power Supply Ensure that the correct power supply is available for powering the terminal. The nominal input voltage for a terminal is 12, 24 or 48 volts DC or 115 / 230 volts AC rms. The DC supply voltage is factory preset at time of order and cannot be adjusted in the field. The terminal voltage is indicated on the chassis label by the DC input connector and on the specification label fitted to the terminal.   WARNING: Before connecting power, ground the chassis using the safety earth terminal on the front panel.   Equipment Cooling Mount  the  terminal  so  that  air  can  flow  through  it.  Do  not  obstruct  the  free  flow  of  air  around  the terminal. The two internal, speed-controlled fans fitted into the chassis provide sufficient cooling. The operation of the fans is monitored and an alarm is raised under failure conditions. The environmental operating conditions are as follows:  Operating temperature -10°C to +50°C Storage temperature -20°C to +70°C Humidity Maximum 95% non-condensing
28  |  Preparation   Aprisa XE User Manual  Earthing and Lightning Protection    WARNING: Lightning can easily damage electronic equipment. To avoid this risk, install primary lightning protection devices on any interfaces that are reticulated in the local cable network. You should also install a coaxial surge suppressor on the antenna port of the duplexer.   Earth  the  antenna  tower,  feeders  and  lightning  protection  devices  in  accordance  with  the  appropriate local and national standards. The diagram below shows the minimum requirements. Use grounding kits as specified or supplied by the coaxial cable manufacturer to properly ground or bond the cable outer.
 About the Terminal  |  29  Aprisa XE User Manual  4. About the Terminal Introduction The terminals  operate  in  a number of frequency bands  from 300 MHz up to 2.7 GHz carrying ethernet, voice and data traffic over distances up to 100 kilometres. They are designed to meet the demands of a wide range of low to medium capacity access and backhaul applications. The digital access terminal is a compact, powerful point-to-point linking solution with up to 64 Mbit/s of radio link capacity, and customer-configurable interface options integrated within the radio platform.
30  |  About the Terminal   Aprisa XE User Manual  Modules The terminal is modular in design, which helps reduce mean time to repair (MTTR). It is designed for 19-inch rack mounting and is only 2U high for standard configurations. The five main modules housed inside the chassis are the transceiver, modem, motherboard, power supply, and duplexer. Interface  cards are fitted into the eight interface slots on the motherboard. Modules  are interconnected via several buses on the motherboard. A duplexer can be mounted inside or outside the chassis.   The interrelationships between the components are shown below:
 About the Terminal  |  31  Aprisa XE User Manual  Front Panel Connections and Indicators    All connections to the terminal are made on the front panel of the terminal.  No. Label Description 1 AC or DC power input DC and AC power supplies are available (AC is shown) 2 Safety earth stud An M5 stud for connection to an external protection ground for protection against electric shock in case of a fault. 3 Antenna connector N-type 50Ω female connector for connection of antenna feeder cable. 4 Interface slots A to H Eight interface slots on the motherboard to fit interface cards. 5 ETHERNET Integrated four-port layer 2 switch. 6 SETUP RJ-45 serial connection to PC for initial configuration. 7 ALARM RJ-45 connector for two external alarm input and four external alarm output connections. 8 LED indicators   OK Indicates normal operation and minor and major alarm conditions.  RX Indicates status of receive path including normal operation and alarms such as BER, RSSI and loss of synchronization.  TX Indicates status of transmit path including normal operation and alarms such as forward / reverse power and temperature.  ON Blue LED indicates that there is power to the terminal. 9 RSSI RSSI test point suitable for 2 mm diameter multimeter test lead pin.
32  |  About the Terminal   Aprisa XE User Manual  Interface Card Types Each  terminal has  eight interface slots labeled  A  to H. Each slot  can be fitted with  any  interface card type. Typically, the terminal is delivered pre-configured with the requested interface cards. The following interface card types are currently available:  Name Interface card type Function QJET Quad E1/T1 interface card Four E1 / T1 interfaces (Framed or Unframed). Q4EM  Quad 4 wire E&M interface card Four 4 wire E&M voice channels DFXS Dual 2 wire FXS interface card Two 2 wire loop signalling foreign exchange subscriber (POTS) channels DFXO Dual 2 wire FXO interface card Two 2 wire loop signalling foreign exchange office channels HSS High-Speed Synchronous interface card A single high speed serial data channel configured as synchronous V.24, V.35, X.21, V.36 / RS-449, or RS-530. QV24 Quad V.24 serial interface card Four V.24 / RS-232 serial data channels Synchronous and asynchronous
 Mounting and Installing the Terminal  |  33  Aprisa XE User Manual  5. Mounting and Installing the Terminal This  section  covers  installing  the  hardware  associated  with  the  terminal.  Before  you  begin  a  terminal installation, read this section thoroughly.   CAUTION: You must comply with the safety precautions in this manual or on the product itself. 4RF  Limited  does  not  assume  any  liability  for  failure  to  comply  with  these precautions.   Required Tools No  special  tools  are  needed  to  install  the  terminal other  than  those  required  to  physically  mount  the terminal into the rack. Installing the Terminal The terminal is designed for 19-inch rack mounting and is supplied with rack mounting brackets. The rack brackets can be front, mid, or rear mounted (as shown below) to suit individual installation requirements. Once the rack brackets are attached, carefully lift the terminal into position in the rack, and fasten with screws and washers.
34  |  Mounting and Installing the Terminal   Aprisa XE User Manual  Installing the Antenna and Feeder Cable Carefully mount the antenna following the antenna manufacturers' instructions. Run feeder cable from the antenna to the terminal mounting location. Lightning protection must be incorporated into the antenna system. For more information, please contact Customer Support.   WARNING: When  the  link  is  operating,  there  is  RF  energy  radiated  from  the  antenna. Do not stand in front of or touch the antenna while the terminal is operating.  1. Fit  the  appropriate  male  or  female  N-type  connector  to  the  antenna  feeder  at  the  antenna  end. Carefully follow the connector manufacturers' instructions. 2. Securely attach the feeder cable to the mast and cable trays using cable ties or cable hangers. Follow the  cable  manufacturer's  recommendations  about  the  use  of  feeder  clips,  and  their  recommended spacing. 3. Connect  the  antenna  and  feeder  cable.  Ensure  the  N-type  connector  is  tight.  Weatherproof  the connection with a boot, tape, or other approved method. 4. Fit the appropriate N-type male connector to the antenna feeder at the terminal end (the terminal is N-type female). Carefully follow the connector manufacturer's instructions. 5. Connect the feeder cable to the antenna port on the terminal. Use a jumper cable, if needed. Ensure the N-type connector is tight. 6. Connect  a  coaxial  surge  suppressor  or  similar  lightning  protector  between  the  feeder  and  jumper cables (or at the point where the cable enters the equipment shelter). Earth the case of the lightning protector to the site Lightning Protection Earth. Also earth the terminal M5 earth stud to a protection earth.
 Mounting and Installing the Terminal  |  35  Aprisa XE User Manual  External Alarms Two external alarm inputs and four external alarm outputs are provided on the RJ-45 ALARM connector on the front panel. These enable an internal alarm to provide an external alarm to the network operator's existing  network  management  system  via  contact  closure  or  opening,  or  for  an  external  alarm  to  be transported via the radio link. The latency for an alarm presented on an external alarm input to the alarm being output on an external alarm output is < 2 seconds. Alarm  outputs  are  isolated  semiconductor  relay  type  contacts  rated  0  to  60  VDC  or  AC  rms  with  a maximum current of 100 mA. Alarm inputs are  isolated current  detectors  with  an operating voltage  range of  9  to  60 VDC or  AC  rms (effective current threshold of 5.0 to 6.5 mA constant current). The  common  reference  potential  for  the  two  external  alarm  inputs  must  be  applied  to  pin  3  and  the common reference potential for the four external alarm outputs must be applied to pin 4.  Alarm Circuit Setup A typical alarm circuit setup is:  An  external  battery  applied  to  the  ‘common  alarm  inputs  reference’  and  a  normally  open  relay contact  connected  to  the  alarm  input.  Closing  the  contact  applies  the  source  to  the  alarm  input detector  which  turns  the  alarm  on  (setup  for  ‘alarm  on  when  source  on’).  See  ‘Configuring  the External Alarm Inputs’ on page 81 for the setup options.   An  external  earth  applied to the ‘common alarm outputs reference’ and a ground  contact detector connected to the alarm output. When the alarm is on (active), the external alarm output relay contact closes (setup for ‘relay closed when alarm on’). See ‘Configuring the External Alarm Outputs’ on page 83 for the setup options.    The terminal front panel RJ-45 ALARM connections are:  RJ-45 pin Connection description TIA-568A wire colour 1 External alarm input 1 green / white 2 External alarm input 2 green 3 Common reference for alarm inputs 1 to 2 orange / white 4 Common reference for alarm outputs 1 to 4 blue 5 External alarm output 1 blue / white 6 External alarm output 2 orange 7 External alarm output 3 brown / white 8 External alarm output 4 brown
36  |  Mounting and Installing the Terminal   Aprisa XE User Manual  Interface Cabling  All interface cabling connections are made with RJ-45 male connectors which plug into the front of the interface cards (see ‘Interface Connections’ on page 257).  QJET Q4EM DFXO and DFXS The cabling to the QJET, Q4EM, DFXO and DFXS interface cards must have a minimum conductor size of 0.4 mm2 (26 AWG).  Ethernet Standard Ethernet network cables are used for all Ethernet port cabling.
 Mounting and Installing the Terminal  |  37  Aprisa XE User Manual  Power Supplies  US and Canada:  Installations should be in accordance with US National Electrical Code ANSI /  NFPA 70, and Canadian Electrical Code, Part 1 C22.1.   WARNING: Do not apply power to the terminal until you have completed installing the interface cards and connecting the antenna. Before  disconnecting  the safety  earth  during maintenance, remove AC or  DC  power supply connections, antenna cable and all interface cables from the terminal.  DC Power Supply There are four DC power supply options for the terminal; 12 VDC, 12 VDC Low Power, 24 VDC and 48 VDC. The DC inputs are polarity critical so the DC voltage must be applied with the correct polarity.  Nominal voltage Input voltage range Maximum Power input Maximum input current Recommended DC breaker rating +12 VDC LP 10.5 to 18 VDC 53 W 5 A 8 A ±12 VDC 10.5 to 18 VDC 180 W 18 A 25 A ±24 VDC 20.5 to 30 VDC 180 W 8 A 10 A ±48 VDC 40 to 60 VDC 180 W 4 A 5 A  CAUTION: An all-pole switch or DC circuit breaker of the rating shown in the table above must be fitted between the terminal DC input and the DC power source. Each terminal or MHSB terminal should have its own separate fuse or DC circuit breaker.  12 VDC / 24 VDC / 48 VDC Power Supply The power supply DC input is isolated from ground, so the DC power input can be either positive grounded or negative grounded. The positive or negative terminal should be connected to ground.  12 VDC LP Power Supply The 12 VDC Low Power is a high efficiency power supply for low power consumption applications up to a maximum of 53 watts input power (see ‘Power Consumption’ on page 312).  The DC input on this power supply is not isolated from ground as the negative input is internally connected to  ground via the Aprisa XE  chassis. The DC power  input for this power supply  must be a positive  12 V supply with the negative grounded.
38  |  Mounting and Installing the Terminal   Aprisa XE User Manual  DC Power Input Cabling The  DC  power  input  is  terminated  on  the  front  panel  of  the  terminal  with  two  high-current  M3  screw clamps for the positive and negative DC input and a M5 stud for the earth connection. The DC power cables have pre-terminated lugs to fit into the power input M3 screw clamps on one end and bare wire at the other end. The appropriate power cable for the power supply ordered is included in the accessory kit.   12 VDC LP / 24 VDC / 48 VDC Cable The  12  VDC  LP,  24  VDC  and  48  VDC  power  supplies  are  supplied  with  a  3  metre  red  /  black  cable  of 2.0 mm2 (23 strands of 0.32 mm2).      Terminal Power input Cable colour +V Positive DC input Red -V Negative DC input Black
 Mounting and Installing the Terminal  |  39  Aprisa XE User Manual  12 VDC Cable The 12 VDC power supply is supplied with a 3 metre red/black cable of two pairs of 2.3 mm2 (72 strands of 0.2 mm2) making a total of 4.6 mm2 per connection. This increase in wire size is to carry the increased current consumption of the 12 VDC supply (max 18 Amps per terminal).  This 3 metre cable is engineered to power a fully loaded terminal from a 12 VDC supply. A longer cable should not be used as the additional voltage drop could cause the power supply to fail. If longer cable runs are required between the 12 VDC power supply and the terminal, it is suggested that high current distribution bus bars are used to feed the rack and the supplied power cable used between the bus bars and the terminals.      Terminal Power input Cable colour +V Positive DC input Red -V Negative DC input Black     1.  Fit both pairs of lugs into the terminal screw clamps. 2.  Twist the other ends together when fitting to the source.
40  |  Mounting and Installing the Terminal   Aprisa XE User Manual  AC Power Supply There is one AC power supply for the  terminal. This AC power supply is  auto-sensing to operate with a nominal input voltage of 115 Vrms or 230 Vrms. The power input is terminated on the front panel of the terminal using a standard IEC plug. This power supply has a power on/off switch. A  power  cable  is  included  in  the  accessory  kit  and is  pre-fitted  with  an  IEC  socket  connector  and  the country-specific plug that was specified when the order was placed.  Nominal voltage Input voltage range Maximum Power input Max VA Frequency 115 VAC 103 - 127 Vrms 180 W 400 VA 47 - 63 Hz 230 VAC 207 - 254 Vrms 180 W 400 VA 47 - 63 Hz       Terminal Power input Cable colour E Earth Green/yellow N Neutral Blue L Line / Phase Brown      Important:  Please  check  with  your  local  power  authority  about  correct  colour  usage  and  pinouts. AC power cords used must be in accordance with national requirements.  Norway and Sweden: PLUGGABLE CLASS I EQUIPMENT intended for connection to a telephone network or similar  communications  system  requires  a  label  stating  that  the  equipment  must  be  connected  to  an earthed mains socket outlet.
 Mounting and Installing the Terminal  |  41  Aprisa XE User Manual  Brownout Recovery Module A Brownout Recovery Module (BRM) is factory fitted to the Aprisa XE motherboard power connector when the radio is fitted with an AC power supply. The AC power supply has a safety mechanism that trips the power if it detects a power input brownout. The BRM restarts the power supply after 3 seconds.
42  |  Mounting and Installing the Terminal   Aprisa XE User Manual  Safety Earth The terminal chassis must have a  protection / safety earth connected between the terminal  earth stud and  a  common  protection  earth  in  the  rack.  The  DC  power  input  can  be  either  positive  grounded  or negative grounded depending on the power supply system available.    Ground the terminal chassis using the terminal earth stud on the front panel as shown:
 Mounting and Installing the Terminal  |  43  Aprisa XE User Manual  Bench Setup Before installing the link in the field, it is recommended that you bench-test the link. A suggested setup for basic bench testing is shown below:        When setting up the equipment for bench testing, note the following:  Earthing—the terminal should be earthed at all times. The terminal earth stud must be connected to a protection earth.   Attenuators— In a bench setup, there must be 60 - 80 dB at up to 3 GHz of 50 ohm coaxial attenuation (capable  of  handling  the  transmit  power  of  +35dBm)  between  the  terminals’  N  type  antenna connectors. This can be achieved with two fixed attenuators fitted to the antennas 'N' connectors and a variable attenuator  with  a  ≥  60 dB  range. You can  use  other attenuator values  as  long  as  you  consider  the transmit power output level (max +33 dBm) and the receiver signal input (max -20 dBm).    Cables—use double-screened coaxial cable that is suitable for use up to 3 GHz at ≈ 1 metre.  CAUTION: Do not apply signals greater than -20 dBm to the antenna connection as they can damage the receiver.
 Connecting to the Terminal  |  45  Aprisa XE User Manual  6. Connecting to the Terminal Connecting to the Terminal's Setup Port You can configure basic terminal settings by connecting to the terminal using the Setup cable. This can be useful if you need to confirm the terminal's IP address, for example. You can password-protect the setup menu to prevent unauthorized users from modifying terminal settings.  A straight RJ-45 connection cable and a RJ-45 to DB-9 adapter is provided with each terminal.  1. Plug the DB-9 into serial port of the PC. 2. Plug the RJ-45 connection cable into the adaptor as shown below:    3. Plug the other end of the RJ-45 connection cable into the SETUP port of the terminal.  Note: Connecting the PC serial port to the Interface Cards or ALARM connectors may result in damage to the PC or terminal. Ensure that the RJ-45 connection cable is connected to the RJ-45 connector marked 'SETUP'.    Cable pinouts (RJ-45 to DB-9) If you need a conversion connector or cable, refer to the following table: Console port (DCE, RJ-45) RJ-45 to RJ-45 cable RJ-45 to DB-9 adaptor PC port  (DTE, DB-9) Signal RJ-45 pin RJ-45 pin RJ-45 pin DB-9 pin Signal RTS 1 1 1 7 RTS DTR 2 2 2 4 DTR TXD 3 3 3 3 TXD GND 4 4 4 5 GND GND 5 5 5 NC NC RXD 6 6 6 2 RXD DSR 7 7 7 6 DSR CTS 8 8 8 8 CTS
46  |  Connecting to the Terminal   Aprisa XE User Manual  Configure the PC COM Port Settings Terminal emulation software e.g. HyperTerminal is used to setup the basic configuration of a terminal. The PC's COM port settings must be setup as follows:  Bits per second 115200 Data bits 8 Parity None Stop bits 1 Flow Control None  Start a HyperTerminal Session 1. On the PC, select Start > Programs > Accessories > Communications > HyperTerminal. 2. Enter a name for the connection and click OK.  3. Select the designated COM Port from the Connect Using drop-down box. Ensure it is the same COM port that you configured earlier on your PC. Click OK.  Note: The Country/region, Area code, and Phone number information will appear automatically.
 Connecting to the Terminal  |  47  Aprisa XE User Manual  4. Set the COM Port settings as follows:    5. When you have completed the settings, click OK, which will open the HyperTerminal window. 6. Apply power to the terminal.   Note:  If  power  was  applied  to  the  terminal  before  launching  HyperTerminal,  hit  the  Enter  key  to initiate the link.  When the terminal has completed startup, you will be presented with the Setup menu:
48  |  Connecting to the Terminal   Aprisa XE User Manual  Connecting to the Terminal's Ethernet Interface  The  main  access  to  a  terminal  for  management  is  with  the  ethernet  interface  using  standard  IP networking. There should be only one ethernet connection from the terminal to the management network.  The  terminals  are  pre-configured  to  use  IP  addressing  in  one  of  the  common  'non-routable'  IP  address ranges.  This  means  the  terminals  are  usually  recognized  by  your  operating  system  without  any reconfiguration. However,  you should change these default addresses  (see  ‘Changing  the Terminal’s IP  Address’ on page 64) to comply with your IP addressing scheme.  In the example below, the active management PC must only have one connection to the link as shown by path . There should not be any alternate path that the active management PC can use via an alternate router or alternate LAN that would allow the management traffic to be looped as shown by path .
 Connecting to the Terminal  |  49  Aprisa XE User Manual  PC Requirements for SuperVisor SuperVisor requires the following minimum PC requirements:  Microsoft Windows 2000, NT, XP, Vista or Windows 7  Personal computer with 1.6 GHz Pentium IV  512 MB of RAM  200 MB of free hard disk space  Ethernet interface (Local Area Network)  COM port  Web  browser  with  a  Java  plug-in  such  as  Mozilla  FireFox  (recommended),  Microsoft  Internet Explorer 5.0, or Netscape Navigator 6.0, but SuperVisor also supports other major web browsers.  Java JRE 1.6.   Note: Mozilla Firefox, Internet Explorer and the Java JRE are provided on the Aprisa CD (see ‘Aprisa XE CD Contents’ on page 20).
50  |  Connecting to the Terminal   Aprisa XE User Manual  PC Settings for SuperVisor  To change the PC IP address: If your PC has previously been used for other applications, you may need to change the IP address and the subnet mask settings. You will require Administrator rights on your PC to change these. Windows XP example: Configure IP settings 1. Open the 'Control Panel'. 2. Open 'Network Connections' and right click on the 'Local Area Connection' and select 'Properties'.  3. Click on the 'General' tab.  4. Click on 'Internet Protocol (TCP/IP)' and click on properties. 5. Enter the IP address and the subnet mask (example as shown). 6. Click 'OK' then close the Control Panel. If the terminal is on a different subnet from the network the PC is on, set the PC default gateway address to  the  network  gateway  address  which  is  the  address  of  the  router  used  to  connect  the  subnets  (for details, consult your network administrator).
 Connecting to the Terminal  |  51  Aprisa XE User Manual  To change the PC connection type: If your PC has previously been used with Dial-up connections, you may need to change your PC Internet Connection setting to 'Never dial a connection'. Windows XP example: Configure Windows to Never Dial a Connection 1. Open the 'Control Panel'. 2. Open 'Internet Options' and click on the 'Connections' tab.  3. Click the 'Never dial a connection' option.  4. Click 'OK' then close the Control Panel.
52  |  Connecting to the Terminal   Aprisa XE User Manual  To change the PC pop-up status: Some functions within SuperVisor require Pop-ups enabled e.g. saving a MIB Windows XP example: Configure explorer to enable Pop-ups 1. Open the 'Control Panel'. 2. Open 'Internet Options' and click on the 'Privacy' tab.   3. Click on 'Settings'.  4. Set the 'Address of Web site to allow' to the terminal address or set the 'Filter Level' to  'Low: Allow Pop-ups from secure sites' and close the window. 5. Click 'OK' then close the Control Panel.
 Connecting to the Terminal  |  53  Aprisa XE User Manual  IP Addressing of Terminals When logging into a link, it is important to understand the relationship between the Local / Remote and the Near end / Far end terminals. The Near end terminal is the terminal that has its ethernet port physically connected to your IP network. The Far end terminal is the terminal that is at the other end of the link from the Near end terminal and communicates through the management connection over the radio link to the Near end terminal. The Local terminal is the terminal that SuperVisor is logged into and is displayed on the left hand side of the SuperVisor screen. The Local terminal can be the Near end or Far end terminal. The Remote terminal is the terminal that is at the other end of the link from the Local terminal and is displayed on the right hand side of the SuperVisor screen. To prevent confusion when operating SuperVisor, determine the IP address of the Near end terminal and log into that terminal. This is now the Local terminal. The distinction is important as:  Some functions can only be carried out on the Local terminal.  Having  different  configurations  at  each  end  of  the  link  will  disrupt  communications  between  the terminals. In these circumstances it is important to make changes to the Far end terminal of the link first.  The  link  is  then  lost  only  until  the  near  end  configuration  is  completed  and  communication restored.  If the Near end terminal is modified first, the link is lost for much longer as staff will have to either physically visit the Far end terminal to restore the link, or restore the near end to match the far end, re-establish the link, then start the process again, this time with the Far end terminal first.
54  |  Connecting to the Terminal   Aprisa XE User Manual  Network IP Addressing  Same Subnet as the Local PC The following diagram shows a link interconnected on the same subnet as the local PC terminal used for configuration.  In  this example, the  local  PC, as  well  as  the  local and remote terminals, are  on  the  same  subnet  and therefore have the same subnet mask 255.255.255.0. This will allow the PC and the terminals to communicate with each other.
 Connecting to the Terminal  |  55  Aprisa XE User Manual  Different Subnet as the Local PC The  following  diagram  shows  a  link  interconnected  on  a  different  subnet  as  the  local  PC  used  for configuration, and communicating through a network. This can be achieved on the condition that network router(s) 1 and 2 are programmed to recognize each other and the various subnets on the overall network.
 Managing the Terminal  |  57  Aprisa XE User Manual  7. Managing the Terminal The command line setup menu can be used to:  Provide basic access to the terminal to set IP addresses  Check or set basic settings of the terminal  4RF SuperVisor is an embedded element manager for the Aprisa XE terminal which is used to:  Configure radio and interface parameters  Setup cross connections between traffic interfaces  Monitor performance, terminal status and alarm details  The Setup Menu  1. Initiate the link by either applying power to the terminals or, if the terminals are already powered up, pressing the Enter key.  2. At the prompt, enter your selection:   Selection Explanation 1) Dump terminal configuration This shows basic terminal data such as Terminal ID, IP data and radio parameters of TX and RX frequency, TX power, modulation type and channel size. 2) Not used  3) Configure IP addresses Use this if you want to set the IP address, subnet mask or gateway address of the local terminal. 4) Configure SNMP Use to display SNMP settings, setup the SNMP Access Controls and Trap Destinations and reset SNMP settings to defaults. 5) Set hostname Use this to set a name that can be used in conjunction with DNS. 6) Configure remote terminal address Use this to set the IP address of the remote terminal. 7) Reset web server users Deletes all existing usernames and passwords in the ‘User Table’ and restores default usernames and passwords. 8) Not used  9) Reboot Reboots the terminal. 10) Configure Ethernet Use this to display the Ethernet configuration and reset the Ethernet settings to the defaults. 11) Password Protect Menu Use this to password-protect the menu to prevent unauthorized users from modifying terminal settings. The password is setupxe.
58  |  Managing the Terminal   Aprisa XE User Manual  To Get or Set the IP Address of a Terminal Using Setup  To get the IP address of a terminal using setup: 1. At the prompt, type 1 and enter.  The following information appears:  the IP addresses of the local and remote terminals  the subnet mask and gateway of the local terminal  the TFTP of the remote terminal  To set the IP address of a terminal using setup: 1. At the prompt, enter 1. 2. Enter 3 to configure the local terminal IP address. Set the following for the terminal using the standard format xxx.xxx.xxx.xxx:  1) IP address  2) Subnet mask  3) Gateway address 3. Enter 4 (Quit) to return to the main menu. 4. Enter 6 to configure the remote terminal IP address. Important: You must ensure that the IP addresses of the local and remote terminals are on the same subnet as the PC being used to configure the terminals.   5. Enter 4 (Quit) to return to the main menu.  6. Enter 9 (Are you sure y/n) to reboot the terminal.
 Managing the Terminal  |  59  Aprisa XE User Manual  SuperVisor The SuperVisor management software is pre-loaded into an integrated web-server within the terminal. SuperVisor runs on any Java-enabled web browser.   You can use SuperVisor to:  display and configure terminal parameters  view the terminal alarms  monitor the performance and status of the link  upgrade the terminal software  save and load configuration files  save performance and error information to a log file
60  |  Managing the Terminal   Aprisa XE User Manual  SuperVisor Logging In The maximum number of concurrent users that can be logged into a terminal is 5. If SuperVisor is inactive for a period of 30 minutes, the terminal will automatically log out the user. To log in to SuperVisor: 1. Open your web browser and enter the IP address of the terminal.  Note: If you haven't yet assigned IP addresses to the terminals, use the factory-configured IP addresses (see ‘Changing the Terminal’s IP Address’ on page 64). If  you  don't  know  the  IP  address  of  the  terminal,  you  can  determine  it  using  terminal  emulation software (see ‘To Get or Set the IP Address of a Terminal Using Setup’ on page 58).    2. Login with the user name and password assigned to you. Note: If unique user names and passwords have not yet been configured, use the default user names and passwords (see ‘Setting up users’ on page 65).      Important:  After  you  login  for  the  very  first time,  it  is  recommended  that  you  change  the  default admin password for security reasons (see ‘Changing passwords’ on page 67).  3. Tick the ‘Use Popup Window’ tick box if you want a separate browser window to launch after you have logged in. The login page remains open in one window allowing you to view or configure settings in another  page.  This  is  useful  if  you  have  more  than  one  link  to  configure,  for  example,  protected terminals. 4. When  you  have  logged  in,  the  Summary  page  shows  a  summary  of  both  the  Local  and  Remote terminals’ parameters.
 Managing the Terminal  |  61  Aprisa XE User Manual  SuperVisor Logging Out As  the  maximum  number  of  concurrent  users  that  can  be  logged  into  a  terminal  is  5,  not  logging  out correctly can restrict access to the terminal until the after the timeout period (30 minutes). Logging out from a terminal will logout all users logged in with the same user name. If the SuperVisor window is closed without logging out, the terminal will automatically log the user out after a timeout period of 30 minutes. To log out of SuperVisor: 1. Click on the ‘Logout’ button on the Summary Bar.
62  |  Managing the Terminal   Aprisa XE User Manual  SuperVisor Main Screen  The SuperVisor Main Screen presents a summary of both the local and remote terminals and the status of the terminal front panel LED indicators:
 Managing the Terminal  |  63  Aprisa XE User Manual  SuperVisor Menu Bar The SuperVisor Menu Bar at the top of the screen shows the names of the terminals, the top level menus and three status indicators  for both the local and remote terminals.  These  indicators reflect the status LED indicators on the front panel of terminal.    There are four menus available:  Link - menu options for both terminals in a link  Local - menu options for the local terminal in a link  Remote - menu options for the remote terminal in a link  Help - provides details about the terminal  SuperVisor Summary Bar    The SuperVisor Summary Bar at the bottom of the screen shows:  The login name of the person currently logged in together with the name of the local terminal and its IP address.  A login alarm that indicating that someone else has logged into and could be working on the same link. The LED is green for 1 user and yellow for more than 1 user.  The number of users logged in to the link  A SuperVisor logout button
64  |  Managing the Terminal   Aprisa XE User Manual  Changing the Terminal’s IP Address You can use SuperVisor to change the IP address of the terminal from the default.  Alternatively, you can assign the IP address using the SETUP port (see ‘To Get or Set the IP Address of a Terminal Using Setup’ on page 58).  To change the IP address of the terminals using SuperVisor: 1. Launch your web browser and connect to the terminal using the one of the factory-configured default IP addresses shown below:   Terminal IP address Unprotected terminals Terminal 1 (local) 169.254.50.10  Terminal 2 (remote) 169.254.50.20    Protected terminals Terminal 1, terminal A (local) 169.254.50.10  Terminal 1, terminal B (local) 169.254.50.11  Terminal 2, terminal A (remote) 169.254.50.20  Terminal 2, terminal B (remote) 169.254.50.21  Note: The factory default settings for the subnets is 255.255.0.0; the gateway is 0.0.0.0.  2. Log into the terminal as the administrator with the user name 'admin' and the password 'admin'.  Note: For security reasons, change the admin password (see ‘Changing passwords’ on page 67) as soon as possible.  3. Select Link or Local or Remote > Terminal > Advanced and make the necessary changes.  Note: If this IP address change is being made over the RF link, it is important to change the far end of the link first.  4. Once you have changed the IP address of a terminal, you must perform a hard reboot of the terminal and then reconnect to it using the new IP address.
 Managing the Terminal  |  65  Aprisa XE User Manual  Setting Up Users  Note: You must login with 'admin' privileges to add, disable, delete a user or change a password.  User groups There  are  three  pre-defined  user  groups  to  allocate  access  rights  to  users.  These  user  groups  have associated default user names and passwords of the same name.  User Group Default User Name Default Password Access Rights View view view Users in this group can only view terminal parameters. Modify modify modify Users in this group can view and edit terminal parameters. Admin admin admin Users in this group have full access to all terminal parameters including the ability to add and change users.  Adding a User 1. Select Local or Remote > Maintenance > User Admin > User Table. 2. Select an empty line (that isn't allocated to an existing user) and then click Edit.  3. Enter the user name. A  user  name can  be  up to  32  characters  but  cannot contain  back  slashes, forward slashes,  spaces, tabs, single or double quotes. 4. Enter the Password and the Confirm Password. A password can be up to 32 characters but cannot contain back slashes, forward slashes, spaces, tabs, single or double quotes. 5. Select the group that they will belong to (View, Modify, or Admin). 6. If the user requires immediate access, enable the user by clicking on Yes.  7. Click Apply. Note 1: The new user must be setup on both the Local and Remote terminals. Note 2: For the changes to take effect, you must reboot the terminal (Local > Maintenance > Reboot).
66  |  Managing the Terminal   Aprisa XE User Manual  Disabling a User 1. Select Local or Remote > Maintenance > User Admin > User Table. 2. Select the user who you want to disable. 3. Click Edit to display the User details and set Enabled to 'No'. 4. When  you  have  made  your  changes,  click  Apply to  apply  changes  or  Reset  to  restore  the  previous configuration. Note: For the changes to take effect, you must reboot the terminal (Local > Maintenance > Reboot).  Deleting a User 1. Select Local or Remote > Maintenance > User Admin > User Table. 2. Select the user you want to delete. 3. Click Edit to display the user details and delete the User Name and Password.  4. Reset the Group to 'View' and set Enabled to 'no'. 5. When  you  have  made  your  changes,  click  Apply to  apply  changes  or  Reset  to  restore  the  previous configuration. Note: For the changes to take effect, you must reboot the terminal (Local > Maintenance > Reboot).  Saving User Information You can save the list of users to your PC and then load this file to another terminal. This is useful if you have multiple terminals to configure.  To save the user table to file: 1. Select Local > Maintenance > User Admin > Save User List. 2. Select the 'Save to disk' option in the dialog box that appears.  3. In the next dialog box that appears, navigate to the directory where you want to save the file, enter a suitable filename, and then click Save (The default name for this file is 'downloadUsers'). Note: If this dialog box does not appear, change your Internet security settings to allow downloads. You may also need to check your file download location setting.  To save the file to another terminal: 1. Select Local > Maintenance > User Admin > Load User List. 2. On the Upload Users page, select Browse and navigate to the file on your PC. 3. Click Apply. The User Table appears and you can edit users, as required.
 Managing the Terminal  |  67  Aprisa XE User Manual  Changing Passwords 1. Select Local or Remote > Maintenance > User Admin > User Table.   2. Select the user whose password you want to change and click Edit. 3. Enter the new Password and the new Confirm Password. A password can be up to 32 characters but cannot contain back slashes, forward slashes, spaces, tabs, single or double quotes. 4. When you have made your changes, click Apply.  Viewing User Session Details Administrators can check who is currently logged in, the computer they are logging in from, and how long they have been logged in for. Note: A  'session'  is the period  of time that begins when someone  logs into the terminal and ends when they logout.  To view user session details: 1. Select Local > Maintenance > User Admin > Session Details.    The 'Session Details' shows a list of the current users:  User Name: the User Name logged into the terminal.  Time: the number of minutes the user has been logged in.  Last Access: the number of minutes the user last accessed the terminal in this session.   Address: the address of the computer or proxy server address logged into the terminal.
 Configuring the Terminal  |  69  Aprisa XE User Manual  8. Configuring the Terminal Configuring the RF Settings The RF settings are factory-configured before dispatch to the customer requirements. However, you can change the RF settings, if required.  If  two fundamental radio parameters  (RX and  TX frequency  or modulation)  are changed on  the remote terminal  in  the  same  apply  action  (simultaneously),  the  first  parameter  change  could  break  the communications link to the remote terminal and prevent the other commands from being actioned. There is a two second delay between receiving the command and actioning it to allow for subsequent commands to be received before the communications link is lost.  To configure RF settings: Select Link or Local or Remote > Terminal > Basic:    Note:  Transmit  frequency,  transmit  power,  channel  size,  modulation  and  antenna  polarization  would normally be defined by a local regulatory body and licensed to a particular user. Refer to your site license details when setting these fields.
70  |  Configuring the Terminal   Aprisa XE User Manual  RX and TX Frequency The local terminal transmit frequency must match the receive frequency of the remote terminal and the remote terminal transmit frequency must match the receive frequency of the local terminal. When setting the RX and TX frequency with SuperVisor, the frequency entered is automatically resolved to the synthesizer step size for the terminal frequency band e.g. an ETSI 1400 MHz band frequency entry of 1474,010,000 Hz will  be changed to 1474,012,500 Hz (see synthesizer step size  in the table  ‘Frequency Bands’ on page 287).  The RX and TX frequency entered must be:  Within  the  frequency  band  limits  of  the  chosen  RF  frequency  band  of  the  terminal  as  specified  in ‘Frequency  Bands’  on  page  287. e.g. for an ETSI frequency  band of  1400 MHz, the frequency band limits are 1350 to 1550 MHz.  Within  the  TX  /  RX  passband  of  the  duplexer  fitted  in  the  terminal  e.g.  for  a  frequency  band  of 1400 MHz, the standard duplexer passband is 7 MHz and the TX / RX split is   48 MHz (see Duplexer (bandpass) ‘Duplexers’ on page 301). The duplexer passband and center frequencies are written on the duplexer label.  The TX and RX frequencies are validated against the duplexer parameters entered on SuperVisor  Link or Local or Remote > Terminal > Duplexer (see ‘Setting the Duplexer Parameters’ on page 79). If the TX or RX frequency entered is not valid i.e. outside the operating range of the duplexer, a warning message will popup. OK accepts the frequency entered and cancel rejects the frequency entered.  Important: Changing the remote terminal RX or TX frequency will disable all management communication to the remote terminal but by changing the local terminal to match the remote terminal, the radio link will be restored as will the management communication BUT  if  the  remote  terminal  RX  or  TX  frequency  is  changed  to  be  outside  the  operating  range  of  the terminal, changing the local terminal to match the remote terminal will not restore the radio link and all management communication will be lost.  The remote terminal TX and RX frequencies cannot be changed simultaneously i.e. change one direction and ‘Apply’ the change and then change the other direction and ‘Apply’ the change. To change both TX and RX frequencies: 1. Change the remote terminal RX frequency and ‘Apply’ the change. The radio link will fail. 2. Change the local terminal TX frequency to that of the remote RX frequency and ‘Apply’ the change. The radio link will restore. 3. Change the remote terminal TX frequency and ‘Apply’ the change. The radio link will fail. 4. Change the local terminal RX frequency to that of the remote TX frequency and ‘Apply’ the change. The radio link will restore.  Transmit power The transmitter power is the power measured at the duplexer output port. The transmitter power adjustment range varies depending on the Modulation type and frequency band of the terminal. For ETSI transmitter power range see ‘Transmitter Power ETSI’ on page 290.
 Configuring the Terminal  |  71  Aprisa XE User Manual  Channel size The RF channel size is a factory-configured setting determined by the Aprisa XE hardware option.  Modulation Both terminals must be set to the same modulation type. When  you  change  the  modulation  type  in  an  operational  terminal,  traffic  across  the  link  will  be interrupted and you may need to change the cross connections capacity, as the Total Capacity of the radio link may be exceeded.  Interleaver state This Interleaver State displays the current state of the modem interleaver.  Interleaver State Modem Interleaver Operation Default The modem interleaver is on for channel sizes of 250 kHz and greater and off for channel sizes of 200 kHz and less. Enabled The modem interleaver is on. Disabled The modem interleaver is off.
72  |  Configuring the Terminal   Aprisa XE User Manual  Modem Performance Settings To view or change the modem performance settings: Select Link or Local or Remote > Terminal > Modem    Modem QPSK Coding When the Modulation  type is set to QPSK, the default QPSK Coding  setting is ‘Non-Gray Coded’ but the QPSK Coding can use ‘Gray Coded’ for interoperability with older hardware.  Modem Interleaver Mode The  Modem  Interleaver  improves  modem  bit  error rate  but  increases the end  to  end link  delay  so  the Modem Interleaver should be enabled where a low bit error rate is required and disabled where a low end to end link delay is required. The ‘Default’ Modem Interleaver Mode setting is on for channel sizes of 250 kHz and greater and off for channel sizes of 200 kHz and less. The specification of end to end link delay for both interleaver on and off is given in the relevant RF Specification section. For ETSI Link Delays, see ‘Link Delays ETSI’ on page 292. When you change the Modem Interleaver Mode in an operational terminal, traffic across the link will be interrupted. Both terminals must be set to the same Modem Interleaver Mode.
 Configuring the Terminal  |  73  Aprisa XE User Manual  Modem Mute Mode The Aprisa XE radio always mutes its interface ports when the modem loses lock. The  Modem  Mute  feature  mutes  its  interface  ports  when  the  modem  Reed  Solomon  forward  error correction capability can no longer correct errors.    This can occur when the signal strength of the RF link reduces to within about 2  dB of the theoretical sensitivity  of the  radio  or  when the radio is  operating  well  above  the  sensitivity threshold  but  is in  an environment subject to impulse noise interference on the RF path. When the mute activates;  On  the  analog  cards,  Q4EM, DFXS and  DFXO, the audio  path  mutes and the signalling states go idle.  On the digital cards, QV24  and HSS, it causes  an all ones data pattern to be  driven on the  RXD output line and handshake lines such as RTS / CTS to their off states while on the QJET card it forces the ports to an AIS state.  The Modem Mute feature effectively reduces the radio receiver sensitivity by 2 to 3 dB from its published values but will prevent errors from corrupting the tributary audio circuits.  Modem Mute Time The  Modem Mute  Time determines the time the mute  will persist  after  the  last  uncorrectable block  is received. This can be set from 0 to 10 seconds in 0.1 second steps.  Note: The Modem Mute feature is only available if the radio modem is Rev D or later. If the radio has a Rev A, Rev B or Rev C modem, the modem mute functionality is not displayed in SuperVisor.
74  |  Configuring the Terminal   Aprisa XE User Manual  Entering Basic Terminal Information  To enter basic terminal information: Select Link or Local or Remote > Terminal > Basic    Terminal Information The data entry in these four fields can be up to 40 characters but cannot contain back slashes or double quotes.  1. Enter the terminal Name. This appears in the Terminal status and menu bar at the top of every page.  2. Enter a unique Terminal ID.  3. Enter the Location of the terminal.  4. Enter a contact name or an email address in Contact Details. The default value is ‘support@4RF.com’.  5. Click Apply to apply changes or Reset to restore the previous configuration.
 Configuring the Terminal  |  75  Aprisa XE User Manual  Configuring the IP Settings  Select Link or Local or Remote > Terminal > Advanced.    Advanced Terminal Settings 1. Enter  the  static  IP  Address  for  the  terminal  assigned  by  your  site  network  administrator  using  the standard format xxx.xxx.xxx.xxx. The default IP address is in the range 169.254.50.xx. 2. Enter the Subnet Mask for the terminal using the standard format xxx.xxx.xxx.xxx. The default subnet mask is 255.255.0.0. 3. Enter the Default Gateway for the terminal, if required, using the standard  format xxx.xxx.xxx.xxx (there is no default gateway set by default.) 4. Enter the IP address of the remote terminal using the standard format xxx.xxx.xxx.xxx (the default IP address is in the range 169.254.50.xx.)  5. If you are setting up for remote logging (see ‘Setting up for Remote Logging’ on page 255), enter the Syslog Address and the Syslog Port for the remote terminal.  6. In Time Zone Offset from GMT, select the time zone from the list (optional) .  7. To set the Time to the PC real-time clock, click Now.  8. Click Apply to apply changes or Reset to restore the previous configuration.
76  |  Configuring the Terminal   Aprisa XE User Manual  Setting the Terminal Clocking  To view the terminal clock status: Select Link or Local or Remote > Terminal > Clocking The current selected clock source and the current status of the primary and secondary external clocks are shown:  Clock Status Clock Status Description Inactive This clock source is either not configured at all, or is not in current use Active This clock source is providing the clocking for the terminal Holdover This clock source is nominated as Primary or Secondary but is currently unavailable.
 Configuring the Terminal  |  77  Aprisa XE User Manual  To select the terminal clock source: The Clock Source selected for the terminal will be used to clock all interface ports requiring clocking and send a clocking signal over the RF link. Select Link or Local or Remote > Terminal > Clocking > Clock Source and select one of the following:  Clock Source Terminal Clocking External The terminal is clocked from the nominated interface port selected as the primary external clock or the secondary external clock. Internal The terminal is clocked from the terminal's internal clock. Link The terminal is clocked from the RF link.    If the terminal Clock Source is set to External, the terminal will automatically clock from the nominated primary external clock source if that clock source is available. If  the  nominated  primary  external  clock  source  is  not  available,  the  terminal  will  clock  from  the nominated secondary external clock source if that clock source is available. If the nominated secondary external clock source is not available, the terminal will clock from the internal clock source. When a nominated external clock source becomes available (primary or secondary), the terminal will then clock from that clock source.  The terminal at one end of the link must have its clock source set to Internal or External and the terminal at the other end of the link must have its clock source set to Link.
78  |  Configuring the Terminal   Aprisa XE User Manual     To select the interface port for the external clock source (external clock source only): Select  the  traffic  interface  ports  nominated  as  Primary  External  Clock  or  Secondary  External  Clock sources. The failure of both External Clock sources results in a major alarm.  To manually override the automatic clock source selection (external clock source only): Select either Switch to Primary or Switch to Secondary from the drop-down list, and click Apply.
 Configuring the Terminal  |  79  Aprisa XE User Manual  Setting the Duplexer Parameters  To set the duplexer parameters: Select Link or Local or Remote > Terminal > Duplexer    Duplexer Parameters The terminal TX  and RX frequencies  entered  are  validated against the duplexer parameters entered on this page.  A valid high port frequency must be:  (duplexer high port centre frequency + pass band/2 - channel size/2) and  (duplexer high port centre frequency – pass band/2 + channel size/2)  A valid low port frequency must be:  (duplexer low port centre frequency + pass band/2 - channel size/2) and  (duplexer low port centre frequency – pass band/2 + channel size/2)  The duplexer parameters are entered in the factory but can be re-entered if the duplexer is changed in the field. The parameters required are shown on the duplexer label.  1. Enter the duplexer High port centre frequency and Low port centre frequency in MHz.  2. Enter  the  duplexer  Pass  band  in  MHz  (the  total  passband e.g.  if  the  duplexer passband  is  show  as ± 3.5 MHz, the value entered is 7 MHz).  3. Select Transmit High or Transmit Low  Transmit High - the Transmitter is connected to the High Port of the duplexer. Transmit Low - the Transmitter is connected to the Low Port of the duplexer.  4. Enter the duplexer Serial Number (used for record keeping only).  5. Click Apply to apply changes or Reset to restore the previous configuration.
80  |  Configuring the Terminal   Aprisa XE User Manual  Setting the RSSI Alarm Threshold The threshold (in dB) at which the RSSI alarm activates can be set for each of the modulation types over the adjustment range of -40 dBm to -110 dBm and the default values are as per the following screen shot. The alarm threshold has a +1 dB hysteresis for the inactive state.  To set the RSSI alarm threshold: Select Link or Local or Remote > Alarms > RSSI Thresholds    1. Enter the alarm threshold required for each of the modulation types.  2. Click Apply to apply changes or Reset to restore the previous configuration.
 Configuring the Terminal  |  81  Aprisa XE User Manual  Configuring the External Alarms Each terminal has two external alarm inputs and four external alarm outputs, terminated on the ALARM RJ-45 connector on the terminal front panel.  Each  external  alarm  input  can  activate  the  Major  /  Minor  terminal  alarm  or  be  mapped  to  a  remote terminal external alarm output. The ‘Alarm On When’ (active alarm state) for both inputs can be configured for 'External  Source On' or 'External Source Off' (default is External Source On).  Each external alarm output can be triggered by a local terminal Major / Minor alarm or a remote terminal Major / Minor alarm or either of the remote external alarm inputs. The ‘Relay Closed When’ for the four outputs can be configured for 'Alarm On' or 'Alarm Off' (default is Alarm Off).  Configuring the External Alarm Inputs  To configure the External Alarm Inputs: Select Link or Local or Remote > Alarms > Ext Alarm Inputs  Note: When the MHSB mode is enabled on the terminal, the external alarm input 2 is used for protection switch control so is not available for user alarms.   The  state  of  the  local  terminal  external  alarm  input  is  always  sent  to  the  remote  terminal  and  the external alarm input can be mapped to a remote terminal external alarm output. Alarms present on  a  local terminal  external alarm input  will  only  be  displayed in  the remote  terminal Alarm Table / Alarm History if it has been mapped to one of the remote terminal external alarm outputs.
82  |  Configuring the Terminal   Aprisa XE User Manual  1. Select the Display Locally setting for each alarm input.  Display Locally External Alarm Input Function  No The external alarm input does not generate an alarm on the local terminal, does not appear in the ‘Alarm Table’ or ‘Alarm History’, and shows as grayed out on the ‘Alarm Summary’. Default Yes The external alarm input generates an alarm on the local terminal, displays in the ‘Alarm Table’ and ‘Alarm History’ and the ‘Alarm Summary’.   2. Select the Severity setting for each alarm input.  This option is only relevant when the ‘Display Locally’ option is set to ‘Yes’.  Severity External Alarm Input Severity  Minor The external alarm input generates a minor alarm on the local terminal. Default Major The external alarm input generates a major alarm on the local terminal.   3. Enter a Description for each alarm input. The default is ‘External Input 1’ / ‘External Input 2’.  4. Select the Alarm On When setting for each alarm input.  Alarm On When External Alarm Input State  External Source On The alarm is on (alarm active) when a source of voltage is applied to the external alarm input and current is flowing. Default External Source Off The alarm is on (alarm active) when no source of voltage is applied to the external alarm input and hence no current is flowing.   5. When  you  have  made  your  changes,  click  Apply to  apply  changes  or  Reset  to  restore  the  previous configuration.
 Configuring the Terminal  |  83  Aprisa XE User Manual  Configuring the External Alarm Outputs To configure the External Alarm Outputs: Select Link or Local or Remote > Alarms > Ext Alarm Outputs  Note: When the MHSB mode is enabled on the terminal, the external alarm output 4 is used for protection switch control so is not available for user alarms.   1. Select the Mapping required for each alarm output.  Mapping External Alarm Output Function  None No external alarm output. Default Local Major The external alarm is present when the local terminal has a major alarm.  Local Minor The external alarm is present when the local terminal has a minor alarm.  Remote Major The external alarm is present when the remote terminal has a major alarm.  Remote Minor The external alarm is present when the remote terminal has a minor alarm.  Remote Input 1 The external alarm is present when the remote terminal external alarm input 1 is present.  Remote Input 2 The external alarm is present when the remote terminal external alarm input 2 is present.  Test Major External alarm test function – major alarm This setting will output an alarm on the selected output but it will not show in the alarm table or on the OK LED of the radio (it is not a 'real' alarm). This alarm test will clear if radio reboots.  Test Minor External alarm test function – minor alarm This setting will output an alarm on the selected output but it will not show in the alarm table or on the OK LED of the radio (it is not a 'real' alarm). This alarm test will clear if radio reboots.
84  |  Configuring the Terminal   Aprisa XE User Manual  2. Select the Relay closed when setting for the four alarm outputs.  Relay closed when External Alarm Output State  Alarm on When the external alarm output relay contact is closed, the alarm is on (alarm active). Default Alarm off When the external alarm output relay contact is closed, the alarm is off (alarm inactive).   3. When  you  have  made  your  changes,  click  Apply to  apply  changes  or  Reset  to  restore  the  previous configuration.
 Configuring the Terminal  |  85  Aprisa XE User Manual  Configuring SNMP Settings In addition to web-based management (SuperVisor), the terminal can also be managed using the Simple Network Management Protocol (SNMP). MIB files are supplied, and these can be used by a dedicated SNMP Manager, such as Castle Rock's SNMPc (www.castlerock.com), to access most of the terminal's configurable parameters.  However,  it  is  recommended  that  SNMP  is  only  used  for  status  and  alarm  monitoring  of  your  entire network. SuperVisor is the best means to configure individual terminals. For communication between the SNMP manager and the terminal, Access Controls, Trap Destinations, and Community strings must be set up as described in the following sections.  A SNMP Access  Control is the IP address of the terminal used by an SNMP manager or any other SNMP device to access the terminal. Entering an IP address of ‘Any’ (not case sensitive) or * will allow any IP address access to the terminal. A community string is sent with the IP address for security.  Commands  are  sent  from  the  SNMP  manager  to  the  terminal  to  read  or  configure  parameters  of  the terminal e.g. setting of interface parameters.  A SNMP Trap Destination is the IP address of a station running an SNMP manager. A community string is sent with the IP address for security. Events are sent from the terminal to the SNMP manager e.g. alarm events.  A  SNMP  Community  String  is  used  to  protect  against  unauthorized access (similar to  a  password).  The SNMP  agent  (terminal  or  SNMP  manager)  will  check  the  community  string  before  performing  the  task requested in the  SNMP message  . Trap  Destinations and Access Controls both use community strings for protection.  To configure Trap Destinations and Access Controls: Select Local > Maintenance > SNMP > SNMP Settings    Note: SNMP Settings can only be setup on the local terminal.
86  |  Configuring the Terminal   Aprisa XE User Manual  SNMP Access Controls  To add an access control: 1. Click  on  the  ‘Add  Read  Only’  button  to  enter  a  Read  Only  access  control  or  click  on  the  ‘Add Read/Write’ button to enter a Read/Write access control.    2. Enter the IP address of each SNMP manager allowed access to the terminal (read/write access control shown). The IP address entered must be a valid dot delimited IP address. Entering an IP address of ‘Any’ or * will allow any IP address access to the terminal.  3. Enter the community string for the access control. The Community string is usually different for Read Only and Read/Write operations. There is no default 'public' community string for an access control, but a 'public' community string can be entered which will have full MIB access, including the 4RF MIB.  4. Click Add.  To delete an access control: 1. Select the access control you want to delete and click Delete.    2. Click OK to delete the access control or Cancel to abort the delete.
 Configuring the Terminal  |  87  Aprisa XE User Manual  SNMP Trap Destinations To add a trap destination: 1. Click on the ‘Add SNMPv1’ button to enter a SNMPv1 trap destination or click on the ‘Add SNMPv2c’ button to enter a SNMPv2c trap destination. The differences between SNMPv1 and SNMPv2c are concerned with the protocol operations that can be performed. Selection of SNMPv1 and SNMPv2c must match the setup of the SNMP manager.    2. Enter  the  IP  address  of  the  server  to  which  you  want  SNMP  traps  sent  (SNMPv1  trap  destination shown). The IP address entered must be a valid dot delimited IP address.  3. Enter the community string for the trap destination. There is no default 'public' community string for a trap destination, but a 'public' community string can be entered.  4. Click Add.  To delete a trap destination: 1. Select the trap destination you want to delete and click Delete.    2. Click OK to delete the trap destination or Cancel to abort the delete.
88  |  Configuring the Terminal   Aprisa XE User Manual  Viewing the SNMP Traps Any  event  or  alarm  in  the  SNMP  objects  list  can  be  easily  viewed.  This  also  enables  you  to  verify,  if required, that SNMP traps are being sent. Select Local > Maintenance > SNMP > View Traps.    Viewing the SNMP MIB Details This is useful to see what MIB (Management Information Base) objects the terminal supports. Select Link or Local or Remote > Maintenance > SNMP > View MIB Details.
 Configuring the Terminal  |  89  Aprisa XE User Manual  Saving the Terminal's Configuration Note: To save cross connection configurations, see page 155.  To save a configuration: 1. Ensure you are logged in with either 'modify' or 'admin' privileges. 2. Select Local > Maintenance > Config Files > Save MIB. 3. Select the 'Save to disk' option in the dialog box that appears.  4. In the next dialog box that appears, navigate to the directory where you want to save the file, enter a suitable filename, and then click Save (The default name for this file is backupForm).  Note 1: If this dialog box does not appear, change your Internet security settings to allow downloads. You may also need to check your default download location. Note 2: Pop-ups must be enabled on you PC for this function to work (see ‘PC Settings for SuperVisor’ on page 50).  To load a configuration into a terminal:  Important:  Only  load  a  saved  configuration  file  to  another  terminal  that  has  exactly  the  same configuration (RF variant and interface cards).  1. Ensure you are logged in with either 'modify' or 'admin' privileges. 2. Select Local or Remote > Maintenance > Config Files > Load MIB.    3. Click Browse and then navigate to the file and select it. 4. Click Upload to load the configuration file into the terminal.
 Configuring the Traffic Interfaces  |  91  Aprisa XE User Manual  9. Configuring the Traffic Interfaces  Important:  When configuring a link, it is important that you configure the  remote terminal first as the new configuration may break the management connection to the remote terminal. Once  the  remote  terminal  has  been  configured,  the  local  terminal  should  be  configured to  match  the remote terminal.  Viewing a Summary of the Interfaces To view a summary of the interfaces fitted: Select Link or Local or Remote > Interface > Interface Summary.    The Interface Summary page shows:  The interface type for each slot that has been configured with the capacity used by each port.  Total Capacity. The total capacity of the radio link.  Ethernet Capacity. The capacity allocated to the Ethernet traffic over the radio link. This includes the user and management capacity assigned.  Management Capacity. The capacity allocated to the management conduit over ethernet.  Radio Capacity. The percentage of the total capacity of the radio link that has been allocated to traffic interfaces.  Drop and insert capacity. The percentage of the total drop and insert capacity used for local drop and insert cross connections. The total drop and insert capacity is 65536 kbit/s minus the assigned radio link capacity. Some interfaces also require extra bandwidth to be allocated to transport signalling, such as CTS / DTR handshaking  or  E&M  signals.  The  cross  connections  application  automatically  allocates  capacity  for signalling when it is needed.
92  |  Configuring the Traffic Interfaces   Aprisa XE User Manual  Configuring the Traffic Interfaces  Important: Before you can configure the traffic interfaces, the interface cards must be already installed (see ‘Installing Interface Cards’ on page 235).  Configuring each traffic interface involves the following steps (specific instructions for each interface card follow this page). First, specify the port settings for the Remote terminal: 1. Select  Remote  >  Interface  >  Interface  Summary,  select  the  interface  card  and  click  Configure Interface. 2. Select the port you want to configure and modify the settings, as necessary. 3. Click Apply to save the changes you have made.  Now specify the port settings for the Local terminal: 1. Select Local > Interface > Interface Summary, select the interface card and click Configure Interface. 2. Select the port you want to configure and modify the settings, as necessary. 3. Click Apply to save the changes you have made.  Once you have done this, you will need to configure the traffic cross-connects (see ‘Configuring the traffic cross connections’ on page 145) for each interface card.
 Configuring the Traffic Interfaces  |  93  Aprisa XE User Manual  Ethernet Switch In  the  default  mode,  the  Ethernet  switch  passes  IP  packets  (up  to  1522  bytes)  as  it  receives  them. However, using SuperVisor you can configure VLAN, QoS and port speed settings to improve how IP traffic is managed.  This  is  useful for operators  who  use  virtual  networks  to  segment  different  groups  of  users  or  different types of traffic in their network. These groups can be maintained across the radio link thus ensuring users in one virtual network cannot access data in other virtual networks.  The switch also has a high-speed address lookup engine, supporting up to 2048 preferential MAC addresses as well as automatic learning and aging. Traffic is filtered through this table and only traffic destined for the remote end is sent across the link improving bandwidth efficiency.  Note: You need ‘modify’ or ‘admin’ privileges to configure the Ethernet for VLAN and Quality of Service (QoS).  VLAN tagging By default, all user and management traffic is allocated the same VLAN across the link.  Alternatively, you can assign each of the four Ethernet ports to a VLAN. Each VLAN can be configured to carry  user  traffic,  or  user  traffic  and  radio  management  traffic.    The  VLAN  tagging  conforms  to  IEEE 802.1Q standard.
94  |  Configuring the Traffic Interfaces   Aprisa XE User Manual  Configuring the Ethernet switch for VLAN tagging 1. Select Link or Local or Remote > Interface > Ethernet Settings. Note: Always configure the remote terminal before the local terminal 2. In the Quick Links box at the bottom of the page, click Ethernet General Settings.  3. From  Ethernet  Grouping  drop-down  list  select  'Enabled'  ('Disabled'  is  the  default  setting;  Ethernet traffic is not segregated). Important: Changing this setting will disrupt Ethernet traffic.     4. Click Apply to apply changes or Reset to restore the previous configuration.  You now need to select the VLAN groups for each of the four Ethernet ports.
 Configuring the Traffic Interfaces  |  95  Aprisa XE User Manual  Specifying the VLAN ID for the Ethernet Ports Each Ethernet port can be configured with one of five VLAN IDs. You can configure each of the physical ports, numbered 1 to 4 with a VLAN ID (numbered User1 to User4 and User+Mgmt).  These VLAN IDs are applied at the ingress port and only used  internally across the link. The VLAN ID  is removed when traffic exits the switch at the egress port. Data entering the Ethernet switch on ports 1 to 4 or the internal management port can only exit on ports that are associated with the same VLAN ID as the ingress port.  For example, the physical RJ-45 port 1 may be on VLAN 3 at the local end, but at the remote end, the physical RJ-45 port 4 may be associated with VLAN 3. Traffic entering the local end on port 1 will exit the remote end on port 4. To allow the radio link to transport traffic using existing VLAN ID information, the radio adds an extra VLAN ID over the top of an existing VLAN ID (double-tagging). This extra VLAN ID is added at the ingress port  and  removed  at  the  egress  port.  This  adds  4  bytes  to  the  packet  and  the  maximum  packet  size supported by the radio is 1526 bytes. Note 1: Tagged flows can only have one port per VLAN ID on each terminal. Note 2: The ethernet switch only supports packets up to 1522 bytes in size at the ingress port.  1. Select Link or Local or Remote > Interface > Ethernet Settings. Note: Always configure the remote terminal before the local terminal 2. In the Quick Links box at the bottom of the page, select the port you want to configure:  3. The Ethernet Port Settings page appears for the port you selected:    4. From the Ethernet Group drop-down list, select the VLAN group to which you want this port to belong. Important: To access radio management traffic, you need to allocate one of the VLANs to ‘User and Management’. It is strongly recommended that you indicate which port or group of ports is associated to the management traffic first. 5. Click Apply. 6. Repeat steps 1-4 for the Ethernet switch in the other terminal in the link.
96  |  Configuring the Traffic Interfaces   Aprisa XE User Manual  Quality of Service Quality of Service (QoS) enables network operators to classify traffic passing through the Ethernet switch into prioritized flows. Each  port can have  a  priority  tag  set  at the ingress port, or  it can  be  read  directly  from the Ethernet traffic.  When  read  directly  from  the  Ethernet  traffic,  the  following  fields  are  used  to  determine  the traffic’s QoS priority.   The IEEE 802.1p Priority information in the IEEE 802.3ac Tag.  The IPv4 Type of Service field.  The IPv6 Traffic Class field.  You can select one of two queuing methods:  IEEE 802.1p standard method  Cisco-proprietary method The queuing method determines how the traffic is prioritized. Each port has four egress queues (queues 0-3) of differing priorities. Queue 0 is the lowest priority and Queue 3 is the highest priority.  Configuring the Ethernet Switch for QoS 1. Select Link or Local or Remote > Interface > Ethernet Settings. 2. In the Quick Links box at the bottom of the page, click Ethernet General Settings.   The Ethernet General Settings page:    3. Leave Ethernet Grouping set to 'Disabled' (unless you want to enable VLAN tagging).
 Configuring the Traffic Interfaces  |  97  Aprisa XE User Manual  4. Select the Priority Queue Scheduling.  There are two methods for transmitting the Ethernet traffic queues across the link:  Strict: the queue is transmitted based on the priority. The first queue transmitted is the highest priority queue and the terminal will not transmit any other traffic from any other queue until the highest priority queue is empty. Then the next highest priority queue is transmitted, and so on.  Weighted (default): each of the queues will transmit a number of packets based on a weighting. The following table shows how the weighting is applied to each queue.  Queue Priority Number of packets transmitted Queue 3 Highest Priority 8 packets Queue 2  4 packets Queue 1  2 packets Queue 0 Lowest Priority 1 packets  5. Select the IEEE 802.1 Priority Queue Mapping.  This  determines  the  standard  (or  scheme)  used  for  prioritizing  traffic  into  one  of  four  queues numbered 0 to 3 (3 being the highest priority queue). There are  two  possible  methods  for  queuing  the  ethernet  traffic.  One  is  based on  the IEEE  802.1D standard (which is the default setting), and the other is based on the Cisco-proprietary method.  The following table shows how traffic is queued using the two methods:    Output Queue Priority Traffic Type Cisco Priority Queuing IEEE 802.1D Priority Queuing 0 (default) Best Effort 0 1 1 Background 0 0 2 Spare 1 0 3 Excellent Effort 1 1 4 Controlled Load 2 2 5 ‘Video’ < 100ms latency and jitter 2 2 6 ‘Video’ < 10ms latency and jitter 3 3 7 Network Control 3 3
98  |  Configuring the Traffic Interfaces   Aprisa XE User Manual  Configuring the Ethernet Ports for QoS Each Ethernet port can be configured for Ingress Rates and Priority queues.  To configure the Ethernet ports for QoS: 1. Select Link or Local or Remote > Interface > Ethernet Settings.    2. Select the port you want to configure and click Port Configuration.
 Configuring the Traffic Interfaces  |  99  Aprisa XE User Manual  3. Select the required Ingress Rate for this port. The ingress  rate (input data rate) limits the rate that traffic is  passed  into the port. Operators can protect the terminal’s traffic buffers against flooding by rate-limiting each port.  Ingress Rate  Unlimited Default 128 kbit/s  256 kbit/s  512 kbit/s  1 Mbit/s  2 Mbit/s  4 Mbit/s  8 Mbit/s   4. Select the Priority for all Ethernet data entering this port. The priority specifies where the priority control information is sourced from. From Frames Traffic is prioritized into one of the following traffic types (numbered 0 to 7) by the originating device or application. Generally, the higher the priority, the higher the priority rating. However, in the IEEE standard queuing scheme, the ordering of the priority is 1, 2, 0, 3, 4, 5, 6, 7. In this case 0 has a higher priority than 1 and 2.  If priority control information is present in the Ethernet header, this information is used to priorities the traffic but if there is no priority control information in the Ethernet header, the IP header is used to priorities the traffic.  Low, Medium, High, Very High The  priority  rating  you  select  is  applied  to  all  traffic  on  the  port  and  is  applied  to  all  traffic irrespective of traffic type and the priority control information in the traffic.  5. Click Apply to apply changes or Reset to restore the previous configuration.
100  |  Configuring the Traffic Interfaces   Aprisa XE User Manual  Viewing the Status of the Ethernet Ports Select Link or Local or Remote > Interface > Switch Summary.    For each port the following is shown:  Speed — the data rate (in Mbit/s) of the port.  Duplex — whether half or full duplex.  Status — whether there is a cable plugged into the port (active) or not (inactive). Note:  The  Ethernet ports on  the  terminal are set to  auto-configure  the  speed and  duplex for the best performance.  Resetting the Ethernet Settings You can easily reset the VLAN and QoS settings to the default values, if required. This is useful if you want the  Ethernet  switch  to  operate  in  the  default  mode,  that  is,  IP  packets  are  passed  across  the  link  as received. Note: You can also do this using the Setup menu (see page 57.).  1. Select Link or Local or Remote > Interface > Default Ethernet Settings.    Set Ethernet Groupings To Default Values.  This  resets  the  Ethernet  Grouping  setting  to  'Disabled',  which  means  that  the  Ethernet  switch  no longer  operates  as  a  VLAN.  In  addition,  all  the  Ethernet  ports  will  default  to  the  'User  and Management' Ethernet Group.  Set Ethernet QoS To Default Values.  This  resets  the  ingress  rate  for  all  the  ports  to  'Unlimited'  and  the  priority  to  'From  Frames'.  In addition,  the  Ethernet  QoS  settings are  reset  to  the  defaults:  Priority  Queue Scheduling reverts  to 'Weighted' and IEEE 802.1 Priority Queue Mapping reverts to 'IEEE Standard'.  2. Click Apply to apply changes or Reset to restore the previous configuration.
 Configuring the Traffic Interfaces  |  101  Aprisa XE User Manual  Ethernet Port Startup In previous Aprisa XE software versions, the Ethernet switch ports where enabled when the radio powered up. In software version 8.6.53, the mode of operation was changed to disable the Ethernet switch ports until the radio software has completed booting. This enhancement has  been implemented to meet customer requirements.  A  hardware  modification  is  required  to  the  Aprisa  XE  motherboard to  enable  this  enhancement  (0 ohm resistor fitted).     If the Aprisa XE motherboard hardware modification has been done, the Aprisa XE software version 8.6.53 or greater will be required to operate the radio. If Aprisa XE software prior to this version is used, the Ethernet ports will not enable. For this reason, an Aprisa XE  running software version 8.6.53 cannot be downgraded to an earlier software version.
102  |  Configuring the Traffic Interfaces   Aprisa XE User Manual  QJET Port Settings 1. Select Link or Local or Remote > Interface > Interface Summary, then select the QJET interface and click Configure Interface.    2. Select the QJET port to be configured and click Edit.    3. Set the QJET Line Encoding: For an E1 port, set the E1 Line Encoding as required to either HDB3 or AMI. The default is HDB3. For a T1 port, set the T1 Line Encoding as required to either B8ZS or AMI. The default is B8ZS.
 Configuring the Traffic Interfaces  |  103  Aprisa XE User Manual  4. Set the QJET T1 Tx Waveform Shaper (T1 only). The Tx Waveform Shaper applies 1/√f pre-emphasis to the transmit waveform to ensure the waveform meets the G.703 pulse mask at the interconnect point. Waveform shaping assumes the use of 22 gauge (0.32 mm2) twisted-pair cable. The default is 0 ~  133 f t .  Cable Length Range  0 ~  133 f t  Def au lt  133 ~  266 f t   266 ~  399 f t   399 ~  533 f t   533 ~  655 f t    5. Loopback controls the port loopbacks (see ‘Interface Loopbacks’ on page 242).  Setting Function Off No port loopback Line Facing Port traffic from the customer is transmitted over the RF link but is also looped back to the customer Radio Facing Traffic received from the RF link is passed to the customer port but is also looped back to be transmitted over the RF link  Note: The QJET E1 / T1 port green LED flashes when the loopback is active.  6. AIS Hysteresis sets the number of seconds after a Modem LOS that AIS is sent.  7. Click Apply to apply changes or Reset to restore the previous configuration.
104  |  Configuring the Traffic Interfaces   Aprisa XE User Manual  Q4EM Port Settings 1. Select Link or Local or Remote > Interface > Interface Summary, select the Q4EM interface, and click Configure Interface.    2. Select the Q4EM port to be configured, and click Edit.    'Slot' shows the slot the Q4EM interface card is plugged into in the terminal (A – H). 'Port' shows the interface port number (1-4). ‘PCM Mode’ shows the current mode assigned to the port by the cross connect. ‘E&M’ shows if the E&M signalling on the port has been activated by the cross connect. ‘Loopback’ controls the 4 wire analogue port loopbacks.
 Configuring the Traffic Interfaces  |  105  Aprisa XE User Manual  3. Set the Q4EM Output level and the Input level required.  Signal Direction Level adjustment range Default setting Input level (Li) -14.0 dBr to +4.0 dBr in 0.5 dB steps +0.0 dBr Output level (Lo) -14.0 dBr to +4.0 dBr in 0.5 dB steps +0.0 dBr  It is important that analogue signals presented from the Q4EM interface be normalized to fit within the ± 127  quantizing  steps  of  the  encoder.  This is  done  by  adjusting the circuit levels  relative  to the  0  dBm (± 118 peak code) for example:  If a nominal input level of -6.0 dBm is applied to the Q4EM interface input port, the Q4EM Input Level must be set to -6.0 dBr. This will effectively amplify the sent signal by 6.0 dB to produce a digital signal with a ± 118 peak code (0 dBm).  If a nominal output level of -6.0 dBm is required from the Q4EM interface output port, the Q4EM Output Level must be set to -6.0 dBr. This will effectively attenuate the received decoded signal by 6 dB.  4. Set the Q4EM E wire interface to either Normal or Inverted. This determines the state of the CAS bit relative to the state of the E wire:  E wire output CAS bit Normal (default) CAS bit Inverted Output Active 0 1 Output Inactive 1 0  5. Set the Q4EM M wire interface to either Normal or Inverted. This determines the state of the CAS bit relative to the state of the M wire:  M wire input CAS bit Normal (default) CAS bit Inverted Input Active 0 1 Input Inactive 1 0  6. Click Apply to apply changes or Reset to restore the previous configuration. 7. Select Q4EM PCM Law Control from the Quick Links box. This option sets the companding law used by the four ports on the Q4EM card.     A-Law is used internationally (default).  µ-Law is used in North America and Japan. Note: The PCM Law Control controls all four ports on the Q4EM card. To run a mixture of µ-Law and A-Law interfaces, multiple Q4EM cards are necessary.
106  |  Configuring the Traffic Interfaces   Aprisa XE User Manual  8. Loopback controls the port loopbacks (see ‘Interface Loopbacks’ on page 242).  Setting Function Off No port loopback Line Facing Port traffic from the customer is transmitted over the RF link but is also looped back to the customer Radio Facing Traffic received from the RF link is passed to the customer port but is also looped back to be transmitted over the RF link
 Configuring the Traffic Interfaces  |  107  Aprisa XE User Manual  Loop Interface Circuits  DFXO / DFXS Loop Interface Circuits Function The function of DFXO / DFXS 2 wire loop interface circuits is to transparently extend the 2 wire interface from the exchange line card to the telephone / PBX, ideally without loss or distortion. The DFXO interface simulates the function of a telephone and a DFXS interface simulates the function of an exchange line card. These circuits are known as ‘ring out, dial in’ 2 wire loop interface circuits. Network Performance The overall Network Performance is dependant on the number of D-A and A-D conversions and 2 wire to 4 wire / 4 wire to 2 wire conversions in the end to end circuit (telephone to telephone). To achieve the best overall Network Performance, the number of D-A and A-D conversions and 2 wire to 4 wire / 4 wire to 2 wire conversions should be minimized. Circuit Performance The  circuit  quality  achieved  with  a  2  wire  voice  circuit  is  very  dependant  on  the  external  interface parameters and the interconnecting copper line. Short interconnecting  copper lines  (<  100 meters),  have  little  effect on  the circuit  performance  so  the interface parameters have the dominant affect on circuit performance. As  the  length  of  the  interconnecting  copper  line  is  increased,  the  attenuation  of  the  analogue  signal degrades circuit performance but also the impedance of the copper line also has a greater effect on the circuit performance. For this reason, complex line impedance networks (e.g. TBR21, TN12) were created which model the average impedance of the copper network. The factors that affect the quality of the circuit achieved are; DFXO interface  The  degree  of  match  between  the  DFXO  line  termination  impedance,  the  impedance  of  the interconnecting copper line and the exchange line card line termination impedance. This affects the return loss.  The  degree  of  match  between  the  DFXO  line  termination  impedance,  the  impedance  of  the interconnecting copper line and the  exchange line  card  hybrid balance  impedance.  This  affects the exchange line card transhybrid balance.  The  degree  of  match  between  the  DFXO  hybrid  balance  impedance,  the  impedance  of  the interconnecting copper line and the exchange line card line termination impedance. This affects the DFXO transhybrid balance.  The circuit levels of both the DFXO and the exchange line card. DFXS interface  The  degree  of  match  between  the  DFXS  line  termination  impedance,  the  impedance  of  the interconnecting copper line and the telephone line termination impedance. This affects the return loss.  The  degree  of  match  between  the  DFXS  line  termination  impedance,  the  impedance  of  the interconnecting  copper  line  and  the  telephone  hybrid  balance  impedance.  This  affects  the telephone transhybrid balance.  The  degree  of  match  between  the  DFXS  hybrid  balance  impedance,  the  impedance  of  the interconnecting copper line and the telephone line termination impedance. This affects the DFXS transhybrid balance.  The circuit levels of both the DFXS and the telephone.
108  |  Configuring the Traffic Interfaces   Aprisa XE User Manual  Line Termination Impedance The line termination impedance (Zt) is the impedance seen looking into the DFXO or DFXS interface. The line termination impedance is not the same as the hybrid balance impedance network (Zb) but can be set to the same value. Changing  the  DFXO  /  DFXS  impedance  setting  on  the  Aprisa  XE  changes  both  the  line  termination impedance and the hybrid balance impedance to the same value.  Hybrid Balance Impedance The hybrid balance impedance (Zb) is the impedance network on the opposite side of the hybrid from the DFXO  /  DFXS  line  interface.  The  purpose  of  this  network  is  to  balance  the  hybrid  to  the  impedance presented to the DFXO / DFXS line interface. Changing  the  DFXO  /  DFXS  impedance  setting  on  the  Aprisa  XE  changes  both  the  line  termination impedance and the hybrid balance impedance to the same value.  Transhybrid loss Transhybrid loss is a measure of how much analogue signal received from the remote terminal is passed across the hybrid and sent to the remote terminal. The transhybrid loss is maximized when the hybrid balance impedance matches the impedance presented to the DFXO / DFXS line interface. An optimized hybrid minimizes circuit echo.
 Configuring the Traffic Interfaces  |  109  Aprisa XE User Manual  Circuit Levels The 8 bit digital word for each analogue sample encoded (A law), has a maximum of 255 quantizing code steps, a maximum of + 127 for positive signals and a minimum of - 127 for negative signals. No signal is represented by the code step 0. A nominal level of 0 dBm generates a peak code of ± 118 which allows up to + 3.14 dBm0 of headroom before  the  maximum  step  of  127  is  obtained.  Any  level  greater  than  + 3.14  dBm0  will  be  distorted (clipped) which will cause severe problems with analogue data transmission. It  is  therefore  important  that  analogue  signals  presented  from  the  DFXO  /  DFXS  line  interface  be normalized to fit within the ± 127 quantizing steps of the encoder. This is done by adjusting the circuit levels relative to the 0 dBm (± 118 peak code) for example:  If a nominal input level of +1 dBm is applied to the DFXS line interface, the DFXS Input Level must be  set  to  +1.0  dBr.  This  will  effectively  attenuate the sent  signal  by  1  dB  to  produce  a  digital signal with a 118 peak code (0 dBm).  If a nominal output level of -6 dBm is required from the DFXS line interface, the DFXS Output Level must be set to -6.0 dBr. This will effectively attenuate the received signal by 6 dB.  The circuit levels and the transhybrid loss of both ends of the circuit, also determine the stability of the circuit. If the circuit levels are too high and the transhybrid loss figures achieved are too low, the circuit can have a positive loop gain and can recirculate (sometimes called singing). Typically,  an  end  to  end  2  wire voice circuit  is engineered  to  have  a  2-3  dB  loss  in  both  directions of transmission.  2WS2WR 2WS input2WR output0 dBr -6.0 dBr+1.0 dBr-8.0 dBm+1.0 dBm-2.0 dBm0 dBr0.0 dBm-4.0 dBr-1.0 dBr-6.0 dBmDFXSInterfaceDFXOInterface2WS2WR-6.0 dBr+1.0 dBr-1.0 dBm0 dBr0.0 dBm0 dBr-2.0 dBmExchangeLine CardAprisa XEOverall Loss = 3.0 dBOverall Loss = 8.0 dBDerived System Level PlanNote 1: The derived system loss is 2 dB in both directions due to the deliberate 2 dB level mismatch betweenthe exchange line card and the DFXO interface unitZBZBZBTransmissionReference Point4WR4WS4WR4WS4WR4WS
110  |  Configuring the Traffic Interfaces   Aprisa XE User Manual  E1 CAS to DFXS Circuits Function E1 CAS to DFXS circuits can be provisioned over an Aprisa XE link by using a DFXS interface card at the customer end of the link and a QJET at the exchange end of the link. The QJET E1 interface connects to an exchange or PBX Digital Trunk Interface (DTI) to provide FXS foreign exchange circuits. The Aprisa XE can interconnect at E1 to an exchange / PBX DTI if the DTI is capable of providing standard 1 bit channel associated signalling (CAS).  Forward Af Backward Ab Idle 1 Idle 1 Ringing 0 Loop (Off hook) 0  The signalling functions provided with a 1 bit CAS protocol are:  Ring cadence transmission  Ring trip   Off hook   Switch hook flash   Decadic dialling  The speech path functions as normal and provides:  Transmission of tones (e.g. dial tone, ring tone)  Caller ID  DTMF dialling   Speech  Setup Cross connect the voice channel between the QJET and the DFXS card. Cross connect the signalling (A bit only) using ‘4 wire compatible’ mode between the QJET and the DFXS card. Configure the E1 spare CAS bits to be compatible with the DTI (see ‘QJET Spare CAS Bit Control’ on page 165). The standard spare bit states are B = 1, C = 0, D = 1.  DFXS to DFXS Hotline Circuits Function A ‘Hotline’ circuit can be provisioned over an Aprisa XE link by using a DFXS interface card at both ends of the link. When one phone goes off hook, the other phone rings and vice versa. A 1 bit CAS protocol is used to signal between the DFXS interfaces:  Forward Af Backward Ab Idle 1 Idle 1 Ringing 0 Loop (Off hook) 0  Setup
 Configuring the Traffic Interfaces  |  111  Aprisa XE User Manual  Cross connect the voice channel on both DFXS cards. Cross connect the signalling (A bit only) using ‘4 wire compatible’ mode on both DFXS cards.
112  |  Configuring the Traffic Interfaces   Aprisa XE User Manual  DFXS Port Settings 1. Select Link or Local or Remote > Interface > Interface Summary, then select the DFXS interface and click Configure Interface.    2. Select the DFXS port to configure, and click Edit.    'Slot' shows the slot the DFXS interface card is plugged into in the terminal (A – H). 'Port' shows the interface port number (1-2). ‘PCM Mode’ shows the current mode assigned to the port by the cross connect. ‘Loopback’ loops back the port digital paths to return the port analogue signal back to the customer. ‘Path  Mute’ mutes the  TX  or  RX  digital  path.  This function  is  used to  mute the return  direction of transmission  during  A-A  intrinsic  performance  testing  as  recommended  in  ITU  G.712  para  1.2  Port definitions.  Path Mute Description  No Mute Normal signal transmission in both directions Default Mute TX Mutes the transmit digital path i.e. the signal from the DFXS to the DFXO is muted  Mute RX Mutes the receive digital path i.e. the signal from the DFXO to the DFXS is muted
 Configuring the Traffic Interfaces  |  113  Aprisa XE User Manual  3. Set the DFXS Input Level and the Output Level required:  Signal Direction Level adjustment range Default setting Input Level (Li) -9.0 dBr to +3.0 dBr in 0.5 dB steps +1.0 dBr Output Level (Lo) -9.5 dBr to +2.5 dBr in 0.5 dB steps -6.0 dBr  In the example shown below, the Customer Premises Equipment is a telephone connected to a DFXS card. The levels are set based on the system using a 0 dBr transmission reference point.    DFXS Input Level setting The  telephone  has  a  nominal  output  level  of  +1  dBr.  To  achieve  a  transmission  reference  point transmit level of 0 dBr, the DFXS Input Level is set to +1 dBr (effective T pad loss of 1 dB). DFXS Output Level setting The telephone has a nominal input level of -6 dBr. With a transmission reference point received level of 0 dBr, the DFXS Output level is set to -6 dBr (effective R pad loss of 6 dB).  4. Click Apply to apply changes or Reset to restore the previous configuration.
114  |  Configuring the Traffic Interfaces   Aprisa XE User Manual  5. Select the DFXS Control. The DFXS Control page sets values for both ports on the DFXS card. The cards are shipped with the default values shown in the illustration below:    'Slot' shows the slot the DFXS interface card is plugged into in the terminal (A – H).  6. Select the DFXS PCM Law. This option sets the companding law used by both ports on the DFXS card.  A-Law is used internationally (default)  µ-Law is used in North America and Japan.  Note: To run a mixture of µ-Law and A-Law interfaces, multiple DFXS cards are necessary.
 Configuring the Traffic Interfaces  |  115  Aprisa XE User Manual  7. Select the DFXS Line Impedance This option sets the DFXS line termination impedance and the hybrid balance impedance to the same value.  Selection Description  600 Ω Standard equipment impedance Default 600 Ω + 2.16 uF Standard equipment impedance with low frequency roll-off  900 Ω Typically used on loaded cable pairs  900 Ω + 2.16 uF Typically used on loaded cable pairs with low frequency roll-off  TN12 Standard complex impedance for Australia  TBR21 Widely deployed complex impedance  BT3 Standard complex impedance for New Zealand    On a short line (< 100 meters), the selected impedance should match the impedance of the phone (off-hook).  On a long line (> 1000 meters), the selected impedance should match the impedance of the phone (off-hook) as seen through the line.  If  you  are not  sure  what  the  expected  impedance value  should  be,  check  with  the  CPE  equipment supplier.  8. Set the DFXS Transhybrid Balance (usually not required to change). The  default  Transhybrid  Balance  value  (0  dB),  provides  the  best  circuit  performance  where  the balance impedance (set by the Line Impedance setting) matches the impedance of the line. You  should  only  adjust  the  transhybrid  balance  when  the  balance  impedance  does  not  match  the actual line impedance. You can achieve small circuit improvements using this option.  9. Set the DFXS Ringer Frequency. This option sets the DFXS Ringing Frequency.  Selection Description  17 Hz Used in older networks  25 Hz Standard ringing frequency Default 50 Hz Used by some telephone exchanges
116  |  Configuring the Traffic Interfaces   Aprisa XE User Manual  10. Set the DFXS Ringer Output Voltage. This option sets the DFXS open circuit Ringing Output Voltage which is sourced via an internal ringing resistance of 178  per port. The DC offset on the AC ringing signal enables ring trip to occur with a DC loop either during ringing cycles. The normal DC line feed voltage enables ring trip to occur with a DC loop in the silent period between the ringing cycles.  Selection Description  60 Vrms + 0 VDC Outputs 60 VRMS ringing with no DC offset Maximum ringing voltage for high ringing load applications but no DC ring trip  55 Vrms + 10 VDC Outputs 55 VRMS ringing with a 10 VDC offset Medium ringing load applications  50 Vrms + 18 VDC Outputs 50 VRMS ringing with a 18 VDC offset Above average ringing load applications  45 Vrms + 22 VDC Outputs 45 VRMS ringing with a 22 VDC offset Typical application Default 40 Vrms + 24 VDC Outputs 40 VRMS ringing with a 24 VDC offset Lowest terminal power consumption   11. Select the DFXS Billing Tone Frequency. This  option  sets  the  frequency  of  billing  tone  generation.  If  you  are  not  sure  what  the  expected frequency of the billing tone should be, check with the exchange equipment supplier.  Selection Description  12 kHz Use if the CPE requires a 12 kHz billing tone signal  16 kHz Use if the CPE requires a 16 kHz billing tone signal Default
 Configuring the Traffic Interfaces  |  117  Aprisa XE User Manual  12. Select the DFXS Billing Tone Level. This option sets the DFXS billing tone output level which is defined as the voltage into 200 Ω with a source impedance equal to the Line Impedance setting. The billing tone voltage into 200 Ω is limited by the maximum open circuit voltage of 1 Vrms. The drop down list reflects the maximum allowable billing tone output voltage for the Line Impedance setting selected.  Selection Description  400 mV rms Billing tone voltage setting available for line impedances of TN12, BT3 and TBR21.  300 mV rms Billing tone voltage setting available for line impedances of TN12, BT3, TBR21 and 600 Ω. Default 200 mV rms Billing tone voltage setting available for line impedances of TN12, BT3, TBR21, 600 Ω and 900 Ω.  100 mV rms Billing tone voltage setting available for all line impedance settings.   13. The  DFXS  billing  tone Attack  Ramp  time can  be adjusted  to  reduce the  interference  which can  be produced when a signal turns on quickly. The attack ramp time is how long the billing tone generator takes to ramp up to full level when it is turned. The default ramp time is 1 ms.
118  |  Configuring the Traffic Interfaces   Aprisa XE User Manual  14. The DFXS Signalling Advanced options are used to control the four CAS bits ABCD in the DFXO to DFXS direction of transmission and one CAS bit A in the DFXS to DFXO direction of transmission. This option sets the signalling for both DFXS card ports. Transparent Normal mode is used for normal traffic and Transparent Inverted mode can be used for special signalling requirements when a function needs to be reversed e.g. to change the idle polarity of the DFXS line feed voltage. Forced modes are used to disable particular functions e.g. when polarity reversals are not required. They can also be used for system testing e.g. to apply DFXS continuous ringing output    Selection Description  Transparent Normal Normal transparent transmission of the CAS bit  Default Transparent Inverted Transparent transmission of the CAS bit but inverts the polarity.  Forced Normal Sets the CAS bit to 1 (inactive).  Forced Inverted Sets the CAS bit to 0 (active).   DFXO to DFXS CAS Bit Forced Normal Forced Inverted A bit (fault) Sets the CAS A bit to 1 continuous fault state Sets the CAS A bit to 0 no fault state B bit (ring) Sets the CAS B bit to 1 no DFXS ringing output. Sets the CAS B bit to 0 continuous DFXS ringing output. C bit (billing) Sets the CAS C bit to 1 no DFXS billing tone output. Sets the CAS C bit to 0 continuous DFXS billing tone output. D bit (reversal) Sets the CAS D bit to 1 no DFXS polarity reversal Sets the CAS D bit to 0 continuous DFXS polarity reversal From DFXS to DFXO CAS Bit Forced Normal Forced Inverted A bit (off hook) Sets the CAS A bit to 1 no DFXO off hook Sets the CAS A bit to 0 continuous DFXO off hook
 Configuring the Traffic Interfaces  |  119  Aprisa XE User Manual  QJET to DFXS CAS Bit Forced Normal Forced Inverted A bit (ring) Sets the CAS A bit to 1 no DFXS ringing output. Sets the CAS A bit to 0 continuous DFXS ringing output. B bit (na) Not Applicable Not Applicable C bit (na) Not Applicable Not Applicable D bit (na) Not Applicable Not Applicable From DFXS to QJET CAS Bit Forced Normal Forced Inverted A bit (off hook) Sets the CAS A bit to 1 Idle state to E1 port Sets the CAS A bit to 0 Off hook state to E1 port  15. Click Apply to apply changes or Reset to restore the previous configuration.
120  |  Configuring the Traffic Interfaces   Aprisa XE User Manual  DFXO Port Settings  1. Select Link or Local or Remote > Interface > Interface Summary, then select the DFXO interface and click Configure Interface.    2. Select the DFXO port to configure, and click Edit.    'Slot' shows the slot the DFXO interface card is plugged into in the terminal (A – H). 'Port' shows the interface port number (1-2). ‘PCM Mode’ shows the current mode assigned to the port by the cross connect. ‘Loopback’ loops back the port digital paths to return the port analogue signal back to the customer.
 Configuring the Traffic Interfaces  |  121  Aprisa XE User Manual  3. Set the DFXO Input Level and the Output Level required:  Signal Direction Level adjustment range Default setting Input Level (Li) -10.0 dBr to +1.0 dBr in 0.5 dB steps -4.0 dBr Output Level (Lo) -10.0 dBr to +1.0 dBr in 0.5 dB steps -1.0 dBr  In the example shown below, the PSTN exchange line card is connected to a DFXO card. The levels are set based on the system using a 0 dBr transmission reference point.     DFXO Input Level setting The  exchange  line  card has  a  nominal  output  level  of  -6  dBr.  To  achieve  a  digital  reference  point transmit level of -2.0 dBm0, the DFXO input level is set to -4.0 dBr (effective T pad gain of 4.0 dB). The deliberate 2 dB of loss between the exchange line card and the DFXO provides a 2 dB of overall circuit loss between the DFXO and the DFXS.  DFXO Output Level setting The  exchange  line  card  has  a  nominal input  level of  +1.0  dBr.  With  a  transmission  reference  point received level of -2.0 dBm0, the DFXO output level is set to -1.0 dBr (effective R pad loss of 1.0 dB). The deliberate 2 dB of loss between the exchange line card and the DFXO provides a 2 dB of overall circuit loss between the DFXS and the DFXO.   4. Click Apply to apply changes or Reset to restore the previous configuration.
122  |  Configuring the Traffic Interfaces   Aprisa XE User Manual  5. Select the DFXO Control. The DFXO Control page sets values for both ports on the DFXO card. The cards are shipped with the default values shown in the illustration below:    'Slot' shows the slot the DFXO interface card is plugged into in the terminal (A – H). 6. Select the DFXO PCM Law. This option sets the companding law used by both ports on the DFXO card.  A-Law is used internationally (default)  µ-Law is used in North America and Japan.  Note: To run a mixture of µ-Law and A-Law interfaces, multiple DFXO cards are necessary.
 Configuring the Traffic Interfaces  |  123  Aprisa XE User Manual  7. Select the DFXO Impedance This option sets the DFXO line termination impedance and the hybrid balance impedance to the same value. Selection Description  600 Ω Standard equipment impedance Default 600 Ω + 2.16 uF Standard equipment impedance with low frequency roll-off  900 Ω Typically used on loaded cable pairs  900 Ω + 2.16 uF Typically used on loaded cable pairs with low frequency roll-off  TN12 Standard complex impedance for Australia  TBR21 Widely deployed complex impedance  BT3 Standard complex impedance for New Zealand  BT Network Standard complex impedance for UK  China Standard complex impedance for China   On  a  short  line  (<  100  metres),  the  selected  impedance  should  match  the  impedance  of  the exchange line card.  On  a  long  line  (>  1000  metres),  the  selected  impedance  should  match  the  impedance  of  the exchange line card as seen through the line. If  you  are  not  sure  what  the  expected  impedance  value  should  be,  check  with  the  exchange equipment supplier.  8. Enable the DFXO Echo Canceller if required. The DFXO Echo Canceller provides up to 64 ms of echo cancellation. This feature is only available on Rev D (and later) DFXO cards. Analogue data devices e.g. modems send a disable signal to disable any echo canceller in circuit while it trains its own echo canceller. There are two possible disable signals. ITU G.164 specifies a disable signal of a single 2100 Hz tone and ITU G.165 specifies a disable signal of 2100 Hz tone with phase reversals every 450 ms.  Selection Description  Off No echo canceller operation. Default On Echo canceller operational but without disabling.  Auto Disable G.164 Echo canceller operational with automatic disabling using ITU G.164 2100 Hz tone.  Auto Disable G.165 Echo canceller operational with automatic disabling using ITU G.165 2100 Hz tone with phase reversals every 450 ms.
124  |  Configuring the Traffic Interfaces   Aprisa XE User Manual  9. Set the DFXO Loop Current Limiter. This option turns on a current limiter which limits the maximum current that can be drawn from the exchange line card by the DFXO interface.  As a general rule, only one interface should current limit so if the exchange interface current limits, the DFXO interface should be set to current limit off.  Selection Description  Off Use if the exchange line interface uses current limiting. Default On (60 mA) Use if the exchange line interface does not use current limiting. The DFXO limits the line loop current to 60 mA.   Note:  The  DFXO  provides an  early  warning over  current  alarm  ‘fxoCurrentOvld’  if  the  loop  current exceeds 100 mA for 2 seconds. This alarm clears when the loop current is less than 90 mA. The DFXO also provides an over current safety shut down limit which removes its line loop if the loop current exceeds 160 mA.  10. Select the DFXO Billing Tone Frequency. This  option  sets  the  frequency  of  billing  tone  detection.  If  you  are  not  sure  what  the  expected frequency of the billing tone should be, check with the exchange equipment supplier. Selection Description  12 kHz Use if the exchange outputs 12 kHz billing tone  16 kHz Use if the exchange outputs 16 kHz billing tone Default  11. The DFXO Billing Tone Advanced sets the billing tone Bandwidth and the billing tone Level Sensitivity.    The DFXO billing tone Bandwidth determines the bandwidth of the band pass filter that is used by the billing tone detector in terms of +/- % of the billing tone frequency. The adjustment range is +/- 1.5% to +/- 7.5% and the default value is +/- 5.0%.  The DFXO billing tone Level Sensitivity determines the DFXO detection sensitivity.The adjustment range is 0 dB (metering detection threshold of -17 dBm measured across 200  ) to 27 dB (metering detection threshold of  -40 dBm measured across 200  ) in 1 dB  steps and the default value is 0 dB.
 Configuring the Traffic Interfaces  |  125  Aprisa XE User Manual  12. Select the DFXO On Hook Speed.  This option sets the slope of the transition between off-hook and on-hook. Selection Description  < 500 μs Off-hook to on-hook slope of < 500 μs Default 3 ms Off-hook to on-hook slope of 3 ms ± 10% that meets ETSI standard  25 ms Off-hook to on-hook slope of 25 ms± 10% used to reduce transient interference in copper cable   13. Select the DFXO ringer Impedance.  This option sets the DFXO ringing input impedance as seen by a sine wave ringing signal applied to the DFXO 2 wire port at the frequency of ringing. Selection Description  > 1 M  DFXO input impedance to ringing of > 1 M  Default > 12 kΩ DFXO input impedance to ringing of > 12 kΩ   14. Select the DFXO ringer Detection Threshold.  This option sets the DFXO ringing detect threshold.  Selection Description  16 Vrms DFXO detects ringing voltages of 16 Vrms or greater (does not detect ringing below 13 Vrms) Default 26 Vrms DFXO detects ringing voltages of 26 Vrms or greater (does not detect ringing below 19 Vrms)  49 Vrms DFXO detects ringing voltages of 49 Vrms or greater (does not detect ringing below 40 Vrms)   It is recommended that the ringer Detection Threshold be set to 49 Vrms if a DFXO ringer impedance of > 12 kΩ is selected.  Note: The Signalling Mode is set in the Cross Connections application (see page 171).
126  |  Configuring the Traffic Interfaces   Aprisa XE User Manual  15. The DFXO Signalling Advanced options are used to control the four CAS bits ABCD in the DFXO to DFXS direction of transmission and one CAS bit A in the DFXS to DFXO direction of transmission. This option sets the signalling for both DFXO card ports. Transparent Normal mode is used for normal traffic and Transparent Inverted mode can be used for special signalling requirements when a function needs to be reversed e.g. to change the idle polarity of the DFXS line feed voltage. Forced modes are used to disable particular functions e.g. when polarity reversals are not required. They can also be used for system testing e.g. to apply DFXO continuous off hook    Selection Description  Transparent Normal Normal transparent transmission of the CAS bit  Default Transparent Inverted Transparent transmission of the CAS bit but inverts the polarity.  Forced Normal Sets the CAS bit to 1.  Forced Inverted Sets the CAS bit to 0.   From DFXO to DFXS CAS Bit Forced Normal Forced Inverted A bit (fault) Sets the CAS A bit to 1 continuous fault state Sets the CAS A bit to 0 no fault state B bit (ring) Sets the CAS B bit to 1 no DFXS ringing output. Sets the CAS B bit to 0 continuous DFXS ringing output. C bit (billing) Sets the CAS C bit to 1 no DFXS billing tone output. Sets the CAS C bit to 0 continuous DFXS billing tone output. D bit (reversal) Sets the CAS D bit to 1 no DFXS polarity reversal Sets the CAS D bit to 0 continuous DFXS polarity reversal DFXS to DFXO CAS Bit Forced Normal Forced Inverted A bit (off hook) Sets the CAS A bit to 1 no DFXO off hook Sets the CAS A bit to 0 continuous DFXO off hook
 Configuring the Traffic Interfaces  |  127  Aprisa XE User Manual  QJET to DFXS CAS Bit Forced Normal Forced Inverted A bit (ring) Sets the CAS A bit to 1 no DFXS ringing output. Sets the CAS A bit to 0 continuous DFXS ringing output. B bit (na) Not Applicable Not Applicable C bit (na) Not Applicable Not Applicable D bit (na) Not Applicable Not Applicable From DFXS to QJET CAS Bit Forced Normal Forced Inverted A bit (off hook) Sets the CAS A bit to 1 Idle state to E1 port Sets the CAS A bit to 0 Off hook state to E1 port  16. Click Apply to apply changes or Reset to restore the previous configuration.
128  |  Configuring the Traffic Interfaces   Aprisa XE User Manual  QV24 Serial Interface Card There  are  two  modes  of  operation  of  the  QV24  Serial  Interface  Card;  QV24  asynchronous  and  QV24S synchronous. The mode is changed with the Slot Summary.  Changing the QV24 mode changes all four ports on the interface card.  To change the QV24 mode: 1. Select Link or Local or Remote > Interface > Slot Summary, then select the QV24 interface slot and click Configure Slot.    2. Select the QV24 mode required with Expected.    3. Select the QV24 mode required with Change Type To and click Apply. 4. Reboot the terminal with a Hard Reboot (see ‘Rebooting the Terminal’ on page 233).
 Configuring the Traffic Interfaces  |  129  Aprisa XE User Manual  QV24 Port Settings A QV24 interface is always configured as a DCE. 1. Select Link or Local or Remote > Interface > Interface Summary, then select the QV24 interface and click Configure Interface.    2. Select the QV24 port to configure, and click Edit.    'Slot' shows the slot the QV24 interface card is plugged into in the terminal. 'Port' shows the interface port number (1-4). ‘Baud Rate’ shows the current baud rate assigned to the port by the cross connect. ‘Loopback’ loops back the port data to the customer (default is no loopback).  3. Set the number of Data Bits (default is 8 bits).  4. Set the number of Stop Bits (default is 1 bit).  5. Set the number of Parity Bits (default is 0 bits).   6. Click Apply to apply changes or Reset to restore the previous configuration.  Tip: The Quick Links box provides links to other related pages.
130  |  Configuring the Traffic Interfaces   Aprisa XE User Manual  QV24S Port Settings  There are two modes of operation of the QV24S synchronous, synchronous and over sampling modes. A QV24S interface is always configured as a DCE.  Synchronous Mode In synchronous mode, interface data is synchronously mapped to radio capacity using proprietary subrate multiplexing. QV24S interfaces are required at both ends of the circuit.  1. Select Link or Local or Remote > Interface > Interface Summary, then select the QV24S interface and click Configure Interface.    2. Select the QV24S port to configure, and click Edit.    'Slot' shows the slot the QV24S interface card is plugged into in the terminal. 'Port' shows the interface port number (1-4). ‘Baud Rate’ shows the current baud rate assigned to the port by the cross connect.
 Configuring the Traffic Interfaces  |  131  Aprisa XE User Manual  3. The CTS Source defines the mode in which the CTS signal responds to the remote DTE. Three options are available:  CTS Source Function Remote RTS The local CTS follows the remote RTS signal. In the case of radio link failure (when cross connected over the link) the signal goes to OFF. Local RTS The local CTS signal follows the local RTS. The status of the link does not impact on the CTS signal. On Permanent The local CTS is in a permanent ON (+ve) state. This does not go to OFF if the link fails.  Note that the CTS behaviour is not impacted by the operation of the card loopbacks.  4. The Sample Data On defines the received clock edge on which the received data is clocked into the port. Two options are available:  Sample Data On Function Falling Clock Edge The falling edge of the XTXC is used to clock data into the port. Rising Clock Edge The rising edge of the XTXC is used to clock data into the port.  5. ‘Loopback’ loops back the port data to the customer (default is no loopback).   6. Click Apply to apply changes or Reset to restore the previous configuration.  Over Sampling Mode  In over sampling mode, 64 kbit/s of radio capacity is allocated to the circuit and the incoming interface data is sampled at a fixed 64 kHz. This timeslot can be cross connected to an E1 or T1. This over sampling mode can be operated up to 19.2 kbit/s. There will be some unavoidable distortion in mark space ratios (jitter) of the transported V.24 circuit. This effect  will become  progressively more  significant  as  the  baud rate of  the V.24  circuit  increases or  the number of data conversions increases. In over sampling mode, the DTE clock input is not used and there is no DCE output clock available. 1.  Select Link or Local or Remote > Interface > Interface Summary, then select the QV24S interface and click Configure Interface.
132  |  Configuring the Traffic Interfaces   Aprisa XE User Manual  2.  Select the QV24S port to configure, and click Edit.    'Slot' shows the slot the QV24S interface card is plugged into in the terminal. 'Port' shows the interface port number (1-4). A  Baud  Rate  of  ‘OVRSAMP’  indicates  that  the  QV24S  has  been  configured  for  synchronous  over sampling mode in the Cross Connections application.  3.  The CTS Source defines the mode in which the CTS signal responds to the remote DTE. Two options are available:  CTS Source Function Local RTS The local CTS signal follows the local RTS. The status of the link does not impact on the CTS signal. On Permanent The local CTS is in a permanent ON (+ve) state. This does not go to OFF if the link fails.  Note that the CTS behaviour is not impacted by the operation of the card loopbacks.  4.  The Sample Data On defines the received clock edge on which the received data is clocked into the port. Two options are available:  Sample Data On Function Falling Clock Edge The falling edge of the XTXC is used to clock data into the port. Rising Clock Edge The rising edge of the XTXC is used to clock data into the port.  5.   ‘Loopback’ loops back the port data to the customer (default is no loopback).   6.  Click Apply to apply changes or Reset to restore the previous configuration.
 Configuring the Traffic Interfaces  |  133  Aprisa XE User Manual  HSS Port Settings 1. Select  Link  or  Local  or  Remote  >  Interface  >  Interface  Summary,  then  select  HSS  (High-speed Synchronous Serial) interface and click Configure Interface.     'Slot' shows the slot the HSS interface card is plugged into in the terminal (A – H). 'Mode'  shows  the interface  mode  provided by the  HSS  interface  (either  DTE  or  DCE).  If  there  is  no interface cable plugged into the HSS port, the ‘Mode’ will show ‘No Cable’. 'Serial  Mode'  shows  interface  type  provided  by  the  HSS  interface  (X.21,  V.35  etc).  If  there  is  no interface cable plugged into the HSS port, the ‘Serial Mode’ will show ‘None’. ‘Baud Rate (kbit/s)’ shows the current baud rate assigned to the port by the cross connect. ‘Loopback’ loops back the port data to the customer (default is no loopback). ‘Synchronous  Clock  Selection’  shows  the  current  clocking  mode  assigned  to  the  port  by  the  cross connect.  2. Set the HSS RTS CTS Mode as required.  The RTS CTS mode controls the state of the outgoing interface RTS CTS control line. When the HSS interface is DCE, the outgoing control line is CTS.  When the HSS interface is DTE, the outgoing control line is RTS.  Note: Refer to ‘HSS Handshaking and Clocking’ on page 135 for additional information on setting the recommended handshaking mode for each application.  3. Set the HSS DSR DTR Mode as required.  The DSR DTR mode controls the state of the outgoing interface DSR DTR control line. When the HSS interface is DCE, the outgoing control line is DSR. When the HSS interface is DTE, the outgoing control line is DTR.
134  |  Configuring the Traffic Interfaces   Aprisa XE User Manual  4. Set the HSS DCD Mode as required. The DCD mode controls the state of the outgoing interface DCD control line. This setting is only relevant if the HSS interface is DCE.   5. Enable or disable the HSS XTxC control, as required.  Depending on the clocking mode (see ‘HSS Handshaking and Clocking’ on page 135) selected, altering this setting will allow the terminal clock to be substituted for the external XTxC signal.   6. Click Apply to apply changes or Reset to restore the previous configuration.
 Configuring the Traffic Interfaces  |  135  Aprisa XE User Manual  HSS Handshaking and Clocking Modes This section provides detailed information on selecting the recommended  HSS handshaking and clocking modes for the HSS interface card (see ‘HSS port settings’ on page 133).  HSS Handshaking and Control Line Function HSS X.21 Compatibility In general X.21 usage, the C and I wires function as handshaking lines analogous to RTS/CTS handshakes. For switched carrier applications, the I wire is used to emulate carrier indications (DCD) function. HSS RTS / CTS Mode Set  the  RTS  CTS  Mode  as  required  according  to  the  table  below.  This  field  controls  the  state  of  the outgoing interface control line.   When the HSS interface is DCE, the outgoing control line is CTS.  When the HSS interface is DTE, the outgoing control line is RTS.  RTS CTS Mode HSS as a DCE HSS as a DTE Comment Always Off CTS driven to off state RTS driven to off state  Always On CTS driven to on state RTS driven to on state  Follows Carrier CTS follows the state of the RF link RTS follows the state of the RF link To follow carrier is to indicate the state of synchronization of the RF link Follows Carrier + Remote RTS/CTS CTS follows the state of the RF link and the remote terminal RTS input control line if the remote is a DCE. If the remote HSS is a DTE, then CTS follows the state of the RF link and the remote HSS CTS input. RTS follows the state of the RF link and the remote terminal RTS input control line. The remote HSS can only be a DCE. Control line pass-through mode where RTS and CTS are carried over the link from end to end. The carrier (as above) plus the remote terminal input control line must be present to output the local control line signal. The HSS Control bit in the Cross Connections application must be set for the remote signalling to operate. Follows Carrier + Remote DCD  CTS follows the state of the RF link if the remote HSS is a DCE. If the remote HSS is a DTE, then CTS follows the state of the RF link and the remote HSS DCD input control line.  This setting is only applicable when the local HSS card in the local terminal is a DCE. The HSS Control bit in the Cross Connections application must be set for the remote signalling to operate.
136  |  Configuring the Traffic Interfaces   Aprisa XE User Manual  HSS DSR / DTR Mode Set  the  DSR  DTR  Mode  as  required  according  to  the  table  below.  This  field  controls  the  state  of  the outgoing interface control line.   When the HSS interface is DCE, the outgoing control line is DSR   When the HSS interface is DTE, the outgoing control line is DTR  DSR DTR Mode HSS as a DCE HSS as a DTE Comment Always Off DSR driven to off state DTR driven to off state  Always On DSR driven to on state DTR driven to on state  Follows Carrier DSR follows the state of the RF link DTR follows the state of the RF link To follow carrier is to indicate the state of synchronization of the RF link. Follows Carrier + Remote DSR/DTR DSR follows the state of the RF link and the remote terminal DSR control line if the remote terminal is a DTE, or the remote DTR if the remote terminal is a DCE. DTR follows the state of the RF link and the remote terminal DTR control line if the remote terminal is a DCE. The remote HSS can only be a DCE. Control line pass-through mode where DSR and DTR are carried over the link from end to end. The carrier (as above) plus the remote terminal input control line must be present to output the local control line signal. The HSS Control bit in the Cross Connections application must be set for the remote signalling to operate.
 Configuring the Traffic Interfaces  |  137  Aprisa XE User Manual  HSS DCD Mode Set the DCD Mode as required according to the table below. This setting is only relevant in DCE mode.  DCD Mode HSS as a DCE HSS as a DTE Comment Always Off DCD driven to off state NOT applicable  Always On DCD driven to on state  Follows Carrier + Remote DCD DCD follows the state of the RF link and the remote terminal DCD input control line if the remote HSS is a DTE. If the remote terminal is a DCE, then DCD only follows the state of the RF link. Control line pass-through mode where DCD is carried over the link from end to end. The carrier (as above) plus the remote terminal input control line must be present to output the local control line signal. The HSS Control bit in the Cross Connections application must be set for the remote signalling to operate. Follows Carrier + Remote RTS  DCD follows the state of the RF link and the remote terminal RTS input control line when the remote HSS is a DCE. For switched carrier applications this provides RTS-DCD pass through (DCE to DCE configuration) and DCD-DCD pass-through (DTE to DCE configuration).  Set the XTxC Enabled control as required. Depending on the synchronous clock selection mode selected, disabling XTxC will allow the terminal clock to be substituted for the external XTxC signal.
138  |  Configuring the Traffic Interfaces   Aprisa XE User Manual  HSS Synchronous Clock Selection Modes The  following  section  describes  in  detail  each  of  the  recommended  HSS  Synchronous  Clock  Selection modes for both DTE to DCE and DCE to DCE modes of operation.  The  HSS  clocking  can  be  configured for  clocking  types  of  Internal  clocking,  pass-through  clocking,  and primary / secondary master clocking. The topology of the client network determines the clock mode that is used.  Note: Modes 3 and 4 provide only physical layer support, not X.21 protocol support.  Terminal 1 HSS as a DTE and terminal 2 HSS as a DCE - ‘Pipe Mode’  Mode Synchronous Clock Selection mode Clocking Type 0 Internal Clocks – No overhead Not supported 1 RxC + XTxC – 40 kbit/s overhead Not supported 2 RxC + TxC – 56 kbit/s overhead Pass-through clocking 3 RxC (X.21) – 40 kbit/s overhead Pass-through clocking (X.21 only) 4 RxC (X.21) – No overhead Not supported 5 XTxC   RxC – 40 kbit/s overhead Not supported 6 RxC   RxC – No overhead Primary/ Secondary Master clocking 7 RxC   RxC - 40 kbit/s overhead Pass-through clocking  Terminal 1 HSS as a DCE and terminal 2 HSS as a DCE - ‘Cloud Mode’  Mode Synchronous Clock Selection mode Clocking Type 0 Internal Clocks – No overhead Internal clocking 1 RxC + XTxC– 40 kbit/s overhead Not supported 2 RxC + TxC– 56 kbit/s overhead Not supported 3 RxC (X.21) – 40 kbit/s overhead Not supported 4 RxC (X.21) – No overhead Internal clocking (X.21 only) 5 XTxC   RxC – 40 kbit/s overhead Pass-through clocking 6 RxC   RxC – No overhead Not supported 7 RxC   RxC - 40 kbit/s overhead Not supported
 Configuring the Traffic Interfaces  |  139  Aprisa XE User Manual  HSS Clocking Types HSS internal clocking Internal clocking relies on the (highly accurate) terminal system clock, that is, it does not allow for any independent clocks coming in from client equipment. For this mode, all incoming clocks must be slaved to a clock emanating from the HSS card.  HSS pass-through clocking The HSS card is capable in hardware of passing two clocks from one side of a link to the other. Passing a clock means that the difference between the client clock(s) and the terminal clock is transferred across the link continuously. Passing a single clock in each direction requires 40 kbit/s additional link overhead, passing  two  clocks  from  DTE  to  DCE  requires  56  kbit/s  overhead,  whereas  relying  on  internal  clocking requires no overhead. Network  topology  determines  if  passing  a  clock  makes  sense.  Passing  a  clock  is  used  where  a  client's incoming clock must be kept independent of the clock sourced by the HSS card. The only time it makes sense to pass two clocks is when a client DCE in one of the HSS modes provides two independent clocks, that is, the HSS is set to Clock Mode 2. Pass-through  clocking  does  not  require using the HSS  incoming  clock as  a  Primary or  Secondary master clock for the link, but does not preclude it either.  HSS primary / secondary master clocking When  implementing  an  external clock  master,  all other  interfaces in  the  terminal  and  internal  system timings are slaved to this external clock. The  remote terminal is also slaved  to  this master clock. This master clock must be within 100 ppm of the accuracy of the terminal system clock, otherwise the terminal will revert to using its internal clock. Ideally, the external clock should be much better than 100 ppm. Mode 6 is offered for those network topologies that require RxC and TxC to be locked. For example, this is useful when interworking with an Aprisa SE HSS interface.
140  |  Configuring the Traffic Interfaces   Aprisa XE User Manual  HSS Clocking DTE to DCE ‘Pipe Mode’    DTE to DCE Mode 2: RxC + TxC - 56 kbit/s overhead (Pass-through clocking) DTE clocks used DCE clocks used Clock passing Comment RxC and TxC RxC and TxC 56 kbit/s of overhead is used to transport RxC and TxC from HSS DTE to HSS DCE. This is the preferred dual external clock system. Both clocks travel in the same direction from DTE to DCE. This mode is used when it is important that the externally supplied RxC and TxC are maintained independently. This is almost only required in cascaded (that is, multi-link) networks. This mode cannot be used in conjunction with any interface conversion to / from X.21.
 Configuring the Traffic Interfaces  |  141  Aprisa XE User Manual   DTE to DCE Mode 3: RxC (X.21) - 40 kbit/s overhead (Pass-through clocking) DTE clocks used DCE clocks used Clock passing Comment RxC RxC 40 kbit/s of overhead used to transport RxC from the DTE to DCE. Preferred option for X.21.   DTE to DCE Mode 6: RxC   RxC - No overhead (Primary/ Secondary Master clocking) DTE clocks used DCE clocks used Clock passing Comment RxC and TxC RxC and TxC The DTE XTxC is derived from the RxC and is used to generate the terminal external clock. The DCE generates RxC and TxC from the terminal clock. HSS becomes the External master clock, avoiding explicit clock passing, but foregoing the use of passing a clock in either direction (Modes 1, 5). The DTE HSS card must be set as the External clock for the terminal.
142  |  Configuring the Traffic Interfaces   Aprisa XE User Manual   DTE to DCE Mode 7: RxC   RxC - 40 kbit/s overhead (Pass-through clocking) DTE clocks used DCE clocks used Clock passing Comment RxC and TxC RxC and TxC 40 kbit/s of overhead used to transfer RxC from the DTE to the DCE RxC and TxC. Receiver derived clock system.
 Configuring the Traffic Interfaces  |  143  Aprisa XE User Manual  HSS Clocking DCE to DCE ‘Cloud Mode’    DCE to DCE Mode 0:  Internal clocks – No overhead (internal clocking) DCE clocks used Clock passing Comment RxC, TxC, XTxC Both RxC and TxC are derived from the terminal clock. Default setting. All clocks sourced internally. XTxC will be used if it is detected.
144  |  Configuring the Traffic Interfaces   Aprisa XE User Manual   DCE to DCE Mode 4:  RxC (X.21) - No overhead (internal clocking) DCE clocks used Clock passing Comment RxC RxC is derived from the terminal clock. Suggested for X.21 Cloud Configuration. Single clock X.21 system.   DCE to DCE Mode 5:  XTxC   RxC - 40 kbit/s overhead (Pass-through clocking) DCE clocks used Clock passing Comment RxC, TxC, XTxC  XTxC is transported to RxC and TxC in both directions
 Cross Connections  |  145   10. Cross Connections Embedded Cross Connect Switch The embedded cross-connect switch distributes capacity to each of the interfaces. Traffic can  be  distributed  to  any of  the  possible  32  interface  ports  as  well  as  the  integrated  Ethernet interface. This  provides the flexibility to reconfigure traffic as the network demand changes, or groom user traffic onto E1 / T1 bearers between equipment. The  maximum  number  of  simultaneous  cross  connections  per  terminal  is  256.  During  cross  connection activation, a progress bar shows the number of ports that have activated.  Link Capacity Utilization Cross connections are able to utilize all of the available capacity of the link on lower capacity radio links (<  2048  kbit/s  gross  capacity,  i.e.  up  to  500  kHz,  16  QAM).    However,  as  higher  capacity  radio  links allocate  bandwidth  for  E1  /  T1  timeslot  connections  on  64  kbit/s  boundaries,  some  capacity  may  be unusable (< 64 kbit/s).  The Cross Connections Application The Cross Connections application is a software application that is used to:  manage the cross connections switches within the terminals  create cross connections between the traffic interface ports within one terminal or between the near end and far end terminals via the radio bearer  create  cross  connections  between  symmetrical  traffic  interface  ports  with  the  symmetrical connection wizard  get the current cross connection configuration from the terminal  send and activate the cross connection configuration  save and load configuration files  The Cross Connections System Requirements The Cross Connections application requires the following minimum PC requirements:  1024 x 768 screen resolution  Ethernet interface  Java Virtual Machine
146  |  Cross Connections   Aprisa XE User Manual  Installing the Cross Connections Application The  Cross  Connections  application  is  usually  started  directly  from  SuperVisor  without  the  need  for installation. However,  if  you  want  to  use  the  Cross  Connections  application  offline  (without  any  connection  to  the terminals), you can install it on your PC. Working offline enables you to simulate new cards or terminal capacities.  The  cross  connections  can  then  be  configured  and  the resulting  configuration file  saved for later deployment. To install the Cross Connections application on your PC, navigate to the Cross Connect  directory on the supplied CD and copy the application (ccapp_exe_x_x_x.jar where x is the version) to a suitable place on your PC hard disk. Your PC 'File Types' must associate a *.jar file with the Executable Jar File so that when the *.jar file is clicked on (or double clicked on), it will be executed with Javaw.exe. If clicking on (or double clicking on) the jar file does not bring up the Cross Connections application, the 'File Types' needs to be setup in your PC.   Go to 'My Computer / Tools / Folder Options / File Types’ and click 'New'.  Type 'Jar' in the 'File Extension' box and click OK.  Click 'Change' and 'Select a program from a list'  Select 'Javaw.exe' and click OK.   Opening the Cross Connections Application To open the Cross Connections application from within SuperVisor: Select Link > Interface > Cross Connections  To open the Cross Connections application without SuperVisor: Navigate to the installed cross connections application file C-capp_exe_8_6_7.jar and double click on it.  Note: This  assumes that you have copied the cross connections application to your PC so you can work offline (without any connection to the terminals).
 Cross Connections  |  147   The Cross Connections Page The  Cross  Connections  page  is  split  into  two  panes  with  each  pane  displaying  one  terminal.  The  local terminal is displayed in the left pane and the remote terminal is displayed in the right pane. The local terminal is defined as the terminal that SuperVisor is logged into (not necessarily the near end terminal). The cards displayed depend on the type of cards and where they are inserted in the chassis.  To view all the ports for each interface card, click on the expand all ports button   .    Tool Tips are available by holding the mouse pointer over objects on the screen.  Total Assigned Link Capacity The  current  total  assigned  capacity  (radio  link  and  drop  and  insert)  is  shown  (in  kbit/s)  beside  the terminal name and IP address:
148  |  Cross Connections   Aprisa XE User Manual  Radio Link and Local Drop And Insert Capacity At the bottom of the Cross Connections  page, the capacity pane displays the Radio  and  Local  drop and insert capacities for both the local and remote terminals.    The Radio Capacity field shows the available radio link capacity (6032 kbit/s shown) and the shaded bar graph  shows  the  capacity  used  for  cross  connections  over  the  radio  link  (2600  kbit/s)  between  the terminals as a percentage of the total capacity of the radio link (30 % used). The total capacity of the radio link is determined by the channel size and the modulation type of the radio link.  The Local Capacity field shows the available capacity for local or drop and insert cross connections (52392 kbit/s shown) and the shaded bar graph shows the capacity used for local cross connections (4512 kbit/s) as a percentage of the total local capacity  (7 % used). The total local capacity is 65536 kbit/s minus the used radio capacity.  Tool tip messages show the breakdown of the radio and local capacity usage: The following is an example of the messages shown: Radio Capacity   Radio Bandwidth Usage (over the air)   8632 kbit/s total  2600 kbit/s used (30%) of total radio capacity   6032 kbit/s free  Local Capacity   Local capacity usage (for connecting ports on the same terminal)   65536 kbit/s total   8632 kbit/s reserved for radio (13%) of total local capacity   4512 kbit/s used for local (7%) of total local capacity  52392 kbit/s free  Tip: On a screen set to 1024 by 768 resolution, this capacity information may be obscured by the task bar if the Windows task bar is docked at the bottom of the screen. To view the capacity pane clearly, either shift the task bar to another screen edge, make it auto-hide, or increase the screen resolution.
 Cross Connections  |  149   Cross Connections Toolbar The cross connections toolbar has buttons for commonly-used functions. Button Explanation  Saves the cross connection configuration file to disk. The button turns amber when you have made changes that have not yet been saved.  Gets the cross connection configuration from the local and remote terminals.  Saves the cross connection configuration to the local and remote terminals. The button turns amber when you have made changes that have not yet been sent to the terminal.  Activates the cross connections on the local and remote terminals. Turns amber when there are cross connections that have been sent but not yet activated.  Expands all the ports for all the interface cards.  Collapses all the ports for all the interface cards.  Opens the symmetrical connections wizard.  Setting the Terminal's IP Address If  the  Cross  Connections  application  is  launched  from  SuperVisor,  the  terminal  IP  addresses  are  set automatically by SuperVisor, but if the application is launched from your PC independent of SuperVisor, you  will need  to  set  the  application  Local  and  Remote IP  addresses  to  the  addresses of the  Local  and Remote terminals you wish to connect to.  To set the application local or remote IP address: 1. Right-click over the terminal name or IP address and select Set Address.    2. Select Local or Remote > Set Address  3. Enter the IP address of the terminal in the dialog box and click OK.
150  |  Cross Connections   Aprisa XE User Manual  Management and User Ethernet Capacity  The maximum ethernet capacity of an Aprisa XE terminal is dependant on the motherboard version:  Motherboard Version Maximum Ethernet Capacity Rev C 32768 kbit/s Rev D 49152 kbit/s  The maximum ethernet capacity available is the lesser of the maximum ethernet capacity or the available radio link capacity.  The management ethernet capacity and user ethernet capacity must be identical on both terminals for the ethernet link to work correctly.  Management Ethernet Capacity A  management  ethernet  cross  connection  between  the  local  and  remote  terminals  is  created automatically  using  the  default  capacity  of  64  kbit/s    (connection  number  =  1).  This  connection  is essential for remote terminal management communication. The  minimum  management  ethernet  capacity  requirement  for  correct  management operation  over  the radio link  is 8 kbit/s  but if the terminal in  on  a  network with large numbers of  broadcast packets,  the management may not be able to function. The management capacity must be set in multiples of 8 kbit/s and the maximum assignable is 64 kbit/s.  User Ethernet Capacity A user ethernet cross connection between the local and remote terminals is created automatically using the default capacity of 0 kbit/s (connection number = 2). The user ethernet capacity must be set in multiples of 8 kbit/s. The  maximum user  ethernet  capacity  available  is  the  maximum  ethernet  capacity  available  minus  the management ethernet capacity setting.  To set the management ethernet or the user ethernet capacity:    Enter the  required kbit/s in the local terminal capacity field. The  associated remote terminal capacity field will update automatically. The red numbers, in the mapping connection boxes, are known as connection numbers and are allocated automatically by the Cross Connections application.
 Cross Connections  |  151   Setting Card Types  Note: You only need to do this when creating configurations offline (that is, there is no connection to the terminal).  When  you  are  connected  to  the  terminal,  the  Cross  Connections  application  automatically detects the card types fitted in the terminal slots. You can specify the card type for any of the slots (A-H).  1. Right-click a slot.    2. Select Card Type and then select the interface card.  Getting Cross Connection Configuration from the Terminals You can get the entire existing cross connection configuration from the terminals.   1. Download the existing cross connections (if any) from the local and remote terminals by clicking ‘Get cross connection configuration from terminal’.
152  |  Cross Connections   Aprisa XE User Manual  Creating Cross Connections Point to point cross connections  Three examples of point to point cross connections are shown below: Example 1 One 2 wire DFXO interface on the near end terminal slot E port 1 is cross connected via the radio link to a 2 wire DFXS on the far end terminal slot E port 1. This cross connection includes the four bits of signalling (ABCD bits) but as the DFXO / DFXS signalling is configured for 'multiplexed', the four bits are multiplexed into one bit over the radio link. This cross connection uses 72 kbit/s of radio link capacity, 64 kbit/s for the voice and 8 kbit/s for the signalling bit. The port 2s of the same DFXO / DFXS cards are cross connected using the same method.
 Cross Connections  |  153   Example 2 One 2 wire DFXS interface on the near end terminal slot E port 1 is cross connected via the radio link to a framed E1 on the far end terminal slot D port 1 in timeslot 1. This cross connection includes four bits of signalling  as  the  DFXS  signalling  is  configured  as  'non-multiplexed  signalling'  (ABCD  bits).  This  cross connection uses 96 kbit/s of radio link capacity, 64 kbit/s for the voice and 32 kbit/s for the signalling bits.  Another 2 wire DFXS interface on the near end terminal slot F port 1 is cross connected via the radio link to a framed E1 on the far end terminal slot D port 1 in timeslot 2. This cross connection includes one bit of signalling  as  the  DFXS  signalling  is  configured  in  '4  wire  compatible'  mode  (A  bit  only).  This  cross connection  uses  40  kbit/s  of  radio  link  capacity,  32  kbit/s  for  the  ADPCM  voice  and  8  kbit/s  for  the signalling bit.    Example 3 One 2 wire DFXS interface on the near end terminal slot E port 1 is cross connected via the radio link to a framed E1 on the far end terminal slot D port 1 in timeslot 1. This cross connection includes one bit of signalling  as  the  DFXS  signalling  is  configured  as  'multiplexed'  signalling.  This  cross  connection  uses 72 kbit/s of radio link capacity, 64 kbit/s for the voice and 8 kbit/s for the signalling bit.
154  |  Cross Connections   Aprisa XE User Manual  Local Drop and Insert Cross Connections   An example of a local drop and insert cross connection is shown below:  Two 4 wire E&M interfaces on the near end terminal slot C ports 3 & 4 are dropped out of a framed E1 on the near end terminal slot D port 1 in timeslots 1 & 2. This cross connection includes one bit of signalling (A bit). Another two 4 wire E&M interfaces on the near end terminal slot C ports 1 & 2 are inserted into the radio link to a framed E1 on the far end terminal slot D port 1 in timeslots 1 & 2. This cross connection includes one bit of signalling (A bit). The remaining framed E1 on the near end terminal slot D port 1 timeslots are transported over the radio link to the framed E1 on the far end terminal  slot D port  1. This  cross connection includes four bits of signalling (ABCD bits).
 Cross Connections  |  155   Sending Cross Connection Configuration to the Terminals You can send the entire cross connection configuration to the terminals.   1. To  send  the  new  cross  connection  configuration  into  the  terminals,  click  ‘Send  cross  connection configuration to terminal’.    2. When  the  transfer  is  successfully  complete,  a  message  appears  asking  if  you  want  to  activate  the configuration now.    If you click Yes, a message appears showing the activation progress.    If  you click No, you can activate  the new cross connection configuration later by clicking  ‘Activate cross connection configuration’.   Saving Cross Connection Configurations You can save the entire cross connection configuration to file so that you can restore it to the same link (if this is ever required), or transfer it to another link if you want them to be identical.  1. Click on ‘Save cross connection configuration file to disk’ or select File > Save.  2. Navigate to the directory where you want to save the file, enter the filename in the dialog box and then click Save. 3. Once you have specified a filename and a directory save any further changes by clicking Save.  Using Existing Cross Connection Configurations To load a previously-saved cross connection configuration from an existing file: 1. Select File > Open. 2. Navigate to the file and select it, and then click Open.
156  |  Cross Connections   Aprisa XE User Manual  Printing the Cross Connection Configuration You  can  print  out  a  summary  of  the  cross  connection  configuration  so  that  you  can  file  it  for  future reference. Using the printout, you can recreate the cross connection configuration. If you don't have the configuration saved to disk see ‘Saving cross connection configurations’ on page 155, or use it to review the cross connections without connecting to the terminal. The cross connection configuration summary shows information for the local and remote terminals  such as:  The IP address and terminal name  The interface card fitted in each slot  How the ports are configured    To preview the cross connection configuration summary: Select File > Preview Configuration Summary. In this dialog box you can:  Save the summary to disk (as an HTML file) by clicking Save Summary As.  Print the summary by clicking Print.  Copy  and  paste  the  information  into another  application (for example, spreadsheet,  email, and word processor) by right-clicking over the summary and selecting Select All. Then right-click over the summary again and select Copy. To print the cross connection configuration summary: Select File > Print Configuration Summary.
 Cross Connections  |  157   Deleting Cross Connections  Note: It is not possible to delete the management and user Ethernet cross connections. These are made automatically and are required for correct terminal operation.  To delete cross connections for an interface card: 1. Right-click over an interface card.    2. Select Delete All Connections on this Card.  To delete the cross connections associated with a particular port: 1. Right-click over a port.    2. Select Delete All Connections on this Port.  To delete all the cross connections for a terminal: 1. Right-click over the terminal name and IP address.    2. Select Delete All Connections on this Terminal.
158  |  Cross Connections   Aprisa XE User Manual  Configuring the Traffic Cross Connections Once you have configured the interface cards (see ‘Configuring the traffic interfaces’ on page 91), you can configure the traffic cross connections between compatible interfaces.  Compatible Interfaces Cross  connections  can  be  made  between  any  compatible  interfaces  of  equal  data  rates.  Compatible interfaces are shown in the table below:  Ethernet (management)Ethernet (user)QJET E1 UnframedQJET T1 UnframedQJET E1 Framed PCM 31QJET E1 Framed PCM 30QJET T1 SF - PTSQJET T1 SF - DMSQJET T1 ESF - PTSQJET T1 ESF - DMSQ4EM voice onlyQ4EM with E&MQV24 with signallingDFXODFXSHSS dataHSS signallingEthernet (management) Ethernet (user) QJET E1 Unframed QJET T1 Unframed QJET E1 Framed PCM 31         QJET E1 Framed PCM 30         QJET T1 SF - PTS QJET T1 SF - DMS       QJET T1 ESF - PTS QJET T1 ESF - DMS         Q4EM voice only     Q4EM with E&M       QV24 with signalling     DFXO     DFXS      HSS data     HSS signalling     
 Cross Connections  |  159   QJET Cross Connections Expand the E1 / T1 display by clicking on the relevant icons.    The  QJET  card  can  operate  in  several  modes  allowing  you  greater  flexibility  in  tailoring  or  grooming traffic. The Data type selection are Off, E1, or T1 rates.  Note:  An  unframed  E1  /  T1  port  requires  5  bits  (or  40  kbit/s)  of  overhead  traffic  per  port  for synchronization. An unframed E1 port with 2048 kbit/s of traffic requires 2088 kbit/s of link capacity. An unframed T1 port with 1544 kbit/s of traffic requires 1584 kbit/s of link capacity.
160  |  Cross Connections   Aprisa XE User Manual  For each port that you want to put into service, choose the required mode (either Unframed or Framed): Unframed Mode Leave the Framed checkbox unticked. Select the required Data type from the drop-down list E1 or T1.    Local drop and insert connections are not possible between Unframed E1 / T1 ports.  Framed Mode Tick the Framed checkbox. Select the required framed mode from the drop-down list:    Local drop and insert connections are possible between framed E1 ports on the same interface card or E1 ports on different interface cards.  Local drop and insert connections are possible between framed T1 ports on the same interface card or T1 ports on different interface cards.  Local drop and insert connections are not possible between framed E1 ports and framed T1 ports.
 Cross Connections  |  161   E1 Framed Modes  Framed Mode Description E1 – PCM 30 Provides 30 timeslots to transport traffic. Timeslot 16 carries channel associated signalling data (CAS). E1 – PCM 31 Provides 31 timeslots to transport traffic. Timeslot 16 can be used for common channel signalling or to transport traffic. E1 – PCM 30C Same as E1 – PCM 30 mode but supports CRC-4. E1 – PCM 31C Same as E1 – PCM 31 mode but supports CRC-4.  E1 CRC-4 (cyclic redundancy check) is used to ensure correct frame alignment and also used to gather E1 performance statistics e.g. Errored Seconds (ES), Severely Errored Seconds (SES).  The first three bits of timeslot 0 NFAS (bits 0,1 & 2) and all of timeslot 0 FAS are not transported  across the link, but rather terminated and regenerated at each terminal.  The  last  five  bits  of  timeslot  0  NFAS  (bits  3  –  7)  are  the  National  Use  Bits  (NUBs)  which  can  be  cross connected locally or over the link.  E1 - PCM 30 mode E1 - PCM 30 modes are used when access to the signalling bits (ABCD) is required, for example:  Splitting a PCM 30 E1 into two separate PCM 30 E1s  Cross connecting signalling from DFXS, DFXO or Q4EM interfaces into an PCM 30 E1  Drop and Insert connections between PCM 30 E1s  In PCM 30 / PCM 30C mode, the timeslot table left column is used to map timeslot bits and the timeslot table right column is used to map CAS bits (ABCD) for signalling. Timeslot 16 is reserved to transport the CAS multi frame. One use of this mode is to connect the 4 wire E&M interfaces to third-party multiplexer equipment over the E1 interface using CAS in TS16 to transport the E&M signalling. To configure this mode correctly, you must have a detailed knowledge of the CAS signalling modes for the third-party equipment to ensure the signalling bits are compatible and configured to interoperate.   E1 - PCM 31 mode E1 - PCM 31 modes are used to cross connect timeslots bits without the signalling bits (ABCD). TS16  can  be  cross  connected  between  E1  ports  (to  transport  the  entire  CAS  multi  frame)  or  used  for common channel signalling or to transport traffic. The timeslot table left column is used to map timeslot bits but the timeslot table right column for CAS bits (ABCD) is not used.
162  |  Cross Connections   Aprisa XE User Manual  T1 Framed Modes  Framed Mode Description T1 SF - PTS Provides 24 timeslots to transport traffic using the G.704 12 frame Super Frame with Pass Thru Signalling (PTS). There is no CRC capability with the SF. T1 SF - DMS Provides 24 timeslots to transport traffic using the G.704 12 frame Super Frame with DeMultiplexed Signalling  (CAS AB bits). There is no CRC capability with the SF. T1 ESF - PTS Provides 24 timeslots to transport traffic using the G.704 24 frame Extended Super Frame with Pass Thru Signalling (PTS) and CRC. T1 ESF - DMS Provides 24 timeslots to transport traffic using the G.704 24 frame Extended Super Frame with DeMultiplexed Signalling  (CAS ABCD bits) and CRC.  T1 SF - PTS mode T1 SF - PTS mode provides 24 timeslots to transport traffic using the G.704 12 frame Super Frame without demultiplexing the signalling. Pass  Thru  Signalling  provides  cross  connection  of  the  entire  framed  T1  timeslot  between  T1  ports (including the inherent robbed bit signalling). This is the most efficient method of transporting a framed T1 over the radio link as no additional radio link capacity is required to transport the signalling because the CAS is not demultiplexed.  To  maintain  multi  frame  alignment  between  two  framed  T1  ports,  a  FPS  (Frame  Pattern  Sync)  bit  is required  to  be  cross  connected  between  the  two  framed  T1  ports.  This  FPS  bit  requires  an  additional 8 kbit/s of radio link capacity.  The timeslot table left column is used to map timeslot bits but the timeslot table right column for CAS bits (ABCD) is not used.  T1 SF - PTS mode is used when access to the signalling bits is not required but are transported between T1s, for example:  Drop and Insert connections between Super Frame T1s or data interfaces  T1 SF – DMS mode T1 SF – DMS mode provides 24 timeslots to transport traffic using the G.704 12 frame Super Frame with four state demultiplexed signalling using the AB bits each with a bit rate of 333 bit/s. DeMultiplexed Signalling allows the cross connection of framed T1 ports to other interface ports e.g. to a Q4EM or HSS. An additional 8 kbit/s of radio link capacity is required to transport each CAS bit over the radio link.  The mapping left column is used to map timeslot bits and the timeslot table right column is used to map the CAS A&B bits for signalling (C&D bits are not used).  T1 SF – DMS mode is used when access to the signalling bits is required, for example:  Cross connecting signalling from a Q4EM interfaces into a 12 frame Super Framed T1.  Drop and Insert connections between Super Framed T1s or data interfaces
 Cross Connections  |  163   T1 ESF - PTS mode T1 ESF - PTS mode provides 24 timeslots to transport  traffic using the  G.704 24 frame Extended Super Frame without demultiplexing the signalling. Pass  Thru  Signalling  provides  cross  connection  of  the  entire  framed  T1  timeslot  between  T1  ports (including the inherent robbed bit signalling). This is the most efficient method of transporting a framed T1 over the radio link as no additional radio link capacity is required to transport the signalling because the CAS is not demultiplexed.  To  maintain  multi  frame  alignment  between  two  framed  T1  ports,  a  FPS  (Frame  Pattern  Sync)  bit  is required  to  be  cross  connected  between  the  two  framed  T1  ports.  This  FPS  bit  requires  an  additional 8 kbit/s of radio link capacity.    The FDL (Facility Data Link) can be cross connected between the two framed T1 ports if required. This FDL bit requires an additional 8 kbit/s of radio link capacity. The timeslot table left column is used to map timeslot bits but the timeslot table right column for CAS bits (ABCD) is not used.  T1 ESF - PTS mode is used when access to the signalling bits is not required but are transported between T1s, for example:  Drop and Insert connections between 24 frame Extended Super Framed T1s or data interfaces
164  |  Cross Connections   Aprisa XE User Manual  T1 ESF - DMS T1 ESF - DMS mode provides 24 timeslots to transport traffic using the G.704 24 frame Extended Super Frame with sixteen state demultiplexed signalling using the ABCD bits each with a bit rate of 333 bit/s. DeMultiplexed Signalling allows the cross connection of framed T1 ports to other interface ports e.g. to a Q4EM or HSS. An additional 8 kbit/s of radio link capacity is required to transport each CAS bit over the radio link.  The FDL (Facility Data Link) can be cross connected between the two framed T1 ports if required. This FDL bit requires an additional 8 kbit/s of radio link capacity. The mapping left column is used to map timeslot bits and the timeslot table right column is used to map the CAS ABCD bits for signalling.  T1 ESF - DMS mode is used when access to the signalling bits is required, for example:  Cross connecting signalling from DFXS, DFXO or Q4EM interfaces into a 24 frame Extended Super Framed T1 using ‘non-multiplexed’ signalling from the interface.  Drop and Insert connections between 24 frame Extended Super Framed T1s or data interfaces
 Cross Connections  |  165   QJET Spare CAS Bit Control The Aprisa XE can currently provide E1 CAS to DFXS circuits using the 1 bit '4 wire compatible' signalling mode (uses the CAS A bit) but to enable some exchange DTIs to operate, the state of the spare CAS bits sent to the exchange must be preset. The available CAS bits can  be preset to High  (1) or Low (0) for  the QJET framed modes  of E1 - PCM30, E1 - PCM30C, T1 SF - DMS and T1 ESF – DMS for all timeslots of the port.  To preset the spare CAS bits: Right click on the CAS bit required to be set. Select ‘Set High CAS Bit x’ or ‘Set Low CAS Bit x’.    The screen shot shows the standard configuration where the DFXS signalling using 1 bit '4 wire compatible' signalling mode is mapped to the QJET CAS A bit and the ‘spare’ CAS bits are preset to the standard 1 bit protocol spare bit pattern of BCD = 101.
166  |  Cross Connections   Aprisa XE User Manual  Selecting and Mapping Bits and Timeslots This section describes how to select and map:  a single bit  multiple bits  a 64 kbit/s timeslot  multiple timeslots  Selecting a Single Bit Each timeslot is represented by 8 rectangles (each representing a single bit). Each bit can carry 8 kbit/s. One or more consecutive bits can be selected in a timeslot if a rate of greater than 8 kbit/s is required.  1. Click on the rectangle that represents the bit you require. It will turn red.    2. Click  and  drag  this  bit  to  the  rectangle  representing  the  bit  on  the  interface  you  want  it  to  be connected to, and release the mouse button.    The red rectangle will be replaced by the allocated connection number at each interface.
 Cross Connections  |  167   Selecting Multiple Bits It is possible to select multiple consecutive bits if circuit capacity of greater than 8 kbit/s is required.  1. Click the first bit, and then hold down the Ctrl key while selecting the remaining bits.     2. Click and drag the whole block by clicking the bit on the left hand side of your selection, and drag to the required interface. Release the mouse button.   Tip: It is also possible to select multiple bits by holding down the Shift key, and dragging across the required rectangles. Differing numbers of bits display in different colors when the cross-connect is completed:
168  |  Cross Connections   Aprisa XE User Manual  Selecting a 64 kbit/s Timeslot 1. Click on the TSX timeslot number (where X is the desired timeslot from 1 to 31).    Alternatively, right-click over any of the bits in the timeslot, and click on Select Timeslot.    2. Drag and drop in the normal way to complete the cross connection.  Selecting Multiple Non Consecutive Timeslots 1. Click on one TSn timeslot number (where n is the desired timeslot 1 to 31). 2. Hold down the Ctrl key while clicking on each of the required timeslot numbers.    3. Drag and drop in the normal way to complete the cross connection.
 Cross Connections  |  169   Selecting Multiple Consecutive Timeslots 1. Click on the first TSn timeslot number (where n is the desired timeslot 1 to 31). 2. Hold down the Shift key while clicking on the last required timeslot number.    3. Drag and drop in the normal way to complete the cross connection.  Selecting All Timeslots in a Port 1. Right-click over any of the rectangles.    2. Click Select All.
170  |  Cross Connections   Aprisa XE User Manual  Q4EM Cross Connections 1. Expand the Q4EM display by clicking the relevant   icon.    2. Set the Voice capacity by selecting 16, 24, 32, or 64 kbit/s rates. 3. Drag and drop from the Voice mapping connection box to the required partner interface to create the voice cross connection. 4. If  E&M  signalling  is  required,  drag  and  drop  from  the  Signalling  mapping  connection  box  to  the required partner interface to create the E&M cross connection.
 Cross Connections  |  171   DFXS and DFXO Cross Connections 1.  On one side of the link, expand the DFXS display, as required, by clicking  .    2.  On the other side of the link, expand the corresponding DFXO display, as required, by clicking  .   3.  For the DFXS card and corresponding DFXO card, select the Signalling type as required, according to the table below. The CAS signalling between DFXO / DFXS interfaces uses 4RF proprietary allocation of control bits. The Signalling type affects both ports of the DFXO / DFXS interface. If a mixture of signalling types is required, then multiple DFXO / DFXS cards are needed.  Signalling Application Overhead Multiplexed (default) Multiplexers the four ABCD bits from the interface into a single 8 kbit/s channel. Use when interworking DFXO to DFXS, between an XE and a SE radio or when limited bandwidth is available. This signalling type cannot be used for interworking between framed E1 / T1 and voice interfaces. 8 kbit/s Non-multiplexed Transports each of the four ABCD bits in separate 8 kbit/s channels. Use when interworking DFXO to DFXS, or when signalling bits are mapped into an E1 / T1 timeslot. 32 kbit/s 4 wire compatible 1 bit CAS using only the A bit in both directions of transmission. Use when interworking the DFXS to Q4EM, DFXO to Q4EM, DFXS to DFXS or DFXS to QJET for DTI circuits. 8 kbit/s  4.  Set  the  Voice  capacity  and  create  the  Voice  connection  by  dragging  and  dropping  between  the mapping connection boxes of the DFXO and DFXS corresponding ports. 5.  Link the Port Signalling connection by dragging and dropping between the mapping connection boxes of the DFXO and DFXS corresponding ports. The DFXO / DFXS control signals (off hook, ring, etc) will not function without this connection.
172  |  Cross Connections   Aprisa XE User Manual  QV24 Cross Connections 1.  Expand the QV24 displays, as required, by clicking the relevant   icons.    2.  Select the Port Baud Rate as required (default is 9600).  3.  Drag and drop to the required partner interface to create the V.24 Data connection. If the partner interface is a QJET:  If the V.24 Baud Rate selected is 38400 is less, drag from the QV24 mapping connection box to the QJET  timeslot.  The  correct  QJET  capacity  for  the  baud  rate  selected  will  automatically  be assigned.  If the V.24 Baud Rate selected is greater than 38400, select the QJET capacity required, as per the following table, and drag from the QJET to the QV24 mapping connection box.  Baud Rate Bits Required Bit Rate 300 - 7200 2 16 kbit/s 9600 - 14400 3 24 kbit/s 19200 - 23040 4 32 kbit/s 28800 5 40 kbit/s 38400 6 48 kbit/s 57600 9 72 kbit/s 115200 16 128 kbit/s
 Cross Connections  |  173   QV24S Cross Connections Synchronous Mode 1.  Expand the QV24S displays, as required, by clicking the relevant   icons.    2.  Select the Port Baud Rate as required (default is 9600).  3.  Drag and drop to the required partner interface to create the V.24 Data connection. If the partner interface is a QJET, drag from the QV24S mapping connection box to the QJET timeslot. The correct QJET capacity for the baud rate selected will automatically be assigned.  Baud Rate Bits Required Bit Rate 300 - 4800 1 8 kbit/s 9600 2 16 kbit/s 19200 4 32 kbit/s  Over Sampling Mode 1.  Expand the QV24S displays, as required, by clicking the relevant   icons.    2. Set the Port Baud Rate to OVR Sample.  3.  Drag and drop to the required E1 / T1 partner interface to create the data connection.
174  |  Cross Connections   Aprisa XE User Manual  HSS Cross Connections 1. Expand the HSS displays, as required, by clicking the relevant   icons.    2. Select  the  Synchronous  Clock  Selection  mode  (see  ‘HSS  Synchronous  Clock  Selection  Modes’  on page 138).     3. Set the Data rate to a value between 8 and 2048 (in multiples of 8 kbit/s). The net data rate available to the user is defined by Data Rate – overhead e.g.  a  date  rate  set  to  2048  kbit/s  with  an  overhead  of  40  kbit/s  provides  a  user  data  rate  of 2008 kbit/s. 4. Drag and drop to the required partner interface to create the HSS Data connection. If  the  partner  interface  is  a  QJET,  select  the  capacity  on  the  QJET  and  drag  it  to  the  HSS  Data mapping connection box. The  QJET  capacity  selected  must  be  the  sum  of  the  data  rate  required  plus  the  overhead  rate selected.  5. Drag  and  drop  to  the  required  partner  interface  to  create  the  HSS  Signalling  cross  connection.  A minimum of 8 kbit/s of capacity is required and must be set symmetrically at both ends of the link.
 Cross Connections  |  175   Cross Connection Example This is an example of cross connection mapping:    Circuit Local port Remote port Capacity (kbit/s) Connection numbers Radio management   64 1 User Ethernet   1024 2 4 wire E&M circuit Q4EM port 1 (slot C) Q4EM port 1 (slot C) 72 7/15 Unframed E1 data QJET port 1 (slot D) QJET port 1 (slot D) 2088 65 Unframed T1 data QJET port 2 (slot D) QJET port 2 (slot D) 1584 66 2 wire loop Interface DFXO port 1 (slot E) DFXS port 1 (slot E) 72 8/32 V.24 data circuit 9600 QV24 port 1 (slot G) QV24 port 1 (slot G) 24 14 HSS data circuit 1024 kbit/s HSS port 1 (slot H) HSS port 1 (slot H) 1088 31/16
176  |  Cross Connections   Aprisa XE User Manual  Symmetrical Connection Wizard The  Cross  Connections  application  has  a  Symmetrical  Connection  Wizard  which  simplifies  the  cross connection configuration when the terminals are fitted with symmetrical / matching interface types. A symmetrical connection is a connection between the local and the remote terminal where the local slot, card type, port and connection details are identical to those of the remote terminal. The only exception is DFXO / DFXS connections where DFXO cards are considered to match DFXS cards (as they normally interwork). Framed E1 / T1 CAS connections, drop-and-insert connections, and connections that do not involve entire timeslots, are considered to be asymmetrical.  Starting the Cross Connections Wizard When starting the connection wizard with unsaved changes, the following popup dialog should appear    Click on 'Save' if you wish to save the current configuration to a file. Clicking on 'Continue' will continue with the wizard and overwrite any changes made when the wizard finishes. The wizard can be cancelled at any time by clicking on the 'Cancel' button or by closing the window.  Cross Connections Wizard Navigation Click on the Next button to progress through the connection wizard. The current stage is indicated in the navigation bar on the left. You can jump directly to a stage by clicking on the stage required.
 Cross Connections  |  177   Setting the Cross Connections IP Address If  the  local  or  remote  terminal  IP  addresses  have  been  setup, they  will  be  displayed in  the  Local  and Remote  fields.  If  the  IP  addresses  are  not  displayed,  enter  the  IP  addresses  of  the  local  and  remote terminals.   Click on 'Get Configuration' to upload the existing cross connections configuration from the local terminal. The Radio bandwidth bar will show the available bandwidth and will be updated as bandwidth is assigned to cards.  Setting the Cross Connections Bandwidth If the Cross Connections Application is opened from SuperVisor, the Total Capacity of the radio link will be shown in the Bandwidth field. If the Cross Connections Application is opened as a stand alone application, the Total Capacity of the radio link will be need to be entered in the Bandwidth field.   The  'Remove  asymmetrical  connections'  button  will  be  active  if  there  are  existing  asymmetrical  cross connections.   If you want to remove  existing  asymmetrical cross connections, click on this button. The Radio bandwidth bar will update accordingly.
178  |  Cross Connections   Aprisa XE User Manual  Cross Connections Card Selection If  the  Cross  Connections  Application  is  opened  from  SuperVisor,  existing  cards  installed  in  the  local terminal that match cards installed in the remote terminal will be displayed. Mismatched cards will be shown as 'Empty Slot'. If the Cross Connections Application is opened as a stand alone application, select the card types that will be fitted in the terminal.    To copy the card type selected in Slot A to all the other slots (B – H), click on the Copy Card button. This assumes that the same interface card types are fitted in all the card slots.
 Cross Connections  |  179   Cross Connections Interface Configurations Setup the interface configurations as per the wizard instructions. Existing asymmetrical connections will be replaced with symmetrical connections if an interface parameter is changed. Q4EM QJET   DFXO / DFXS QV24   HSS Ethernet    To copy the port configuration selected in Port 1 to all the other ports on the card, click on the Copy Port button.  To copy the card configuration to all other cards of the same type fitted in the terminal, click on the Copy Card button. This can save time when setting up multiple cards of the same type.
180  |  Cross Connections   Aprisa XE User Manual  Symmetrical Connection Summary   Click Finish.  Send Symmetrical Connection Configuration Click OK to send the configuration to the terminals.    The process is completed. Note: The wizard may change the connection numbers of existing connections.

Navigation menu